You are on page 1of 31

RRC and BRM

Company Confidential
1

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

Contents
RRC hand groups
HLP for RRC
RRC Lifetime macro
E2K for BRM

Company Confidential
2

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

RRCPRB
RRCPRB (FAM ID = 4FD) offers signalling connections towards the UE and call
control functionality. It is divided into hand groups: RRC-S, RRC-C, MCC, RRCD.
RRC-S = RRC-System = HG1
Handles system information scheduling, segment. and broadcasting
1 hand per WBTS
32 hands per ICSU
Hands 1-20 (hex)

RRC-C = RRC-Common = HG2


Handles the common RACH/FACH signaling procedures towards the UE when
there is no RRC connection
1 hand per WCEL
288 hands per ICSU
Hands 21-140 (hex)
Company Confidential
3

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

RRCPRB - MCC
MCC = MS Connection Control = HG3
Controls the connection between the UE, RNC, and CN
Requests the capacity from BRM
Produces the RLC parameters needed for radio bearer services and composes the
transport channel parameters
Controls the packet data transfer states according to inactivity/activity indications from
MAC-layer

1 hand per UE
In RN2.1: 4096 hands per ICSU
Hands 141-1140 (hex)

In RN2.2: 8192 hands per ICSU

Company Confidential
4

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

RRCPRB RRC -D
RRC-D = RRC Dedicated = HG4
Handles the dedicated signaling procedures when the UE has RRC connection i.e. it
sends/receives messages to/from the UE using Signalling Radio Bearer services of
RLC
1 hand per UE
In RN2.1: 4096 hands per ICSU
Hands 1141-2140 (hex)

In RN2.2: 8192 hands per ICSU

Company Confidential
5

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

RRC hand groups RN2.2


0000-MAN>ZSXP:RRC
ID

NAME

04FD

RRC_QX

LDT

6110 (G3106)

BP

MP

SI

18AD

32

50

0014

HGR:0001

PRC:002D

BLOCK SIZE: 01

HGR:0002

PRC:0120

BLOCK SIZE: 01

HGR:0003

PRC:2000

BLOCK SIZE: 40

HGR:0004

PRC:2000

BLOCK SIZE: 40

ZSXP:<XXX>;

Check process family ID

XXX = 3 first letters of the PRB name

Company Confidential
6

ATTR

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

HGC

0004

MQ

EH

IS

LP

HP

FFFF

01

00

50

50

FAM Family Utilities


17-FAM>?

PROCESS FAMILY HANDLING

?
F
D
I
G
H
U
M
B

.....
.....
.....
.....
.....
.....
.....
.....
.....

MENU / HELP
DISPLAY FAMILY CONTROL BLOCK (FCB)
DISPLAY FAMILY DATA BLOCK (FDB)
FAMILY INFORMATION SUMMARY
DISPLAY GROUP DATA
DISPLAY HAND DATA
DISPLAY RESOURCE USAGE
DISPLAY MINI-PCB DATA
DISPLAY TNSDL-STACK BOTTOM

K
T
R
S
C
X
A

.....
.....
.....
.....
.....
.....
.....

FREE A HAND PROCESS


SET THERMOMETER SUPERVISOR
RESET SYNC STATUS
SET SYNC STATUS
CHANGE WAITING TIMES
FORCE MASTER TO RUN
DISPLAY/MODIFY PROCESS CLEANUP DATA

Z ..... RETURN TO MAIN LEVEL


Company Confidential
7

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

FAM Family Utilities


001C-FAM>HR:4FD
RESERVED HANDS:
HAND FO:PREV NEXT
0001 00 0605 0002
0002 00 0001 0021
0021 00 0002 0022
0022 00 0021 0023
0023 00 0022 0024
0024 00 0023 0025
0025 00 0024 0026
0026 00 0025 15D2
05D2 00 15D2 1603
0603 00 1603 1604
0604 00 1604 1605
0605 00 1605 0001
15D2 00 0026 05D2
1603 00 05D2 0603
1604 00 0603 0604
1605 00 0604 0605

TIME
80003657
80003664
80003D38
80003D72
80003D8B
80003DC2
80003DDC
80003E17
806ED5AD
8073BADC
8073CA24
8073FA5C
806ED5AD
8073BADC
8073CA24
8073FA5C

GR
01
01
02
02
02
02
02
02
03
03
03
03
04
04
04
04

Company Confidential
8

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

STATE
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved

STABITS
----------------------------------------------------------------------------------L------------------------------

