RTXM191-404

1.25G SFP transceiver module with DDM function


RTXM191-404
Features
1310nm Fabry-Perot laser transmitter Up to 1.25Gbps data rate Duplex LC receptacle optical interface compliant Single +3.3V power supply DDM function implemented External calibration Hot-pluggable Receiver Loss of Signal Output AC coupling of PECL signals Serial ID module on MOD(0-2) International Class 1 laser safety certified Transmitter disable input Operating temperature range: -40oC ~ +85oC 15km on 9/125um SMF RoHS Compliant

Wuhan Telecommunication Devices Co., Ltd. http://www.wtd.com.cn

RTXM191-404 Application
1000BASE-LX Ethernet Gigabit Fiber Channel Switch to switch interface Switched backplane applications

Standard
Compliant Compliant Compliant Compliant with with with with SFP MSA (INF-8074i) SFF-8472 v9.3 IEEE802.3z Gigabit Ethernet FC-PI v2.0

Absolute Maximum Ratings


Parameter Storage Temperature Range Relative Humidity Power Supply Voltage Symbol Ts RH V cc Unit
o

Min -40 5 -0.5

Max +85 95 +4

% V

Recommended Operating Conditions


Parameter Case Operating Temperature Range Power Supply Voltage Data rate Symbol Tc V cc Unit
o

Min -40 3.135 -

Typ 3.3 1.25/1.0625

Max 85 3.465 -

C V

Gbps

Specifications
(tested under recommended operating conditions, unless otherwise noted) Parameter Tx Section Supply Current Rx Section Single Ended Data Input Swing Single Ended Data Output Swing TX_fault /LOS output (TTL) TX_disable input (TTL) Launch Optical Power Center Wavelength Range Extinction Ratio Symbol Icc VOH VOL VOH Unit mA mV mV V 150 300 2.0 0 Min Typ Max 300 1100 600 Vcc 0.8 Vcc 0.8 -3 1355 Notes

Electrical Characteristics 1

2.0 V VOL 0 Optical transmitter Characteristics Po dBm -9 -5 c EX nm dB 1270 9 1310

Wuhan Telecommunication Devices Co., Ltd. http://www.wtd.com.cn

RTXM191-404
Spectral Width(RMS) Contributed Total Jitter added at Relative Intensity Noise Eye Diagram Dispersion Penalty Optical Rise/Fall Time P out @TX-Disable Asserted Receiver Optical Wavelength Receiver Sensitivity Overload Input Optical Power LOS LOS Hysteresis De-Assert Assert T rise /T fall TJ RIN nm UI dB/H z dB ps 4 0.284 -120 1 260 -45 1620 -22 -3 -22 -35 0.5 3 5 6 -20 5 4 2 3

Complies with IEEE802.3z eye masks when filtered

P off dBm Optical receiver Characteristics IN S P in LOS D LOS A nm dBm dBm dB dB 1250

Note1: The supply current includes SFP modules supply current and test board working current. Note2: TP refers to the compliance point specified in IEEE802.3z, section 38.2.1. Note3: RIN is the laser noise, integrated over a specified bandwidth, measured relative to average optical power with 12dB return loss. For multimode application, the RIN is better than -117dB/Hz. Note4: Optical transition time is the time interval required for the rising or falling edge of an optical pulse to transition between the 20% and 80% amplitudes relative to the logical 1 and 0 levels Note5: Measured with a PRBS 223-1 test pattern, @1.25Gb/s, EX=10dB, BER<10-12. Note6: The LOS Hysteresis to minimize chatter on the output line. In principle, Hysteresis alone does not guarantee chatter-free operation.

