EXERCISE 1 A heat recovery problem consists of two streams given in the Table. Stream 1 2 Type Hot Cold Supply temperature (0C) 100 10 Target temperature (0C) 40 150 Enthalpy change (kW) 12 7
1 For a minimum permissible temperature difference (dTmin) of 100C,calculate the minimum hot and cold utility requirements. 2. What are the hot and cold stream pinch temperatures? 3. If the (dTmin) is increased to 200C, what will happen to the utility requirements? EXERCISE 2 The stream data for a process are given in the Table. No 1 2 3 4 5 Steam type Hot Hot Hot Cold Cold Supply temperature (0C) 160 150 140 60 60 Target temperature (0C) 40 50 110 160 150 Enthalpy change (kW) 3.6 5.0 1.5 5.0 1.8
1. Sketch the composite curves for dTmin= 100C. 2. From the composite curves, determine the target for hot and cold utility for dT min= 200C.
Answers
EXERCISE 1
1.
Stream
Type
1 2
Hot Cold
Heat Recovery
= () ( ) = 0.05 90 10 =4kW
=7 4 =3kW
=12 4 =8kW
3. When, = 20 Cold Stream curve is shifted to right side, New Cold Stream Enthalpy (kW) Temperature(C') 8.5 10 12 80 15.5 150
EXERCISE 2 1.
No
Steam type
1 2 3 4 5
T (C) Range
160-150 150-140 140-110 110-60 60-50 50-40
Hot Composite Stream Enthalpy(kW) Temperature(C) 0 40 0.3 50 1.1 60 5.1 110 9 140 9.8 150 10.1 160
Cold Composite Stream Enthalpy(kW) Temperature(C) 4.2 60 7.7 110 9.8 140 10.5 150 11 160
2.
Hot Composite Stream Temperature(C) Enthalpy(kW) 0 40 0.3 50 1.1 60 5.1 110 9 140 9.8 150 10.1 160
New Cold Composite Stream Temperature(C) Enthalpy(kW) 4.9 60 8.4 110 10.5 140 11.2 150 11.7 160