You are on page 1of 9

1

10

11

12

13

14
BLD-1 Sub Contractor

15
ABN 98 000 893 667

16
LEIGHTON CONTRACTORS PTY LTD

STEELWORK NOTES:
A
1. REFER DRG Z24051 FOR GENERAL AND STEELWORK NOTES 2. ALL EXTERNAL AND EXPOSED STEELWORK TO BE HOT-DIP GALVANISED INCLUDING EXPOSED RAFTERS, BRACING AND COLUMNS IN EXTERNAL UNDERCROFT AREAS. 3. PROVIDE FLY BRACING TO ALL RAFTERS AND UB SECTION COLUMNS AT 3.0m CENTRES TYPICALLY U.N.O. 4. BASE FIXINGS - ALLOW FOR 4min x CAST-IN HOLD DOWN BOLTS TO EACH COLUMN (xC). ALLOW FOR 2min x CHEMSET ANCHORS TO EACH MULLION (xM). 5. ALL RAFTERS TO BE SPLICED AT 18m MAXIMUM LENGTH OR AT LOCATIONS AS INDICATED ON THE DRAWINGS. SPLICE TO BE FULL MOMENT BOLTED SPLICE CONNECTIONS. 6. ALL RAFTER/ UB COLUMN CONNECTIONS TO BE BOLTED END PLATE MOMENT CONNECTIONS. 7. DESIGN IS BASED ON THE FOLLOWING SHEETING PROFILES: - ROOF SHEETING - TRIMDEK 0.48BMT - CREST FASTENED WITH CYCLONIC WASHERS IN ACCORDANCE WITH MANUFACTURERS SPECIFICATION. - WALL CLADDING SPANDEK 0.48BMT VALLEY FASTENED. 8. WALL STUD FRAMING IS SHOWN INDICATIVELY ONLY AND IS TO BE DESIGNED AND CERTIFIED BY OTHERS. 9. STUDS TO BE DESIGNED TO THE WINDLOAD CRITERIA AS SPECIFIED IN THE GENERAL NOTES ON DWG Z24051. WINDLOADING TO BE CALCULATED IN ACCORDANCE WITH AS1170.2. 10. WALL STUDS - MAXIMUM DEFLECTION CRITERIA UNDER V25 WIND SPEED HEIGHT/240 11. MINIMUM STUD BASE METAL THICKNESS 1.5mm.

WAREHOUSE STEEL FRAMING SCHEDULE MARK DESCRIPTION


BEAMS aB1 aB2 BRACING aBR1 aBR2 aVB1 aVB2 COLUMNS aC1 aC2 aC3 aC4 aC5 aC6 HEADS aH1 aH2 aH3 aH4 aH5 MULLIONS aM1 aM2 aM3 aM4 RAFTERS aR1 aR2 aR3 aR4 STRUTS aS1 aS2 aS3 aS4 460UB82 310UB46 125x8.0 EA 20mm DIA. CROSS ROD BRACING 125x8.0 EA VERT. CROSS BRACING 20mm DIA. VERT. CROSS ROD BRACING 610UB101 460UB67 410UB54 200x6.0 SHS 150x5.0 SHS 310UB40 250x150x5.0 RHS (ON FLAT) 150x100x5.0 RHS (ON FLAT) 200x6.0 SHS 150x5.0 SHS 200x100x5.0 RHS (ON FLAT) 200PFC 150x100x4.0 RHS 150x50x4.0 RHS 250PFC 610UB101 460UB67 310UB32 300PFC 150x5.0 SHS 125x5.0 SHS 89x3.5 SHS 200x5.0 SHS
Architect

Level 6 HQ South Tower 520 Wickham Street Fortitude Valley QLD 4006 Australia PO Box 1077 Fortitude Valley QLD 4006 T +61 7 3215 4600 F +61 7 3215 4666 www.leightoncontractors.com.au

BVN Donovan Hill PO Box 801 Fortitude Valley QLD 4006 T +61 7 3852 2525 F +61 7 3852 2544 www.bvn.com.au
Structural/Civil/Mechanical/Electrical/Hydraulic Engineers

OPUS PO Box 99 Spring Hill QLD 4004 T +61 7 3838 2400 F +61 7 3838 2401 www.opus.com.au

ICHTHYS ONSHORE LNG FACILITIES

Darwin Australia

Subcontractor ISSUE PURPOSE: CTR RESULT CODE: NEXT STATUS:

FA A FA

FR B FR

FI N FI

FC F FC

AB CA AB NA

Subcontractor RESUB / NEXTSUB DATE:


Approval or review hereunder shall not be construed to relieve Vendor / Subcontractor of his responsibilities and liability under the Contract.

CTR ORGANIZATION PJ DEPT RESPONSIBLE DEPT RELATED DEPT

DEPT NAME

SIGNATURE

CTR REVIEW DATE: JOB NO CPY DOC NO 0-6037-2 REVIEW CLASS

2
REV

SYSTEM NO - CLASS/DISC - TYPE - SERIAL NO

BN

CA

CB

CC

CD

CE

CF

CG

L290-DS-PAE-10112.001
PURCHASER ORDER NO - SERIAL NO

CTR DOC NO

V-31D1-BLD-1-A24120

WAREHOUSE PURLIN & GIRTS SCHEDULE


aG1 aG2 aG3 aP1 aP2 aP3 aP4 aP5 aP6 aP7 aT1 aT2 Z20019 AT 750 MAX CTRS + 1 ROW BRIDGING Z20024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20019 AT 1500 MAX CTRS + 1 ROW BRIDGING Z25019 AT 750 MAX CTRS + 1 ROW BRIDGING Z25024 AT 1500 MAX CTRS + 1 ROW BRIDGING Z25019 AT 1500 MAX CTRS + 1 ROW BRIDGING Z25024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20019 AT 750 MAX CTRS + 1 ROW BRIDGING C20015 TRIMMER PURLIN C25019 TRIMMER PURLIN

2 aC

2 aC

aS1(u)

2 aC

2 aC

2 aC

aS1(u)

2 aC

2 aC

35

2-aVB2(u)

2-aVB2(u)

CH
F
1 aC 4 aC 4 aC 4 aC 4 aC 4 aC 1 aC 5 aC

aT1

aR3

33

aP7
R aB 2 aB R2

1 aC

4 aC

1 aC

aS3 aR3
5 aC

BM
1

31
A24130

FOR CONTINUATION REFER DWG. F24124

aS3

AA A NO

11-APRIL-13 TENDER ISSUE 13-MAR-13 30% ISSUE DATE

ISSUE PURPOSE

SWS SWS CKD

DDG DDG APP

1 aC
EK ND O 1B

NG MI A R B F C4 A a SL

REVISIONS
1 aC 5 aC

aR3

29
aP7 3000

aS3

F RE

ER

A G. W D

1 aC

aS4

0 10 24

R FO

L AL

L VE E L

aP2

ICHTHYS ONSHORE LNG FACILITIES


DRAWING TITLE

WAREHOUSE - ROOF STEELWORK FRAMING PLAN - EPC BUILDING WORKS SHEET 1


5 aC

4 aC

1 aC

aR3

27
SCALE COMPANY CONTRACT NO

1 : 100 2
LEICON REV

REVIEW CLASS

aS3

JGC JOB CODE

KBR JOB CODE

CHD JOB CODE

LEIGHTON DWG NO

Q1447-V-31D1-BLD-1-A24120
1 aC 4 aC 1 aC

AA
SIZE

aR3

5 aC

JKC DWG NO

25
14

V-31D1-BLD-1-A24120
COMPANY DWG NO

A1
COY REV

FOR CONTINUATION REFER DWG. A24121


1 2 3 4 5 6 7 8 9 10 11 12 13

L290-DS-PAE-10112.001 15 16

10

11

12

13

14
BLD-1 Sub Contractor

15
ABN 98 000 893 667

16
LEIGHTON CONTRACTORS PTY LTD

04
A

05
bR 3

06
bR 3

07
bR 3

01

11
B24131

02

03
bR 3

INTERNAL VERTICAL

TOP CHORD

08
CL. TOP CHORD 2600
bR 3

09
bS3
bR 3

10
bS3
bR 3

11
Architect

Level 6 HQ South Tower 520 Wickham Street Fortitude Valley QLD 4006 Australia PO Box 1077 Fortitude Valley QLD 4006 T +61 7 3215 4600 F +61 7 3215 4666 www.leightoncontractors.com.au

bS3
bH 5

BVN Donovan Hill PO Box 801 Fortitude Valley QLD 4006 T +61 7 3852 2525 F +61 7 3852 2544 www.bvn.com.au
Structural/Civil/Mechanical/Electrical/Hydraulic Engineers

bR 3

bR 3

bS3 bM1(b)

bS3

bR 3

bR 4

bS1

bS1

CL. BTM. CHORD

bR 3

BTM. CHORD END VERTICAL DIAGONALS END VERTICAL bC8

bC8

bC1

bC1

bC4

bC1

B4 bV

bC1

B4 bV

bH 1

bC1

bC10

TR1 TRUSS

OPUS PO Box 99 Spring Hill QLD 4004 T +61 7 3838 2400 F +61 7 3838 2401 www.opus.com.au

bR 4

B4 bV

bV B

ICHTHYS ONSHORE LNG FACILITIES

bH 1

Darwin Australia

LEVEL 00

LEVEL 00

Subcontractor ISSUE PURPOSE: CTR RESULT CODE: NEXT STATUS:

FA A FA

FR B FR

FI N FI

FC F FC

AB CA AB NA

Subcontractor RESUB / NEXTSUB DATE:

SECTION TR1 - TRUSS SCHEDULE


TOP CHORD: INTERNAL VERTICALS: END VERTICALS: DIAGONALS: BOTTOM CHORD: 200UC46 (ON FLAT) 200UB25 200UC46 200UB25 200UC46 (ON FLAT)

1
B24120

Approval or review hereunder shall not be construed to relieve Vendor / Subcontractor of his responsibilities and liability under the Contract.