Wuhan Telecommunication Devices Co., Ltd. http://www.wtd.com.cn

RTXM191-404 Digital Diagnostic Memory Map

EEPROM Serial ID Memory Contents


Accessing Serial ID Memory uses the 2 wire address 1010000X (A0). Memory Contents of Serial ID are shown in Table 2. Table 2 Serial ID Memory Contents Data Address Size (Bytes) Name of Field Contents(Hex) BASE ID FIELDS Description

0 1 2 3-10 11 12 13 14

1
1 1 8 1 1 1 1

Identifier Ext. Identifier Connector Transceiver Encoding BR, Nominal Reserved Length (9m) km

03 04 07 xx xx xx xx xx xx xx xx 03 0D 00 0F

SFP SFP function is defined by serial ID LC Transceiver Codes NRZ 1.25Gbit/s Transceiver transmit distance 4

Wuhan Telecommunication Devices Co., Ltd. http://www.wtd.com.cn

RTXM191-404
15 16 17 18 19 20-35 36 37-39 40-55 56-59
60-61 1 1 1 1 1 16 Length (9m) 100m Length (50m) 10m Length(62.5m)10m Length (Copper) Reserved Vendor name Reserved Vendor OUI Vendor PN Vendor rev Wavelength Reserved CC_BASE 96 00 00 00 00 57 54 44 20 20 20 20 20 20 20 20 20 20 20 20 20 00 00 1C AD 52 54 58 4D 31 39 31 2D 34 30 34 20 20 20 20 20 xx xx xx 20 05 1E 00 xx EXTENDED ID FIELDS Check sum for Base ID Fields TX_DISABLE, TX_FAULT and Loss of Signal implemented. WTD IEEE ID RTXM191-404 (ASCII) ASC(33 2E 30 20means V3.0) 1310nm WTD(ASCII) 15km

1
3 16 4 2 1 1

62
63

64-65
66 67 68-83 84-91

2
1 1 16 8

Options BR,max BR,min Vendor SN Date code Diagnostic Monitoring Type

00 1A 00 00 xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx 20 20

Serial Number of transceiver (ASCII). Year(2)Month(2)Day(2) (ASCII). Digital diagnostic monitoring, externally calibrated is implemented, RX measurement type is Average Power. Optional Alarm/Warning flags implemented for all monitored quantities, Optional Soft TX_FAULT monitoring implemented, Optional Soft RX_LOS monitoring implemented. Includes functionality described in Rev9.3 SFF-8472. Check sum for Extended ID Field. Depends on customer information Filled by zero

92

58

93

Enhanced Options

B0

94 95

1 1

SFF_8472 Compliance 01 CC_EXT Vendor Specific Reserved xx VENDOR SPECIFIC ID FIELDS Read only Read only

96-127

32

128-255 128

Wuhan Telecommunication Devices Co., Ltd. http://www.wtd.com.cn

RTXM191-404 Diagnostic Monitor Functions


Diagnostic Monitor Functions interface uses the 2 wire address 1010001X (A2). Memory contents of Diagnostic Monitor Functions are shown in Table 3 Table 3 Memory contents of Diagnostic Monitor Function Data Address 00-01 02-03 04-05 06-07 08-09 10-11 12-13 14-15 16-17 18-19 20-21 22-23 24-25 26-27 28-29 30-31 32-33 34-35 36-37 38-39 40-55 Field Size (bytes) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 16 Name Contents and Description

Alarm and Warning Thresholds Temperature High Alarm Set to 100 oC Temperature Low Alarm Set to -45 oC Temperature High Warning Temperature Low Warning Vcc High Alarm Vcc Low Alarm Vcc High Warning Vcc Low Warning Bias High Alarm Bias Low Alarm Bias High Warning Bias Low Warning TX Power High Alarm TX Power Low Alarm TX Power Low Warning RX Power High Alarm RX Power Low Alarm RX Power Low Warning Reserved Calibration Constants 56-59 60-63 64-67 68-71 72-75 4 4 4 4 4 RX Power Calibration Data4 RX Power Calibration Data3 RX Power Calibration Data2 RX Power Calibration Data1 RX Power Calibration 6 Single precision floating-point numbers (various values at each device) Single precision floating-point numbers (various values at each device) Set to 90 oC Set to -40 oC Set to 3.6 V Set to 3.0 V Set to 3.5 V Set to 3.1 V 2 x IBias (25 oC ) +40 20% x IBias (25 oC ) 2 x IBias (25 oC ) +30 25% x IBias (25 oC ) Manufacture measurement plus 2dB Manufacture measurement minus 2dB Manufacture measurement minus 1dB Overload input optical power Maximum receiver sensitivity Maximum receiver sensitivity plus 3dB

