CUSTOMER xxxxxxxxx PLANT LOCATION xxxxxxxxxx PROJECT / UNIT xxxxxxxxxxxx RATING INPUT

JOB

UNIT

xxxxxxxxx
ITEM

xxxxx

Sh.

of

Rev.

GAS PROPERTIES Mass Flow Rate kg/h Density kg/m3 Viscosity cp Adiabatic Coeff. cp/cv / Compressibility Factor / Z Molecular Weight kg/kmol

71740.0 9.08 0.0094 1.162 0.9309 44.65

Separator Type Inlet Distributor Type Demister (See Note 1) Head Type

Other Half Open Pipe

Yes Elliptical 2:1

LIGHT LIQUID PHASE PROPERTIES Mass Flow Rate kg/h 35410.0 Density 602.30 kg/m3 Viscosity cp 0.1896

OPERATING CONDITIONS Temperature C Pressure (gauge) barg NOZZLES NIN Inlet NG Gas Outlet NLl Light Liquid Outlet NLh Heavy Liquid Outlet Manhole

32.22 4.80

HEAVY LIQUID PHASE PROPERTIES Mass Flow Rate kg/h 5361.0 Density 1002.00 kg/m3 Viscosity cp 0.7606

in in in in in

24 14 6 2 24

VESSEL SIZING Vessel Diameter mm D Demister Lenght mm Demister Thickness mm Vessel Lenght mm L

3500 1650 150 12000

GEOMETRICAL DATA TG-Demister Top Surf. h0 mm Liq-Liq Sep. Lenght L* mm Gas Outlet Nozzle - TL L1 mm Vessel L/D /

450 9000 850 3.43

HEAVY LIQUID PHASE LEVELS h2 BG-LLIL mm HIIi LLIL-LIL mm Hrli LIL-HIL mm Hii HIL-HHIL mm

300 150 350 150

LIGHT LIQUID PHASE LEVELS h2' HHIL-LLLL mm HII LLLL-LLL mm Hrl LLL-HLL mm HI HLL-HHLL mm

150 150 350 150

REV

DATE

DESCRIPTION

ISSUED

CHECKED

APPROVED

CUSTOMER xxxxxxxxx PLANT LOCATION xxxxxxxxxx PROJECT / UNIT xxxxxxxxxxxx RATING OUTPUT

JOB

UNIT

xxxxxxxxx
ITEM

xxxxx

Sh.

of

Rev.

SEPARATION DATA
GAS/LIQUID SEPARATION
(See Note 2)

HEAVY FROM LIGHT LIQUID PHASE SEPARATION

Light Liq. Drop. Diameter Calculated 'k' factor


DEMISTER

m m/s

55 9.57E-03
(See Note 3)

Drop.Diameter @ NIL-NILL Drop.Diameter @ HHIL-LLLL

m m

22 22

LIGHT FROM HEAVY LIQUID PHASE SEPARATION

Recommanded 'KR' Factor Calculated 'KR' Factor

m/s m/s

0.107 0.100

Drop.Diameter @ BG-NIL Drop.Diameter @ BG-LLIL

m m

18 21

RESIDENCE TIMES LLIL-LIL LIL-HIL HIL-HHIL HEAVY LIQUID PHASE IIi min rli min Ii min LLLL-LLL LLL-HLL HLL-HHLL LIGHT LIQUID PHASE II min rl min I min

46.70 136.67 67.22

6.73 16.37 7.16

Overfilling above HHLL

(See Note 4)

min

64.64

Inlet

Gas Outlet Light Liquid Outlet Heavy Liquid Outlet

NOZZLES m/s v Pa v2 Pa*m/s v3 m/s v Pa v2 Pa*m/s v3 m/s v Pa v2 Pa*m/s v3 m/s v Pa v2 Pa*m/s v3

7.58 812 87055 22.11 4436 98051 0.90 483 432 0.73 539 395

REV

DATE

DESCRIPTION

ISSUED

CHECKED

APPROVED

CUSTOMER xxxxxxxxx PLANT LOCATION xxxxxxxxxx PROJECT / UNIT xxxxxxxxxxxx RATING CALCULATIONS

JOB

UNIT

xxxxxxxxx
ITEM

xxxxx

Sh.

of

Rev.

