Professional Documents
Culture Documents
1
1. Range and Span:
v The range of a transducer defines the limits between which the input can vary.
v The difference between the limits (maximum value - minimum value) is
known as span.
v For example a load cell is used to measure force. An input force can vary from
20 to 100 N. Then the range of load cell is 20 to 100 N. And the span of load
cell is 80 N (i.e., 100-20)
2. Error:
v If the transducer is ideally designed and made from appropriate materials with
ideal workmanship, then output will indicate the true value. But in actual
practice the output of the transducer will deviate from the true value.
v The algebraic difference between the indicated value and the true value of the
measured parameter is termed as the error of the device.
v Error = Indicated value —true value
v For example, if the transducer gives a temperature reading of 30°C when the
actual temperature is 29° C, then the error is + 1°C. If the actual temperature is
3 1° C, then the error is —1°C.
3. Accuracy:
v Accuracy is the extent to which the value indicated by the measurement
system would be wrong.
v Accuracy is the summation of all possible errors that are likely to occur.
v For example, a thermocouple has an accuracy of ± 1° C. This means that
reading given by the thermocouple can be expected to lie within + 1°C (or) —
1°C of the true value.
v Accuracy is also expressed as a percentage of the full range output (or) full-
scale deflection.
v For example, a thermocouple can be specified as having an accuracy of ±4 %
of full range output. Hence if the range of the thermocouple is 0 to 200°C,
then the reading given can be expected to be within + 8°C (or) —8° C of the
true reading.
4. Sensitivity:
v The sensitivity is the relationship showing how much output we can get per
unit input.
v ie sensitivity = Output / Input
5. Hysteresis error:
v When a device is used to measure any parameter plot the graph of output Vs
value of measured quantity.
v First for increasing values of the measured quantity and then for decreasing
values of the measured quantity.
v The two output readings obtained usually differ from each other.
2
Fig.1.1 Hysteresis error
6. Non-linearIty error:
v A linear relationship is assumed between the input and output and hence, a
straight line is drawn in the graph as shown here.
Fig.1.2
v Some transducers, do not have linear relationship and errors occur as a result
of the assumption of linearity.
v The error is defined as the maximum difference from the straight line.
v There are three methods to find the the numerical error. They are namely,
(i) End range value
(ii) Best straight line for all values
(iii) Best straight line, through zero point.
v In the first method, (fig 1.2), the straight line is drawn by joining the output
values at the end points of the range.
3
v In the next method, the straight line is drawn by using the method of least
squares to determine the best fit line by considering all data values are in error.
Refer fig (1.3).
v In the last method, the straight line is drawn by using the method of least
squares to determine the best fit line which passes through the zero point.
Fig.1.3 Fig.1.4
7. Repeatability/Reproducibility:
v The repeatability and reproducibility of a transducer are its ability to give the
same output for repeated applications of the same input value.
v Repeatability is also defined as the measure of the deviation of test results
mean value.
8. Reliability:
v The reliability of a system is defined as the possibility that it will perform its
assigned functions for a specific period of time under given conditions.
v The reliability of a device (or) system is affected not only by the choice of
individual parts in system but also by manufacturing methods, quality of
maintenance and the type of user.
9. Stability:
v The stability of a transducer is its ability to give the same output when used to
measure a constant input over a period of time.
v The term drift is the change in output that occurs over time.
v The drift can be expressed as a percentage of the full range.
v Zero drift means if there is change in output when there is zero input.
10. Dead band / time:
v There will be no output for certain range of input values. This is known as
dead band. There will be no output until the input has reached a particular
value.
v The length of time from the application of an input until the output begins to
respond and change is known as Dead time.
4
11. Resolution:
v Resolution is defined as the smallest increment in the measured value that can
be detected.
v The resolution is the smallest change in the input value which will produce an
observable change in the input.
v Resolution is also known as the degree of fineness with which measurements
can be made.
v For example, if a micrometer with a minimum graduation of 1mm is. used to
measure to the nearest 0.5 mm, then by interpolation, the resolution is
estimated as 0.5 mm.
