You are on page 1of 58

H

45

TO

H 48 EC U TI EX
29/08/2011 HELFER THOMAS HELFER THOMAS 31/08/2011

ci

ffi

PAQUES DIDIER PAQUES DIDIER

FO

A4

al
31/08/2011 PANAROTTO ELVIO PANAROTTO ELVIO

DEVICE SUMMARY

NOMENCLATURE.APP.CONTROLE

392A8431
DT-1C

IM-2011005753

GRD X

CHENUT BRIGITTE

VALIDE

05-Jan-2012-12:49

IT

SIZE

DWG NO

SH

REV

A4

392A8431
ISO PROJECTION

C
REV DESCRIPTION REVISIONS NAMES

TBFT-TMP-FR-GTE-0060- Rev : 001

DATE 13/10/2009

SIGNATURES

A
EACH SECTION SHALL BE REVISED IN ITS ENTIRETY. ALL SHEETS OF EACH SECTION ARE THE SAME REVISION LEVEL AS INDICATED IN THE REVISION BLOCK

First issue

IM-2010005556 IM-2011005753 (DCI 11019816)

T. Helfer D. Pques P. Janin T. Helfer D. Pques P. Kleinprintz T. Helfer D. Pques E. Panarotto

16/09/2010

26/08/2011

SECTION INDEX 01EN 01FR

NO. OF SHEETS 1 28 28

REV C C C

Attention : Dont modify this document without any update of the database P414. Attention : Ne pas modifier ce document sans mise jour de la base P414.

Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel. Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable. This document, exclusive property of GE Energy Products France SNC is strictly confidential. It must not be communicated, copied or reproduced without our prior written consent. UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MM [INCHES] TOLERANCES ON: 1 [2] PL DECIMALS + 2 [3] PL DECIMALS + ANGLES + FRACTIONS +
DRAWN

First made for : 9171E


DATE

ITEM : 0414

NAMES

T. Helfer
CHECKED

13/10/09 13/10/09 13/10/09

D. Pques
APPROVED

P. Janin

NOMENCLATURE DES APPAREILS DE CONTROLE DIAGRAM. SCHEMA. P.P. DEVICE SUMMARY


SIZE CAGE CODE DWG NO

WEIGHT : 0000 kg

A4
SCALE

392A8431

INDEX

DT-1C

SHEET

1/1
Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4

392A8431

C
REVISIONS

TBFT-TMP-FR-GTE-0060 Rev : 001

Rev A B C

Description First issue - P&ID 0471 : Number change : 227D1412 instead of 219D2887 - P&ID 0462 : characteristics modification of devices 33WN-8, 90WN-1 and VPR62-1 P&ID 0422 : Max. stroke tolerance modification of valve VSR-1.

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

1/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4

392A8431

TBFT-TMP-FR-GTE-0060 Rev : 001

PRESSURE : All pressures are gauge pressure, abs means absolute pressure.

Abbreviations
AA ACF AD AE AMF DEC. DPDT DPG FC FO GF GFV GPL INC. LVDT MLI NC NO Normal OD OD OD OH OHT OL OLV OR PC Safety Slope SPDT SPST WD WF WR

Descriptions
Atomizing Air Control Filter Downstream Pressure Compressor Discharge Air Extraction Air Lube Oil Filter Downstream Pressure Decreasing Double pole, double throw Differential Pressure Gauge Fail safe to close Fail open Gas Fuel Gas Fuel Vent Gas Valve Stem Packaging Leakoff Increasing Linear variable differential transformer Model List Item : four digit code used by General Electric to identify components, assembly, drawings or specifications, example : MLI 0414 for Device Summary Normally closed Normally open Means absolute zero energy level, such as no power, no oil, no speed, no temperature Oil Drain Oil drain above oil tank level Oil drain below oil tank level Control Oil High Pressure Trip Oil High Pressure Lube Oil Lube Oil Event Regulated Lube Oil Piping connecting point Safety Integrity Level (a cross means the device belong to a safety loop related to personnel safety). Do not modify devices or settings of any safety loop. The arrow direction indicates the liquid gravitational drainage due to the slope Single pole, double throw Single pole, single throw Water Drain Water Feed Water Return

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

2/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4

392A8431

C Description

TBFT-TMP-FR-GTE-0060 Rev : 001

Wiring diagram
ACCY AIR AIR DRY CHROM CLEAN CO2 ENCL-G ENCL-LF ENCL-LO ENCL-T ENCL-V ENCL-WI FILT FG-SSOV GAS GAS HEAT GENE IBH LF-AA LF-AA-WI LF-SR LF-TR LF-FD LF-H LF-TPH LF-PH LF-FT-PR LO FG LOAD MIST OIL STEAM TURB TURN-GEAR

The device is in the accessories wiring diagram (MLI 401A) The device is in the cooling fan module wiring diagram (MLI A132) The device is in the air dryer module wiring diagram (MLI 1049) The device is in the chromatograph module wiring diagram (MLI G023) The device is in the cleaning module wiring diagram (MLI E026) The device is in the CO2 fire protection module wiring diagram (MLI A068) The device is in the gas enclosure interface drawing (MLI 1195) The device is in the liquid fuel / atomizing air / water injection module enclosure interface drawing (MLI 1152) The device is in the lube oil / fuel gas module enclosure interface drawing (MLI 1137) The device is in the turbine enclosure interface drawing (MLI 1113) The device is in the ventilation enclosure interface drawing (MLI 1643) The device is in the water injection enclosure interface drawing (MLI 1196) The device is in the air filter wiring diagram (MLI A040) The device is in the fuel gas, SSOV & vent module wiring diagram (MLI G064) The device is in the gas module wiring diagram (MLI 0991 or 401G) The device is in the gas heating and treatment system wiring diagram (MLI G025) The device is in the generator wiring diagram The device is in the bleed heating wiring diagram (MLI A037) The device is in the liquid fuel / atomizing air module wiring diagram (MLI A162) The device is in the liquid fuel / atomizing air / water injection module wiring diagram (MLI A162) The device is in the liquid fuel recirculation skid wiring diagram (MLI 969S) The device is in the liquid fuel treatment skid wiring diagram (MLI E020) The device is in the liquid fuel flow devider wiring diagram (MLI 0613) The device is in the liquid fuel heater wiring diagram (MLI E041) The device is in the liquid fuel transfert pump&heating skid wiring diagram (MLI E047) The device is in the liquid fuel pump&heating skid wiring diagram (MLI A245) The device is in the liquid fuel flow totalizer & pression regulation skid wiring diagram (MLI A246) The device is in the lube oil / fuel gas module wiring diagram (MLI A160) The device is in the load gear wiring diagram (MLI A012) The device is in the mist eliminator outline drawing (MLI A098) The device is in the lube oil wiring diagram (MLI 0990 or 401H) The device is in the steam injection module wiring diagram (MLI A135) The device is in the gas turbine wiring diagram (MLI 401T) The device is in the turning gear wiring diagram (MLI A073)
SIZE CAGE CODE DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

3/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
VAN WASH WI

392A8431

TBFT-TMP-FR-GTE-0060 Rev : 001

The device is in the additive injection vanadium module wiring diagram (MLI E021) The device is in the water washing module wiring diagram (MLI E025) The device is in the water injection module wiring diagram (MLI A035)

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

4/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4

392A8431

C MLI P&ID
0415 0416 0417 0419 0420 0421 0422 0424 0425 0426 0428 0431 0432 0434 0436 0441 0442 0462 0469 0471 0474 0477 0482 0491 0492 0494 0969 G044

TBFT-TMP-FR-GTE-0060 Rev : 001

System Name
Control Devices Turbine System Lube Oil System Cooling and Sealing Air System Instrument Air System Cooling Water System Starting Means System Gas Fuel System Liquid Fuel System Atomizing Air System Fire Protection System PP Station Air System Steam Injection System Inlet Air heating System Hydraulic Supply System Heating and Ventilation System Turbine and Compressor Cleaning System Turbine and Compressor Washing System Water Injection System Compressor Inlet Guide Vanes System Flow Inlet and Exhaust System Gas Detection System Fuel Purge System Gas Fuel Process System Nitrogen Injection System Performance Monitor System Additive Injection Skid System Interconnections lines System Fuel Gas Filtration and Stop Valve

System
CD LO CSA APU CW SM GF LF AA FP AE SI IAR HS HV TCC TCW WI IGV IE GD FPU GFPS NI PM LFAD IL GFF

Reference
227D1199 227D1331 219D2331 N/A 219D2889 205D4866 227D1390 227D1347 227D1078 219D2715 N/A N/A N/A 209D7043 219D2734 227D1308 219D1293 227D1360 219D1732 227D1412 209D7635 219D1141 N/A N/A 214D1258 219D1937 N/A N/A

Rev
A F C D C C E D B

C C A C A A A A B

C B

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

5/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0425 0425 0417 0424 0422 0422 0424 0494 0441 0441 0424

392A8431
Devices 20AA-18 20AB-1 20CB-1 20CF-1 20FGC-1 20FGS-1 20FL-1 20IA-31 20KF 20KF/PB 20PF-100 MLI 918T 0922 1071 0510 0509 0507 0511 E021/E0 48 E026 E026 0961

6
Wiring Diagram TURB ACCY TURB ACCY GAS GAS ACCY VAN CLEAN CLEAN TURB

C
Safety Designation

TBFT-TMP-FR-GTE-0060 Rev : 001

Solenoid valve for VA18-1 control Characteristics : Normal : 1 to 3 open ; 2 closed | 0.035 kW | 125 VDC Solenoid valve for VA22-1 control Characteristics : Normal : 1 to 3 open ; 2 closed | 0.035 kW | 125 VDC Compressor bleed solenoid valve Characteristics : Normal : B to C Open, A closed | 0.04 kW | 125 VDC Fuel pump clutch solenoid Characteristics : Normal : NO | 125 VDC | 0.16 kW (max) Trip solenoid valve for gas control valve (VGC-1) Characteristics : Normal : NO | 0.0156 kW | 125 VDC Fuel gas stop valve solenoid valve Characteristics : Normal : NO | 0.0156 kW | 125 VDC Liquid fuel stop valve solenoid Characteristics : Normal : NC | 0.02 kW | 125 VDC Solenoid valve command the VA99-32 valve Characteristics : Normal : 1 to 2 closed | 12 W | 125 VDC Motor valve cleaning skid Characteristics : 230 VAC | Normal : NC | 50 hz | 0.045 kW Cleaning skid push button Purge fuel liquid solenoid valve Characteristics : Normal : A to P open. B closed | 40 W | 125 VDC Solenoid valve for VA13-1 control Characteristics : Normal : 1 to 3 open ; 2 closed | 0.035 kW | 125 VDC Settings : A needle-valve is installed upstream of 20PG-1 in order to adjust VA13-1 time opening at 30 seconds Solenoid valve for VA13-2 control Characteristics : Normal : 1 to 3 open ; 2 closed | 0.035 kW | 125 VDC Solenoid valve for VA19-1 control Characteristics : Normal : 1 to 3 open ; 2 closed | 0.035 kW | 125 VDC Torque converter fill / drain solenoid valve Characteristics : Normal : NC Solenoid valve for compressor IGV trip system Characteristics : Normal : NO | 0.1 kW | 125 VDC Motor valve off-line compressor water wash Characteristics : 230 VAC | Normal : NC | 50 hz | 0.072 kW Motor valve turbine water wash Characteristics : 230 VAC | Normal : NC | 50 hz | 0.23 kW Motor valve on-line compressor water wash Characteristics : 230 VAC | Normal : NC | 50 hz | 0.072 kW Fuel gas vent solenoid valve Characteristics : Normal : NO | 0.009 kW | 125 VDC Gas fuel purge vent solenoid valve Characteristics : Normal : NO | 0.125 kW | 125 VDC Water injection stop valve solenoid valve Characteristics : Normal : NO | 0.0112 kW | 125 VDC Water injection stop valve solenoid valve (part of VS2-2) Characteristics : Normal : NO | 0.0112 kW | 125 VDC Solenoid valve for fuel check valves cooling water Characteristics : Normal : NO | 0.0112 kW | 125 VDC

0477

20PG-1

0991

GAS

0477 0477 0421 0469 0442 0442 0442 0422 0477 0462 0462 0420

20PG-2 20PL-1 20TU-1 20TV-1 20TW-1 20TW-2 20TW-3 20VG-1 20VG-2 20WN-1 20WN-2 20WN-30

0991 918T 0605 0548 0953 0983 0953 0991 0991 A035 A035 0963

GAS TURB ACCY TURB TURB TURB TURB GAS GAS WI WI TURB

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

6/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0425 0436 0436 0421 0421 0421 0436 0436 0436 0436 0436 0436 0436 0434 0436 0416 0416 0416 0416 0421 0417 0417 0436 0436 0462

392A8431
Devices 23AB-1 23BT-1 23BT-2 23CR-1 23CR-2 23CR-3 23HA-11 23HA-12 23HA-13 23HA-14 23HA-15 23HA-16 23HA-30 23HQ-1 23HT-30 23QA-1 23QT-1 23QT-2 23QV-1A 23TG-1 23TK-1 23TK-2 23VG-1 23VG-2 23WN-1 MLI 1047 1605 1605 0603 0603 0603 1658 1658 1658 1658 1658 1658 1113 0628 1113 1006 0938 0938 A098 0603 1233 1233/A 132 1605 1605 A035

7
Wiring Diagram ACCY ENCL-T ENCL-T ACCY ACCY ACCY ENCL-G ENCL-G ENCL-G ENCL-G ENCL-G ENCL-G ENCL-T ACCY ENCL-T ACCY ACCY ACCY MIST ACCY ACCY ACCY ENCL-T ENCL-T WI

C
Safety Designation Anti-condensation heater for motor 88AB-1 Characteristics : 50 hz | 230 VAC | 0.05 kW Anti-condensation heater for motor 88BT-1 Characteristics : 50 hz | 230 VAC | 0.05 kW Anti-condensation heater for motor 88BT-2 Characteristics : 50 hz | 230 VAC | 0.05 kW Anti-condensation heater for motor 88CR-1 Characteristics : 50 hz | 230 VAC | 0.18 kW Anti-condensation heater for motor 88CR-1 Characteristics : 50 hz | 230 VAC | 0.18 kW Anti-condensation heater for motor 88CR-1 Characteristics : 50 hz | 230 VAC | 0.18 kW Gas compartment heater Characteristics : 50 hz | 400 VAC | 3.9 kW Gas compartment air inlet heater Characteristics : 50 hz | 400 VAC | 15 kW Gas compartment air inlet heater Characteristics : 50 hz | 400 VAC | 15 kW Gas compartment air inlet heater Characteristics : 50 hz | 400 VAC | 15 kW Gas compartment air inlet heater Characteristics : 50 hz | 400 VAC | 15 kW Gas compartment air inlet heater Characteristics : 50 hz | 400 VAC | 15 kW Auxiliaries compartment heater Characteristics : 50 hz | 400 VAC | 15 kW Anti-condensation heater for motor 88HQ-1 Characteristics : 50 hz | 230 VAC | 0.05 kW Turbine compartment heater Characteristics : 50 hz | 400 VAC | 20 kW Anti-condensation heater for motor 88QA-1 Characteristics : 50 hz | 230 VAC | 0.1 kW Immersion heater lube oil tank Characteristics : 50 hz | 400 VAC | 13.0 kW Immersion heater lube oil tank Characteristics : 50 hz | 400 VAC | 13.0 kW Anti-condensation heater for motor 88QV-1A Characteristics : 50 hz | 230 VAC | 0.05 kW Anti-condensation heater for motor 88TG-1 Characteristics : 50 hz | 230 VAC | 0.05 kW Anti-condensation heater for motor 88TK-1 Characteristics : 50 hz | 230 VAC | 0.05 kW Anti-condensation heater for motor 88TK-2 Characteristics : 50 hz | 230 VAC | 0.05 kW Anti-condensation heater for motor 88VG-1 Characteristics : 50 hz | 230 VAC | 0.05 kW Anti-condensation heater for motor 88VG-2 Characteristics : 50 hz | 230 VAC | 0.05 kW Anti-condensation heater for motor 88WN-1 Characteristics : 50 hz | 230 VAC | 0.05 kW SIZE CAGE CODE DWG NO

TBFT-TMP-FR-GTE-0060 Rev : 001

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

7/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0436 0471 0415 0415 0415 0415 0415

392A8431
Devices 23WR-30 27TF-1 28FD-10 28FD-11 28FD-4 28FD-5 30SG-1 MLI 1196 A040 1121 1121 1121 1121 1213

8
Wiring Diagram ENCL-WI FILT TURB TURB TURB TURB TURB

C
Safety Designation Water injection skid enclosure heater Characteristics : 50 hz | 400 VAC | 9 kW GT air filter general alarm dispatching Flame detector combustion chamber n10 Flame detector combustion chamber n11 Flame detector combustion chamber n4 Flame detector combustion chamber n5 Ignition transformer alarm relay Characteristics : Normal : NO GT compartment ventilation damper limit switch Characteristics : Normal : NO Settings : Flap closed : limit switch activated, contact closed GT compartment ventilation damper limit switch Characteristics : Normal : NO Settings : Flap closed : limit switch activated, contact closed

TBFT-TMP-FR-GTE-0060 Rev : 001

0436

33BT-1

1605

ENCL-T

0436

33BT-2

1605

ENCL-T

0417

33CB-1

1022

TURB

Bleed valve limit switch (11th stage) Characteristics : Normal : NO Settings : Valve opened : limit switch activated, contact closed Bleed valve limit switch (11th stage) Characteristics : Normal : NO Settings : Valve opened : limit switch activated, contact closed Bleed valve limit switch (11th stage) Characteristics : Normal : NO Settings : Valve opened : limit switch activated, contact closed Bleed valve limit switch (11th stage) Characteristics : Normal : NO Settings : Valve opened : limit switch activated, contact closed Auxiliaries compartment door limit switch Characteristics : Normal : NO Settings : Door closed : limit switch activated, contact closed Load compartment door limit switch gas compartment Characteristics : Normal : NO Settings : Door closed : limit switch activated, contact closed Load compartment door limit switch gas compartment Characteristics : Normal : NO Settings : Door closed : limit switch activated, contact closed Gas compartment door limit switch Characteristics : Normal : NO Settings : Door closed : limit switch activated, contact closed Gas compartment door limit switch Characteristics : Normal : NO Settings : Door closed : limit switch activated, contact closed Auxiliaries compartment door limit switch Characteristics : Normal : NO Settings : Door closed : limit switch activated, contact closed Turbine compartment door limit switch Characteristics : Normal : NO Settings : Door closed : limit switch activated, contact closed Turbine compartment door limit switch Characteristics : Normal : NO Settings : Door closed : limit switch activated, contact closed

0417

33CB-2

1022

TURB

0417

33CB-3

1022

TURB

0417

33CB-4

1022

TURB

0436

33DT-1

1605

ENCL-T

0436

33DT-11

1658

ENCL-G

0436

33DT-12

1658

ENCL-G

0436

33DT-13

1658

ENCL-G

0436

33DT-14

1658

ENCL-G

0436

33DT-2

1605

ENCL-T

0436

33DT-3

1605

ENCL-T

0436

33DT-4

1605

ENCL-T

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

8/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0424

392A8431
Devices MLI

9
Wiring Diagram ACCY

C
Safety Designation Liquid fuel stop valve limit switch Characteristics : Normal : NO Settings : Valve closed : limit switch activated, contact closed

TBFT-TMP-FR-GTE-0060 Rev : 001

33FL-1

0511

0436

33JS-1

1659

ENCL-WI

Water injection skid enclosure : ventilation damper limit switch Characteristics : Normal : NO Settings : Flap closed : limit switch activated, contact closed Water injection skid enclosure : ventilation damper limit switch Characteristics : Normal : NO Settings : Flap closed : limit switch activated, contact closed Cleaning skid valve limit switch Characteristics : Normal : NO Settings : Valve closed : limit switch activated, contact closed Cleaning skid valve limit switch Characteristics : Normal : NO Settings : Valve opened : limit switch activated, contact closed Purge fuel liquid valve limit switch VP-1 Characteristics : Normal : NO Settings : Valve closed : limit switch activated, contact closed VA13-1 close position limit switch Characteristics : Normal : NO Settings : Valve closed : limit switch activated, contact closed VA13-1 open position limit switch Characteristics : Normal : NO Settings : Valve opened : limit switch activated, contact closed VA13-2 close position limit switch Characteristics : Normal : NO Settings : Valve closed : limit switch activated, contact closed VA13-2 open position limit switch Characteristics : Normal : NO Settings : Valve opened : limit switch activated, contact closed Torque converter solenoid valve limit switch Characteristics : Normal : NO Settings : 20TU-1 de-energized : switch activated, contact closed False start drain valve limit switch Characteristics : Normal : NO Settings : Valve opened : limit switch activated, contact closed Torque converter low torque limit switch Characteristics : Normal : NO, switch closed for IGV closed or max torque Settings : Setup at 3 tr of handwheel (full scale 0-242 tr) Torque converter high torque limit switch Characteristics : Normal : NO, switch closed for IGV closed or max torque Settings : Setup at 242 tr of handwheel (full scale 0-242 tr) Load compartment ventilation damper limit switch Characteristics : Normal : NO Settings : Flap closed : limit switch activated, contact closed Gas system vent valve limit switch Characteristics : Normal : NO Settings : Valve closed : limit switch activated, contact closed Load compartment ventilation damper limit switch Characteristics : Normal : NO Settings : Flap closed : limit switch activated, contact closed Gas compartment ventilation damper limit switch Characteristics : Normal : NO Settings : Flap closed : limit switch activated, contact closed

