You are on page 1of 88

Use pursuant to applicable agreements

Title page

Alcatel-Lucent 9326
digital 2U Node B V2 | V7.1
Maintenance Guide

Alcatel-Lucent Proprietary
Use pursuant to applicable agreements

NN-20500-204
ISSUE 4.05
MAY 2010

Use pursuant to applicable agreements


Legal notice
Legal notice

Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective
owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright 2010 Alcatel-Lucent. All rights reserved.
Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside
Alcatel-Lucent without its written authorization.
Not to be used or disclosed except in accordance with applicable agreements.

Alcatel-Lucent Proprietary
Use pursuant to applicable agreements

Contents

About this document


Purpose

............................................................................................................................................................................................. ix
ix

Reason for revision

...................................................................................................................................................................... ix
ix

New in this release

....................................................................................................................................................................... ix
ix

Intended audience

......................................................................................................................................................................... ix
ix

Supported systems ........................................................................................................................................................................ ix


ix
How to use this document ........................................................................................................................................................... xx
Safety information

......................................................................................................................................................................... x
x

Prerequisites ..................................................................................................................................................................................... xx
Conventions used

........................................................................................................................................................................... x
x

Related information ....................................................................................................................................................................... xx


Document support

........................................................................................................................................................................ xi
xi

Technical support .......................................................................................................................................................................... xi


xi
How to order ................................................................................................................................................................................... xi
xi
How to comment ........................................................................................................................................................................... xi
xi
1

Roadmap to Distributed Base Stations documentation


Overview ....................................................................................................................................................................................... 1-1
1-1
Roadmap to Distributed Base Stations documentation

................................................................................................ 1-2

Safety statements
Overview ....................................................................................................................................................................................... 2-1
2-1
Structure of safety statements ................................................................................................................................................ 2-2
2-2

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
iii
Issue 4.05 May 2010
Use pursuant to applicable agreements

Contents
....................................................................................................................................................................................................................................

Corrective maintenance activity


Overview ....................................................................................................................................................................................... 3-1
3-1
Corrective maintenance activity

........................................................................................................................................... 3-2
3-2

9326 d2U V2 introduction


Overview ....................................................................................................................................................................................... 4-1
4-1
9326 d2U V2 introduction

...................................................................................................................................................... 4-2
4-2

9326 d2U V2 hardware presentation


Overview ....................................................................................................................................................................................... 5-1
5-1
9326 d2U V2 hardware presentation

.................................................................................................................................. 5-2

9326 d2U V2 power up and power down procedures


Overview ....................................................................................................................................................................................... 6-1
6-1
Powering up a 9326 d2U V2

................................................................................................................................................. 6-2

Powering down a 9326 d2U V2


7

........................................................................................................................................... 6-3

9326 d2U V2 corrective maintenance procedures


Overview ....................................................................................................................................................................................... 7-1
7-1
Replacing the digital shelf equipment
Overview ....................................................................................................................................................................................... 7-2
7-2
Replacing an iCEM-U .............................................................................................................................................................. 7-3
7-3
Replacing an xCEM-U ............................................................................................................................................................. 7-6
7-6
Replacing the iCCM-U

............................................................................................................................................................ 7-9
7-9

Replacing the xCCM-U

........................................................................................................................................................ 7-14
7-14

Replacing an optical transceiver


Replacing the fans rack (48V)

........................................................................................................................................ 7-20
7-20

............................................................................................................................................ 7-23
7-23

Replacing the pre-cabled 9326 d2U V2 rack

................................................................................................................ 7-28

Replacing the optional equipment


Overview

.................................................................................................................................................................................... 7-38
7-38

Replacing the External Alarm module ............................................................................................................................. 7-39


Replacing the LPPCM module

........................................................................................................................................... 7-41
7-41

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
iv
Use pursuant to applicable agreements
Issue 4.05 May 2010

Contents
....................................................................................................................................................................................................................................

Product conformance statements


Overview ...................................................................................................................................................................................... A-1
A-1
European regulatory requirement compliance

............................................................................................................... A-2

North American regulatory requirement compliance


Compliances for other regions/countries

.................................................................................................. A-4

......................................................................................................................... A-7

Operating conditions

............................................................................................................................................................... A-8
A-8

Cable specifications

................................................................................................................................................................. A-9
A-9

Product labeling

...................................................................................................................................................................... A-10
A-10

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
v
Issue 4.05 May 2010
Use pursuant to applicable agreements

List of figures

1-1

Roadmap to Distributed Base Stations documentation ................................................................................ 1-3

4-1

Outside view of the 9326 d2U V2

5-1

9326 d2U V2 front view (with iCCM-U)

......................................................................................................... 5-2

5-2

9326 d2U V2 front view (with xCCM-U)

........................................................................................................ 5-2

7-1

iCEM-U front panel

7-2

xCEM-U front panel ................................................................................................................................................. 7-6


7-6

7-3

iCCM-U board front panel

7-4

xCCM-U-4E1 configuration front panel

7-5

xCCM-U-GE configuration front panel .......................................................................................................... 7-14

7-6

Location of optical connectors in the 9326 d2U V2 ................................................................................... 7-21

7-7

Inserting an SFP transceiver in the iCCM-U

7-8

9326 d2U V2 front view (with iCCM-U) ....................................................................................................... 7-23

7-9

9326 d2U V2 front view (with xCCM-U) ...................................................................................................... 7-23

7-10

Extracting the fans rack

7-11

Fans rack

7-12

9326 d2U V2 front view (with iCCM-U) ....................................................................................................... 7-28

7-13

9326 d2U V2 front view (with xCCM-U) ...................................................................................................... 7-28

7-14

Location of the management sticker

7-15

Front panel of the External Alarm module

7-16

LPPCM module front panel

....................................................................................................................... 4-3

.................................................................................................................................................. 7-3
7-3

..................................................................................................................................... 7-9
........................................................................................................ 7-14

................................................................................................ 7-22

........................................................................................................................................ 7-25

.................................................................................................................................................................... 7-25
7-25

................................................................................................................ 7-30
.................................................................................................... 7-39

................................................................................................................................ 7-41

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
vii
Issue 4.05 May 2010
Use pursuant to applicable agreements

About this document


About this document

Purpose

The purpose of this document is to describe corrective maintenance procedures applicable


to the 9326 d2U V2 rack.
Reason for revision

The reissue reasons are:


Issue number

Issue date

Reason for reissue

4.05

May 2010

Standard issue

4.04

March 2010

Preliminary issue

4.03

February 2010

Preliminary issue

4.02

November 2009

Preliminary issue

4.01

October 2009

Draft issue

New in this release

New features:

74759 Gigabit Ethernet MDA for xCCM, see Replacing the xCCM-U (p. 7-14)
Important! The availability of the features listed above on the hardware equipment
should be checked with your Alcatel-Lucent representative.

Other changes:

Reformat to comply with current documentation standards

Intended audience

The audience for this document is Operations and maintenance personnel and those who
want to know the principles of 9326 d2U V2 maintenance.
Supported systems

This document applies to Alcatel-Lucent W-CDMA V7.1 system release.

...................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
ix
Issue 4.05 May 2010
Use pursuant to applicable agreements

About this document


....................................................................................................................................................................................................................................

How to use this document

No specific recommendation applies regarding the way readers should read this
document.
Safety information

For your safety, this document contains safety statements. Safety statements are given at
points where risks of damage to personnel, equipment, and operation may exist. Failure to
follow the directions in a safety statement may result in serious consequences.
Prerequisites

It is recommended that readers become familiar with the following documents:

Alcatel-Lucent 9326 digital 2U Node B V2 - Technical Description, NN-20500-203


Alcatel-Lucent 93xx Node B Commissioning and Fault Management User Manual:
TIL, NN-20500-019

Conventions used
Vocabulary conventions

For a list of terms used in this document, see Alcatel-Lucent W-CDMA System Terminology, NN-20500-002.
Typographical conventions

The following typographical conventions are used in this document:


Appearance

Description

Italicized text

Emphasized information

graphical user interface text

Text that is displayed in a graphical user interface or


in a hardware label

Document reference, reference number

Related document that is referenced in the document

Related information

For information on subjects related to the content of this document, refer to the
documents listed in the following table:
Refer to this document

At this location

For more information on

Alcatel-Lucent W-CDMA
System - Terminology,
NN-20500-002

http://support.alcatellucent.com.

