Professional Documents
Culture Documents
In line with our ISO 9000 accreditation, only those products that meet the highest quality criteria have been included.
NEW - Look out for the new products now available from the UK Letchworth warehouse including the range of newly CE marked,
UL/FM Approved, TFX range of addressable fire panels. Other new products include I.S. Barriers, Water Leak Detection equipment,
Callpoint STOPPERS and much more. A separate catalogue for Tyco MX Technology will be available shortly.
Our warehouse is one of the largest Fire & Security product distribution centres in
Europe. Our goal is to despatch product on the same day as we receive your order.
Our warranty and service returns policy is second to none. We recognise that your
business is highly dependant on excellence in customer service and to help achieve
this we offer extended warranty from many of our suppliers. Full credit is also
available on a “No Question – No Fuss” basis for any new in-warranty product
returned to the distribution centre.
Our training department offers comprehensive sales, design and engineering training on
our complete range of products. We recommend you take advantage of this free of charge
service. As always, training can be undertaken any time, anywhere to suit your business
needs. Contact our telephone Help Line for further information.
NEW - The website now includes a whole section for CAD Operators
including Standard Symbols, Drawings and Schematics for products in this
catalogue.
For further details on this catalogue, contact our customer telephone Help Line on
+44 1932 74 3327.
NEW - Now including Product Code Index, Cross Reference to Approvals, Cross
Reference to Technical Publications and Datasheets, CAD Symbol Index and much more.
Page 1
tyco Fire & Tyco Electronic
Security Product Group
Table of Contents
Page 2
tyco Fire & Tyco Electronic
Security Product Group
Addressable Fire Systems - LPCB Approved
ThornGraph
reduces configuration time, increases the integrity ThornNet will support up to a maximum of 3
of information and enables simple updates to the ThornGraph user interfaces on the network.
system in the future. ThornGraph consists of a standard personal
Features computer, that is linked onto the ThornNet via a
TLK-530 network interface module. ThornGraph is
• Combined text and graphics display on a single
primarily operated by either mouse or touch
P.C.
screen, with three monitor options available 17",
• Connected to ThornNet, a single system can
20" or 21" touch screen.
be used to monitor up to 62 MINERVA fire
controllers. For an up to date specification of the latest
• Designed for touch screen operation approved PC platform contact the Fire Product
• Simple operator controls, no Qwerty keypad Manager.
• High resolution colour SVGA display Product Codes
• Windows NT TM multi-tasking operating system 508.020.001
• Four level automatic zoom sequence available
Introduction Compatibility tested PC for ThornGraph graphics
for each point
terminal preloaded and configured with default
ThornGraph is a combined text and graphics • Overview map maintains a view of wider areas
passwords
system which provides a window through which whilst zooming into detail in the graphics
the status of all MINERVA fire controllers window 508.020.006
connected to ThornNet can be monitored and • Procedure window provides additional text and Thorngraph 22” touchscreen - Liyama touch pro
controlled. operator instructions for each event 510 complete with 5 year warranty
ThornGraph has been designed with clear displays • Classification of events helps to maintain a 508.020.003
and simple controls which can be quickly and record of activation and the causes
ThornGraph 17 inch standard monitor
easily understood by an operator rather than an • Browse icons placed on maps can be used to
pan across an installation in a logical sequence 508.020.004
engineer. The system is designed to be used with
a touch screen or mouse and does not require the • Control icons placed on maps can be used to ThornGraph 20 inch standard monitor
use of a Qwerty keyboard. P.C. based ThornGraph initiate actions at the MINERVA fire controller, 508.020.101
uses the latest in operating system software. used to operate ancillaries such as HVAC. Software package A for 1 network node
Windows NT TM is a multi-tasking operating system • Automatic configuration using the GRAB-IT
tool, including Cad drawings, text messages, 508.020.102
providing a truly reliable platform for a real time
monitoring system using a P.C. Using the secure locations, flood fills and zoom areas Software package B for 2-5 network node 5
acknowledged transfer of events, up to three • Full password protection and multiple operator 508.020.103
ThornGraph systems can be used to monitor up to levels Software package C for 6 or more network nodes
62 MINERVA controllers connected to ThornNet. • Remote control of MINERVA fire controller
across the network using VFP, Virtual Front 508.020.104
ThornGraph uses a unique configuration tool
Panel Software package D for additional graphics nodes
GRAB-IT, (Graphical, AutoCad, Bitmap,
• Real time on line event management and on the same ThornNet
Information, Transfer) to automatically configure
the system. Installation plans, device type and historic information system
location, flood fill areas, flood fill locations, zoom • User designed search keys can be used to Datasheet - Product Code PSF80 “Thorngraph”
areas and zoom magnifications are all imported generate specific and useful reports
Manual - Vol011B “Software Operating Manual”
from AutoCad. This configuration tool significantly ThornGraph provides a graphical user interface to
the ThornNet, network communications system.
ThornGraph Typical Arrangement
Page 3
tyco Fire & Tyco Electronic
Security Product Group
ThornNet
ThornNet provides a true peer to peer processing of other panels to co-ordinate and single "seamless" system.
communications interface for up to 62, MINERVA distribute systems control. • ThornGraph, a P.C. based graphical user
8, MINERVA 16E or MINERVA 80 fire controllers • System can be configured in the field using interface, connects directly on to the network.
in any combination and the ThornGraph, graphical Consys software. • ThornNet supports combinations of MICC,
user interface. The units can be inter-connected
• Failure of one node does not affect any other twisted/shielded pair cabling, fibre optic
into a large network without the need for a host or
node or communications between nodes. In cabling, and dedicated telephone line.
master controller. ThornNet is based upon a
the event of multiple failures, nodes will • Multiple communication topologies bus or ring.
combination of hardware and software that allows
automatically re-generate into independent
MINERVA fire controllers (Nodes) to be linked The MINERVA ThornNet communications network
fully functional networks.
together. The ThornNet supports up to 61,380 is a collection of network interface modules and
analogue/addressable points, 4,960 zones and • Automatic network re-configuration when a peripheral equipment that together form a
over 7,000 digital I/0 points. The network co- previously failed node is restored to the network.
ordinates and distributes alarm annunciation and network.
Product Codes
supervises system operation. When connected to • Up to 3,000 meters between nodes with
557.180.219
the network, each MINERVA controller maintains twisted/shielded cable.
its full stand-alone features, functions and ThornGraph PC to TLK-530-G connection cable
• System will operate on standard 2 core MICC.
capabilities. 557.180.148.A
• MINERVA controllers may be grouped into
Features sub-nets where each panel is programmed to TLO/TLD housing for a combination of 2 x
• LPCB approved inter-act only with other selected controllers. TLO530 or TLD530 Communication interfaces
(ADT branded)
• A peer to peer network that does not use a • Plug-in module (TLK-530) easily connects a
host or master controller. MINERVA fire controller to the network. 557.180.148.T
• 62 nodes, 61,380 points, 4,960 zone capacity. • Data is re-generated at each MINERVA TLO/TLD housing for a combination of 2 x
controller and is sent out over the ThornNet as TLO530 or TLD530 Communication interfaces
• Virtual Front Panel (VFP) enables an operator
new clean data. All degradation in received (available Thorn branded)
to interrogate and control any MINERVA
controller from the keypad/display of any other data due to noise on a line, line attenuation, or 557.180.147
MINERVA controller. phase shifting is eliminated when the data is Spare TLK -530 firmware Version 2.36
re-generated.
• Bi-directional signaling.
• The ThornNet uses a token-passing, non
• Open/short circuit isolation. Datasheet - Product Code PSF81 “ThornNet”
collision communication protocol for data
• Open/short circuit location. transmission. Manual - Vol07A-04-D1 “Communications
• Events originating at any MINERVA controller Systems Manual”
• "Network zones" and "sectors" allow the
can be used as an input to event/action network controllers to be configured as a
TLK-530
The key hardware component that makes the
network possible is the TLK-530 module. The
TLK-530 provides the electrical/mechanical means
to connect the components of the network to local
and remote network signalling circuits. Installation
of the TLK-530 is simplified with an edge
connector that plugs onto the main processor
board of the MINERVA controller. The TLK-530
provides RS-485 communications over a twisted
shielded pair as a standard configuration. The
distance between controllers can reach 3,000 557.180.215 557.180.218
meters at a speed of 38.4 Kbs using 18AWG
TLK530 ThornNet network node interface module TLK 530G ThornNet interface for ThornGraph PC
twisted shielded cable.
(Note: Functionally the same as TFX-TLI530) c/w 240V PSU and housing
Fits within the MINERVA housing.
TLO-530
The Fibre Optics Module (TLO-530) is used to at 38.4 Kbs at distances as high as 4,000 meters
interface one fibre optic channel to the TLK-530 between controllers.
module. The TLO - 530 fibre optic interface Up to two units can be fitted into a TLO/TLD
module converts RS-485 digital data current Housing which has a chassis plate to
pulses from the TLK-530 network interface accommodate the units.
module to light pulses. The light pulses are then Technical Specification
carried over fibre optic cabling to another TLO- Dimensions: 210H x 130W x 30D mm
530 where the pulses are converted back to RS- Product Codes
485 digital data current pulses. Two TLK-530
557.180.698
modules are required per panel for redundant
TLO 530 ThornNet fibre optics interface assembly
path star connections and when using fibre optics
in both directions of ring and bus connections. 557.180.148.A
Two (2) type 62.5/125 fibres between controllers TLO/TLD Housing - ADT branded
(4 fibres when using redundant path star 557.180.148.T
connections) allow the interface to transmit signals TLO/TLD Housing - Thorn branded
TLD-530
The Telephone Line Drive Module (TLD-530) is Technical Specification
used to interface two (2) dedicated telephone line Dimensions: 170H x 120W x 20D mm
circuits to the TLK-530 module. The TLD-530 line
Product Codes
driver module converts the RS-485 signals
received from the TLK-530 network interface 557.180.699
module to signals capable of being transmitted TLD 530 ThornNet direct line driver PCB
over the telephone line circuits.One TLK-530 557.180.148.A
supports two channels so only one module is
TLO/TLD Housing - ADT branded
required per controller for both single path and
redundant path star connections. The interface 557.180.148.T
allows for field configured baud rates and TLO/TLD Housing - Thorn branded
supports distances of up 3,000 meters. Up to two
units can be fitted into a TLO/TLD Housing
Page 4
tyco Fire & Tyco Electronic
Security Product Group
MINERVA Analogue Addressable Fire Controllers
Features
• 8, 16 & 80 Zone networkable controllers
• Seamless peer to peer networking
• Full function repeaters
• LPCB Approved
• T890/891 Marine Approved variants
• NEW Mandarin option
• Loop power sounder options
• Wide range of addressable devices
• Conventional system upgrade path
• Twin microprocessor watchdog function
• Continuous and pulsing sounders
• Programmable mapping of signals for
controlled evacuation
• On-site software configuration
• Powerful cause and effect software
programming
• Remote printer, mimic and VDU options
• 500 event memory
MINERVA is a comprehensive and reliable range The controllers and ancillaries are LPCB and • Pre-alarm capability
of networkable analogue addressable fire Marine approved with various other international
• Threshold compensation for optimum detector
controllers with over 10,000 installations cross listings.
performance
worldwide. MINERVA complies with BS5839 Pt 4
and can be installed to BS5839 Pt. 1. • Detector condition monitoring advises when
detector servicing is required
Technical Specification • Weekly test reminder and walk test facility
LPCB Approved MINERVA 8 MINERVA 16E MINERVA 80 • Addressable intrinsically safe System 602
Marine Approved (Note4) - T891M T890M • Surface and flush mount options
Zones 8 16 80 Technical Specification (Excludes Marine)
Points 99 198 990 Dimensions: 320H x 440W x 140D mm
Zonal LED Display 8 16 80 Approx. Weight: 7Kg
LCD Display 80 Character 80 Character 80 Character Colour: Dawn Grey BS4800 10-A-03
Sounder Circuits (2 off) 500mA each 500mA each 500mA each Installation: Surface or Semi-flush
Alarm Relay (1 off) 30Vd.c. @1.5A 30Vd.c. @1.5A 30Vd.c. @1.5A Operating Temp: -10°C to + 55°C
Fault Relay (1 off) 30Vd.c. @1.5A 30Vd.c. @1.5A 30Vd.c. @1.5A Storage Temp: -20°C to + 65°C
Product Codes Humidity: Up to 95% RH (Non-
condensing)
Control Panel Surface Mounting 557.180.564 557.180.550 557.180.556
Housing Protection: IP43
Control Panel Flush Mounting 557.180.565 557.180.553 557.180.557
Mains Supply: 110V-120V/220V-240V a.c.
Marine Panel - 557.180.402 557.180.401
± 10% at 50/60HZ ± 5%
Repeater Panel Surface Mounting 557.180.566 557.180.554 557.180.558
Secondary Supply: 24V d.c. Nominal
Repeater Panel Flush Mounting - 557.180.555 557.180.559
NOTE: A self contained 3 amp switch mode
Marine Repeaters (T290/291) - 557.180.404 557.180.403 power supply together with 2 x 6 AH 12V or 2 x
10 AH 12V batteries may be fitted inside the main
Special Control Panel Variants - housing of the MINERVA 8 or MINERVA 16E -
Loop Powered Surface Mnt Panel Note 3 Note 3 557.180.569 (See Note 1 for battery fixing kits). The MINERVA
80 requires a separate housing for its power
Loop Powered Flush Mnt Panel Note 3 Note 3 557.180.570
supply. Batteries up to 2 x 15 AH 12V may also be
Panel with Arabic overlay - 557.180.568 557.180.567 fitted in this housing. See AC Power Module.
Panel with Dutch overlay 557.180.701 557.180.703 557.180.702
Panel with Mandarin graphics display - 557.180.575 557.180.576 Datasheet - Product Code PB56 “Minerva 8, 16,
16E, 80 Panels”
Additional Components
Manual - Vol015A-02-D1 “Minerva Range of
Note 1 : 557.180.055 MINERVA 8 and 16E battery fixing kit.
Analogue Addressable Fire Controllers”
557.180.065 MINERVA 80 battery fixing kit
557.180.410 T890 battery fitting kit
Note 2 : 557.180.203 Loop Powered MINERVA 80 panels come complete with a special Loop
Powered ALXM (loop card) . An additional loop power ALXM card
(MINERVA-557.180.203) is required for each additional 2 loops.
557.180.014 ALXM (2 loop) expansion card for standard MINERVA 80
557.180.424 ALXM (2 loop) expansion card for T890
Note 3 : 557.180.092 MINERVA Loop powered insertion module converts MINERVA 8 and 16E
to Loop Powered panels.
Note 4: 557.180.454 T890/891 Bulkhead mounting kit
557.180.405 T690M Marine Power Unit
Page 5
tyco Fire & Tyco Electronic
Security Product Group
MINERVA 8-16E-T891 - Functional Schematic
Page 6
tyco Fire & Tyco Electronic
Security Product Group
MINERVA Repeaters
The MINERVA fully functional repeaters are
available for all models of the MINERVA series
controllers. The repeaters are LPCB approved
and offer the same control and monitoring
facilities as the main panel. Each repeater
includes one MPIM Module and up to seven
repeaters can be attached to the remote bus of
the main panel.
The technical specification for the repeater is the
same as the main panel shown on the previous
page, product codes are also shown there.
Remote Mimics
MINERVA addressable system. It is supplied as a Mimic is the local control facility which is not
single PCB, which may be mounted in an featured in a Mimic. Both Repeater and Mimic
expansion box or on the rear of a free-standing include audible and visible warning facilities.
panel, as required. It may be used to drive up to Technical Specification
80 zonal LED indicators, arranged in any
Dimensions: 235H x 190W mm
configuration, together with two FIRE LEDs, one
FAULT LED and one ISOLATE LED. These Operating Temp: -10°C to +55°C
indicators operate in the same manner as the Storage Temp: -20°C to +65°C
corresponding indicators on the panel. Relative Humidity: Up to 95% RH Non
A remote Mimic can be connected to the MPIM’s Condensing
configured as remote Mimic drivers via the remote Product Code
bus. Up to 16 MPIMs may be connected on to the
The 80-Way Mimic allows custom-made display 557.180.005
remote bus, each with a unique address [set on-
and presentation panels to be incorporated in the board]. The difference between a Repeater and a MINERVA 80 way mimic driver module
Page 8
tyco Fire & Tyco Electronic
Security Product Group
Desktop Printer
performance with paper handling flexibility and Weight: 4.3kg
quiet operation. Operating Temperature: 0°C to 40°C
Features Storage Temperature: -15°C to 40°C
• 240 cps draft/ 80 cps LQ. Relative Humidity: 10% to 90% RH
• Quiet operation [non-condensing]
• Lightweight and compact design
Operating Voltage: 180V to 264Va.c.
• 9 LQ fonts
• 2 paper feed paths EMC: BS EN 50081-1 and BS EN 50082-1
• Convertible push/pull tractor Product Codes
• Paper guide 557.180.214
• Auto loading
MINERVA printer LQ-300
• Paper park
• Cable feed recess 557.180.220
• Epson LQ standard terminal emulation LQ80 ribbon black (spare) for use with desktop
available printer.
The printer is designed as a low cost business • Parallel and serial interface 557.180.062
printer ideally suited for mounting adjacent to the Technical Specification MINERVA MPIM to printer lead (D type 25 way
fire control panel.The LQ-300 combines high Dimensions: 141H x 366W x 275D mm male)
Pager Interface
be used. The pager system requires a +12V d.c. Technical Specification
connection (from the MINERVA) and a serial port Dimensions: 328H x 190W x 75D mm
connection. If the transmitter needs to be located
System operating voltage: 12 to 13.8 Vd.c.
further than 2 m from the MINERVA, then a non-
standard serial printer cable may be used, up to a Effective radiated power: 500mW
maximum distance of 14m. Frequency range: 50-470 MHz
CAUTION: Before any installation is carried out, Channel spacing: 25KHz
an on site radio paging license must be obtained TX baud rate: 512 or 1200
by the customer. Care should be taken when
Type approval ETS 300 224, MPT1383 Cert No
designing pager systems. Normal practice
13249, EC type approved to ETS 300 682
indicates that a site survey should be done.
Approval No. 13331
Contact Product Management for additional advise
on site surveys. Product Codes
The Type A alarm pager can display alarm/fault 577.002.001
messages. The Type A maintenance pager Pager Transmitter
displays all messages sent by MINERVA. 577.002.002
The pagers:- Type A alarm pager
• Display messages sent out by the MINERVA 577.002.003
as displayed on the panel on the 4x20 LCD Type A maintenance pager
• Internal log of up to 40 events
• Audible and/or vibrate warning of event 577.002.006
• Allows the event log to be displayed. Pager aerial standard up to 500 metres
The transmitter:- 577.002.007
• Connects using a 9way D type MINERVA Pager aerial 60 db gain up to 1km
The MINERVA pager system is designed to
interface lead
provide a facility to signal all text messages or 577.002.008
• Can be setup for transmission to Type A
alarm/fault messages from a local transmitter to Optional feeder cable
• Using standard aerial, provides a 500 metre
the pagers.
sphere of transmission in open air
The transmitter connects to the serial printer port
of an MPIM, if a local printer is connected to the Manual - Vol08A-05-D1 “Ancillaries Manual”
controllers MPIM serial port, a second MPIM must
557.180.021 557.180.034
557.180.022
MINERVA plain cover assembly for use with MINERVA expansion housing surface
MINERVA terminal chamber PCB assembly
general purpose housings - see below
MINERVA Spares
The following additional items are available as 557.180.426 557.180.208
standard spares. Other components can be T890/891 marine applications unit MINERVA spare keys (used on MINERVA
supplied as specials. controllers mid '94 Onwards)
557.180.054
Product Codes 557.180.721
MINERVA 16 mounting plate kit
555.180.002 MINERVA 16E cover assembly dutch (spare)
557.180.200
MINERVA 16E front cover assembly 557.180.722
MINERVA main processor PCB no software fitted
557.180.408 (Available on BSO) MINERVA 80 cover assembly dutch (spare)
557.180.204
T890 Front cover assembly
Motherboard loop powered for use with MINERVA
555.180.003 80 (spare) Datasheet - Product Code PB56 “Minerva 8, 16,
MINERVA 80 front cover assembly 557.180.209 16E, 80 Panels”
557.180.407 (Available on BSO) Keyswitch assembly for use with MINERVA Manual - Vol015A-02-D1 “Minerva Range of
T891 Front cover assembly controllers (spare) Analogue Addressable Fire Controllers”
557.180.010
MINERVA 80 motherboard PCB
Page 10
tyco Fire & Tyco Electronic
Security Product Group
MINERVA Addressable Modules
An extensive range of ancillary modules has been dampers to be controlled, provide an interface to • Allows loop powering of sounders and/or beam
specifically designed for use with the MINERVA 8, shut down HVAC equipment. Other applications detector units
16E and 80 range of Fire Control panels. The include an interface between shopping centre • Monitoring of external equipment, e.g. smoke
M520 range of ancillary modules provide the tenants' premises and the landlords' central dampers
MINERVA Panel with a wide degree of systems control system. • Reduced installation cost
application flexibility. This allows the field With the high systems integrity offered on the • Removes the need for separate plant control
addressable loop from the control panel to both MINERVA Panel the command modules can also circuits
receive inputs to the system and control outputs be used to control a public address based building
from it. evacuation system. Datasheet - Product Code PSF86 “520 Series
This broad range of modules allows the scope of Ancillary Equipment” (unless otherwise indicated).