12. Backlash:
v Backlash is defined as the maximum distance (or) angle through which any
part of a mechanical system can be moved in one direction without causing
any motion of the attached part.
v Backlash is an undesirable phenomenon and is important in the precision
design of gear trains.
13. Output Impedance:
v Before defining impedance, we should know about Ohm’ s law.
v Ohm’ s law is used to define the relationship between voltage V, Current I and
Resistance R.
(i.e.,) V=IR
v Ohm’ s law can be extended to the AC circuit analysis of resistor, capacitor
and inductor elements as
v=ZI
where Z is called impedance of the elements. So impedance is similar to
resistance.
v The sensors produce electrical output.
v When these sensors are interfaced with an electronic circuit, it is necessary to
know the output impedance.
v This impedance is connected in either series (or) parallel with that circuit and
the inclusion of the sensor will modi1 the behaviour of the system to which it
is connected.
Displacement Sensors:
The measurement of the amount by which some object has been moved.
1. Potentiometer,
2. Resistance strain gauge,
3. LVDT,
4. Push pull displacement sensor.
5
Position Sensors:
v The determination of the position of some object with reference to some
reference point.
1. Photo electric sensors,
2. H sensors.
Proximity Sensors:
v Used to determine when an object has moved to within some particular critical
distance.
1. Pneumatic proximity sensor,
2. Eddy current proximity sensor,
3. Inductive proximity switch,
4. Micro switch,
5. Reed switch.
1. Contact Sensors:
2. Non-contact sensors:
v The measured object is no physical contact between the measured object and
the sensor.
v In the non-contact sensors the measured object causing a change in the air
pressure in the sensor, or a change in inductance or capacitance.
6
1. Potentiometer Sensor
Fig.1.5
Fig.1.6
7
Fig.1.7
8
3. Semiconductors strain gauges.
Fig.1.8
Fig.1.9
9
v In Metal Wire Strain Gauges a wire stretched between two points in an
insulating medium such as air.
v The wires may be made of various copper nickel, chrome nickel or nickel iron
alloys. They are about 0.003 mm in diameter and gauge factor of 2. The length
of wire is 25 mm or less.
v In Metal foil strain gauge the foil is usually made up of constantan, and it is
etched in a grid pattern onto a thin plastic backing material, usually polyimide.
The foil is terminated at both ends with large metallic pads.
v The size of the entire gauge is very small and has a length of 5 mm to 15 mm
length.
v In Semiconductor strain gauges the p type and n type silicon semiconductors
are used.
v The semiconductor strain gauges have the gauge factors of about +100 or —
100. In p-type gauges resistance increases with tensile strain. While in n-type,
resistance decreases. Typical thickness is about 0.25 mm and effective length
range from 1.25 to 12 mm.
Fig.1.10
Fig.1.11
10
v It consists of three coils symmetrically spaced along an insulated tube.
v The central coil is primary and other two are secondary.
v A magnetic core is moved through the central tube, so that the displacement
being monitored.
v When voltage is supplied to the primary coil, alternating e.m.f.s are induced in
the secondary coils.
v Suppose the magnetic core is in central, the e.rn.f. induced in each coil is same
because of magnetic material in each coil is same and oppose to each other. So
there is no output.
v If the core is displaced from the central position there is a greater amount of
magnetic core in one coil than the other. This will create a higher e.m.f. in one
coil and lesser e.m.f. in the other coil. This will make a net difference in two
e.m.f.s and the displacement being monitored.
v The formulas which are used in LVDT are:
1. The e.m.f.s induced in the two secondary coils 1 and 2 are:
where K1, K2 are degree of coupling between the primary and secondary
coils.