Terms used in Alcatel-Lucent


W-CDMA documents.

Alcatel-Lucent 9326 digital


2U Node B V2 - Technical
Description, NN-20500-203

http://support.alcatellucent.com.

The Alcatel-Lucent 9326


digital 2U Node B V2:

Basic characteristics

Hardware description

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
x
Use pursuant to applicable agreements
Issue 4.05 May 2010

About this document


....................................................................................................................................................................................................................................

Refer to this document

At this location

For more information on

Alcatel-Lucent 9353
Wireless Management
System - Node B Alarms
Reference Guide for 9311,
9312, 9322, 9326, 9332
Node B, NN-20500-018P1

http://support.alcatellucent.com.

Alarm descriptions and


maintenance actions required
for Alcatel-Lucent Node Bs.

Alcatel-Lucent 9353
Wireless Management
System - User Guide,
NN-20500-032

http://support.alcatellucent.com.

How to perform commands


available in the 9353 Wireless
Management System (WMS)
Graphical User Interface
(GUI).

Alcatel-Lucent 93xx Node B


Commissioning and Fault
Management User Manual:
TIL, NN-20500-019

http://support.alcatellucent.com.

How to perform the Node B


installation, commissioning
and maintenance tasks using
the Node B TIL (Terminal for
Local Installation) tool.

Alcatel-Lucent W-CDMA
System Safety Guide,
401-382-880

http://support.alcatellucent.com.

Safety guidelines and the


catalog of hazard statements
that appear in the
Alcatel-Lucent W-CDMA
customer documents.

Document support

For support in using this or any other Alcatel-Lucent document, contact Alcatel-Lucent at
one of the following telephone numbers:

1-888-582-3688 (for the United States)


1-317-377-8618 (for all other countries)

Technical support

For technical support, contact your local Alcatel-Lucent customer support team. See the
Alcatel-Lucent Support web site (http://www.alcatel-lucent.com/support/) for contact
information.
How to order

To order Alcatel-Lucent documents, contact your local sales representative or use Online
Customer Support (OLCS) (http://support.alcatel-lucent.com)
How to comment

To comment on this document, go to the Online Comment Form (http://infodoc.


alcatel-lucent.com/comments/enus/) or e-mail your comments to the Comments Hotline
(comments@alcatel-lucent.com).
....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
xi
Issue 4.05 May 2010
Use pursuant to applicable agreements

1oadmap to Distributed
R
Base Stations
documentation

Overview
Purpose

This chapter provides the roadmap for Distributed Base Stations documentation.
Contents
Roadmap to Distributed Base Stations documentation

1-2

...................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
1-1
Issue 4.05 May 2010
Use pursuant to applicable agreements

Roadmap to Distributed Base Stations documentation

Roadmap to Distributed Base Stations documentation

....................................................................................................................................................................................................................................

Roadmap to Distributed Base Stations documentation


The following figure shows where the current document stands within the W-CDMA
customer documentation.
For a global view of the W-CDMA customer documentation, see the Roadmap chapter in:

Alcatel-Lucent W-CDMA System - Document Collection Overview, NN-20500-050


Alcatel-Lucent W-CDMA System - Access Network Elements Overview,
NN-20500-233

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
1-2
Use pursuant to applicable agreements
Issue 4.05 May 2010

Roadmap to Distributed Base Stations documentation

Roadmap to Distributed Base Stations documentation

....................................................................................................................................................................................................................................

Figure 1-1 Roadmap to Distributed Base Stations documentation

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
1-3
Issue 4.05 May 2010
Use pursuant to applicable agreements

Safety statements
2

Overview
Purpose

This chapter provides information on the structure of safety statements which may arise
in the course of your work.
Contents
Structure of safety statements

2-2

...................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
2-1
Issue 4.05 May 2010
Use pursuant to applicable agreements

Safety statements

Structure of safety statements

....................................................................................................................................................................................................................................

Structure of safety statements


Overview

Safety statements describe the safety risks relevant while performing tasks on
Alcatel-Lucent products during deployment and/or use. Failure to avoid the hazards may
have serious consequences.
General structure

Safety statements include the following structural elements:

D
CAUTION
Lifting hazard

Lifting this equipment by yourself can result in injury


due to the size and weight of the equipment.
Always use three people or a lifting device to transport
and position this equipment.
[ABC123]

F
G
H

Item

Structure element

Purpose

Safety alert symbol

Indicates the potential for personal injury


(optional)

Safety symbol

Indicates hazard type (optional)

Signal word

Indicates the severity of the hazard

Hazard type

Describes the source of the risk of damage or


injury

Safety message

Consequences if protective measures fail

Avoidance message

Protective measures to take to avoid the hazard

Identifier

The reference ID of the safety statement


(optional)

Signal words

The signal words identify the hazard severity levels as follows:


Signal word

Meaning

DANGER

Indicates an extremely hazardous situation which, if not avoided, will


result in death or serious injury.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
2-2
Use pursuant to applicable agreements
Issue 4.05 May 2010

Safety statements

Structure of safety statements

....................................................................................................................................................................................................................................

Signal word

Meaning

WARNING

Indicates a hazardous situation which, if not avoided, could result in


death or serious injury.

CAUTION

Indicates a hazardous situation which, if not avoided, could result in


minor or moderate injury.

NOTICE

Indicates a hazardous situation not related to personal injury.

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
2-3
Issue 4.05 May 2010
Use pursuant to applicable agreements

3 orrective maintenance
C
activity

Overview
Purpose

This chapter describes the corrective maintenance activity applicable to the 9326 d2U V2
rack.
Contents
Corrective maintenance activity

3-2

...................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
3-1
Issue 4.05 May 2010
Use pursuant to applicable agreements

Corrective maintenance activity

Corrective maintenance activity

....................................................................................................................................................................................................................................

Corrective maintenance activity


Corrective maintenance

The network maintenance is based on the supervision of the network, by using the OAM
graphical interface. For more information, refer to Alcatel-Lucent 9353 Wireless
Management System - User Guide, NN-20500-032.
It is also based on the identification and replacement of faulty items of equipment, using
the alarms.
The process is divided into the following two steps:

Locating and identifying the faulty items of equipment, by using the information
provided in Alcatel-Lucent 9353 Wireless Management System - Node B Alarms
Reference Guide for 9311, 9312, 9322, 9326, 9332 Node B, NN-20500-018P1
Replacing the faulty items of equipment, by using the replacement procedures given
in this document
Note: The iModules replacement procedures described in this guide are based on the
following assumptions:

Your 9326 d2U V2 is equipped with the following digital modules:


One iCCM-U upgraded with the specific adapter board and front panel (iCCM-U
V2)
One xCEM-U (mandatory) and possibly up to two additional xCEMs-U

Possibly up to two iCEMs-U upgraded with the specific adapter boards and front
panels (iCEMs-U V2)
As spare parts, you ordered iCEMs-U V2 and iCCMs-U V2 modules (order codes:
3JR08057AA and 3JR08056AA).

Replacing the digital shelf equipment


Procedure

Order Code

Impact on service

Replacing an iCEM-U
(p. 7-3)

3JR08057AA

Loss of capacity or loss of service


(depending on the number of CEMs in
the digital shelf)

Replacing an xCEM-U
(p. 7-6)

300986049

Loss of capacity or loss of service


(depending on the number of CEMs in
the digital shelf)

Replacing the iCCM-U


(p. 7-9)

3JR08056AA

Loss of service on the Remote Radio


device(s) associated with the iCCM-U
being replaced

Replacing the xCCM-U


(p. 7-14)

3JR20038AA

Loss of service on the Remote Radio


device(s) associated with the xCCM-U
being replaced

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
3-2
Use pursuant to applicable agreements
Issue 4.05 May 2010

Corrective maintenance activity

Corrective maintenance activity

....................................................................................................................................................................................................................................