Features
the fire detection system to be significantly Manual - Vol08A-02-D* “Ancillaries Manual”
• Communications and control interface to
extended beyond a simple fire detector - alarm * Design section indicated next to product code.
MINERVA Fire Panels
sounder based alarm system. The command
• High Systems Integrity
modules enable fire doors to be closed, fire
• Allows remote sounder circuits
Page 11
tyco Fire & Tyco Electronic
Security Product Group
DM520 - Conventional Detector Module
The DM520 is used to interface a single zone of Technical Specification
conventional detectors onto the MINERVA Powered: 24V d.c.
analogue addressable loop. This provides a cost
Temperature Range: -10°C to 70°C
effective and easy method of extending existing
conventional systems or a future upgrade path for Operating Humidity: up to 95% RH non-
new conventional systems. The DM520 is also condensing
fitted with a red LED to indicate locally when the Dimensions: 60H x 84W x 14D mm
associated conventional zone has entered an Product Codes (Vol08A-02-D2)
alarm condition. The DM520 requires a separate
517.035.012
24V d.c. supply to operate. The module is
addressable and will therefore take one address DM520 conventional detector module
on the loop. 517.035.018
DM520/M520 detector module and cover
assembled
Page 12
tyco Fire & Tyco Electronic
Security Product Group
LPBD521 - Loop Powered Beam Detectors
power the analyser unit, the beam receiver unit Product Code
and the transmitter unit. Alternatively, two 557.180.217
separate LPBD521's can be used with one to
LPBD521 loop powered beam detector interface
power the analyser unit and receiver units and the
module for use with FireRay 2000
second to drive the transmitter separately, either
from the same loop or a different loop. Up to 8
LPBD521's can be used per loop. Datasheet - Product Code PSF85 “Fireray 2000
The module is addressable and will therefore take Optical Beam Smoke Detector”
one address on the loop. Manual - Vol08A-02-D22 “520 Series Ancillary
Technical Specification Equipment”
Powered Loop
Temperature Range -10°C to 70°C
The LPBD521 module is used to drive the FireRay Operating Humidity up to 95% RH non-
2000 beam detector units directly from the condensing
MINERVA loop. A single LPBD521 can be used to
Dimensions: 60H x 84W x 14D mm
Page 13
tyco Fire & Tyco Electronic
Security Product Group
SU521 - Shop Interface Module
The SU251 is an addressable, multi input/output All outputs are change-over contacts rated at 24V
device that is used to interface other fire or 1A. The SU521 takes its operating power from
security systems into the MINERVA control panel. the MINERVA loop.
Inputs can be used for taking signals from other Technical Specification
systems (e.g. taking individual shop security
Powered: Loop (0.54mA)
systems into the central shopping centre system)
whilst the outputs can be used to send control Temperature Range: -10°C to 70°C
signals from the MINERVA back to the individual Operating Humidity: up to 95% RH non-
tenant's system. The SU521 can be configured in condensing
one of three formats: Dimensions: 72H x 245W x 17D mm
SU521/2 2 inputs and 2 outputs (Takes 4 Product Codes (Vol08A-02-D15)
addresses on the loop; max per loop is 24)
568.001.013
SU521/4 4 inputs and 4 outputs (Takes 8
SU521 shop unit interface
addresses on the loop; max per loop is 12)
547.004.001
SU521/6 6 inputs and 6 outputs (Takes 12
addresses on the loop; max per loop is 8) Din rail mounting kit
Page 14
tyco Fire & Tyco Electronic
Security Product Group
Addressable Fire Systems - UL/FM Approved
Analogue Addressable TFX-400 Series
AUTOCALL TFX-400 meets the needs of any Technical Specification
small-to-mid size building or building complex; Note: AUTOCALL TFX-400 is intended for use
networking capability allows the TFX-400 to be within a building interior, free from exposure to
used in larger buildings or building complexes. moisture, condensation and excessive dust.
Features Operating Temp.: 0 to +49oC
. 198 Analogue addressable points Humidity: 85% Non-Condensing
. Fully upgradable Loop Styles: NFPA 72 Style 4 & 6. Line
. Ideal for retrofit applications isolators optional for short
. System status information at a glance circuit isolation
. One panel size with many features of larger Max. Add Per Loop: 99
TFX panels Max Loops per Sys: 2
. Compact cabinet fits between wall studs Operating Voltage: 26Vd.c., 300mA
. Cabinet space for up to 17 Amp hours of Supervisory Current: 20mA per loop (plus load)
battery 24mA per loop (plus load)
. Semiflush or surface mount flexibility Resistance: Max. 75Ohms
. Low cost Capacitance: Max. 0.5 microfarad (mutual)
Features - Options Inductance: Max. 1.5 millihenry (total)
. Remote OCP and virtual front panel Product Codes
. Networking capability 557.180.625
. Graphical user interface TFX400 Two loop UL/FM approved fire control
TFX400 Listings & Approvals panel. Supplied in grey with Thorn Security
. UL Listed, File S2561 branding.
The AUTOCALL TFX-400 is a self contained, - Local 976422
small addressable panel in a single cabinet. The - Local with Releasing Device Service TXF400 Two loop UL/FM approved fire control
AUTOCALL TFX-400 includes 2 analogue, - Auxiliary panel. Supplied in red with Grinnell branding.
addressable signalling line circuits that provide 99 - Remote Station (Protected Premises Unit)
points each. Proprietary (Protected Premises Unit)
The AUTOCALL TFX-400 uses proven technology, - Central Station (Protected Premises Unit)
used in the TFX-500M and TFX-800M fire alarm - Fire Alarm Control Unit
and detection systems. The AUTOCALL TFX-400 - Proprietary Receiving Unit
control is designed to be used with conventional or - Central Station Receiving Unit
analogue, addressable fire detection devices, in . CSFM No. 7165-1493:147
any combination. As a stand alone panel, the 7170-1493:167
Page 16
tyco Fire & Tyco Electronic
Security Product Group
Power Supplies (See Note)
910683
Page 17
tyco Fire & Tyco Electronic
Security Product Group
Multi Purpose Interface Module
Features Operating Voltage: +5Vd.c., +12Vd.c., -12Vd.c.
. Remote (RS-485) and local bus communication Operating Current:
module Normal: 19mA
. Interface to annunciators, printers and Alarm: 24mA
Input/Output points Maximum distance from MP-500 (Main Processor
. Interface to remote operator display and control Board):
panels Local Bus: 60cm
. Up to 80 input/output points per MPIM Remote Bus: 2500m
. Up to 16 MPIMs on the remote bus Communications Method:
. Up to 16 MPIMs on the AUTOCALL TFX-500 Local Bus: Synchronous 1
series local bus MBit/sec
. Up to 11 MPIMs on the AUTOCALL TFX-800 Remote Bus: RS485, 4800
The AUTOCALL Multi Purpose Interface Module series local bus baud
(MPIM) is the communication interface between . May be installed up to 4000 feet remotely from Expansion Bus: Mulitplexed
the AUTOCALL TFX control panel and certain panel Serial Port: RS232, 4800
remote system functions. MPIMs communicate Listings & Approvals Baud
with the main processor module through the . UL Listed; File No. S2561 Product Code
system’s local or remote (RS485) bus. Each MPIM . CSFM No. 7165-1493:147 976015
module is assigned a unique bus address by 7170-1493:167 TFX-MPIM Multi purpose interface module for
means of programming jumpers. . MEA No. 415-92-E Vol. VI driving additional LED indicators, status control
The MPIM mounts in the AUTOCALL TFX panel . FM ID No. OX2A8.AY modules, I/O expansion and printers. Refer to
enclosure, a local or remote AUTOCALL TFX Technical Specification manual for limitations
display panel enclosure, or a suitable listed Dimensions: 165H x 91W x 25D mm
enclosure. It connects to the local or remote bus of Operating Temp.: 0oC to +50oC
an AUTOCALL TFX system. Operating Humidity: 85% (Non Condensing)
Page 19
tyco Fire & Tyco Electronic
Security Product Group
AUTOCALL CAA-500LI Module
6 circuit, this causes a shorted section between Listings & Approvals
two CAA-500LI modules to be isolated from the . UL File Number S374
rest of the loop. The AUTOCALL TFX panel . CSFM No. 7300-1493:152
indicates which devices in the loop have been . MEA No. 415-92-E Vol. VI
isolated, to assist in locating and correcting the . FM ID No. OX2A8.AY
short circuit condition. Once the short circuit has Technical Specification
been cleared, the CAA-500LI automatically resets, Dimensions: 112.5H x 112.5W x 25D mm
and communication with the isolated devices is Operating Temp.: 0oC to 50oC
restored. Operating Humidity: 85% (Non Condensing)
Features Operating Voltage: 28Vd.c. maximum
. Isolates short circuits on signalling circuit to Signalling Circuit Current:
The AUTOCALL CAA-500LI module is used only
prevent failure of entire circuit Standby Current: 0.7mA
with the AUTOCALL TFX fire control panels to
. Automatically resets on correction of short Alarm Current: 0.7mA
detect and isolate short circuits. This module
circuit Cover Material: Polycarbonate ABS Alloy
should be installed between groups of addressable
. Status LED indicates short circuit detection Product Code
devices to prevent failure of the entire signalling
. No external power required 976026
circuit loop in the event of a short circuit. Upon
. High EMF/RFI noise immunity TFX CAA-500LI Line isolator module complete
detection of a short circuit, this module opens up
. May be configured to meet NFPA style 7 with 2 gang mounting plate
the positive leg of the signalling circuit. On a Style
requirements
Page 21
tyco Fire & Tyco Electronic
Security Product Group
Pullstations & Ancillaries
Hazardous Locations Technical Specification
The RMS series explosion proof, weather proof Dimensions: 118H x 83W x 37D mm
pull stations are constructed of high strength metal (RMS-1T)
die cast alloy. 118H x 81W x 43D mm
The UL rating of Class I Group B (Hydrogen) C & (RMS-1T WP-LP)
D, Class II Groups E, F, G, Class III and outdoor Weight: 560g (RMS-1T)
rating of type 4X, allows these stations to offer 909g (RMS-1T WP-LP)
unmatched placement flexibility. The terminal Contact: Single pole, single throw
block connections, D.P.D.T contacts @ 10 amps (double pole, single throw
meet most electrical requirements indoors and out. optional)
Having a ‘conventional’ pull station design the Contact Rating: 10 Amps @ 125/250Va.c.
RMS series stations offer easy identification. Wire AWG: 12 to 22 AWG
Features Wiring: Terminal block connections
The RMS series manual pull stations are of high . Die cast metal construction (6-32 w/sem plate)
quality non-toxic die-cast construction. . Low profile functional design Switch: 10 Amp @ 120Va.c.
Low profile and smooth edges offer an attractive . Dual action option Key Switch: (pre-signal) 0.5 Amp 30Vd.c.
yet functional design. All components are pre- . Institutional (Key operated) option Product Codes
painted or have plated surfaces to inhibit . Explosion proof option 960673
corrosion. . Break glass option TFX RMS-1T Single action non addressable pull
The RMS series manual pullstations have a 10 . Weatherproof option station
amp snap action switch. They can be used with or . Hex screw or key lock reset options 960678
without a break glass rod for positive indication . UL Listed TFX RMS-1T WP-LP Dual action weatherproof
that the unit has been operated. pullstation
Page 22
tyco Fire & Tyco Electronic
Security Product Group
Releasing Equipment
Technical Specification
Dimensions:
GARA-1: 128H x 175W x 51.5D mm
GAR-1 118.75H x 84W x 51.5D mm
Operating Temp.: 0 to +50oC
Operating Humidity: 85% Non-Condensing
Terminal Block Wiring:No. 12AWG shielded (Max.)
Current Requirements:
GARA-1: 0.0mA Supervisory;13mA
Alarm
GAR-1: 0.0mA Supervisory; 0mA
GARA-1 GAR-1 Alarm
Product Codes
The AUTOCALL GARA-1 and GAR-1 fire Features 976376
suppression agent releasing stations are suited for . Releasing station constructed of die-cast metal TFX GARA-1 Addressable gas agent releasing
use wherever releasing or pre-action deluge . Low profile functional design and abort module
applications are required. . Dual action 976381
The GARA-1 and GAR-1 fire suppression agent GARA-1 Additional Features TFX GAR-1 Addressable gas agent releasing
releasing stations use normally open contacts. The . Abort switch station
stations operate and reset easily, and may be . System activated indication 976413
semi-flush or surface mounted. . System normal indication TFX505SDA/RM Panel mounting addressable gas
The GARA-1 includes an abort switch as well as a Listings & Approvals release solenoid control kit
“system normal” LED. . UL Category UOXX, File No. S374. UL Listed 976414
Both fire suppression agent releasing stations are for fire alarm and releasing service TFX 506SDA/RM Addressable gas release
compatible with the AUTOCALL TFX series fire . MEA No. 415-92-E, Vol. IX solenoid control kit for installation remote from the
alarm systems. The stations are also compatible . CSFM No. 7165-1493:147 panel
for use with all UL listed solenoids used in 7300-1493:152
sprinkler systems, when used in conjunction with 7170-1493:167
the 505SDA/RM (976414) or 506SDA/RM
(976413) agent releasing kits and the RPS-424
power supply/ battery charger (910683).
Page 23
tyco Fire & Tyco Electronic
Security Product Group
Conventional Fire Alarm Panels - BS5839 and EN54
MINERVA 1-4 Conventional Fire Controllers
performance and minimum lifetime costs. Quiescent Current: 90mA plus 10mA per zone
Particular attention has been paid to the Alarm Current: 150mA plus 100mA per
appearance of this unit, recognising that in many zone
installations the control panel may be on display in
Operating Temp.: -10ºC to +55ºC
a reception area.
Relative Humidity: up to 95% non-condensing
The controller has been designed to prEN54 pt 2
& 4 and approved to BS 5839 part 4. IP Rating: IP33
The design and manufacturing facilities of ADT Material: Polycarbonate/ABS Alloy
Fire & Security are ISO9001/BS 5750 accredited. Branding: Supplied with multiple Tyco
Features branding
. Available in 1, 2 or 4 zones Product Code Language Zones
. LPCB approved to BS 5839 Pt 4 -1988 508.018.001 ADT(UK) 1
. Integral charger and batteries 508.018.002 ADT(UK) 2
. Simple LED display and push-button operator
508.018.004 ADT(UK) 4
controls
. One man walk test facility enables easy 508.018.012 Dutch 2
commissioning and maintenance with 508.018.014 Dutch 4
minimum disruption 508.018.021 English 1
. Zone disable function for each zone via front 508.018.022 English 2
panel
. May be used with BASEEFA Approved 508.018.024 English 4
Intrinsically Safe System 601 508.018.031 Arabic 1
. Two sounder circuits with sounder delay 508.018.032 Arabic 2
options 508.018.034 Arabic 4
. Non-latching alarm input
. Remote fault input, class change input
. Earth fault monitoring MINERVA 1-4 Ancillaries
. Cross-zoning facility available 509.018.001
. Optional alert/evacuate facility enables
Conventional MINERVA Battery Clamp For Use
callpoints to generate an evacuate alarm and
With All 1-4 Zone Controllers
The MINERVA 1,2 and 4 zone conventional detectors an alert warning
509.018.002
controller has been engineered to bring a high
quality, low cost, LPCB Approved unit to the Technical Specification Conventional MINERVA Semi-Recessed Mounting
market-place without compromising the features Bezel Kit For Use With All 1-4 Zone Controllers
Dimensions: 290H x 340W x 90D mm
offered to the client. 509.018.010
Weight: 3.7Kg (without batteries)
Ideally suited to offices, shop units, small guest Gland Cover To Hide Cable Entry To 1-4 Zone
Power Supply: 220/240Va.c. +/- 10%
houses and manufacturing/warehouse units, it Controller
may also be used as a local controller as part of 50/60Hz
509.018.006
an integrated system in areas such as shopping Maximum Battery: 7Ah
Active EOL Device
malls or computer suites. Sounder Circuits: 2 x 500mA @ 24Vd.c.
517.050.007
Advanced design and manufacturing techniques, Alarm/Fault/Zone relays: 1A @ 24Vd.c.
M600D Continuity diode base
including a powerful custom ASIC microchip and Zone Voltage: 21.3V nominal
surface-mount printed circuit boards combine to Minerva 1-4 Spares
Internal Charger: 3.3A @ 32.5V
offer a simple and reliable controller with optimum 509.018.101
PSU for 1 zone (spare)
MINERVA Conventional Schematic 509.018.102
PSU for 2 zone (spare)
509.018.104
Non PSU for 4 zone (spare)
Remote latching Class
alarm change 509.018.105
fault
Control PCB 1 Zone (spare)
509.018.106
2 monitored
sounder circuits Control PCB 2 Zone (spare)
509.018.103
Alarm Control PCB 4 Zone (spare)
output MINERVA
Fault CONVENTIONAL Datasheet - Product Code PSF72 “Minerva 1, 2 &
output 4 Zone Panel”
CONTROL
Field supply Manual - Vol04A-01-D1 “Minerva 1-4 Zone
Zonal UNIT
Conventional Fire Controller Manual”
output(s)
1, 2 or 4
detector
M300/600 Series Detector circuits
Page 24
tyco Fire & Tyco Electronic
Security Product Group
XL100 Fire Detection Control Panels
General Wiring Diagram
Page 25
tyco Fire & Tyco Electronic
Security Product Group
System 1700
A uniquely flexible series of basic fire controllers. Conventional style monitored detector zones, • Selective sounder operation
Covering 4 or more zones of fire detection and each consisting of up to 20 standard smoke heat • All circuits fault monitored
suitable for cost effective protection in a wide detectors or callpoints. • Remote signalling output
range of building types. Detection, display, alarm, Remote display or control are driven by a • Designed for fire alarm systems specified to
and extinguishing control, can be tailored to meet multiplex transmitter/receiver system on a single BS5839: Part 1:1988
any need. pair cable. Each transmitter can feed up to 4 • Proven exceptionally reliable world-wide
Technical Information receivers, at a distance of up to 1Km. Display
legends are replaceable. Standard legend is Datasheet - Product Code PSF41 “System 1700
System 1700 consists of 14 standard modules,
English or on the reverse Arabic/English, but Conventional Fire Controller”
selectively assembled in one of 5 housings which
can be flush mounted using the appropriate kit - to blanks are available to suit other customer Manual - FD-1.1.31.02 “Fire Detection Manual”
meet any specific customer requirement within the requirements.
designed capacity. These units can be configured Features
to provide fire detection with local display, remote • Expandable in four zone increments
display, extinguishing control or any combination • Customised by module selection - uniquely
of these functions with integral power units and flexible
secondary batteries or from separate 24Vd.c. • Integral battery and charger
power supplies. Alarm sounder outputs can be • Simple controls
commoned or pre-programmed for specific • Local and remote displays
building sectors. • Easy installation and extension
Page 26
tyco Fire & Tyco Electronic
Security Product Group
Four or Eight Zone Module with Display
Provides the power to each detection zone which
respond to four conditions, open-circuit fault,
quiescent, alarm or short-circuit fault. Individual
indication is given for either Alarm or Fault. Each
zone has a corresponding output which is
energised in an alarm condition and is suitable for
driving zonal relays and/or auxiliary modules i.e.
multiplexed repeater.
508.014.023 508.014.024
1700 4 Zone PCB & Display 1700 8 Zone PCB & Display
Relay Module
Mounted internally and has 4 heavy duty relays
each with a single changeover contact (rated 5A
@ 30Vd.c.). The relays are normally energised
from the individual zone outputs of the zone
module.
Product Code
508.014.028
1700 Relay PCB
Page 27
tyco Fire & Tyco Electronic
Security Product Group
Multiplex Transmitter Module
Transmits up to 16 independent signals plus
common alarm or fault to up to 4 multiplex
receiver modules at remote locations over a pair
of signal wires (max. length 1 Km).
Product Code
508.014.029
1700 Multiplex TX PCB
508.014.043.A 508.014.025
1700 Extinguishing Module Mounted In A Single 1700 Extinguishing Control PCB and Display
Aperture Housing ADT Branded (shown)
508.014.043.T
1700 Extinguishing Module Mounted In A Single
Aperture Housing Thorn Security Branded
Page 28
tyco Fire & Tyco Electronic
Security Product Group
Coincidence Module
Designed to activate one or both relays in
response to an alarm condition from up to eight
zonal outputs. This module is primarily used in
conjunction with the extinguishing module, but
may also be used for other applications.