TR2 - TRUSS SCHEDULE


TOP CHORD: INTERNAL VERTICALS: END VERTICALS: DIAGONALS: BOTTOM CHORD: 200UC52 (ON FLAT) 200UB18 200UC46 200UB18 200UC52 (ON FLAT) C.L. OF TOP CHORD

1 : 100

SECTION
1 : 100

5
B24120

CTR ORGANIZATION PJ DEPT RESPONSIBLE DEPT RELATED DEPT

DEPT NAME

SIGNATURE

CTR REVIEW DATE:

04
INTERNAL VERTICAL
bR 3

05
bR 3

06
bR 3

07 08 09
bS 3

JOB NO CPY DOC NO

0-6037-2

REVIEW CLASS

2
REV

SYSTEM NO - CLASS/DISC - TYPE - SERIAL NO

D
2600

C.L. OF TOP CHORD 1500

10
hOR1

11
bS 3

L290-DS-CSD-10005.001
PURCHASER ORDER NO - SERIAL NO

TOP CHORD

CL. TOP CHORD 1500


bS1
bR3

CTR DOC NO

bR 3

V-31D1-BLD-1-B24130

bR 4

C.L. OF BTM. CHORD / C.L. OF ROOF BRACING

bR 4

C.L. OF BTM. CHORD

CL. BTM. CHORD

hOR1

bH 3 bS 3

bC8

E
bM3 bC6 bM3 bC6

LEVEL 00

bC8

DIAGONALS

TR2 TRUSS

LEVEL 00 VEHICLES

STEELWORK NOTES:
F
1. REFER DRG Z24051 FOR GENERAL AND STEELWORK NOTES 2. ALL EXTERNAL AND EXPOSED STEELWORK TO BE HOT-DIP GALVANISED INCLUDING EXPOSED RAFTERS, BRACING AND COLUMNS IN EXTERNAL UNDERCROFT AREAS. 3. PROVIDE FLY BRACING TO ALL RAFTERS AND UB SECTION COLUMNS AT 3.0m CENTRES TYPICALLY U.N.O. 4. BASE FIXINGS - ALLOW FOR 4min x CAST-IN HOLD DOWN BOLTS TO EACH COLUMN (xC). ALLOW FOR 2min x CHEMSET ANCHORS TO EACH MULLION (xM). 5. ALL RAFTERS TO BE SPLICED AT 18m MAXIMUM LENGTH OR AT LOCATIONS AS INDICATED ON THE DRAWINGS. SPLICE TO BE FULL MOMENT BOLTED SPLICE CONNECTIONS. 6. ALL RAFTER/ UB COLUMN CONNECTIONS TO BE BOLTED END PLATE MOMENT CONNECTIONS. 7. DESIGN IS BASED ON THE FOLLOWING SHEETING PROFILES: - ROOF SHEETING - TRIMDEK 0.48BMT - CREST FASTENED WITH CYCLONIC WASHERS IN ACCORDANCE WITH MANUFACTURERS SPECIFICATION. - WALL CLADDING SPANDEK 0.48BMT VALLEY FASTENED. 8. WALL STUD FRAMING IS SHOWN INDICATIVELY ONLY AND IS TO BE DESIGNED AND CERTIFIED BY OTHERS. 9. STUDS TO BE DESIGNED TO THE WINDLOAD CRITERIA AS SPECIFIED IN THE GENERAL NOTES ON DWG Z24051. WINDLOADING TO BE CALCULATED IN ACCORDANCE WITH AS1170.2. 10. WALL STUDS - MAXIMUM DEFLECTION CRITERIA UNDER V25 WIND SPEED HEIGHT/240 11. MINIMUM STUD BASE METAL THICKNESS 1.5mm.

SECTION
1 : 100

2
B24120

SECTION
1 : 100

6
B24121

04
bR 2

05
bR 3

06
bR 3

07
bR 4

08
bS3 1500 CL. TOP CHORD
3
hOR1

09
bS 3

10
hOR1

bH 3

END VERTICAL

BTM. CHORD

END VERTICAL

bS

11
bS 3

INTERNAL VERTICAL

bS1

TOP CHORD

END VERTICAL bC8

BTM. CHORD

END VERTICAL bC8

TR2 TRUSS

bH 3 bS 3

bM3

H
STEEL FRAMING SCHEDULE. MARK DESCRIPTION
BRACING bBR1 bBR4 bVB1 bVB2 bVB4 bVB5 COLUMNS bC1 bC2 bC4 bC6 bC7 bC8 bC9 bC10 bM1 bM2 bM3 HEADS bH4 bH5 OUTRIGGERS hOR1 RAFTERS bR2 bR3 bR4 bR5 STRUTS bS1 bS3 30mm DIA. CROSS ROD BRACING 75x8.0 EA CROSS BRACING 30mm DIA. VERT. CROSS ROD BRACING 75x8.0 EA 150x5.0 SHS 100x8.0 EA VERT. CROSS BRACING 150x5.0 SHS 125x5.0 SHS 200x6.0 SHS 250UC73 310UB46 200UC60 200x5.0 SHS 200x9.0 SHS 150x9.0 SHS 150x50x4.0 RHS 150x100x4.0 RHS 200x6.0 SHS 250 PFC 250PFC
JGC JOB CODE KBR JOB CODE CHD JOB CODE

LEVEL 00

LEVEL 00 VEHICLES
AA NO 11-APRIL-13 TENDER ISSUE DATE ISSUE PURPOSE SWS CKD DDG APP

bC6

bM3

bC6

bH 3

CL. BTM. CHORD

bS

bS

bR3

REVISIONS

SECTION
1 : 100

3
B24120

SECTION
1 : 100

7
B24121

05
bR 3

06
bR 3

07
bR 3

08

09
bS 1

10
hOR1

11
bS 3

ICHTHYS ONSHORE LNG FACILITIES


DRAWING TITLE

hOR1

bS

bS

bS3

bS3

bR5

CENTRAL CONTROL BUILDING STRUCTURAL BUILDING SECTIONS - EPC BUILDING WORKS - SHEET 1

bS

bC1

bC1

bC1

bC1

bC4

bC4

B bV

bC2

bV B

bH 1

bV

B4

SCALE COMPANY CONTRACT NO

1 : 100 2
LEICON REV

REVIEW CLASS

460UB67 410UB60 360UB 57 310UB32 125x5.0 SHS 150x5.0 SHS

LEVEL 00

LEVEL 00 VEHICLES
LEIGHTON DWG NO

Q1447-V-31D1-BLD-1-B24130
JKC DWG NO

AA
SIZE

SECTION
1 : 100

4
B24120

SECTION
1 : 100

8
B24121

V-31D1-BLD-1-B24130
COMPANY DWG NO

A1
COY REV

L290-DS-CSD-10005.001 13 14 15 16

7 8 9

10

11

12

6
PURLIN & GIRT SCHEDULE
bG1 bG2 bP1 bP2 bP3 bP4 bT1 bT2 Z20024 GIRTS AT 900 VERT. CTRS. + 1 ROW OF BRIDGING Z20019 GIRTS AT 900 VERT. CTRS. + 1 ROW OF BRIDGING Z25024 PURLINS AT 300 MAX. CTRS. + 2 ROWS OF BRIDGING Z25024 PURLINS AT 450 MAX. CTRS. + 2 ROWS OF BRIDGING Z25019 PURLINS AT 450 MAX. CTRS. + 1 ROW OF BRIDGING Z25024 PURLINS AT 900 MAX. CTRS. + 1 ROWS OF BRIDGING C25024 TRIMMER PURLIN C25015 TRIMMER PURLIN

8
STEEL FRAMING SCHEDULE MARK DESCRIPTION
BRACING bBR1 bBR4 bVB1 bVB2 bVB4 bVB5 30mm DIA. CROSS ROD BRACING 75x8.0 EA CROSS BRACING 30mm DIA. VERT. CROSS ROD BRACING 75x8.0 EA 150x5.0 SHS 100x8.0 EA VERT. CROSS BRACING

10
STEEL FRAMING SCHEDULE MARK DESCRIPTION
COLUMNS bC1 bC2 bC4 bC6 bC7 bC8 bC9 bC10 bM1 bM2 bM3 150x5.0 SHS 125x5.0 SHS 200x6.0 SHS 250UC73 310UB46 200UC60 200x5.0 SHS 200x9.0 SHS 150x9.0 SHS 150x50x4.0 RHS 150x100x4.0 RHS

11

12
STEEL FRAMING SCHEDULE MARK DESCRIPTION

13

14
BLD-1 Sub Contractor

15
ABN 98 000 893 667

16
LEIGHTON CONTRACTORS PTY LTD

NOTE:
A
FIRE SEPERATION REQUIREMENTS AND ASSOCIATED IMPACTS ON STRUCTURAL FRAMING STILL TO BE RESOLVED

STEEL FRAMING SCHEDULE MARK DESCRIPTION


STRUTS bS1 bS3 125x5.0 SHS 150x5.0 SHS
Architect

HEADS bH4 bH5 OUTRIGGERS hOR1 RAFTERS bR2 bR3 bR4 bR5

200x6.0 SHS 250 PFC 250PFC 460UB67 410UB60 360UB 57 310UB32

Level 6 HQ South Tower 520 Wickham Street Fortitude Valley QLD 4006 Australia PO Box 1077 Fortitude Valley QLD 4006 T +61 7 3215 4600 F +61 7 3215 4666 www.leightoncontractors.com.au

NOTE:
TR1 & TR2 - REFER SECTIONS ON DWG B24130

BVN Donovan Hill PO Box 801 Fortitude Valley QLD 4006 T +61 7 3852 2525 F +61 7 3852 2544 www.bvn.com.au
Structural/Civil/Mechanical/Electrical/Hydraulic Engineers

OPUS PO Box 99 Spring Hill QLD 4004 T +61 7 3838 2400 F +61 7 3838 2401 www.opus.com.au

G
10

PROVIDE bT2 PURLIN TRIMMER TO FULL LENGTH OF GABLE ROOF EDGE


3

H
10

8
B24130

7
B24130

6
B24130

L
TYP. EAVE PURLIN U.N.O. TO BE PROVIDED IN EACH BAY

ICHTHYS ONSHORE LNG FACILITIES

Darwin Australia

Subcontractor ISSUE PURPOSE:

FA A FA

FR B FR

FI N FI

FC F FC

AB CA AB NA

9 bC

bC

bVB5

bM

bC

hOR1

11
TYP. 3500 hOR1
bM 3

CTR RESULT CODE: NEXT STATUS:

bH5

bH5

bH5 hOR1 hOR1 hOR1 hOR1

bP2

bP3

bP1

bP1

bM

hOR1

Subcontractor RESUB / NEXTSUB DATE:


Approval or review hereunder shall not be construed to relieve Vendor / Subcontractor of his responsibilities and liability under the Contract.

1
bH4 bS1 bS1 B24140

4 bC

bS3

4 bC

bS3

6 bC

bS3

6 bC

bS3

6 bC

bS3

7 bC

CTR ORGANIZATION PJ DEPT RESPONSIBLE DEPT RELATED DEPT

DEPT NAME

SIGNATURE

bB

bP1

R4

R bB

bB

R4

R4 bB

bB R4

CTR REVIEW DATE: JOB NO 0-6037-2 REVIEW CLASS

1 bC

1 bC

bC

10

bVB2

bVB2

2
REV

SYSTEM NO - CLASS/DISC - TYPE - SERIAL NO

hOR1

D
bP2 TYP. EAVE PURLIN U.N.O. TO BE PROVIDED IN EACH BAY
4 bC

1 R bB

bB R1

R1 bB

bB R1

10
7 bC

CPY DOC NO

L290-DS-PAE-10102.002
PURCHASER ORDER NO - SERIAL NO

bS1

2 bC

CTR DOC NO

bS1

bS3

bS3

bS1

V-31D1-BLD-1-B24121

bP1

bS1

bS1

bP2

3000
bB R4

FOR CONTINUATION REFER DWG. B24120

bVB2

bR3

bR3

bR5

bR5

bR3

1 bC

1 bC 10 bC bM 2

hOR1

R1 bB

bB R

bB R

bB R1

R1 bB

bB R1

R1 bB

bB R1

bR5

bB R4

4 BR

bB R4

bVB4

bH4

TYP.

bP1

bH4

R4 bB

R1 bB

R1 bB

9
B24131
4 bC
R bB 1

bS1

bS1

bS3

bS3

bS1

7 bC

09

bS1

bS1

bP1

bM

2 4 bC

bS3 bVB1

4 bC

bS3

R4 bB
1 bC

bB R4

bB R4
1 bC

bM

1
R1 bB bB R1

9 bC

hOR1
1 bC

bS1

1 bC

bBR

b BR 1

bS3
bM 1

6 bC

bS3

6 bC

bS3

6 bC

bVB2
7 bC

bB R1

R bB

bB R1

hOR1

hOR1

hOR1

hOR1

hOR1

TYP.