0436

33JS-2

1659

ENCL-WI

0441

33KF-1

E026

CLEAN

0441

33KF-2

E026

CLEAN

0424

33PF-1

0961

TURB

0477

33PG-1

0991

GAS

0477

33PG-2

0991

GAS

0477

33PG-3

0991

GAS

0477

33PG-4

0991

GAS

0421

33TC-1

0605

ACCY

0442

33TFD-1

1026

TURB

0421

33TM-5

0605

ACCY

0421

33TM-6

0605

ACCY

0436

33VG-1

1605

ENCL-T

0422

33VG-11

0991

GAS

0436

33VG-2

1605

ENCL-T

0436

33VL-1

1658

ENCL-G

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

9/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0436

392A8431
Devices MLI

10
Wiring Diagram ENCL-G

C
Safety Designation Gas compartment ventilation damper limit switch Characteristics : Normal : NO Settings : Flap closed : limit switch activated, contact closed

TBFT-TMP-FR-GTE-0060 Rev : 001

33VL-2

1658

0462

33WN-1

A035

WI

Water injection control valve limit switch (part of VC4-1) Characteristics : Normal : NO Settings : Valve full opened : limit switch activated, contact closed Water injection control valve limit switch (part of VC4-1) Characteristics : Normal : NO Settings : Valve full closed : limit switch activated, contact closed Water injection stop valve limit switch (part of VS2-1) Characteristics : Normal : NO Settings : Valve full opened : limit switch activated, contact closed Water injection stop valve limit switch (part of VS2-1) Characteristics : Normal : NO Settings : Valve full closed : limit switch activated, contact closed Water injection stop valve limit switch (part of VS2-2) Characteristics : Normal : NO Settings : Valve full opened : limit switch activated, contact closed Water injection stop valve limit switch (part of VS2-2) Characteristics : Normal : NO Settings : Valve full closed : limit switch activated, contact closed Vibration sensor Characteristics : For 25.4 mm/s (1 in/s), 150 7.5 mV peak Vibration sensor Characteristics : For 25.4 mm/s (1 in/s), 150 7.5 mV peak Vibration sensor Characteristics : For 25.4 mm/s (1 in/s), 150 7.5 mV peak Vibration sensor Characteristics : For 25.4 mm/s (1 in/s), 150 7.5 mV peak Vibration sensor Characteristics : For 25.4 mm/s (1 in/s), 150 7.5 mV peak Compressor casing accelerometer Characteristics : 1.02 mV/m/s2 (10 mV/g) 5% 3.94 mV/mm/s 5% Vibration sensor Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil) Settings : Gap : 1.4 0.05 mm (0.055 0.002 in) Vibration sensor Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil) Settings : Gap : 1.4 0.05 mm (0.055 0.002 in) Vibration sensor Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil) Settings : Gap : 1.4 0.05 mm (0.055 0.002 in) Vibration sensor Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil) Settings : Gap : 1.4 0.05 mm (0.055 0.002 in) Vibration sensor Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil) Settings : Gap : 1.4 0.05 mm (0.055 0.002 in) Vibration sensor Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil) Settings : Gap : 1.4 0.05 mm (0.055 0.002 in)

0462

33WN-2

A035

WI

0462

33WN-3

A035

WI

0462

33WN-4

A035

WI

0462

33WN-7

A035

WI

0462

33WN-8

A035

WI

0415 0415 0415 0415 0415

39V-1A 39V-1B 39V-2A 39V-3A 39V-3B

1218 1218 1218 1218 1218

TURB TURB TURB TURB TURB

0415

39V-CC

1218

TURB

0415

39VS-11

235A

TURB

0415

39VS-12

235A

TURB

0415

39VS-21

235B

TURB

0415

39VS-22

235B

TURB

0415

39VS-23

235B

TURB

0415

39VS-24

235B

TURB

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

10/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4
MLI PID 0415

392A8431
Devices MLI

11
Wiring Diagram TURB

C
Safety Designation Vibration sensor Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil) Settings : Gap : 1.4 0.05 mm (0.055 0.002 in) Vibration sensor Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil) Settings : Gap : 1.4 0.05 mm (0.055 0.002 in) Break glass unit auxiliaries compartment access door Characteristics : Normal : NO Break glass unit GT compartment access door Characteristics : Normal : NO Break glass unit auxiliaries compartment access door Characteristics : Normal : NO Break glass unit GT compartment access door Characteristics : Normal : NO Break glass unit load compartment access door Characteristics : Normal : NO Break glass unit gas compartment access door Characteristics : Normal : NO Break glass unit gas compartment access door Characteristics : Normal : NO Off-line water wash push button Characteristics : Normal : NO Turbine water wash push button Characteristics : Normal : NO Thermostatic fire detector auxiliaries compartment Characteristics : Normal : NO Settings : Closed : 163 14C (325 25F) Thermostatic fire detector auxiliaries compartment Characteristics : Normal : NO Settings : Closed : 163 14C (325 25F) Thermostatic fire detector auxiliaries compartment Characteristics : Normal : NO Settings : Closed : 163 14C (325 25F) Thermostatic fire detector auxiliaries compartment Characteristics : Normal : NO Settings : Closed : 163 14C (325 25F) Thermostatic fire detector auxiliaries compartment Characteristics : Normal : NO Settings : Closed : 163 14C (325 25F) Thermostatic fire detector auxiliaries compartment Characteristics : Normal : NO Settings : Closed : 163 14C (325 25F) Thermostatic fire detector auxiliaries compartment Characteristics : Normal : NO Settings : Closed : 163 14C (325 25F) Thermostatic fire detector auxiliaries compartment Characteristics : Normal : NO Settings : Closed : 163 14C (325 25F) Thermostatic fire detector auxiliaries compartment Characteristics : Normal : NO Settings : Closed : 163 14C (325 25F)

TBFT-TMP-FR-GTE-0060 Rev : 001

39VS-31

235C

0415

39VS-32

235C

TURB

0426 0426 0426 0426 0426 0426 0426 0442 0442

43CP-1 43CP-2 43CP-3 43CP-4 43CP-5 43CP-6 43CP-7 43TW-1/PB 43TW-2/PB

1113 1113 1153 1113 1113 1195 1195 1105 1105

ENCL-T ENCL-T ENCL-T ENCL-T ENCL-T ENCL-G ENCL-G TURB TURB

0426

45FA-10A

1113

ENCL-T

0426

45FA-10B

1113

ENCL-T

0426

45FA-11A

1113

ENCL-T

0426

45FA-11B

1113

ENCL-T

0426

45FA-12A

1113

ENCL-T

0426

45FA-12B

1113

ENCL-T

0426

45FA-13A

1113

ENCL-T

0426

45FA-13B

1113

ENCL-T

0426

45FA-1A

1104

ACCY

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

11/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4
MLI PID 0426

392A8431
Devices MLI

12
Wiring Diagram ACCY

C
Safety Designation Thermostatic fire detector auxiliaries compartment Characteristics : Normal : NO Settings : Closed : 163 14C (325 25F) Thermostatic fire detector auxiliaries compartment Characteristics : Normal : NO Settings : Closed : 163 14C (325 25F) Thermostatic fire detector auxiliaries compartment Characteristics : Normal : NO Settings : Closed : 163 14C (325 25F) Thermostatic fire detector gas compartment Characteristics : Normal : NO Settings : Closed : 163 14C (325 25F) Thermostatic fire detector gas compartment Characteristics : Normal : NO Settings : Closed : 163 14C (325 25F) Thermostatic fire detector gas compartment Characteristics : Normal : NO Settings : Closed : 163 14C (325 25F) Thermostatic fire detector gas compartment Characteristics : Normal : NO Settings : Closed : 163 14C (325 25F) Thermostatic fire detector GT compartment Characteristics : Normal : NO Settings : Closed : 316 14C (600 25F) Thermostatic fire detector GT compartment Characteristics : Normal : NO Settings : Closed : 316 14C (600 25F) Thermostatic fire detector GT compartment Characteristics : Normal : NO Settings : Closed : 316 14C (600 25F) Thermostatic fire detector GT compartment Characteristics : Normal : NO Settings : Closed : 316 14C (600 25F) Thermostatic fire detector GT compartment Characteristics : Normal : NO Settings : Closed : 316 14C (600 25F) Thermostatic fire detector GT compartment Characteristics : Normal : NO Settings : Closed : 316 14C (600 25F) Thermostatic fire detector load compartment Characteristics : Normal : NO Settings : Closed : 385 14C (725 25F) Thermostatic fire detector load compartment Characteristics : Normal : NO Settings : Closed : 385 14C (725 25F) Thermostatic fire detector load compartment Characteristics : Normal : NO Settings : Closed : 316 14C (600 25F) Thermostatic fire detector load compartment Characteristics : Normal : NO Settings : Closed : 316 14C (600 25F) Gas detector gas module compartment ventilation duct Characteristics : Range : 0 - 20% LEL

TBFT-TMP-FR-GTE-0060 Rev : 001

45FA-1B

1104

0426

45FA-2A

1104

ACCY

0426

45FA-2B

1104

ACCY

0426

45FA-6A

0991

GAS

0426

45FA-6B

0991

GAS

0426

45FA-7A

0991

GAS

0426

45FA-7B

0991

GAS

0426

45FT-1A

1103

TURB

0426

45FT-1B

1103

TURB

0426

45FT-2A

1154

TURB

0426

45FT-2B

1154

TURB

0426

45FT-3A

1154

TURB

0426

45FT-3B

1154

TURB

0426

45FT-8A

1160

TURB

0426

45FT-8B

1160

TURB

0426

45FT-9A

1160

TURB

0426

45FT-9B

1160

TURB

0474

45HA-4

1658

ENCL-G

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

12/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4
MLI PID 0474 0474 0474 0474 0474 0474 0474 0474

392A8431
Devices 45HA-5 45HA-6 45HT-1 45HT-2 45HT-3 45HT-4 45HT-5 45HT-6 MLI 1658 1658 1113 1113 1113 1605 1605 1605

13
Wiring Diagram ENCL-G ENCL-G TURB TURB TURB ENCL-T ENCL-T ENCL-T

C
Safety Designation Gas detector gas module compartment ventilation duct Characteristics : Range : 0 - 20% LEL Gas detector gas module compartment ventilation duct Characteristics : Range : 0 - 20% LEL Gas detector turbine compartment Characteristics : Range : 0 - 20% LEL Gas detector turbine compartment Characteristics : Range : 0 - 20% LEL Gas detector turbine compartment Characteristics : Range : 0 - 20% LEL

TBFT-TMP-FR-GTE-0060 Rev : 001

Gas detector turbine compartment turbine compartment ventilation duct Characteristics : Range : 0 - 20% LEL Gas detector turbine compartment ventilation duct Characteristics : Range : 0 - 20% LEL Gas detector turbine compartment ventilation duct Characteristics : Range : 0 - 20% LEL Security thermostat gas compartment heater Characteristics : Normal : NO Settings : Closed at 100 +0/-16C (212 +0/-61F) Emergency stop button located at auxiliary compartment outside GT compartment Characteristics : Normal : NC Emergency stop button located at auxiliary compartment outside GT compartment Characteristics : Normal : NC Pressure switch of the air circuit Characteristics : Normal : NC Settings : Increase open at : 3 0.25 bar (43.5 4 psi) GT compressed air inlet filter low pressure switch Characteristics : Normal : NO Settings : Not adjustable : increase close at : 6 0.5 bar (87 7.25 psi) | Decrease open at : 5.5 0.5 bar (79.77 7.25 psi) Gas fuel pressure switch Characteristics : Normal : NC Settings : Decrease close at : 1.03 0.05 bar (15.0 0.75 psi) | Not adjustable : increase open at : 2.41 0.05 bar (35.0 0.75 psi) Gas fuel pressure switch Characteristics : Normal : NC Settings : Decrease close at : 1.03 0.05 bar (15.0 0.75 psi) | Not adjustable : increase open at : 2.41 0.05 bar (35.0 0.75 psi) Liquid fuel pressure switch Characteristics : Normal : NO Settings : Not adjustable : increase closed at : 2.75 0.14 bar (40 2 psi) | Decrease open at : 2.41 0.07 bar (35 1 psi) Hydraulic filter differential pressure alarm Characteristics : Normal : NC Settings : Not adjustable : decrease close at : 2.75 1.03 bar (40 15 psi) | Increase open at : 4.13 0.2 bar (60 3 psi)

0436

49HA-12

1658

ENCL-G

0426 0426

5E-10 5E-11

1113 1113

ENCL-T ENCL-T

0494

63AF-31

E021/E0 48

VAN

0471

63CA-1

A040

FILT

0422

63FG-1

0991

GAS

0422

63FG-2

0991

GAS

0424

63FL-2

0992

ACCY

0434

63HF-1

0926

ACCY

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

13/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4
MLI PID

392A8431
Devices MLI

14
Wiring Diagram

C
Safety Designation

TBFT-TMP-FR-GTE-0060 Rev : 001

0434

63HQ-1

0926

ACCY

Low hydraulic supply pressure auxiliary hydraulic pump start Characteristics : Normal : NO Settings : Not adjustable : increase close at : 100 3.1 bar (1450 45 psi) | Decrease open at : 93 1.7 bar (1350 25 psi) Cleaning skid pressure switch Characteristics : Normal : NC Settings : Increase open at : 1 0.1 bar (14.5 1.5 psi) Fuel filter differential pressure alarm Characteristics : Normal : NC Settings : Not adjustable : decrease close at : 1.1 0.07 bar (16 1 psi) | Increase open at : 1.3 0.07 bar (19 1 psi) Pressure switch on VA13-1 & VA13-2 intervalves space Characteristics : Normal : NC Settings : Not adjustable : decrease close at : 3.17 0.21 bar (46 3 psi) | Increase open at : 3.45 0.14 bar (50 2 psi) Pressure switch on liquid fuel purge air Characteristics : Normal : NO Settings : Not adjustable : increase close at : 6 0.3 bar (87 4 psi) | Decrease open at : 4.6 0.3 bar (67 4 psi) Low lube oil pressure alarm Characteristics : Normal : NO Settings : Not adjustable : increase close at : 3.1 0.14 bar (45 2 psi) | Decrease open at : 2.8 0.07 bar (40.6 1 psi) Main lube oil filter differential pressure switch Characteristics : Normal : NC Settings : Not adjustable : decrease close at : 0.9 0.2 bar (13 3 psi) | Increase open at : 1.03 0.068 bar (15 1 psi) Main lube oil filter differential pressure switch Characteristics : Normal : NC Settings : Not adjustable : decrease close at : 0.9 0.2 bar (13 3 psi) | Increase open at : 1.03 0.068 bar (15 1 psi) Torque converter filter differential pressure Characteristics : Normal : NC Settings : Increase open at : 1.5 0.2 bar (21.75 3 psi) Generator bearing low lube oil pressure Characteristics : Normal : NO Settings : Not adjustable : increase close at : 0.62 0.035 bar (9 0.5 psi) | Decrease open at : 0.55 0.021 bar (8 0.3 psi) Differential pressure switch between air inlet and hoods Characteristics : Normal : NC Settings : Increase open at : 3 0.2 mbar (0.04 0.003 psi) Differential pressure switch between air inlet and hoods Characteristics : Normal : NC Settings : Increase open at : 3 0.2 mbar (0.04 0.003 psi) GT inlet air system differential pressure switch Characteristics : Normal : NC Settings : Increase open at : 21 0.5 mbar (0.3 0.007 psi)

0441

63KJ

E026

CLEAN

0424

63LF-7

0992

ACCY

0477

63PG-1

0991

GAS

0477

63PL-21

918T

TURB

0416

63QA-2

0926

ACCY

0416

63QQ-21

0940

ACCY

0416

63QQ-22

0940

ACCY

0416

63QQ-8

0916

ACCY

0416

63QT-2A

ALT.

GENE

0471

63TF-10A

A040

FILT

0471

63TF-10B

A040

FILT

0471

63TF-2A

A040

FILT

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

14/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4
MLI PID

392A8431
Devices MLI

15
Wiring Diagram

C
Safety Designation GT inlet air system differential pressure switch Characteristics : Normal : NC Settings : Increase open at : 21 0.5 mbar (0.3 0.007 psi) Turbine exhaust frame cooling pressure switch Characteristics : Normal : NO Settings : Closed above 381 19 mm H2O (15 0.75 in H2O) Turbine exhaust frame cooling pressure switch Characteristics : Normal : NO Settings : Closed above 381 19 mm H2O (15 0.75 in H2O)

TBFT-TMP-FR-GTE-0060 Rev : 001

0471

63TF-2B

A040

FILT

0417

63TK-1

A053/A 132

ACCY

0417

63TK-2

A053/A 132

ACCY

0462

63WN-1

A035

WI

Water injection pressure switch Characteristics : Normal : NC Settings : Open on decreasing pressure / atm : -0.270 0.01 bar (-3.9 0.14 psi) Water injection pressure switch Characteristics : Normal : NO Settings : Open on decreasing pressure : 25 bar (363 psi) Water injection differential pressure switch on water injection pump filter Characteristics : Normal : NC Settings : Open on increasing differential pressure : 1.03 bar 0.1 bar (15 1 psi) Liquid fuel pump (by pass valve) servo valve Gas control valve servo valve (VGC-1) Level switch in the tank 501BA Characteristics : Normal : NO Settings : Opening on low level Level switch in the auxiliary tank Characteristics : Normal : NO Settings : Opening on low level Fuel leakage detection pot level switch Characteristics : Normal : NC Settings : Opening on high level Fuel leakage detection pot level switch Characteristics : Normal : NC Settings : Opening on high-high level Fuel leakage detection pot level switch Characteristics : Normal : NC Settings : Opening on high-high level High level lube oil tank Characteristics : Normal : NC Settings : Increase open on high level. See lube oil schematic MLI 416 for setting Low level lube oil tank Characteristics : Normal : NO Settings : Decrease open on low level. See lube oil schematic MLI 416 for setting Flow divider magnetic pickup-speed Settings : Gap : 0.23 0.025 mm (0.009 0.001 in) Flow divider magnetic pickup-speed Settings : Gap : 0.23 0.025 mm (0.009 0.001 in) Flow divider magnetic pickup-speed Settings : Gap : 0.23 0.025 mm (0.009 0.001 in) Speed sensor Settings : Gap : 1.27 0.127 mm (0.05 0.005 in)

0462

63WN-2

A035

WI

0462 0424 0422 0494

63WN-3 65FP 65GC-1 71FA-31

A035 0533 0509 E021/E0 48 E021/E0 48

WI ACCY GAS VAN

0494

71FA-32

VAN

0424

71FF-4

969L

TURB

0424

71FF-5

969L

TURB

0424

71FF-6

969L

TURB

0416

71QH-1

1038

ACCY

0416

71QL-1

1038

ACCY

0424 0424 0424 0415

77FD-1 77FD-2 77FD-3 77HT-1

0910 0910 0910 0546

ACCY ACCY ACCY TURB

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

15/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4
MLI PID 0415 0415 0415 0415 0415