Product Code
508.014.048
1700 Coincidence Module PCB
Housings
Technical Specification
Dimensions (mm) Weight Display
ADT Thorn Bezel Kit Housing Height Width Depth (Kg) Capacity Module Space
508.014.011.A 508.014.011.T 508.014.012 2 Aperture 354 336 133 5 2H 2
508.014.013.A 508.014.013.T 508.014.014 3 Aperture 354 420 193 7 1V + 2H 4
508.014.015.A 508.014.015.T 508.014.016 5 Aperture 354 637 193 9.5 1V + 4H 6
508.014.039.A 508.014.039.T 508.014.040 8 Aperture 760 531 233 14.5 8H 10
508.014.041.A 508.014.041.T 508.014.042 12 Aperture 1050 700 235 30 12H 18
H = Horizontal V= Vertical
As standard the System 1700 enclosures are Housing Accessories 1700 Battery Clamp Kits
available with Thorn or ADT Branding. A bezel kit 508.014.019 508.014.052
is available for flush mounting the panels
1700 Aperture Blanking Plate 1700 Battery Clamp Kit For 17Ah Batteries
Product Codes
508.014.034 508.014.053
508.014.047
1700 Custom Legend Strips Zones 33-64 1700 Battery Clamp Kit For 10Ah Batteries
1700 Installation Kit For 3 Aperture Housing English/Arabic 508.014.054
508.014.038 508.014.035 1700 Battery Clamp Kit For 7Ah Batteries
1700 Installation Kit For 5 Aperture Housing 1700 Custom Legend Strips, Blank System See Also Extinguishing Options
508.014.039.A 508.014.041.A
1700 8 Aperture 1700 12 Aperture
Page 29
tyco Fire & Tyco Electronic
Security Product Group
NT100 Conventional Controllers
Standard Fire Control PanelStandard Fire Repeater Panel
Country NT108 NT116 NT116R
U.K. 508.022.008 508.022.016 508.022.038
Spain 508.022.007 508.022.019 508.022.039
Belgium 508.022.009 508.022.017 508.022.044
Holland 508.022.010 508.022.018 508.022.045
Fire Panels with Integral Fireman’s Interface
Country NTF08 NTF16
Finland 508.022.011 508.022.029
Denmark 508.022.014 508.022.032
Norway 508.022.012 508.022.030
Sweden 508.022.013 508.022.031
Holland 508.022.042 508.022.043
The range of NT100 panels are state-of-the-art Product Codes Anciliaries
intelligent fire panels, which provide many of the
The following product codes include all the 509.022.014
features normally only found on more expensive
optional extras which can be included as part of NT 3 Metre -Cable Assembly For Connection Of
analogue addressable panels. The range of
your customer's requirements. Additional spare NTX-01 To NTX-02/3/4 Typically Used For
control panels are LPCB approved to EN54Pt. 2
parts are also included. Connection To Remote NTX-02 Relay Unit
and 4 and include many local approval authorities
around the world. The panels are supplied in 8 509.022.001 509.022.XXX (See Note 1)
and 16 zone versions. Each detection zone can NT100 Series Spare Commissioning Kit NT/NTR/NTF CPU Board V1.7 Spare
support up to 32 conventional detectors. The user Included With All Panels 509.022.031
interface is provided through a combination of
509.022.008 NTF Fireman’s Interface PCB Spare
LEDs and a 2 x 40 character LCD display. The
LCD display provides a full customer definable PRN-02 Spare Printer Paper For PRN-01 509.022.032
text display of the alarm or fault condition whilst (Supplied In Packs Of 5 Rolls)
NTR Release User Interface PCB Spare
also displaying zones in alarm, fault or isolate 509.022.009
509.022.033
status. The display also indicates the outputs that PRN-03 Spare Printer Ribbon For PRN-01
have been activated. Each control panel can have NT/NTR/NTF Display PCB Spare
509.022.011
up to a maximum of 3 repeaters. 509.022.034
NT100 Spare PSU For NT,NTR & NTF Variants
Features NT PSU Plug In Fuse 2 (Pack Of 10)
509.022.012
• LPCB & ANPI (BOSEC) approved to EN54
Parts 2 and 4 Bulkhead Mounting Kit
NOTE 1: All NT Panels now use one version of
• Customer friendly, multi language information 509.022.013 main CPU core software (V1.7). Product Code not
on LCD display NT Flush Mount Bezel NT-I/O Expansion available at time of going to press.
• Comprehensive fault diagnostics
• 8 and 16 zone Panels General Wiring Diagram
• Can be used with a wide range of approved
detectors
• Detector removal monitoring
• 4 monitored Sounder outputs up to 4A
• 4 monitored Relay outputs
• 3 programmable auxiliary inputs
• 3 levels of alarm discriminations per zone
• One common fault relay
• Internal batteries (up to 12Ah)
• Programmable cause and effect
• Programmable user access levels
• Can interface to intrinsically safe System 601
• Manned/ unmanned mode
• Optional fireman's interface
• Optional printer
• Optional repeater units
• Optional I/O expansion board
• 16 digital outputs or 16 relay output options
Technical Specification
Dimensions 320H x 430W x150D mm
Weight 6.3kg
Power Supply 198 -264Va.c.
Quiescent Current 50mA @ 24Vd.c.
Alarm Current 1Amp @ 24Vd.c.
Operating Temp 0 to +40°C
Operating Humidity 0-90% RH non-condensing
Page 30
tyco Fire & Tyco Electronic
Security Product Group
509.022.004 509.022.005
509.022.007
NTX-02 16 Way Relay Output Board NTX-03 16 Way Digital Output Driver Board -
PRN-01 Optional Integral Printer for use with NT &
(24Vd.c.@1A) Requires NTX-01 Expansion Board Requires NTX-01 Expansion Board
NTF Controller Variants
509.022.003 509.022.006
NTX-01 4 Way Expansion Board - Supplied Fitted NTX-04 16 Way Digital Input Board for use on
to the NTF And NTR Controllers. Also Supports Special NT Controller Variants only
NTX-02,03,04 Expansion Boards
Page 31
tyco Fire & Tyco Electronic
Security Product Group
NTR - Typical Wiring Schematic for Single Area Panels
Extinguishant Initial/Reserve Schematic with Pilot Container Solenoid Extinguishant Initial/Reserve Schematic with Extinguishant Solenoid
Page 32
tyco Fire & Tyco Electronic
Security Product Group
T530 Extinguishing Release & Detection Panel
and monitoring of all output relays, lamps and Alarm Current: 420mA plus 70mA per zone
externally connected devices. Detectors can be in alarm and 150mA when
installed to give either a gated (delayed) or extinguishing control active
immediate response. Coincident operation in the Dimensions: 270H x 400W x 190D mm
automatic mode will initiate the gas release cycle;
Weight: 11.5kg
distinctive sounders give a pre-discharge warning
and any air-handling plant can be automatically Operating Temp: -10 to +55oC (Storage -20
switched off. After a time delay the gas release to +65oC)
mechanism is operated. Humidity: up to 95% RH non-
Features condensing
• Dual path circuitry to prevent a single fault dis- EMC/RFI: CE marked
charging gas Product Codes
• Microprocessor controlled for system integrity 508.013.036.A
The T530 is designed to control an automatic fire • Bright, clear display provides vital status infor-
T530 4 Zone Fire Detection and Extinguishing
detection system and in conjunction with its mation
Control Panel - ADT branded
associated range of ancillary equipment, will • Simple user controls reduce operator error
provide complete control of a gaseous • Detector gating and two-stage sounder options 508.013.036.T
extinguishing system. The micro-processor based • Extinguishing 'hold' and 'abort' facilities T530 4 Zone Fire Detection and Extinguishing
T530 provides four fire detection zones, two of • Zone test and sounder test facilities Control Panel - Thorn branded
which are dedicated to the extinguishing area • Integral power supply 599.001.020
(coincident operation) and two for the protection of • Can be installed to meet the requirements Spare lamp - 36V 30mA bi-pin
the peripheral areas. The T530 monitors the BS5839 Part 1 & BS6266
connections to the external sounders, pressure • Designed to comply with BS7273 527.001.013
switches, actuators, etc. and initiates the • One man walk test Spare Frangible Washers (Pack of 25)
appropriate actions in response to signals from • 4 zone capacity 509.013.145
either the detection zones or manual release • Zone Isolate T530 Programmed EPROM Version 4.0
units. The T530 also incorporates facilities for Technical Specification
'hold' or 'abort' of the gas discharge (prior to Datasheet - Product Code PSF30 “T530 Fire
Mains Supply: 240V a.c. 50Hz Detection & Extinguishing Systems Control Unit”
release) and remote status indication.
Charger Output: 24V d.c. 2.5A continuous Manual - FSSD-1.1.30.1 “Fire Detection Manual”
The microprocessor enables a high level of
Quiescent Current: 24V d.c. 220mA
integrity to be achieved, including self-checking
Page 33
tyco Fire & Tyco Electronic
Security Product Group
T525 Extinguishing Mode Select Switch
up to 8 units can be connected to an NTR, T520 Humidity: up to 95% RH non-
or T530 system alternatively two T525 units can condensing
be configured in a "tunnel" mode for entry and exit IP rating: IP54
routes on a watchman's tour.
EMC/RFI: CE marked
The T525 incorporates dual long life / high
Product Codes
brightness lamps to indicate system status as
follows: 526.001.021.A
Gas Release: Red T525 Extinguishing System Auto/Manual Mode
Select - Unbranded
Automatic Mode: Yellow
526.001.021.T
Manual Mode: Green
T525 Extinguishing System Auto/Manual Mode
Mode Select operated: Green
Select - Thorn branded
Technical Specification
599.001.012
Input power supply: 24Vd.c. nominal
Spare lamp 28V 60mA for use on T525
Current consumption:Standby - 212mA max.
The T525 is a remote mode select and indication Alarm - 318mA max.
Datasheet - Product Code PSF30 “T530 Fire
unit for use with NTR, T530, T520 and System Lamps rating: 28Vd.c. @ 60mA rated for
Detection & Extinguishing Systems Control Unit”
1700 extinguishing systems. Normally sited at the 8000 hours
entrance to the hazardous area, this allows Manual - FSSD-4.1.8.1 “Fire Detection Manual”
Dimensions: 138 H x 178 W x 52 D mm
personnel to enter or leave without risk of being Weight: 1 kg
caught in an automatic gas discharge. Typically
Operating Temp: -20 to +55oC
Page 34
tyco Fire & Tyco Electronic
Security Product Group
Weatherproof Extinguishing Indicator Units
540.007.001
E1 Single Red lamp unit
Heavy Duty IP67 Cast Aluminium Surface Mount
Lamp Unit. Single 24V d.c. red lamp labelled 540.007.006
'Extinguishing System Operated' 540.007.002
I3 Red/Amber/Green lamp unit
E3 Red/Amber/Green lamp unit
Technical Specification Sealed IP67 ABS Surface Mount Lamp Unit
Heavy Duty IP67 Cast Aluminium Surface Mount
Dimensions: Three 24V d.c. lamps:
Lamp Unit Three 24Vd.c. lamps:
H(mm) W(mm) D(mm) Red labelled 'Gas Released'
Red labelled 'Extinguishing System Operated'
E1 100 100 115 Amber labelled 'Auto'
Amber labelled ' Extinguishing System Automatic
E3 300 100 115 Control' Green labelled 'Manual'
I3 230 75 75 Green labelled 'Extinguishing System Manual 540.007.007
I4 230 75 75 Control' I4 lamp unit as I3 including auto/manual keyswitch
Pre-discharge sounders
Alarm sounders
Pressure Switch
Container
Remote Signalling Fault Input
Solenoid
Valve
Power FM200
AC Container
Supply
T526
T525 T527 /T529
Page 35
tyco Fire & Tyco Electronic
Security Product Group
Conventional Marine Panels (See also MINERVA Section)
T1000
• 4 monitored Relay outputs Product Codes
• 3 programmable auxiliary inputs 508.022.035
• 3 levels of alarm discriminations per zone
• One common fault relay T1008 8 zone marine NT conventional fire
• Programmable cause and effect Controller
• Can interface to intrinsically safe System 601 508.022.036
• Manned/ unmanned mode T1016 16 zone marine NT conventional fire
Technical Specification
Controller
Dimensions: 320H x 430W x 150D mm
508.022.037
Weight: 6.3kg
T1016R repeater for use with T1008 & T1016
Power Supply: 198 -264Va.c.
Quiescent Current: 50mA @ 24Vd.c.
Alarm Current: 1Amp @ 24Vd.c. Datasheet - Product Code PSF96 “T1000
The range of T1000 panels are state-of-the-art Operating Temp: 0 to +40°C Intelligent Control Panels”
intelligent fire panels, which provide many of the
Operating Humidity: 0-90% RH non-condensing
features normally only found on more expensive
analogue addressable panels. The panels are Optional Product Codes 509.022.012
supplied in 8 and 16 zone versions. Each The following product codes include all the Bulkhead Mounting Kit
detection zone can support up to 32 conventional optional extras which can be included as part of
detectors. The user interface is provided through 509.022.013
your customer's requirements. Additional spare
a combination of LEDs and a 2 x 40 character Flush Mount Bezel
parts are also included.
LCD display. The LCD display provides a full 509.022.014
509.022.001
customer definable text display of the alarm or NT 3 Metre -Cable Assembly For Connection Of
fault condition whilst also displaying zones in NT100 Series Spare Commissioning Kit Included
NTX-01 To NTX-02/3/4 Typically Used For
alarm, fault or isolate status. The display also With All Panels
Connection To Remote NTX-02 Relay Unit
indicates the outputs that have been activated. 509.022.003
509.022.015
Features NT100 4 Way Expansion Board - Support NTX-
T1000 Display PCB Spare
• Developed for Vessels with less than 300 02,03,04 Expansion Boards
509.022.016
Detectors 509.022.004
• Approved by all Major Marine Authorities T1000 CPU board V1.6 spare
NT100 16 Way Relay Output Board (24Vd.c.@1A)
• Customer friendly, multi language information Requires NTX-01 Expansion Board 509.022.024
on LCD display T1000R CPU board V1.6R spare
509.022.005
• Comprehensive fault diagnostics
NT100 16 Way Digital Output Driver Board - 509.022.034
• 8 and 16 zone Panels
• Can be used with a wide range of Minerva Requires NTX-01 Expansion Board NT PSU Plug In Fuse 2 (Pack Of 10)
Marine approved Detectors 509.022.010
• 4 monitored Sounder outputs up to 4A Spare PSU For T1000
Page 37
tyco Fire & Tyco Electronic
Security Product Group
T880 Thirty-Two Zone Conventional Marine Fire Controller
• One latching common alarm contact rated 3A Product Codes
@ 30Vd.c. resistive 508.013.012
• One latching common fault contact rated 3A @
T880 Control Unit Deep
30Vd.c.
Terminal Field E:- 508.013.013
• Zone terminals 9 to 32 T880 Control Unit shallow
• 4 relays rated 1A @ 30Vd.c. resistive. The 508.013.002
relays can be programmed to activate by
T280 Repeater Unit
zone(s) with an additional zonal mimic drive
PCB, 401.006.012 (Available from Thorn Marine)
Options:- Sounder pulsing module
• Optional lamp dim module used to provide a 400.007.003 (Available from Thorn Marine)
variable output to the controller lamp supply for T880 Handbook
dimming purposes. This is normally only
required if the system does not use a T680 401.011.008 (Available from Thorn Marine)
power unit. Bezel for deep housing
The T880 control unit forms the heart of a • Optional sounder pulsing module to permit 401.011.009 (Available from Thorn Marine)
sophisticated and flexible marine fire detection predefined sounder circuit pulsing Bezel for shallow housing
system. The T880 provides control of up to 32 configurations.
• Optional Earth leakage monitor 509.013.001
conventional zones of fire detection. For
Technical Specification Nicad battery for total power fail warning (included
exceptionally large vessels, up to three controllers
Operating temp.: -25°C to +70°C with new control panel)
may be linked together to give 96 zones of fire
detection. The T880 unit comprises, display and Storage temp.: -25°C to +70°C 509.013.002
electronics PCB assembly, terminal field A and T880 front cover
Humidity: 95% RH non-condensing
terminal field E in either a deep or shallow 509.013.059
housing. The deep housing permits the The control panel is normally mounted onto a
bulkhead using the H frame bracket. Bezels for Zone output/ mimic drive PCB
convenient installation of additional optional circuit
boards in the same housing. The control panel both deep and shallow housings are available. 509.013.062
normally receives its power from the T680 power The deep housing has two removable gland Zone output PCB c/w ribbon connector
changeover unit, or alternatively, the C2440, if plates (top and bottom) for cable access. The
509.013.048
ship's 24Vd.c. supply is not available. shallow housing has eight 20mm knock outs, both
top and bottom. Terminal Field A
Features
Housing is zinc plated 1.6mm thick mild steel. 509.013.061
• Approved by a variety of marine authorities
Finish is grey epoxy powder paint 9-094, to Terminal Field E
• Up to 32 fire detection zones
• Two alarm levels per detection zone (except BS2660. 509.013.108
I.S. zones) Front cover assembly moulded from a flame Lamp dim module
• 2 monitored bell circuits selectable as retardant polyester glass filled compound, finished 509.013.055
continuous or intermittent in blue-grey 9-098, to BS2660.
T880 Spares kit
• Secondary alarm output delay (up to 3 mins)
T880 T880 T280 509.013.028
• Multiplexed data I/O
• Interfaces directly with up to four T280 32 zone Deep Shallow Shallow T280 Spares kit
repeater unit or zonal mimic drive PCB’s Size (mm) 509.013.121
• Panel test and isolate mode Height 385 385 390 T880 variable legend kit
• Can interface to intrinsically safe System 601
Width 398 398 398
• Lamp dim feature
• Replaceable legend Depth 171 95 95 Datasheet - Product Code PSF16 “System 1600
Other input/output facilities:- Weight Kg Conventional Fire Controller”
Terminal Field A:- With H frame 15 10 13.5 Manual - UHM3 “Marine Fire Manual”
• Zone terminals 1-8 Without H frame 11.5 6.5 10.5
• Two monitored sounder circuits rated at IP rating 53 53 53
24Vd.c. 2.5A each.
Page 38
tyco Fire & Tyco Electronic
Security Product Group
Batteries, PSU and Door Release
Batteries
Product Codes 3071 560.001.015
660.001.003 Battery sealed L-A replaces 660.001.009 and 30- Battery sealed L-A also replaces 3148, SLA17
Battery sealed L-A 105 and 30-109
560.001.013 660.002.010 660.001.004
Battery sealed L-A also replaces parts 3145 and Battery sealed L-A also replaces 3146, SLA04 Battery sealed L-A (Bolt terminal) also replaces
30-102 and 30-112 3014, SLA24 and 30-106
3085 3072 560.001.012
Battery sealed L-A also replaces 660.001.014 and Battery sealed L-A also replaces 660.001.005, Battery sealed L-A also replaces 3149, SLA38
SLA07 and 30-101 and 30-107
30-111
660.002.012 3150
3010
Battery sealed L-A also replaces 3147, SLA012 Battery sealed L-A also replaces SLA65 and 30-
Battery sealed L-A also replaces 660.001.007,
and 30-110 108
SLA21 and 30-103
Page 39
tyco Fire & Tyco Electronic
Security Product Group
Door Release Units
Technical Specification - Door Release Units
40-103 40-104
Dimensions: 85H x 85W x 46D mm
Armature Dims: Dia 72mm x 21mm deep
Voltage: 24Vd.c. 230Va.c.
Hold Force: 17Kg 20Kg
Current: 60mA 20mA
Product Codes Product Code Residual Magnetism: 5% 5%
40-103 40-105
Door release unit 24Vd.c. with keeper plate Floor mounting brackets for 40-103/104
40-104 Dimensions: 100H x 85W x 55D mm
Door release unit 240Va.c. with keeper plate
Cable Entry: 20mm
Door Release Power Supply
The Transformer Rectifier is a dual purpose, Technical Specification
smoothed power supply providing either an Input: 240Va.c.
energised or de-energised output upon activation. Output: 24Vd.c. 3A
The output may be activated by utilising a set of
volt free contacts from a fire or security panel, or Dimensions: 230H x 320W x 75D mm
by providing a 12/24Vd.c. trigger voltage from Product Code
other apparatus. The transformer rectifier units are 558.004.007
normally used to control the operation of other TRR-243 3A Door Release PSU
24Vd.c. equipment such as the magnetic door
retainers. The units are ideal for applications
where the supply is to be energised from a remote
source.
C Range Chargers
lead-acid battery and an attractive housing. Under • Automatic protection for short-circuit conditions
normal conditions, the charger provides all the is designed to prevent damage
system power and maintains the battery in the
charged condition. When the AC supply fails, the • Optional voltmeter and ammeter
stand-by battery takes over. Technical Specification
Features Operating Temp: -20oC to 55oC
Storage Temp.: -20oC to +70oC
• A range of chargers and housings to suit
different system configurations Relative Humidity: 95% RH non-condensing
Output Voltage: 27Vd.c.
• May be used with both conventional and
Product Codes
analogue addressable fire systems
558.004.006
The C2400 series power supply equipment • Large aluminium heatsink eliminates need for
C Range charger 24V 4 Amp
provides primary and secondary power for fire unsightly ventilation grills
558.004.003
alarm systems. The power supply consist of an • Temperature compensated output ensures C Range charger 12V 4Amp
AC supply operated charger, a stand-by sealed correct charging voltage at all times
Housing Type D
The housings are designed to match the current Product Codes
range of fire alarm controllers. The housings are 558.004.013
available in two sizes and can be supplied with an
Housing Type D complete with metres
ammeter and voltmeter if required. An ‘AC supply
on’ indicator is fitted. 558.004.014
Technical Specification Housing Type D
Type D: 420H x 436W x 210D mm
Holds charger and up to 2 x 38Ah sealed batteries
at 24V d.c.
Housing Type C
The housings are designed to match the current Product Codes
range of fire alarm controllers. The housings are 558.004.015
available in two sizes and can be supplied with an Housing Type C complete with metres
ammeter and voltmeter if required. An ‘AC supply
558.004.016
on’ indicator is fitted.