3500

bP2

bP1

hOR1

bH4

R4 bB

bS3

08
3

bP3 bS1 bS1


bM 2 bM 3

bM

TYP. EAVE PURLIN U.N.O. TO BE PROVIDED IN EACH BAY

R4 bB

bB R4

bB R4
1 bC

bM

2 0

R4 bB

bR3

1 bC

hOR1

07

10
B24131

R4 bB

bB R4

bB R4
1 bC

bVB4

bH4

bS1

bS1

AA A NO

11-APRIL-13 TENDER ISSUE 13-MAR-13 30% ISSUE DATE

ISSUE PURPOSE

SWS SWS CKD

DDG DDG APP

R4 bB

bR3
1 bC

10 bC hOR1

REVISIONS

06

12
B24132

bP4 5000 bH4 bS1 bS1 TYP.

bP1

ICHTHYS ONSHORE LNG FACILITIES

STEELWORK NOTES:
1. REFER DRG Z24051 FOR GENERAL AND STEELWORK NOTES 2. ALL EXTERNAL AND EXPOSED STEELWORK TO BE HOT-DIP GALVANISED INCLUDING EXPOSED RAFTERS, BRACING AND COLUMNS IN EXTERNAL UNDERCROFT AREAS. 3. PROVIDE FLY BRACING TO ALL RAFTERS AND UB SECTION COLUMNS AT 3.0m CENTRES TYPICALLY U.N.O. 4. BASE FIXINGS - ALLOW FOR 4min x CAST-IN HOLD DOWN BOLTS TO EACH COLUMN (xC). ALLOW FOR 2min x CHEMSET ANCHORS TO EACH MULLION (xM). 5. ALL RAFTERS TO BE SPLICED AT 18m MAXIMUM LENGTH OR AT LOCATIONS AS INDICATED ON THE DRAWINGS. SPLICE TO BE FULL MOMENT BOLTED SPLICE CONNECTIONS. 6. ALL RAFTER/ UB COLUMN CONNECTIONS TO BE BOLTED END PLATE MOMENT CONNECTIONS. 7. DESIGN IS BASED ON THE FOLLOWING SHEETING PROFILES: - ROOF SHEETING - TRIMDEK 0.48BMT - CREST FASTENED WITH CYCLONIC WASHERS IN ACCORDANCE WITH MANUFACTURERS SPECIFICATION. - WALL CLADDING SPANDEK 0.48BMT VALLEY FASTENED. 8. WALL STUD FRAMING IS SHOWN INDICATIVELY ONLY AND IS TO BE DESIGNED AND CERTIFIED BY OTHERS. 9. STUDS TO BE DESIGNED TO THE WINDLOAD CRITERIA AS SPECIFIED IN THE GENERAL NOTES ON DWG Z24051. WINDLOADING TO BE CALCULATED IN ACCORDANCE WITH AS1170.2. 10. WALL STUDS - MAXIMUM DEFLECTION CRITERIA UNDER V25 WIND SPEED HEIGHT/240 11. MINIMUM STUD BASE METAL THICKNESS 1.5mm.

DRAWING TITLE

R4 bB

bB R4

bB R4
9 bC bM 2

CENTRAL CONTROL BUILDING - ROOF STEELWORK FRAMING PLAN - EPC BUILDING WORKS - SHEET 2

R4 bB

bR3

9 bC

hOR1

1 bC

05

bS1

bS1

bM

SCALE COMPANY CONTRACT NO

1 : 100 2
LEICON REV

REVIEW CLASS

R4 bB

bB R4
9 bC

JGC JOB CODE

KBR JOB CODE

CHD JOB CODE

LEIGHTON DWG NO

bR2 bVB5

1 bC

Q1447-V-31D1-BLD-1-B24121
JKC DWG NO

AA
SIZE

hOR1

bVB5

04

V-31D1-BLD-1-B24121
COMPANY DWG NO

A1
COY REV

FOR CONTINUATION REFER DWG. B24123


1 2 3 4 5 6 7 8 9 10 11 12 13 14

L290-DS-PAE-10102.002 15 16

6
PURLIN & GIRT SCHEDULE
bG1 bG2 bP1 Z20024 GIRTS AT 900 VERT. CTRS. + 1 ROW OF BRIDGING Z20019 GIRTS AT 900 VERT. CTRS. + 1 ROW OF BRIDGING Z25024 PURLINS AT 300 MAX. CTRS. + 2 ROWS OF BRIDGING Z25024 PURLINS AT 450 MAX. CTRS. + 2 ROWS OF BRIDGING Z25019 PURLINS AT 450 MAX. CTRS. + 1 ROW OF BRIDGING Z25024 PURLINS AT 900 MAX. CTRS. + 1 ROWS OF BRIDGING C25024 TRIMMER PURLIN C25015 TRIMMER PURLIN

8
STEEL FRAMING SCHEDULE MARK DESCRIPTION
BRACING bBR1 bBR4 bVB1 bVB2 bVB4 bVB5 30mm DIA. CROSS ROD BRACING 75x8.0 EA CROSS BRACING 30mm DIA. VERT. CROSS ROD BRACING 75x8.0 EA 150x5.0 SHS 100x8.0 EA VERT. CROSS BRACING

10
STEEL FRAMING SCHEDULE MARK DESCRIPTION
COLUMNS bC1 bC2 bC4 bC6 bC7 bC8 bC9 bC10 bM1 bM2 bM3 150x5.0 SHS 125x5.0 SHS 200x6.0 SHS 250UC73 310UB46 200UC60 200x5.0 SHS 200x9.0 SHS 150x9.0 SHS 150x50x4.0 RHS 150x100x4.0 RHS

11

12
STEEL FRAMING SCHEDULE MARK DESCRIPTION

13

14
BLD-1 Sub Contractor

15
ABN 98 000 893 667

16
LEIGHTON CONTRACTORS PTY LTD

NOTE:
A
FIRE SEPERATION REQUIREMENTS AND ASSOCIATED IMPACTS ON STRUCTURAL FRAMING STILL TO BE RESOLVED

STEEL FRAMING SCHEDULE MARK DESCRIPTION


STRUTS bS1 bS3 125x5.0 SHS 150x5.0 SHS
Architect

NOTE:
REFER TO DWG B24121 FOR STEELWORK NOTES.

bP2 bP3 bP4 bT1 bT2

HEADS bH4 bH5 OUTRIGGERS hOR1 RAFTERS bR2 bR3 bR4 bR5

200x6.0 SHS 250 PFC 250PFC 460UB67 410UB60 360UB 57 310UB32

Level 6 HQ South Tower 520 Wickham Street Fortitude Valley QLD 4006 Australia PO Box 1077 Fortitude Valley QLD 4006 T +61 7 3215 4600 F +61 7 3215 4666 www.leightoncontractors.com.au

NOTE:
TR1 & TR2 - REFER SECTIONS ON DWG B24130

BVN Donovan Hill PO Box 801 Fortitude Valley QLD 4006 T +61 7 3852 2525 F +61 7 3852 2544 www.bvn.com.au
Structural/Civil/Mechanical/Electrical/Hydraulic Engineers

OPUS PO Box 99 Spring Hill QLD 4004 T +61 7 3838 2400 F +61 7 3838 2401 www.opus.com.au

A
bM 2 10 bC

PROVIDE bT2 PURLIN TRIMMER TO FULL LENGTH OF GABLE ROOF EDGE


bM 3 2 bM bVB5

B
10 bC

C
9 bC

5
B24130

E
2 2

G
10 bC 3

ICHTHYS ONSHORE LNG FACILITIES

Darwin Australia

11
C

bR3 bH5 bP3

10 bC

9 bC

bM

bM

bR3 bH5 bP3

9 bC

bVB5

bM

Subcontractor ISSUE PURPOSE: CTR RESULT CODE: NEXT STATUS:

FA A FA

FR B FR

FI N FI

FC F FC

AB CA AB NA

hOR1 5000 bP1

bH5

bH5

bH5

bH5

bH5

bH5

Subcontractor RESUB / NEXTSUB DATE:


Approval or review hereunder shall not be construed to relieve Vendor / Subcontractor of his responsibilities and liability under the Contract.

bB R4

R bB

bB R4

R4 bB

bB R4

R4 bB

bB R4

R4 bB

bB R4

bB

R4

bB

R4

R4 bB

CTR ORGANIZATION PJ DEPT RESPONSIBLE DEPT RELATED DEPT

DEPT NAME

SIGNATURE

bS3

bVB4

bS3

bS1

bS1

bS1

bS1

bH4

bS1

bB

R4

R bB

bB

bS1

R4 bB

R4

R4 bB

CTR REVIEW DATE: JOB NO 0-6037-2 REVIEW CLASS

10
D
TYP. EAVE PURLIN U.N.O. TO BE PROVIDED IN EACH BAY

10 bC

1 bC

bR3

1 bC

1 bC

9 bC

bR3

1 bC

1 bC

2
REV

SYSTEM NO - CLASS/DISC - TYPE - SERIAL NO

hOR1

CPY DOC NO

L290-DS-PAE-10102.001
PURCHASER ORDER NO - SERIAL NO

bP2 bS1 bS1 bS3 bS1 bS3 bS1 bS1 bS1

CTR DOC NO

V-31D1-BLD-1-B24120

3500 TYP. bVB4 bH4


R bB 4

bB R4

E
9
B24131

09

1 bC

1 bC

bR3

1 bC

1 bC

1 bC

bR3

1 bC

1 bC

hOR1

08

1 bC

1 bC

bR3

1 bC

1 bC

1 bC

bR3

1 bC

1 bC

hOR1

bH4

bP4 bS1 bS1 bS3 bS3 bS1


bS1

B24130

B24130

B24130

B24130

bM

2 9 bC 1 bC bR3 8 bC

10
B24131

07

bR3 bR4(u)

8 bC

bR3 bVB5 bR4(u)