Advantages of L VDT:
1. High range
2. Friction and electrical isolation
3. Low hysteresis
4. Power consumption is less.
v It has three plates with the upper pair forming one capacitor and the lower pair
forming another capacitor.
v There is a non-linear relationship form between the change in capacitance AC
and the displacement X.
v The displacement moves the central plate between the two other plates.
v The result of this, the central plate moving downwards and to increase the
plate separation of the upper capacitor and decrease the separation of the lower
capacitor.
11
C2 is in an other arm of an a.c. bridge.
= Relative permittivity of the dielectric between the
= Permittivity of free space constant,
x = Displacement,
A = The area of overlap between the two plates,
d = The plate separation.
1. Photoelectric Sensors
v It is used to detect the object by breaking a beam of light (Refer Fig.1.12(a))
or radiation falling on a device or by detecting the light reflected back by the
object (Refer Fig.1.12(b)).
Fig.1.12
v Hall effect: Hall effect is defined as when a beam of charged particles passes
through magnetic field, the beam is deflected from its straight line path due to
the forces acting on the particles.
v A current flowing in a conductor like a beam is deflected by a magnetic field.
Fig.1.13
12
v The difference of potential is produced between the opposite edges of the
conductor. The magnitude of the voltage depends upon the current and
magnetic field.
v In the Fig. the current is passed through leads 1 and 2 of the strip. The output
leads connected with Hall strip.
v When a transverse magnetic field passes through the strip the voltage
difference occur in the output leads.
v The hail effect sensor have the advantages of being able to operate as switches
and it operate upto 100 KHz.
Fig.1.14
1. Absolute Encoder:
13
Fig. 1.15. Components of an optical encoder
Fig. 1.16 4-bit gray code absolute encoder disk track patterns
2. Incremental Encoder:
v Working: A beam of light passes through the slots in a disc and it is detected
by a suitable light sensor.
v When the disc is rotated, the output is shown in terms of pulses and these
pulses being proportional to the angle of disc rotation.
14
Fig. 1.17. Incremental encoder
15
v If there is a close by object means the air will not escape readily, so the
pressure increases in the sensor output port. This output from the sensor
depends on the proximity of objects.
v The above Fig. shows the basic form of such sensor and it is used for the
detection of non-magnetic conductive materials.
4. Microswitch:
v It is used for determining the presence of an item on a conveyor belt and this
might be actuated by the weight of the item on the belt depressing the belt by a
spring loaded platform nearer to the sensor the presence of item in the
conveyor is determined.
v The closeness of switch is done by movement of this spring loaded platform.
5. Reed switch:
v It is a non-contact proximity switch. It is used for checking the closure of
doors.
v It consists of two magnetic switch contacts sealed in a glass tube.
16
Fig. 1.21. Reed switch
v When a magnet is brought close to the switch, the magnetic reeds are attracted
each other and close the switch contacts.
To detect and monitor the velocity and motion the following sensors are used.
v In moving magnet type the sensing element is a rod that is rigidly coupled to
the device whose velocity is being measured.
v This rod is a permanent magnet. This permanent magnet is surrounded by a
coil.
v The motion of the magnet induces a voltage in the coil and the amplitude of
the voltage is directly proportional to the velocity.
17
2. Moving coil type velocity transducer:
3. Tachogenerators:
v A sensor that converts speed of rotation directly into electrical signal is called
a tachogenerator.
v It is used to convert angular speed into a directly dependent voltage signal.
(a) Toothed Rotor Variable Reluctance Tachogenerator:
v It is used to measure angular velocity.
v This tachogenerator consists of a metallic toothed rotor mounted on the shaft
whose speed is to be measured.
v A magnetic pick up is placed near the toothed rotor and this magnetic pick up
consists of a housing, and the housing containing a small permanent magnet
with a coil wound around it.
v When the rotor rotates, the reluctance of the air gap between pickup and the
toothed rotor changes and the rise in e.m.f. is induced in the pickup coil.
Finally the output is in the form of pulses and wave shapes.
v The pulses induced depend upon the number of teeth in the rotor and the
rotational speed. When the speed is known, the rotational speed is calculated
by measuring the frequency pulses.