h/D X [/]
h1/D
(HHLL-BG)/D (HLL-BG)/D (NLL-BG)/D (LLL-BG)/D (LLLL-BG)/D (HHIL-BG)/D (HIL-BG)/D (NIL-BG)/D (LIL-BG)/D

h2/D

0.50 0.50 0.46 0.41 0.36 0.31 0.27 0.23 0.18 0.13 0.09

GEOMETRICAL DATA Trasversal Area A L A V [m2] [m3] Av Vv 4.81 57.73 Aw Vw 4.81 57.73 At Vt 4.29 51.43 An Vn 3.68 44.16 Au Vu 3.08 37.02 Az' Vz' 2.59 31.07 Awi Vwi 2.11 25.34 Ati Vti 1.66 19.88 Ani Vni 1.16 13.97 Aui Vui 0.72 8.68 Az Vz 0.40 4.79

Head Volume Vf [m3] Vfv 2.81 Vfw 2.81 Vft 2.45 Vfn 2.03 Vfu 1.64 Vfz' 1.31 Vfwi 1.02 Vfti 0.75 Vfni 0.47 Vfui 0.25 Vfz 0.12

GAS-LIQUID SEPARATION
SEPARATION DATA
(See Note 7)

DEMISTER

Gravity Sep. Height h1 L0 Gas-Liq. Sep. Lenght Light Liq. Drop. Term. Vel. C/Re

mm mm m/s /

1750 10325 0.077 1.91E+00

'KR' Correction Factor Gas Velocity

/ m/s

1 0.81

LIQUID-LIQUID SEPARATION
HEAVY FROM LIGHT LIQUID PHASE SEPARATION

Light Liquid Sep. Level Heavy Liq. Drop.Term. Vel. C/Re

/ m/s /

NIL-NILL 5.77E-04 1.42E+04

HHIL-LLLL 5.70E-04 1.48E+04

LIGHT FROM HEAVY LIQUID PHASE SEPARATION

Heavy Liquid Sep. Level Light Liq. Drop. Term. Vel. C/Re

/ m/s /

BG-NIL 8.86E-05 5.68E+06

BG-LLIL 1.24E-04 2.07E+06

NOZZLES Gas Sound Velocity m/s Gas Phase Mass Fraction / Mixed Phase Density kg/m3 3 Total Liquid Density kg/m Mixed Phase Critical Vel. m/s

248.01 0.64 14.12 635.64 199.64

REV

DATE

DESCRIPTION

ISSUED

CHECKED

APPROVED

CUSTOMER xxxxxxxxx PLANT LOCATION


ENGINEERING AND DESIGN INSTITUTE FOR OIL REFINERIES AND PETROCHEMICAL PLANTS PLOIESTI - ROMANIA

JOB

UNIT

xxxxxxxxx
ITEM

xxxxx 0

xxxxxxxxxx PROJECT / UNIT xxxxxxxxxxxx RATING SKETCH


(See note 6)

Sh.

of

Rev.

12000

L0

(See Note 7)

pe

L1

O pe n

Pi

10325
NIN= 24 NG= 14

850

al f

TG
450 150

h0 1750 h1

1650

TL
MH= 24

3500

HHLL HLL LLL LLLL HHIL HIL LIL LLIL

HI Hrl HIl h2' HIi Hrli HIIi

BG Elliptical 2:1
NLh= 2 NLl= 6

h2

B-B

LIQUID LEVELS mm

LLIL LIL NIL HIL HHIL LLLL LLL NLL HLL HHLL

300 450 625 800 950 1100 1250 1425 1600 1750

Av

h1

Az

h2

B-B

REV

DATE

DESCRIPTION

ISSUED

CHECKED

APPROVED

CUSTOMER xxxxxxxxx PLANT LOCATION xxxxxxxxxx PROJECT / UNIT xxxxxxxxxxxx NOTES

JOB

UNIT

xxxxxxxxx
ITEM

xxxxx 0

Sh.

of

Rev.

Note 1: Note 2: Note 3: Note 4: Note 5: Note 6: Note 7:

Vessel shall be suitable for removal of 95% of 200400 m liquid particles. Mesh Pad Demister shall be suitable for removal of 99.9% of 10 m liquid particles. Light Liquid Droplet Separation from Gas @ HHLL For Operating Pressure P<0.1 barg and P>1 barg the 'KR' Demister Factor is extrapoleted. See PRG.PR.VES.0001 Paragraph 4.1.3. Overfilled is referred to Light Liquid Overflow Deleted All sizes are in mm, unless nozzle sizes are in inch. Gravity Separation Lenght (L0) is the distance between TL and Demister.