P2

BOOSTER PUMP NO.2 P3

BOOSTER PUMP NO.3

2L3

2L2

2L1

4FU (NOTE 1)

3L1

3L2

3L3
5FU

(NOTE 1)

P2-T1

P2-T2

2L1-1

2L2-1

2L3-1

P2-T3

3L1-1

3L2-1

3L3-1

P3-T1

P3-T2
U V

L1 VFD2 VFD2

L2

L3

PE

PE

L1

L2

L3

PE

PE

P3-T3
W NETWORK TERMINATOR

RED RED P+ N2 1 5 GRN GRN GRN

RED

+10V 0V

-24-1 O1.2 5 O1.3

-24-1

AUDIBLE ALARM

RED

BLK

RED

+24-1

-24-1

-24-1 33 34 +24-1 35 36 37 38

N H2

O1.7

A+ A-

USER SUPPLIED (24VDC to 230VAC) DRIVE/PUMP FAIL HIGH SYSTEM PRESSURE LOW SYSTEM PRESSURE LOW SUCTION PRESSURE OR LEVEL

USER SUPPLIED (24VDC to 230VAC) HIGH SUCTION PRESSURE PUMP 1 RUNNING PUMP 2 RUNNING PUMP 3 RUNNING

RUN STOP
Q0

SF

1L 0.0 0.1 0.2 0.3


.0 .1 .2 .3 .4 .5 .6 .7 .0 .1 .2 .3 .4 .5 .6 .7
Q1

2L 0.4 0.5 0.6 0.7 1.0


N L1 AC

3L 1.1 1.2 1.3 1.4 1.5 1.6 1.7

RA A+ A- RB B+ B- RC C+ C- RD D+ D-

ANALOG INPUT MODULE


.0 .1 .2 .3 .4 .5 .6 .7
I1 I2
21 6-2BD21-0XB 0

B+ B-

BLK

1M

I0.5 I0.6

I1.4

Page 1 of 2
SUCTION PRESSURE PT-1
1 2 1 2

PT-2

DISCHARGE PRESSURE

MODEM MODULE

I0

.0 .1 .2 .3 .4 .5 .6 .7

.0 .1 .2 .3 .4 .5 .6 .7

1M 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 1.0 1.1 1.2 1.3 1.4

2M 1.5 1.6 1.7 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 M L+

231-0HC22-0XA0

241-1A A 22-0X A0

M L+

M L+ DC

PORT 1

PORT 0

81 USER SUPPLIED DRY CONTACT REMOTE START/STOP J2 (NOTE 2) J3 (NOTE 3) 80 +24-3

+24-3 -24-3

+24-3 -24-3

FILE NO.: DATE: SUPERSEDES: DATE:

+24-3

62.661 Mar. 23, 2010 62.661 Oct. 20, 2009

WIRING DIAGRAM SUBMITTAL

Triplex VFD Booster Schematic

-24-3

LINE REACTOR (SHIPPED SEPERATELY) DS-1 L1 L2 L3 (NOTE 1) P1 BOOSTER PUMP NO.1 (NOTE 1)

4L1

4L3

1FU

208/230/460/575 VOLTS 3 PHASE 60 HERTZ (NOTE 1) H1 N

2FU

1L1-1

1L3-1

P1-T1

P1-T2
U V

CB-1

2A

(NOTE 1) 1 H2 THERMOSTAT TS-1 103 RED GRN GRN -24-1 O1.1 5 RED 3 COOLING FAN(S) (NOTE 1) N -24-1 T1 N VFD1 AQUASTAT 102 2 SOLENOID VALVE (NOTE 5) L1 L2 L3 PE PE W T2

Armstrong Pumps Inc. 93 East Avenue North Tonawanda, New York U.S.A. 14120-6594 T: (716) 693-8813 F: (716) 693-8970
H2 PLC POWER INPUT L V+ +24-1 PT-1 PT-2 I/O -24-1 2 OPERATOR INTERFACE IF1B RS-485 -24-2 24VDC POWER SUPPLY VN +24-2 1 PPI NOTES: USS PROT. 1. ITEMS PER VOLTAGE, UL, DRIVE MANUFACTURER REQUIREMENTS. 2. JUMPER J2 REQUIRED TO ACTIVATE STANDBY PUMP OPERATION. 3. JUMPER J3 REQUIRED TO ACTIVATE LOW SUCTION LEVEL SHUTDOWN. 4. LINE REACTOR SHIPPED SEPARATELY, TO BE INSTALLED BYOTHER. 5. AQUASTAT AND SOLENOID VALVE FOR CONTINUOUS RUN SYSTEMS ONLY.

For Armstrong locations worldwide, please visit www.armstrongintegrated.com


1L1 1L2 1L3
3FU (NOTE 1)

1L2-1

P1-T3

S. A. Armstrong Limited 23 Bertrand Avenue Toronto, Ontario Canada, M1L 2P3 T: (416) 755-2291 F (Main): (416) 759-9101

Page 2 of 2

Armstrong Holden Brooke Pullen Wenlock Way Manchester United Kingdom, M12 5JL T: +44 (0) 161 223 2223 F: +44 (0) 161 220 9660

S.A. Armstrong Limited 2010