18
v
v Suppose the rotor has ‘ n’ teeth and the speed of rotation is ‘ N’ r.p.s. and
number of pulses per second is ‘ p’ .
19
4.2 MOTION SENSORS
1. Stroboscope:
v Stroboscope is a simple portable manually operated device for periodic or
rotary motions measurement.
v It is a variable frequency flashing light instrument and the flashing is set by
the operator.
v If a strong light is caused to flash on a moving object at the time each flash
occurs. The stroboscope occupies a given position, and the object will appear
to be stationary.
v The flashing light whose frequency can be varied and controlled, and this
source is called strobotron.
2 Pyroelectric Sensors:
v It consists of a polarised pyroelectric crystal with thin metal film electrodes on
opposite faces. (Pyro electric materials, e.g., lithium tantalate are crystalline
materials which generate charge in response to heat flow. When such materials
heated to about 610°C in an electric field, the electric dipoles within the
material line up and it becomes polarised as shown in Fig.).
v Due to the crystal is polarised with charged surfaces, the ions are drawn from
the surrounding air and electrons from any measurement circuit is connected
to the sensor to balance the surface charge as shown in Fig.
v For measurement of a human or heat source motion, the sensing element has
to differentiate between general background heat radiation and a moving heat
source. For that a single pyroelectric sensor is not capable to use and dual
pyroelectric sensors are used as shown in Fig.
v In this dual pyroelectric sensors the sensing element has the one front
electrode and two back electrodes. When two sensors being connected means
both sensors are receive the same heat signal and their outputs are cancelled.
20
v Suppose a heat source moves from its position means the heat radiation moves
from one of the sensing elements to the other, then the current is alternates in
one direction first and then reversed to the other direction second.
v A moving human gives an alternating current of 1O A. When the infrared
radiation is incident on the dual pyroelectric sensor material and changes its
temperature, the polarisation in the crystal is reduced. A focusing device is
needed to direct the infrared radiation onto the sensor.
1. Diaphragms
v In this the pressure to be measured is applied to the diaphragm, causing it to
deflect, and the deflection being proportional to the applied pressure. This
movement can be monitored by some form of displacement sensor. (Example
for displacement sensor is strain gauge) and it is shown in Fig.2.27.
21
Fig. 2.28. Diaphragm type strain gauge pressure transducer
v A specially designed strain gauge is also used for measuring pressure and it
consisting of four strain gauges with, two measuring the strain in a
circumferential direction while remaining two measure strain in a radial
direction. The four strain gauges are connected to form the arms of a
wheatstone bridge a shown in Fig.2.28.
v The deflection at any point is shown in terms of +ve and —ye sign. The stress
distribution on the diaphragm surface is almost ideal for practical purposes,
since both compressive and tensile stresses exit. So this will allow the use of a
four arm wheatstone bridge where all the gauges are active and consequently
there is a large output.
v The strain gauges I and 4 are placed at close to the centre and oriented to read
tangential strain and its value is +ve maximum at this point.
v The gauges 2 and 3 are oriented to read radial strain and it is placed close to
the edge as possible.
2. Bellows
v A metallic bellows is a series of circular parts as shown in Fig.2.29 and the
parts are formed or joined in such a manner that they are expanded or
contracted axially by change in pressure.
22
v The Fig.2.30 shows the bellows can be combined with a LVDT to give a
pressure sensor with an electrical output.
v The bellows are made up of materials like stainless steel, phosphor bronze,
nickel, rubber and nylon.
v The output pressure is calibrated through the LVDT.
3. Capsule
v Capsules are one of the pressure measuring device and it can be considered to
be just two corrugated diaphragms combined and give even greater sensitivity.
v The capsules are more sensitive in measuring pressure.
5. Tactile Sensor
v It is one form of pressure sensor and it is used to determine the pressure in
Robotics in such a form fingertips of robotics contact with the object.