JBUFFER
RCOMP
0000.00000000 0000
0000.00000000 0000
0000.00000000 0000
0000.00000000 0000
0000.00000000 0000
0000.00000000 0000
0000.00000000 0000
0000.00000000 0000
0000.00000000 0000
0000.00000000 0000
0000.00000000 0000
0000.00000000 0000
0000.00000000 0000
0000.00000000 0000
0000.00000000 0000
0000.00000000 0000

FAM
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000

PROC
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000

FO
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00

Check RRC-C macro


Outputs RRC-C Cell IDs, ICSU logical addresses of working cells and RRC-C hand identifiers

wcell
wcell
wcell
wcell
wcell
wcell
wcell
wcell
wcell
wcell
wcell
wcell
wcell
wcell
wcell

ICSU
CELL ID
LOG ADD
000110 rrc-c 4450 04FD
000210 rrc-c 0000 04FD
000001 rrc-c 4452 04FD
000002 rrc-c 0000 04FD
000003 rrc-c 0000 04FD
000013 rrc-c 0000 04FD
000004 rrc-c 4453 04FD
000005 rrc-c 4453 04FD
000006 rrc-c 4453 04FD
000007 rrc-c 0000 04FD
000008 rrc-c 0000 04FD
000009 rrc-c 4453 04FD
000041 rrc-c 4452 04FD
000051 rrc-c 4452 04FD
000061 rrc-c 0000 04FD

Company Confidential
9

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

RRC-C
HAND ID
001C
0000
004E
0000
0000
0000
0035
0038
0037
0000
0000
0034
004F
0050
0000

RRC Lifetime macro

This macro can be used to check, whether there are hanging RRC hands in the system, or to
approximate the amount of concurrent calls in the system.

1. Edit configuration of the macro

#define DEVICE_NAME "RNC2"


// enter your HIT device name here
string path = "C:\\users\\"; // the results will be stored in this directory

2. Run the macro


3. Analyse the results

Both the HIT messages window and the above given path will now contain a list of currenly running
RRCPRCs MCC and RRC-D hands in each ICSU
There is also information how long the hands have been running (in minutes)
If you can find for example a pair of MCC and RRC-D that have been running for 10000 minutes, it is pretty
sure that they are hanging
If success rate for certain ICSU (or some / all of them) is poor, it might be so that RRC hands are hanging
there
Restarting the ICSU will solve the situation
Try to collect RRC monitorings and ICSU computer logs before restarting if there is time
The amount of active RRC-D and MCC hands per ICSU is a snapshot of the amount of concurrent calls in
the system - however only near exact as each ICSU snapshot is taken separately

Company Confidential
10

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

RRC Lifetime macro - example results


ICSU 01 0197 4FD hand: current life time = 00000023 minutes
ICSU 01 1197 4FD hand: current life time = 00000023 minutes
ICSU 04 0197 4FD hand: current life time = 00000002 minutes
ICSU 04 1197 4FD hand: current life time = 00000002 minutes
ICSU 05 0197 4FD hand: current life time = 00000002 minutes
ICSU 05 1197 4FD hand: current life time = 00000002 minutes
handgroup1 count 3 handgroup2 count 3

Company Confidential
11

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

HPLRRC
You can output RRC monitoring logs with HPL in order to detect failures and
exceptions
HPL extension is located in OMU
Benefit of HPL is that is does not cause any extra load to RNC
Each ICSU saves 5 MB of monitoring continously

Company Confidential
12

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

HPLRRC main menu


0000-HPL>?

MAIN MENU OF HPLRRC SERVICE TERMINAL EXTENSION

? ..... MENU / HELP


H ..... HANGING MCC HANDS HELPER
S ..... RRC SELF MONITORING COMMANDS
Z ..... RETURN TO MAIN LEVEL

Company Confidential
13

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

HPLRRC - H
0000-HPL-H>?H

HS/HF/HR - Get state info from hanging MCC hands


to Screen/to File/Read file
Hx:(<UNIT INDEX>),N(,offset,size);
Hx:<UNIT INDEX>,Pxxx(,offset,size);
<UNIT INDEX> defines index of the destination ICSU.
If <UNIT INDEX> has not been given command will be
executed in all ICSU units in state WO-EX or SP-EX.
N
Pxxx
offset
size

:
:
:
:

MCCs hung > N minutes are shown


MCC hand process xxx is shown
hex offset to data in data segment
dec number of bytes to get

If offset/size are given, the requested data is fetched


and printed unformatted. Else pre-defined data is fetched
and printed formatted.