8 bC

bR4

1 bC

bR3

1 bC

hOR1

bVB4

bH4

bS1

bS1

bB R4

R bB

bB R4

R1 bB
1 bC bR3

bB R

R1 bB

bB R1

bS3

R4 bB
1 bC

bB R4
1 bC

bS1

bB R4

bM

2
R bB 4

1
bB R4

4
R4 bB

bB R4

bB R4

R bB

bB R4

R4 bB

bB R4

FOR CONTINUATION REFER DWG. B24121


AA A NO 11-APRIL-13 TENDER ISSUE 13-MAR-13 30% ISSUE DATE

bB R4

R4 B b

R4 bB

R4 bB

bB R4

bB R4

bB R4

bB R4

R4 bB

bB R4

R4 bB

bB R4

bB R4

R4 bB

bB R4

bVB4

bH4

bS1

bS1

bS3

bS1

bS1

bS3

bVB4

bS3

bS1

ISSUE PURPOSE

SWS SWS CKD

DDG DDG APP

12
B24132

06

9 bC

bS3(u)

bR3

bS3(u)

bS3(u)

bR3

bS3(u)

bS3(u)

bR3
1 bC

REVISIONS

hOR1 bP4 4000 TR1 TR2 TR2 bVB4 bH4 bS1 bS3 bP3 bP4 bP4

I ICHTHYS ONSHORE LNG FACILITIES


bS1 bS1
DRAWING TITLE

05
J

9 bC

1 bC bR3

bS3(u)

bR3

bS3(u)

bS3(u)

bR3

bS3(u)

bS3(u)

1 bC

bR3
1 bC

9 bC bM 2

hOR1

bB R4

bB

R4

bB R4

R1 bB

bB R

R4 bB

bB R4

CENTRAL CONTROL BUILDING - ROOF STEELWORK FRAMING PLAN - EPC BUILDING WORKS - SHEET 1

bH4

bS1

bS1

bS3

bS1

bM

2
COMPANY CONTRACT NO

SCALE

1 : 100 2
LEICON REV

REVIEW CLASS

R4 bB

bB R4

R1 bB
1 bC bR3 8 bC

bB R

R1 bB

bB R1

R4 bB
8 bC 1 bC 1 bC

bB R4
9 bC

JGC JOB CODE

KBR JOB CODE

CHD JOB CODE

LEIGHTON DWG NO

04

9 bC

bR4(u) bR3

8 bC

bR4(u) bR3

bR2 bVB5

hOR1

Q1447-V-31D1-BLD-1-B24120
JKC DWG NO

AA
SIZE

hOR1

bVB5

V-31D1-BLD-1-B24120
COMPANY DWG NO

A1
COY REV

FOR CONTINUATION REFER DWG. B24122


1 2 3 4 5 6 7 8 9 10 11 12 13 14

L290-DS-PAE-10102.001 15 16

10

11

12

13

14
BLD-1 Sub Contractor

15
ABN 98 000 893 667

16
LEIGHTON CONTRACTORS PTY LTD

WAREHOUSE STEEL FRAMING SCHEDULE MARK DESCRIPTION

CA

CB

CC

CD

CE

CF

CG

aR3

aR3

B
aR3

C
LEVEL 00

ELEVATION ON GRID 01
D
WAREHOUSE PURLIN & GIRTS SCHEDULE
aG1 aG2 aG3 aP1 aP2 aP3 aP4 aP5 aP6 aP7 aT1 aT2 Z20019 AT 750 MAX CTRS + 1 ROW BRIDGING Z20024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20019 AT 1500 MAX CTRS + 1 ROW BRIDGING Z25019 AT 750 MAX CTRS + 1 ROW BRIDGING Z25024 AT 1500 MAX CTRS + 1 ROW BRIDGING Z25019 AT 1500 MAX CTRS + 1 ROW BRIDGING Z25024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20019 AT 750 MAX CTRS + 1 ROW BRIDGING C20015 TRIMMER PURLIN C25019 TRIMMER PURLIN SCALE 1 : 100 at A1.

BEAMS aB1 aB2 BRACING aBR1 aBR2 aVB1 aVB2 COLUMNS aC1 aC2 aC3 aC4 aC5 aC6 HEADS aH1 aH2 aH3 aH4 aH5 MULLIONS aM1 aM2 aM3 aM4 RAFTERS aR1 aR2 aR3 aR4 STRUTS aS1 aS2 aS3 aS4

460UB82 310UB46 125x8.0 EA 20mm DIA. CROSS ROD BRACING 125x8.0 EA VERT. CROSS BRACING 20mm DIA. VERT. CROSS ROD BRACING 610UB101 460UB67 410UB54 200x6.0 SHS 150x5.0 SHS 310UB40 250x150x5.0 RHS (ON FLAT) 150x100x5.0 RHS (ON FLAT) 200x6.0 SHS 150x5.0 SHS 200x100x5.0 RHS (ON FLAT) 200PFC 150x100x4.0 RHS 150x50x4.0 RHS 250PFC 610UB101 460UB67 310UB32 300PFC 150x5.0 SHS 125x5.0 SHS 89x3.5 SHS 200x5.0 SHS
Architect

Level 6 HQ South Tower 520 Wickham Street Fortitude Valley QLD 4006 Australia PO Box 1077 Fortitude Valley QLD 4006 T +61 7 3215 4600 F +61 7 3215 4666 www.leightoncontractors.com.au

BVN Donovan Hill PO Box 801 Fortitude Valley QLD 4006 T +61 7 3852 2525 F +61 7 3852 2544 www.bvn.com.au
Structural/Civil/Mechanical/Electrical/Hydraulic Engineers

OPUS PO Box 99 Spring Hill QLD 4004 T +61 7 3838 2400 F +61 7 3838 2401 www.opus.com.au

ICHTHYS ONSHORE LNG FACILITIES

Darwin Australia

Subcontractor ISSUE PURPOSE: CTR RESULT CODE: NEXT STATUS:

FA A FA

FR B FR

FI N FI

FC F FC

AB CA AB NA

aC3

aC3

aC3

aC3

aC3

aC3

aC3

aH 2

aH 4

Subcontractor RESUB / NEXTSUB DATE:


Approval or review hereunder shall not be construed to relieve Vendor / Subcontractor of his responsibilities and liability under the Contract.

CTR ORGANIZATION PJ DEPT RESPONSIBLE DEPT RELATED DEPT

DEPT NAME

SIGNATURE

CTR REVIEW DATE: JOB NO CPY DOC NO 0-6037-2 REVIEW CLASS

2
REV

SYSTEM NO - CLASS/DISC - TYPE - SERIAL NO

L290-DS-PAE-10113.002
PURCHASER ORDER NO - SERIAL NO

CTR DOC NO

V-31D1-BLD-1-A24141

35

33

32

31

29

27

25

23

21

aS1

aS1

aS2

aS2

aS2

aS1

aS1

aH1
B1 aV
aV B1

B1 aV

aV B1

B1 aV

aV B1

B1 aV

aV B1

aS1

LEVEL 01 A20011 aB1 aC1 aC1 aC2


B aV 1

aB2 aC1

aB2 aC1
aS 4

aB2 aC1

aB2 aC1
aS 4

aB2 aC1

aM4

aM4

aH4 aM3
aV B1

aH4 aM3

aH4 aM3 aM3

aH4

aH4 aM3

aH4

aH4

aH 4

aM3

aM2

aM3

aM3

aM3

G
LEVEL 00

aH2

aH4

aH4

aH4

ELEVATION ON GRID CA
SCALE 1 : 100 at A1.

21 19
I

aM3

AA NO

11-APRIL-13 TENDER ISSUE DATE

ISSUE PURPOSE

SWS CKD

DDG APP

REVISIONS

17

15

13

11

09

07

05

03

01
ICHTHYS ONSHORE LNG FACILITIES
DRAWING TITLE

aV B1

aS1

aS1

aS2

aS2

aS2

aS2

aS2

aS1

aS1

aS2 LEVEL 01 A20011

aR 3

WAREHOUSE - STRUCTURAL WALL ELEVATIONS - EPC BUILDING WORKS SHEET 2

aR 3

aR 3

aR 3

aR 3

aR 3

aH5 aC1

aS3

aR 3

aS3 aH5

aC1

aC1

aC1

aC1

aC1

aC1

aC1

aC1

aC1

aM1

aM1

aM1

aM1

aH4

aH4
B aV 1 aV B

aH4

aH4

aH4

aH4

aH4
1 B aV aV B

aH2
SCALE COMPANY CONTRACT NO

aC3

aR 3

1 : 100 2
LEICON REV

REVIEW CLASS

1
JGC JOB CODE KBR JOB CODE CHD JOB CODE

LEVEL 00
LEIGHTON DWG NO

Q1447-V-31D1-BLD-1-A24141

AA
SIZE

ELEVATION ON GRID CA
SCALE 1 : 100 at A1.

JKC DWG NO

V-31D1-BLD-1-A24141
COMPANY DWG NO

A1
COY REV

L290-DS-PAE-10113.002 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

10

11

12

13

14
BLD-1 Sub Contractor

15
ABN 98 000 893 667

16
LEIGHTON CONTRACTORS PTY LTD

WAREHOUSE STEEL FRAMING SCHEDULE MARK DESCRIPTION

CG

CF

CE

CD

CC

CB

CA

aR3

aR3

B
B2 aV

aH 1

aV B2

B2 aV

aV B2

aS1

aS1

aH4
B2 aV
aV B2 B2 aV

aH4
aV B2

LEVEL 00

BEAMS aB1 aB2 BRACING aBR1 aBR2 aVB1 aVB2 COLUMNS aC1 aC2 aC3 aC4 aC5 aC6 HEADS aH1 aH2 aH3 aH4 aH5 MULLIONS aM1 aM2 aM3 aM4 RAFTERS aR1 aR2 aR3 aR4 STRUTS aS1 aS2 aS3 aS4

460UB82 310UB46 125x8.0 EA 20mm DIA. CROSS ROD BRACING 125x8.0 EA VERT. CROSS BRACING 20mm DIA. VERT. CROSS ROD BRACING 610UB101 460UB67 410UB54 200x6.0 SHS 150x5.0 SHS 310UB40 250x150x5.0 RHS (ON FLAT) 150x100x5.0 RHS (ON FLAT) 200x6.0 SHS 150x5.0 SHS 200x100x5.0 RHS (ON FLAT) 200PFC 150x100x4.0 RHS 150x50x4.0 RHS 250PFC 610UB101 460UB67 310UB32 300PFC 150x5.0 SHS 125x5.0 SHS 89x3.5 SHS 200x5.0 SHS
Architect

Level 6 HQ South Tower 520 Wickham Street Fortitude Valley QLD 4006 Australia PO Box 1077 Fortitude Valley QLD 4006 T +61 7 3215 4600 F +61 7 3215 4666 www.leightoncontractors.com.au

BVN Donovan Hill PO Box 801 Fortitude Valley QLD 4006 T +61 7 3852 2525 F +61 7 3852 2544 www.bvn.com.au
Structural/Civil/Mechanical/Electrical/Hydraulic Engineers

OPUS PO Box 99 Spring Hill QLD 4004 T +61 7 3838 2400 F +61 7 3838 2401 www.opus.com.au

aH 1

ICHTHYS ONSHORE LNG FACILITIES

Darwin Australia

Subcontractor ISSUE PURPOSE: CTR RESULT CODE: NEXT STATUS:

FA A FA

FR B FR

FI N FI

FC F FC

AB CA AB NA

aM4

aC2

aM4

aC2

aC2

aC2

aC2

aC2

aC2

Subcontractor RESUB / NEXTSUB DATE:


Approval or review hereunder shall not be construed to relieve Vendor / Subcontractor of his responsibilities and liability under the Contract.