Procedure
Replacing an optical
transceiver (p. 7-20)

Order Code
Single-Mode (SM):
NTU850HA
Multi-Mode (MM):
NTU850HM

Impact on service
Loss of service on the Remote Radio
device associated with the optical
transceiver being replaced

Replacing the fans rack


(48V) (p. 7-23)

3JR08021AA

Service interruption

Replacing the pre-cabled


9326 d2U V2 rack
(p. 7-28)

3JR08067AA

Service interruption

Replacing the optional equipment


Procedure

Order Code

Impact on service

Replacing the LPPCM


module (p. 7-41)

NTU870GM

Service interruption

Replacing the External


Alarm module (p. 7-39)

NTU870GA

None

Description of a replacement procedure

A replacement procedure is divided into the following parts:

The title
The main body with the following information:
The intervention time
The tools required

The impact of the procedure, if necessary


The step-by-step actions of the procedure

One or more figures are provided to help you execute the actions. They show the FRU
schematically and its location in the cabinet.
Intervention restrictions

There may be a lapse of time between the identification of the alarm at the Access OAM
Graphic User Interface (GUI) and the time you arrive at the site.
You must be synchronized with the access network controller or system administrator (by
telephone) before an on-site intervention, in the following cases:

Isolating procedures
Completion of an on-site intervention
Return to service procedure

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
3-3
Issue 4.05 May 2010
Use pursuant to applicable agreements

Corrective maintenance activity

Corrective maintenance activity

....................................................................................................................................................................................................................................

General personnel safety instructions

The personnel must obey the safety instructions specific to the installation site:

Rules concerning the premises (see instructions posted on site or in the building)

Rules linked to general personnel safety instructions

The personnel working on the cabinet must be authorized to work according to security
standards.
Equipment safety instructions

The 9326 d2U V2 normally operates when the external temperature is between 5C and
+65C.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
3-4
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 introduction


4

Overview
Purpose

This chapter introduces the 9326 d2U V2.


Contents
9326 d2U V2 introduction

4-2

...................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
4-1
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 introduction

9326 d2U V2 introduction

....................................................................................................................................................................................................................................

9326 d2U V2 introduction


The 9326 d2U V2 is the enhanced 9326 d2U rack supporting xModules (xCEM-U,
xCCM-U). It is designed to be connected to one of the following products via optical
fiber links:

RRH60-21
RRH40-AWS

RRH40-21
RRH40-08
RRH40-19

RRH20-21
9332 rCompact

The iModules (iCEM-U, iCCM-U) can be plugged in this 9326 d2U V2 rack, using
specific adapter boards and front panels.
xCEM-U and iCEM-U modules can be mixed inside the 9326 d2U V2 rack. The 9326
d2U V2 rack is factory-equipped with one xCCM-U or one iCCM-U (in slot 1), one
xCEM-U (in slot 2) and two fillers. Depending on the capacity requirements, the 9326
d2U V2 rack can host two xCEMs-U, two iCEMs-U, or one xCEM-U and one iCEM-U
in place of the two fillers (slot 3 and slot 4).
The Alcatel-Lucent Remote Radio solution improves flexibility for deploying mobile
broadband Node Bs in space-constrained locations. It is particularly suited to
macro-cellular applications in dense areas, where site acquisition is difficult, and on sites
where installation constraints prevent the use of legacy Node Bs.
Compared to legacy Node B site deployment, the Remote Radio solution provides the
following benefits:

Reduced volume, weight, footprint, acoustic noise, and power consumption


Reduced cost of feeder paths from the Node B to the antenna

Increased RF power per carrier at the antenna feeder


Reduced radio loss with use of the remote RF block concept, which eliminates the
distance between the radio amplifier and the antenna

The Remote Radio solution provides for the UMTS system:

The means of communication between a User Equipment (UE) and a network using
Transport Channels
Physical layer channels, which are necessary to synchronize the downlink and
perform cell selection/reselection and handover preparation
Measurement information to the RNC for radio resource management (handover,
power control)

The 9326 d2U V2 provides up to eight E1/T1 with Inversion Multiplexing ATM (IMA) or
Drop-and-Insert capability (fractional E1/T1). The 9326 d2U V2 also supports
multi-PCM without IMA.
....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
4-2
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 introduction

9326 d2U V2 introduction

....................................................................................................................................................................................................................................

The 9326 d2U V2 delivers high UMTS radio performances and supports the enhanced
High Speed Downlink Packet Access (HSDPA) and High Speed Uplink Packet Access
(HSUPA) solutions through easy software upgrade.
The 9326 d2U V2 is compliant with the Common Public Radio Interface (CPRI).
9326 d2U V2 enclosure

The 9326 d2U V2 provides the operators with a suited solution whatever the site
constraints.
The 9326 d2U V2 can be installed in a standalone indoor mode or in an existing indoor or
outdoor Alcatel-Lucent 9100 Multi-Standard Base Station cabinet for multi-standard
configuration.
Moreover, the 9326 d2U V2 can be integrated in a small or a medium Power Supply Unit
(PSU) outdoor cabinet.
The following figure shows an outside view of the 9326 d2U V2.
Figure 4-1 Outside view of the 9326 d2U V2

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
4-3
Issue 4.05 May 2010
Use pursuant to applicable agreements

5326 d2U V2 hardware


9
presentation

Overview
Purpose

This chapter describes the hardware of the 9326 d2U V2 rack.


Contents
9326 d2U V2 hardware presentation

5-2

...................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
5-1
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 hardware presentation

9326 d2U V2 hardware presentation

....................................................................................................................................................................................................................................

9326 d2U V2 hardware presentation


The 9326 d2U V2 is built around the following components:

A mechanical enclosure (including two fans), compatible with standard 19-inch rack
installation
A digital shelf including the digital modules and the associated digital backplane
A commissioning module located on the right hand side of the digital shelf

The following figure shows a front view of the 9326 d2U V2 equipped with iCCM-U.
Figure 5-1 9326 d2U V2 front view (with iCCM-U)

The following figure shows a front view of the 9326 d2U V2 equipped with xCCM-U.
Figure 5-2 9326 d2U V2 front view (with xCCM-U)

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
5-2
Use pursuant to applicable agreements
Issue 4.05 May 2010

6326 d2U V2 power up


9
and power down
procedures

Overview
Purpose

This chapter describes how to power up and power down the 9326 d2U V2.
Contents
Powering up a 9326 d2U V2

6-2

Powering down a 9326 d2U V2

6-3

...................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
6-1
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 power up and power down procedures

Powering up a 9326 d2U V2

....................................................................................................................................................................................................................................

Powering up a 9326 d2U V2


Perform the following procedure to power up a 9326 d2U V2.
Initial check

On the RUC module, check that the power switch is in the "O" position.
Procedure
...................................................................................................................................................................................................

At the operator DC power supply, put the site circuit breaker of the 9326 d2U V2 in the
"ON" position.
...................................................................................................................................................................................................

On the RUC module, put the power switch in the "1" position.
...................................................................................................................................................................................................

Check that the fans are starting up.


...................................................................................................................................................................................................

On the iCCM-U/xCCM-U and on each iCEM-U/xCEM-U, check that:

The green LED is ON.


The red LED is OFF.

E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
6-2
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 power up and power down procedures

Powering down a 9326 d2U V2

....................................................................................................................................................................................................................................

Powering down a 9326 d2U V2


Perform the following procedure to power down a 9326 d2U V2.
Procedure
...................................................................................................................................................................................................

Preliminary operation: make sure that the btsSiteManager object is "locked".


...................................................................................................................................................................................................

On the RUC module, put the power switch in the "O" position.
...................................................................................................................................................................................................

Check that the green or red LED on the iCCM-U/xCCM-U and on each
iCEM-U/xCEM-U is OFF.
...................................................................................................................................................................................................