Company Confidential
14

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

HPLRRC - S
0000-HPL-S>?

MAIN MENU OF HPLRRC SELF MONITOR COMMANDS

?
C
I
L
M
N
S
Z

.....
.....
.....
.....
.....
.....
.....
.....

MENU / HELP
CLEAR RRC SELF MONITORING BUFFER
INTERROGATE RRC SELF MONITORING INFORMATION
LIST CONTENTS OF THE RRC SELF MONITORING BUFFER
MOVE MONITORINGS TO THE SELF MONITORING BUFFER
START RRC SELF MONITORING
STOP RRC SELF MONITORING
RETURN TO MAIN LEVEL

Company Confidential
15

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

HPLRRC - S
00-HPL-S>?M

MOVE MONITORINGS TO THE SELF MONITORING BUFFER


M:<UNIT INDEX>:<PROCESS ID>;
<UNIT INDEX> defines index of the destination ICSU.
parameter is obligatory
<PROCESS ID> defines the process which messages
will be moved to self monitoring buffer. parameter
is obligatory
00-HPL-S>M:4:0;

DESTINATION UNIT: ICSU-4


=================
Data moved to Monitoring buffer successfully
DATA COUNT IN BUFFER

: 181536

00-HPL-S>M:4:1;

Company Confidential
16

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

HPLRRC - S
L writes monitorings from WO-EX ICSUs to RUNNING/RRCTMP directory
00-HPL-S>L

DESTINATION UNIT: ICSU-0


=================
BYTES WRITTEN: 5031379
Monitorings written successfully to logfile

DESTINATION UNIT: ICSU-1


=================
BYTES WRITTEN: 5013530
Monitorings written successfully to logfile
Company Confidential
17

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

RRCTMP contents
IWX::,:RRCTMP,:%,%,;

RNC

IPA2800

2005-12-15

10:40:07

VOLUME DIRECTORY.DIR: 0 INITIALIZED 01-03-27


SFFS
DIRECTORY OF RRCTMP
LIMIT 2
===============================================================
FILE NAME
FILE
FILE
DATA
PAGE
1
VERSION NO
LENGTH CREATOR ATTR
(H)
(H)
(DEC)
ICSU_0
ICSU_0
ICSU_1
ICSU_1
ICSU_2
ICSU_2
ICSU_3
ICSU_3

.LOG
.LOG
.LOG
.LOG
.LOG
.LOG
.LOG
.LOG

2
1
2
1
2
1
2
1

3
4
6
7
9
A
C
13

TOTALS

5031380
5031380
5013531
5013531
4910299
4910299
4931773
4931773

EE
EE
EE
EE
EE
EE
EE
EE

39778062 ( INCLUDING FIDS )

FREE BLOCKS IN DISK 23238444


DISK SIZE 33697119 BLOCKS

68 % )

Company Confidential
18

2005 Nokia

DA
A
DA
A
DA
A
DA
A

RRC and BRM.ppt / 2006-12-20 / MNi

FTP RRCTMP contents to you PC

Company Confidential
19

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

BRMPRB - BTS Resource Manager


FAM ID = 4FB
Load Control, Admission Control, Packet Scheduler
Receives cell specific radio resource measurement reports from BTS. Based on these
reports BRMPRB is able to schedule the remaining radio resources for various kinds of
radio access bearers of UE
Radio resource scheduling function includes the power change estimation, admission
decision and allocation of capacity, DL code and DL power for the RAB
There is 1 BRMPRB hand for each BTS and it is created when the BTS is created
There are 30 BRMPRB hands per ICSU
Allocates and releases radio resources of the cell in radio link setup, modification or release
Allocates the common channel spreading codes
Can be monitored with E2K service terminal extension

Company Confidential
20

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

E2K
Monitors the BRM process family (L3 signalling messages)
Admission Control
Load Control
Packet Scheduler
Resource Manager

Tracing calls/cell
Code trees

Company Confidential
21

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

E2K extension (BRM monitoring)


