e of Fuel Limit On RPM (25 RPM = Setting Available) or over and is removed at the time of Fuel Limit Off RPM (0 RPM = Setting Available) or below. A relevant LED in front side lights off when Engine completely runs.
2. Starting fuel limiter During starting period, the turbocharger is out of normal operation and therefore diesel engine is always in the incomplete combustion due to lack of air, which results in heavy smoke. Digital governors have fuel limiting function for starting, while hydraulic governor normally has not. However, the engine has adjustable fuel limiter for starting period regardless of the governor type. The fuel limiter piston for over load is also used for starting limiter to avoid excessive fuel injected into cylinder during starting period to avoid heavy smoke. During starting period, the engine automation system activate starting solenoid valve to supply compressed air to push the fuel limiter piston as shown in fig 5. The limiting position can be adjusted by guide when loosening locking screw. Be sure to lock the locking screw after adjustment.