Check that the fans are stopping down.


...................................................................................................................................................................................................

At the operator DC power supply, put the site circuit breaker of the 9326 d2U V2 in the
"OFF" position.
E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
6-3
Issue 4.05 May 2010
Use pursuant to applicable agreements

7326 d2U V2 corrective


9
maintenance procedures

Overview
Purpose

This chapter contains the replacement procedures applicable to the 9326 d2U V2 rack.
Note:
1. For detailed information on PSU maintenance, refer to the documentation
provided within the PSU cabinet.
2. For detailed information on Alcatel-Lucent 9100 Multi-Standard Base Station
maintenance, refer to the documentation related to the Alcatel-Lucent 9100
Multi-Standard Base Station cabinets.
Contents
Replacing the digital shelf equipment

7-2

Replacing an iCEM-U

7-3

Replacing an xCEM-U

7-6

Replacing the iCCM-U

7-9

Replacing the xCCM-U

7-14

Replacing an optical transceiver

7-20

Replacing the fans rack (48V)

7-23

Replacing the pre-cabled 9326 d2U V2 rack

7-28

Replacing the optional equipment

7-38

Replacing the External Alarm module

7-39

Replacing the LPPCM module

7-41

...................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-1
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Overview

....................................................................................................................................................................................................................................

Replacing the digital shelf equipment


Overview
Purpose

This section presents the replacement procedures applicable to the digital shelf.
Those replacement procedures concern the following modules:

integrated Channel Element Module-U (iCEM-U) or eXtended Channel Element


Module-U (xCEM-U)
integrated Core Controller Module-U (iCCM-U) or eXtended Core Controller
Module-U (xCCM-U)
Optical transceiver

Fans rack (48V)


Pre-cabled 9326 d2U V2 rack

Contents
Replacing an iCEM-U

7-3

Replacing an xCEM-U

7-6

Replacing the iCCM-U

7-9

Replacing the xCCM-U

7-14

Replacing an optical transceiver

7-20

Replacing the fans rack (48V)

7-23

Replacing the pre-cabled 9326 d2U V2 rack

7-28

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-2
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing an iCEM-U

....................................................................................................................................................................................................................................

Replacing an iCEM-U
Carry out the following procedure to replace an iCEM-U.
Intervention time

15 minutes
Tools required

Screwdrivers
Extraction tool
Figure 7-1 iCEM-U front panel

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.

NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of capacity or a loss of service
(depending on the number of CEMs housed in the 9326 d2U V2 rack).
Procedure
...................................................................................................................................................................................................

Locate the faulty iCEM-U in the 9326 d2U V2 rack: its red triangular LED is ON.

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-3
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing an iCEM-U

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

Lock the faulty cem object at the OMC by Set Administrative State.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, NN-20500-032.
...................................................................................................................................................................................................

Undo and remove the upper hook (if present and if the defective iCEM-U is in slot 4).

...................................................................................................................................................................................................

Loosen the two screws on the defective iCEM-U front panel.


...................................................................................................................................................................................................

Remove the defective iCEM-U using the extraction tool.


...................................................................................................................................................................................................

If you are to replace the defective iCEM-U with a xCEM-U, go to step 6 of the procedure
Replacing an xCEM-U (p. 7-6).
If you are to replace the defective iCEM-U with a new iCEM-U, check the release of the
new iCEM-U.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-4
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing an iCEM-U

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

Insert the new iCEM-U into the 9326 d2U V2 rack, in the same slot as the defective
iCEM-U.

...................................................................................................................................................................................................

Tighten the two screws on the iCEM-U front panel.


...................................................................................................................................................................................................

Put the hook back in place and secure it.


...................................................................................................................................................................................................

10

From the OMC, unlock the cem object previously locked on step 2.
...................................................................................................................................................................................................

11

Check the state of the LEDs. They should go on, then take the following state:
red triangular LED OFF and green rectangular LED ON.
E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-5
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing an xCEM-U

....................................................................................................................................................................................................................................

Replacing an xCEM-U
Carry out the following procedure to replace an xCEM-U.
Intervention time

Ten minutes
Tools required

Screwdriver
Extraction tool
Figure 7-2 xCEM-U front panel

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.

NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of capacity or a loss of service
(depending on the number of CEMs housed in the 9326 d2U V2 rack).
Procedure
...................................................................................................................................................................................................

Locate the faulty xCEM-U in the 9326 d2U V2 rack: its red LED is ON.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-6
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing an xCEM-U

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

Lock the faulty cem object at the OMC by Set Administrative State.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, NN-20500-032.
...................................................................................................................................................................................................

Undo and remove the upper hook (if present and if the defective xCEM-U is in slot 4).

...................................................................................................................................................................................................

Loosen the two screws on the xCEM-U front panel.


...................................................................................................................................................................................................

Remove the defective xCEM-U using the extraction tool.


...................................................................................................................................................................................................

Check the release of the new xCEM-U.


...................................................................................................................................................................................................

Insert the new xCEM-U into the 9326 d2U V2 rack, in the same slot as the defective
xCEM-U.

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-7
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing an xCEM-U

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

Tighten the two screws on the xCEM-U front panel.


...................................................................................................................................................................................................

Put the hook back in place and secure it.


...................................................................................................................................................................................................

10

From the OMC, unlock the cem object previously locked on step 2.
...................................................................................................................................................................................................

11

Check the state of the LEDs. They should go on, then take the following state:
red triangular LED OFF and green rectangular LED ON.
E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-8
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the iCCM-U

....................................................................................................................................................................................................................................

Replacing the iCCM-U


Carry out the following procedure to replace the iCCM-U.
Intervention time

20 minutes
Tools required

Screwdrivers
Extraction tool
Figure 7-3 iCCM-U board front panel

DANGER
Laser hazard
This equipment operates with invisible laser radiation. Laser radiation can cause
considerable injuries to the eyes.
Never look into the end of an exposed fiber or into an open optical connector when the
optical source is switched on. Always observe the laser warning instructions.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.
....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-9
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the iCCM-U

....................................................................................................................................................................................................................................

NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
Important! The spare iCCM-U software load must be UA05.1.2, otherwise the 9326
d2U V2 can not start.
Important! There will be a loss of service on the Remote Radio device(s) associated
with the iCCM-U being replaced.
Procedure
...................................................................................................................................................................................................

Lock all the objects associated with the Remote Radio devices connected to the faulty
iCCM-U at the OMC by Set Administrative State.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, NN-20500-032.
...................................................................................................................................................................................................

Power down the 9326 d2U V2.


To do this, follow the procedure Powering down a 9326 d2U V2 (p. 6-3).
...................................................................................................................................................................................................

Undo and remove the lower hook (if present).

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-10
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the iCCM-U

....................................................................................................................................................................................................................................

...................................................................................................................................................................................................

Loosen the two screws on the defective iCCM-U front panel.


...................................................................................................................................................................................................

Unplug the iCCM-U from its RBP connectors using the extraction tool.
...................................................................................................................................................................................................

Disconnect the optical fiber(s) from the iCCM-U front panel.


...................................................................................................................................................................................................

Remove the SFP transceiver(s) from the iCCM-U front panel.


...................................................................................................................................................................................................

Disconnect the digital cable (connector labeled "ALARM") from the iCCM-U front
panel.
...................................................................................................................................................................................................

Disconnect the E1/T1 connector (PCM link) from the iCCM-U front panel.
...................................................................................................................................................................................................

10

Extract the defective iCCM-U using the extraction tool.

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-11
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the iCCM-U

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

11

Insert the new iCCM-U into the slot guides without plugging it on the RBP.
...................................................................................................................................................................................................

12

Reinsert the SFP transceiver(s) through the iCCM-U front panel.


...................................................................................................................................................................................................

13

Important! In case of an iCCM-U equipped with MM SFP transceivers, when


reconnecting the optical fibers on the iCCM-U front panel, put the LC connectors
(L/R) in the same sense as they were before the intervention.
Reconnect the optical fiber(s) on the iCCM-U front panel.
...................................................................................................................................................................................................