17-E2K>?
BRM MONITORING
?
B
C
E
M
N
O
P
R
T
Z

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

HELP / MENU
BTS SPECIFIC INFO
CELL STATUS FILE
Eb/No Table
MS STATUS FILE
NRT QUEUEING INFO
ONLINE MONITORING
RNC PARAMETERS
RT QUEUEING INFO
CODE TREE
RETURN TO MAIN LEVEL

Company Confidential
22

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

B - BTS specific info


001C-E2K>?B

B(C)(D):BTS_ID,OUTPUT_TYPE;
! ! !
!
! ! !
1 = BTS CELL ID LIST (default)
! ! !
2 = GENERAL INFO OF BTS
! ! !
3 = BTS SPECIFIC PARAMETERS
! ! !
4 = BTS CAPABILITY INFORMATION
! ! !
5 = BTS SPECIFIC OVERLOAD CONTROL CANDIDATE LISTS (EOCB)
! ! !
6 = COMMON MEAS OVER IUR INFO
! ! !
7 = OPEN IUB RELATED INFORMATION
! ! !
8 = BTS PENALTY TIMER (PIT) LISTS
! ! !
9 = BTS HSDPA RELATED INFORMATION
! ! !
10 = TEST PARAMETERS
! ! !
! ! !
! ! Selected BTS id (HEX/DEC)
! !
! D = Give BTS_ID parameter as DEC
!
C = Continuous output, interrupted by Ctrl-A or Ctrl-C

Company Confidential
23

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

B - BTS Cell Id list


17-E2K>B:3;
===============================================================================
BTS CELL ID LIST OUTPUT
2005-11-15
12:41:46.76
BTS 0003 (HEX) / 00003 (DEC)
State: NORMAL
===============================================================================
BRM_CELL_INDEX
CELL_ID(HEX) CELL_ID(DEC)
CELL STATE
-01
07EF
02031
NORMAL
-02
07F0
02032
BLOCKED
-03
07F1
02033
NORMAL
-04
0000
00000
NOT_IN_USE
-05
0000
00000
NOT_IN_USE
-06
0000
00000
NOT_IN_USE
-07
0000
00000
NOT_IN_USE
-08
0000
00000
NOT_IN_USE
-09
0000
00000
NOT_IN_USE
-10
0000
00000
NOT_IN_USE
-11
0000
00000
NOT_IN_USE
-12
0000
00000
NOT_IN_USE
===============================================================================
Company Confidential
24

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

C - Cell Status File


C(C)(D):BTS_ID,CELL_ID,OUTPUT_TYPE;
! ! !
!
!
! ! !
!
0 = All records (default)
! ! !
!
1 = GENERAL INFO OF CELL
! ! !
!
2 = REALTIME LOAD INFORMATION
! ! !
!
3 = RADIO NETWORK PLANNING PARAMETERS
! ! !
!
4 = LIST OF HIGH BIT RATE BEARERS
! ! !
!
5 = DECREASED BITRATE LIST
! ! !
!
6 = SCCPCH AND PCH IDs AND PARAMETERS
! ! !
!
7 = PRACH ID AND PARAMETERS
! ! !
!
8 = EXTENDED REALTIME LOAD INFORMATION OF CELL
! ! !
!
9 = OPEN IUB RELATED INFORMATION OF THE CELL
! ! !
!
10 = OVERLOAD CONTROL PRIORITY LISTS
! ! !
!
11 = OVERLOAD CONTROL CANDIDATE LISTS
! ! !
!
12 = PS REJECTION RATE INFORMATION
! ! !
!
13 = SLHO CELL INFORMATION
! ! !
!
14 = SLHO CANDIDATE LISTS
! ! !
!
15 = SLHO INTERFERENCE LOAD INFO
! ! !
!
16 = SLHO PS NRT CAPA REQ REJECTION RATE LOAD INFO
! ! !
!
17 = SLHO DL SC RESERVATION RATE LOAD INFO
! ! !
!
18 = SLHO HARD BLOCKING LOAD INFO
! ! !
!
19 = HSDPA INFORMATION OF THE CELL
! ! !
!
20 = PRE-EMPTION CANDIDATE LIST
! ! !
!
! ! !
Selected CELL ID (HEX/DEC) / 0 = all / W = working