23
v These type of sensors also used in ‘ touch display screens’ where physical
contacts to be sensed.
v The above Fig.2.33 shows the one form of tactile sensor.
v It uses piezo electric polyvinylidene fluoride (PVDF) film.
v There are two layers of such film is used and it is separated by a soft film
which transmits vibrations.
v The alternating voltage is supplied in the lower PVDF film and this results in
mechanical oscillations of the film.
v The intermediate film transmits these vibrations to the upper PVDF film.
v Due to the piezoelectric effect the vibrations formed are cause an alternating
voltage to be produced across the upper film.
v So the pressure is applied to the upper PVDF film and its vibrations are
affected the output voltage.
6. Piezoelectric sensor
24
1. Turbine Flowmeter
v The Fig.2.35 shows the turbine flowmeter and it consists of a multi-bladed
rotor which is supported in the pipe along with the flow occurs.
v The rotor rotation depends upon the fluid flow and the angular velocity is
proportional to the flow rate.
v The rotor rotation is determined y the magnetic pick-up, which is connected to
the coil.
v The revolution of the rotor is determined by counting the number of pulses
produced in the magnetic pick up. The accuracy of this instrument is ± 3%.
Fig. 2.35.
2. Orifice Plate
v It is a simple disc with a central hole and it is placed in the tube through which
the fluid flow.
v From the above Fig.2.36 the pressure difference measured between a point
equal to the diameter of the tube upstream and half the diameter of down
stream.
v The accuracy of this instrument is ±1.5%.
25
1. Differential Pressure Sensor
v In this the differential pressure cell determines the pressure difference between
base of the liquid and atmospheric pressure.
v The differential pressure sensor can be used in either form of open or closed
vessel system.
Fig. 2.37.
2. Float System
v In this method the level of liquid is measured by movement of a float.
v The movement of float rotates the arm and slider will move across a
potentiometer.
v The output result is related to the height of the liquid.
Fig. 2.38.
26
v
v There are three e.m.f.s present in a thermoelectric circuit. In this the Seebeck
e.m.f. is caused by the junction of dissimilar metals and the Pettier e.m.f. is
caused by a current flow in the circuit, and the Thomson e.m.f. which results
from a temperature gradient in the materials.
v It is observed that all thermocouple circuits must involve at least two
junctions. In that one of the junctions senses the desired or unknown
temperature.
v This junction is called the hot or measuring junction. The other junction is
usually maintained at a known fixed temperature and this junction is called the
cold or reference junction.
v If the temperature of the reference or cold junction is known, the temperature
of the hot or the measuring junction can be calculated by using the
thermoelectric properties of the materials.
v If thermocouple circuit can have other metals in the circuit and they will have
no effect on the thermoelectric e.m.f.
v A thermocouple can be used with the reference junction at a temperature other
than
v 0°C.
v For that we assume a 0°C junction and the correction has to be applied using
the law of intermediate temperatures.
27
v Here to maintain the 0°C at one junction a compensation circuit is Used to
provide an e.m.f. which varies with the temperature of the cold junction.
v When it is added to the thermocouple e.m.f. it will generate a combined e.m.f.
This is shown in Fig.2.42.
v In the above Fig.2.42, the wires from the measuring junction are screwed
directly to an isothermal block terminal strip.
v The temperature of the block is ambient temperature.
v This reference temperature is measured by semiconductor sensor and
compensation circuitry develops a voltage Ecomp which is combined with
measuring junction and the net voltage across the voltmeter = T (Temperature
being measured).
v The isothermal block can accept many thermocouple pairs in multichannel
instruments with microprocessor computing power since the T (reference
junction sensor now sends its temperature data to the computer which
computes the needed voltage correction for each thermocouple.
v The thermocouples like E, J, K and T are relatively cheap and it has accuracies
of about ± ito 3%.
v The noble metal thermocouples are very high cost compared with this and it
has accuracies of about ±1% better than the base metal thermocouples.
v Thermocouples are used in applications ranging from measurement of room
air temperature to that of a liquid metal bath. The problems which may be
encountered are
1. Faulty reference junction,
2. Installation faults,
3. Junctions formed by users may involve excessive temperatures or faulty
soldering techniques,
4. Gross errors can result due to wrong installation of thermocouple.
2. Resistance Temperature Detectors (RTDs)
28
v
Fig. 2.43. Resistance temperature detector
v The Resistance temperature detectors are simple, and resistive elements in the
form of coils of wire and it is shown in the above Fig.2.44.
v The equation which is used to find the linear relationship in RTD is
Fig. 2.45.
