You are on page 1of 2

FFFF

FA01
FA100

O
O

Emergency stop

Level
Level /

Servo power off

This
This error occurred as follows /

1. When the emergency stop signal is activated

How
How to recover /

1. Reset the emergency stop signal.

2. Please check whether the connector of the teaching box is not disconnected.
T-Box
3. Connect the CN105 of FA01 connector.
FA01CN105

FA01 controller / FA01


A in fig. HMI , PLC connector. (CN105)
B in fig. Jumper. (JP1)
C in fig. T-Box connector. (CN106)
A. PLC(CN105)
B. (JP1)
C. T-Box(CN106)
4. When you have to take T-Box out, short circuit the JP1 jumper. When taken out please
check the 24V.
T-BoxJP124V

When jumper JP1 is not short. / FA01-JP1()

FA01 controller / FA01


A in fig. 24 V connection. (TB101.16PIN (24G), 17PIN (+24V), 18PIN (24G))
A. 24V(TB101 16(24G)17(+24V)18(24G))

When emergency stop is not pressed on T-Box


T-Box
1. When emergency stop button is pressed but still no error is given out ,then disconnect JP1
in such a manner that it is not short circuited. Right now JP1 has disconnected the T-Box
but when operating practically don't do that.
T-BoxJP1(FA01JP1)
Error
Error detailed information (detail2) /
(
(2
2)
1. Number of task