Company Confidential
25

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

C - Cell Status File


17-E2K>C:1,W,1;
===============================================================================
CELL STATUS FILE OUTPUT
2005-11-15
12:54:12.77
BTS 0001
CELL INDEX 0001
CELL ID 07DB
(HEX)
00001
0001
02011
(DEC)
===============================================================================
GENERAL INFORMATION OF CELL
===============================================================================
CODE TREE INDEX
01
PRIMARY DOWNLINK SCRAMBLING CODE
00C8
SECONDARY DOWNLINK SCRAMBLING CODE
00
MAC-C Computer ID
4470
MAC-C Family id
0513
MAC-C process ID
0000
CELL STATE
NORMAL
PRE-EMPTION ALLOWED
TRUE
PRE-EMPTION STARTED
FALSE
PRE-EMPTION STARTED OUTSIDE
FALSE
...
===============================================================================
Company Confidential
26

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

M - MS status file
M(C)(D):BTS_ID,OUTPUT_TYPE,MS_ID,CELL_ID;

HEX/DEC = Selected CELL_ID

(Parameter affects only with output_type 8)

DEC = Selected MS_ID

1 = GENERAL MS INFORMATION LIST OF CURRENT MS DATA

2 = GENERAL MS INFORMATION LIST OF NEW MS DATA

3 = DETAILED CURRENT MS SPECIFIC DATA -> Shows MCC hand and ICSU id

4 = DETAILED NEW MS SPECIFIC DATA

5 = COMPRESSED MODE RELATED DATA

6 = GENERAL DCH INFORMATION LIST OF CURRENT MS DATA

7 = GENERAL DCH INFORMATION LIST OF NEW MS DATA

8 = MS RL INFORMATION LISTED BY CELLS (CURRENT MS DATA)

9 = SLHO MS INFORMATION

Company Confidential
27

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

= All CELLs (default)

= All active MS records (default)

(default)

M - MS status file
001C-E2K>M:1;
===============================================================================
MS STATUS FILE OUTPUT
2005-12-06
21:26:52.24
BTS 0001 (HEX) / 00001 (DEC)
===============================================================================
GENERAL MS INFORMATION LIST OF CURRENT AND VALID DATA
------------------------------------------------------------------------------RL data:
MS_ID SRNTI
PID PRE SF
DCH_CNT
CNT
RL_ID CELL
SPREAD_CODE RL_PWR
-002 000018DF 0839 F
0128 04
02
01
07DD
0005
17.50
02
07DB
0006
17.50
-003 000018E2 083A F
0128 04
01
01
07DD
0004
17.50
-004 000018E0 083A F
0128 04
03
01
07DB
0005
18.00
02
07DD
0006
18.00
03
07DF
0004
18.00
-005 000018DD 0839 F
0032 02
01
01
07DD
0005
21.00
-006 000018DE 083A F
0128 04
02
01
07DD
0008
21.00
02
07DB
0004
21.00
-007 000018DB 0839 F
0032 02
02
01
07DD
0003
21.50
02
07DB
0003
21.50
===============================================================================
Company Confidential
28

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

M - MS status file
001C-E2K>M:1,6;
===============================================================================
MS STATUS FILE OUTPUT
2005-12-06
21:30:04.86
BTS 0001 (HEX) / 00001 (DEC)
===============================================================================
GENERAL DCH INFORMATION LIST OF CURRENT AND VALID DATA
------------------------------------------------------------------------------DCH_
AR_ TRAF_ TH_
MS_ID DCH TYPE
DL_BR
UL_BR
DL_STATE UL_STATE PRI CLASS PRI
-001 00
SIGNAL_LINK 00003700 00003700 ACTIVE
ACTIVE
15 CONVE 00
-001 01
PS_NRT_DATA 00032000 00032000 ACTIVE
ACTIVE
08 BACKG 00
-002 00
SIGNAL_LINK 00003700 00003700 ACTIVE
ACTIVE
15 CONVE 00
-002 01
AMR_SF_1
00012200 00012200 INACTIVE INACTIVE 14 CONVE 00
-002 02
AMR_SF_2
00012200 00012200 INACTIVE INACTIVE 00 CONVE 00
-002 03
AMR_SF_3
00012200 00012200 INACTIVE INACTIVE 00 CONVE 00
-003 00
SIGNAL_LINK 00003700 00003700 ACTIVE
ACTIVE
15 CONVE 00
-003 01
AMR_SF_1
00012200 00012200 INACTIVE INACTIVE 14 CONVE 00
-003 02
AMR_SF_2
00012200 00012200 INACTIVE INACTIVE 00 CONVE 00
-003 03
AMR_SF_3
00012200 00012200 INACTIVE INACTIVE 00 CONVE 00
-004 00
SIGNAL_LINK 00003700 00003700 ACTIVE
ACTIVE
15 CONVE 00
-004 01
AMR_SF_1
00012200 00012200 INACTIVE INACTIVE 14 CONVE 00
-004 02
AMR_SF_2
00012200 00012200 INACTIVE INACTIVE 00 CONVE 00
-004 03
AMR_SF_3
00012200 00012200 INACTIVE INACTIVE 00 CONVE 00
-005 00
SIGNAL_LINK 00003700 00003700 ACTIVE
ACTIVE
15 CONVE 00
-005 01
PS_NRT_DATA 00064000 00032000 ACTIVE
ACTIVE
08 BACKG 00
-006 00
SIGNAL_LINK 00003700 00003700 ACTIVE
ACTIVE
15 CONVE 00
-006 01
AMR_SF_1
00012200 00012200 INACTIVE INACTIVE 14 CONVE 00
-006 02
AMR_SF_2
00012200 00012200 INACTIVE INACTIVE 00 CONVE 00
-006 03
AMR_SF_3
00012200 00012200 INACTIVE INACTIVE 00 CONVE 00
-008 00
SIGNAL_LINK 00003700 00003700 ACTIVE
ACTIVE
15 CONVE 00
-008 01
PS_NRT_DATA 00064000 00032000 ACTIVE
INACTIVE 08 BACKG 00
===============================================================================