CTR ORGANIZATION PJ DEPT RESPONSIBLE DEPT RELATED DEPT

DEPT NAME

SIGNATURE

aM3 aM3

aM3

aM3

CTR REVIEW DATE: JOB NO CPY DOC NO 0-6037-2 REVIEW CLASS

2
REV

SYSTEM NO - CLASS/DISC - TYPE - SERIAL NO

L290-DS-PAE-10113.001
PURCHASER ORDER NO - SERIAL NO

CTR DOC NO

V-31D1-BLD-1-A24140

ELEVATION ON GRID 35
SCALE 1 : 100 at A1.

21
E

01

03

05

07

09

11

13

15

17

19

aS2

aS2

aS2

aS2

aS2

F
aR 3
aV B

aS3 aH5

aR 3

aR 3

aH5 aC1 Z20019 AT 750 MAX CTRS + 1 ROW BRIDGING Z20024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20019 AT 1500 MAX CTRS + 1 ROW BRIDGING Z25019 AT 750 MAX CTRS + 1 ROW BRIDGING Z25024 AT 1500 MAX CTRS + 1 ROW BRIDGING Z25019 AT 1500 MAX CTRS + 1 ROW BRIDGING Z25024 AT 750 MAX CTRS + 1 ROW BRIDGING Z20019 AT 750 MAX CTRS + 1 ROW BRIDGING C20015 TRIMMER PURLIN C25019 TRIMMER PURLIN aM1 aM1

aC1

aC3

aC1

aC1

aC1

aC1

aC1

aC1

aC1

aM1

aM1

aH4

aH4
B aV aV B 1 1

aH4

aH4

aH4

aH4

aH4

aH4

LEVEL 00

ELEVATION ON GRID CG
SCALE 1 : 100 at A1.

19

21

23

25

27

29

31

33

35

WAREHOUSE PURLIN & GIRTS SCHEDULE


aG1 aG2 aG3 aP1 aP2 aP3 aP4 aP5 aP6 aP7 aT1 aT2
AA NO 11-APRIL-13 TENDER ISSUE DATE ISSUE PURPOSE SWS CKD DDG APP

aC1

aR 3

aS1

aS1

aS1

aS1

aS1

aR 4

B aV 1

REVISIONS

aS1

aS1

aS1

aS1

aS1

aS1

I
aH1
aR 3 aR 3 aR 3 aR 3 aR 3 aR 3

ICHTHYS ONSHORE LNG FACILITIES


DRAWING TITLE

aS1
aR 3

aR 3

B1 aV

aV B1

B1 aV

aV B1

B1 aV

aV B1

B1 aV

aV B1

aR 4

aH5 aC1 aC1

aC1

aC1

aC1

aC1

aM4

aM1

aM1

aM1

aM1

aH4

aH4

aH4

aH4

aH4

aH aM4 4

aC1

B aV

aC1

aV B

aB1

aB2 aH5

aB2

aB2

aB2

aC2

WAREHOUSE - STRUCTURAL WALL ELEVATIONS - EPC BUILDING WORKS SHEET 1

SCALE

1 : 100 2
LEICON REV

aM3

aM3

aM3

aM3

aM3 aM3

aM3

aM3

aM3

aM3

aM3 aM3

aH4

4 aS

aM3

4 aS

COMPANY CONTRACT NO

REVIEW CLASS

JGC JOB CODE

KBR JOB CODE

CHD JOB CODE

LEVEL 00
LEIGHTON DWG NO

Q1447-V-31D1-BLD-1-A24140

AA
SIZE

ELEVATION ON GRID CG
SCALE 1 : 100 at A1.

JKC DWG NO

V-31D1-BLD-1-A24140
COMPANY DWG NO

A1
COY REV

L290-DS-PAE-10113.001 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

10

11

12

13

14
BLD-1 Sub Contractor

15
ABN 98 000 893 667

16
LEIGHTON CONTRACTORS PTY LTD

WAREHOUSE STEEL FRAMING SCHEDULE MARK DESCRIPTION

CA

CB

CC
aR1 aR2

CD
aS 1
aR1

CE

CF

CG

aR2

B
aR3

C
LEVEL 00

SECTION
1 : 100

4
A24121

BEAMS aB1 aB2 BRACING aBR1 aBR2 aVB1 aVB2 COLUMNS aC1 aC2 aC3 aC4 aC5 aC6 HEADS aH1 aH2 aH3 aH4 aH5 MULLIONS aM1 aM2 aM3 aM4 RAFTERS aR1 aR2 aR3 aR4 STRUTS aS1 aS2 aS3 aS4

460UB82 310UB46 125x8.0 EA 20mm DIA. CROSS ROD BRACING 125x8.0 EA VERT. CROSS BRACING 20mm DIA. VERT. CROSS ROD BRACING 610UB101 460UB67 410UB54 200x6.0 SHS 150x5.0 SHS 310UB40 250x150x5.0 RHS (ON FLAT) 150x100x5.0 RHS (ON FLAT) 200x6.0 SHS 150x5.0 SHS 200x100x5.0 RHS (ON FLAT) 200PFC 150x100x4.0 RHS 150x50x4.0 RHS 250PFC 610UB101 460UB67 310UB32 300PFC 150x5.0 SHS 125x5.0 SHS 89x3.5 SHS 200x5.0 SHS
Architect

Level 6 HQ South Tower 520 Wickham Street Fortitude Valley QLD 4006 Australia PO Box 1077 Fortitude Valley QLD 4006 T +61 7 3215 4600 F +61 7 3215 4666 www.leightoncontractors.com.au

BVN Donovan Hill PO Box 801 Fortitude Valley QLD 4006 T +61 7 3852 2525 F +61 7 3852 2544 www.bvn.com.au
Structural/Civil/Mechanical/Electrical/Hydraulic Engineers

aS

aS

OPUS PO Box 99 Spring Hill QLD 4004 T +61 7 3838 2400 F +61 7 3838 2401 www.opus.com.au

ICHTHYS ONSHORE LNG FACILITIES

Darwin Australia

aC4

Subcontractor ISSUE PURPOSE: CTR RESULT CODE: NEXT STATUS:

FA A FA

FR B FR

FI N FI

FC F FC

AB CA AB NA

aC1

aC1

Subcontractor RESUB / NEXTSUB DATE:


Approval or review hereunder shall not be construed to relieve Vendor / Subcontractor of his responsibilities and liability under the Contract.

CTR ORGANIZATION PJ DEPT RESPONSIBLE DEPT RELATED DEPT

DEPT NAME

SIGNATURE

CTR REVIEW DATE: JOB NO CPY DOC NO 0-6037-2 REVIEW CLASS

2
REV

SYSTEM NO - CLASS/DISC - TYPE - SERIAL NO

L290-DS-PAE-10008.002
PURCHASER ORDER NO - SERIAL NO

CTR DOC NO

V-31D1-BLD-1-A24131

CA

CB

CC
1
aR1

CD
aS 1
aR1

CE
1

CF

CG

aS

aS

aS

aS

aR2

aR2

aS

aS

aR3

aR3

aC1

aC4

LEVEL 00

SECTION
1 : 100

5
A24122

aC1

AA NO

11-APRIL-13 TENDER ISSUE DATE

ISSUE PURPOSE

SWS CKD

DDG APP

REVISIONS

I ICHTHYS ONSHORE LNG FACILITIES


DRAWING TITLE

WAREHOUSE - STRUCTURAL BUILDING SECTIONS - EPC BUILDING WORKS SHEET 2 J


SCALE COMPANY CONTRACT NO

1 : 100 2
LEICON REV

REVIEW CLASS

JGC JOB CODE

KBR JOB CODE

CHD JOB CODE

LEIGHTON DWG NO

Q1447-V-31D1-BLD-1-A24131
JKC DWG NO

AA
SIZE

V-31D1-BLD-1-A24131
COMPANY DWG NO

A1
COY REV

L290-DS-PAE-10008.002 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

10

11

12

13

14
BLD-1 Sub Contractor

15
ABN 98 000 893 667

16
LEIGHTON CONTRACTORS PTY LTD

CA
A

CB
aR2

CC
aR1

CD
aS 1
aR1

CE
aR2

CF

CG

CH

NOTES:
1. REFER TO DWG. A24120 FOR STEEL MEMBER SCHEDULE

Level 6 HQ South Tower 520 Wickham Street Fortitude Valley QLD 4006 Australia PO Box 1077 Fortitude Valley QLD 4006 T +61 7 3215 4600 F +61 7 3215 4666 www.leightoncontractors.com.au
Architect

aS

aS

BVN Donovan Hill PO Box 801 Fortitude Valley QLD 4006 T +61 7 3852 2525 F +61 7 3852 2544 www.bvn.com.au
Structural/Civil/Mechanical/Electrical/Hydraulic Engineers

aC4

OPUS PO Box 99 Spring Hill QLD 4004 T +61 7 3838 2400 F +61 7 3838 2401 www.opus.com.au

B
aR3

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

LEVEL 01 A20011

ICHTHYS ONSHORE LNG FACILITIES

aB1

aB1
Subcontractor ISSUE PURPOSE: CTR RESULT CODE: X

Darwin Australia

FA A FA

FR B FR

FI N FI

FC F FC

AB CA AB NA

aH 4

aC1

aC4

aC4

aC4

aC4

aC4

aC1

aC5

NEXT STATUS:

aM3

aM3

C
LEVEL 00

aH 4

Subcontractor RESUB / NEXTSUB DATE:


Approval or review hereunder shall not be construed to relieve Vendor / Subcontractor of his responsibilities and liability under the Contract.

CTR ORGANIZATION PJ DEPT RESPONSIBLE DEPT RELATED DEPT

DEPT NAME

SIGNATURE

aH 2

CTR REVIEW DATE: JOB NO 0-6037-2 REVIEW CLASS

2
REV

SECTION
D
1 : 100

1
A24100

SYSTEM NO - CLASS/DISC - TYPE - SERIAL NO

CPY DOC NO

L290-DS-PAE-10008.001
PURCHASER ORDER NO - SERIAL NO

CTR DOC NO

V-31D1-BLD-1-A24130

CA
E
1

CB
aS
aR2

CC
1
aR1

CD
aS 1
aR1

CE
aS 1
aR2

CF
aS 1

CG

CH

aS

aS

aC6

aC6

aC6

aC6

aS

aS

aS

aS

aR4

aR4

aC6

aS

F
LEVEL 01 A20011

aS

aS

aS

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aB

aH2 aC1 aH2 aM2 aM2

aH2 aM1 aH4 aC1 aC5

aC4

aC4

aC4

aC4

aH 4

aM2

aM2

aM2

LEVEL 00

SECTION
H
1 : 100

2
A24121

aH 4

aM2

aC4

aH 5

aS

aR3

AA NO

11-APRIL-13 TENDER ISSUE DATE

ISSUE PURPOSE

SWS CKD

DDG APP

REVISIONS

CA
I

CB

CC
1
aR1

CD
aS 1
aR1

CE
1 aS

CF

CG

CH
ICHTHYS ONSHORE LNG FACILITIES

aS

aS

aS

aR2

aR2

aS

aS

DRAWING TITLE

aR3

aC1

aC1

J
aH 4

aC4

aM1 aH4

aH 5

WAREHOUSE - STRUCTURAL BUILDING SECTIONS - EPC BUILDING WORKS SHEET 1

aC5

SCALE COMPANY CONTRACT NO

1 : 100 2
LEICON REV

REVIEW CLASS

LEVEL 00

JGC JOB CODE

KBR JOB CODE

CHD JOB CODE

LEIGHTON DWG NO

Q1447-V-31D1-BLD-1-A24130
JKC DWG NO

AA
SIZE

SECTION
1 : 100

3
A24121

V-31D1-BLD-1-A24130
COMPANY DWG NO

A1
COY REV

L290-DS-PAE-10008.001 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

5
8.