Housing Type C
Technical Specification
Type C: 290H x 416W x 160D mm
Holds charger and up to 2 x 12Ah sealed batteries
at 24V dc
Page 40
tyco Fire & Tyco Electronic
Security Product Group
Addressable 900 Series Detectors
Body Optical Ionisation HPO R of R Heat CO Features
LPCB MR901 MF901 MR901T MD901 MU901 • Unique early detection CO fire detector
NSTC MF901 MR901T • Intelligent Universal HPO Smoke Detector
• Low profile, discreet and unobtrusive
UL/FM* 912P 912I 912HP 912H
• Superior performance and reliability
ULC 912P/C 912I/C 912PH/C 912H/C • Unique ‘Smart Key’ feature
Marine MR901M MF901M MD901 • Designed for fast, easy installation
The M900 series are a range of low profile The M900 series includes the unique Carbon • Optional Locking Kit
addressable fire detectors. These unobtrusively Monoxide CO fire detector, which provides a • Integral and remote alarm LED
styled detectors have a number of unique design general purpose fire detector with unprecedented • Series of Product Approvals
features to improve their operation, installation early detection capability and excellent false alarm
and ease of servicing. immunity. The CO fire detectors are the first The M900 Low Profile detectors can be custom
Through innovative design the M900 Series choice for sleeping risks. made in several colours, please contact the
detectors have reduced the installation and Also included within the range is the intelligent Walthamstow office for details.
servicing time to a minimum, needing only one high performance optical smoke (H.P.O.) detector.
visit to complete the installation. The detectors The use of the patented optical sensing chamber,
also have a park position, which eases detector together with refined signal processing, has
servicing. enabled the introduction of a smoke detector
The unique smart key feature ensures that the suitable for fast, reliable smoke detection of both
address is transferred to the base after slow and fast developing fires. The H.P.O. can be
installation. This ensures that the detector seen as a truly universal smoke detector, suitable
addresses are not accidentally confused during for most applications.
* FM Approval pending at time of going to press
service visits.
Optical Smoke
These detectors are capable of Product Codes Approval Branded Model
detecting the visible smoke
516.057.001.A LPCB ADT MR901
produced by materials which
smoulder or burn slowly, i.e. soft 516.057.001.T LPCB Thorn MR901
furnishings, plastic foam etc;. or 516.057.001.Y LPCB Tyco MR901
'smoke' produced by overheated 515463 UL Grinnell 912P
but unburnt PVC. These detectors are particularly
suitable for general applications and areas where 516.057.031 UL Thorn 912P
cable overheating may occur e.g. electrical 516.057.032 ULC Thorn 912P-C
services areas. The novel design of the 516.057.401 Marine Thorn MR901M
asymmetrical sampling chamber and signal
processing techniques stop unwanted alarms
caused by very small insects. i.e. thrips. Smoke Datasheet - Product Code PSF84 “M600/900 Low
entering the sampling chamber scatters the infra- Profile Fire Detector Range”
red light pulses onto a photodiode These pulses Manual - Vol01B-03-D6 “Detectors Fire Manual”
are converted to an electrical signal which is
transmitted as an analogue value.
Page 41
tyco Fire & Tyco Electronic
Security Product Group
Heat
These detectors use two Product Code Approval Branded Model
networked thermistors in a bridge 516.053.001.A LPCB ADT MD901
configuration to provide a fast
516.053.001.T LPCB Thorn MD901
response, that depends both on
absolute temperature and notes 516.053.001.Y LPCB Tyco MD901
the change of temperature. The 516.053.002 UL Thorn 912H
rate of rise/fixed temperature heat detectors can 515461 UL Grinnell 912H
be used in areas where smoke sensors are
unsuitable due to environmental conditions
(smoke, dust etc,). Such areas include kitchens, Datasheet - Product Code PSF84 “M600/900 Low
locker rooms, canteens, garages, loading bays Profile Fire Detector Range”
etc.
Manual - Vol01B-03-D5 “Detectors Fire Manual”
The integral electronics emulate conventional fire
detector's response curves and transmit the state
to a controller as an analogue representation of
the ambient temperature conditions.
Technical Specification
Typical Dimensions of Standard 4” Detector
Page 42
tyco Fire & Tyco Electronic
Security Product Group
Page 43
tyco Fire & Tyco Electronic
Security Product Group
Conventional 600 Series Detectors
Body Optical Ionisation HPO R of R Heat FT CO Features
LPCB MR601 MF601 MR601T MD601 MD611 60°C MU601 • Unique early detection CO fire detector
NSTC MF601 MR601T • Intelligent Universal HPO Smoke Detector
• Low profile, discreet and unobtrusive
SSL/NZ* MR614 MF614 MR614T MD614 MU614
• Superior performance and reliability
UL/FM# 612P 612I 612HP 612H 622H 135°F • Attractive new design
632H 200°F • Designed for fast, easy installation
VdS MR613 MF613 MR613T MD613 MD623 • Optional Locking Kit
• Integral and remote alarm LED
Marine MR601M MF601M MD601 MD611
• Series of Product Approvals
*Available from Grinnell Detection Products in Melbourne & Grinnell Supply Sales N.Z. The M600 low Profile detectors can be custom
The M600 series are a range of low profile general purpose fire detector with unprecedented made in several colours, please contact the
conventional fire detectors. These unobtrusively early detection capability and excellent false alarm Walthamstow office for details
styled detectors have a number of unique design immunity. The CO fire detectors are the first
features to improve their operation, installation choice for sleeping risks.
and ease of servicing. Also included within the range is the intelligent
Through innovative design the M600 series high performance optical smoke (H.P.O.) detector.
detectors have reduced the installation and The use of the patented optical sensing chamber,
servicing time to a minimum, needing only one together with refined signal processing, has
visit to complete the installation and having a Park enabled the introduction of a smoke detector
position for the detector to ease the servicing. suitable for fast, reliable smoke detection of both
The M600 series includes the unique Carbon slow and fast developing fires. The H.P.O. can be
seen as a truly universal smoke detector, suitable # FM Approval pending at time of going to press
Monoxide CO fire detector, which provides a
for most applications.
Optical Smoke
These detectors are capable of Product Codes Approval Branded Model
detecting the visible smoke 516.056.001.A LPCB ADT MR601
produced by materials which
516.056.001.T LPCB Thorn MR601
smoulder or burn slowly, i.e. soft
furnishings, plastic foam etc;. or 516.056.001.Y LPCB Tyco MR601
'smoke' produced by overheated 561.0310 VdS Zettler MR613
but unburnt PVC. These detectors are particularly 516.054.041 VdS Thorn MR613
suitable for general applications and areas where
516.054.041.W VdS Wormald MR613
cable overheating may occur e.g. electrical
services areas. The novel design of the 515457 UL Grinnell 612P
asymmetrical sampling chamber and signal 516.056.031 UL Thorn 612P
processing techniques stop unwanted alarms 516.056.401 Marine Thorn MR601M
caused by very small insects. i.e. thrips. Smoke
entering the sampling chamber scatters the infra-
red light pulses onto a photodiode These pulses Datasheet - Product Code PSF84 “M600/900 Low
are converted to an electrical signal which is Profile Fire Detector Range”
compared against a preset alarm level. Manual - Vol01B-04-D6 “Detectors Fire Manual”
Page 44
tyco Fire & Tyco Electronic
Security Product Group
Heat
These detectors use two Rate of Rise
networked thermistors in a bridge Product Codes Approval Branded Model
configuration to provide a fast
516.052.001.A LPCB ADT MD601
response, that depends both on
absolute temperature and notes 516.052.001.T LPCB Thorn MD601
the change of temperature. The 516.052.001.Y LPCB Tyco MD601
rate of rise/fixed temperature heat 561.0340 VdS Zettler MD613
detectors can be used in areas
516.052.013 VdS Thorn MD613
where smoke sensors are
unsuitable due to environmental 516.052.013.W VdS Wormald MD613
conditions (smoke, dust etc,). Such 515453 UL Grinnell 612H
areas include kitchens, locker 516.052.031 UL Thorn 612H
rooms, canteens, garages, loading bays etc.
Fixed Temperature 60°C
The integral electronics emulate conventional fire
Product Codes Approval Branded Model
detector's response curves and transmit the state
to a controller as an alarm condition. 516.052.011.A LPCB ADT MD611
516.052.011.T LPCB Thorn MD611
Datasheet - Product Code PSF84 “M600/900 Low 516.052.011.Y LPCB Tyco MD611
Fixed Temperature 90°C Profile Fire Detector Range” 516.052.033 VdS Thorn MD623
Product Codes Approval Branded Model Manual - Vol01B-04-D5 “Detectors Fire Manual” 516.052.033.W VdS Wormald MD623
515455 UL Grinnell 632H 515454 UL Grinnell 622H
516.052.022 UL Thorn 632H 516.052.032 UL Thorn 622H
Page 45
tyco Fire & Tyco Electronic
Security Product Group
Page 46
tyco Fire & Tyco Electronic
Security Product Group
Standard Detector Bases
The Standard Universal detector bases are compatible with both conventional (M600) and analogue (M900) addressable detectors. The bases have no
electronics and even when the detectors are connected to the bases, they can be electrically disconnected and left in a “park” position. This enables wiring
integrity tests to take place without any damage to electronics. When used with addressable detectors, the smart card access key automatically transfers to
the base, thus the address remains with the base even if the detector is changed or replaced. An optional, tool removable locking pin allows the detector to be
fixed in place to prevent tampering.
6” Universal Base
The 6” base is specially designed for applications Product Codes
using the US style single gang backbox. The 6” 515468
base provides an alternative to the 4” base in 6B Lo Pro detector base (6”) Grinnell branded.
most applications and is particularly useful where 517.050.606
large holes in the ceiling need covering or where UL 6B Lo Pro detector base (6”) Thorn Security
ceilings suffer from condensation. branded. Suitable for use with LPC and Vds
Features approved detectors
• Variety of fixing options
• Sealed back and cable entry
• Remote LED connections
• Anti-tamper facility
• UL approved (6B)
Page 47
tyco Fire & Tyco Electronic
Security Product Group
Functional Detector Bases
Functional detector bases use a common moulding which incorporates a double side circuit board which enables electrical connections to be made on the top
and bottom of the functional base. This allows the functional bases to be retrofitted into new and existing universal bases or alternatively the depth and cost of
the installed detector can be reduced by using the functional base instead of the universal base. This feature enables additional line isolators and sounders to
be easily added during commissioning. In addition, changes to the building during it’s life can be easily adapted to, by retrofitting sounders and relay outputs to
existing detection points.
When functional bases are fitted to universal bases, they automatically lock into position. Removal is then achieved using the detector removal tool. This
feature ensures that the detector and functional bases are removed separately.
When used on addressable systems, the MC900 and MB900 take the same address as the detector. This increases the number of devices on a loop and
significantly improves fault monitoring. Any attempt to remove the functional base will generate a fault on the system.
Datasheet - Product Code PSF101 “M600/900 Low Profile Detector Bases”
Manual - Vol01B-06-D1 “Detectors Fire Manual”
mA MB600 MB900
25 50 48
20
20 40 36
15
15 30 24
10
10 20
5 10
Page 48
tyco Fire & Tyco Electronic
Security Product Group
MC900 & 900RBA Functional Relay Base
even when the relay is energised, enable the relay Vibration: Exceeds requirements of
base to be used without any additional power. On prEN54-3 Marine & UL268
addressable systems, the dual contacts operate Power Supply: Loop/Circuit
when the detector is in alarm OR when
Product Codes
commanded to do so by the panel.
568.001.016
Features
MC900 Relay base (BS 5839)
• Dual pole 24V d.c. relay contacts (60VA)
• Status indication LED 568.001.019
• Very low power consumption (<20µA except 900 RBA Relay base (UL -Thorn)
start up)
• Can be used in place of a standard base 515591
Technical Specification 900 RBA Relay base (UL - Grinnell)
Operating Temp.: -25 to 70°C
The 900 Series relay base provides dual relay
Humidity: Up to 96% RH (non-
contacts for signalling external devices on
condensing)
addressable systems. Very low operating current
Page 49
tyco Fire & Tyco Electronic
Security Product Group
M600/900 Detector Anciliaries
M600/900 Anciliaries
Page 50
tyco Fire & Tyco Electronic
Security Product Group
Duct Probe Air Sampling
MP/SMP Duct Probe Units withstand the more demanding environments of MP69 SMP69 MP35 SMP35
The MP/SMP Duct Probe Units are designed to the offshore oil and gas industries. Height 90mm 90mm 116mm 116mm
be installed in air conditioning supply and exhaust The units are designed to operate in airspeeds of Width 145mm 150mm 145mm 150mm
ducts for the purpose of monitoring the airflow for 1.5 to 25 metres per second. A range of sampling
Length 220mm 225mm 220mm 225mm
smoke and combustion products. tubes from 525mm to 1575mm is available
Weight 0.58Kg 1.2Kg 0.35Kg 1Kg
The MP69 and SMP69 probe units are designed Technical Specification
to accept and operate with the M600 and M900 Operating temperature: -20°C to +70°C
series detectors. MP35 and SMP35 duct probe
Storage temperature: -25°C to +80°C
units are available for use with M300 and M500
intrinsically safe series detectors and bases. For Relative Humidity: 0 to 95%
general applications it is recommended that MP## "Bayblend" housing with transparent
photoelectric smoke detectors rather than polycarbonate cover
ionisation smoke detectors are used. SMP## Stainless steel 316 housing with
The SMP stainless steel probe unit is designed to transparent polycarbonate cover
Warning Siting
Duct probe units sited in the common duct work to Duct probe units should always be sited as near to the point of extraction from the room as possible and
several extract grills may fail to respond to smoke in lengthy duct work runs, at intervals along the run. Probes should be mounted at the least turbulent
from any one extract due to the effect of dilution. sections of the ducting. Avoid installation immediately behind fans, bends or work sections.
The MP/SMP units will not respond to airflow of
less than 1.5m/sec.
Page 51
tyco Fire & Tyco Electronic
Security Product Group
Aspirating Smoke Detectors VESDA - Vision Systems
VESDA LaserPLUSTM, is a high sensitivity aspirating smoke detector. It provides both an early warning to facilitate intervention, and a suppression (Fire 2)
signal to initiate release at an appropriate level, eliminating the need for a separate detection system. The system is modular, displays and programmers can
be installed only where needed. Many VESDA products are also available from stock in German. German product codes are shown in brackets where they
exist.
Datasheet - Product Code PSF105 “VESDA LaserPLUS”
VESDA LaserCOMPACTTM
achieved through the combination of approved • Optional remote display and relay capability
LaserPLUS detection technology, dual stage • Simple mounting design
filtration technology and a modified aspirator • AutoLearnTM
design incorporated in a smaller enclosure with
simplified display. LaserCOMPACT is available in Technical Specification
two versions, one that interfaces via relays only Supply Voltage: 18 to 30Vd.c.
(RO) or across either the relays or VESDAnetTM Current Consumption:170mA quiescent,
(VN). 190mA in alarm
Features Dimensions: 225H 225W x x 85Dmm
• Reduced size Weight: 1.9Kg
• Absolute smoke detection Operating Temp.: -10oC to 39oC
• Wide sensitivity range Sampled Air: -20oC to 60oC
• Single pipe inlet Product Codes
• Simple display 516.018.010 (561.043)
• Referencing VLC-505 VESDAnet Version (VN)
• VESDAnet communication (VN) 516.018.011 (561.042)
The LaserCOMPACT detector has been
• Dual stage dust filter VLC-500 Relays Only Version (RO)
specifically designed to provide all the benefits of
• Three alarm levels See also Remote Displays
aspirating smoke detection, including very early
• Configurable relays
warning, in single environment small areas and
• Air flow monitoring
where space is a premium. This has been
516.018.013 (561.038)
VLP-400 LaserPLUS Detector with fire OK LED
Page 52
tyco Fire & Tyco Electronic
Security Product Group
LaserPLUS Scanners - 7 & 12 Relay Output Variants
VESDA LaserPLUS is also available in a Scanner Features Technical Specification
configuration, which allows the system to • Individual pipe annunciation Supply Voltage: 18 to 30Vd.c.
distinguish and identify the pipe carrying smoke, • Adaptive scan threshold Current consumption: (No display or programmer)
while sampling multiple sectors. • Wide sensitivity range (0.005 to 20% obs/m) 240mA quiescent plus 70mA
The VESDA LaserPLUS will continue to sample • Laser based light source alarm (24Vd.c. & 3000 rpm)
from all sectors to monitor the fire growth and • Configurable alarm levels Dimensions: 225H x 350W x 125D mm
maintain full protection. • Purpose built Aspirator Weight: 4.0Kg including display and
• 4 In-Line inlet pipes programmer modules
• Flow sensor for each pipe inlet Operating Temp.: 0oC to 39oC
• Low-cost maintenance Humidity: 10-95% RH, non condensing
• Dual stage filter Relay Outputs: 7 or 12
• Easy access to filter cartridge
• Recessed mounting
Page 53
tyco Fire & Tyco Electronic
Security Product Group
LaserPLUS Standard 19 Inch Sub-Rack Remote Display Assemblies
Product Codes 516.018.251
516.018.201 VSR-4000 19” Sub-rack with 1 scanner display
VSR-2000 19” Sub-rack with 1 detector display and 3 blank
and 3 blanks 516.018.252
516.018.202 VSR-4100 19” Sub-rack with 1 scanner display,
VSR-2100 19” Sub-rack, 1 detector display, programmer and 2 blanks
programmer and 2 blanks 516.018.253
516.018.203 VSR-4410 19” Sub-rack with 2 scanner displays,
VSR-2210 19” Sub-rack, 2 detector displays, programmer and 1 blank
programmer and 1 blank 516.018.254
516.018.204 VSR-4441 19” Sub-rack with 3 scanner displays
VSR-2221 19” Sub-rack with 3 detector displays and programmer
and programmer 516.018.255
The 19” sub-rack is available as a mounting
516.018.205 VSR-4443 19” Sub-rack with 3 scanner displays
option, with 4 mounting slots for display or
VSR-2223 19” Sub-rack with 3 detector displays and VESDAnet socket
programming modules.
and VESDAnet socket 516.018.256
Technical Specification
516.018.206 VSR-4444 19” Sub-rack with 4 scanner displays
Dimensions: 128H x 482W x 120D mm
VSR-2222 19” Sub-rack with 4 detector displays
Page 54
tyco Fire & Tyco Electronic
Security Product Group
LaserPLUS Spares
Product Codes 516.018.515
516.018.501 VSP-015 Spare aspirator fan
VSP-002 Display (spare) 516.018.516
516.018.502 VSP-016 Spare header termination card 12 relays
VSP-004 Scanner display (spare) 516.018.520
516.018.503 VSP-020 Set of spare plastic screw covers
VSP-001 Programmer (spare) 516.018.530
516.018.505 VSP-100 Spare blank plate for Fire OK models
VSP-019 Filter cover door (spare) 516.018.532
516.018.506 VSP-102 Spare detector relay processor
VSP-006 Spare detector chassis and manifold 516.018.533
516.018.508 VSP-103 Spare scanner relay processor
516.018.504 VSP-008 Spare remote termination card 7 relays 516.018.534
VSP-005 Filter cartridge (spare) 516.018.509 VSP-200 Spare blank cover
VSP-009 Spare scanner chassis and manifold 516.018.535
The following common VESDA LaserPLUS spares 516.018.513 VSP-003 Spare VESDAnet kit
are kept in stock by Tyco Electronic Product VSP-013 Spare plastic detector cover 516.018.536
Group. Other spares can be supplied if required. 516.018.514 VSP-208 Spare remote termination card - 12 relay
VSP-014 Spare header termination card 7 relays
Language VESDA Scanner VESDA Detector VESDA Remote Terminal VESDA Laser Compact
Swedish 516.018.270 516.018.280 516.018.290 516.018.310
French 516.018.271 516.018.281 516.018.291 516.018.311
Spanish 516.018.272 516.018.282 516.018.292 516.018.312
German 516.018.273 (571.088) 516.018.283 (571.087) 516.018.293 516.018.313
Italian 516.018.274 516.018.284 516.018.294 516.018.314
Flemish 516.018.275 516.018.285 516.018.295 516.018.315
Dutch 516.018.276 516.018.286 516.018.296 516.018.316
Finnish 516.018.277 516.018.287 516.018.297 516.018.317
Danish 516.018.278 516.018.288 516.018.298 516.018.318
Page 55
tyco Fire & Tyco Electronic
Security Product Group
Special Hazards Detectors
S200 Plus Triple IR Solar Blind Flame Detector
• True window test in detection area (i.e. not in Technical Specification
the edge of the window) Detector Material: Stainless Steel 316L
• Terminals provided for Remote LED
Dimensions: 167H x 167W x 89D MM
connection
• BASEEFA (CENELEC) certified with other Weight: 4.5Kg
approvals in process Gland Entry: 3 x 20mm
• Meets the requirements of EN54 Pt10 Metal Parts: Bright Stainless Steel 316 to
• Submitted for FM, DNV and LRS
(external & internal) to BS
• Very low power consumption (0.35mA)
1449 Pt 2
• Models available with Conventional or
Analogue Addressable interface (requires 2 Tag Label: Stainless Steel 316
core cable only) Range: 0.1m2 petrol at 50m
The new MINERVA S200 PLUS flame detectors • Models also available with relay or 4-20mA 0.4m2 petrol at 60m
are the latest Infrared solar blind and multi- outputs
channel infra-red flame detectors with low power Response Time: Field Selectable 3,6 and 12s
• Patented dual filter solar blindness for
consumption and high false alarm immunity. complete solar blindness Sensitivity: 3 range settings
The MINERVA S200 PLUS range of advanced • 100°field of view on IS versions Relative Humidity: 95% (100% intermittent)
flame detectors is the most comprehensive range • 90° field of view on Flameproof versions Enclosure to: IP 66 and IP 67
available.