Company Confidential
29

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

T - Code Tree
T(C)(D):BTS_ID,CELL_ID,SF,SEARCH_KEY,CODE_ID/MS_ID;
! ! !
!
! !
!
! ! !
!
! !
0
= All codes (default)
! ! !
!
! !
DEC = Selected CODE_ID/MS_ID
! ! !
!
! !
(SEARCH_KEY must be 'B' or 'C')
! ! !
!
! 0 = output all codes (default)
! ! !
!
! 1 = CODE STATUS: FREE
! ! !
!
! 2 = CODE STATUS: RESERVED
! ! !
!
! 3 = CODE STATUS: OCCUPIED FROM UP
! ! !
!
! 4 = CODE STATUS: OCCUPIED FROM DOWN
! ! !
!
! 5 = CODE STATUS: NOT IN USE
! ! !
!
! 6 = CONNECTION TYPE: RT code
! ! !
!
! 7 = CONNECTION TYPE: NRT codes
! ! !
!
! 8 = CONNECTION TYPE: Common codes
! ! !
!
! 9 = CONNECTION TYPE: RT and NRT
! ! !
!
! A = CONNECTION TYPE: Signaling
! ! !
!
! B = Search code by MS_ID
! ! !
!
! C = Search code by CODE_ID
! ! !
!
Output only codes of selected spreading factor
! ! !
!
0 = ALL SF levels(default),4,8,16,32,64,128,256,512

Company Confidential
30

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

T - code tree common channels


001C-E2K>T:1,7DB,,8;
===============================================================================
CODE TREE OUTPUT
2005-12-06
21:50:03.61
BTS 0001
CELL INDEX 0001
CELL ID 07DB
(HEX)
00001
0001
02011
(DEC)
===============================================================================
Optimisation allowed
TRUE
Optimisation incomplete
FALSE
Optimisation counter
00011 / 00040
Continue optimisation from here
00000
Optimisation timer (sec)
03600
Code tree usage (%)
40
SPREADING FACTOR 64
------------------------------------------------------------------------------OCCUPATION
INDEX
SF
ID
STATUS
OC OU OD MS_ID C_DOWN C_UP
CONNECT TYPE
-0065
0064
0001 RESERV
T
F
F
0000
00000
00000 COMMON SCCPCH1
SPREADING FACTOR 256
------------------------------------------------------------------------------OCCUPATION
INDEX
SF
ID
STATUS
OC OU OD MS_ID C_DOWN C_UP
CONNECT TYPE
-0256
0256
0000 RESERV
T
F
F
0000
00000
00000 COMMON CPICH
-0257
0256
0001 RESERV
T
F
F
0000
00000
00000 COMMON PCCPCH
-0258
0256
0002 RESERV
T
F
F
0000
00000
00000 COMMON AICH
-0259
0256
0003 RESERV
T
F
F
0000
00000
00000 COMMON PICH
===============================================================================

Company Confidential
31

2005 Nokia

RRC and BRM.ppt / 2006-12-20 / MNi

You might also like