10

11

12

13

14
BLD-1 Sub Contractor

15
ABN 98 000 893 667

16
LEIGHTON CONTRACTORS PTY LTD

GENERAL
1.

FOOTINGS
1. AN ALLOWABLE BEARING PRESSURE IN NATURAL GROUND OF 100 kPa HAS BEEN ASSUMED IN THE DESIGN OF FOOTINGS. THE SUBCONTRACTOR SHALL ENGAGE A REGISTERED GEOTECHNICAL ENGINEER TO VERIFY THAT THE GROUND AT EACH FOOTING IS CAPABLE OF CARRYING THIS PRESSURE. ALL FOOTING EXCAVATIONS SHALL BE CLEANED OF LOOSE MATERIAL AND WATER. ALL FOUNDATION MATERIAL SHALL BE INSPECTED BY THE STRUCTURAL ENGINEER BEFORE ANY CONCRETE IS PLACED. WHERE VERIFIED FOUNDATION MATERIAL IS LOWER THAN THE UNDERSIDE OF FOOTINGS AS DETAILED, BACKFILL ADDITIONAL EXCAVATION WITH GRADE N20 CONCRETE. SIDES OF FOOTINGS SHALL BE FORMED AS NECESSARY WHEN EXCAVATED FACE IS NOT STABLE. ALL WALLS AND COLUMNS SHALL BE CONCENTRIC WITH SUPPORTING FOOTINGS UNLESS OTHERWISE NOTED ON THE DRAWINGS. UNLESS APPROVED BY THE STRUCTURAL ENGINEER, EXCAVATIONS SHALL NOT EXTEND BELOW A LINE DIPPING AT 45 DEGREES AND AWAY FROM THE NEAREST UNDERSIDE CORNER OF ANY FOOTINGS A PRELIMINARY GEOTECHNICAL STUDY FOR THE ORIGINAL SITE HAS BEEN PREPARED BY COFFEY GEOTECHNICS REPORT No. 12128AA-AB AND DATED 5TH FEBRURARY 2013. THE SUBCONTRACTOR SHALL ENSURE THAT THEY ARE FAMILIAR WITH THE CONTENTS OF THIS REPORT. ALL FOOTING EXCAVATIONS SHALL BE MAINTAINED FREE OF WATER BY PROVISION OF RELIEF DRAINS, OR DRAINAGE TO SUITABLE COLLECTION SUMPS FOR REMOVAL BY PUMPING OR MANUAL MEANS. ALL REINFORCING STEEL IS TO BE MANUFACTURED AND SUPPLIED BY ORGANISATIONS CERTIFIED BY ACRS (AUSTRALIAN CERTIFICATION AUTHORITY FOR REINFORCING STEELS LTD) OR AN EQUIVALENT THIRD PARTY PRODUCT CERTIFICATION SYSTEM APPROVED IN WRITING BY THE ENGINEER. EVIDENCE OF COMPLIANCE WITH THIS REQUIREMENT IS TO BE SUPPLIED TO THE ENGINEER. REINFORCEMENT SYMBOLS: RPLAIN ROUND BAR GRADE R250N TO AS 4671 SDEFORMED BAR GRADE D250N TO AS 4671 NDEFORMED BAR GRADE D500N TO AS 4671 SL/RL- DEFORMED WIRE REINFORCING MESH GRADE D500L TO AS 4671 WCOLD DRAWN ROUND WIRE GRADE R500L TO AS 4671 THE NUMBER FOLLOWING THE BAR SYMBOL IS THE NOMINAL BAR DIAMETER IN MILLIMETRES. 24. SPLICES IN REINFORCEMENT SHALL BE MADE ONLY IN THE POSITION SHOWN. WRITTEN APPROVAL BY THE STRUCTURAL ENGINEER SHALL BE OBTAINED FOR ANY OTHER SPLICES. 25. WELDING OF REINFORCEMENT WILL BE PERMITTED ONLY AFTER APPROVAL BY THE STRUCTURAL ENGINEER AND IN ACCORDANCE WITH THE CONCRETE SPECIFICATION. 26. REINFORCEMENT SHALL BE BENT COLD IN ACCORDANCE WITH AS 3600 EXCEPT WHERE APPROVED BY THE STRUCTURAL ENGINEER. NO RE-BENDING SHALL BE PERMITTED UNLESS APPROVED BY THE STRUCTURAL ENGINEER.

STEELWORK
1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS/NZS 1163, 3678, 3679.1, 3679.2 AND AS 4100. ALL STRUCTURAL STEEL IS TO BE MANUFACTURED AND SUPPLIED BY ORGANISATIONS CERTIFIED BY ACRS (AUSTRALIAN CERTIFICATION AUTHORITY FOR REINFORCING STEELS LTD) OR AN EQUIVALENT THIRD PARTY PRODUCT CERTIFICATION SYSTEM APPROVED IN WRITING BY THE ENGINEER. EVIDENCE OF COMPLIANCE WITH THIS REQUIREMENT IS TO BE SUPPLIED TO THE ENGINEER. GP (GENERAL PURPOSE) CATEGORY WELDS SHALL BE USED FOR WELDING OF ALL STRUCTURAL STEELWORK UNLESS NOTED OTHERWISE. ALL WELDS 6 C.F.W. ALL AROUND, UNLESS NOTED OTHERWISE. C.P.B.W. INDICATES COMPLETE PENETRATION BUTT WELD. WELDING SHALL BE PERFORMED BY A QUALIFIED WELDER IN ACCORDANCE WITH AS 1554 PART 1. ALL BOLTS TO BE M20 8.8/S UNLESS NOTED OTHERWISE. PROVIDE 10mm THICK M.S. PLATES THROUGHOUT, UNLESS NOTED OTHERWISE. BOLT TYPES (AND DESIGNATIONS, WHERE USED) SHALL BE AS FOLLOWS: 4.6/S - COMMERCIAL BOLTS TO AS 1111 AND AS 1112 SNUG TIGHTENED. 8.8/S - HIGH STRENGTH STRUCTURAL BOLTS, NUTS AND HARDENED WASHERS TO AS 1252, SNUG TIGHTENED ONLY. 8.8/TF - HIGH STRENGTH STRUCTURAL BOLTS AS ABOVE, FULLY TENSIONED TO AS 1511 IN FRICTION TYPE JOINT AND UNLESS NOTED OTHERWISE, WITH CONTACT SURFACES LEFT UNCOATED. 8.8/TB - HIGH STRENGTH STRUCTURAL BOLTS AS ABOVE, FULLY TENSIONED IN BEARING TYPE JOINT. 20. CONCRETE ENCASED STEELWORK SHALL BE WRAPPED WITH SL41 MESH, UNLESS OTHERWISE SHOWN. 21. FOR CONCRETE ENCASED STEELWORK, PAINTING SHALL EXTEND 100mm INTO THE CONCRETE. THE REMAINDER OF THE ENCASED STEELWORK SHALL BE UNPAINTED AND FREE OF LOOSE RUST, LOOSE MILLSCALE, DIRT, OIL AND GREASE. 22. BEFORE FABRICATION IS COMMENCED, THE LT SUBCONTRACTOR SHALL SUBMIT A HARD COPY OF THE WORKSHOP DRAWINGS TO THE ENGINEER FOR REVIEW. ALLOW 7 WORKING DAYS FOR REVIEW AFTER SUBMISSION. 23. THE SUBCONTRACTOR SHALL PROVIDE AND LEAVE IN PLACE UNTIL PERMANENT BRACING ELEMENTS ARE CONSTRUCTED, SUCH TEMPORARY BRACING AS IS NECESSARY TO STABILISE THE STRUCTURE DURING ERECTION. 24. THE NUMBER OF PURLINS SHOWN IS INDICATIVE ONLY. IT IS THE LT SUBCONTRACTOR'S RESPONSIBILITY TO ENSURE THE CORRECT NUMBER OF PURLINS ARE USED TO SATISFY SPACING REQUIREMENTS. 25. FIX 100 x 70 x 2.5 COLD FORMED ANGLE PURLINS TO SUPPORT DIAGONAL CUT EDGES OF ROOF SHEETING, UNLESS DETAILED OTHERWISE. 26. ROOF AND/OR WALL SHEETING SHALL BE FIXED TO PURLINS OR GIRTS IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN RECOMMENDATIONS. 27. SLOTTED HOLES: WHERE 8.8/TF BOLTS ARE USED IN SLOTTED HOLES, A SPECIAL WASHER OR COVER PLATE, NOT LESS THAN 8mm THICK, IS TO BE USED TO COMPLETELY COVER THE SLOTTED HOLE.

THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL ARCHITECTURAL AND OTHER CONSULTANTS DRAWINGS AND SPECIFICATIONS AND WITH SUCH OTHER WRITTEN INSTRUCTIONS AS MAY BE ISSUED DURING THE COURSE OF THE CONTRACT. ALL DISCREPANCIES SHALL BE REFERRED TO THE ENGINEER FOR DECISION BEFORE PROCEEDING WITH THE WORK. ALL DIMENSIONS RELEVANT TO SETTING OUT AND OFF-SITE WORK SHALL BE VERIFIED BY THE SUBCONTRACTOR BEFORE FABRICATION AND CONSTRUCTION IS COMMENCED. THE ENGINEER'S DRAWINGS SHALL NOT BE SCALED. DURING CONSTRUCTION THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE STRUCTURE IN A STABLE CONDITION AND ENSURE NO PART IS OVER-STRESSED. WORK METHOD STATEMENTS ARE TO BE PREPARED BY THE SUBCONTRACTOR WITH RESPECT TO ANY DEMOLITION / ERECTION OF STRUCTURAL STEEL / CONCRETE / PRECAST CONCRETE ELEMENTS ETC. AND APPROVED BY A REGISTERED ENGINEER. WHERE EXCAVATION WORK IS TO BE CARRIED OUT ADJACENT TO EXISTING FOOTINGS, THE EXACT LEVEL OF THE UNDERSIDE OF THE FOOTINGS SHALL BE OBTAINED BY TEST PITS PRIOR TO EXCAVATION. UNDERPINNING AND SHORING OF THE STRUCTURE SHALL BE CARRIED OUT AS DETAILED AND THE EXISTING STRUCTURE SHALL BE MAINTAINED IN A STABLE AND UNDAMAGED CONDITION. WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH THE RELEVANT CURRENT AUSTRALIAN STANDARDS (INCLUDING ALL AMENDMENTS) AND THE STATUTORY AUTHORITIES' REQUIREMENTS, EXCEPT WHERE VARIED BY THE CONTRACT DOCUMENTS.