For information on flame detector test equipment,
Features Unlike other flame detectors on the market the please refer to the detector test equipment
• Triple waveband infrared solar blind flame MINERVA S200PLUS is available in both section.
detection for optimum false alarm immunity Intrinsically Safe (EEx ia) and Flameproof (EEx d)
models. Approvals
• Unrivalled black body rejection over a wide
The intrinsically safe models are suffixed by the BASEEFA Approved models are suffixed ‘1’. At
range of source temperatures
letter " i " and meet the requirements of EN50020 the time of going to print approval status is as
• Range adjustable to 50 metres for a 0.1m-2
part 7 and are BASEEFA certified EEx ia IIC T5. follows:
petrol pan fire
• Discrimination of optical faults (dirty windows) As part of an intrinsically safe circuit, it is suitable NSTC: Approved
from other faults in the built-in self test for zones 0,1 and 2 where group IIC gases or LPCB: Approved
• Housing designed for easy installation of lesser hazards can be continuously present in LRS: Pending
cabling explosive concentrations.
DNV: Pending
• Flexible mounting and angular adjustment The flameproof models are suffixed by the letter
• 3 x 20mm field cable entries FM Approved models are suffixed ‘2’. At the time
"f" and meet the requirements of EN50018 and
• IP66/67 housing designed for external use of going to print FM Approvals are imminent.
are BASEEFA certified EEx d IIC T6. The
• Rugged stainless steel ANC4 LM25 alloy detectors are suitable for zones 1 and 2 where
housing and mounting bracket group IIC gases or lesser hazards can be Product Code
• Operating temperature range of -40 to 80°C intermittently present in explosive concentrations. 517.001.249
• Variable response times and sensitivity
Weidmuller Q500-4A00 for S241f+
settings
• Remote self test and range setting Datasheet - Product Code PSF102 “Minerva S200
Plus Series”
Approvals
Interface BASEEFA FM Product Codes
Conventional 4-20mA Addressable Relay Ex ‘ia’ Ex ‘d’ Ex ‘d’
S231i+ ✔ ✔ 516.037.004
S231f+ ✔ ✔ 516.037.003
S232f+ ✔ ✔ 516.037.015
S241i+ ✔ ✔ 516.038.004
S241f+ ✔ ✔ 516.038.003
S251i+ ✔ ✔ 516.039.004
S251f+ ✔ ✔ 516.039.003
S252f+ ✔ ✔ 516.039.015
S261f+ ✔ ✔ 516.040.002
S262f+ ✔ ✔ 516.040.012
Page 56
tyco Fire & Tyco Electronic
Security Product Group
S111 and S121 Series Flame Detectors
• Built in response indicator Connections
• High immunity to smoke, dust and grime S111 Milspec plug sealed into body
Technical Specification
Milspec mating socket with 2m of 4 core PVC
Material: Impact resistant moulded
insulated, braid screened PVC sheathed cable
plastic (light grey)
to DEF Std 61-12 Pts 4
Dimensions: 160H x 80W x 60D mm
(without bracket) S121 One 4 way, 2.5 mm heavy duty terminal
block
Weight: 0.6Kg
Product Codes
Gland Entry (S121): 1 x 20mm
516.009.006
Range: 0.1m2 petrol at 20m
S111 Infra-red Flame detector solar blind plug and
0.4m petrol at 40m
socket connection
Field of View: 85° min inclusive
516.009.008
The S111 and S121 (and variants thereof) are Response Time: 3 secs min, 5-10 secs typical
S121 Infra-red Flame detector solar blind screw
single sensor infra-red flame detectors with optical Supply Voltage: 15.5 to 25.5Vd.c. terminal connections
filtering, suitable for use outdoors in a wide range
Quiescent Current: 100µA max. at 20Vd.c. 516.009.014
of applications.
Alarm Current: 60 mA max S121 Infra-red Flame detector solar blind screw
Specifically designed for use in the demanding
environments of the onshore petro-chemical Operating Temp.: -30°C (-40°C with reduced terminal connections (Pyrotronics) FM Approved
industry, the S111 and S121 detectors incorporate range) to + 70°C 516.009.007
an abrasion resistant sapphire window in a Storage Temp.: -40°C to + 80°C S112 Infra-red Flame detector non solar blind plug
protective housing to meet IP65. Relative Humidity: 95% (100% intermittent) and socket connection
Features Enclosure to: IP65 516.009.015
• No false alarms from welding, sunlight or high Classification: BASEEFA EEx ia IIC T5 S122 Infra-red flame detector non solar blind
intensity lamps Suitable for use in zones 0,1 screw terminal connections
• Low maintenance costs and 2 where group IIC 516.009.019
• Quick response to carbon fires gasses or lesser hazards
• Good performance (20m) S122 Infra-red Flame detector non solar blind
are present in explosive
• Completely solar-blind for use outdoors screw terminal connections (Pyrotronics)
concentrations.
• High sensitivity with exceptional interference
BASEEFA Cert No.: Ex 812333
rejection Datasheet - Product Code PSF22 “S111/121 Infra
• BASEEFA approved EEx ia IIC T5 Red Flame Detector”
• Housing protection to IP65 Manual - Vol01A-04-D1/D2/D3 “Detectors Fire
• Integral stainless steel 316 mounting bracket Manual”
• 2 core interface to conventional fire systems
Page 58
tyco Fire & Tyco Electronic
Security Product Group
Intrinsically Safe Point Detectors
Features Technical Specification - M300/500Ex (Including base)
• Conventional and addressable I.S. systems
• Suitable for worst case (EEx ia IIC T5) MF300/MF500 MR300/MR500 MD300/MD500 MS300/MS500
• Tyco High Performance Optical (HPO) smoke
detector Dimensions 102.6Dia x 90H 102.6Dia x 96H 102.6Dia x 89H 102.6Dia x 74.5H
• Compatible with S231i+ plus flame detector Weight 0.3Kg/0.33Kg 0.3Kg/0.33Kg 0.28Kg/0.30Kg 0.275Kg
• Compatible range of I.S. callpoints Temperature -20oC to +70oC -20oC to +70oC -20oC to +70oC -10oC to +60oC
The System Designer must be familiar with Humidity 95% Non-condensing
BS5345, EN50 and BASEEFA certification and
have successfully completed an Appropriate M300 BASEEFA Cert. No.: EX88B2168X
recognised course in Intrinsic Safety. Design of M500 BASEEFA Cert. No.: EX89C2200X
the system requires that the designer has all the
MR301Ex, MR301TEx, MR300Ex base are CSA Approved Certificate No.: 2017002500004454
information concerning the installation correctly
documented. The nature of the Hazard must be BASEEFA certification designated for each There are two I.S. systems used by Tyco
defined by the customer and a survey carried out system it is essential that the certified devices are Electronic Product Group,
to determine the proximity of the safe area to connected with cables of the specified limits. System 601 and System 602
establish cable runs. These limits have been certified for specific
System 601 is for use in conventional fire
classifications of hazard in order that energy
The probability of a flammable mixture being detection circuits, and System 602 is for use with
storage is limited.
present is defined by a Zone Number. Flammable MINERVA analogue addressable circuits. Two
gases are classified in Groups and their minimum The number of devices connected to the barrier Sounder Systems, (one earthed and one isolated),
spontaneous ignition temperature is categorised and located in the Hazardous Area must always are available and either can be used with System
by Class. TEPG supplied equipment marked EEx be limited to not more than the listed maximum. 601 or System 602.
ia IIc T5 would be suitable for use in worst case When a mixture of devices is connected to any
conditions. Eg. Zone 0 (ia), Hydrogen (IIc), T5 one zone the numbers must be reduced in
Datasheet - Product Code PSF64 “Series
(100 deg C). The Fire Alarm Equipment and proportion to the ratio of the load presented to the
300/400/500 Fire and Smoke Detectors”
Safety Barriers should be placed as near as barrier. When a System includes the use of either
possible to the containment wall of the Hazardous IF500Ex, S231i+ or S251i+, it must be Manual - Vol01A* “Detectors Fire Manual”
Area. This minimises the cable lengths between remembered that the load they present to the * Section is indicated next to the product code.
the barrier and the Hazardous Area and thus the circuit is twice that of a detector. A mixture of
capacity to store energy. large and small load devices connected to a zone
In order that an Installation will comply with the will require a calculation for the number of allowed
detectors.
Page 59
tyco Fire & Tyco Electronic
Security Product Group
Heat Detectors
though less sensitive,alternative. For general use, the optimum response can be chosen for each
and particularly where the ambient temperature application.
may be low, a 'Rate-of-Rise' heat sensor is to be Product Codes
preferred. This type of sensor reacts to
516.023.002 (Vol01A-02-D7)
abnormally high rates of change of temperature
and provides the fastest response over a wide MD301Ex Grade 1 Rate of rise heat detector
range of ambient temperatures. A fixed 516.023.004 (Vol01A-02-D7)
temperature limit is also incorporated in these MD303Ex Grade 3 Rate of rise heat detector
detectors.
516.023.006 (Vol01A-02-D7)
In many environments, e.g. kitchens and boiler
MD305Ex Temperature range 2 heat detector
rooms, sudden, large changes in temperature are
considered 'normal'. Rate-of-rise detectors are 516.033.002 (Vol01A-03-D6)
generally not suitable in these cases and fixed MD501Ex Analogue Addressable Heat detector
If environmental conditions rule out the use of temperature [static] types should be used. Within
smoke detectors, then a heat detector of the type the broad classifications of 'rate-of-rise' and 'static'
MD300Ex Range may provide an acceptable, the MD300 range offers several versions so that
Flame Detectors
without sacrificing speed of response to flaming Product Codes
fires. In order to ensure full coverage, however, 516.022.001 (Vol01A-02-D6)
flame detectors do require direct line of sight to all
MS302Ex Infra-red flame detector
parts of the protected area.
(See S100 Flame detector test equipment)
Infra-red flame detectors such as the MS302Ex
and MS501Ex are designed to respond rapidly to 516.032.001 (Vol01A-03-D5)
fires which involve clean-burning fuels such as MS502Ex Addressable Infra-red flame detector
alcohol or methane, i.e. fires which would not be (See S100 flame detector test equipment)
detected by smoke detectors. The MS302Ex and
MS501Ex Flame Sensor, by virtue of its operating
wavelength and flicker discrimination, are
insensitive to normal environmental influences.
For outdoor use however, or in the presence of
Flame detectors, unlike smoke and heat
very strong infra-red sources, a solar-blind
detectors, do not rely on convection to transport
detector [e.g. the type S200Plus] should be used.
the fire products to the detector nor do they rely
The MS302Ex and MS502Ex Flame detectors
on a ceiling to trap the products. They can,
should, normally, only be used inside buildings to
therefore, be used to protect large open areas
supplement heat and smoke detectors.
Page 60
tyco Fire & Tyco Electronic
Security Product Group
H Series Heat Detectors
• Special versions can be used in any Zone 1 or 516.014.021
Zone 2 environment H601 60oC Fixed temp. Grade 1 (Remote LED
• Grade 3 to European Standard EN54 Part 5 Ind.)
1977
516.014.019
Technical Specification
H602 60oC Fixed temp. Grade 1 (Integral LED
Operating Voltage: up to 24V d.c.
Ind.)
Quiescent Current: zero
516.014.025
Alarm Current: Limited by internal 390 ohm
H604 60oC Fixed temp. Grade 1 (Integral LED
or 50 ohm resistor
Ind.) Intrinsically Safe - Simple Apparatus
Dimensions: 82mm dia x 41mm
516.014.018
Weight: 73gm
The and H900 range of fixed temperature heat H900 90oC Fixed temp. Grade 1
detectors are designed to operate at 60oC and Material: Cycolac ABS
516.014.020
90oC respectively. They are particularly suited to Operating temp. range: -20oC to +100oC
H902 90oC Fixed temp. Grade 1 (Integral LED
areas where rapid changes in temperature and/or Relative Humidity: up to 100% RH (Non Ind.)
high ambient temperature exist, together with Condensing)
unsuitable environmental conditions for smoke 516.014.025
Alarm Temp: H6XX: 60oC
detectors. This makes the detectors ideally suited H904 90oC Fixed temp. Grade 1 (Integral LED
for galleys, laundries etc. H9XX: 90oC Ind.) Intrinsically safe - Simple Apparatus
Features Product Codes
• Approved by Marine classification authorities 517.001.130 Datasheet - Product Code PSF108 “H Series
• Two wire supervised circuit DHM8 (including 2 x 20mm glands) Fixed Temperature Detectors”
• Draws no quiescent current 516.014.017
• Self re-setting H600 60oC Fixed temp. Grade 1
Page 61
tyco Fire & Tyco Electronic
Security Product Group
Intrinsically Safe Callpoints
A variety of Ex ‘ia’ Intrinsically safe callpoints are The IF500Ex is an Intrinsically safe addressable the CP540Ex is specifically designed for use with
available as standard using KAC and MEDC interface module. the IF500Ex. The IF500Ex is fitted inside the
callpoint housings. It can be used to interface simple apparatus to CP950Ex and the IF520Ex and BASEEFA
The CP220Ex is a conventional callpoint for use MINERVA analogue addressable systems, Certified as integrated units.
on BASEEFA Certified System 601. System 601 designed to BASEEFA Certified System 602.
is compatible with MINERVA 1 to 4, System 1700, The IF500Ex can interface to devices such as ‘H’
NT & MINERVA Addressable DM modules. Series detectors & T54B heat probes. In addition
Product Code
515.001.041
Spare key for IF520Ex callpoint and other
SM87PB models
517.001.120
System 601 EOL Unit (P-10)
514.001.052 514.001.053
CP950Ex MEDC weatherproof intrinsically safe IF520Ex EExia MEDC SM87PB Stainless steel
callpoint with integral analogue addressable heavy duty intrinsically safe callpoint push button
module with integral IF500Ex analogue addressable
module
Page 62
tyco Fire & Tyco Electronic
Security Product Group
Intrinsically Safe Barriers and Housings
The following section relates to a range of intrinsically safe barrier and isolator equipment for use with Tyco Electronic Product Group manufactured fire
detection systems. It essentially encompasses the relevant MTL 5000 and MTL 7000 series barriers plus the associated housing options as an alternative to
existing MTL 700 and MTL 3000 series equipment.
On all issues of intrinsically safe systems design, please refer to Manual 26A for guidance.
Datasheet - Product Code PSF24 “System 601/602 for Hazardous Areas”
Manual - Vol026A-02-D1 “Intrinsically Safe Systems 601 & 602 Manual”
Galvanic Barriers
MTL 5000
The MTL 5061 is a two channel interface for use When designing new systems or upgrading
with conventional fire and smoke detectors existing MTL 3000 series systems to MTL 5000
located in hazardous areas. This galvanic isolator series, please use the appropriate MTL “DX”
is CE marked, and replaces the MTL 3043 barrier series enclosure equipment.
option. It is suitable for connecting loads in Zone Product Codes
0, IIC, T4-6 hazardous areas if suitably certified.
517.001.244
The MTL 5021 Isolating sounder driver enables
MTL 5061 2 channel galvanic isolator for
an intrinsically safe sounder device located in the
conventional detector zone - used on BASEEFA
hazardous area, to be controlled from the safe
Approved System 601
area. The MTL 5021 barrier is designed as a CE
marked replacement for the existing MTL 3021 517.001.245
barrier. It has one channel and is suitable for MTL 5021 I.S. Sounder driver
connecting loads in Zone 0, IIC, T4-6 hazardous
area if suitably certified.
MTL 3000
The MTL3000 series interface units offer a S100 series, S231i+ ) automatic fire detectors and
compact and easy-to-use means for the CP220Ex intrinsically safe callpoints. The
communicating safely with conventional fire MTL3043 is not suitable for use with addressable
detectors and output devices in the hazardous fire detectors. For application guidance, refer to
area. The MTL3000 solution provides an the relevant documentation for system 601 and
alternative to the shunt-diode safety barrier where system 602.
isolation is essential or preferred or a high Product Codes
integrity earth is not readily available.
517.001.204
The MTL 3021 enables the intrinsically safe
SYS.601/602 MTL3043 Galvanic Isolation safety
sounder type IS28 (576.501.013) to be activated
barrier
from the safe area. An absolute maximum of 4 off
I.S28 sounders may be connected to each 517.001.203
MTL3021 unit. SYS.601/602 MTL3021 Galvanic Isolation safety
The MTL 3043 is used primarily with intrinsically barrier
safe conventional type (M300 series, H600 series,
Zener Barriers
MTL 7100
The MTL 7100 Series intrinsically safe shunt- during commissioning, maintenance and fault
diode safety barriers are innovative devices finding, thus avoiding the need for additional
designed to provide exceptionally high packing disconnect terminals.
densities, straightforward installation and Please note that this barrier is a direct alternative
simplified connection, commissioning and for the MTL 728+ barrier. Currently, there is no
maintenance facilities. The MTL 7100 Series direct alternative for the MTL 788+ barrier used
include secondary replaceable fuses. These are with the MINERVA addressable system. So
useful where there is the possibility of faults addressable MINERVA systems must use the
occurring during commissioning, which would existing MTL 788+ barrier and associated housing
otherwise blow the barriers’ internal safety fuses. option.
One secondary replaceable fuse for each barrier Product Code
channel is provided and is lower in value than the
517.001.246
safety related fuse. Fuses are packaged in small
mouldings which can be latched in a disconnect MTL 7128+ Zener safety barrier for conventional
position to break the safe and hazardous areas detection circuits designed in accordance with
System 601
MTL 700
The MTL700 series are 1 or 2 channel devices Product Codes
which pass the electrical signal from fire detectors 517.001.201
to the control panel or from the control panel to
SYS.601/602 MTL728 Single Channel Zener
the output device. The barriers limit the amount of
Safety Barrier.
energy to a level that cannot ignite explosive
atmospheres. The over-voltage protection 517.001.202
provided by a Shunt-Diode Safety Barrier is with SYS.601/602 MTL788 Dual Channel Zener Safety
reference to the safety barrier earth connection. It Barrier.
is therefore imperative that a HIGH INTEGRITY 546.004.005
EARTH is used for this type of barrier.
SYS601/602 Intrinsically safe sounder circuit
interface module
Page 63
tyco Fire & Tyco Electronic
Security Product Group
Safety Enclosures
DX Series Enclosures
The MTL ‘DX’ Series enclosure equipment is Product Codes
designed to house MTL 5000 isolating interfaces 517.001.248
and MTL 7000 series shunt diode safety barriers.
DX070 Enclosure MTL 5000/7000 series barriers
Enclosures are usually selected on the number of
units they will accommodate. The following table 517.001.247
shows the capacity of each of the enclosure DX170 Enclosure for MTL5000/7000 series
types. barriers
Enclosure MTL5000 Isolators 16mm Pitch MTL7000 Barriers 7.5mm Pitch
DX070 4 (2*) 9 (5*)
DX170 10 (8*) 22 (18*)
* Use these figures when two IMB57 mounting brackets for tagging/earth rail accessories are included
UC Series Enclosures
The UC series of enclosures provides a simple Product Code
but effective means of mounting and protecting 517.001.196
the MTL3000 series units, in safe areas. Two
SYS.601/602 UC2 4, Way Barrier housing
standard lightweight enclosures with transparent
lid are available, which can accommodate either 4
or 8 units. The polycarbonate enclosures are
impact resistant, flame retardant, and dustproof to
IP65.
MT Series Enclosures
The MT series of enclosures provides a simple, Product Codes
effective means of mounting and protecting 517.001.198
MTL700 Series barriers in safe areas or low-risk
SYS.601/602 MT2 2,Way Zener Barrier Housing.
hazardous areas. Three lightweight polycarbonate
enclosures with see through lids accommodate up 517.001.199
to 2, 5 and 12 barriers in the safe area. All the SYS.601/602 MT5 5,Way Zener Barrier Housing.
enclosures are supplied ready fitted with a nickel 517.001.200
plated brass busbar mount, so barriers can be
SYS.601/602 MT12 12,Way Zener Barrier
installed and wired up immediately without special
Housing
tools.
Ancillaries
The ERL7 earth rail is a nickel plated 3 x 10mm Product Codes
rail (1 metre long), suitable for a do-it-your self 517.001.205
mounting arrangement. It will accommodate up to
SY.601/602 ERL7 Earth rail I.S. systems
2.5 ETM7 earth terminals per barrier location for
terminating earth returns and cable screens from 517.001.206
the hazardous area. SY.601/602 ETM7 Earth termination connection
The EBB7 earth busbar is nickle plated brass, and system
ready drilled for MTL700 series devices, and in 1 517.001.207
metre lengths. The IMB7 mounts on a flat surface SY.601/602 IMB7 Insulating mounting block
or top hat rail (35mm) or G-profile rail and acts as
517.001.216
a convenient method for mounting the earth
busbar. SY.601/602 EBB7 Earth bus bar
517.001.120
System 601 EOL Unit (P-10)
Page 64
tyco Fire & Tyco Electronic
Security Product Group
Beam and Linear Heat Detectors
Technical Specification Voltage Range- Fireray 2000 +11.5 to +28Vd.c.