392A8431
Devices 77HT-2 77HT-3 77NH-1 77NH-2 77NH-3 MLI 0546 0546 0546 0546 0546

16
Wiring Diagram TURB TURB TURB TURB TURB

C
Safety Designation Speed sensor Settings : Gap : 1.27 0.127 mm (0.05 0.005 in) Speed sensor Settings : Gap : 1.27 0.127 mm (0.05 0.005 in) Speed sensor Settings : Gap : 1.27 0.127 mm (0.05 0.005 in) Speed sensor Settings : Gap : 1.27 0.127 mm (0.05 0.005 in) Speed sensor Settings : Gap : 1.27 0.127 mm (0.05 0.005 in) Keyphasor, shaft end drive turbine side Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil) Settings : Gap : 1.4 0.05 mm (0.055 0.002 in) Atomizing air booster motor Characteristics : 15 kW | 3000 rpm | 27.5A | 50 hz | 400 VAC Cooling air fan motor - acoustical enclosure GT compartment Characteristics : 37 kW | - rpm | 50 hz | 400 VAC Cooling air fan motor - acoustic enclosure GT compartment Characteristics : 37 kW | - rpm | 50 hz | 400 VAC Electrical cranking motor Characteristics : 1000 kW | 3000 rpm | 50 hz | 6.6 kV Electric motor of PFA-30 pump Characteristics : 0.46 kW | 1500 rpm | 50 hz | 230 VAC Electric motor of PFA-31 pump Characteristics : 0.37 kW | 1380 rpm | 50 hz | 400 VAC Electric motor of PFA-32 pump Characteristics : 0.37 kW | 1380 rpm | 50 hz | 400 VAC Flow divider starting motor Characteristics : 0.37 kW | 1400 rpm | 50 hz | 400 VAC Auxiliary hydraulic supply pump motor Characteristics : 15 kW | 1500 rpm | 28.2A | 50 hz | 400 VAC Water injection skid enclosure cooling air fan motor Characteristics : 0.37 kW | 1500 rpm | 50 hz | 400 VAC Cooling air fan motor water injection skid enclosure Characteristics : 0.37 kW | 1500 rpm | 50 hz | 400 VAC Auxiliary lube oil pump motor Characteristics : 90 kW | 3000 rpm | 149,5A | 50 hz | 400 VAC Emergency lube oil pump motor Characteristics : 9 kW | 1750 rpm | 89A | 125 VDC Lube oil mist eliminator motor Characteristics : 18.5 kW | 3000 rpm | 32.8A | 50 hz | 400 VAC Turning gear electrical motor Characteristics : 30 kW | 750 rpm | 50 hz | 400 VAC Turbine exhaust frame cooling blower & motor Characteristics : 45 kW | 3000 rpm | 79A | 50 hz | 400 VAC Turbine exhaust frame cooling blower & motor Characteristics : 45 kW | 3000 rpm | 79A | 50 hz | 400 VAC Torque adjuster drive motor Characteristics : 1.5 kW | 3000 rpm | 50 hz | 400 VAC

TBFT-TMP-FR-GTE-0060 Rev : 001

0415

77RP-11

235A

TURB

0425 0436 0436 0421 0494 0494 0494 0424 0434 0436 0436 0416 0416 0416 0421 0417 0417 0421

88AB-1 88BT-1 88BT-2 88CR-1 88FA-30 88FA-31 88FA-32 88FM 88HQ-1 88JS-1 88JS-2 88QA-1 88QE-1 88QV-1A 88TG-1 88TK-1 88TK-2 88TM-1

1047 1605 1605 0603 E021/E0 48 E021/E0 48 E021/E0 48 0613 0628 1659 1659 1006 1007 A098 0538 1233/A 132 1233/A 132 0605

ACCY ENCL-T ENCL-T ACCY VAN VAN VAN ACCY ACCY ENCL-WI ENCL-WI ACCY ACCY MIST ACCY ACCY ACCY ACCY

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

16/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4
MLI PID 0436 0436 0436 0436 0462 0422 0469

392A8431
Devices 88VG-1 88VG-2 88VL-1 88VL-2 88WN-1 90SR-1 90TV-1 MLI 1605 1605 1658 1658 A035 0507 0548

17
Wiring Diagram ENCL-T ENCL-T ENCL-G ENCL-G WI GAS TURB

C
Safety Designation Cooling air fan motor acoustic enclosure load compartment Characteristics : 18.5 kW | 1500 rpm | 50 hz | 400 VAC Cooling air fan motor acoustic enclosure load compartment Characteristics : 18.5 kW | 1500 rpm | 50 hz | 400 VAC Cooling air fan motor gas module acoustic enclosure Characteristics : 4 kW | 1500 rpm | 50 hz | 400 VAC Cooling air fan motor gas module acoustic enclosure Characteristics : 4 kW | 1500 rpm | 50 hz | 400 VAC Water injection pump motor Characteristics : 55 kW | 3000 rpm | 92.5 A | 50 hz | 400 VAC Gas speed ratio/stop valve servo valve Servovalve, compressor IGV actuator Electro-pneumatic converter Settings : 04 0.20 mA for 0 bar (0 psi) 20 0.20 mA for 2.6 bar (37.7 psi)

TBFT-TMP-FR-GTE-0060 Rev : 001

0462

90WN-1

A035

WI

0436

95BT-1

1605

ENCL-T

Air flow control (anemometer) for turbine enclosure Characteristics : 04 - 20 mA for 0.5 - 30 m/s Settings : fan not running, 0% air flow : 4 -0/+1 mA fan running and doors closed : x1 mA, adjust the speedtronic constant software at a value equivalent to { [60% * (x1 - 4) ] + 4 mA } Air flow control (anemometer) for turbine enclosure Characteristics : 04 - 20 mA for 0.5 - 30 m/s Settings : fan not running, 0% air flow : 4 -0/+1 mA fan running and doors closed : x1 mA, adjust the speedtronic constant software at a value equivalent to { [60% * (x1 - 4) ] + 4 mA } Air flow control (anemometer) for turbine enclosure Characteristics : 04 - 20 mA for 0.5 - 30 m/s Settings : fan not running, 0% air flow : 4 -0/+1 mA fan running and doors closed : x1 mA, adjust the speedtronic constant software at a value equivalent to { [60% * (x1 - 4) ] + 4 mA } Ignition transformer for 95SP-13 Characteristics : 0.15 kVA | 50 hz | 15 kV | 230 VAC Ignition transformer for 95SP-14 Characteristics : 0.15 kVA | 50 hz | 15 kV | 230 VAC Spark plug for combustion chamber n13 Spark plug for combustion chamber n14 Air flow control (anemometer) for gas skid enclosure Characteristics : 04 - 20 mA for 0.5 - 30 m/s Settings : fan not running, 0% air flow : 4 -0/+1 mA fan running and doors closed : x1 mA, adjust the speedtronic constant software at a value equivalent to { [60% * (x1 - 4) ] + 4 mA } Air flow control (anemometer) for gas skid enclosure Characteristics : 04 - 20 mA for 0.5 - 30 m/s Settings : fan not running, 0% air flow : 4 -0/+1 mA fan running and doors closed : x1 mA, adjust the speedtronic constant software at a value equivalent to { [60% * (x1 - 4) ] + 4 mA } Air flow control (anemometer) for gas skid enclosure Characteristics : 04 - 20 mA for 0.5 - 30 m/s Settings : fan not running, 0% air flow : 4 -0/+1 mA fan running and doors closed : x1 mA, adjust the speedtronic constant software at a value equivalent to { [60% * (x1 - 4) ] + 4 mA }

0436

95BT-2

1605

ENCL-T

0436

95BT-3

1605

ENCL-T

0415 0415 0415 0415

95SG-13 95SG-14 95SP-13 95SP-14

1213 1213 1214 1214

TURB TURB TURB TURB

0436

95VL-1

1658

ENCL-G

0436

95VL-2

1658

ENCL-G

0436

95VL-3

1658

ENCL-G

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

17/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4
MLI PID

392A8431
Devices MLI

18
Wiring Diagram

C
Safety Designation Atomizing air manifold pressure transmitter Settings : 04 0,05 mA for -1 bar (-14.5 psi) 20 0,1 mA for 35 bar (507.6 psi) Atomizing air manifold pressure transmitter Settings : 04 0,05 mA for -1 bar (-14.5 psi) 20 0,1 mA for 35 bar (507.6 psi) Atomizing air manifold pressure transmitter Settings : 04 0,05 mA for -1 bar (-14.5 psi) 20 0,1 mA for 35 bar (507.6 psi)

TBFT-TMP-FR-GTE-0060 Rev : 001

0425

96AA-4A

557T

TURB

0425

96AA-4B

557T

TURB

0425

96AA-4C

557T

TURB

0425

96AD-1

0926

ACCY

Atomizing air main compressor differential pressure transmitter Settings : 04 0.02 mA for 0 bar (0 psi) 20 0.1 mA for 6 bar (87 psi) Pressure transmitter Settings : 04 0.02 mA for 0.745 bar abs (22 in of Hg) 20 0.10 mA for 1.250 bar abs (36.9 in of Hg) Pressure transmitter Settings : 04 0.02 mA for 0.745 bar abs (22 in of Hg) 20 0.10 mA for 1.250 bar abs (36.9 in of Hg) Pressure transmitter Settings : 04 0.02 mA for 0.745 bar abs (22 in of Hg) 20 0.10 mA for 1.250 bar abs (36.9 in of Hg) Differential pressure transmitter between the air inlet of GT and the bell of GT intake Settings : 04 0.02 mA for 0.000 bar (0.000 in of H2O) 20 0.10 mA for 0.345 bar (138.5 in of H2O) Compressor discharge pressure transmitter Settings : 04 0.05 mA for 0 bar (0 psi) 20 0.05 mA for 21 bar (304.5 psi) Compressor discharge pressure transmitter Settings : 04 0.05 mA for 0 bar (0 psi) 20 0.05 mA for 21 bar (304.5 psi) Compressor discharge pressure transmitter Settings : 04 0.05 mA for 0 bar (0 psi) 20 0.05 mA for 21 bar (304.5 psi) Differential pressure transmitter between the air inlet of GT and the bell of GT intake Settings : 04 0.02 mA for 0 mbar 20 0.10 mA for 27.4 mbar (11 in of H2O) Inlet gas fuel module pressure transmitter Settings : 04 0.05 mA for 0 bar (0 psi) 20 0.1 mA for 34.5 bar (500 psi) Fuel gas inter-valve pressure transmitter Settings : 04 0.05 mA for 0 bar (0 psi) 20 0.1 mA for 34.5 bar (500 psi)

0492

96AP-1A

0559

ACCY

0492

96AP-1B

0559

ACCY

0492

96AP-1C

0559

ACCY

0492

96BD-1

0559

ACCY

0417

96CD-1A

0557

ACCY

0417

96CD-1B

0557

ACCY

0417

96CD-1C

0557

ACCY

0492

96CS-1

0559

ACCY

0422

96FG-1

0991

GAS

0422

96FG-2A

0991

GAS

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

18/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4
MLI PID

392A8431
Devices MLI

19
Wiring Diagram

C
Safety Designation Fuel gas inter-valve pressure transmitter Settings : 04 0.05 mA for 0 bar (0 psi) 20 0.1 mA for 34.5 bar (500 psi) Fuel gas inter-valve pressure transmitter Settings : 04 0.05 mA for 0 bar (0 psi) 20 0.1 mA for 34.5 bar (500 psi) Fuel gas control valve (VGC-1) LVDT Settings : 0.7 0.1 V = 0% open 3.5 0.5 V = 100% open Lube oil system VPR-2 inlet pressure transmitter Settings : 04 0.05 mA for 0 bar (0 psi) 20 0.1 mA for 7 bar (101.5 psi) Emergency pump discharge pressure transmitter Settings : 04 0.05 mA for 0 bar (0 psi) 20 0.1 mA for 2 bar (29 psi) Low lube oil pressure transmitter generator Settings : 04 0.05 mA for 0 bar (0 psi) 20 0.1 mA for 1.72 bar (25 psi) Tank s air vacuum differential pressure transmitter Settings : 04 0.05 mA for 0 bar (0 psi) 20 0.1 mA for -15 mbarg (vacuum) Dew point and temperature transmitter Settings : Outlet 1 : 04 0.05 mA for -50C (-58 F) 20 0.05 mA for +50C (122 F) Outlet 2 : 04 0.05 mA for 0% RH 20 0.05 mA for 100 % RH Stop ratio fuel gas (VSR-1) LVDT Settings : 0.7 0.01 VAC for 0 mm Differential pressure transmitter of total filtration stages Settings : 04 0.05 mA for 0 mmH2O (0 inH2O) 20 0.1 mA for 254 mmH2O (10 inH2O) Differential pressure transmitter between air inlet and hoods Settings : 04 0.05 mA for 0 mmH2O (0 inH2O) 20 0.1 mA for 254 mmH2O (10 inH2O) Torque converter IGV position transmitter Settings : 04 0.05 mA for 0 tr of handwheel (full scale 0-242 tr) 20 0.05 mA for 242 of handwheel (full scale 0-242 tr)

TBFT-TMP-FR-GTE-0060 Rev : 001

0422

96FG-2B

0991

GAS

0422

96FG-2C

0991

GAS

0422

96GC-1,2

0509

GAS

0416

96QA-2

0926

ACCY

0416

96QE-2

0926

ACCY

0416

96QT-2B

ALT.

GENE

0416

96QV-1

0557

ACCY

0471

96RH

A040

FILT

0422

96SR-1,2

0507

GAS

0471

96TF-1

A040

FILT

0471

96TF-10

A040

FILT

0421

96TM-1

0605

ACCY

0469 0469

96TV-1 96TV-2

0548 0548

TURB TURB

LVDT (Linear variable displacement transmitter), compressor IGV actuator Settings : 0.7 0.01 VAC for 34 IGV angle LVDT (Linear variable displacement transmitter), compressor IGV actuator Settings : 0.7 0.01 VAC for 34 IGV angle Vibration sensor Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil) Settings : Gap : 1.4 0.05 mm (0.055 0.002 in) SIZE CAGE CODE DWG NO

0415

96VC-11

235A

TURB

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

19/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4
MLI PID 0415

392A8431
Devices MLI

20
Wiring Diagram TURB

C
Safety Designation Vibration sensor Characteristics : Output proximitor : 7.87 V/mm (0.2 V/mil) Settings : Gap : 1.4 0.05 mm (0.055 0.002 in) Gas mass flow transmitter Settings : 04 0.05 mA for 0 kg/s (0 lbm/s) 20 0.1 mA for 10 kg/s (22 lbm/s) Flow transmitter Settings : 04 0.2 mA for 0 m3/h (0 gpm) 20 0.2 mA for 20.4 0.1 m3/h (90 0.44 gpm) Flow transmitter Settings : 04 0.2 mA for 0 m3/h (0 gpm) 20 0.2 mA for 20.4 0.1 m3/h (90 0.44 gpm) Flow transmitter Settings : 04 0.2 mA for 0 m3/h (0 gpm) 20 0.2 mA for 20.4 0.1 m3/h (90 0.44 gpm) Atomizing air precooler air discharge thermocouple Characteristics : Type K Atomizing air precooler air discharge thermocouple Characteristics : Type K Control oil hydraulic accumulator Characteristics : 17.8 l (4.7 gal) | Nitrogen Settings : 51.7 1 bar (750 15 psi) Control oil hydraulic accumulator Characteristics : 17.8 l (4.70 gal) | Nitrogen Settings : 51.7 1 bar (750 15 psi) Thermocouple accessory compartment Characteristics : Type K Thermocouple gas compartment Characteristics : Type K

TBFT-TMP-FR-GTE-0060 Rev : 001

96VC-12

235A

0422

96VM-1

0639

OTHER

0462

96WF-1

A035

WI

0462

96WF-2

A035

WI

0462

96WF-3

A035

WI

0425 0425

AAT-1A AAT-2A

637T 637T

TURB TURB

0434

AH1-1

0908

N/A

0422

AH1-3

0991

N/A

0436 0436

AT-AC-1 AT-AC-11

1113 1195

ENCL-T ENCL-G

0436

AT-LC-1

637T

TURB

Air temperature load compartment Characteristics : Platinum PT100 | 100 Ohm at 0C (32F) | -50 to 260 C (-58 to 500 F) | 0.385 Ohm/C (0.214 Ohm/F) Air temperature turbine compartment Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) | 0.385 Ohm/C (0.214 Ohm/F) Thermocouple : turbine compartment enclosure Characteristics : Type K Thermocouple : turbine compartment enclosure Characteristics : Type K Water injection compartment temperature water injection compartment Characteristics : Type K Dual thermocouple temperature journal bearing n1 Characteristics : Type K Dual thermocouple temperature journal bearing n1 Characteristics : Type K Dual thermocouple temperature journal bearing n2 Characteristics : Type K Dual thermocouple temperature journal bearing n2 Characteristics : Type K SIZE CAGE CODE DWG NO

0436

AT-TC-1

637T

TURB

0436 0436 0436 0415 0415 0415 0415

AT-TC-2 AT-TC-3 AT-WI-1 BT-J1-1A,1B BT-J1-2A,2B BT-J2-1A,1B BT-J2-2A,2B

1113 1113 1659 235A 235A 235B 235B

ENCL-T ENCL-T ENCL-WI TURB TURB TURB TURB

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

20/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4
MLI PID 0415 0415 0415 0415 0415 0415 0425 0425 0415 0415 0415 0415

392A8431
Devices BT-J3-1A,1B BT-J3-2A,2B BT-TA1-4A,4B BT-TA1-8A,8B BT-TI1-1A,1B BT-TI1-6A,6B CA1 CA2 CT-DA-1 CT-DA-2 CT-IF-1 CT-IF-2 MLI 235C 235C 235A 235A 235A 235A 0607 1047 637T 637T 637T 637T

21
Wiring Diagram TURB TURB TURB TURB TURB TURB N/A N/A TURB TURB TURB TURB

C
Safety Designation Dual thermocouple temperature journal bearing n3 Characteristics : Type K Dual thermocouple temperature journal bearing n3 Characteristics : Type K

TBFT-TMP-FR-GTE-0060 Rev : 001

Dual thermocouple temperature pad n4 of thrust bearing n1 Characteristics : Type K Dual thermocouple temperature pad n8 of thrust bearing n1 Characteristics : Type K Dual thermocouple temperature pad n1 of counter thrust bearing n1 Characteristics : Type K Dual thermocouple temperature pad n6 of counter thrust bearing n1 Characteristics : Type K Main atomizing air compressor Characteristics : Centrifugal | 2.7 kg/s | Gear box shaft speed: 6600 rpm Booster atomizing air compressor Characteristics : Volumetric | 510 m3/h (2245.46 gal/min) | 4000 rpm Thermocouple compressor air discharge temperature Characteristics : Type K Thermocouple compressor air discharge temperature Characteristics : Type K Thermocouple temperature compressor air inlet Characteristics : Type K Thermocouple temperature compressor air inlet Characteristics : Type K Resistance temperature detector Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) | 0.385 Ohm/C (0.214 Ohm/F) Cranking motor stator Ph1 temperature sensor 1 Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) | 0.385 Ohm/C (0.214 Ohm/F) Cranking motor stator Ph1temperature sensor 2 Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) | 0.385 Ohm/C (0.214 Ohm/F) Cranking motor stator Ph2 temperature sensor 1 Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) | 0.385 Ohm/C (0.214 Ohm/F) Cranking motor stator Ph2 temperature sensor 2 Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) | 0.385 Ohm/C (0.214 Ohm/F) Cranking motor stator Ph3 temperature sensor 1 Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) | 0.385 Ohm/C (0.214 Ohm/F) Cranking motor stator Ph3 temperature sensor 2 Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) | 0.385 Ohm/C (0.214 Ohm/F) Liquid fuel purge air filter Characteristics : 5 m Filter on actuation air of atomizing air and purge systems Characteristics : 5 m Filter on actuation air of bleed valve 5th stage extraction air moisture separator SIZE CAGE CODE DWG NO

0492

CT-IF-3/R

637T

TURB

0421

ET-CRS-11/R

0603

ACCY

0421

ET-CRS-12/R

0603

ACCY

0421

ET-CRS-21/R

0603

ACCY

0421

ET-CRS-22/R

0603

ACCY

0421

ET-CRS-31/R

0603

ACCY

0421

ET-CRS-32/R

0603

ACCY

0477 0425 0417 0417

FA3-1 FA4-1 FA6 FA7

918T 0983 0909 0931

N/A N/A N/A N/A

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

21/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4
MLI PID 0462 0441 0441 0424

392A8431
Devices FA8-2 FAKJ-1 FAKJ-2 FD1-1 MLI A035 E026 E026 0613

22
Wiring Diagram N/A N/A N/A N/A

C
Safety Water injection air filter Characteristics : 5 m Pressure switch filter cleaning skid Screen type filter Designation

TBFT-TMP-FR-GTE-0060 Rev : 001

Flow divider Characteristics : type lineare, 7 elements with double pumps | 883 l/min (233 gpm) at 1650 rpm | 50 hz HP fuel filter Characteristics : Beta 40 = 75 HP fuel filter Characteristics : Beta 40 = 75 Filter before the pumps Characteristics : Mesh = 0.91 mm Hydraulic oil supply filter Characteristics : Beta 3 > 200 Hydraulic oil supply filter Characteristics : Beta 3 > 200 Hydraulic filter liquid fuel servo valve (control) Characteristics : 40 m Filter, hydraulic fluid supply , IGV controller assembly Characteristics : Beta 15 = 75 Servo hydraulic supply filter of stop ratio valve (VSR) Characteristics : 15 m abs Gas fuel control valve (VGC) servo hydraulic fluid supply filter Characteristics : 15 m abs Water injection flowmeter Characteristics : 1,4 m3/h (6 gpm) | Nominal K factor : 343.5 pulse/l (1300 pulse/US gallon) | 20.4 m3/h (90 gpm) High pressure filter Characteristics : Beta 13 = 75 Water injection upstream pump Y strainer Characteristics : Filtering media 800m Conical filter downstream flowmeter Characteristics : Filtering media 150m Torque converter and reversing gear Actuator assembly, inlet guide valve system Characteristics : Actuator operation limits : 31.5 0.5 to 87.75 0.25 Atomizing air precooler Lube oil filter Characteristics : Beta 40 = 75 Lube oil filter Characteristics : Beta 40 = 75 Lube oil cooler Lube oil cooler Lube oil thermocouple #1 bearing drain Characteristics : Type K Lube oil thermocouple #2 bearing drain Characteristics : Type K

0424 0424 0494 0434 0434 0424 0469 0422 0422

FF2-1 FF2-2 FF31-1 FH2-1 FH2-2 FH3 FH6-1 FH7-1 FH8-1

1014 1014 E021/E0 48 1051 1051 0992 0548 0507 0509

N/A N/A N/A N/A N/A N/A N/A N/A N/A

0462

FM1-1

A035

N/A

0462 0462 0462 0421 0469 0425 0416 0416 0416 0416 0416 0416

FW1-1 FW1-2 FW1-3 HM-1 HM3-1 HX1-1 LOF1-1 LOF1-2 LOHX-1 LOHX-2 LT-B1D-1 LT-B2D-1

A035 A035 A035 0605 0548 1003 1010 1010 1001 1001 637T 637T

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A TURB TURB

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

22/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4
MLI PID 0416 0416 0416 0416

392A8431
Devices LT-B3D-1 LT-BT1D-1 LT-G1D-1 LT-G2D-1 MLI 637T 637T ALT. ALT.