Level 6 HQ South Tower 520 Wickham Street Fortitude Valley QLD 4006 Australia PO Box 1077 Fortitude Valley QLD 4006 T +61 7 3215 4600 F +61 7 3215 4666 www.leightoncontractors.com.au
Architect

2.

2. 2.

9.

BVN Donovan Hill PO Box 801 Fortitude Valley QLD 4006 T +61 7 3852 2525 F +61 7 3852 2544 www.bvn.com.au
Structural/Civil/Mechanical/Electrical/Hydraulic Engineers

3.

3. 27. ALL REINFORCEMENT SHALL BE SECURELY SUPPORTED IN ITS CORRECT POSITION DURING CONCRETING BY APPROVED PLASTIC BAR CHAIRS U.N.O. MINIMUM 25% VOID WITHIN ENCLOSED PERIMETER. MAXIMUM CENTRES OF SUPPORTING CHAIRS SHALL BE 500mm FOR FABRIC, 600mm FOR BARS UP TO 12mm DIAMETER, 800mm FOR BARS 16mm AND GREATER. 28. WHERE NO REINFORCEMENT IS SHOWN ON THE DRAWING AT RIGHT ANGLES TO THE MAIN REINFORCEMENT, PLACE N12-300 TRANSVERSE TO THE REINFORCEMENT SHOWN TO SUIT THE BAR LAYING SEQUENCE. 29. ALL OPENINGS AND RE-ENTRANT CORNERS IN THE CONCRETE SHALL HAVE 2-N12 BARS x 1200 LONG TOP AND BOTTOM CENTRED DIAGONALLY ACROSS THE CORNER. 30. CONSTRUCTION BREAK LOCATIONS AND DETAILS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER PRIOR TO CONSTRUCTION. 31. THE FACE OF ALL CONCRETE WHICH HAS REINFORCEMENT PROJECTING FROM IT AND AGAINST WHICH NEW CONCRETE IS TO BE CAST IS TO BE THOROUGHLY MECHANICALLY SCABBLED, FULLY EXPOSING THE AGGREGATE MATRIX. 32. ALL CONCRETE SURFACES ARE TO BE CURED FOR SEVEN DAYS AFTER CASTING USING A METHOD APPROVED BY THE STRUCTURAL ENGINEER. 33. ALL UN-REINFORCED MASONRY WALLS ARE TO BE SEPARATED FROM ABUTTING CONCRETE WITH TWO LAYERS OF SUPER ALCOR.

OPUS PO Box 99 Spring Hill QLD 4004 T +61 7 3838 2400 F +61 7 3838 2401 www.opus.com.au

3.

4.

ICHTHYS ONSHORE LNG FACILITIES

4.

5.

Darwin Australia

5. 6.

6.

4.

7.

8. 5.

9.

6.

ALL DIMENSIONS ARE IN MILLIMETRES UNLESS STATED OTHERWISE. ALL LEVELS ARE EXPRESSED IN METRES. CONSTRUCTION OF ANY MASONRY WALLS OR OTHER PERMANENT LOADING MUST NOT BE BUILT ON CONCRETE SLABS OR BEAMS UNTIL FORMWORK SUPPORTING SAME HAS BEEN REMOVED. HOWEVER PROPS AND FORMWORK SHALL NOT BE REMOVED BEFORE THE MINIMUM TIME SPECIFIED. DISTRIBUTE MASONRY ON SLAB ADJACENT TO ITS FINAL POSITION PRIOR TO CONSTRUCTING WALLS. ALL NON-LOADBEARING WALLS SHALL BE KEPT CLEAR OF THE UNDERSIDE OF SLABS AND BEAMS BY 20mm UNLESS OTHERWISE SHOWN.

10. MINIMUM COVER TO ALL REINFORCEMENT SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE: -----------------------------------------------------------------------------------FORMED FORMED NOT FORMED ITEM NOT EXPOSED EXPOSED TO CAST AGAINST TO WEATHER GROUND, GROUND ETC. WATER, WEATHER ------------------------------------------------------------------------------------COLUMN 50 50 65 ------------------------------------------------------------------------------------BEAM 40 40 65 ------------------------------------------------------------------------------------FOOTING 50 65 ------------------------------------------------------------------------------------SLAB 25 40 65 ------------------------------------------------------------------------------------WALL 25 40 65 ------------------------------------------------------------------------------------11. PIPES OR CONDUITS SHALL NOT BE PLACED WITHIN THE CONCRETE COVER TO REINFORCEMENT. 12. LAPS IN REINFORCING BARS SHALL BE MADE ONLY IN POSITION SHOWN ON THE STRUCTURAL DRAWINGS OR AS OTHERWISE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER. LAPS SHALL BE IN ACCORDANCE WITH THE FOLLOWING TABLE, UNLESS SHOWN OTHERWISE. LOCATION -----------------------------------------------------------------------------------LAPS IN SLABS AND BAR ALL LAPS UNLESS BEAMS WITH MORE TYPE NOTED OTHERWISE THAN 300mm OF CONCRETE BELOW THE BAR -----------------------------------------------------------------------------------N10 400 500 N12 500 650 N16 750 950 N20 1000 1300 N24 1250 1600 N28 1500 2000 N32 1750 2300 -----------------------------------------------------------------------------------13. UNLESS NOTED OTHERWISE ALL SLABS ON GROUND ARE TO BE CAST ON A 250 MICRON THICK POLYTHENE SHEET, LAPPED AND TAPED AT JOINTS, LAID OVER A 50mm MIN. THICK SAND BED. 14. LAPS IN MESH (FABRIC) SHALL COMPLY WITH AS 3600. THE TWO OUTERMOST TRANSVERSE WIRES OF ONE SHEET SHALL OVERLAP THE TWO OUTERMOST TRANSVERSE WIRES OF THE SHEET BEING LAPPED. 15. SIZES OF CONCRETE ELEMENTS DO NOT INCLUDE THICKNESS OF APPLIED FINISHES. 16. BEAM SIZES ARE SHOWN DEPTH FIRST AND INCLUDE SLAB THICKNESS. 17. UNLESS NOTED OTHERWISE ALL FORMED EDGES AND CORNERS OF CONCRETE MEMBERS SHALL HAVE 20mm CHAMFERS. 18. DRIP GROOVES ARE TO BE PROVIDED AT ALL EXPOSED EDGES. COVER TO REINFORCEMENT TO BE MAINTAINED. 19. EXACT SIZE AND LOCATION OF PENETRATIONS ARE TO BE OBTAINED FROM WORKSHOP DRAWINGS PRIOR TO SCHEDULING OF REINFORCEMENT, AND ARE NOT TO EXCEED DIMENSIONS WHERE SHOWN ON STRUCTURAL DRAWINGS.

Subcontractor ISSUE PURPOSE: CTR RESULT CODE: NEXT STATUS:

FA A FA

FR B FR

FI N FI

FC F FC

AB CA AB NA

7. 8.

Subcontractor RESUB / NEXTSUB DATE:


Approval or review hereunder shall not be construed to relieve Vendor / Subcontractor of his responsibilities and liability under the Contract.

9.

CTR ORGANIZATION PJ DEPT RESPONSIBLE DEPT RELATED DEPT

DEPT NAME

SIGNATURE

CTR REVIEW DATE: JOB NO CPY DOC NO 0-6037-2 REVIEW CLASS

2
REV

SYSTEM NO - CLASS/DISC - TYPE - SERIAL NO

L290-DS-LAD-10055.001
PURCHASER ORDER NO - SERIAL NO

7.

10. WHERE EXCAVATED SURFACES THAT ARE REQUIRED TO SUPPORT FOUNDATIONS BECOME SOFTENED OR LOOSENED DUE TO ADVERSE WEATHER, ALL AFFECTED MATERIAL SHALL BE REMOVED DOWN TO AN ACCEPTABLE BEARING LEVEL AND REPLACED IMMEDIATELY WITH A 10 MPa BLINDING LAYER.

CHEMICAL & MECHANICAL ANCHORS


1. "CHEMSETS" DENOTES RAMSET GRADE 5.8 HOT DIPPED GALV. STUDS FIXED WITH RAMSET CHEMSET REO 502 WITH THE FOLLOWING MINIMUM EMBEDMENTS: M12 CHEMSETS M16 CHEMSETS M20 CHEMSETS M24 CHEMSETS 2. 110mm EMBEDMENT U.N.O. 125mm EMBEDMENT U.N.O. 150mm EMBEDMENT U.N.O. 160mm EMBEDMENT U.N.O.

CTR DOC NO

V-31D1-BLD-1-Z24051

10. ALL BOLTS, NUTS AND WASHERS INCLUDING H.D. BOLTS ARE TO BE HOT DIP GALVANISED. ALL CAST IN FERRULES AND MASONRY ANCHORS TO BE HOT DIP GALVANISED. ALL GALVANISED COMPONENTS TO BE CAST INTO CONCRETE MUST BE PASSIVATED. 11. THE FOLLOWING STEELWORK SHALL BE HOT DIP GALVANISED: PLATE/ANCHOR ROD ASSEMBLIES CAST INTO CONCRETE. ALL MEMBERS BUILT INTO BRICK OR BLOCKWORK. 12. ALL COLD FORMED PURLINS AND GIRTS ARE TO BE MANUFACTURED FROM ROLL-FORMED GALVANISED STEEL COMPLYING WITH AS 1397. STEEL SHALL BE GRADE G450 FOR BASE METAL THICKNESSES 1.5 AND GREATER, GRADE G500 FOR BMT OF 1.2, AND GRADE G550 FOR BMT OF 1.0. - ALL COLD FORMED MEMBERS TO HAVE A MINIMUM COATING MASS OF 350g/sq.m EXCEPT FOR THE FOLLOWING AREAS, WHICH ARE TO HAVE A MINIMUM COATING MASS OF 450g/sq.m: - ALL MEMBERS IN EXTERNAL, EXPOSED ENVIRONMENTS - ALL WALL AND ROOF FRAMING TO DANGEROUS GOODS STORE. 13. ALL STRUCTURAL STEEL FIXING DETAILS ARE TO BE BASED ON A.S.I. STANDARDISED STRUCTURAL CONNECTIONS, UNLESS NOTED OTHERWISE. ALL BOLT HOLES 2mm OVERSIZE U.N.O. HOLES FOR H.D. BOLTS 6mm OVERSIZE U.N.O. OVERSIZE HOLES FOR H.D. BOLTS WILL REQUIRE OVER SIZE WASHERS UNDER NUTS. BOLT HOLES IN STEELWORK CONNECTING TIMBER SHALL PROVIDE A SNUG FIT, I.E. NOT GREATER THAN 0.5mm LARGER THAN BOLT DIAMETER. 14. STIFFENER PLATES WHERE DETAILED ARE TO BE PLACED ON BOTH SIDES OF WEB TO U.B.'S AND U.C.'S. 15. THE ENDS OF ALL TUBULAR MEMBERS ARE TO BE SEALED WITH 6mm THICK PLATES AND CONTINUOUS SEAL WELDS, UNLESS DETAILED OTHERWISE. 16. ALL HOLES IN PLATES AND STEEL MEMBERS SHALL BE DRILLED, EXCEPT FOR PURLIN AND GIRT HOLES WHICH MAY BE PUNCHED. 17. WHERE DETAILS PREVENT THE NORMAL INSTALLATION OF C.F.W.'S, GRIND THE EDGE OF THE MEMBER TO FACILITATE THE INSTALLATION. 18. CLEANING AND PAINTING OF STRUCTURAL STEELWORK ABRASIVE BLAST CLEAN TO CLASS 2 12 MIN PROTECTIVE COATING REQUIREMENTS: - STEELWORK IN INTERNAL, CONDITIONED ENVIRONMENTS: PROVIDE ONE COAT OF INORGANIC ZINC SILICATE PRIMER MIN. DRY FILM THICKNESS 75 MICRONS. - STEELWORK IN INTERNAL, NON-CONDITIONED ENVIRONMENTS: PROVIDE ONE COAT OF INORGANIC ZINC SILICATE PRIMER MIN. DRY FILM THICKNESS 125 MICRONS. - STEELWORK IN EXTERNAL ENVIRONMENTS (OUTSIDE OF BUILDING ENVELOPE): HOT DIP GALVANISED IN ACCORDANCE WITH AS4680. ALL ASPECTS OF THE PREPARATION AND OF THE SYSTEM ARE TO BE CARRIED OUT IN STRICT ACCORDANCE WITH THE MANUFACTURER'S WRITTEN RECOMMENDATIONS. 19. ALL STRUCTURAL STEELWORK BELOW GROUND TO BE ENCASED BY N25 CONCRETE 75mm ALL ROUND, UNLESS NOTED OTHERWISE.