TX Power High Warning Manufacture measurement plus 1dB

RX Power High Warning Overload input optical power minus 3dB

Wuhan Telecommunication Devices Co., Ltd. http://www.wtd.com.cn

RTXM191-404
Data0 76-77 78-79 80-81 82-83 84-85 86-87 88-89 90-91 92-94 95 96-97 98-99 100-101 102-103 104-105 106-109 110 111 112-119 120-122 123-126 127 128-247 248-255 2 2 2 2 2 2 2 2 3 1 2 2 2 2 2 4 1 1 8 3 4 1 120 8 Bias Calibration Data1 Bias Calibration Data0 TX Power Calibration Data1 TX Power Calibration Data0 Temperature Calibration Data1 Temperature Calibration Data0 Vcc Calibration Data1 Vcc Calibration Data0 Reserved Check Sum Measured Temperature Measured Vcc Measured Bias Measured TX Power Measured RX Power Reserved Logic Status See Table 3.2 AD Conversion Updates See Table 3.2 Alarm and Warning Flags See Table 3.3 Vendor Specific Vendor Specific Password Entry Table Select Byte User writable EEPROM Vendor Specific Dont Access Write only Write/read Write/read Dont Access 00 01 (fixed) 00 00 (fixed) 00 01 (fixed) 00 00 (fixed) 00 01 (fixed) 00 00 (fixed) 00 01 (fixed) 00 00 (fixed) 00 00 00 (fixed) Checksum of bytes 0-94 Yield a 16-bit A/D value (see Table 3.1) Yield a 16-bit A/D value (see Table 3.1) Yield a 16-bit A/D value (see Table 3.1) Yield a 16-bit A/D value (see Table 3.1) Yield a 16-bit A/D value (see Table 3.1)

Real Time Diagnostic Monitor Interface

The measured values located at bytes 96-105(in the 2 wire address 0xA2) are raw A/D values (16-bit integers) of transceiver temperature, supply voltage, laser bias current, laser optical output power and received power. All the measured values are Externally Calibrated, and then it is necessary to convert raw A/D values to real world units by the manner as shown in Table 3.1. Table 3.1 Real Time Diagnostic Monitor Values Byte Name 96 97 98 99 Temperature MSB Temperature LSB Vcc MSB Vcc LSB Description Internally measured transceiver temperature. Compliant with External Calibration of SFF-8472. Internally measured supply voltage. Compliant with External Calibration of SFF-8472. 7

Wuhan Telecommunication Devices Co., Ltd. http://www.wtd.com.cn

RTXM191-404
100 Laser Bias MSB 101 Laser Bias LSB 102 Tx Power MSB 103 Tx Power LSB 104 Rx Power MSB 105 Rx Power LSB Measured Laser bias current. Compliant with External Calibration of SFF-8472. Measured Tx power. Compliant with External Calibration of SFF-8472. Measured Tx power. Compliant with External Calibration of SFF-8472.

This transceiver implements two optional status bytes, Logic States at byte 110(0xA2) and A/D Updated at byte 111(0xA2) as shown in Table 3.2. A/D Updated status bits allow the user to verify if an update from the analog-digital conversion has occurred of the measured values, temperature, Vcc, laser bias, Tx power and Rx power. The user writes the byte to 0x00. Once a conversion is completed for a given value, its bit will change to 1 Table 3.2 Logic Status and AD Conversion Updates Byte 110 110 110 110 110 110 110 110 111 111 111 111 111 111 111 111 Bit Name 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Tx Disable State Soft Tx Disable Control Reserved Rx Rate Select State Soft Rate Select Control Tx Fault LOS Power on Logic Temp A/D Valid Vcc A/D Valid Laser Bias A/D Valid Tx Power A/D Valid Rx Power A/D Valid Reserved Reserved Reserved Description Optional digital State of the Tx Disable input pin. Not supported (set to 0). Set to 0. Not supported (set to 1). Not supported (set to 0). Optional digital state of the Tx Fault output pin. Optional digital state of the LOS output pin. Bit will be 0 when the analog monitoring is active. Indicates A/D value in Bytes 96/97 is valid. Indicates A/D value in Bytes 98/99 is valid. Indicates A/D value in Bytes 100/101 is valid. Indicates A/D value in Bytes 102/103 is valid. Indicates A/D value in Bytes 104/105 is valid. Set to 0. Set to 0. Set to 0.