23
Wiring Diagram TURB TURB GENE GENE

C
Safety Designation Lube oil thermocouple #3 bearing drain Characteristics : Type K Lube oil thermocouple #1 bearing thrusts drain Characteristics : Type K

TBFT-TMP-FR-GTE-0060 Rev : 001

Lube oil thermocouple generator and load gear #1 bearing drain Characteristics : Type K Lube oil thermocouple generator and load gear #2 bearing drain Characteristics : Type K Resistance temperature in oil tank detector Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) | 0.385 Ohm/C (0.214 Ohm/F) Resistance temperature in oil tank detector Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) | 0.385 Ohm/C (0.214 Ohm/F) Lube oil temperature turbine header thermocouple Characteristics : Type K Lube oil temperature turbine header thermocouple Characteristics : Type K Lube oil temperature turbine header thermocouple Characteristics : Type K Gas fuel nozzle Main fuel pump Characteristics : Positive displacement screw pump | 2924 rpm | 68.9 bar (1000 psi) | 870.5 l/min (230 gpm) Unloading pump Characteristics : Volumetric pump | 25 l/min (6.6 gpm) Dosing pump Characteristics : Volumetric pump | 1500 rpm | 10 bar (145 psi) | Flow to define Dosing pump Characteristics : Volumetric pump | 1500 rpm | 10 bar (145 psi) | Flow to define Main hydraulic supply pump Characteristics : Volumetric pump | 1422 rpm | 105 bar (1500 psi) | 65 l/min (17.1 gpm) Auxiliary hydraulic supply pump Characteristics : Volumetric pump | 1450 rpm | 105 bar (1500 psi) | 45.4 l/min (12 gpm) Lube oil main pump Characteristics : Volumetric | 6.89 bar (100 psi) | 3000 l/min (792 gpm) Lube oil emergency pump Characteristics : Centrifugal | 1.37 bar (19.87 psi) | 1596 l/min (422 gpm) Breather valve of 501BA tank Characteristics : Normal : NC Settings : Overpressure : 0.15 bar (2.17 psi); Vaccum : 0.01 bar (0.15 psi) Water injection pump unit Characteristics : Centrifugal pump | 12263 rpm | 33 bar (480 psi) | 26.6 m3/h (117 gpm) Light warning auxiliaries compartment Characteristics : 0.015 | 50 hz | 230 UPS Fire alarm auxiliaries compartment Characteristics : Visual alarm | 24 VDC Fire alarm GT compartment Characteristics : Visual alarm | 24 VDC Fire alarm GT compartment Characteristics : Visual and audible alarm | 24 VDC SIZE CAGE CODE DWG NO

0416

LT-OT-1

1218

TURB

0416

LT-OT-2

1218

TURB

0416 0416 0416 0422 0424

LT-TH-1 LT-TH-2 LT-TH-3 MG1 PF1

637A 637A 637A 0512 0611 E021/E0 48 E021/E0 48 E021/E0 48 0627 0628 0601 1007 E021/E0 48 A035 1104 1113 1113 1113

ACCY ACCY ACCY N/A ACCY

0494 0494 0494 0434 0434 0416 0416

PFA-30 PFA-31 PFA-32 PH1 PH2 PQ1-1 PQ2-1

N/A N/A N/A N/A N/A N/A N/A

0494

PSV-31

N/A

0462 0426 0426 0426 0426

PW1-1 SLI-1 SLI-1A SLI-1B SLI-1C

N/A ACCY ENCL-T ENCL-T ENCL-T

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

23/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4
MLI PID 0426 0426 0426 0426 0426 0426 0426 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415

392A8431
Devices SLI-1D SLI-1E SLI-2 SLI-2B SLI-2C SLI-2E SLI-3C TT-IB-1 TT-IB-2 TT-IB-3 TT-WS1AO-1 TT-WS1AO-2 TT-WS1FI-1 TT-WS1FI-2 TT-WS2AO-1 TT-WS2AO-2 TT-WS2FO-1 TT-WS2FO-2 TT-WS3AO-1 TT-WS3AO-2 TT-WS3FO-1 TT-WS3FO-2 TT-XD-1 TT-XD-10 TT-XD-11 MLI 1195 1195 1104 1113 1113 1195 1113 637T 637T 637T 637T 637T 637T 637T 637T 637T 637T 637T 637T 637T 637T 637T 0623 0623 0623

24
Wiring Diagram ENCL-G ENCL-G ACCY ENCL-T ENCL-T ENCL-G ENCL-T TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB

C
Safety Designation Fire alarm gas compartment Characteristics : Visual alarm | 24 VDC Fire alarm gas compartment Characteristics : Visual and audible alarm | 24 VDC Light warning auxiliaries compartment Characteristics : 0.015 | 50 hz | 230 UPS Fire alarm GT compartment Characteristics : Visual alarm | 24 VDC Fire alarm GT compartment Characteristics : Visual and audible alarm | 24 VDC Fire alarm gas compartment Characteristics : Visual and audible alarm | 24 VDC Fire alarm load compartment Characteristics : Visual and audible alarm | 24 VDC Thermocouple temperature exhaust tunnel Characteristics : Type K Thermocouple temperature exhaust tunnel Characteristics : Type K Thermocouple temperature exhaust tunnel Characteristics : Type K

TBFT-TMP-FR-GTE-0060 Rev : 001

Thermocouple wheelspace temperature outer position after first wheel Characteristics : Type K Thermocouple wheelspace temperature outer position after first wheel Characteristics : Type K Thermocouple wheelspace temperature inner position forward first wheel Characteristics : Type K Thermocouple wheelspace temperature inner position forward first wheel Characteristics : Type K Thermocouple wheelspace temperature outer position after second wheel Characteristics : Type K Thermocouple wheelspace temperature outer position after second wheel Characteristics : Type K Thermocouple wheelspace temperature outer position forward second wheel Characteristics : Type K Thermocouple wheelspace temperature outer position forward second wheel Characteristics : Type K Thermocouple wheelspace temperature outer position after third wheel Characteristics : Type K Thermocouple wheelspace temperature outer position after third wheel Characteristics : Type K Thermocouple wheelspace temperature outer position forward third wheel Characteristics : Type K Thermocouple wheelspace temperature outer position forward third wheel Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K SIZE CAGE CODE DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

24/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4
MLI PID 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415

392A8431
Devices TT-XD-12 TT-XD-13 TT-XD-14 TT-XD-15 TT-XD-16 TT-XD-17 TT-XD-18 TT-XD-19 TT-XD-2 TT-XD-20 TT-XD-21 TT-XD-22 TT-XD-23 TT-XD-24 TT-XD-3 TT-XD-4 TT-XD-5 TT-XD-6 TT-XD-7 TT-XD-8 TT-XD-9 MLI 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623

25
Wiring Diagram TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB

C
Safety Designation Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Thermocouple temperature of GT exhaust Characteristics : Type K Gas fuel purge circuit valve Characteristics : Normal : NC Settings : Opening time shall be 30 5 seconds. Closing time shall be 10 seconds at maximum. Gas fuel purge circuit valve Characteristics : Normal : NC Settings : Opening time of VA13-2 should be less than VA13-1 False start drain valve Characteristics : Normal : FO SIZE CAGE CODE DWG NO

TBFT-TMP-FR-GTE-0060 Rev : 001

0477

VA13-1

0991

N/A

0477

VA13-2

0991

N/A

0442

VA17-1

1026

N/A

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

25/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4
MLI PID 0442 0442 0425 0477 0417 0417 0425 0417 0417

392A8431
Devices VA17-2 VA17-5 VA18-1 VA19-1 VA2-1 VA2-2 VA22-1 VA2-3 VA2-4 MLI 1026 1026 1070 918T 1022 1022 0922 1022 1022

26
Wiring Diagram N/A N/A N/A N/A N/A N/A N/A N/A N/A

C
Safety False start drain valve Characteristics : Normal : FO False start drain valve Characteristics : Normal : FO Atomizing air compressor pressure adjustment valve Characteristics : Normal : NC Liquid fuel purge air valve Characteristics : Normal : C to L opened ; U closed Compressor bleed valve Characteristics : Normal : NO Compressor bleed valve Characteristics : Normal : NO Designation

TBFT-TMP-FR-GTE-0060 Rev : 001

CA2 booster atomizing air compressor inlet air isolation butterfly valve Characteristics : Normal : NO Compressor bleed valve Characteristics : Normal : NO Compressor bleed valve Characteristics : Normal : NO Quick exhaust pneumatic valve for gas fuel purge valve VA13-1 Characteristics : Under pressure : 1 to 2 open and vent 3 closed Out of pressure : 2 open to vent 3 Quick exhaust pneumatic valve for gas fuel purge valve VA13-2 Characteristics : Under pressure : 1 to 2 open and vent 3 closed Out of pressure : 2 open to vent 3 Pneumatic valve Characteristics : Normal : NO Pneumatic valve Characteristics : Normal : NC Pneumatic valve Characteristics : Normal : NO Hydraulic system air bleed valve (main) Hydraulic system air bleed valve (auxiliary) By pass control valve Characteristics : Stroke = 28.57 mm (1.125 in) | Normal : NO Water injection flow control valve Characteristics : Normal : NC Check valve Characteristics : Normal : NC Check valve Characteristics : Normal : NC Check valve Characteristics : Normal : NC Liquid fuel nozzle check valve Characteristics : Normal : NC Settings : Cracking pressure : 8.27 0.34 bar (120 5 psi) Lube oil mist eliminator check valve Characteristics : Normal : NC Settings : beginning to open at -100 10 mm H2O (-3.94 0.4 in H20) at full speed no load SIZE CAGE CODE DWG NO

0477

VA36-1

0991

N/A

0477

VA36-2

0991

N/A

0494 0494 0494 0434 0434 0424 0462 0462 0462 0462

VA99-31 VA99-32 VA99-33 VAB1 VAB2 VC3 VC4-1 VCK100 VCK110 VCK111

E021/E0 48 E021/E0 48 E021/E0 48 0947 0947 0516 A035 A035 A035 A035

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

0424

VCK1-1T14

0961

N/A

0416

VCK20-13

A098

N/A

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

26/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4
MLI PID 0477

392A8431
Devices MLI

27
Wiring Diagram N/A

C
Safety Designation Liquid fuel primary nozzle purge air check valve Characteristics : Normal : NC Settings : Cracking pressure : Minimum 0.07 bar (1 psi) Hydraulic pump check valve for main pump Characteristics : Normal : NC Settings : Treshold = 1.5 0.1 bar (21.75 1.45 psi) Hydraulic pump check valve for auxiliary pump Characteristics : Normal : NC Settings : Treshold = 1.5 0.1 bar (21.75 1.45 psi) Turbine exhaust frame cooling check valve Characteristics : Normal : NC Settings : opening pressure : Non-adjutable : 7 mbar (0.1 psi) Turbine exhaust frame cooling check valve Characteristics : Normal : NC Settings : opening pressure : Non-adjutable : 7 mbar (0.1 psi) Gas control valve primary Characteristics : Stroke maxi = 38.1 mm (1.5 in) | Normal : NC Liquid fuel nozzle pressure selector valve Trip relay, hydraulic IGV Trip relay, hydraulic IGV Gas fuel dump valve VSR-1 valve Characteristics : Normal : NC Gas fuel dump valve VGC-1 valve Characteristics : Normal : NC Coriolis mass flow meter Hydraulic filter transfer valve Fuel liquid purge multiport valve Characteristics : Normal : NC Bearing header pressure regulator valve Characteristics : Normal : NC Settings : 1.72 +0.13/-0 bar (25 +2/-0 psi) Filter regulator Characteristics : Normal : NO Settings : 4 0.35 bar (58 5 psi) Hydraulic supply pump (PH1) compensator Settings : 103.4 1.37 bar (1500 20 psi)

TBFT-TMP-FR-GTE-0060 Rev : 001

VCK2-1T14

918T

0434

VCK3-1

0947

N/A

0434

VCK3-2

0947

N/A

0417

VCK7-1

A053

N/A

0417

VCK7-2

A053

N/A

0422 0424 0469 0469 0422 0422 0422 0434 0424

VGC-1 VH17-1 VH3-1A VH3-1B VH5-1 VH5-2 VM-1 VM4 VP-1

0509 0992 0548 0548 0507 0509 0639 1051 0961

GAS N/A N/A N/A GAS GAS N/A N/A N/A

0416

VPR2-1

1023

N/A

0494

VPR30-31

E021/E0 48 0627 0991 0991 918T A035 A035 A035 0922

N/A

0434 0477 0477 0477 0462 0462 0462 0425

VPR3-1 VPR44-1 VPR44-2 VPR54-1 VPR62-1 VPR62-11 VPR62-13 VPR68-1

N/A N/A N/A N/A N/A N/A N/A N/A

Filter pressure regulator on actuation air of gas fuel purge air valve Settings : 2.3 +0/-0.2 bar (33 +0/-3 psi) Filter pressure regulator on actuation air of gas fuel purge air valve Settings : 2.3 +0/-0.2 bar (33 +0/-3 psi) Filter pressure regulator on valve actuation air Settings : 3.27 +1.7/-0 bar (47.5 +2.7/-0 psi) Water injection control valve pressure regulation (part of VC4-1) Settings : 2,6 0.1 bar (37.7 1.5 psi) Water Injection stop valve pressure regulation (part of VS2-1) Settings : 6.2 0.1 bar (90 1.5 psi) Water Injection stop valve pressure regulation (part of VS2-2) Settings : 6.2 0.1 bar (90 1.5 psi) Pressure regulator valve for intrumentation air of VA22-1 Settings : 3.79 0.13 bar (55 2 psi)

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

27/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4
MLI PID 0462 0462

392A8431
Devices VQE1-1 VQE1-2 MLI A035 A035

28
Wiring Diagram N/A N/A

C
Safety Quick exhaust valve (part of VS2-1) Characteristics : Normal : NC Quick exhaust valve (part of VS2-2) Characteristics : Normal : NC Main lube oil pump pressure relief valve Characteristics : Normal : NC Settings : Opening at 6.89 + 0.13/-0 bar (100 + 2/-0 psi) Main hydraulic supply pump pressure relief valve Characteristics : Normal : NC Settings : 113.7 1.37 bar (1650 20 psi) Auxiliary hydraulic supply pump pressure relief valve Characteristics : Normal : NC Settings : 113.7 1.37 bar (1650 20 psi) LP hopper vibrator pressure relief valve Characteristics : Normal : NC Settings : Opening at 5 0.1 bar (72.5 1.5 psi) Fuel oil supply pressure relief valve Characteristics : Normal : NC Settings : 6.2 0.2 bar (87 2.9 psi) Main fuel pump pressure relief valve Characteristics : Normal : NC Settings : 82.7 1.72 bar (1200 25 psi) PFA-31 pump relief pressure valve Characteristics : Normal : NC Settings : Opening at 12 1 bar (174 14,5 psi) PFA-32 pump relief pressure valve Characteristics : Normal : NC Settings : Opening at 12 1 bar (174 14,5 psi) Fuel oil stop valve Characteristics : Normal : NC Water injection stop valve Characteristics : Normal : NC Water injection stop valve Characteristics : Normal : NC Designation

TBFT-TMP-FR-GTE-0060 Rev : 001

0416

VR1

1016

N/A

0434

VR21

0947

N/A

0434

VR22

0947

N/A

0441

VR26

E026

N/A

0424

VR27

0992

N/A

0424

VR4

0992

N/A

0494

VR60-31

E021/E0 48 E021/E0 48 0511 A035 A035 0507

N/A

0494

VR60-32

N/A

0424 0462 0462 0422

VS1 VS2-1 VS2-2 VSR-1

N/A N/A N/A GAS

Fuel gas stop/speed ratio valve Characteristics : Stroke maxi = 88.9 0.127 mm (3.5 0.005 in) | Normal : NC Thermostatic valve regulating lube oil temperature Characteristics : Normal : E to B open, C closed Settings : Starts to open at Oil T = 54 2C (130 3.6 F) Thermostatic valve regulating atomizing air temperature Characteristics : Normal : B to E open, C closed Settings : T air = 102 5 C (216 9 F) Resistance thermometer detector support legs water temperature Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) | 0.385 Ohm/C (0.214 Ohm/F) Resistance thermometer detector support legs water temperature Characteristics : Platinum PT100 | 100 Ohm at 0C (32 F) | -50 to 260 C (-58 to 500 F) | 0.385 Ohm/C (0.214 Ohm/F) Thermocouple temperature false start drain Characteristics : Type K Thermocouple temperature false start drain Characteristics : Type K

0420

VTR1-1

1035

N/A

0420

VTR2-1

1027

N/A

0420

WT-TL-1

637T

TURB

0420

WT-TL-2

637T 637T/09 20 637T/09 20

TURB

0442 0442

WWTD-1 WWTD-2

TURB TURB

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01EN
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET

28/ 28

Doc. Source : TBFT-ISP-FR-GTE-0020


This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

SIZE

DWG NO

SH

REV

A4

392A8431

C
REVISIONS

TBFT-TMP-FR-GTE-0060 Rev : 001

Rev A B C

Description Premire dition - P&ID 0471 : Changement de numro : 227D1412 au lieu de 219D2887 - P&ID 0462 : Modification caractristiques appareils 33WN-8, 90WN-1 et VPR62-1 P&ID 0422 : Modification de la tolrance de la course max. de la vanne VSR-1.

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

1/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4

392A8431

TBFT-TMP-FR-GTE-0060 Rev : 001

PRESSION : Toutes les pressions sont relatives, abs indique pression absolue.