14

Reconnect the digital cable on the iCCM-U front panel.


...................................................................................................................................................................................................

15

Insert completely the new iCCM-U into the 9326 d2U V2 rack by plugging it into its RBP
connectors.

...................................................................................................................................................................................................

16

Tighten the two screws on the iCCM-U front panel.


...................................................................................................................................................................................................

17

Put the hook back in place and secure it.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-12
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the iCCM-U

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

18

Important! If the iCCM-U software load is not UA05.1.2, the 9326 d2U V2 can not
start.
Power up the 9326 d2U V2.
To do this, follow the procedure Powering up a 9326 d2U V2 (p. 6-2)
...................................................................................................................................................................................................

19

Reconnect the PCM E1/T1 cable on the iCCM-U front panel.


...................................................................................................................................................................................................

20

Unlock from the OMC the objects previously locked through step 1.
...................................................................................................................................................................................................

21

Check the state of the LEDs and display:

The i/xCEM(s)-U and iCCM-U corporate LEDs should turn on, then take the
following state:
red LED OFF and green LED ON.
The green PCM LEDs should be ON.

The display should indicate the PCM synchronization.

E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-13
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the xCCM-U

....................................................................................................................................................................................................................................

Replacing the xCCM-U


Carry out the following procedure to replace the xCCM-U.
Intervention time

20 minutes
Tools required

Screwdrivers
Extraction tool
Figure 7-4 xCCM-U-4E1 configuration front panel

Figure 7-5 xCCM-U-GE configuration front panel

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-14
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the xCCM-U

....................................................................................................................................................................................................................................

DANGER
Laser hazard
This equipment operates with invisible laser radiation. Laser radiation can cause
considerable injuries to the eyes.
Never look into the end of an exposed fiber or into an open optical connector when the
optical source is switched on. Always observe the laser warning instructions.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.

NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
Procedure
...................................................................................................................................................................................................

Important! There will be a loss of service on the Remote Radio device(s) associated
with the xCCM-U being replaced.
Lock all the objects associated with the Remote Radio devices connected to the faulty
xCCM-U at the OMC by Set Administrative State.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, NN-20500-032.
...................................................................................................................................................................................................

Power down the 9326 d2U V2.


To do this, follow the procedure Powering down a 9326 d2U V2 (p. 6-3).
...................................................................................................................................................................................................

Undo and remove the lower hook (if present).

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-15
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the xCCM-U

....................................................................................................................................................................................................................................

...................................................................................................................................................................................................

Loosen the two screws on the defective xCCM-U front panel.


...................................................................................................................................................................................................

Unplug the xCCM-U from its RBP connectors using the extraction tool.
...................................................................................................................................................................................................

Disconnect the GPS cable (connector labeled GPS) from the xCCM-U front panel if
used.
...................................................................................................................................................................................................

Disconnect the optical fiber(s) and remove the SFP transceiver(s) (connector(s) labeled
OPTIC) from the xCCM-U front panel.
...................................................................................................................................................................................................

Disconnect the digital cable (connector labeled "ALARM") from the xCCM-U front
panel.
...................................................................................................................................................................................................

Disconnect the TIL cable (labeled PORT 1) from the xCCM-U front panel.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-16
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the xCCM-U

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

10
If...

Then...

The xCCM-U hardware configuration is


xCCM-U-4E1

Disconnect the two E1/T1 connectors (labeled


PCM E1/T1 and MDA) from the
xCCM-U front panel.
If the hybrid Iub interface is implemented,
disconnect the Ethernet connector (labeled
PORT 2).

The xCCM-U hardware configuration is


xCCM-U-GE

Disconnect the Gigabit Ethernet cable(s) and


remove the SFP transceiver(s) (labeled
MDA) from the xCCM-U front panel.

...................................................................................................................................................................................................

11

Extract the defective xCCM-U using the extraction tool.


...................................................................................................................................................................................................

12

Insert the new xCCM-U into the slot guides without plugging it on the RBP.
...................................................................................................................................................................................................

13

Reconnect the GPS cable (connector labeled GPS) on the xCCM-U front panel if used.
...................................................................................................................................................................................................

14

Reinsert the SFP transceiver(s) (connector(s) labeled OPTIC) through the xCCM-U
front panel.
...................................................................................................................................................................................................

15

Important! In case of an xCCM-U equipped with MM SFP transceivers, when


reconnecting the optical fibers on the xCCM-U front panel, put the LC connectors
(L/R) in the same sense as they were before the intervention.
Reconnect the optical fiber(s) (connector(s) labeled OPTIC) on the xCCM-U front
panel.
...................................................................................................................................................................................................

16

Reconnect the digital cable (connector labeled "ALARM") on the xCCM-U front panel.
...................................................................................................................................................................................................

17

Reconnect the TIL cable (labeled PORT 1) on the xCCM-U front panel.

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-17
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the xCCM-U

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

18
If...

Then...

The xCCM-U hardware configuration is


xCCM-U-GE

Reinsert the SFP transceiver(s) (connector(s)


labeled MDA) through the xCCM-U front
panel.
Reconnect the Gigabit Ethernet cable(s)
(labeled MDA) on the xCCM-U front panel.

...................................................................................................................................................................................................

19

Insert completely the new xCCM-U into the 9326 d2U V2 rack by plugging it into its
RBP connectors.
...................................................................................................................................................................................................

20

Tighten the two screws on the xCCM-U front panel.


...................................................................................................................................................................................................

21

Put the hook back in place and secure it.


...................................................................................................................................................................................................

22

Power up the 9326 d2U V2.


To do this, follow the procedure Powering up a 9326 d2U V2 (p. 6-2)
...................................................................................................................................................................................................

23
If...

Then...

The xCCM-U hardware configuration is


xCCM-U-4E1

Reconnect the two E1/T1 connectors (labeled


PCM E1/T1 and MDA) on the xCCM-U
front panel.
If the hybrid Iub interface is implemented,
reconnect the Ethernet connector (labeled
PORT 2).

...................................................................................................................................................................................................

24

Unlock from the OMC the objects previously locked through step 1.
...................................................................................................................................................................................................

25

Check the state of the LEDs and display:

The i/xCEM(s)-U and xCCM-U corporate LEDs should turn on, then take the
following state:
red LED OFF and green LED ON
The green PCM LEDs should be ON.

The green MDA LEDs should be ON.


The green/amber SYNC LEDs should indicate the PCM/MDA synchronization.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-18
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the xCCM-U

....................................................................................................................................................................................................................................

E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-19
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing an optical transceiver

....................................................................................................................................................................................................................................

Replacing an optical transceiver


Carry out the following procedure to replace a defective optical transceiver.
Intervention time

Five minutes
Tools required

None

DANGER
Laser hazard
This equipment operates with invisible laser radiation. Laser radiation can cause
considerable injuries to the eyes.
Never look into the end of an exposed fiber or into an open optical connector when the
optical source is switched on. Always observe the laser warning instructions.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.
Procedure
...................................................................................................................................................................................................

Locate the faulty SFP transceiver: its two green RX/TX OPTIC LEDs (close to the eight
PCM LEDs on an iCCM-U, built-in LEDs on an xCCM-U) are OFF.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-20
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing an optical transceiver

....................................................................................................................................................................................................................................

Figure 7-6 Location of optical connectors in the 9326 d2U V2

...................................................................................................................................................................................................

At the OMC, through Set Administrative State, lock the FDDCell object associated with
the Remote Radio device connected to the optical transceiver being replaced.
...................................................................................................................................................................................................

Disconnect the optical fiber connected to the defective SFP transceiver (optical output
labeled "OPTIC1/2/3" on the iCCM-U front panel, "OPTIC1/2/3/4/5/6" on the xCCM-U
front panel).
...................................................................................................................................................................................................

Extract with care the defective SFP transceiver.


...................................................................................................................................................................................................