Each of the measured values has a corresponding high alarm, low alarm, high warning and low warning threshold level at location 00-39(x0A2) written as the data format of a corresponding valued shown in Table 3.3.Alarm and warning flags at bytes 112-119(0xA2) are defined as follows. (1) Alarm flags indicate conditions likely to result (or have resulted) in link failure and cause for immediate action. (2) Warning flags indicate conditions outside the guaranteed operating specification of transceiver but not necessarily causes of immediate link failures. Table 3.3 Alarm and Warning Flags Byte Bit(s) Name 112 112 112 112 7 6 5 4 Temperature High Alarm Temperature Low Alarm Vcc High Alarm Vcc Low Alarm Description Set when temperature monitor value exceeds high alarm level. Set when temperature monitor value exceeds low alarm level. Set when Vcc monitor value exceeds high alarm level. Set when Vcc monitor value exceeds Low alarm level. 8

Wuhan Telecommunication Devices Co., Ltd. http://www.wtd.com.cn

RTXM191-404
112 112 112 112 113 113 113 114 115 116 116 116 116 116 116 116 116 117 117 117 118 119 3 2 1 0 7 6 5-0 7-0 7-0 7 6 5 4 3 2 1 0 7 6 5-0 7-0 7-0 Laser Bias High Alarm Laser Bias Low Alarm Tx Power High Alarm Tx Power Low Alarm Rx Power High Alarm Rx Power Low Alarm Reserved Reserved Reserved Set when laser bias monitor value exceeds high alarm level. Set when laser bias monitor value exceeds low alarm level. Set when Tx power monitor value exceeds high alarm level Set when Tx power monitor value exceeds low alarm level. Set when Rx power monitor value exceeds high alarm level Set when Rx power monitor value exceeds low alarm level All bits set to 0. All bits set to 0. All bits set to 0.

Temperature High warning Set when temperature monitor value exceeds high warning level. Temperature Low warning Set when temperature monitor value exceeds low warning level. Vcc High warning Vcc Low warning Laser Bias High warning Laser Bias Low warning Tx Power High warning Tx Power Low warning Rx Power High warning Rx Power Low warning Reserved Reserved Reserved Set when Vcc monitor value exceeds high warning level. Set when Vcc monitor value exceeds Low warning level. Set when laser bias monitor value exceeds high warning level. Set when laser bias monitor value exceeds low warning level. Set when Tx power monitor value exceeds high warning level Set when Tx power monitor value exceeds low warning level. Set when Rx power monitor value exceeds high warning level Set when Rx power monitor value exceeds low warning level All bits set to 0. All bits set to 0. All bits set to 0.

Pin Description
20 19 18 17 16 15 14 13 12 11 VeeT TDTD+ VeeT VccT VccR VeeR RD+ RDVeeR 1 2 3 4 5 6 7 8 9 10 VeeT Tx_Fault Tx_disable MOD-DEF(2) MOD-DEF(1) MOD-DEF(0) Rate Select LOS VeeR VeeR

Top of Board

Bottom of Board

As Viewed Through Top of Board

Wuhan Telecommunication Devices Co., Ltd. http://www.wtd.com.cn

RTXM191-404
Pin 1 2 3 4 5 6 7 8 9 Name VeeT TX Fault TX Disable MOD-DEF2 MOD-DEF1 MOD-DEF0 LOS VeeR Function/Description Transmitter Ground Transmitter Fault Indication Transmitter Disable-Module disables on high or open Module Definition 2-Two wire serial ID interface Module Definition 1-Two wire serial ID interface Module Definition 0-Two wire serial ID interface Loss of Signal Receiver Ground Receiver Ground Receiver Ground Inverse Received Data out Received Data out Receiver Ground Receiver Power ---- +3.3V5% Transmitter Power ---- +3.3 V5% Transmitter Ground Transmitter Data In Inverse Transmitter Data In Transmitter Ground Engagement order 1 3 3 3 3 3 3 3 1 1 1 3 3 1 2 2 1 3 3 1 7 7 6 6 5 5 4 1 2 3 3 3 Notes