8.

CONCRETE
1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS 3600 AND AS1379. CONCRETE STRENGTH GRADE FOR PARTICULAR ELEMENTS SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE: AREA CONC. STRENGTH (MPa) - STRIP/PAD FOOTING N25 - SLAB ON GROUND - INTERNAL AREAS, N25 SEALED BUILDINGS - SLAB ON GROUND - INTERNAL AREAS, S40 INDUSTRIAL FLOOR AREAS TO BUILDINGS F, A, E AND S - SLAB ON GROUND - EXTERNAL AREA S32 - EXTERNAL ROAD PAVEMENTS AND REFER CIVIL LAY DOWN AREA DWG - ROTOR STORAGE AREA S40 - SUSPENDED SLABS - INTERNAL AREA N32 - SUSPENDED SLABS - BUILDING E S32 - BLOCKWORK CORE FILL N20 - CONCRETE WALLS S40 NOTE: CONCRETE NOTED AS SPECIAL CLASS TO CONFORM TO AS1379 REQUIREMENTS FOR B2 EXPOSURE PREFIX SB. 3. MAX. AGGREGATE SIZE = 20mm SLUMP = 80mm +/- 15mm (AT POINT OF DISCHARGE) NO 'BRECCIA' TYPE AGGREGATE IS TO BE USED. THE CONTRACTOR IS TO NOTIFY THE STRUCTURAL ENGINEER IN WRITING OF ANY ADMIXTURES TO BE USED IN THE CONCRETE MIX. NO ADMIXTURES SHALL BE USED WITHOUT WRITTEN APPROVAL BY THE STRUCTURAL ENGINEER. CALCIUM CHLORIDE WILL NOT BE PERMITTED AND SHALL NOT BE USED UNDER ANY CIRCUMSTANCES. CONCRETE TESTING - REFER CONCRETE SPECIFICATION ALL FORMWORK SHALL CONFORM TO AS 3610. RESHORING IS NOT PERMITTED.

9.

THE STRUCTURAL WORK SHOWN ON THESE DRAWINGS HAS BEEN DESIGNED FOR THE LIVE LOADS AS NOMINATED IN THE STRUCTURAL ENGINEERING DESIGN REPORT. SPECIFIC DESIGN LIVE LOADS ON SUSPENDED STRUCTURE AS FOLLOWS: AREA ROOF - CCB ROOF - ALL OTHER BUILDINGS WAREHOUSE MEZZANINE LEVEL SUSPENDED CONCRETE CEILINGS LIVE LOAD (kPa) 1.8 0.25 9.6 5.0

2.

"CHEMSET MAXIMA CAPSULES" DENOTES RAMSET CHEMSET MAXIMA SPIN CAPSULES WITH STUDS AND EMBEDMENTS AS DEFINED IN NOTE 1. "TRUBOLTS" DENOTES RAMSET TRUBOLT HOT DIPPED GALV. STUD ANCHORS WITH THE FOLLOWING MINIMUM EMBEDMENTS: M12 TRUBOLTS M16 TRUBOLTS M20 TRUBOLTS 80mm EMBEDMENT U.N.O. 110mm EMBEDMENT U.N.O. 135mm EMBEDMENT U.N.O.

3.

10. IMPORTANCE LEVEL HAS BEEN DETERMINED FOR EACH BUILDING IN ACCORDANCE WITH BCA TABLE B1.2 AND ARE AS FOLLOWS: BUILDING CENTRAL CONTROL BLG IMPORTANCE LEVEL 4 (1:10000 RETURN PERIOD FOR WINDLOADING) 4 (1:2000 RETURN PERIOD FOR WINDLOADING) 2 (1:500 RETURN PERIOD FOR WINDLOADING)

4.

"CHEMSET 101 ANCHORS" DENOTES RAMSET GRADE 5.8 HOT DIPPED GALV. STUDS, FIXED WITH AN EFFECTIVE DEPTH OF 64mm INTO EXTRUDED BRICK OR HOLLOW CONCRETE BLOCK, USING THE MANUFACTURER'S SLEEVES/SIEVES AND RAMSET CHEMSET INJECTION 101. ALL ANCHORS ARE TO BE FIXED IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN RECOMMENDATIONS.

5.

FIRE STATION, RADIO CONTROL BLG ALL OTHER BUILDINGS

BACKFILL TO RETAINING WALLS


1. RETAINING WALLS SHALL BE BACKFILLED AS FOLLOWS: CBR 15 MAX P.I. = 12. FILL SHALL BE PLACED IN 200mm MAX. (LOOSE) LAYERS AND COMPACTED TO 100% STANDARD IN ACCORDANCE WITH AS 1289, TEST E2.1. TESTING OF BACKFILL: ONE FIELD DENSITY TEST PER 400 m. (OR PART THEREOF) EVERY FOURTH LAYER TO AS 1289, TEST E2.1 BY A N.A.T.A. REGISTERED LABORATORY. RETAINING WALLS SHALL NOT BE BACKFILLED UNTIL A MINIMUM 14 DAYS AFTER CASTING. UNLESS NOTED OTHERWISE ON THE DRAWINGS, WALLS WITH THEIR UPPER EDGE RESTRAINED BY FLOOR SLABS, SHALL NOT BE BACKFILLED UNTIL THE SLAB OVER HAS BEEN CAST A MINIMUM 7 DAYS AND THE WALL HAS BEEN CAST A MINIMUM 14 DAYS. PROVIDE 100mm DIA. AGRICULTURAL DRAINS BEHIND ALL RETAINING WALLS AND AS INDICATED ON DETAILS WITH ADEQUATE FALL TO OUTLET. DRAINS SHALL BE BEDDED IN 20mm GRAVEL, MINIMUM 150 COVER. PROVIDE 50mm DIA. WEEPHOLES AT 1200mm MAX. CENTRES WHERE INDICATED ON RETAINING WALL DETAILS.

11. WIND LOADING HAS BEEN DETERMINED IN ACCORDANCE WITH AS/NZS 1170.2 WIND ACTIONS, USING THE FOLLOWING VALUES:

4.

WIND REGION C TERRAIN CATEGORY 2.0 SHIELDING MULTIPLIER 1.0 TOPOGRAPHIC MULTIPLIER 1.0 INTERNAL PRESSURE COEFFICIENT Cp,i +0.7, -0.65 REGIONAL WIND SPEED, VR 1:10000 - 85m/sec 1:2000 - 76.7m/sec 1:500 - 69.3m/sec

2.

3.

5. 6.

AA NO

11-APRIL-13 TENDER ISSUE DATE

ISSUE PURPOSE

SWS CKD

DDG APP

REVISIONS

12. EARTHQUAKE LOADING HAS BEEN DETERMINED IN ACCORDANCE WITH AS/NZS 1170.4 USING THE FOLLOWING VALUES: SOIL CLASS HAZARD FACTOR (z) PROBABILITY FACTOR (kp) Ce 0.09 I.L. 4 - 1.5 I.L. 2 - 1.0 EARTHQUAKE DESIGN CATEGORY (EDC) II

7.

THE LT SUBCONTRACTOR IS RESPONSIBLE FOR THE DESIGN 20. DO NOT CUT REINFORCEMENT ON SITE TO CLEAR AND CONSTRUCTION OF ALL CONCRETE FORMWORK. PENETRATIONS. DISPLACE REINFORCEMENT SLIGHTLY AS WHEN REQUESTED SUBMIT THE FOLLOWING NECESSARY. DOCUMENTATION: FORMWORK DRAWINGS, IN ACCORDANCE WITH CLAUSE 4.7 OF AS 3610. CERTIFICATION BY A QUALIFIED STRUCTURAL ENGINEER EXPERIENCED IN FORMWORK DESIGN VERIFYING THAT THE DESIGN CONFORMS WITH RELEVANT REQUIREMENTS. CERTIFICATION BY A QUALIFIED STRUCTURAL ENGINEER EXPERIENCED IN FORMWORK DESIGN AND CONSTRUCTION VERIFYING THAT THE COMPLETED FORMWORK IS STRUCTURALLY ADEQUATE FOR ITS INTENDED PURPOSE. 21. NO CHASES, HOLES GREATER THAN 150mm DIAMETER, OR EMBEDMENT OF PIPES GREATER THAN 40mm DIAMETER OTHER THAN THOSE SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE MADE IN THE CONCRETE SLABS. FOR ALL OTHER CONCRETE MEMBERS NO PENETRATION, CHASES OR EMBEDMENTS SHALL BE MADE WITHOUT PRIOR APPROVAL BY THE STRUCTURAL ENGINEER. 22. CONDUITS CAST INTO CONCRETE MEMBERS SHALL BE SPACED AT MAXIMUM DISTANCE POSSIBLE AND UNDER NO CIRCUMSTANCES CLOSER THAN A CLEAR SPACING OF TWICE THE LARGER CONDUIT DIAMETER FROM PARALLEL REINFORCEMENT OR ANY OTHER CONDUIT. 23. REINFORCEMENT IS SHOWN DIAGRAMMATICALLY AND NOT NECESSARILY IN TRUE PROJECTION.

4.

ICHTHYS ONSHORE LNG FACILITIES


DRAWING TITLE

5.

STRUCTURAL GENERAL NOTES - EPC BUILDING WORKS - SHEET 1

SCALE COMPANY CONTRACT NO

1 : 100 2
LEICON REV

REVIEW CLASS

JGC JOB CODE

KBR JOB CODE

CHD JOB CODE

LEIGHTON DWG NO

Q1447-V-31D1-BLD-1-Z24051
JKC DWG NO

AA
SIZE

V-31D1-BLD-1-Z24051
COMPANY DWG NO

A1
COY REV

L290-DS-LAD-10055.001 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16