Dimensions(mm) Weight LPBD521 28V Loop Power
Height Width Depth (Kg) Fireray 2000 Quiescent Current <13mA
Transmitter/Receiver 95 75 115 0.4 Fireray 2000 Alarm Current <20mA
Control Unit 260 210 80 2.25 Operating Temp. Range - Fireray -10oC to +55oC
LPBD521 (with M520 encl.) 87 148 14 0.1 LPBD521 -20oC to +70oC
Humidity up to 95% RH
(Fireray 2000 & LPBD521) (Non-condensing)
Fireray 2000 Enclosure IP54
Page 65
tyco Fire & Tyco Electronic
Security Product Group
MXF Optical Fibre Temperature Sensing
Features Technical Specification
The MXF100 system complies with:
• Fibre optic sensor loop up to 2km • EMC Directive 89/336/EEC
• Continuous temperature profiles of • Low Voltage Directive 72/2/EEC
temperature on a PC The MXF100 contains a Class 3a Laser product
• Programmable functions and complies with:
• BS7192 (1989)
• Programmable number of fire detection zones • American National Standard Z136.2 (1988)
• Multiple and programmable Alarm levels per • International Electrotechnical Commission
fire detection zone Standard 825 (1990)
• Variable rate of rise function Dimensions: 260H x 427W x 95D mm
Weight: 4.0Kg
• Unrivalled response times
This new technology uses a laser light source to Supply Voltage: 24V d.c. (-6/+12V d.c.)
launch light signals into the optical fibre. As • Optional outputs Power Consumption: 20W max
pulses travel down the fibre, energy is lost through • Modbus Serial Data Supply Current: <1A
scattering. A fraction of the scattered signal is Fuse Rating: <2A (anti-surge)
retained within the fibre. A portion of this is • Direct to PC
Fibre: 62.5/125 graded index multi-
directed back along the fibre towards the laser mode
• Volt free contacts
source - this signal is called backscatter. Part of
Operating Temp.: 0oC to +40oC
the back scatter signal (Raman Scattering) is • Insensitive to EMI
used to provide accurate remote temperature Storage Temp.: -40oC to +65oC
• Intrinsically safe sensor Humidity: 0 to 95% RH (non-
measurements at hundreds of points along the
fibre. • Uses standard communications grade optical condensing)
The MXF100 uses standard communications fibre Product Codes
grade optical fibre of the 62.5/125 graded index 516.016.101
• Choice of cable construction
multimode type. The temperature range is MXF100 Fibre Optic Linear Heat Detection control
predominantly a function of the coating used to • Cable construction for extreme environments unit
protect the optical fibre as the fibre itself is well 516.016.102
• High System Integrity
behaved over a temperature range from -50oC to MXF-ACS 62.5/125 single strand acrylate coated
approximately 300oC. Coatings have been tested • Automatic failure mode analysis multi-mode fibre 1Km reel
down to -190oC (acrylate) and up to 460oC
• Loop break recovery operation 516.016.103
(metallic).
MXF-ACS 62.5/125 single strand ribbon/dog-bone
Optical fibre itself offers several advantages as a • Diagnostic capability acrylate coated multi-mode fibre 1Km reel
sensing medium. The signals are immune to
• Fire progression monitoring Stainless steel clad fibre also available.
electromagnetic interference thereby ensuring
integrity of readings from electrically noisy areas. • No cable maintenance 516.016.104
As no electrical current is used in the sensing MXF-SSS 62.5/125 Single strand, stainless steel,
fibre and the fibre is relatively inert and dielectric • Modem for remote communications 316L sheath, multimode fibre 1Km reel
(non-conducting) medium, it is safe technology to
use in hazardous environments. Datasheet - Product Code PSF111 “MXF100
Optical Fibre Temperature Sensing Technology”
OPTICS
CONTROL
OPTICS
SIGNAL CONTROL
RELAY PCB1
POWER DATA
SUPPLY ACQUISITION
RELAY PCB2
RELAY PCB3
POWER SIGNAL
DATA
PROCESSOR
ELECTRONICS
Page 66
tyco Fire & Tyco Electronic
Security Product Group
Detector Test Equipment
Point Detector Testing/Commissioning Equipment
Manual - Vol01A & Vol01B “Detectors Manual”
Product Codes
517.001.230
SOLO100 Telescopic pole 1.26M to 4.5M long
517.001.226
SOLO101 Extension tube 1.3M long for use with
517.001.230 telescopic pole Product Code Product Codes
517.001.228 517.001.225 517.001.241
SOLO600 Carry all bag for detector test kit SOLO302 Aerosol dispenser for use with all SOLO451 Cordless heat detector tester kit
detector ranges. Connects directly to including SOLO450 tester, SOLO720 battery
SOLO100/101 poles batons and SOLO721 charger. Connects directly
to SOLO100/101 poles
517.001.242
SOLO720 Spare battery baton for use with
SOLO450 tester
517.001.243
SOLO721 Spare mains/car battery charger for
SOLO720 battery baton
Page 67
tyco Fire & Tyco Electronic
Security Product Group
SOLO TEST EQUIPMENT FOR POINT & FLAME DETECTORS
S111/112/121/122
S131/161 MS300/500 S200+
517.001.233
TEST CO & SMOKE DETECTORS
517.001.229
592.001.014
FPA18 AEROSOL
592.001.007 592.001.004 592.001.005 T210 517.025.026 DISPENSER
ADAPTOR TYPE 35 SKIRT 517.130.007
T110 TRS SURVEY CUP
ADAPTORS CHANGER HEAD
517.130.008
592.001.013 517.050.004 DETECTOR CHANGER HEAD
T210 M69 DETECTOR
CHANGER 517.001.225 517.001.032
592.001.012
T110 SOLO302 SOLO704
AEROSOL ADAPTOR TUBE D
DISPENSER
517.001.224
SOLO704
ADAPTOR TUBE B
517.001.226
SOLO101 EXTENSION
POLE 1.13m
517.001.230
SOLO100 TELESCOPIC
EXTENSION POLE SET
1.26m TO 1.45m
517.001.228
SOLO600 CARRYALL BAG
592.001.013 592.001.014
T210 Test source for use with (517.001.224) T210 Adaptor S200
SOLO 704 Adaptor Tube B and SOLO100/101
poles (517.001.230/226)
Page 68
tyco Fire & Tyco Electronic
Security Product Group
CP Series Callpoints
A comprehensive range of callpoints for use with addressable callpoints Datasheet - Product Code PSF36 “CP200 Series
both conventional and addressable systems. All • Test key facility, speed maintenance visits Break Glass Detectors”
the callpoints are designed to enable an alarm • Optional transparent hinged cover Manual - Vol08A-02-D9/D10/D27 “Ancillaries
signal to be given by breaking a glass element, • Hazardous areas models available (See Manual”
this operates a switch and is indicated by an LED Special Hazards Section)
indicator. If required, an optional transparent • IP66 Waterproof models for external
hinged cover may be installed to guard against applications
accidental operation. Technical Specification - (Indoor & Outdoor)
Features Housing: Modified Polyphenylene
• Integral LED indicator for easy identification of Oxide[Noryl SE100]
operation Operating Temp.: -20oC to +70oC
• Surface or flush mounting Relative Humidity: up to 95% RH (non-
• Extensive range of conventional and analogue condensing)
Commonly Used Callpoints
Model Colour Function Marking Type IP Range R1/R2 Ohms
CP200 Red Fire Conventional Alert 44 120/470
CP210 Red Fire Evacuate Conventional Evacuate 44 49/39
CP230 Red Fire Conventional Alert 66 120/470
CP270 Yellow Evacuate Conventional Evacuate 44 47/39
CP920 Red Fire Addressable 44 Not Applicable
CP930 Red Fire Addressable 66 Not Applicable
CP937 Red Fire Addressable 55 Not Applicable
Keyswitch White Bomb Alarm Conventional 44 Not Applicable
Callpoint Dimensions
Indoor Callpoint Outdoor Callpoint (IP66)
Weight: 200g Weight: 400g
59mm
Conventional Callpoints
Typical Conventional Wiring
Typically the conventional callpoint devices draw
no current in the ‘off’ state, but when activated, will
R2 R1 R2 R1 present an alarm load to the fire detection control
panel. The alarm load is defined by the internal
+ resistance arrangement for the device.
IN OUT
- + - +
Black Red
Flying Leads
Callpoint
Page 69
tyco Fire & Tyco Electronic
Security Product Group
Conventional CP200 Callpoint
The CP200 is a red indoor callpoint with ‘alert’
resistors and LED indicator. The CP200 is LPCB
approved.
Product Codes
514.001.042.T
CP200 without backbox, English ‘Fire’ marking
and Thorn Security branded lid
514.001.042.Y
CP200 with backbox, English ‘Fire’ marking and
Tyco branded lid
514.001.057
CP200E without backbox, European ‘Fire’ marking
and glass, unbranded lid
90-110
Standard KAC KR-1 Flush Callpoint (No resistors
fitted)
514.001.042.A 514.001.006 70-133
CP200 without backbox, English ‘Fire’ marking CP200A complete with surface backbox. Arabic Standard KAC KR72-680 Flush Callpoint
and ADT branded lid English ‘Fire’ marking. Thorn Security branded (680 Ohms resistance)
Page 70
tyco Fire & Tyco Electronic
Security Product Group
CP920 MINERVA Addressable Callpoint
The CP920 is a red addressable callpoint with
‘Fire’ marking and LED indicator. The CP920 is
LPCB approved and supplied without backbox.
Product Codes
514.001.049.A
CP920 ADT branded
514.001.049.T
CP920 Thorn Security branded
Callpoint Ancillaries
Product Codes
90-106
Test keys for all CP200/500/900 callpoints except
CP950Ex
90-107 515.001.005
Red M141 spacer for red CP2/900 KAC callpoints Hammer on chain (for use with any breakglass
callpoints)
515.001.028 515.001.026
Callpoint hinged cover for use on CP200 and 900 Black callpoint bezel for CP200/500/900
models
Page 71
tyco Fire & Tyco Electronic
Security Product Group
STOPPER
The callpoint STOPPER provides protection from
malicious or accidental activation of manual
callpoints. Available for flush or surface mounted
callpoints the ‘STOPPER’ is also available with
optional high pitch sounder which is activated
when the lid is lifted.
An optional ‘Break-Seal’ fitting kit allows ‘Break-
Seals’ to be used to provide extra protection.
WARNING:-Break seals only to be fitted by
agreement with relevant fire authorities.
The STOPPER is suitable for all callpoints up to
100mm square, including CP820, CP920, CP200 Product Code
and other indoor KAC style callpoints. 515.001.033
IPO36 Break Seal Kit
STOPPER Dimensions
Millimeters
A 137
B 140
C 104
D 45
E 12.5
F 12.5
G 185
H 12.5
STOPPER STOPPER II
Max. Callpoint Size 100 x 100mm 160 x 160 mm
STOPPER II Dimensions Max. Callpoint Depth 57.5 120
(+30mm Surface)
Millimeters
A 70
B 16
C 197
D 50
E 178
F 146
G 228
H 254
Stopper II Surface Fit - STI1230
Page 72
tyco Fire & Tyco Electronic
Security Product Group
STOPPER II
STOPPER II is constructed as the STOPPER from Product Code
tough injection moulded polycarbonate. Physically 515.001.034
larger than the STOPPER the STOPPER II STI1230 Surface fit STOPPER II
extends the number of products to which these
tough multi-purpose covers can protect.
It consists of a strong tamper-proof clear
polycarbonate cover and frame that fits easily
over such products as break glass callpoints. The
STOPPER II can also be fitted with an integral
battery powered sounder which activates if the
cover is lifted.
The STOPPER II is suitable for callpoints up to
160mm square like the DIN820/830 and CP830.
Product Code
516.015.009
STI9625 Smoke beam/CCTV guard
Extinguisher STOPPER
The Extinguisher STOPPER is a self powered Product Codes
electronic security device which can be installed 515.001.038
and protecting fire extinguishers in minutes. The STI6200 Extinguisher STOPPER
Extinguisher STOPPER is an effective way to stop 515.001.042
vandalism, misuse or theft. This simple self STI6205 Operating cable kit
contained device incorporates a unique and
patented steel cable operated switch mechanism,
which activates a piercing alarm when the
extinguisher is removed from its normal position.
One end of the operating cable is crimped and
secured around the neck of the extinguisher and
inserted into the alarm unit. If the operating cable
is detached from the unit a 10dB sounder is
activated.
Exit STOPPER
The Exit STOPPER is a completely self contained are also options for remote and double door
and self powered security device to protect and installation.
deter the unauthorised use of emergency exit The unit comes complete with low battery
doors. It is a versatile, reliable and extremely easy warning, automatic reset facility, a choice of
to install electronic door alarm. If the door is steady pulsating tones, a 9V long life alkaline
opened the Exit STOPPER activates a 110dB battery and installation pack.
electronic sounder. A key operated over-ride
facility is incorporated into the front of the unit, Product Code
which will allow authorised use of the emergency 515.001.037
door. STI6400 Red Exit STOPPER
The Exit STOPPER is injection moulded in flame
retardant polycarbonate and can be easily
installed on wooden, glass or metal doors. There
Page 73
tyco Fire & Tyco Electronic
Security Product Group
Keybox
This tough polycarbonate breakglass keybox is
available to protect emergency keys and
documents.
Product Code
515.001.039
STI6720 Keybox with printed glass
515.001.010
Walsall callpoint glasses (Pack 10) for services
spares. The Walsall callpoint is an old square
callpoint with round glass
Page 74
tyco Fire & Tyco Electronic
Security Product Group
MINERVA Range of Sounders
A range of sounders to meet a wide variety of Features • Weatherproof units for outdoor use
alarm applications where loud, penetrating and • Wide range of both bells and electronic • Distinct sounds are available
distinctive warning must be given to alert people sounders • Motorised and Solenoid bells available
of fire situations. In addition, multitone electronic • High sound output characteristics • Wide range of voltages available
sounders can give a variety of sounds to signal • Low current consumption • Addressable Loop Powered Banshee
other conditions e.g. “extinguishing gas release • Clean lines, modern styling
imminent”, etc. • Easy to install, low installation costs
Datasheet - Product Code PSF11 “Audible Alarms”
Banshee Loop Powered* 0.30 IP45/66 See note below 100 800-950 B
Bells
6” Red Solenoid Operated Friedland Bell
The bells are the underdome type, with a high with ADT branding
resonance pressed alloy-steel gong to ensure a 576.500.009.T
loud clear-tone ring. The operating mechanism is
24V Bell 6” 24V d.c. solenoid operated.‘Fire’ text
fully enclosed and the gong is red stove
with Thorn branding
enamelled for long life. The bells are designed for
internal use, but gasket sealed conduit boxes can 577.001.002
be provided for external use. BELL WP BOX Weatherproof gasket box 6” for
Product Codes use with Solenoid operated bells
576.500.004.A
240V Red bell 6” 240Va.c. solenoid operated.
‘Fire’ text with ADT branding
576.500.004.T
240V Red bell 6” 240Va.c. solenoid operated.
‘Fire’ text with Thorn branding
576.500.009.A
24V Bell 6” 24V d.c. solenoid operated. ‘Fire’ text
Motorised Bells
Features Product Codes
• CE marked 576.501.039.A
• Low current 6” bell (ONLY 15MA) MBF-6WE ADT Branded
• Low cost
• Extra high 94dBA/m 576.501.039.T
• Slim profile (53mm) MBF-6WE Thorn Branded
• Fully suppressed and polarised 576.501.040.T
• Quick and easy to install MBF-8WE Thorn Branded
Model MBF-6WE MBF-8WE
576.501.040.A
Rated Voltage 24V d.c. 24V d.c.
MBF-8WE ADT Branded
Rated Current 15mA 30mA
Other branding available on request
Sound output 94dBA 95dBA
Operating Temp -10 to +50°C
Colour Red
Weight 720g 1420g
Page 75
tyco Fire & Tyco Electronic
Security Product Group
Electronic Sounders
Banshee/Bedlam
An ultra low profile alarm sounder for fire and • Volume Control
security applications utilising all of the best • Side and Rear cable entry
features of the traditional Banshee plus an • Optional Deep base
additional volume control fitted as standard. The • Loop in out terminals
low profile unit has been designed to complement Sound Options:
new building interiors and is available in red or Buzz: Very fast sweep at approx 120Hz
white. Fast Sweep: 800Hz-950Hz, sweeping 9 /Sec
Features Slow sweep: 800Hz-950Hz, sweeping 3/Sec
• Ultra Low Profile Continuous: 850Hz
Product Code Branded Colour Power Freq dB Alarm Current Weatherproof
Banshee 576.501.004.A ADT Red 24V 800-950Hz 107 15mA No IP44
576.501.008.A ADT Red 24V 2.5-3KHz 105 25mA No IP44
576.501.033.A ADT White 24V 800-950Hz 107 15mA No IP44
576.501.024.A ADT Red 24V 800-950Hz 107 15mA Yes IP66
576.501.015.A ADT Red 24V 2.5-3KHz 117 30mA Yes IP66
576.501.004.T Thorn Red 24V 800-950Hz 107 15mA No IP44
576.501.008.T Thorn Red 24V 2.5-3KHz 105 25mA No IP44
576.501.033.T Thorn White 24V 800-950Hz 107 15mA No IP44
576.501.024.T Thorn Red 24V 800-950Hz 107 15mA Yes IP66
576.501.015.T Thorn Red 24V 2.5-3KHz 117 30mA Yes IP66
576.501.004.Y Tyco Red 24V 800-950Hz 107 15mA No IP44
576.501.033.Y Tyco White 24V 800-950Hz 107 15mA No IP44
Sound levels are quoted on E-SPL Effective Sound Pressure Level @1 Metre which is the output in a
typical room setting. 117dB models are known as Bedlam sounders
Weatherproof Banshee Line Powered Banshee
The LPBB521 Line powered Addressable is low frequency [800-950hz]. The Sounder
Sounder is designed to be driven from a Loop output is set to Fast Sweep, but may be pulsed
Powered MINERVA Analogue Addressable under the control of the MINERVA.
controller via the addressable loop. The sounder Quiescent Current: 0.52mA
Product Code Branded Colour Power Freq dB Alarm Current Weatherproof
577.001.026.A ADT Red Loop LF 100 17mA No IP44
577.001.029.A ADT White Loop LF 100 17mA No IP44
577.001.026.T Thorn Red Loop LF 100 17mA No IP44
577.001.029.T Thorn White Loop LF 100 17mA No IP44
577.001.026.Y Tyco Red Loop LF 100 17mA No IP44
577.001.029.Y Tyco White Loop LF 100 17mA No IP44
Accessories
The combined mounting bracket for the Besson Product Codes
Bedlam
Banshee and Xenon Beacon allows quick and 576.501.041
neat installation of combined sounders and
Banshee/Xenon bracket
beacons. The bracket allows the following
Banshee/Xenon Bracket 576.501.042
electronic sounders to be mounted with the range
of 1W Xenon Beacons: Banshee IP66 backbox for use with loop powered
• Besson Banshee banshees and FIRECRYERS
• Besson Bedlam 577.001.006
• Loop powered MINERVA Besson Banshee Flush mounting bracket for use with low profile
• MINERVA FIRECRYER voice enhanced banshees - white
sounder
576.501.011
The bracket can be used with any of the 24Vd.c
1W Xenon beacons in red, clear, amber or blue Banshee/Bedlam weatherproof mains adaptor
(Part no.'s 540.001.030/031/032 & 033) pack 240Va.c. to 24Vd.c. use on any 24Vd.c.
Banshee or Bedlam
Banshee Flush Mount Bracket
Besson Wafer Sounder
The standard Besson Wafer sounder is supplied in Technical Specification
white with a blank cover included. The Current: 4mA to 15mA
specification is as follows:
Temperature Range: -40°C to 70°C
Input voltage: 24V d.c. (+/-25%)
Dimensions: Dia 103mm, Height 22mm
Sound Output: 60dBA/90dBA at 1m typical (pot. (excluding coverplate)
Adjustable) offering the same sound formats as
Product Code
the Banshee sounder range. It can therefore be
used in conjunction with the Banshee sounders on 576.501.038
the same site Besson wafer sounder and blank cover in white
Besson Wafer Sounder Flush Mount Bedroom Sounder
Meeting the requirements for BS5839 part 1, the • Can be both Flush and Surface mounted
Bedroom Sounder range is well suited to hotels • Robust terminal connectors to accommodate
and residential environments where aesthetics is a up to 2.5mm2 conductors
prime concern. Matching the sound output of the Product Codes
Banshee range of sounders so therefore can be 576.501.032.A
mixed on a site.
Flush Mount Sounder ADT Branded
Features
576.501.032.T
• Low current consumption 7mA
Flush Mount Sounder Thorn Branded
• Dual sound options selected via a jumper
Flush Mount Sounder switch: ‘Continuous’ and ‘Fast Sweep’ 90dB
Page 76
tyco Fire & Tyco Electronic
Security Product Group
Banshee Slow Whoop
This sounder has the same features as the
standard Banshee sounder but comes with a slow
whoop sound as standard to meet the
requirements of the Dutch Market.
Product Code
576.501.019
24Vd.c. slow whoop low profile red dutch
Banshee IS28
Product Codes
576.501.013
IS28VCL Banshee IS28 BS5839 low frequency
BASEEFA certified intrinsically safe Grey sounder
- 98dBA, 10mA. Certificate number. Ex87B2027
EExia IIC T5 suitable to replace Banshee IS22B
576.501.018
IS28VCH Banshee IS28 high frequency
BASEEFA certified intrinsically safe red sounder -
104dBA, 18mA. Certificate No. Ex87B2027 EExia
IIC T5
Yodalarms
This versatile range of sounders are ideally Product Codes
suitable for fire, safety and security hazard 576.501.001
warning.