Check that the new replacing SFP transceiver has the same type as the SFP transceiver
being replaced.Be sure to replace a SM SFP transceiver with a SM SFP transceiver and a
MM SFP transceiver with a MM SFP transceiver.

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-21
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing an optical transceiver

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

Put in place the new SFP transceiver and insert it in the i/xCCM-U.
Figure 7-7 Inserting an SFP transceiver in the iCCM-U

...................................................................................................................................................................................................

Reconnect the optical fiber.


...................................................................................................................................................................................................

Unlock from the OMC the FDDCell object previously locked through step 2.
...................................................................................................................................................................................................

Check the state of the two green RX/TX OPTIC LEDs: they should be ON.
E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-22
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the fans rack (48V)

....................................................................................................................................................................................................................................

Replacing the fans rack (48V)


Carry out the following procedure to replace the fans rack when alarmed.
Intervention time

15 minutes
Tools required

None
Figure 7-8 9326 d2U V2 front view (with iCCM-U)

Figure 7-9 9326 d2U V2 front view (with xCCM-U)

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.
....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-23
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the fans rack (48V)

....................................................................................................................................................................................................................................

NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
Procedure
...................................................................................................................................................................................................

Lock the cem object as well as all the objects associated with the Remote Radio devices
connected to the i/xCCM-U at the OMC, by Set Administrative State.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, NN-20500-032.
...................................................................................................................................................................................................

Power down the 9326 d2U V2.


To do this, follow the procedure Powering down a 9326 d2U V2 (p. 6-3).
...................................................................................................................................................................................................

Disconnect the 48V Power cable (3JR08080AA or 3JR08081AA) from the RUC front
panel.
...................................................................................................................................................................................................

Disconnect the Dallas one-wire cable ("INT" - NTU872JA) from the RUC front panel.
...................................................................................................................................................................................................

Disconnect the Dallas one-wire cable ("ALARM" - RJ45 connector to the i/xCCM-U 3JR22028AA) from the RUC front panel.
...................................................................................................................................................................................................

Extract the defective fans rack using the two handles on top and bottom of the RUC front
panel.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-24
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the fans rack (48V)

....................................................................................................................................................................................................................................

Figure 7-10 Extracting the fans rack

Figure 7-11 Fans rack

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-25
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the fans rack (48V)

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

Put the new fans rack in place and insert it completely into the 9326 d2U V2.
...................................................................................................................................................................................................

Reconnect the Dallas one-wire cable (3JR22028AA - "ALARM") on the RUC front
panel.
...................................................................................................................................................................................................

Reconnect the Dallas one-wire cable (NTU872JA - "INT") on the RUC front panel.
...................................................................................................................................................................................................

10

Reconnect the 48V Power cable (3JR08080AA or 3JR08081AA) on the RUC front
panel.
...................................................................................................................................................................................................

11

Power up the new 9326 d2U V2.


To do this, follow the procedure Powering up a 9326 d2U V2 (p. 6-2)
...................................................................................................................................................................................................

12

Unlock from the OMC the objects previously locked through step 1.
...................................................................................................................................................................................................

13

Check the state of the LEDs and display:

The i/xCEM-U and i/xCCM-U corporate LEDs should turn on, then take the
following state: red LED OFF and green LED ON.
For an xCCM-U:
The green PCM/MDA LEDs should be ON.

The SYNC status LEDs should indicate the PCM/MDA synchronization


(green/amber).
The green built-in RX/TX OPTIC LEDs should be ON.
For an iCCM-U:
The green PCM LEDs should be ON.

The green RX/TX OPTIC LEDs should be ON.


The SYNC display should indicate the PCM synchronization.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-26
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the fans rack (48V)

....................................................................................................................................................................................................................................

E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-27
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the pre-cabled 9326 d2U V2 rack

....................................................................................................................................................................................................................................

Replacing the pre-cabled 9326 d2U V2 rack


Carry out the following procedure to replace the 9326 d2U V2 rack.
Intervention time

40 minutes
Tools required

Screwdrivers
Extraction tool
Figure 7-12 9326 d2U V2 front view (with iCCM-U)

Figure 7-13 9326 d2U V2 front view (with xCCM-U)

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-28
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the pre-cabled 9326 d2U V2 rack

....................................................................................................................................................................................................................................

DANGER
Laser hazard
This equipment operates with invisible laser radiation. Laser radiation can cause
considerable injuries to the eyes.
Never look into the end of an exposed fiber or into an open optical connector when the
optical source is switched on. Always observe the laser warning instructions.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.

NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
Procedure
...................................................................................................................................................................................................

Lock the cem object as well as all the objects associated with the Remote Radio devices
connected to the i/xCCM-U at the OMC, by Set Administrative State.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, NN-20500-032.
...................................................................................................................................................................................................

Power down the 9326 d2U V2.


To do this, follow the procedure Powering down a 9326 d2U V2 (p. 6-3).
...................................................................................................................................................................................................

Remove the management sticker located on the lug, on the right hand side of the 9326
d2U V2 rack.

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-29
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the pre-cabled 9326 d2U V2 rack

....................................................................................................................................................................................................................................

Figure 7-14 Location of the management sticker

This removable sticker contains a 6-digit Network IDentifier (NeID) that is used at 9326
d2U V2 connection to the OMC. This sticker must be stored in a safe location since it will
be reused on the new 9326 d2U V2 rack.
...................................................................................................................................................................................................

Undo and remove the upper and lower hooks (if present).

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-30
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the pre-cabled 9326 d2U V2 rack

....................................................................................................................................................................................................................................

...................................................................................................................................................................................................

Remove the i/xCEM(s)-U using the extraction tool.


...................................................................................................................................................................................................

Remove the i/xCCM-U:

Loosen the two screws on the defective i/xCCM-U front panel.


Unplug the i/xCCM-U from its RBP connectors using the extraction tool.
Disconnect the optical fiber(s) from the i/xCCM-U front panel.

Disconnect the digital cable (connector labeled "ALARM") from the i/xCCM-U front
panel.
For an iCCM-U, disconnect the E1/T1 cable (connector labeled "PCM E1/T1") from
the iCCM-U front panel.
For an xCCM-U, disconnect the PCM E1/T1 cable (connector labeled "PCM E1/T1")
and the MDA cable (connector labeled "MDA") from the xCCM-U front panel.
Extract the i/xCCM-U using the extraction tool.

...................................................................................................................................................................................................

Remove the defective 9326 d2U V2 rack.

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-31
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the pre-cabled 9326 d2U V2 rack

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

Put the new 9326 d2U V2 rack in place.


...................................................................................................................................................................................................

Fix the NeID sticker on the right hand side of the RUC, on the lug of the new 9326 d2U
V2 rack.
...................................................................................................................................................................................................

10

Reinsert the i/xCEM(s)-U in the new digital shelf.


...................................................................................................................................................................................................

11

Reinsert the i/xCCM-U in the new digital shelf:

Insert the i/xCCM-U into the slot guides without plugging it on the RBP.
Reconnect the optical fiber(s) on the i/xCCM-U front panel.
Reconnect the digital cable on the i/xCCM-U front panel.
Insert completely the i/xCCM-U into the digital shelf by plugging it into its RBP
connectors.

Tighten the two screws on the i/xCCM-U front panel.

...................................................................................................................................................................................................

12

Put the two hooks in place and secure them.


...................................................................................................................................................................................................

13

Power up the new 9326 d2U V2.


To do this, follow the procedure Powering up a 9326 d2U V2 (p. 6-2)
...................................................................................................................................................................................................

14

Reconnect the following cables:

For an iCCM-U, the PCM E1/T1 cable on the iCCM-U front panel
For an xCCM-U, the PCM E1/T1 cable and the MDA cable on the xCCM-U front
panel

...................................................................................................................................................................................................

15

Unlock from the OMC the objects previously locked through step 1.
...................................................................................................................................................................................................

16

Connect the TIL on the 9326 d2U V2 (on "PORT2" of the iCCM-U, on "PORT1" of the
xCCM-U) to modify the pre-cabled rack inventory parameters.
...................................................................................................................................................................................................

