Professional Documents
Culture Documents
Issue Date
V0.2
(Draft, non-binding)
2011-03-25
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied.
Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. Please feel free to contact our local office or company headquarters.
Contents
1 Product Orientation and Feature...................................................................................... 4
1.1 Product Orientation .............................................................................................................................. 4 1.2 Product Features ................................................................................................................................... 6
Page 3 of 19
Page 4 of 19
Figure 1-1 Position of the UAP2816 on the UMTS network in Huawei uBro solution
UAP2816: UMTS AP series product BAS: Broadband access server IP Clock Server: IP clock server AP manager: UAP2816 management system centralized
UMTS AG: UMTS access gateway AHR: UAP2816 home register SeGW: security gateway DSLAM: digital subscriber line access multiplexer
The network elements (NEs) in the uBro solution and their functions are as follows: UAP2816: It incorporates the functions of the NodeB and some functions of the RNC. It performs the UMTS radio access functions such as radio signal modulation and demodulation, radio resource management, and power control. AG: Configured on the intranet of a mobile operator, it converges and manages services of the UAP2816 and also performs routing towards the UMTS CN. AP manager: It provides network management functions for the UAP2816. AHR: Configured on the intranet of a mobile operator, it stores and manages the location information and subscription information of the UAP2816. IP clock server: It provides the UAP2816 with an IP clock. Authentication, Authorization and Accounting (AAA): It performs authentication for the AP based on the EAP-AKA and EAP-SIM. Security Gateway (SeGW): It provides the IP Security Protocol (IPSec) Virtual Private Network (VPN) tunneling and standard firewall functions.
Page 5 of 19
Page 6 of 19
Handovers and cell reselection can be performed between AP cells or between an AP cell and a macro cell to ensure excellent user experience. The differentiated billing is supported. Therefore, users of different attributes can use different billing standards.
Page 7 of 19
2
2.1 Overview 2.2 Hardware Architecture
UAP2816 Body
Product Architecture
The UAP2816 has a case structure. It contains a built-in RF subsystem, baseband subsystem, transport subsystem, control subsystem, and clock subsystem. The UAP2816 is configured with two Ethernet ports and built-in RF antennas. The UAP2816 features high integration, low power consumption, small footprint, stylish appearance, and light weight.
Power Adapter
The UAP2816 supports the AC power supply function. To use the AC power supply, the ePico3801B needs to be configured with the AC/DC power adapter. The AC/DC power adapter converts the 110 V AC/220 V AC power supply to the 12 V DC power supply, which is used by the as its working power supply.
Page 9 of 19
3 Description
No.
Port or Button
Quanti ty 1 1
1 2
Power RST
This port is connected to a power adapter to provide 12 V DC power supply. This button is used to reset the device. You can press the RESET button once to restart the UAP2816 or press this button for five seconds to restore the IP address for local maintenance to 172.16.1.1. The password for logging in to the WebUI is the last eight digits of the APEI. Ethernet port for network surfing on the computer
LAN
Page 10 of 19
3
3.1 Overview
The UAP2816 provides an operation and maintenance system that supports both the web mode and the Graphical User Interface (GUI) mode. The UAP2816 supports customized human-machine interfaces. Maintenance personnel can use the AP manager to remotely manage and maintain all the UAP2816s on the network in a centralized manner, or they can locally log in to the WebUI to operate and maintain a local UAP2816. In addition, they can use the local maintenance terminal (LMT) to perform message tracing on interfaces, performance monitoring, and equipment commissioning. Figure 3-1 shows the operation and maintenance system of the UAP2816. Figure 3-1 Operation and Maintenance (OM) system of the UAP2816
Page 11 of 19
Through the AP manager, the maintenance personnel can subscribe to alarms reported by the UAP2816, query the history alarms, and query and monitor active alarms. The UAP2816 supports realtime reporting of alarms. The maintenance personnel can log in to the UAP2816 through the AP manager to view key parameter settings and alarm information, which helps handle the alarm and rectify the fault. Through the LMT, the maintenance personnel can perform interface tracing, signaling tracing, and fault diagnosis for the UAP2816 to locate faults quickly. They can also save the tracing data as files, which can be reviewed through Trace Viewer.
Page 12 of 19
4
4.1 RF Specifications
Item 3G frequency bands Capacity Maximum TX power Diversity
RX Sensitivity Noise Figure Min RF Output power Max RF Output Power RF Output adjustment steps CPICH
Technical Specifications
Specification RX band (MHz) 1920 to 1980 One carrier, one cell 13 dBm (20 mW) No TX or RX diversity
-110dBm 16dB -10dBm 13dBm 0.5dB
10%
Page 13 of 19
Page 14 of 19
Relative humidity for working: 5% RH to 95% RH Relative humidity for storage: 5% RH to 95% RH 60 m to 1800 m 70 kPa to 106 kPa EUROPEAN ETS 300 019-1-3 " Partly temperature-controlled locations" Class 3.2. EUROPEAN ETS 300 019-1-1 "Class 1.2, Weatherprotected, not temperature-controlled storage locations". EUROPEAN ETS 300 019-1-2 "Class 2.3 PUBLIC transportation".
Page 15 of 19
EMC
CISPR 22(2003): "limits and methods of measurement of radio disturbance characteristics of information". IEC61000-3-2 IEC61000-3-3 IEC61000-4-2 Electromagnetic compatibility (EMC) Part 4: Testing and measurement techniques Section 2: Electrostatic discharge immunity test Basic EMC Publication. IEC61000-4-3 Electromagnetic compatibility; basic immunity standard: radiated, radio frequency electromagnetic fields; immunity test. IEC61000-4-4 Electromagnetic compatibility (EMC) Part 4: Testing and measurement techniques Section 4: Electrical fast transient/burst immunity test Basic EMC publication. IEC61000-4-5 Electromagnetic compatibility (EMC) Part 4: Testing and measurement techniques Section 5: Surge immunity test. IEC61000-4-11 Electromagnetic compatibility (EMC) Part 4: Testing and measurement techniques Section 11: Voltage dips, short interruptions and voltage variations immunity. EN301 908-1
Page 16 of 19
Alternating Current Access Gateway Access Point AP Home Register Adaptive Multi-Rate Authentication and Key Agreement Broadband Access Server Digital Subscriber Line Access Multiplexer Extensible Authentication Protocol Electro Magnetic Compatibility Fast Ethernet GateWay Graphic User Interface High Speed Packet Access Internet Protocol Internet Key Exchange Local Maintenance Terminal Mean Time Between Failures Power over Ethernet Power Sourcing Equipment Relative Humidity Security GateWay
Huawei Proprietary and Confidential Page 17 of 19
PSE RH SeGW
Issue V0.2 (2011-03-25) (Draft, non-binding)
Subscriber Identity Module UMTS Subscriber Identity Module Small Office and Home Office Small and Medium Enterprise x Digital Subscriber Line
User Equipment
Page 18 of 19
Please click one of the following options to provide your feedback on this document: Very good Good Ordinary Bad