Abrviations
AA ACF AD AE AMF DEC. DPDT DPG FC FO GF GFV GPL INC. LVDT MLI NC NO Normal OD OD OD OH OHT OL OLV OR PC Pente Safety SPDT SPST WD WF WR

Dsignations
Air datomisation Pression aval filtre huile contrle Air sortie compresseur Air dextraction Pression aval filtre principal huile Dcroissant Double contact, double ple Manomtre Pression diffrentielle Fermeture par scurit Ouverture par scurit Combustible gazeux Event de gaz Fuite aux garnitures vanne combine gaz Croissant Transmetteur de position linaire diffrentiel Model List Item : Code compos de 4 caractres utilis par General Electric pour identifier les composants, assemblages, plans ou spcifications, exemple : MLI 0414 pour la nomenclature des appareils de contrle Normalement ferm Normalement ouvert Niveau d'nergie zro absolu, aucune puissance, pas d'huile, aucune vitesse, aucune temprature Retour dhuile Retour dhuile au-dessus du niveau cuve huile Retour dhuile au-dessous du niveau cuve huile Huile de rgulation HP Huile de scurit HP Huile de graissage Event dhuile de graissage Huile de graissage module Point de connexion Le sens de la flche indique l'coulement gravitationnel du liquide d la pente Niveau dIntgrit de Scurit (une croix signifie que lappareil appartient une boucle de scurit du personnel). Ne pas modifier les lments ou les rglages dune boucle de scurit. Simple contact, double ple Simple contact, simple ple Egouttures deau Alimentation deau Retour deau

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

2/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4

392A8431

C Description

TBFT-TMP-FR-GTE-0060 Rev : 001

Schma de cblage
ACCY AIR AIR DRY CHROM CLEAN CO2 ENCL-G ENCL-LF ENCL-LO ENCL-T ENCL-V ENCL-WI FG-SSOV FILT GAS GAS HEAT GENE IBH LF-AA LF AA WI LF-SR LF-TR LF-FD LF-H LF-TPH LF-PH LF-FT-PR LO FG LOAD MIST OIL STEAM

L'appareil est dans le schma de cblage auxiliaires (MLI 401A) L'appareil est dans le schma de cblage du module de ventilation & refroidissement (MLI A132) Lappareil est dans le schma de cblage du module de schage dair (MLI 1049) Lappareil est dans le schma de cblage du module chromatographe gaz (MLI G023) Lappareil est dans le schma de cblage du module de nettoyage (MLI E026) L'appareil est dans le plan d'interface du package module CO2 protection incendie (MLI A068) L'appareil est dans le plan d'interface du package module gaz (MLI 1195) L'appareil est dans le plan d'interface du package module fioul / air atomisation / injection d'eau (MLI 1152) L'appareil est dans le plan d'interface du package module huile / gaz (MLI 1137) L'appareil est dans le plan d'interface du package turbine (MLI 1113) L'appareil est dans le plan d'interface du package module ventilation (MLI 1643) L'appareil est dans le plan d'interface du package module d'injection d'eau (MLI 1196) L'appareil est dans le schma de cblage du module gaz, SSOV & vent (MLI G064) L'appareil est dans le schma de cblage du filtre air (MLI A040) L'appareil est dans le schma de cblage module gaz (MLI 0991 ou 401G) L'appareil est dans le schma de cblage du module traitement et rchauffage gaz (G025) L'appareil est dans le schma de cblage de l'alternateur L'appareil est dans le schma de cblage rchauffage entre d'air (MLI A037) The device is in the liquid fuel / atomizing air module wiring diagram (MLI A162) L'appareil est dans le schma de cblage module fioul/air atomisation/injection eau (MLI A162) L'appareil est dans le schma de cblage du module de recirculation fioul (MLI 969S) L'appareil est dans le schma de cblage du module de traitement fioul (MLI E020) L'appareil est dans le schma de cblage du diviseur de dbit fioul (MLI 0613) L'appareil est dans le schma de cblage du module de rchauffage fioul (MLI E041) L'appareil est dans le schma de cblage du module de transfert , pompage et rchauffage fioul (MLI E047) L'appareil est dans le schma de cblage du module de pompage et rchauffage fioul (MLI A245) L'appareil est dans le schma de cblage du module totaliseur de dbut et rgulation de pression fioul (MLI A246) L'appareil est dans le schma de cblage module huile / gaz (MLI A160) L'appareil est dans le schma de cblage du rducteur de puissance (MLI A012) L'appareil est dans le plan d'arrangement du dshuileur (MLI A098) L'appareil est dans le schma de cblage module huile (MLI 0990 ou 401H) L'appareil est dans le schma de cblage module d'injection vapeur (MLI A135)

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

3/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
TURB TURN-GEAR VAN WASH WI

392A8431

TBFT-TMP-FR-GTE-0060 Rev : 001

L'appareil est dans le schma de cblage turbine (MLI 401T) L'appareil est dans le schma de cblage du vireur (MLI A073) L'appareil est dans le schma de cblage module d'injection additive de vanadium (MLI E021) L'appareil est dans le schma de cblage module lavage turbine et compresseur (MLI E025) L'appareil est dans le schma de cblage module d'injection d'eau (MLI A035)

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

4/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4

392A8431

C MLI P&ID
0415 0416 0417 0419 0420 0421 0422 0424 0425 0426 0428 0431 0432 0434 0436 0441 0442 0462 0469 0471 0474 0477 0482 0491 0492 0494 0969 G044

TBFT-TMP-FR-GTE-0060 Rev : 001

Nom du sytme
Systme Instrumentation Turbine Systme Huile de Lubrification Systme Air Refroidissement et Etanchit Systme Air Instrument Systme Eau de Refroidissement Systme de Lancement Systme Combustible Gaz Systme Combustible Liquide Systme Air Atomisation Systme Protection Incendie Systme Tuyauterie Poste Air Systme Injection Vapeur Systme Rchauffage Air Aspiration Systme Alimentation Huile HP Systme Chauffage et Ventilation Systme Nettoyage Compresseur et Turbine Systme Lavage Compresseur et Turbine Systme Injection d'Eau Systme Commande Aubes Variables Compresseur Systme Dbit Aspiration et Echappement Systme Dtection Gaz Systme Balayage Combustible Systme de Principe Combustible Gaz Systme d'Injection N2 Systme Moniteur de Performances Systme Module d'Injection Additif Systme Lignes Interconnexions Systme Filtration et Vanne d'Arrt Gaz

Systme
CD LO CSA APU CW SM GF LF AA FP AE SI IAR HS HV TCC TCW WI IGV IE GD FPU GFPS NI PM LFAD IL GFF

Rfrence
227D1199 227D1331 219D2331 N/A 219D2889 205D4866 227D1390 227D1347 227D1078 219D2715 N/A N/A N/A 209D7043 219D2734 227D1308 219D1293 227D1360 219D1732 227D1412 209D7635 219D1141 N/A N/A 214D1258 219D1937 N/A N/A

Rev
A F C D C C E D B

C C A C A A A A B

C B

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

5/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0425 0425 0417 0424 0422 0422 0424 0494 0441 0441 0424

392A8431
Appareils 20AA-18 20AB-1 20CB-1 20CF-1 20FGC-1 20FGS-1 20FL-1 20IA-31 20KF 20KF/PB 20PF-100 MLI 918T 0922 1071 0510 0509 0507 0511 E021/E0 48 E026 E026 0961

6
Schma cblage TURB ACCY TURB ACCY GAS GAS ACCY VAN CLEAN CLEAN TURB

C
Safety Dsignation

TBFT-TMP-FR-GTE-0060 Rev : 001

Electrovanne air atomisation pour la commande de VA18-1 Caractristiques : Normal : 1 vers 3 ouvert ; 2 ferm | 0,035 kW | 125 VDC Electrovanne air atomisation pour la commande de VA22-1 Caractristiques : Normal : 1 vers 3 ouvert ; 2 ferm | 0,035 kW | 125 VDC Electrovanne commande vanne anti-pompage compresseur Caractristiques : Normal : B vers C ouvert, A ferm | 0,04 kW | 125 VDC Embrayage lectromagnetique pompe fuel Caractristiques : Normal : NO | 125 VDC | 0,16 kW (max) Electrovanne de dclenchement vanne de controle gaz (VGC-1) Caractristiques : Normal : NO | 0,0156 kW | 125 VDC Electrovanne arrt combustible gaz Caractristiques : Normal : NO | 0,0156 kW | 125 VDC Electrovanne arrt combustible liquide Caractristiques : Normal : NC | 0,02 kW | 125 VDC Electrovanne de commande de la vanne VA99-32 Caractristiques : Normal : 1 vers 2 ferm | 12 W | 125 VDC Vanne motorise skid de nettoyage Caractristiques : 230 VAC | Normal : NC | 50 hz | 0,045 kW Bouton-poussoir skid de nettoyage Electrovanne commande vanne multiport purge fuel liquide VP-1 et VP-2 Caractristiques : Normal : A vers P ouvert. B ferm | 40 W | 125 VDC Electrovanne de commande de la VA13-1 Caractristiques : Normal : 1 vers 3 ouvert ; 2 ferm | 0,035 kW | 125 VDC Rglages : Installation d un robinet-pointeau en amont de 20PG-1 pour rgler le temps d ouverture de VA13-1 30 secondes Electrovanne de commande de la VA13-2 Caractristiques : Normal : 1 vers 3 ouvert ; 2 ferm | 0,035 kW | 125 VDC Electrovanne de commande de la VA19-1 Caractristiques : Normal : 1 vers 3 ouvert ; 2 ferm | 0,035 kW | 125 VDC Electrovanne d appoint / dcharge du convertisseur de couple Caractristiques : Normal : NC Electrovanne systme dclenchement des aubes variables entre compresseur (IGV) Caractristiques : Normal : NO | 0,1 kW | 125 VDC Vanne motorise lavage compresseur off-Line Caractristiques : 230 VAC | Normal : NC | 50 hz | 0,072 kW Vanne motorise lavage turbine Caractristiques : 230 VAC | Normal : NC | 50 hz | 0,23 kW Vanne motorise lavage compresseur on-Line Caractristiques : 230 VAC | Normal : NC | 50 hz | 0,072 kW Electrovanne vent combustible gaz Caractristiques : Normal : NO | 0,009 kW | 125 VDC Electrovanne de mise l vent de la purge gaz Caractristiques : Normal : NO | 0,125 kW | 125 VDC Electrovanne arrt injection d eau Caractristiques : Normal : NO | 0,0112 kW | 125 VDC Electrovanne d arrt injection d eau (partie de VS2-2) Caractristiques : Normal : NO | 0,0112 kW | 125 VDC Electrovanne alimentation eau de refroidissement des clapets fuel Caractristiques : Normal : NO | 0,0112 kW | 125 VDC

0477

20PG-1

0991

GAS

0477 0477 0421 0469 0442 0442 0442 0422 0477 0462 0462 0420

20PG-2 20PL-1 20TU-1 20TV-1 20TW-1 20TW-2 20TW-3 20VG-1 20VG-2 20WN-1 20WN-2 20WN-30

0991 918T 0605 0548 0953 0983 0953 0991 0991 A035 A035 0963

GAS TURB ACCY TURB TURB TURB TURB GAS GAS WI WI TURB

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

6/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0425 0436 0436 0421 0421 0421 0436 0436 0436 0436 0436 0436 0436 0434 0436 0416 0416 0416 0416 0421 0417 0417 0436 0436 0462

392A8431
Appareils 23AB-1 23BT-1 23BT-2 23CR-1 23CR-2 23CR-3 23HA-11 23HA-12 23HA-13 23HA-14 23HA-15 23HA-16 23HA-30 23HQ-1 23HT-30 23QA-1 23QT-1 23QT-2 23QV-1A 23TG-1 23TK-1 23TK-2 23VG-1 23VG-2 23WN-1 MLI 1047 1605 1605 0603 0603 0603 1658 1658 1658 1658 1658 1658 1113 0628 1113 1006 0938 0938 A098 0603 1233 1233/A 132 1605 1605 A035

7
Schma cblage ACCY ENCL-T ENCL-T ACCY ACCY ACCY ENCL-G ENCL-G ENCL-G ENCL-G ENCL-G ENCL-G ENCL-T ACCY ENCL-T ACCY ACCY ACCY MIST ACCY ACCY ACCY ENCL-T ENCL-T WI

C
Safety Dsignation Rsistance anti-condensation du moteur 88AB-1 Caractristiques : 50 hz | 230 VAC | 0,05 kW Rsistance anti-condensation du moteur 88BT-1 Caractristiques : 50 hz | 230 VAC | 0,05 kW Rsistance anti-condensation du moteur 88BT-2 Caractristiques : 50 hz | 230 VAC | 0,05 kW Rsistance anti-condensation du moteur 88CR-1 Caractristiques : 50 hz | 230 VAC | 0,18 kW Rsistance anti-condensation du moteur 88CR-1 Caractristiques : 50 hz | 230 VAC | 0,18 kW Rsistance anti-condensation du moteur 88CR-1 Caractristiques : 50 hz | 230 VAC | 0,18 kW Chauffage compartiment gaz Caractristiques : 50 hz | 400 VAC | 3,9 kW Chauffage entre d air du compartiment gaz Caractristiques : 50 hz | 400 VAC | 15 kW Chauffage entre d air du compartiment gaz Caractristiques : 50 hz | 400 VAC | 15 kW Chauffage entre d air du compartiment gaz Caractristiques : 50 hz | 400 VAC | 15 kW Chauffage entre d air du compartiment gaz Caractristiques : 50 hz | 400 VAC | 15 kW Chauffage entre d air du compartiment gaz Caractristiques : 50 hz | 400 VAC | 15 kW Chauffage compartiment auxiliaires Caractristiques : 50 hz | 400 VAC | 15 kW Rsistance anti-condensation du moteur 88HQ-1 Caractristiques : 50 hz | 230 VAC | 0,05 kW Chauffage compartiment turbine Caractristiques : 50 hz | 400 VAC | 20 kW Rsistance anti-condensation du moteur 88QA-1 Caractristiques : 50 hz | 230 VAC | 0,1 kW Thermoplongeur rservoir d huile Caractristiques : 50 hz | 400 VAC | 13,0 kW Thermoplongeur rservoir d huile Caractristiques : 50 hz | 400 VAC | 13,0 kW Rsistance anti-condensation du moteur 88QV-1A Caractristiques : 50 hz | 230 VAC | 0,05 kW Rsistance anti-condensation du moteur 88TG-1 Caractristiques : 50 hz | 230 VAC | 0,05 kW Rsistance anti-condensation du moteur 88TK-1 Caractristiques : 50 hz | 230 VAC | 0,05 kW Rsistance anti-condensation du moteur 88TK-2 Caractristiques : 50 hz | 230 VAC | 0,05 kW Rsistance anti-condensation du moteur 88VG-1 Caractristiques : 50 hz | 230 VAC | 0,05 kW Rsistance anti-condensation du moteur 88VG-2 Caractristiques : 50 hz | 230 VAC | 0,05 kW Rsistance anti-condensation moteur 88WN-1 Caractristiques : 50 hz | 230 VAC | 0,05 kW SIZE CAGE CODE DWG NO

TBFT-TMP-FR-GTE-0060 Rev : 001

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

7/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0436 0471 0415 0415 0415 0415 0415

392A8431
Appareils 23WR-30 27TF-1 28FD-10 28FD-11 28FD-4 28FD-5 30SG-1 MLI 1196 A040 1121 1121 1121 1121 1213

8
Schma cblage ENCL-WI FILT TURB TURB TURB TURB TURB

C
Safety Dsignation Chauffage enceinte skid injection d eau Caractristiques : 50 hz | 400 VAC | 9 kW Report d alarme gnral filtre air Dtecteur de flamme chambre de combustion n10 Dtecteur de flamme chambre de combustion n11 Dtecteur de flamme chambre de combustion n4 Dtecteur de flamme chambre de combustion n5 Relais alarme du transformateur d allumage Caractristiques : Normal : NO

TBFT-TMP-FR-GTE-0060 Rev : 001

0436

33BT-1

1605

ENCL-T

Fin de course clapet anti-retour de la ventilation du compartiment TG Caractristiques : Normal : NO Rglages : Volet ferm : fin de course actionn, contact ferm Fin de course clapet anti-retour de la ventilation du compartiment TG Caractristiques : Normal : NO Rglages : Volet ferm : fin de course actionn, contact ferm Fin de course vanne anti-pompage (11me tage) Caractristiques : Normal : NO Rglages : Vanne ouverte : fin de course actionn, contact ferm Fin de course vanne anti-pompage (11me tage) Caractristiques : Normal : NO Rglages : Vanne ouverte : fin de course actionn, contact ferm Fin de course vanne anti-pompage (11me tage) Caractristiques : Normal : NO Rglages : Vanne ouverte : fin de course actionn, contact ferm Fin de course vanne anti-pompage (11me tage) Caractristiques : Normal : NO Rglages : Vanne ouverte : fin de course actionn, contact ferm Fin de course porte du compartiment auxiliaires Caractristiques : Normal : NO Rglages : Porte ferme : fin de course actionn, contact ferm Fin de course porte du compartiment puissance compartiment gaz Caractristiques : Normal : NO Rglages : Porte ferme : fin de course actionn, contact ferm Fin de course porte du compartiment puissance compartiment gaz Caractristiques : Normal : NO Rglages : Porte ferme : fin de course actionn, contact ferm Fin de course porte du compartiment gaz Caractristiques : Normal : NO Rglages : Porte ferme : fin de course actionn, contact ferm Fin de course porte du compartiment gaz Caractristiques : Normal : NO Rglages : Porte ferme : fin de course actionn, contact ferm Fin de course porte du compartiment auxiliaires Caractristiques : Normal : NO Rglages : Porte ferme : fin de course actionn, contact ferm Fin de course porte du compartiment turbine Caractristiques : Normal : NO Rglages : Porte ferme : fin de course actionn, contact ferm Fin de course porte du compartiment turbine Caractristiques : Normal : NO Rglages : Porte ferme : fin de course actionn, contact ferm

0436

33BT-2

1605

ENCL-T

0417

33CB-1

1022

TURB

0417

33CB-2

1022

TURB

0417

33CB-3

1022

TURB

0417

33CB-4

1022

TURB

0436

33DT-1

1605

ENCL-T

0436

33DT-11

1658

ENCL-G

0436

33DT-12

1658

ENCL-G

0436

33DT-13

1658

ENCL-G

0436

33DT-14

1658

ENCL-G

0436

33DT-2

1605

ENCL-T

0436

33DT-3

1605

ENCL-T

0436

33DT-4

1605

ENCL-T

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

8/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0424

392A8431
Appareils MLI

9
Schma cblage ACCY

C
Safety Dsignation

TBFT-TMP-FR-GTE-0060 Rev : 001

33FL-1

0511

Fin de course vanne arrt combustible liquide Caractristiques : Normal : NO Rglages : Vanne ferme : fin de course actionn, contact ferm Fin de course clapet anti-retour de la ventilation de l enceinte du skid injection d eau Caractristiques : Normal : NO Rglages : Volet ferm : fin de course actionn, contact ferm Fin de course clapet anti-retour de la ventilation de l enceinte du skid injection d eau Caractristiques : Normal : NO Rglages : Volet ferm : fin de course actionn, contact ferm Fin de course vanne skid de nettoyage Caractristiques : Normal : NO Rglages : Vanne ferme : fin de course actionn, contact ferm Fin de course vanne skid de nettoyage Caractristiques : Normal : NO Rglages : Vanne ouverte : fin de course actionn, contact ferm Fin de course sur vanne multiport VP-1 Caractristiques : Normal : NO Rglages : Vanne ferme : fin de course actionn, contact ferm Fin de course position fermeture de VA13-1 Caractristiques : Normal : NO Rglages : Vanne ferme : fin de course actionn, contact ferm Fin de course position ouverture de VA13-1 Caractristiques : Normal : NO Rglages : Vanne ouverte : fin de course actionn, contact ferm Fin de course position fermeture de VA13-2 Caractristiques : Normal : NO Rglages : Vanne ferme : fin de course actionn, contact ferm Fin de course position ouverture de VA13-2 Caractristiques : Normal : NO Rglages : Vanne ouverte : fin de course actionn, contact ferm Fin de course position lectrovanne convertisseur de couple Caractristiques : Normal : NO Rglages : 20TU-1 au repos : fin de course actionn, contact ferm Fin de course de vanne de faux dpart Caractristiques : Normal : NO Rglages : Vanne ouverte : fin de course actionn, contact ferm Fin de course couple bas convertisseur de couple Caractristiques : Normal : NO, vanne ferme pour IGV ferm ou couple max Rglages : Rgl 3 tr de volant (pleine chelle 0-242 tr) Fin de course couple haut convertisseur de couple Caractristiques : Normal : NO, vanne ferme pour IGV ferm ou couple max Rglages : Rgl 242 tr de volant (pleine chelle 0-242 tr) Fin de course clapet anti-retour de la ventilation du compartiment puissance Caractristiques : Normal : NO Rglages : Volet ferm : fin de course actionn, contact ferm Fin de course de la vanne d vent du systme combustible gaz Caractristiques : Normal : NO Rglages : Vanne ferme : fin de course actionn, contact ferm Fin de course clapet anti-retour de la ventilation du compartiment puissance Caractristiques : Normal : NO Rglages : Volet ferm : fin de course actionn, contact ferm Fin de course clapet anti-retour de la ventilation du compartiment gaz Caractristiques : Normal : NO Rglages : Volet ferm : fin de course actionn, contact ferm