17

Launch the TIL.


...................................................................................................................................................................................................

18

Go to the I&C menu.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-32
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the pre-cabled 9326 d2U V2 rack

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

19

...................................................................................................................................................................................................

20

In the Change I&C parameters tabs, choose the BTS tab.


...................................................................................................................................................................................................

21

The Serialisation number, Manufacturing Date, and Hardware Release fields are
linked with the defective 9326 d2U V2 rack. This information must be updated.

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-33
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the pre-cabled 9326 d2U V2 rack

....................................................................................................................................................................................................................................

...................................................................................................................................................................................................

22

Using the information printed on the pre-cabled rack labels present on the left hand side
of the 9326 d2U V2 spare, fill out the following fields:

Serialisation number
Manufacturing Date

Hardware Release

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-34
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the pre-cabled 9326 d2U V2 rack

....................................................................................................................................................................................................................................

...................................................................................................................................................................................................

23

Click Send to iBTS and wait during the operation. At the end of the operation, the
following message is displayed:

...................................................................................................................................................................................................

24

Go to the Tools menu.

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-35
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the pre-cabled 9326 d2U V2 rack

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

25

...................................................................................................................................................................................................

26

In the Confirm the reset window, click OK.


...................................................................................................................................................................................................

27

In the End of Reset window, click OK.


...................................................................................................................................................................................................

28

Exit the TIL.


...................................................................................................................................................................................................

29

Disconnect the TIL from the 9326 d2U V2.


...................................................................................................................................................................................................

30

Check the state of the LEDs and display:

The i/xCEM-U and i/xCCM-U corporate LEDs should turn on, then take the
following state: red LED OFF and green LED ON.
For an xCCM-U:
The green PCM/MDA LEDs should be ON.

The SYNC status LEDs should indicate the PCM/MDA synchronization


(green/amber).
The green built-in RX/TX OPTIC LEDs should be ON.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-36
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the digital shelf equipment

Replacing the pre-cabled 9326 d2U V2 rack

....................................................................................................................................................................................................................................

For an iCCM-U:
The green PCM LEDs should be ON.

The green RX/TX OPTIC LEDs should be ON.


The SYNC display should indicate the PCM synchronization.

E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-37
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the optional equipment

Overview

....................................................................................................................................................................................................................................

Replacing the optional equipment


Overview
Purpose

This section presents the replacement procedures related to the following items:

External Alarm module


PCM Lightning Protection (LPPCM) module

Contents
Replacing the External Alarm module

7-39

Replacing the LPPCM module

7-41

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-38
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the optional equipment

Replacing the External Alarm module

....................................................................................................................................................................................................................................

Replacing the External Alarm module


Perform the following procedure to replace the External Alarm module.
Intervention time

Ten minutes
Tools required

Screwdriver
Figure 7-15 Front panel of the External Alarm module

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.
Procedure
...................................................................................................................................................................................................

Open the door(s) of the Node B.


...................................................................................................................................................................................................

Locate the External Alarm module, just below the 9326 d2U V2 rack.
...................................................................................................................................................................................................

On the External Alarm module, disconnect the following cables from the front panel
connectors:

The two external alarm cables


The alarm cable that connects the alarm module to the LPPCM module (if exists)
The private alarm bus cable that is connected to the front panel of the RUC module

The ground cable

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-39
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the optional equipment

Replacing the External Alarm module

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

Loosen the four front panel screws.


...................................................................................................................................................................................................

Remove the defective External Alarm module.


...................................................................................................................................................................................................

Insert the new External Alarm module.


...................................................................................................................................................................................................

Tighten the four front panel screws.


...................................................................................................................................................................................................

Reconnect the five cables.


...................................................................................................................................................................................................

Close the door(s) of the Node B.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-40
Use pursuant to applicable agreements
Issue 4.05 May 2010

9326 d2U V2 corrective maintenance procedures


Replacing the optional equipment

Replacing the LPPCM module

....................................................................................................................................................................................................................................

Replacing the LPPCM module


Carry out the following procedure to replace the LPPCM module.
Intervention time

15 minutes
Tools required

Screwdriver
Wrench for hexagonal head (M6 nut)

Figure 7-16 LPPCM module front panel

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
7-41
Issue 4.05 May 2010
Use pursuant to applicable agreements

9326 d2U V2 corrective maintenance procedures


Replacing the optional equipment

Replacing the LPPCM module

....................................................................................................................................................................................................................................

NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
Procedure
...................................................................................................................................................................................................

Power down the 9326 d2U V2.


To do this, follow the procedure Powering down a 9326 d2U V2 (p. 6-3).
...................................................................................................................................................................................................

Locate the LPPCM module, just above the 9326 d2U V2 rack.
...................................................................................................................................................................................................

Disconnect the cables connected on the LPPCM front panel:

The "PCM Out" cable that is connected to the iCCM-U/xCCM-U

The "IN" alarm bus cable that is connected to the External Alarm module
The PCM cable ("PCM In")
The ground cable

...................................................................................................................................................................................................

Loosen the two front panel screws.


...................................................................................................................................................................................................

Remove the defective LPPCM module.


...................................................................................................................................................................................................

Insert the new LPPCM module.


...................................................................................................................................................................................................

Tighten the two front panel screws.


...................................................................................................................................................................................................

Reconnect the four cables.


...................................................................................................................................................................................................

Power up the 9326 d2U V2.


To do this, follow the procedure Powering up a 9326 d2U V2 (p. 6-2).
E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
7-42
Use pursuant to applicable agreements
Issue 4.05 May 2010

Appendix A: Product
conformance statements

Overview
Purpose

This appendix provides the 9326 d2U V2 product conformance statements.


Contents
European regulatory requirement compliance

A-2

North American regulatory requirement compliance

A-4

Compliances for other regions/countries

A-7

Operating conditions

A-8

Cable specifications

A-9

Product labeling

A-10

...................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
A-1
Issue 4.05 May 2010
Use pursuant to applicable agreements

Product conformance statements

European regulatory requirement compliance

....................................................................................................................................................................................................................................

European regulatory requirement compliance


The 9326 d2U V2 falls under the Directive of the European Parliament and of the Council
of December 15th 2004 on the approximation of the laws of the Member States relating to
electromagnetic compatibility 2004/108/EC.
This directive covers essential requirements in the field of:

Electromagnetic compatibility (EMC) protection requirements contained in Directive


2004/108/EC.
This equipment generates, uses, and can radiate radio frequency energy. If not
installed and used in accordance with the instruction manual, it can interfere with
radio communications. However, there is no guarantee that interferences do not occur
in a particular installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment off and on.
The user is encouraged to correct any interference problems.
EMC requirements have been selected to ensure an adequate level of compatibility for
apparatus in residential, commercial, and light industrial environments. Compatibility
levels, however, do not cover extreme cases that can occur in any location, but that
have a low probability of occurrence. In particular, they may not cover cases where a
source of interference that is producing repeated transient or continuous phenomena is
permanently present. This could include, for example, a radar or broadcast site in the
near vicinity. In these cases, it may be necessary to limit the source of interference,
and/or apply special protection to the interfered part.
Note: For operation or maintenance inside Alcatel-Lucent systems, the operator must
always wear the antistatic wrist strap to maintain the integrity of the product.
Effective use of the Radio spectrum allocated to terrestrial/space radio communication
and orbital resources to avoid interference. The routes and standards used to
demonstrate compliance with these requirements are outlined in the following
paragraphs.
Node B EMC
Compliance with essential EMC requirements was demonstrated using ETSI EN
300 386.
Node B safety
Compliance with essential safety requirements was demonstrated using EN
60950-1 as well as IEC 60950-1.

European Union Environmental Directives (EUED)

The 9326 d2U V2 is manufactured according to the following two European Union
Environmental Directives:

Restriction of Hazardous Substances (RoHS), 2002/95/EC.