YO3 Yodalarm 3” 24Vd.c. 100dB @ 1Mtr
Technical Specification
576.501.002
Dimensions:
YO5 Yodalarm 5” 24Vd.c. 106dB @ 1Mtr
YO3: 89H x 89W x 85D mm
576.501.003
YO5: 134H x 134W x 128D mm
YO8 Yodalarm 8” 24Vd.c. 112dB @ 1Mtr
YO8: 216H x 216W x 153D mm
Page 77
tyco Fire & Tyco Electronic
Security Product Group
Fulleon Range of Sounders
NOTE: All typical sound output values used are as tested in fully anechoic conditions to prEN54-3. In practical semi-reverberant conditions outputs may be up to
5dB(A) higher dependent on the tone employed.
Roshni
A flexible alarm sounder for Fire and Security Output Voltage: 9-28Vd.c.
applications complete with volume control and dil Typical Current: 24Vd.c.@16mA
switch to provide 32 tones. Typ. Sound Output: @1m 102dB (A)
- Tone 2 similar to Banshee fast sweep Product Codes
- Tone 1 similar to Banshee slow sweep ROSHRDSR
Low profile Roshni with Deep base offers IP65 ROSHNI Sounder deep base - red
protection. All Roshni sounders have synchronised 171.392
start for self synchronisation without third wire. ROSHNI Sounder deep base - white
Technical Specification
Dimensions: 93 Dia x 105D mm
(Deep base)
Colour: Red or white available
Approvals: None (Approved variants
available)
Squashni
The Squashni electronics sounder is the original Product Codes
ceiling sounder for use as a universal fire detector 20-116
platform or as a stand alone sounder complete SQ/H/3 Squashni Hochiki white sounder base set
with blank cover. It comes complete with 28 pre- to tone 3
set tones and volume control and is fully 576.501.030
compatible with Roshni tones, synchronised start. Squashni white 24Vd.c.
Technical Specification 576.501.031
Dimensions: 112 Dia x 27D mm Blank cover plate white for Squashni
Colour: Matched to leading fire
detector manufacturers
Approvals: None (Approved variants
available)
Output Voltage: 9-28Vd.c.
Typical Current: 24Vd.c.@16mA
Typ. Sound Output: @1m 93dB (A)
Askari Compact
The Askari Compact is a compact bedroom Product Codes
sounder for unobtrusive installation. It comes ASKR
complete with 28 pre-set tones and volume control Askari sounder - red
and is fully compatible with Roshni tones, ASKW
synchronised start. Includes matching backbox for Askari sounder - white
surface mounting.
Technical Specification
Dimensions: 87.5H x 85.75W x 36D mm
Colour: Red or white available
Approvals: BS 5839 pt 1
Output Voltage: 9-28Vd.c.
Typical Current: 24Vd.c.@16mA
Typ. Sound Output: @1m 95dB (A)
CF Motorised Bells
The CF Motorised bells are low current, fully Product Codes
suppressed and polarised. 576.501.022.A
Technical Specification 6" Bell 24Vd.c. motorised. 'Fire' text with ADT
Dimensions: 4, 6 & 8” Diameter available Branding
Colour: Red (other colours available 576.501.022.T
to order) 6" Bell 24Vd.c. motorised. 'Fire' text with Thorn
Output Voltage: 18-30Vd.c. Branding
Typical Current: 24Vd.c.@22mA 576.501.023.A
Typ. Sound Output: @1m 94dB (A) 8" Bell 24Vd.c. motorised. 'Fire' text with ADT
Branding
576.501.023.T
8" Bell 24Vd.c. motorised. 'Fire' text with Thorn
576.501.022.A Branding
576.501.023.A
Page 78
tyco Fire & Tyco Electronic
Security Product Group
Flashni
Combined sounder and beacon, combines the Product Code
features of the Roshni electronic sounder with a 20-118
fully integrated Xenon beacon. These sounders Combined Roshni sounder/strobe complete with
are fully compatible with all Roshni tones, deep base
automatic sounder synchronisation. Weather
resistant to IP65.
Technical Specification
Dimensions: 93 Dia x 92D mm
(Shallow base)
93 Dia x 121D mm
(Deep base)
Output Voltage: 18-30Vd.c.
Typical Current: 24Vd.c.@68mA
Typ. Sound Output: @1m 101dB (A)
No. 1st TONE 2nd TONE TYPICAL (mA/24V) TYPICAL SOUND OUTPUT(dB @ 1m)
1 ALT TONES 800/970 at 1/4 Hz 14 18 104
2 SWEEPING 800/970Hz at 7Hz 14 19 105
3 SWEEPING 800/970Hz at 1Hz 14 18 105
4 CONTINUOUS at 2850Hz 14 29 116
5 SWEEPING 2400-2850Hz at 7Hz 4 23 114
6 SWEEPING 2400-2850Hz at 1Hz 4 23 113
7 SLOW WHOOP 14 15 103
8 SWEEP 1200-500 at 1Hz 14 16 103
9 ALT TONES 2400/2850 2Hz 4 27 113
10 INT TONE OF 970Hz at 1Hz 14 1 106
11 ALT TONES 800/970 Hz at 1Hz 14 18 105
12 INT TONE at 2850 Hz at 1Hz 4 20 116
13 970Hz at 1/4 SEC. ON 1 SEC. OFF 14 7 102
14 CONTINUOUS AT 970Hz 14 20 107
15 554 FOR 100ms and 440Hz FOR 400ms 14 12 99
16 INT 660Hz 150ms ON/150ms OFF 16 9 87
17 INT 660Hz 1.8s ON/1.8s OFF 17 12 91
18 INT 660Hz 6.5s ON/13s OFF 18 10 90
19 CONTINUOUS 660Hz 19 14 90
20 ALT 554/440Hz at 1Hz 20 13 95
21 INT 660Hz 1Hz 21 9 87
22 INT 2850Hz 150ms ON 100ms OFF 14 19 113
23 SWEEP 800-970Hz at 50Hz 14 18 105
24 SWEEP 2400-2850Hz at 50Hz 4 22 112
Page 79
tyco Fire & Tyco Electronic
Security Product Group
MINERVA Firecryer - Voice Enhanced Sounders
Firecryer
Synchronised and Unsynchronised Variants Standard Messages
Unsynchronised versions provide fast retrofit and AK - “Fire Emergency, Please remain calm and
are acceptable if only one FIRECRYER is used evacuate the building immediately”
per area to enhance the electronic sounders. AB - “This is a fire alert. This is a fire alert. Await
Synchronised variants only require a synchro further instructions. Await further instructions.”
board adding at the fire panel and then allow all
SP - “This is an ADT fire alarm test. No action
FIRECRYERs on two sounder circuits to be
required”
synchronised.
AC - “This is a fire alarm test. No action required.
Low Power
No action required.”
The FIRECRYER takes marginally more power
AD - “All clear. All clear. No further action
than an equivalent electronic sounder. This
required.”
enables voice enhanced sounders to be offered
without the high additional cost of large battery
backups. Sync Board MFC 1SB MFC4SB
The MINERVA FIRECRYER is an electronic Standard Products PCB Dimensions 75.5 x 100mm 138 x 100mm
sounder, which provides as default the same The FIRECRYER is available in 3 models
electronic sound as the MINERVA Besson EMC/RFI CE Marked
(unsynchronised, synchronised and 4 message
Banshees. In addition, the FIRECRYER provides synchronised) in Thorn and ADT branding with Operating Temp -5 to +55°C
up to 4 predefined voice messages, which can be predefined English messages and 100dBA fast Operating Voltage NA 18-30V d.c.
synchronised across a zone of sounders. The sweep alert sound to comply with BS5839Pt1.
FIRECRYER offers an excellent service upgrade Quiescent Current NA 6mA (Max)
Other variants with different branding, different
opportunity in the UK for systems installed to language messages and different tones are Message Mode 28mA
BS5839pt1 and many also provide opportunities available upon request.
elsewhere. Sounder Circuit 2 x 500mA Fused
Technical Specification
Key Features
Dimensions : IP45 - 92dia 61.3 Hmm Product Codes
Single and Four Message Variants
IP66 - 92dia 85.5 Hmm 576.501.037
A single message can confirm that the electronic
Operating Voltage: Nominally 24Vd.c. MFC4DEMO Firecryer 4 message demo box
sound is a fire alarm warning and differentiate it
from other electronic sounders used in an Min. 18Vd.c. Max. 30Vd.c. 576.501.100
environment. With four messages fire tests can be Current Consumption:Average 19mA MFC1SB Firecryer single message synch board
easily differentiated from alert and evacuate Min. 10mA for use with single message synchronised
messages. MINERVA Firecryers
Max.23mA
Two Wire Connection 576.501.101
(Subject to message)
The FIRECRYER uses a standard 2 wire 24V d.c. MFC4SB Firecryer 4 message synch board for
(at max. output)
connection to carry power, message switching and use with 4 message MINERVA Firecryers
message synchronisation. This enables a quick Sound output: Fast sweep - 100dBA
576.501.102
and easy upgrade to existing bells and sounders Voice message: 97dBA approx
MFC1ENC 1 message synch board enclosure for
MINERVA Banshee Compatible Volume Control Via variable resistor with 20dB use with 576.501.100
The electronic alarm sound and mechanics of the range from maximum
576.501.103
FIRECRYER are the same as other Banshee Polarity D.C. reverse polarity protection
MFC4ENC 4 message synch board enclosure
sounders in the range. This allows them to be Operating Temp: -5°C to +55°C with 3 position keyswitch for use with 576.501.101
mixed with other sounders in a zone. It also
Humidity: 90% relative humidity (non- 576.501.042
means that existing Banshees can be very quickly
condensing)
upgraded to FIRECRYERs. An ideal service sale. Banshee IP66 backbox for Loop powered
Weatherproofing: Standard base - IP45 Banshee and Firecryers
Special base - IP66
Housing Material: Red Flame-retardant ABS
Product Codes Product Message Brand Synchronised
Reference 1 2 3 4
576.501.034.A MFC1SEA AK - - - ADT Yes
576.501.034.T MFC1SET AK - - - Thorn Yes
576.501.035.A MFC4SUA AK AB SP AE ADT Yes
576.501.035.T MFC4SET AK AB AC AE Thorn Yes
576.501.036.A MFC1EA AK - - - ADT No
576.501.036.T MFC1ET AK - - - Thorn No
576.501.104.A *MFC4SCA Customer Defined ADT Yes
576.501.104.T *MFC4SCT Customer Defined Thorn Yes
* For recording of special messages there is a charge. This can be ordered under product code
576.501.105 MFC-CM. This includes the supply of a different timer chip for MFC4SB synchronisation
board.
Page 80
tyco Fire & Tyco Electronic
Security Product Group
Visual Indicators
Single Gang Lamp/Buzzer Units
Lamp Buzzer unit used for local alarms when high 540.001.013
level audible warnings may not be appropriate MK2LMP/S Lamp (red)/buzzer unit surface
available in flush and surface mount versions to fit mounting MK2. Labelled ‘Fire’
standard single backboxes
Dimensions: 90H x 90W x 40D mm
Product Codes
540.001.012
Lamp (red)/buzzer unit flush mounting MK2
including single gang backbox. Labelled ‘Fire’
Voltage Power Output Alarm Current Flash Rate Rating Temp. Range Dimensions (mm)
V d.c. Watt(s) mA Height Diameter
24 1 42 60/min IP65 -30 to +70°C 51 75
24 2 84 60/min IP65 -30 to +70°C 51 75
24 3 126 60/min IP65 -30 to +70°C 51 75
24 5 210 60/min IP65 -30 to +70°C 75 90
Page 81
tyco Fire & Tyco Electronic
Security Product Group
Auxiliary Interface Relays
Boxed Relays
568.001.007 568.001.008
Relay 5000 Housing auxiliary relay (small) Relay 5010 Housing auxiliary relay (large)
Page 82
tyco Fire & Tyco Electronic
Security Product Group
Fire Resistant Cable
DÄTWYLER Lifeline cable is suitable for fire tinned drain wire and requires no special The following DÄTWYLER Lifeline cables are held
alarms and emergency lighting where BS6387 terminations, tools or ferrules for installation. in stock at Tyco Electronic Product Group
and BS7629 standards are acceptable and meets Full details of Lifeline cable can be found in the Letchworth, together with suitable P clips and
the installation and performance requirements of: DÄTWYLER Lifeline datasheets on the Tyco glands. Cables are priced per metre but must be
• BS5839 Pt.1 for use in fire alarms Electronic Product Group website ordered in units of 100 metre. P clips and glands
• BS5266 for use with emergency lighting (www.tycofire.com). are priced each but must be ordered in packs.
• BS4066 ‘Tests on electrical cable under fire DÄTWYLER offer a wide range of cable and
conditions’ safety cabling systems including complete safety
• IEC331 fire resistance cable systems to DIN4102 part 12. All
Lifeline is LPCB approved to BS6387 CAT CWZ DÄTWYLER products are available at preferential
and BASEC approved to BS7629. prices to Tyco companies via Tyco Electronic
Lifeline is low smoke, zero halogen, has an Product Group. For more information contact Rob
integral aluminium backed mylar tape screen with Sutcliffe (rsutcliffe@tycoint.com).
No. of Cores x Cross Section (n x mm2) Copper Content (Kg/Km) Total Weight (Kg/Km) Outer Diameter (approx. mm) Calorific Potential (KWh/m)
2 x 1.0 19 75 7.4 0.16
2 x 1.5 29 97 8.2 0.18
2 x 2.5 48 141 9.6 0.24
3 x 1.0 29 92 7.8 0.18
3 x 1.5 43 120 8.6 0.22
3 x 2.5 72 180 10.2 0.30
4 x 1.0 39 114 8.6 0.23
4 x 1.5 58 149 9.6 0.27
4 x 2.5 96 223 11.3 0.37
7 x 1.5 101 230 11.5 0.41
Page 83
tyco Fire & Tyco Electronic
Security Product Group
Water Leak Detection Alarms
Introduction custom made with a variety of types of detection . Electrical Plant and Tank Areas
The Water Leak detection system is a water sensor to suit the characteristics of the areas to be . Valuables, Antiques and Artifacts
detection alarm designed to be used in situations covered. . In general, wherever the presence of water
where not just flooding but also undue dampness This system has been designed for ease of could be a potential problem to people,
could cause damage or ultimately become installation and modern micro-electronics ensure a equipment, perishable stock, data/information
dangerous. high degree of reliability. archives and record stores, hospital theatres
The system comprises an electronic monitoring Typical Applications and so on. There are also sensors for the
and alarm control panel connected to sensors . Computer Rooms, Telecommunications and detection of non-conductive fluids such as
located in the area requiring protection and can be Office Areas diesel/oil.
Compatible Sensors
Sensor Cable, Sensor Pads & Probe Sensors
Product Codes
Sensor Cable
Sensor Pads 516.200.010
CD/5 5 metre length of sensing cable
516.200.011
CD/10 10 metre length of sensing cable
516.200.012
SOL Start of line for sensing cable
516.200.013
EOL End of line for sensing cable
516.200.014
Sensor Cable FF1 Sensing cable fixing clips
516.200.015
CDT Sensing cable identification tags
Sensor Pads
516.200.016
Probe Sensor SFU Sensor pad face up
Sensor Cable Sensor Pads 516.200.006
Sensor cable comprises high flexibility conductors Sensor pads are constructed from glass fibre with SFD Sensor pad face down
insulated by Helagaine mono-filament braiding. an anti-corrosive nickel plated surface. Pads will 516.200.007
Cable or tape sensors are suitable for general detect a few cc’s of liquid and are either face up SFD/C Cover for sensor pad face down
protection under false floors, or can be fastened for location under vulnerable points or face down Probe Sensors
directly to pipework enabling coverage in ceiling for a general coverage. 516.200.004
void areas. Technical Specification SPS/V Vetical mounting probe sensor complete
The cables can be connected together, up to Dimensions: 115H x 160W mm with cover
100m, to cater for larger areas. Probe Sensors 516.200.005
For each zone a ‘start of line’ and an ‘end of line’ Probe sensors are the least sensitive and are Spare Protective cover for probe detector
module is required. often employed as water level sensors. In general
Technical Specification use the sensor is enclosed in a protective cover
Dimensions: 8mm dia which also provides a means for fixing and 20mm
gland entry. The probe is designed for vertical
mounting at skirting level though may be mounted
in voids or sumps. A screw allows 16mm height
adjustment after the sensor is installed.
Technical Specification
Dimensions: 85H x 62W x 62D mm
Page 84
tyco Fire & Tyco Electronic
Security Product Group
Wire Free Fire Product Range
Introduction The Radio Survey Typical Applications
Wire free fire system technology is fast becoming It is important that a radio survey is carried out by . Heritage and Listed Buildings
a recognised and accepted alternative to wired fire trained personnel on all sites, before a complete . Art Galleries and Museums
alarm systems. The Tyco Electronic Product system quotation can be made. Please contact . Schools and Colleges
Group Radio Fire Alarm System provides a level of Tyco Radio Systems at Walthamstow for . Hospitals, Clinics and Nursing Homes
performance and reliability comparable to hard- assistance. . Temporary Systems for Refurbishments
wired systems. It also has the added advantage of . Airports and Military Bases
Features
being totally flexible, quick and easy to install, with . Government and Council Buildings
. Detectors fire tested to prEN 54 Part 7
virtually no damage or disruption. . Exhibition Complexes and Stadia
. Designed to meet BS5839 Part 4
This enables the installation of a fire alarm system
. Unique Carbon Monoxide fire detector
to be carried out in an occupied building where NOTE: The system elements and associated
. Minimum installation damage and disruption
cabling is unacceptable, unwelcome, disruptive or product codes described in the Wire Free section,
. Flexible system design up to 100 zones
impracticable. The cost of “making good” and relate to the UK frequency variants as approved by
. System easily modified or extended
redecorating is significantly reduced with wired the Home Office for use in “low powered” systems
. 80 Character LCD pinpoints each alarm with
systems. in the UK. 173.225 MHz (field devices) and 458
plain text location messages
Radio Systems are highly cost effective and can MHz (battery powered sounders). These
. Full zonal LED display and detailed fault
easily be modified or extended to combine with frequencies may be suitable for applications in
annunciation
existing hard wired systems. A system can be other countries. Please contact Tyco Electronic
. Suitable for permanent or temporary
tailored for use in any existing building to meet Product Group for further information.
applications
highly individual needs for many commercial and
. 200 Event memory
industrial applications. Regarding fire detection,
. Up to 31 repeater panels
the radio system can be considered to be identical
. Long battery life
to a hard-wired system, with the fire survey carried
out to the same standards.
The Radio System
Main Control
KEY
TX Unit
Power AC Supply
Detector
Callpoint
Sounder
Radio Sounder
Repeater Unit
Controllers
LCD. Controls on the unit include Silence, Sound Technical Specification
(Evacuate), Reset, Mute and Test, all of which are Dimensions: 400H x 500W x 185D mm
enabled/disabled through the use of the controller Power Requirements:220/240V, 50Hz
keyswitch. Outputs: 3 x 12Vd.c. monitored relay
The controller monitors the status of the system at outputs up to 1A load
all times. Internal functions on the controller, such 1 x Volt free contact
as battery charge, aerial, and various radio 1 x Clean changeover
functions are monitored and also faults on Product Codes
detectors, the battery condition and tamper are 508.019.001
monitored. TRS Control panel 100 zone
A 100 individual Zone, LED matrix is provided, 508.019.002
together with a separate display to indicate zone TRS Control panel 100 zone plus printer
and device number. Transmit and receive LED’s 509.019.021
The main controller for the Radio Fire Detection also indicate activity on the radio communication TRS Aerial 1m LD20 with bracket
System has been designed to meet BS 5839 link. 3072
Part 4 - 1988. Each unit can support up to 200 There are monitored relay outputs available on the 12V 7Ah Rechargeable battery
direct devices, plus up to 31 repeater panels each controller which can be programmed to operate
with 200 devices. from any zone.
The controller’s 80 character LCD is used to The controller can also support up to 64 battery
display system events in ‘Plain English’ giving powered Radio Sounders (BPS) by fitting an
relevant zone, device and floor numbers for each optional BPS controller card. There is also a
event. Two hundred events are stored in the printer port to allow a printer unit to be
controllers event log which can be viewed from the incorporated into the controller.
Page 85
tyco Fire & Tyco Electronic
Security Product Group
Field Devices
Radio transmitters are incorporated into each field device to communicate with controllers. The units are programmed with a device number, zone number,
system code and RX number and TX number. These identities are sent back to the controller in the event of a fire, battery low condition or tamper, to precisely
identify the location of the event on the controller display.
Power to the radio transmitter is supplied by a two stage Lithium battery pack. The battery pack provides up to five years service under normal operating
conditions. When primary power begins to deteriorate, a signal is sent to the controller and a low battery is indicated. After a ‘battery low’ signal has been
reported, devices will continue to operate for a further three months.