0436

33JS-1

1659

ENCL-WI

0436

33JS-2

1659

ENCL-WI

0441

33KF-1

E026

CLEAN

0441

33KF-2

E026

CLEAN

0424

33PF-1

0961

TURB

0477

33PG-1

0991

GAS

0477

33PG-2

0991

GAS

0477

33PG-3

0991

GAS

0477

33PG-4

0991

GAS

0421

33TC-1

0605

ACCY

0442

33TFD-1

1026

TURB

0421

33TM-5

0605

ACCY

0421

33TM-6

0605

ACCY

0436

33VG-1

1605

ENCL-T

0422

33VG-11

0991

GAS

0436

33VG-2

1605

ENCL-T

0436

33VL-1

1658

ENCL-G

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

9/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0436

392A8431
Appareils MLI

10
Schma cblage ENCL-G

C
Safety Dsignation

TBFT-TMP-FR-GTE-0060 Rev : 001

33VL-2

1658

Fin de course clapet anti-retour de la ventilation du compartiment gaz Caractristiques : Normal : NO Rglages : Volet ferm : fin de course actionn, contact ferm Fin de course vanne de contrle (partie de VC4-1) Caractristiques : Normal : NO Rglages : Vanne compltement ouverte : fin de course activ, contact ferm Fin de course vanne de contrle (partie de VC4-1) Caractristiques : Normal : NO Rglages : Vanne compltement ferme : fin de course actionn, contact ferm Fin de course vanne stop (partie de VS2-1) Caractristiques : Normal : NO Rglages : Vanne compltement ouverte : fin de course activ, contact ferm Fin de course vanne stop (partie de VS2-1) Caractristiques : Normal : NO Rglages : Vanne compltement ferme : fin de course activ, contact ferm Fin de course vanne stop (partie de VS2-2) Caractristiques : Normal : NO Rglages : Vanne compltement ouverte : fin de course activ, contact ferm Fin de course vanne stop (partie de VS2-2) Caractristiques : Normal : NO Rglages : Vanne compltement ferme : fin de course activ, contact ferm Capteur de vibration Caractristiques : Pour 25,4 mm/s, 150 7,5 mV crte Capteur de vibration Caractristiques : Pour 25,4 mm/s, 150 7,5 mV crte Capteur de vibration Caractristiques : Pour 25,4 mm/s, 150 7,5 mV crte Capteur de vibration Caractristiques : Pour 25,4 mm/s, 150 7,5 mV crte Capteur de vibration Caractristiques : Pour 25,4 mm/s, 150 7,5 mV crte Acclromtre corps compresseur Caractristiques : 1,02 mV/m/s2 (10 mV/g) 5% 3,94 mV/mm/s 5% Capteur de vibration Caractristiques : Sortie proximitor : 7,87 V/mm Rglages : Entrefer : 1,4 0,05 mm Capteur de vibration Caractristiques : Sortie proximitor : 7,87 V/mm Rglages : Entrefer : 1,4 0,05 mm Capteur de vibration Caractristiques : Sortie proximitor : 7,87 V/mm Rglages : Entrefer : 1,4 0,05 mm Capteur de vibration Caractristiques : Sortie proximitor : 7,87 V/mm Rglages : Entrefer : 1,4 0,05 mm Capteur de vibration Caractristiques : Sortie proximitor : 7,87 V/mm Rglages : Entrefer : 1,4 0,05 mm Capteur de vibration Caractristiques : Sortie proximitor : 7,87 V/mm Rglages : Entrefer : 1,4 0,05 mm

0462

33WN-1

A035

WI

0462

33WN-2

A035

WI

0462

33WN-3

A035

WI

0462

33WN-4

A035

WI

0462

33WN-7

A035

WI

0462

33WN-8

A035

WI

0415 0415 0415 0415 0415

39V-1A 39V-1B 39V-2A 39V-3A 39V-3B

1218 1218 1218 1218 1218

TURB TURB TURB TURB TURB

0415

39V-CC

1218

TURB

0415

39VS-11

235A

TURB

0415

39VS-12

235A

TURB

0415

39VS-21

235B

TURB

0415

39VS-22

235B

TURB

0415

39VS-23

235B

TURB

0415

39VS-24

235B

TURB

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

10/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0415

392A8431
Appareils MLI

11
Schma cblage TURB

C
Safety Dsignation Capteur de vibration Caractristiques : Sortie proximitor : 7,87 V/mm Rglages : Entrefer : 1,4 0,05 mm Capteur de vibration Caractristiques : Sortie proximitor : 7,87 V/mm Rglages : Entrefer : 1,4 0,05 mm Bris de glace porte d accs compartiment auxiliaire Caractristiques : Normal : NO Bris de glace porte d accs compartiment TG Caractristiques : Normal : NO Bris de glace porte d accs compartiment auxiliaire Caractristiques : Normal : NO Bris de glace porte d accs compartiment TG Caractristiques : Normal : NO Bris de glace porte d accs compartiment puissance Caractristiques : Normal : NO Bris de glace porte d accs compartiment gaz Caractristiques : Normal : NO Bris de glace porte d accs compartiment gaz Caractristiques : Normal : NO Bouton-poussoir lavage off-Line Caractristiques : Normal : NO Bouton-poussoir lavage turbine Caractristiques : Normal : NO Dtecteur thermostatique incendie compartiment auxiliaires Caractristiques : Normal : NO Rglages : Ferm : 163 14C Dtecteur thermostatique incendie compartiment auxiliaires Caractristiques : Normal : NO Rglages : Ferm : 163 14C Dtecteur thermostatique incendie compartiment auxiliaires Caractristiques : Normal : NO Rglages : Ferm : 163 14C Dtecteur thermostatique incendie compartiment auxiliaires Caractristiques : Normal : NO Rglages : Ferm : 163 14C Dtecteur thermostatique incendie compartiment auxiliaires Caractristiques : Normal : NO Rglages : Ferm : 163 14C Dtecteur thermostatique incendie compartiment auxiliaires Caractristiques : Normal : NO Rglages : Ferm : 163 14C Dtecteur thermostatique incendie compartiment auxiliaires Caractristiques : Normal : NO Rglages : Ferm : 163 14C Dtecteur thermostatique incendie compartiment auxiliaires Caractristiques : Normal : NO Rglages : Ferm : 163 14C Dtecteur thermostatique incendie compartiment auxiliaire Caractristiques : Normal : NO Rglages : Ferm : 163 14C

TBFT-TMP-FR-GTE-0060 Rev : 001

39VS-31

235C

0415

39VS-32

235C

TURB

0426 0426 0426 0426 0426 0426 0426 0442 0442

43CP-1 43CP-2 43CP-3 43CP-4 43CP-5 43CP-6 43CP-7 43TW-1/PB 43TW-2/PB

1113 1113 1153 1113 1113 1195 1195 1105 1105

ENCL-T ENCL-T ENCL-T ENCL-T ENCL-T ENCL-G ENCL-G TURB TURB

0426

45FA-10A

1113

ENCL-T

0426

45FA-10B

1113

ENCL-T

0426

45FA-11A

1113

ENCL-T

0426

45FA-11B

1113

ENCL-T

0426

45FA-12A

1113

ENCL-T

0426

45FA-12B

1113

ENCL-T

0426

45FA-13A

1113

ENCL-T

0426

45FA-13B

1113

ENCL-T

0426

45FA-1A

1104

ACCY

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

11/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0426

392A8431
Appareils MLI

12
Schma cblage ACCY

C
Safety Dsignation Dtecteur thermostatique incendie compartiment auxiliaire Caractristiques : Normal : NO Rglages : Ferm : 163 14C Dtecteur thermostatique incendie compartiment auxiliaire Caractristiques : Normal : NO Rglages : Ferm : 163 14C Dtecteur thermostatique incendie compartiment auxiliaire Caractristiques : Normal : NO Rglages : Ferm : 163 14C Dtecteur thermostatique incendie compartiment gaz Caractristiques : Normal : NO Rglages : Ferm : 163 14C Dtecteur thermostatique incendie compartiment gaz Caractristiques : Normal : NO Rglages : Ferm : 163 14C Dtecteur thermostatique incendie compartiment gaz Caractristiques : Normal : NO Rglages : Ferm : 163 14C Dtecteur thermostatique incendie compartiment gaz Caractristiques : Normal : NO Rglages : Ferm : 163 14C Dtecteur thermostatique incendie compartiment TG Caractristiques : Normal : NO Rglages : Ferm : 316 14C Dtecteur thermostatique incendie compartiment TG Caractristiques : Normal : NO Rglages : Ferm : 316 14C Dtecteur thermostatique incendie compartiment TG Caractristiques : Normal : NO Rglages : Ferm : 316 14C Dtecteur thermostatique incendie compartiment TG Caractristiques : Normal : NO Rglages : Ferm : 316 14C Dtecteur thermostatique incendie compartiment TG Caractristiques : Normal : NO Rglages : Ferm : 316 14C Dtecteur thermostatique incendie compartiment TG Caractristiques : Normal : NO Rglages : Ferm : 316 14C Dtecteur thermostatique incendie compartiment puissance Caractristiques : Normal : NO Rglages : Ferm : 385 14C Dtecteur thermostatique incendie compartiment puissance Caractristiques : Normal : NO Rglages : Ferm : 385 14C Dtecteur thermostatique incendie compartiment puissance Caractristiques : Normal : NO Rglages : Ferm : 316 14C Dtecteur thermostatique incendie compartiment puissance Caractristiques : Normal : NO Rglages : Ferm : 316 14C Dtecteur gaz dans gaine de ventilation compartiment gaz Caractristiques : Gamme de mesure : 0 20% LIE

TBFT-TMP-FR-GTE-0060 Rev : 001

45FA-1B

1104

0426

45FA-2A

1104

ACCY

0426

45FA-2B

1104

ACCY

0426

45FA-6A

0991

GAS

0426

45FA-6B

0991

GAS

0426

45FA-7A

0991

GAS

0426

45FA-7B

0991

GAS

0426

45FT-1A

1103

TURB

0426

45FT-1B

1103

TURB

0426

45FT-2A

1154

TURB

0426

45FT-2B

1154

TURB

0426

45FT-3A

1154

TURB

0426

45FT-3B

1154

TURB

0426

45FT-8A

1160

TURB

0426

45FT-8B

1160

TURB

0426

45FT-9A

1160

TURB

0426

45FT-9B

1160

TURB

0474

45HA-4

1658

ENCL-G

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

12/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0474 0474 0474 0474 0474 0474 0474 0474

392A8431
Appareils 45HA-5 45HA-6 45HT-1 45HT-2 45HT-3 45HT-4 45HT-5 45HT-6 MLI 1658 1658 1113 1113 1113 1605 1605 1605

13
Schma cblage ENCL-G ENCL-G TURB TURB TURB ENCL-T ENCL-T ENCL-T

C
Safety Dsignation Dtecteur gaz dans gaine de ventilation compartiment gaz Caractristiques : Gamme de mesure : 0 20% LIE Dtecteur gaz dans gaine de ventilation compartiment gaz Caractristiques : Gamme de mesure : 0 20% LIE Dtecteur gaz compartiment turbine Caractristiques : Gamme de mesure : 0 20% LIE Dtecteur gaz compartiment turbine Caractristiques : Gamme de mesure : 0 20% LIE Dtecteur gaz compartiment turbine Caractristiques : Gamme de mesure : 0 20% LIE

TBFT-TMP-FR-GTE-0060 Rev : 001

Dtecteur gaz compartiment turbine gaine de ventilation compartiment turbine Caractristiques : Gamme de mesure : 0 20% LIE Dtecteur gaz gaine de ventilation compartiment turbine Caractristiques : Gamme de mesure : 0 20% LIE Dtecteur gaz gaine de ventilation compartiment turbine Caractristiques : Gamme de mesure : 0 20% LIE Thermostat de scurit chauffage compartiment gaz Caractristiques : Normal : NO Rglages : Ferm 100 +0/-16C Bouton d arrt d urgence situ l extrieur du compartiment des auxiliaires compartiment TG Caractristiques : Normal : NC Bouton d arrt d urgence situ l extrieur du compartiment des auxiliaires compartiment TG Caractristiques : Normal : NC Pressostat du circuit d air Caractristiques : Normal : NC Rglages : Ouvert la monte : 3 0,25 bar Pressostat pression basse entre air comprim filtre air TG Caractristiques : Normal : NO Rglages : Non rglable : ferm la monte : 6 0,5 bar | Ouvert la descente : 5,5 0,5 bar Manostat Caractristiques : Normal : NC Rglages : Ferm la descente : 1,03 0,05 bar | Non rglable : ouvert la monte : 2,41 0,05 bar Manostat Caractristiques : Normal : NC Rglages : Ferm la descente : 1,03 0,05 bar | Non rglable : ouvert la monte : 2,41 0,05 bar Manostat pression fuel amont vanne arrt fuel Caractristiques : Normal : NO Rglages : Non rglable : ferm la monte : 2,75 0,14 bar | Ouvert la descente : 2,41 0,07 bar Manostat diffrentiel filtre alimentation hydraulique Caractristiques : Normal : NC Rglages : Non rglable : ferm la descente : 2,75 1,03 bar | Ouvert la monte : 4,13 0,2 bar

0436

49HA-12

1658

ENCL-G

0426

5E-10

1113

ENCL-T

0426

5E-11

1113

ENCL-T

0494

63AF-31

E021/E0 48

VAN

0471

63CA-1

A040

FILT

0422

63FG-1

0991

GAS

0422

63FG-2

0991

GAS

0424

63FL-2

0992

ACCY

0434

63HF-1

0926

ACCY

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

13/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID

392A8431
Appareils MLI

14
Schma cblage

C
Safety Dsignation Manostat de pression basse alimentation huile HP Caractristiques : Normal : NO Rglages : Non rglable : ferm la monte : 100 3,1 bar | Ouvert la descente : 93 1,7 bar Presostat skid de nettoyage Caractristiques : Normal : NC Rglages : Ouvert la monte : 1 0,1 bar Manostat de pression diffrentielle filtre fuel principal Caractristiques : Normal : NC Rglages : Non rglable : ferm la descente : 1,1 0,07 bar | Ouvert la monte : 1,3 0,07 bar

TBFT-TMP-FR-GTE-0060 Rev : 001

0434

63HQ-1

0926

ACCY

0441

63KJ

E026

CLEAN

0424

63LF-7

0992

ACCY

0477

63PG-1

0991

GAS

Manostat sur pression dans l espace inter vannes VA13-1 et VA13-2 Caractristiques : Normal : NC Rglages : Non rglable : ferm la descente : 3,17 0,21 bar | Ouvert la monte : 3,45 0,14 bar Manostat sur air de balayage des injecteurs de combustible liquide Caractristiques : Normal : NO Rglages : Non rglable : ferm la monte : 6 0,3 bar | Ouvert la descente : 4,6 0,3 bar Manostat pression huile de lubrification Caractristiques : Normal : NO Rglages : Non rglable : ferm la monte : 3,1 0,14 bar | Ouvert la descente : 2,8 0,07 bar Manostat pression diffrentielle filtre huile principal Caractristiques : Normal : NC Rglages : Non rglable : ferm la descente : 0,9 0,2 bar | Ouvert la monte : 1,03 0,068 bar Manostat pression diffrentielle filtre huile principal Caractristiques : Normal : NC Rglages : Non rglable : ferm la descente : 0,9 0,2 bar | Ouvert la monte : 1,03 0,068 bar Manostat pression diffrentielle filtre convertisseur de couple Caractristiques : Normal : NC Rglages : Ouvert la monte : 1,5 0,2 bar Manostat pression huile de lubrification palier #2 alternateur Caractristiques : Normal : NO Rglages : Non rglable : ferm la monte : 0,62 0,035 bar | Ouvert la descente : 0,55 0,021 bar Pressostat diffrentiel entre l entre d air et les hottes pare-pluie Caractristiques : Normal : NC Rglages : Ouvert la monte : 3 0,2 mbar Pressostat diffrentiel entre l entre d air et les hottes pare-pluie Caractristiques : Normal : NC Rglages : Ouvert la monte : 3 0,2 mbar Pressostat diffrentiel admission d air TG Caractristiques : Normal : NC Rglages : Ouvert la monte : 21 0,5 mbar

0477

63PL-21

918T

TURB

0416

63QA-2

0926

ACCY

0416

63QQ-21

0940

ACCY

0416

63QQ-22

0940

ACCY

0416

63QQ-8

0916

ACCY

0416

63QT-2A

ALT.

GENE

0471

63TF-10A

A040

FILT

0471

63TF-10B

A040

FILT

0471

63TF-2A

A040

FILT

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

14/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID

392A8431
Appareils MLI

15
Schma cblage

C
Safety Dsignation Pressostat diffrentiel admission d air TG Caractristiques : Normal : NC Rglages : Ouvert la monte : 21 0,5 mbar Manostat de contrle de ventilation du corps turbine Caractristiques : Normal : NO Rglages : Ferm au dessus de 381 19 mm H2O Manostat de contrle de ventilation du corps turbine Caractristiques : Normal : NO Rglages : Ferm au dessus de 381 19 mm H2O Pressostat entre pompe injection d eau Caractristiques : Normal : NC Rglages : Ouvert la descente : -0,270 0,01 bar Pressostat sortie pompe injection d eau Caractristiques : Normal : NO Rglages : Ouvert la descente : 25 bar Pressostat diffrentiel filtre sortie pompe injection d eau Caractristiques : Normal : NC Rglages : Ouvert la monte : 1,03 0,1 bar Servovalve (bypass) pompe fuel Servovalve contrle gaz (VGC-1) Dtecteur de niveau sur bac principal 501BA Caractristiques : Normal : NO Rglages : Ouvert quand niveau bas Contrleur de niveau sur le bac auxiliaire Caractristiques : Normal : NO Rglages : Ouvert quand niveau bas Dtecteur de niveau pot de dtection fuites Caractristiques : Normal : NC Rglages : Ouverture au niveau haut Dtecteur de niveau pot de dtection fuites Caractristiques : Normal : NC Rglages : Ouverture au niveau trs haut Dtecteur de niveau pot de dtection fuites Caractristiques : Normal : NC Rglages : Ouverture au niveau trs haut

TBFT-TMP-FR-GTE-0060 Rev : 001

0471

63TF-2B

A040

FILT

0417

63TK-1

A053/A 132

ACCY

0417

63TK-2

A053/A 132

ACCY

0462

63WN-1

A035

WI

0462

63WN-2

A035

WI

0462 0424 0422 0494

63WN-3 65FP 65GC-1 71FA-31

A035 0533 0509 E021/E0 48 E021/E0 48

WI ACCY GAS VAN

0494

71FA-32

VAN

0424

71FF-4

969L

TURB

0424

71FF-5

969L

TURB

0424

71FF-6

969L

TURB

0416

71QH-1

1038

ACCY

Niveau haut cuve huile de lubrification Caractristiques : Normal : NC Rglages : Ouvert sur niveau haut. Voir schma huile de lubrification MLI 0416 pour rglage Dtecteur niveau bas huile de lubrification Caractristiques : Normal : NO Rglages : Ouverture sur niveau bas. Voir schma huile de lubrification MLI 0416 pour rglage Capteur de vitesse magntique diviseur de dbit Rglages : Entrefer : 0,23 0,025 mm Capteur de vitesse magntique diviseur de dbit Rglages : Entrefer : 0,23 0,025 mm Capteur de vitesse magntique diviseur de dbit Rglages : Entrefer : 0,23 0,025 mm Capteur de vitesse Rglages : Entrefer : 1,27 0,127 mm SIZE CAGE CODE DWG NO

0416

71QL-1

1038

ACCY

0424 0424 0424 0415

77FD-1 77FD-2 77FD-3 77HT-1

0910 0910 0910 0546

ACCY ACCY ACCY TURB

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

15/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0415 0415 0415 0415 0415

392A8431
Appareils 77HT-2 77HT-3 77NH-1 77NH-2 77NH-3 MLI 0546 0546 0546 0546 0546

16
Schma cblage TURB TURB TURB TURB TURB

C
Safety Dsignation Capteur de vitesse Rglages : Entrefer : 1,27 0,127 mm Capteur de vitesse Rglages : Entrefer : 1,27 0,127 mm Capteur de vitesse Rglages : Entrefer : 1,27 0,127 mm Capteur de vitesse Rglages : Entrefer : 1,27 0,127 mm Capteur de vitesse Rglages : Entrefer : 1,27 0,127 mm Capteur de phase, bout d arbre cot turbine Caractristiques : Sortie proximitor : 7,87 V/mm Rglages : Entrefer : 1,4 0,05 mm