The RoHS directive restricts the use of lead, mercury, cadmium, hexavalent
chromium, poly-brominated biphenyls (PBB) and poly-brominated diphenyl ethers
(PBDE) in electrical and electronic products. This directive applies to all electrical
and electronic products placed on the European Union (EU) and European Economic
Area (EEA) markets after July 1, 2006, with certain exemptions, including an
exemption for lead solder in network infrastructure equipment.
Waste of Electrical and Electronic Equipment (WEEE), 2002/96/EC.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
A-2
Use pursuant to applicable agreements
Issue 4.05 May 2010

Product conformance statements

European regulatory requirement compliance

....................................................................................................................................................................................................................................

The WEEE directive mandates the necessary treatment of such equipment when it
enters end-of-life. It specifically identifies requirements for recycling, reuse, and
disposal.

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
A-3
Issue 4.05 May 2010
Use pursuant to applicable agreements

Product conformance statements

North American regulatory requirement compliance

....................................................................................................................................................................................................................................

North American regulatory requirement compliance


The 9326 d2U V2 has been qualified according to North American market requirements.
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in
a particular installation.
If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna


Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected

Consult the dealer or an experienced radio/TV technician for help

Node B safety

The 9326 d2U V2 complies with UL60950-1 and CAN/CSA C22.2 No. 60950-1 Safety
Standards.
The CSA mark is applied on the 9326 d2U V2 and demonstrates compliance with both
US and Canadian Standards.
Node B EMC

The 9326 d2U V2 complies with 47CFR Part 15 class A for EMC emission limits.
This Class A digital apparatus complies with Canadian ICES-003.
Node B interconnection compliance

The 9326 d2U V2 complies with Industry Canada IC-CS03 Part II requirements and
meets the applicable Industry Canada technical specifications.
On the core controller printed circuit board is a label that contains a product identifier in
the following format:

IC: 6933C-ICCMU for iCCM-U module

IC: 6933C-XCCMU for xCCM-U module

The 9326 d2U V2 complies with 47 CFR Part 68 of the FCC rules and the requirements
adopted by the ACTA.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
A-4
Use pursuant to applicable agreements
Issue 4.05 May 2010

Product conformance statements

North American regulatory requirement compliance

....................................................................................................................................................................................................................................

On the core controller printed circuit board is a label that contains a product identifier in
the following format:

US: U3EXDNANICCMU for iCCM-U module


US: U3EXDNANXCCMU for xCCM-U module

If requested, the following information must be provided to the telephone company:

ACTA Registered Number: U3E

Facility Interface Code (FIC): 04DU9.BN, 04DU9.DN, 04DU9.1KN, and


04DU9.1SN
Service Order Code (SOC): 6.0F

A FCC part 68 and ACTA compliant cable is provided with the Node B equipment, with
no connector at network interface side. The Node B equipment operates with a 1.544
Mbps digital channel. See Installation Instructions for details.
If the Node B equipment causes harm to the phone network, the telephone company will
notify you in advance that temporary discontinuance of service may be required. But if
advance notice is not practical, the telephone company will notify the customer as soon as
possible. Also, you will be advised of your right to file a complaint with the FCC if you
believe it is necessary.
The telephone company may make changes to its facilities, equipment, operations or
procedures that could affect the operation of the equipment. If this happens the telephone
company will provide advance notice so you can make the necessary modifications to
maintain uninterrupted services.
If trouble is experienced with this equipment 9326 d2U V2, for repair or warranty
information, please contact:
Hernan R. Noguchi Global
Product Compliance Laboratory (GPCL)
Alcatel-Lucent
Phone: 1-732-332-6002 101
Crawfords Corner Road Building
11C, Room 165 Holmdel NJ 07733-3030
If the equipment is causing harm to the telephone network, the telephone company may
request that you disconnect the equipment until the problem is resolved.
All repairs should be handled by authorized Alcatel-Lucent Service Personnel.
Node B data equipment

The following table shows which jacks are associated with which modes of operation.
Operation Mode
Programmable & Test

USOC Jack
RJ45S

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
A-5
Issue 4.05 May 2010
Use pursuant to applicable agreements

Product conformance statements

North American regulatory requirement compliance

....................................................................................................................................................................................................................................

Node B systems

Facility Interface Codes (FIC), Services Order Codes (SOC), USOC Jack Codes, and
Ringer Equivalence Number (REN) are shown in the table below for each port where
applicable.
Port

FIC

SOC

USOC Jack

REN

iCCM-U T1
board

04DU9.BN

6.0F

N/A

N/A

iCCM-U T1
board

04DU9.DN

6.0F

N/A

N/A

iCCM-U T1
board

04DU9.1KN

6.0F

N/A

N/A

iCCM-U T1
board

04DU9.1SN

6.0F

N/A

N/A

iCCM-U T1
board1

04DU9.BN

6.0F

N/A

N/A

iCCM-U T1
board1

04DU9.DN

6.0F

N/A

N/A

iCCM-U T1
board1

04DU9.1KN

6.0F

N/A

N/A

iCCM-U T1
board1

04DU9.1SN

6.0F

N/A

N/A

Note: 1 equipped with MDA 4E1/T1 PCM links

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
A-6
Use pursuant to applicable agreements
Issue 4.05 May 2010

Product conformance statements

Compliances for other regions/countries

....................................................................................................................................................................................................................................

Compliances for other regions/countries


It is impossible to list all the applicable approvals/compliances as they depend on the
markets and products concerned.
Note: Contact your local Alcatel-Lucent representative for more information.

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
A-7
Issue 4.05 May 2010
Use pursuant to applicable agreements

Product conformance statements

Operating conditions

....................................................................................................................................................................................................................................

Operating conditions
The product compliance standards mentioned above are based on the following operating
conditions:

External cables must be of the same type as specified by Alcatel-Lucent.


No modification of any mechanical or electrical characteristics of the product shall be
made.

Any changes or modifications made to the product without written approval from
Alcatel-Lucent releases Alcatel-Lucent from responsibility regarding standards
compliance.

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
A-8
Use pursuant to applicable agreements
Issue 4.05 May 2010

Product conformance statements

Cable specifications

....................................................................................................................................................................................................................................

Cable specifications
Compliance with these standards was verified using cables as specified by
Alcatel-Lucent. The continuing compliance of the product relies upon use of the correct
cabling scheme as well as use of identical type cables as specified by Alcatel-Lucent.
Refer to the installation guides for details on cable specifications.

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
A-9
Issue 4.05 May 2010
Use pursuant to applicable agreements

Product conformance statements

Product labeling

....................................................................................................................................................................................................................................

Product labeling
The label may be located inside or outside the product, provided that the operation and/or
maintenance personnel have the information when working on the product.
Node B labeling for American Countries

To indicate compliance with the CSA and UL Safety requirements, the 9326 d2U V2
bears the following mark in a conspicuous location.

On the main regulatory label, compliance to 47 CFR Part 15 is stated along with:

Manufacturers name
Equipment designation
Nominal voltage operating range and maximum rated current

Compliance to Industry Canada ICES-003 is stated on additional regulatory label.


Compliance to the 47 CFR Part68 and IC CS-03 are stated through additional labels on
the Core Controller Module printed circuit board since certification is performed at
module level (Host Independent submission).
Node B labeling for European Countries

To indicate compliance with the European 2004/108/EC Directive, the 9326 d2U V2
bears the following label in a visible location:

Manufacturers name
Equipment designation
Nominal voltage operating range and maximum rated current

....................................................................................................................................................................................................................................
Alcatel-Lucent Proprietary
NN-20500-204
A-10
Use pursuant to applicable agreements
Issue 4.05 May 2010

Product conformance statements

Product labeling

....................................................................................................................................................................................................................................

Labeling for other regions / countries

Labeling for other regions and countries is performed as appropriate and required by the
local regulatory framework.

....................................................................................................................................................................................................................................
NN-20500-204
Alcatel-Lucent Proprietary
A-11
Issue 4.05 May 2010
Use pursuant to applicable agreements

You might also like