Rate Select Not Connected

10 VeeR 11 Veer 12 RD13 RD+ 14 VeeR 15 VccR 16 VccT 17 VeeT 18 TD+ 19 TD20 VeeT

Note1: TX Fault is open collector/drain output which should be pulled up externally with a 4.7K 10K resistor on the host board to supply <VccT+0.3V or VccR+0.3V. When high, this output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to <0.8V. Note2: TX Disable input is used to shut down the laser output per the state table below. It is pulled up within the module with a 4.7 10K resistor. Low (0 0.8V): High (2.0 VccT): Open : Transmitter on Between (0.8V and 2V): Undefined Transmitter Disabled Transmitter Disabled

Note3: Mod-Def 0, 1, 2. These are the module definition pins. They should be pulled up with a 4.7 - 10K resistor on the host board to supply less than VccT+0.3V or VccR+0.3V. Mod-Def 0 is grounded by the module to indicate that the module is present. Mod-Def 1 is clock line of two wire serial interface for optional serial ID. Mod-Def 2 is data line of two wire serial interface for optional serial ID. Note4: LOS (Loss of signal) is an open collector/drain output which should be pulled up externally with a 4.7 10K resistor on the host board to supply <VccT+0.3V or VccR+0.3V. When high, this output indicates the received optical power is below the worst case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to <0.8V. Note5: RD-/+: These are the differential receiver outputs. They are AC coupled 100 differential lines which should be terminated with 100 differential at the user SERDES. The AC coupling is done inside the module and thus not required on the host board. Note6: VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V5% at the SFP connector pin. The in-rush current will typically be no more than 30mA above steady state supply current after 500ns. Note7: TD-/+: These are the differential transmitter inputs. They are AC coupled differential lines with 100 Wuhan Telecommunication Devices Co., Ltd. http://www.wtd.com.cn 10

RTXM191-404
differential termination inside the module. The AC coupling is done inside the module and is thus not
required on host board.

Block diagram

Required Host Board Components


The MSA power supply noise rejection filter is required on the host PCB to meet data sheet performance. The MSA filter incorporates an inductor which should be rated 400mA DC and 1serial resistance or better. It should not be replaced with a ferrite. The required filter is illustrated in Figure 3. The MSA also specifies that 4.7K to 10K pull-up resistors for TX_FAULT, LOS, and MOD_DEF0,1,2 are required on the host PCB. Figure is the suggested transceiver/host interface.

Wuhan Telecommunication Devices Co., Ltd. http://www.wtd.com.cn

11

RTXM191-404 Typical application circuit

Laser Driver

Receiver Amplifier

Package outline

(unit: mm)

Wuhan Telecommunication Devices Co., Ltd. http://www.wtd.com.cn

max

12

RTXM191-404 PCB layout recommendation

Regulatory Compliance
Feature Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge (ESD) Immunity Test Method MIL-STD-883E Method 3015.7 IEC61000-4-2 Performance Class 1 (>1.5kV) Human Body Model

Class 2(>4.0kV) 13

Wuhan Telecommunication Devices Co., Ltd. http://www.wtd.com.cn

RTXM191-404
CISPR22 ITE Class B Electromagnetic Interference FCC Class B (EMI) CENELEC EN55022 VCCI Class 1 Typically show no measurable effect from a 3 V/m field Immunity IEC61000-4-3 Class 2 swept from 80 to 1000MHz applied to the transceiver without a chassis enclosure. FDA 0322110-08 CDRH 21-CFR 1040 Class 1 Safety UL E239070 TUV R50111637 0001 CE E8 0501 54481 004 Compliant with standard

Ordering Information
Part No. RTXM191-404 Specification Package Data rate SFP 1.25G Laser Power Detector Sensitivity PIN Top
o

Application Reach Other Code

1310nm FP -9 ~ -3dBm

< -20dBm -40~85 C 15km DDM, RoHS 1000Base-LX

WTD reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Edition 2009-12-01 Published by Wuhan Telecommunication Devices Co.,Ltd. Copyright WTD All Rights Reserved.

Wuhan Telecommunication Devices Co., Ltd. http://www.wtd.com.cn

14