29
Salient Features ofRTDs:
1. High degree of accuracy.
2. Resistance thermometer is interchangeable in a process without compensation or
recalibration.
3. It is normally designed for fast response as well as accuracy to provide close
control of processes.
3. Thermistors
v Thermistor is a semiconductor device that has a negative temperature
coefficient of resistance in contrast to positive coefficient displayed by most
metals.
v Thermistors are small pieces of material made from mixtures of metal oxides,
such as Iron, cobalt, chromium, Nickel, and Manganese.
v The shape of the materials is in terms of discs, beads and rods.
v The thermistor is an extremely sensitive device because its resistance changes
rapidly with temperature.
v The resistance of conventional metal-oxide thermistors decreases in a very
non-linear manner with an increase in temperature is shown in the Fig.2.46
below.
v The change in resistance per degree change in temperature is considerably
larger than that which occurs with metals.
30
4. Thermodiodes and Transistors
(a) Thermodiodes:
v Thermodiode is widely used method for measuring temperature. When the
temperature of doped semiconductors changes, the mobility of their charge
carriers changes and this affects the rate at which electrons and holes can
diffuse across ap-n junction.
1. Measurement of temperature,
2. Control of temperature,
3. Temperature compensation,
4. Measurement of thermal conductivity,
5. Measurement of power at high frequencies,
6. Measurement of composition of gases,
7. Providing time delay,
8. Vacuum measurements.
v The difference in voltage and current through the junction is a function of the
temperature. The equation which is used to find the I is
31
5. Bimetallic strips
Fig. 2.50.
32
v If the diode is sufficiently reverse biased, it will breakdown.
v The current passing through the diode when forward biased only.
v If an A.C. voltage is applied across a diode, it can be regarded as only
switching on when forward bias it and being off in the reverse direction.
v The photodiodes have a very fast response to light and it can be used as a
variable resistance device controlled by the light incident on it.
2. Photo Transistors
Fig. 2.51.
v The main current flows in at the collector and out at the emitter in npn
transistor.
v The main current flowing in at the emitter and out at the collector in pnp
transistor.
v The phototransistors have a light sensitive collector-base p-n junction.
v There is a very small collector to emitter current when there is no incident
light. Suppose the light is incident a base current is produced and it is
proportional to the light intensity.
v So this will produce a collector current and it is used for measure of the light
intensity.
v The example for photo transistors is photo Darlington arrangement.
33
8.0 SELECTION OF SENSORS
PART- A
34
24. What is a comparator?
25. Name an application of a Schmitt trigger.
26. Why integrators are preferred over differentiators in analog computers?
27. What is a voltage follower?
28. What is the advantage of CMOS Schmitt trigger?
PART-B
1. Explain the terminologies used in transducers.
2. What are all the displacement sensors? Explain each one briefly.
3. Explain the position sensors with neat figure.
4. Define proximity and explain the proximity sensors.
5. What are all the velocity and Motion sensors?
6. How the pressure is measured? Explain the pressure sensors neatly.
7. Explain the temperature measurement sensors.
8. Explain the light sensors with neat figure.
9. What are all the points to be considered while selecting the sensors?
10. Explain the signal processing.
11. Explain some applications of operational amplifier.
12. Explain the operation of successive approximation ADC.
13. How do a dual slope ADC and single slope ADC differ?
14. What is Flash ADC ? Discuss.
15. Explain the construction of R-DR ladder DAC.
16. Discuss the various terms associated with ADC.
35