TBFT-TMP-FR-GTE-0060 Rev : 001

0415

77RP-11

235A

TURB

0425 0436 0436 0421 0494 0494 0494 0424 0434 0436 0436 0416 0416 0416 0421

88AB-1 88BT-1 88BT-2 88CR-1 88FA-30 88FA-31 88FA-32 88FM 88HQ-1 88JS-1 88JS-2 88QA-1 88QE-1 88QV-1A 88TG-1

1047 1605 1605 0603 E021/E0 48 E021/E0 48 E021/E0 48 0613 0628 1659 1659 1006 1007 A098 0538 1233/A 132 1233/A 132

ACCY ENCL-T ENCL-T ACCY VAN VAN VAN ACCY ACCY ENCL-WI ENCL-WI ACCY ACCY MIST ACCY

Moteur compresseur de dmarrage air atomisation Caractristiques : 15 kW | 3000 tr/min | 27,5A | 50 hz | 400 VAC Moteur lectrique ventilateur refroidissement compartiment TG Caractristiques : 37 kW | - tr/min | 50 hz | 400 VAC Moteur lectrique ventilateur refroidissement compartiment TG Caractristiques : 37 kW | - tr/min | 50 hz | 400 VAC Moteur lectrique de lancement Caractristiques : 1000 kW | 3000 tr/min | 50 hz | 6,6 kV Moteur lectrique de la pompe PFA-30 Caractristiques : 0,46 kW | 1500 tr/min | 50 hz | 230 VAC Moteur lectrique de la pompe PFA-31 Caractristiques : 0,37 kW | 1380 tr/min | 50 hz | 400 VAC Moteur lectrique de la pompe PFA-32 Caractristiques : 0,37 kW | 1380 tr/min | 50 hz | 400 VAC Moteur lectrique dmarrage rpartiteur de dbit combustible liquide Caractristiques : 0,37 kW | 1400 tr/min | 50 hz | 400 VAC Moto-pompe auxiliaire huile HP Caractristiques : 15 kW | 1500 tr/min | 28,2A | 50 hz | 400 VAC Moteur lectrique ventilation enceinte acoustique skid injection d eau Caractristiques : 0,37 kW | 1500 tr/min | 50 hz | 400 VAC Moteur lectrique ventilation enceinte acoustique skid injection d eau Caractristiques : 0,37 kW | 1500 tr/min | 50 hz | 400 VAC Moteur lectrique de la pompe huile auxiliaire Caractristiques : 90 kW | 3000 tr/min | 149,5A | 50 hz | 400 VAC Moteur lectrique de la pompe huile de secours Caractristiques : 9 kW | 1750 tr/min | 89A | 125 VDC Moteur lectrique du dshuileur Caractristiques : 18,5 kW | 3000 tr/min | 32,8A | 50 hz | 400 VAC Moteur lectrique de virage Caractristiques : 30 kW | 750 tr/min | 50 hz | 400 VAC Ventilateur centrifuge + moteur lectrique groupe moto ventilateur refroidissement corps TG Caractristiques : 45 kW | 3000 tr/min | 79A | 50 hz | 400 VAC Ventilateur centrifuge + moteur lectrique groupe moto ventilateur refroidissement corps TG Caractristiques : 45 kW | 3000 tr/min | 79A | 50 hz | 400 VAC

0417

88TK-1

ACCY

0417

88TK-2

ACCY

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

16/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0421 0436 0436 0436 0436 0462 0422 0469

392A8431
Appareils 88TM-1 88VG-1 88VG-2 88VL-1 88VL-2 88WN-1 90SR-1 90TV-1 MLI 0605 1605 1605 1658 1658 A035 0507 0548

17
Schma cblage ACCY ENCL-T ENCL-T ENCL-G ENCL-G WI GAS TURB

C
Safety Dsignation Moteur convertisseur de couple Caractristiques : 1,5 kW | 3000 tr/min | 50 hz | 400 VAC

TBFT-TMP-FR-GTE-0060 Rev : 001

Moteur lectrique ventilateur refroidissement compartiment puissance Caractristiques : 18,5 kW | 1500 tr/min | 50 hz | 400 VAC Moteur lectrique ventilateur refroidissement compartiment puissance Caractristiques : 18,5 kW | 1500 tr/min | 50 hz | 400 VAC Moteur lectrique ventilateur compartiment gaz Caractristiques : 4 kW | 1500 tr/min | 50 hz | 400 VAC Moteur lectrique ventilateur compartiment gaz Caractristiques : 4 kW | 1500 tr/min | 50 hz | 400 VAC Moteur de la pompe injection d eau Caractristiques : 55 kW | 3000 tr/min | 92.5 A | 50 hz | 400 VAC Servovalve arrt et rgulation gaz Servovalve actionneur IGV compresseur Rgulateur lectro-pneumatique Rglages : 04 0,20 mA for 0 bar 20 0,20 mA for 2,6 bar Contrleur de dbit d air (anmomtre) de ventilation compartiment turbine Caractristiques : 04 - 20 mA pour 0,5 - 30 m/s Rglages : ventilateur l arrt sans dbit d air : 4 -0/+1 mA ventilateur en service et portes fermes : x1 mA, rgler la constante du speedtronic une valeur quivalente { [60% * (x1 - 4) ] + 4 mA } Contrleur de dbit d air (anmomtre) de ventilation compartiment turbine Caractristiques : 04 - 20 mA pour 0,5 - 30 m/s Rglages : ventilateur l arrt sans dbit d air : 4 -0/+1 mA ventilateur en service et portes fermes : x1 mA, rgler la constante du speedtronic une valeur quivalente { [60% * (x1 - 4) ] + 4 mA } Contrleur de dbit d air (anmomtre) de ventilation compartiment turbine Caractristiques : 04 - 20 mA pour 0,5 - 30 m/s Rglages : ventilateur l arrt sans dbit d air : 4 -0/+1 mA ventilateur en service et portes fermes : x1 mA, rgler la constante du speedtronic une valeur quivalente { [60% * (x1 - 4) ] + 4 mA } Transformateur pour bougie d allumage 95SP-13 Caractristiques : 0,15 kVA | 50 hz | 15 kV | 230 VAC Transformateur pour bougie d allumage 95SP-14 Caractristiques : 0,15 kVA | 50 hz | 15 kV | 230 VAC Bougie d allumage chambre de combustion n13 Bougie d allumage chambre de combustion n14 Contrleur de dbit d air (anmomtre) de ventilation compartiment gaz Caractristiques : 04 - 20 mA pour 0,5 - 30 m/s Rglages : ventilateur l arrt sans dbit d air : 4 -0/+1 mA ventilateur en service et portes fermes : x1 mA, rgler la constante du speedtronic une valeur quivalente { [60% * (x1 - 4) ] + 4 mA } Contrleur de dbit d air (anmomtre) de ventilation compartiment gaz Caractristiques : 04 - 20 mA pour 0,5 - 30 m/s Rglages : ventilateur l arrt sans dbit d air : 4 -0/+1 mA ventilateur en service et portes fermes : x1 mA, rgler la constante du speedtronic une valeur quivalente { [60% * (x1 - 4) ] + 4 mA } Contrleur de dbit d air (anmomtre) de ventilation compartiment gaz Caractristiques : 04 - 20 mA pour 0,5 - 30 m/s Rglages : ventilateur l arrt sans dbit d air : 4 -0/+1 mA ventilateur en service et portes fermes : x1 mA, rgler la constante du speedtronic une valeur quivalente { [60% * (x1 - 4) ] + 4 mA } SIZE CAGE CODE DWG NO

0462

90WN-1

A035

WI

0436

95BT-1

1605

ENCL-T

0436

95BT-2

1605

ENCL-T

0436

95BT-3

1605

ENCL-T

0415 0415 0415 0415

95SG-13 95SG-14 95SP-13 95SP-14

1213 1213 1214 1214

TURB TURB TURB TURB

0436

95VL-1

1658

ENCL-G

0436

95VL-2

1658

ENCL-G

0436

95VL-3

1658

ENCL-G

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

17/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID

392A8431
Appareils MLI

18
Schma cblage

C
Safety Dsignation Transmetteur de pression relative du manifold air ato Rglages : 04 0,05 mA pour -1 bar 20 0,1 mA pour 35 bar Transmetteur de pression relative du manifold air ato Rglages : 04 0,05 mA pour -1 bar 20 0,1 mA pour 35 bar Transmetteur de pression relative du manifold air ato Rglages : 04 0,05 mA pour -1 bar 20 0,1 mA pour 35 bar

TBFT-TMP-FR-GTE-0060 Rev : 001

0425

96AA-4A

557T

TURB

0425

96AA-4B

557T

TURB

0425

96AA-4C

557T

TURB

0425

96AD-1

0926

ACCY

Transmetteur de la pression diffrentielle du compresseur principal d air d atomisation Rglages : 04 0,02 mA pour 0 bar 20 0,1 mA pour 6 bar Transmetteur de pression Rglages : 04 0,02 mA pour 0,745 bar abs 20 0,10 mA pour 1,250 bar abs Transmetteur de pression Rglages : 04 0,02 mA pour 0,745 bar abs 20 0,10 mA pour 1,250 bar abs Transmetteur de pression Rglages : 04 0,02 mA pour 0,745 bar abs 20 0,10 mA pour 1,250 bar abs Transmetteur de pression diffrentielle entre l entre d air et la tulipe d admission turbine Rglages : 04 0,02 mA pour 0,000 bar 20 0,10 mA pour 0,345 bar Transmetteur de pression sortie compresseur Rglages : 04 0,05 mA pour 0 bar 20 0,05 mA pour 21 bar Transmetteur de pression sortie compresseur Rglages : 04 0,05 mA pour 0 bar 20 0,05 mA pour 21 bar Transmetteur de pression sortie compresseur Rglages : 04 0,05 mA pour 0 bar 20 0,05 mA pour 21 bar Transmetteur de pression diffrentielle entre l entre d air de la turbine et l atmosphre Rglages : 04 0,02 mA pour 0 mbar 20 0,10 mA pour 27,4 mbar Transmetteur de pression entre module gaz Rglages : 04 0,05 mA pour 0 bar 20 0,1 mA pour 34,5 bar Transmetteur de pression gaz inter-vanne Rglages : 04 0,05 mA pour 0 bar 20 0,1 mA pour 34,5 bar SIZE CAGE CODE DWG NO

0492

96AP-1A

0559

ACCY

0492

96AP-1B

0559

ACCY

0492

96AP-1C

0559

ACCY

0492

96BD-1

0559

ACCY

0417

96CD-1A

0557

ACCY

0417

96CD-1B

0557

ACCY

0417

96CD-1C

0557

ACCY

0492

96CS-1

0559

ACCY

0422

96FG-1

0991

GAS

0422

96FG-2A

0991

GAS

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

18/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID

392A8431
Appareils MLI

19
Schma cblage

C
Safety Dsignation Transmetteur de pression gaz inter-vanne Rglages : 04 0,05 mA pour 0 bar 20 0,1 mA pour 34,5 bar Transmetteur de pression gaz inter-vanne Rglages : 04 0,05 mA pour 0 bar 20 0,1 mA pour 34,5 bar

TBFT-TMP-FR-GTE-0060 Rev : 001

0422

96FG-2B

0991

GAS

0422

96FG-2C

0991

GAS

0422

96GC-1,2

0509

GAS

Transmetteur de position linaire diffrentiel (LVDT) vanne contrle gaz (VGC-1) Rglages : 0,7 0,1 V = 0% d ouverture 3,5 0,5 V = 100% d ouverture Transmetteur de pression huile de lubrification avant VPR-2 Rglages : 04 0,05 mA pour 0 bar 20 0,1 mA pour 7 bar Transmetteur de pression sortie pompe d urgence Rglages : 04 0,05 mA pour 0 bar 20 0,1 mA pour 2 bar Transmetteur pression huile de graissage palier #2 alternateur Rglages : 04 0,05 mA pour 0 bar 20 0,1 mA pour 1,72 bar Transmetteur pression d air dans la cuve Rglages : 04 0,05 mA pour 0 bar 20 0,1 mA pour -15 mbarg Transmetteur de point de rose et de temprature Rglages : Sortie 1 : 04 0,05 mA pour -50C 20 0,05 mA pour +50C Sortie 2 : 04 0,05 mA pour 0% HR 20 0,05 mA pour 100 % HR Transmetteur de position linaire diffrentiel (LVDT) vanne stop ratio gaz (VSR-1) Rglages : 0,7 0,01 VAC pour 0 mm Transmetteur de pression diffrentielle entre atmosphre et le plenum air propre du filtre (aprs tage de filtration) Rglages : 04 0,05 mA pour 0 mmH2O 20 0,1 mA pour 254 mmH2O Transmetteur de pression diffrentielle entre l entre d air et les hottes pare-pluie Rglages : 04 0,05 mA pour 0 mmH2O 20 0,1 mA pour 254 mmH2O Transmetteur de position aubes variables convertisseur de couple Rglages : 04 0,05 mA pour 0 tr de volant (pleine chelle 0-242 tr) 20 0,05 mA pour 242 tr de volant (pleine chelle 0-242 tr) Transmetteur de position linaire diffrentiel (LVDT), actionneur aubes variables entre compresseur Rglages : 0,7 0,01 VAC pour 34 angle IGV Transmetteur de position linaire diffrentiel (LVDT), actionneur aubes variables entre compresseur Rglages : 0,7 0,01 VAC pour 34 angle IGV SIZE CAGE CODE DWG NO

0416

96QA-2

0926

ACCY

0416

96QE-2

0926

ACCY

0416

96QT-2B

ALT.

GENE

0416

96QV-1

0557

ACCY

0471

96RH

A040

FILT

0422

96SR-1,2

0507

GAS

0471

96TF-1

A040

FILT

0471

96TF-10

A040

FILT

0421

96TM-1

0605

ACCY

0469

96TV-1

0548

TURB

0469

96TV-2

0548

TURB

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

19/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0415

392A8431
Appareils MLI

20
Schma cblage TURB

C
Safety Dsignation Capteur de vibration Caractristiques : Sortie proximitor : 7,87 V/mm Rglages : Entrefer : 1,4 0,05 mm Capteur de vibration Caractristiques : Sortie proximitor : 7,87 V/mm Rglages : Entrefer : 1,4 0,05 mm Transmetteur de dbit massique gaz Rglages : 04 0,05 mA pour 0 kg/s 20 0,1 mA pour 10 kg/s Transmetteur de dbit Rglages : 04 0,2 mA pour 0 m3/h 20 0,2 mA pour 20,4 0,1 m3/h Transmetteur de dbit Rglages : 04 0,2 mA pour 0 m3/h 20 0,2 mA pour 20,4 0,1 m3/h Transmetteur de dbit Rglages : 04 0,2 mA pour 0 m3/h 20 0,2 mA pour 20,4 0,1 m3/h

TBFT-TMP-FR-GTE-0060 Rev : 001

96VC-11

235A

0415

96VC-12

235A

TURB

0422

96VM-1

0639

OTHER

0462

96WF-1

A035

WI

0462

96WF-2

A035

WI

0462

96WF-3

A035

WI

0425 0425

AAT-1A AAT-2A

637T 637T

TURB TURB

Thermocouple sur air en aval du rfrigrant d air d atomisation Caractristiques : Type K Thermocouple sur air en aval du rfrigrant d air d atomisation Caractristiques : Type K Accumulateur sur huile de contrle Caractristiques : 17,8 l | Azote Rglages : 51,7 1 bar Accumulateur sur huile de contrle Caractristiques : 17,8 l | Azote Rglages : 51,7 1 bar Thermocouple compartiment auxiliaire Caractristiques : Type K Thermocouple compartiment gaz Caractristiques : Type K Temprature compartiment puissance Caractristiques : Platine PT100 | 100 Ohm 0C | -50 260 C | 0,385 Ohm/C Temprature compartiment turbine Caractristiques : Platine PT100 | 100 Ohm 0C | -50 260 C | 0,385 Ohm/C Thermocouple : compartiment turbine Caractristiques : Type K Thermocouple : compartiment turbine Caractristiques : Type K Temprature compartiment injection d eau compartiment injection d eau Caractristiques : Type K Thermocouple dual temprature coussinet du palier n1 Caractristiques : Type K Thermocouple dual temprature coussinet du palier n1 Caractristiques : Type K Thermocouple dual temprature coussinet du palier n2 Caractristiques : Type K

0434

AH1-1

0908

N/A

0422

AH1-3

0991

N/A

0436 0436 0436 0436 0436 0436 0436 0415 0415 0415

AT-AC-1 AT-AC-11 AT-LC-1 AT-TC-1 AT-TC-2 AT-TC-3 AT-WI-1 BT-J1-1A,1B BT-J1-2A,2B BT-J2-1A,1B

1113 1195 637T 637T 1113 1113 1659 235A 235A 235B

ENCL-T ENCL-G TURB TURB ENCL-T ENCL-T ENCL-WI TURB TURB TURB

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

20/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0415 0415 0415 0415 0415 0415 0415 0425 0425 0415 0415 0415 0415 0492 0421 0421 0421 0421 0421 0421 0477 0425 0417 0417 0462 0441

392A8431
Appareils BT-J2-2A,2B BT-J3-1A,1B BT-J3-2A,2B BT-TA1-4A,4B BT-TA1-8A,8B BT-TI1-1A,1B BT-TI1-6A,6B CA1 CA2 CT-DA-1 CT-DA-2 CT-IF-1 CT-IF-2 CT-IF-3/R ET-CRS-11/R ET-CRS-12/R ET-CRS-21/R ET-CRS-22/R ET-CRS-31/R ET-CRS-32/R FA3-1 FA4-1 FA6 FA7 FA8-2 FAKJ-1 MLI 235B 235C 235C 235A 235A 235A 235A 0607 1047 637T 637T 637T 637T 637T 0603 0603 0603 0603 0603 0603 918T 0983 0909 0931 A035 E026

21
Schma cblage TURB TURB TURB TURB TURB TURB TURB N/A N/A TURB TURB TURB TURB TURB ACCY ACCY ACCY ACCY ACCY ACCY N/A N/A N/A N/A N/A N/A

C
Safety Dsignation Thermocouple dual temprature coussinet du palier n2 Caractristiques : Type K Thermocouple dual temprature coussinet du palier n3 Caractristiques : Type K Thermocouple dual temprature coussinet du palier n3 Caractristiques : Type K

TBFT-TMP-FR-GTE-0060 Rev : 001

Thermocouple dual temprature patin n4 de la bute du palier n1 Caractristiques : Type K Thermocouple dual temprature patin n8 de la bute du palier n1 Caractristiques : Type K Thermocouple dual temprature patin n1 de la contre bute du palier n1 Caractristiques : Type K Thermocouple dual temprature patin n6 de la contre bute du palier n1 Caractristiques : Type K Compresseur principal d air d atomisation Caractristiques : Centrifuge | 2,7 kg/s |Vitesse de l arbre rducteur : 6600 tr/min Compresseur d air d atomisation de dmarrage Caractristiques : Volumtrique | 510 m3/h | 4000 tr/min Thermocouple temprature air sortie du compresseur Caractristiques : Type K Thermocouple temprature air sortie du compresseur Caractristiques : Type K Thermocouple temprature air entre du compresseur Caractristiques : Type K Thermocouple temprature air entre du compresseur Caractristiques : Type K Dtecteur de temprature rsistance Caractristiques : Platine PT100 | 100 Ohm 0C | -50 260 C | 0,385 Ohm/C Capteur de temprature 1 stator Ph1 du moteur de lancement Caractristiques : Platine PT100 | 100 Ohm 0C | -50 260 C | 0,385 Ohm/C Capteur de temprature 2 stator Ph1 du moteur de lancement Caractristiques : Platine PT100 | 100 Ohm 0C | -50 260 C | 0,385 Ohm/C Capteur de temprature 1 stator Ph2 du moteur de lancement Caractristiques : Platine PT100 | 100 Ohm 0C | -50 260 C | 0,385 Ohm/C Capteur de temprature 2 stator Ph2 du moteur de lancement Caractristiques : Platine PT100 | 100 Ohm 0C | -50 260 C | 0,385 Ohm/C Capteur de temprature 1 stator Ph3 du moteur de lancement Caractristiques : Platine PT100 | 100 Ohm 0C | -50 260 C | 0,385 Ohm/C Capteur de temprature 2 stator Ph3 du moteur de lancement Caractristiques : Platine PT100 | 100 Ohm 0C | -50 260 C | 0,385 Ohm/C Filtre sur air de balayage du combustible liquide Caractristiques : 5 m Filtre sur air de commande des systmes d air d atomisation et d air de balayage Caractristiques : 5 m Filtre sur air de commande du systme anti-pompage Sparateur d humidit de l air extraction 5me tage Filtre air injection d eau Caractristiques : 5 m Filtre pressostat skid de nettoyage SIZE CAGE CODE DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