Heat Detectors
The rate of rise/fixed temperature heat detectors Product Codes
can be used in areas where smoke sensors are 516.133.010
unsuitable due to environmental conditions, TRS Lo pro fixed temperature heat detector
(smoke, dust etc.). Such areas include kitchens, 516.134.010
locker rooms, canteens, garages, loading bays TRS Lo pro rate of rise heat detector
etc. 517.130.001
These detectors use two networked thermistors in Radio fire alarm detector base plate
a bridge configuration to provide a fast response
that depends on both absolute temperatures and
notes the change of temperature.
Technical Specification
Dimensions: 110 dia x 76mm
CO Fire Detectors
The CO fire detector is a unique general purpose Technical Specification
fire detector which provides very early warning of Dimensions: 110 dia x 76mm
slow smouldering fires. Ideal for sleeping risks the Product Codes
CO fire detector is also well suited to many 516.132.010
applications where heat detection is insufficient TRS Lo pro CO detector
but smoke detection causes false alarms. 517.130.001
As CO travels more freely than smoke the Radio fire alarm detector base plate
positions of CO fire detectors is more flexible.
This feature is particularly useful in large complex
structures such as atria and warehouses, where
positioning of smoke detectors is difficult. The
MU601 is LPCB Approved.
Callpoints
The Radio Callpoint is designed to enable an Product Code
alarm signal to be generated manually from a 514.006.012
normal break glass callpoint. The alarm signal is TRS Callpoint - 173.225MHz
sent immediately to the controller. An LED on the
callpoint indicates that the device has been
operated.
Technical Specification
Dimensions: 97H x 160W x 70D mm
Page 86
tyco Fire & Tyco Electronic
Security Product Group
Transmitter Units
A universal transmitter is also available to allow
connection to existing fire systems or other inputs,
to transmit fire or fault signals back to the
controller.
Technical Specification
Dimensions: 160H x 70W mm
Product Codes
509.019.051
TRS Transmitter unit
509.019.153
TRS Transmitter unit with external aerial connector
Sounders
Controllers can support both Hard Wired Sounders and Battery Powered Sounders (when BPS controller
card is fitted). Radio Sounders (BPS units) can be specified where wiring is not possible or desirable.
The BPS unit provides sounder activation without the need for an external power source or wiring and
uses a Besson Banshee sounder. The Hard Wired Sounder normally specified is a 12Vd.c. Roshni type.
Product Code
ROSHRDSR
ROSHNI Hard Wired Sounder deep base - red
ROSHRDSR
Radio Sounders
Page 87
tyco Fire & Tyco Electronic
Security Product Group
20 Relay Expander Cards
Relay expander cards may be specified to extend
the relay capacity from the main controller.
Normally only one card can be fitted to the
controller and may be used for connection to
sounders or other devices.
Product Codes
509.019.061
TRS 20 Relay normally open expander card
509.019.077
TRS 20 Relay normally closed expander card
Product Code
509.019.059
TRS 8 Way input expander card
Wirefree Spares
Product Codes
509.019.080
TRS TX/RX PCB & Decoder PCB matched pair
3072
12V 7Ah Rechargeable battery
560.002.031
Battery pack Lithium System 3000
509.019.080 560.002.031
Page 88
APPROVALS LISTING OF COMPANY EQUIPMENT
Thorn Security Limited is registered by British Standards Institution to KRS Korean Register of Shipping.
BS5750 : Part 1 LPCB Loss Prevention Certification Board.
Note: That while every effort is made to keep this document updated, some LRS Lloyds Register of Shipping.
approvals will be renewed and new approvals will be acquired between
MIE Spanish Ministry of Industry and Energy
updates. Any queries, reference approvals, should be made to the Approvals
Engineer [TYCO ELECTRONIC PRODUCT GROUP} Sunbury-on-Thames. MOI Italian Ministry of the Interior.
The approvals obtained for company equipment are listed in Table 1. The MSA Marine Certification Association
approval bodies are identified by the following NACOSS National Approval Council for Security Systems.
abbreviations:- NC Not Coded.
AMSA Australian Maritime Safety Authority. NKK Japanese Register of Shipping.[Nippon Kaiji Kyokai].
ABS American Bureau of Shipping. NMA(S) National Maritime Administration [Sweden, Sjöfartsverket].
BT British Telecom. NMD Norwegian Maritime Directorate [Sjøfartdirektortet].
BASEEFA British Approval Service for Electrical Equipment in Flammable NSI Nederlands Shipping Inspectorate.
Atmospheres. NPTT Dutch Post Office.
BR Brunamalastofnun Rikisins [Iceland Govt. Approval]. NRC Nuclear Regulatory Commission [USA].
BSI British Standards Institute. NRPB National Radiological Protection Board [UK].
BV Bureau Veritas [France]. NSTC China - National Supervisory Test Centre China.
CCG Canadian Coastguard. PRS Polish Register of Shipping.
CCR China Corporation Register of Shipping. PSB Productivity Standards Board of Singapore’s Product Listing
CCS (ZC) China Classification Society. Scheme (PLS)
CIRL Construction Industry Research Laboratory [Australia]. PTB Physikalisch Technisches Bundesanstalt [Germany].
CSA Canadian Standards Association. RA Radiocommunications Authority [DTI]
DDRK DDR Schiffsrevision und Klassifikation [Germany]. RINA Registro Italiano Navale [Italy].
DMA Danish Maritime Authority [Søfartsstyrelsen]. RNR Rumanian Register of Shipping.
DOT Department of Transport [UK] - not used. Now Marine RRS Maritime Register of Shipping [Russia].
Certification Association [MSA]. SAA Standards Association of Australia.
DNV Det Norske Veritas. SSL Scientific Services Laboratory of Australia
DTI Department of Trade and Industry. UL Underwriters’ Laboratories of the United States.
FM Factory Mutual [USA]. ULC Underwriters’ Laboratories of Canada
GL Germanischer Lloyd. USCG United States Coastguard.
HRS Hellenic Register of Shipping VdS Verband der Sachversicherer e.V. [Association of Property
IPTT An Roinn agus Telegrafa [Irish Posts, Telephones and Insurers] (Germany).
Telegraphs].
IR India Radiology. Note: Items in Table 1 with a ‘*’ against the date, indicates that approvals
KM & PA Korean Marine and Port Authority. have been applied for but not yet been received.
TABLE 1: APPROVALS LISTING OF COMPANY EQUIPMENT
Type Description Authority Type Description Authority
601 Intrinsically Safe System [Ex ia] ABS, BASEEFA [82254] H602, H900, Heat Detector ABS, AMSA (H602 & H902), BV
CCS (ZC), PRS, RINA, RNR H901,H902 CCR - (H902 only), CCS (ZC)
NKK DMA - (H602 only)*, DNV, MSA
602 Analogue Addressable BASEEFA [89Y2204], NKK GL - (not H900), KRS, LPCB
Intrinsically Safe System [Ex ia] PRS, RNR LRS, NKK
1700 1-3 Zone Fire LPCB Approved to BS3116 NSTC - (H602/902 only), RRS
Detection System NSTC H604 Heat Detector ABS, BV, CCS (ZC), DNV, GL
1700 4-64 Zone Fire LPCB Approved to BS3116 KRS, LRS, NKK
Detection System NSTC H904 ABS, GL, KRS, LRS, NKK
1700 TNO 4-64 Zone Fire TNO(Netherlands) IF500Ex BASEEFA, BV
Detection System LI520 ABS, BV, CCS (ZC), DMA*
1/2/4 Zone Fire Detection Systems LPCB DNV, MSA, GL*, KRS, LPCB
C2440 Charger BT, RINA LRS, NKK, NMA(S), PRS
CM 520 CCS (ZC), ABS, BV, CCS (ZC) RNR, RRS, USCG
DMA*, DNV, MSA, GL*, KRS LI530Ex BASEEFA
LPCB, LRS, NKK, NMA(S) M300 Detector Base DNV, LRS, KRS, RNR
PRS, RNR, RRS, USCG M300Ex Detector Base [I.S.] BASEEFA, KRS, LRS, RNR
CP 200 Call Point GL, LRS, NKK, RNR, RRS MD301 Gr.1 Rate of Rise ABS, BSI, BV, CCS (ZC), DMA
AMSA, CCS (ZC) Heat Detector DNV, MSA, GL, KRS, LPCB
CP 210, 220, 230, LRS, NKK - (not 270) LRS, NKK, PRS, RNR, RRS
240, 260, 270 AMSA - (230 only) MD301Ex Gr.1 Rate of Rise [I.S.] ABS, BASEEFA, BV, CCS (ZC)
GL - (230 only) Heat Detector DMA, DNV, GL, KRS, LRS
CCS (ZC) - (230 only), RNR NKK, PRS, RNR, RRS
CP 250 LRS, NKK, RRS MD303Ex Gr.3 Rate of Rise [I.S.] BASEEFA, BV
CP 520 ABS, DMA*, MSA, GL*, KRS Heat Detector
LRS, NKK, NMA(S), RNR MD305Ex Temp. Range 2 [I.S.] BASEEFA, BV
RRS, USCG Heat Detector
CP 530 ABS, DMA*, DNV, MSA MF301 Ion Chamber ABS, AMSA, BSI, BV, CCS (ZC)
GL*, KRS, LRS, NKK DMA, DNV, MSA, GL, KRS
NMA(S), RNR, RRS, USCG LPCB, LRS, NKK, NRPB
CP 540Ex BV, DNV, NKK NSTC, PRS, IR, RNR, RRS
CP920 LPCB MF30Ex Ion Chamber [I.S.] ABS, BASEEFA, BV, CCS (ZC)
CP930 LPCB DMA, DNV, GL, KRS, LRS, NKK
DHM35/69 DNV NRPB, PRS, RNR, RRS
DM 520 ABS, BV, CCS (ZC), DMA* MF SERIES (300, 400, 500) NRC
DNV, MSA, GL*, KRS, LPCB MR301 Photo-Optical ABS, AMSA, BSI, BV, CCS (ZC)
LRS, NKK, NMA(S), PRS, RNR Smoke Detector DMA, DNV, MSA, GL, KRS
RRS, USCG LPCB, LRS, MOI, NKK, PRS
H600, H601 Heat Detector ABS, BV, CCS (ZC) RNR, RRS
DMA - (not H600)**, DNV MR301Ex Photo-Optical ABS, BASEEFA, BV, CCS (ZC)
MSA, GL - (not H600), KRS Smoke Detector [I.S.] DMA, DNV, GL, KRS, LRS, NKK
LPCB, LRS, NKK, RRS PRS, RNR, RRS
MR301T High Performance Optical LPCB
Smoke Detector [I.S.]
Page 89
APPROVALS LISTING OF COMPANY EQUIPMENT
Type Description Authority Type Description Authority
MR301TEx High Performance Optical BASEEFA Relay 5000 BT
Smoke Detector [I.S.] Relay 5010 BT
MS302Ex I.R. Flame Detector [I.S.] ABS, AMSA, BASEEFA, BV S111, S112 IR Flame Detector ABS, BASEEFA [812333], BV*
CCS (ZC), DMA, DNV, MSA CCS (ZC), DMA*, MSA, KRS
GL, KRS LPCB, LRS, PRS, RRS, SAA
M500 Detector Base ABS, DMA*, DNV, MSA, KRS VdS
LRS, RNR, USCG S121 IR Flame Detector ABS, BASEEFA [812333], BV*
M500Ex Intrinsically Safe Detector Base ABS, LPCB, BV, DNV, KRS CCS (ZC), CSA, DMA*, MSA
LRS, RNR, USCG KRS, LPCB, LRS, SAA, VdS
MD501 Analogue Addressable ABS, BV, CCG, CCS (ZC) S122 IR Flame Detector ABS, BASEEFA [812333]
Heat Sensor DMA*, DNV, MSA, GL, KRS BV*, CCS (ZC), DMA*, MSA
LPCB, LRS, NKK, NMA(S) KRS, LRS, SAA
PRS, RNR, RRS, USCG S131 IR Flame Detector ABS, BASEEFA [812333], DNV
MD501Ex Intrinsically Safe Analogue ABS, BASEEFA, BV, CCS (ZC) MSAPRS, LRS, NSTC, SAA
Addressable Heat Sensor DNV, GL, KRS, LRS, NKK VdS
PRS, RNR, RRS, USCG S161 I.R. Flame Detector BASEEFA [87Y3550], DNV
MF501 Analogue Addressable Ion ABS, AMSA, BV, CCG, MSA, LPCB, LRS
Chamber Sensor CCS (ZC), DMA*, DNV, MSA S231f+ I.R. Flame Detector (Flameproof) DMA, BASEEFA [EX94C1388]
GL, KRS, LPCB, LRS, NKK LPCB (pending), DNV (pending)
NMA(S), NRPB, NSTC, PRS
RNR, RRS, USCG LRS (pending)
MF501Ex Analogue Addressable Ion ABS, BASEEFA, BV, CCS (ZC) S232f+ I.R. Flame Detector (Flameproof) DMA, BASEEFA [EX94C1388]
Chamber Sensor [I.S.] DNV, GL, KRS, LRS, NKK S231i+ I.R. Flame Detector (I.S.) DMA, BASEEFA [EX94C2080]
NRPB, PRS, RNR, RRS, USCG LPCB (pending), DNV (pending)
MR501 Analogue Addressable ABS, BV, CCG, CCS (ZC) LRS (pending)
Optical Sensor DMA*, DNV, MSA, GL, KRS S241f+ I.R. Flame Detector (Flameproof) DMA, BASEEFA [EX94C1388]
LPCB, LRS, NKK, NMA(S), PRS LPCB (pending), DNV (pending)
RNR, RRS, USCG LRS (pending)
MR501Ex Analogue Addressable ABS, BASEEFA, BV, CCS (ZC) S241i+ I.R. Flame Detector (I.S.) DMA, BASEEFA [EX94C2080]
Optical Sensor [I.S.] DNV, GL, KRS, LRS, NKK, PRS LPCB (pending), DNV (pending)
RNR, RRS, USCG LRS (pending)
MR501T Analogue Addressable High LPCB S251f+ I.R. Flame Detector (Flameproof) DMA, BASEEFA [EX94C1388]
Performance Optical Sensor LPCB (pending), DNV (pending)
MR501TEx Analogue Addressable High BASEEFA LRS (pending)
Performance Optical Sensor [I.S.] S252f+ I.R. Flame Detector (Flameproof) DMA, BASEEFA [EX94C1388]
MS502Ex Analogue Addressable ABS, AMSA, BASEEFA, BV FM
Infra Red Sensor [I.S.] CCG, CCS (ZC), DNV, NMA(S) S251i+ I.R. Flame Detector (I.S.) DMA, BASEEFA [EX94C2080]
KRS S261f+ I.R. Flame Detector (Flameproof) DMA, BASEEFA [EX94C1388]
MD601 Gr. 1 Rate of Rise Heat Detector LPCB, MIE LPCB (pending), DNV (pending)
MD611 Gr. 2 Fixed Temp. Heat Detector LPCB, MIE LRS (pending)
612H Heat detector 135 ° F Fixed/ R-of-R UL, ULC S262f+ I.R. Flame Detector (Flameproof) DMA, BASEEFA [EX94C1388]
622H Heat detector 135 ° F Fixed UL, ULC FM
632H Heat detector 200 ° F Fixed UL, ULC SB520 Sounder Booster Module ABS, BV, CCS (ZC), DMA*
MD613 Gr. 1 Rate of Rise Heat Detector VdS MSA, GL, KRS, LPCB, LRS
MD623 Gr. 2 Static Heat Detector VdS NKK, NMA(S), PRS, RNR
MF601 Ion Chamber Detector NRPB, LPCB, NSTC RRS, USCG
MF601M Ion Chamber Detector ABS, BV, DNV, GL, KRS SM520 Sounder Module ABS, BV, CCS (ZC), DMA*
MSA, LRS, NKK, PRS MSA, GL, KRS, LPCB, LRS
612I Ionisation Smoke Detector UL NKK, NMA(S), PRS, RNR
MF613 Ion Chamber Detector VdS RRS, USCG
MR601 Optical Smoke Detector LPCB, LRS, MIE T1000 Marine Controllers ABS, BV, CCS, DNV, GL, NKK
MR601M Optical Smoke Detector ABS, BVD, NV, GL, KRS KRS, LRS, RINA, RRS
MSA, NKK, PRS T110 I.R. Test Source BASEEFA [Ex84B2224]
612P Photoelectronic Smoke Detector UL, ULC, FM (pending) T210 I.R. Test Source BASEEFA [Ex84B2224]
MR613 Optical Smoke Detector VdS T280 Repeater Unit ABS, AMSA, BV, CCS (ZC)
MR601T High Performance Optical Smoke LPCB, MIE CCR, DMA*, MSA, GL, KRS
Detector LRS, NKK, PRS, RINA, RNR
612HP High Performance Optical Smoke NEDG, UL, ULC, FM (pending) RRS
Detector T281 Repeater Unit ABS, BV, CCS (ZC), DMA*
MR613T High Performance Optical Smoke VdS MSA, GL, KRS, LRS, PRS
Detector RINA, RNR, RRS, NKK
MD901 Analogue Addressable Heat LPCB, NSTC, MIE T290 Repeater Unit ABS, BV, CCS (ZC), CCG
Sensor [Minerva Marine] DMA*, MSA, GL, KRS, LRS
912H Heat Detector Head UL, ULC, FM (pending) NKK, NMA(S), RINA, RNR
MF901 Analogue Addressable Ion LPCB, NSTC RRS, USCG
Chamber Detector T291 Repeater Unit ABS, BV, CCS (ZC), CCG
MF901M Analogue Addressable Ion ABS, BV, DNV, GL, KRS, MSA [Minerva Marine] DMA*, DNV, MSA, GL*, KRS
Chamber Detector LRS, NKK, PRS LRS, NKK, NMA(S), RINA
912I Ionisation Detector Head UL, ULC, FM (pending) RNR, RRS, USCG
MR901 Analogue Addressable Optical LPCB, LRS, MIE T680 Power Unit ABS, BV, CCS (ZC), CCR, DNV
Smoke Sensor MSA, GL, KRS, LRS, NKK
MR901M Analogue Addressable Optical ABS, BV, DNV, GL, KRS, MSA PRS, RINA, RNR, RRS
Smoke Sensor NKK, PRS T880 32-Zone Fire Controller ABS, BV, CCS (ZC), CCR
912P Photoelectronic Detector Head UL, ULC, FM (pending) DMA*, DNV, MSA, GL, KRS
MR901T Analogue Addressable High LPCB, NSTC, MIE LRS, NKK, PRS, RINA, RNR
Performance Optical Sensor RRS
912HP High Performance Photoelectronic UL, FM (pending) T881 8-Zone Fire Controller ABS, AMSA, BV, CCS (ZC)
Smoke Detector Head CCR, DNV, MSA, GL, KRS
MINERVA 8 PSB LRS, NKK, PRS, RINA, RNR
MINERVA 16 LPCB, NSTC RRS
MINERVA 16R LPCB, NSTC T882 4-Zone Fire Controller ABS, BV, CCS (ZC), CCR, DNV
MINERVA 16E LPCB, NSTC, PSB MSA, GL, KRS, LRS, NKK, PRS
MINERVA 80 LPCB, NSTC, PSB RINA, RNR, RRS
MINERVA 80R LPCB, NSTC T890 80-Zone Fire Controller ABS, AMSA, BV, CCS (ZC)
MTL Intrinsically Safe Systems CSA, BASEEFA [Minerva Marine] CCG, DNV, MSA, GL*, KRS
Equipment LRS, NKK, NMA(S), PRS, RINA
NT100 8 and 16 Zone Controllers ABS, BV, DNV, FAB, GL, LPCB RNR, RRS, USCG
ANPI/BOSEC (pending), LRS T891 16-Zone Fire Controller ABS, BV, CCS (ZC), CCG
AB (Sweden) [Minerva Marine] 2.96 2.2000 DMA*, DNV, MSA, GL*, KRS
NTR08/NTR16 Releasing Panels ANPI/BOSEC (pending) NKK, NMA(S), PRS, RNR, RINA
RM520 ABS, AMSA, BV, CCS (ZC) RRS, USCG
DMA*, DNV, MSA, GL, KRS ThornNet LPCB
LPCB, LRS, NKK, NMA(S) TLK530 LPCB
PRS, RRS, USCG
Page 90
tyco Fire & Tyco Electronic
Security Product Group
Standard AutoCAD Symbols
Tyco Electronic Product Group now has an IntraNet Products and also Diagrams for many Tyco Electronic If you require any further information on this or other
site devoted to users of AutoCAD Design Packages Product Group products supplied from the UK, this will aspects of CAD development please contact Lisa
for electronic and electrical systems. be expanded to include all Tyco Electronic Product Thomson on Tel: +44 (0) 1932 743321, Fax: +44 (0)
The site has been set up with a view to utilising a Group products. 1932 743330 or e-mail: lthomson@tycoint.com or
common approach to AutoCAD output for drawing Please encourage your CAD operators to visit this alternatively visit our website at www.tycofire.com
offices using Tyco Electronic Product Group products website. Even if you're business does not use all
and systems. these products many of the symbols, schematics and
Initially this site includes Standard Symbols for Tyco drawings may be adapted quickly and easily for other
MX Technology & MX-Graph, Fire, CCTV and Access products.
Page 91
tyco Fire & Tyco Electronic
Security Product Group
Symbol Name Symbol Name Symbol Name Symbol Name
FPAC4.dwg FPAC5.dwg FPANEL.dwg FPM.dwg
CONVENTIONAL CONVENTIONAL HORN CONVENTIONAL PANEL CONVENTIONAL PLANT
CEILING MOUNTED MODULE
SPEAKER