21/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0441 0424

392A8431
Appareils FAKJ-2 FD1-1 MLI E026 0613

22
Schma cblage N/A N/A

C
Safety Filtre tamis Dsignation

TBFT-TMP-FR-GTE-0060 Rev : 001

Rpartiteur de dbit Caractristiques : type linaire, 7 lments double pompes | 883 l/min 1650 tr/min | 50 hz Filtre fuel HP Caractristiques : Bta 40 = 75 Filtre fuel HP Caractristiques : Bta 40 = 75 Filtre en amont des pompes Caractristiques : Mesh = 0.91 mm Filtre alimentation huile HP Caractristiques : Bta 3 > 200 Filtre alimentation huile HP Caractristiques : Bta 3 > 200 Filtre hydraulique servo vanne fuel liquide (contrle) Caractristiques : 40 m Filtre alimentation bloc de commande hydraulique IGV Caractristiques : Bta 15 = 75 Filtre hydraulique du circuit d alimentation de la servo-valve de la VSR Caractristiques : 15 m abs Filtre hydraulique alimentation hydraulique vanne control gaz (VGC) Caractristiques : 15 m abs Dbimtre injection d eau Caractristiques : 1,4 m3/h | Facteur nominal K : 343,5 impulsions / l | 20,4 m3/h Filtre haute pression Caractristiques : Bta 13 = 75 Filtre Y amont pompe d injection d eau Caractristiques : Media filtrant 800m Filtre conique aval dbimtre Caractristiques : Media filtrant 150m Convertisseur de couple et inverseur Ensemble actionneur systme aubes variables entre compresseur Caractristiques : Course vrin de 31,5 0,5 87,75 0,25 Rfrigrant de l air d atomisation en amont du compresseur d air d atomisation Filtre huile Caractristiques : Bta 40 = 75 Filtre huile Caractristiques : Bta 40 = 75 Rfrigrant huile de graissage Rfrigrant huile de graissage Thermocouple retour huile palier #1 Caractristiques : Type K Thermocouple retour huile palier #2 Caractristiques : Type K Thermocouple retour huile palier #3 Caractristiques : Type K Thermocouple retour huile butes palier #1 Caractristiques : Type K

0424 0424 0494 0434 0434 0424 0469 0422 0422 0462 0462 0462 0462 0421 0469 0425 0416 0416 0416 0416 0416 0416 0416 0416

FF2-1 FF2-2 FF31-1 FH2-1 FH2-2 FH3 FH6-1 FH7-1 FH8-1 FM1-1 FW1-1 FW1-2 FW1-3 HM-1 HM3-1 HX1-1 LOF1-1 LOF1-2 LOHX-1 LOHX-2 LT-B1D-1 LT-B2D-1 LT-B3D-1 LT-BT1D-1

1014 1014 E021/E0 48 1051 1051 0992 0548 0507 0509 A035 A035 A035 A035 0605 0548 1003 1010 1010 1001 1001 637T 637T 637T 637T

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A TURB TURB TURB TURB

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

22/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0416 0416 0416 0416 0416 0416 0416 0422 0424 0494 0494 0494 0434 0434 0416 0416

392A8431
Appareils LT-G1D-1 LT-G2D-1 LT-OT-1 LT-OT-2 LT-TH-1 LT-TH-2 LT-TH-3 MG1 PF1 PFA-30 PFA-31 PFA-32 PH1 PH2 PQ1-1 PQ2-1 MLI ALT. ALT. 1218 1218 637A 637A 637A 0512 0611 E021/E0 48 E021/E0 48 E021/E0 48 0627 0628 0601 1007 E021/E0 48 A035 1104 1113 1113 1113 1195 1195 1104

23
Schma cblage GENE GENE TURB TURB ACCY ACCY ACCY N/A ACCY N/A N/A N/A N/A N/A N/A N/A

C
Safety Dsignation

TBFT-TMP-FR-GTE-0060 Rev : 001

Thermocouple retour d huile palier #1 alternateur et rducteur Caractristiques : Type K Thermocouple retour d huile palier #2 alternateur et rducteur Caractristiques : Type K Dtecteur de temprature rsistance cuve huile Caractristiques : Platine PT100 | 100 Ohm 0C | -50 260 C | 0,385 Ohm/C Dtecteur de temprature rsistance cuve huile Caractristiques : Platine PT100 | 100 Ohm 0C | -50 260 C | 0,385 Ohm/C Thermocouple huile de lubrification collecteur turbine Caractristiques : Type K Thermocouple huile de lubrification collecteur turbine Caractristiques : Type K Thermocouple huile de lubrification collecteur turbine Caractristiques : Type K Injecteur combustible gaz Pompe principale combustible liquide Caractristiques : Pompe volumtrique vis | 2924 tr/min | 68,9 bar | 870,5 l/min Pompe de chargement Caractristiques : Volumtrique | 25 l/min Pompe doseuse Caractristiques : Volumtrique piston | 1500 tr/min | 10 bar | Dbit dfinir Pompe doseuse Caractristiques : Volumtrique piston | 1500 tr/min | 10 bar | Dbit dfinir Pompe hydraulique principale Caractristiques : Type volumtrique dbit variable | 1422 tr/min | 105 bar | 65 l/min Pompe auxiliaire huile HP Caractristiques : Volumtrique | 1450 tr/min | 105 bar | 45,4 l/min Pompe huile de graissage principale Caractristiques : Type volumtrique | 6,89 bar | 3000 l/min Pompe huile de secours Caractristiques : Type centrifuge | 1,37 bar | 1596 l/min Respirateur du bac 501BA Caractristiques : Normal : NC Rglages : Surpression : 0,15 bar ; Vide : 0,01 bar Groupe moto-pompe injection d eau Caractristiques : Centrifuge | 12263 rpm | 33 bar (480 psi) | 26,6 m3/h Avertisseur lumineux compartiment auxiliaire Caractristiques : 0,015 | 50 hz | 230 UPS Avertisseur incendie compartiment auxiliaire Caractristiques : Alarme lumineuse | 24 VDC Avertisseur incendie compartiment TG Caractristiques : Alarme lumineuse | 24 VDC Avertisseur incendie compartiment TG Caractristiques : Alarme sonore et lumineuse | 24 VDC Avertisseur incendie compartiment gaz Caractristiques : Alarme lumineuse | 24 VDC Avertisseur incendie compartiment gaz Caractristiques : Alarme sonore et lumineuse | 24 VDC Avertisseur lumineux compartiment auxiliaire Caractristiques : 0,015 | 50 hz | 230 UPS SIZE CAGE CODE DWG NO

0494

PSV-31

N/A

0462 0426 0426 0426 0426 0426 0426 0426

PW1-1 SLI-1 SLI-1A SLI-1B SLI-1C SLI-1D SLI-1E SLI-2

N/A ACCY ENCL-T ENCL-T ENCL-T ENCL-G ENCL-G ACCY

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

23/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0426 0426 0426 0426 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415

392A8431
Appareils SLI-2B SLI-2C SLI-2E SLI-3C TT-IB-1 TT-IB-2 TT-IB-3 TT-WS1AO-1 TT-WS1AO-2 TT-WS1FI-1 TT-WS1FI-2 TT-WS2AO-1 TT-WS2AO-2 TT-WS2FO-1 TT-WS2FO-2 TT-WS3AO-1 TT-WS3AO-2 TT-WS3FO-1 TT-WS3FO-2 TT-XD-1 TT-XD-10 TT-XD-11 TT-XD-12 TT-XD-13 TT-XD-14 MLI 1113 1113 1195 1113 637T 637T 637T 637T 637T 637T 637T 637T 637T 637T 637T 637T 637T 637T 637T 0623 0623 0623 0623 0623 0623

24
Schma cblage ENCL-T ENCL-T ENCL-G ENCL-T TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB

C
Safety Dsignation Avertisseur incendie compartiment TG Caractristiques : Alarme lumineuse | 24 VDC Avertisseur incendie compartiment TG Caractristiques : Alarme sonore et lumineuse | 24 VDC Avertisseur incendie compartiment gaz Caractristiques : Alarme sonore et lumineuse | 24 VDC Avertisseur incendie compartiment puissance Caractristiques : Alarme sonore et lumineuse | 24 VDC Thermocouple temprature tunnel chappement Caractristiques : Type K Thermocouple temprature tunnel chappement Caractristiques : Type K Thermocouple temprature tunnel chappement Caractristiques : Type K

TBFT-TMP-FR-GTE-0060 Rev : 001

Thermocouple temprature entre roue turbine position extrieure aprs premire roue Caractristiques : Type K Thermocouple temprature entre roue turbine position extrieure aprs premire roue Caractristiques : Type K Thermocouple temprature entre roue turbine position intrieure avant premire roue Caractristiques : Type K Thermocouple temprature entre roue turbine position intrieure avant premire roue Caractristiques : Type K Thermocouple temprature entre roue turbine position extrieure aprs deuxime roue Caractristiques : Type K Thermocouple temprature entre roue turbine position extrieure aprs deuxime roue Caractristiques : Type K Thermocouple temprature entre roue turbine position extrieure avant deuxime roue Caractristiques : Type K Thermocouple temprature entre roue turbine position extrieure avant deuxime roue Caractristiques : Type K Thermocouple temprature entre roue turbine position extrieure aprs troisime roue Caractristiques : Type K Thermocouple temprature entre roue turbine position extrieure aprs troisime roue Caractristiques : Type K Thermocouple temprature entre roue turbine position extrieure avant troisime roue Caractristiques : Type K Thermocouple temprature entre roue turbine position extrieure avant troisime roue Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K SIZE CAGE CODE DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

24/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415 0415

392A8431
Appareils TT-XD-15 TT-XD-16 TT-XD-17 TT-XD-18 TT-XD-19 TT-XD-2 TT-XD-20 TT-XD-21 TT-XD-22 TT-XD-23 TT-XD-24 TT-XD-3 TT-XD-4 TT-XD-5 TT-XD-6 TT-XD-7 TT-XD-8 TT-XD-9 MLI 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623

25
Schma cblage TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB TURB

C
Safety Dsignation Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Thermocouple temprature d chappement de la turbine Caractristiques : Type K Vanne d air de balayage du circuit gaz Caractristiques : Normal : NC Rglages : Temps d ouverture doit tre 30 5 secondes. Temps de fermeture doit tre 10 secondes au maximum.

TBFT-TMP-FR-GTE-0060 Rev : 001

0477

VA13-1

0991

N/A

0477

VA13-2

0991

N/A

Vanne d air de balayage du circuit gaz Caractristiques : Normal : NC Rglages : Le temps d ouverture de VA13-2 doit tre infrieur celui de la VA13-1 Vanne purge faux dpart Caractristiques : Normal : FO Vanne purge faux dpart Caractristiques : Normal : FO Vanne purge faux dpart Caractristiques : Normal : FO

0442 0442 0442

VA17-1 VA17-2 VA17-5

1026 1026 1026

N/A N/A N/A

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

25/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0425 0477 0417 0417

392A8431
Appareils VA18-1 VA19-1 VA2-1 VA2-2 MLI 1070 918T 1022 1022

26
Schma cblage N/A N/A N/A N/A

C
Safety Dsignation Vanne d ajustement de la pression d air d atomisation Caractristiques : Normal : NC Vanne d air de balayage du circuit de combustible liquide Caractristiques : Normal : C vers L ouvert ; U ferm Vanne anti-pompage Caractristiques : Normal : NO Vanne anti-pompage Caractristiques : Normal : NO

TBFT-TMP-FR-GTE-0060 Rev : 001

0425

VA22-1

0922

N/A

Vanne type papillon pour isolement entre d air du compresseur d air d atomisation CA2 Caractristiques : Normal : NO Vanne anti-pompage Caractristiques : Normal : NO Vanne anti-pompage Caractristiques : Normal : NO Vanne pneumatique de dpressurisation rapide pour vanne de balayage gaz VA13-1 Caractristiques : Sous pression : 1 vers 2 ouvert et vent 3 ferm Hors pression : 2 ouvert vers l vent 3 Vanne pneumatique de dpressurisation rapide pour vanne de balayage gaz VA13-2 Caractristiques : Sous pression : 1 vers 2 ouvert et vent 3 ferm Hors pression : 2 ouvert vers l vent 3 Vanne pneumatique Caractristiques : Normal : NO Vanne pneumatique Caractristiques : Normal : NC Vanne pneumatique Caractristiques : Normal : NO Purge d air sur circuit hydraulique principal Purge air sur circuit hydraulique auxiliaire Vanne de drivation de contrle dbit fuel Caractristiques : Course = 28,57 mm | Normal : NO Vanne de rgulation d injection d eau Caractristiques : Normal : NC Clapet anti-retour Caractristiques : Normal : NC Clapet anti-retour Caractristiques : Normal : NC Clapet anti-retour Caractristiques : Normal : NC Clapet anti-retour sur injecteur pour combustible fuel Caractristiques : Normal : NC Rglages : Tarage : 8,27 0,34 bar Clapet rglable dshuileur Caractristiques : Normal : NC Rglages : commence s ouvrir -100 10 mm H2O FSNL Clapet anti-retour sur air de balayage des injecteurs primaires de combustible liquide Caractristiques : Normal : NC Rglages : Pression d ouverture : Minimum 0,07 bar

0417 0417

VA2-3 VA2-4

1022 1022

N/A N/A

0477

VA36-1

0991

N/A

0477

VA36-2

0991

N/A

0494 0494 0494 0434 0434 0424 0462 0462 0462 0462

VA99-31 VA99-32 VA99-33 VAB1 VAB2 VC3 VC4-1 VCK100 VCK110 VCK111

E021/E0 48 E021/E0 48 E021/E0 48 0947 0947 0516 A035 A035 A035 A035

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

0424

VCK1-1T14

0961

N/A

0416

VCK20-13

A098

N/A

0477

VCK2-1T14

918T

N/A

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

26/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0434

392A8431
Appareils MLI

27
Schma cblage N/A

C
Safety Dsignation Clapet anti-retour pompe principale Caractristiques : Normal : NC Rglages : Seuil = 1,5 0,1 bar Clapet anti-retour pompe auxiliaire Caractristiques : Normal : NC Rglages : Seuil = 1,5 0,1 bar Clapet circuit air refroidissement corps turbine Caractristiques : Normal : NC Rglages : pression d ouverture : 7 mbar (non-rglable) Clapet circuit air refroidissement corps turbine Caractristiques : Normal : NC Rglages : pression d ouverture : 7 mbar (non-rglable) Vanne de contrle gaz primaire Caractristiques : Course maxi = 38,1 mm | Normal : NC Vanne slection pression injecteur fuel liquide Vanne de dclenchement hydraulique IGV Vanne de dclenchement hydraulique IGV Vanne de dclenchement hydraulique vanne VSR-1 Caractristiques : Normal : NC Vanne de dclenchement hydraulique vanne VGC-1 Caractristiques : Normal : NC Dbitmtre massique effet coriolis Vanne transfert pour filtre huile HP Vanne multiport Caractristiques : Normal : NC

TBFT-TMP-FR-GTE-0060 Rev : 001

VCK3-1

0947

0434

VCK3-2

0947

N/A

0417

VCK7-1

A053

N/A

0417

VCK7-2

A053

N/A

0422 0424 0469 0469 0422 0422 0422 0434 0424

VGC-1 VH17-1 VH3-1A VH3-1B VH5-1 VH5-2 VM-1 VM4 VP-1

0509 0992 0548 0548 0507 0509 0639 1051 0961

GAS N/A N/A N/A GAS GAS N/A N/A N/A

0416

VPR2-1

1023

N/A

Vanne de rgulation pression alimentation huile de lubrification Caractristiques : Normal : NC Rglages : 1,72 +0,13/-0 bar Filtre rgulateur Caractristiques : Normal : NO Rglages : 4 0,35 bar Compensateur de pression pompe hydraulique Rglages : 103,4 1,37 bar Filtre dtendeur d air de commande de la vanne d air de balayage du combustible gazeux Rglages : 2,3 +0/-0,2 bar Filtre dtendeur d air de commande de la vanne d air de balayage du combustible gazeux Rglages : 2,3 +0/-0,2 bar Filtre dtendeur d air de commande de la vanne d air de balayage fuel liquide Rglages : 3,27 +1,7/-0 bar Filtre dtendeur vanne de contrle injection d eau (partie de VC4-1) Rglages : 2,6 0,1 bar Filtre dtendeur vanne d arrt injection d eau (partie de VS2-1) Rglages : 6,2 0,1 bar Filtre dtendeur vanne d arrt injection d eau (partie de VS2-2) Rglages : 6,2 0,1 bar Vanne de rgulation de pression d air instrumentation de la VA22-1 Rglages : 3,79 0,13 bar (55 2 psi)

0494

VPR30-31

E021/E0 48 0627

N/A

0434

VPR3-1

N/A

0477

VPR44-1

0991

N/A

0477

VPR44-2

0991

N/A

0477 0462 0462 0462 0425

VPR54-1 VPR62-1 VPR62-11 VPR62-13 VPR68-1

918T A035 A035 A035 0922

N/A N/A N/A N/A N/A

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

27/28

Doc. Source : TBFT-ISP-FR-GTE-0020

SIZE

DWG NO

SH

REV

A4
MLI PID 0462 0462

392A8431
Appareils VQE1-1 VQE1-2 MLI A035 A035

28
Schma cblage N/A N/A

C
Safety Vanne d vacuation rapide Caractristiques : Normal : NC Vanne d vacuation rapide Caractristiques : Normal : NC Vanne de dcharge pompe principale huile de lubrification Caractristiques : Normal : NC Rglages : Ouverture 6,89 + 0,13/-0 bar Vanne de dcharge pompe principale huile HP Caractristiques : Normal : NC Rglages : 113,7 1,37 bar Vanne de dcharge pompe auxiliaire huile HP Caractristiques : Normal : NC Rglages : 113,7 1,37 bar Dsignation

TBFT-TMP-FR-GTE-0060 Rev : 001

0416

VR1

1016

N/A

0434

VR21

0947

N/A

0434

VR22

0947

N/A

0441

VR26

E026

N/A

Soupape de scurit pour la pression du vibreur de la trmie BP Caractristiques : Normal : NC Rglages : Ouverture 5 0,1 bar Soupape de dcharge pression alimentation combustible liquide Caractristiques : Normal : NC Rglages : Tarage : 6,2 0,2 bar Vanne de dcharge pompe fuel Caractristiques : Normal : NC Rglages : Tarage : 82,7 1,72 bar Soupape de scurit de la pompe PFA-31 Caractristiques : Normal : NC Rglages : Ouverture 12 1 bar Soupape de scurit de la pompe PFA-32 Caractristiques : Normal : NC Rglages : Ouverture 12 1 bar Vanne arrt fuel Caractristiques : Normal : NC Vanne d arrt injection d eau Caractristiques : Normal : NC Vanne d arrt injection d eau Caractristiques : Normal : NC Vanne d arrt et rglage gaz Caractristiques : Course maxi = 88,9 0,127 mm | Normal : NC Vanne thermostatique rgulant la temprature de l huile de graissage Caractristiques : Normal : E vers B ouvert, C ferm Rglages : Dbut d ouverture T d huile = 54 2C Vanne thermostatique rgulant la temprature d air d atomisation Caractristiques : Normal : B vers E ouvert, C ferm Rglages : T air = 102 5 C RTD temprature eau pattes turbine Caractristiques : Platine PT100 | 100 Ohm 0C | -50 260 C | 0,385 Ohm/C RTD temprature eau pattes turbine Caractristiques : Platine PT100 | 100 Ohm 0C | -50 260 C | 0,385 Ohm/C Thermocouple temprature drain faux dpart Caractristiques : Type K Thermocouple temprature drain faux dpart Caractristiques : Type K

0424

VR27

0992

N/A

0424

VR4

0992

N/A

0494

VR60-31

E021/E0 48 E021/E0 48 0511 A035 A035 0507

N/A

0494

VR60-32

N/A

0424 0462 0462 0422

VS1 VS2-1 VS2-2 VSR-1

N/A N/A N/A GAS

0420

VTR1-1

1035

N/A

0420

VTR2-1

1027

N/A

0420 0420 0442 0442

WT-TL-1 WT-TL-2 WWTD-1 WWTD-2

637T 637T 637T/09 20 637T/09 20

TURB TURB TURB TURB

SIZE

CAGE CODE

DWG NO

A4

392A8431

SECTION 01FR
SCALE
Ce document, proprit exclusive de GE Energy Products France SNC est strictement confidentiel Il ne peut tre communiqu, copi ou reproduit sans notre autorisation crite pralable.

SHEET
This document, exclusive property of GE Energy Products France SNC. is strictly confidential. It must not be communicated, copied or reproduced without our previous written consent.

28/28