Multi Series

Inverter Multi-Split System Air Conditioners

MHIAA is proudly sponsoring Monikas Doggie Rescue

Multi Series
Inverter Multi-Split System Air Conditioners.

The ideal solution for air conditioning multiple rooms


MULTI series Air Conditioners 2013

WELCOME

A home typically has many areas such as bedrooms, living spaces and study rooms. Therefore, to provide total comfort for your home, a multi-split system is recommended so each room can have its own air conditioner. This can be achieved through a Mitsubishi Heavy Industries inverter multi-split system which delivers optimum heating or cooling for everyone, no matter where they are in the home and no matter what size the room may be. Silent, powerful, energy ef cient and utilising advanced technologies, a Mitsubishi Heavy Industries inverter multisplit system is the solution for homes with many rooms and occupants.

Compact
A Mitsubishi Heavy Industries inverter multi-split system allows 2 to 6 indoor units to be connected to a single outdoor unit. This allows multiple rooms to be conditioned without adding clutter to the exterior of your home. One compact multi-split outdoor unit instead of many outdoor units not only adds to the ascetic appeal your home but can be imperative when there is not much space available, for example, when installing outdoor units on balconies or verandahs.

Installation Flexibility
With a generous maximum piping length of 70m*, you are given greater freedom to decide where the indoor units will be installed to optimise interior space and convenience. In addition, a maximum height difference of 25m* for the indoor units means the Mitsubishi Heavy Industries inverter multi-split system can easily service the rooms for multi storey homes.

Variety of Indoor Units


The indoor unit range includes wall mounted, oor standing, low static bulkhead or compact cassette types in a wide range of capacities. This makes hundreds of combinations possible for your home. You can choose the right type of indoor unit to complement the interior dcor and match the size of each room.
*Please check model specications as these pipe lengths and height differences do not apply to all models.

MULTI series Air Conditioners 2013

MULTI CONCEPT

Independent Control and Comfort


Each indoor unit comes with its own remote allowing the unit to be independently switched on/off and have the temperature adjusted as needed. The conditions of rooms can vary greatly depending on many variables such as the number of occupants or the way the room is used. With a range of comfort, air ow and convenience functions on each indoor unit, you can adjust the settings to match the requirements of a room without affecting other ones. When a room is unoccupied you can switch off the unit to reduce inefcient energy use.

5 Year Warranty
When you buy a Mitsubishi Heavy Industries inverter multi-split system, you are getting an air conditioning solution from a company that some of the highest quality products in the industry. Mitsubishi Heavy Industries enjoys a reputation for outstanding quality and is highly respected both in the Australian and overseas markets. With our 5 Year Warranty covering the parts, labour and compressor, you can peace of mind that your new Mitsubishi Heavy Industries inverter multi-split system will continue to deliver air-conditioning comfort to your home through the years.

Easy operation
All settings done by tapping touch screen panel
Operation mode setting screen

Setting temperature screen The operation mode can be selected by simply tapping this button.

Operation mode
Cooling Dry Auto Fan Heating

You can select the desired temperature by tapping the button.

Main functions
Energy management
Peak cut timer Automatic temperature set back Weekly timer Set ON/OFF timer by hour Set ON/OFF timer by clock Fan only operation Sleep timer

Comfort
Individual ap control High power operation External ventilation ON/OFF Warm up operation Automatic fan speed Temperature increment setting by 0.5C

Convenience
LCD contrast setting Back light setting Filter clean sign Control sound Outdoor silent mode Summer time setting Home leave mode Indoor & outdoor temperature display Heating standby display Defrosting operation display Auto cooling/heating display C/F display Administrator settings Room name setting

Service
Error code display Operation data display Next service data display Contact company display USB connection (mini-B)
MULTI series Air Conditioners 2013

Functions.
Filter

Allergen

Allergen Clear Filter


The lter breaks down the pollen, lice, and all allergens that live on cat skins, etc. and deactivates them.

Filter
SUN

Enzyme

Natural Enzyme Filter


Enzymes used in the lter are naturally occurring lytic enzymes which attack cell walls of microorganisms trapped on the lter and destroy them. See details on page 2.

Filter

CONTROL & FUNCTIONS

Photocatalytic Washable Deodorizing Filter


It keeps air fresh by deodorizing the molecules causing odor. The deodorizing ability can be easily restored simply by cleaning and exposing the lter to the sunlight.

Filter

System Operation
"HI POWER" Operation
The unit can operate continuously in HI POWER mode for 15 minutes. This mode is used to reach the desired temperature quickly.
t Sp ar

Allergen Self Clean

Comfortable Functions Fuzzy Auto Mode


Automatically the unit determines its operating mode and temperature setting based on a fuzzy calculation and adjusts the inverter frequency.

Automatic Operation
The air conditioner automatically selects from heating, cooling or dry operation.

St

3HOT
Keep

Three "Hot" System


Hot start enables the unit to begin heating operation quickly. Hot spurt is a fast heating system that works to increase the temperature setting by two degrees. Hot keep is used during the automatic defrost cycle to prevent cool air being circulated. These three operational control systems help ensure comfortable and efficient heating.

t ur

Comfortable Air Flow Functions 3D Auto


Auto
You can choose the best heating or cooling pattern with the touch of a button.

Memory Memory Flap


While the flap is swinging it can be stopped at any angle. The flap returns to this position next time the unit starts.

Auto Flap Auto Flap Mode


The unit automatically selects the optimal angle whatever the operation mode.

COOLING & DRY Horizontal blowing HEATING Slant forward blowing

UP/DOWN Up/Down Flap Swing

SWING FLAP Flap moves up and The Up/Down flap can be adjusted down to the preferred angle anywhere between horizontal and perpendicular. continuously.

Lateral
Swing

Lateral Swing
The louver swings from right to left automatically. Louver angle can be fixed in any desired position.

Air Scroll Air Scroll


The swing of the flap causes the air flow to spiral and the breeze to reach all corners of the room.

COOLING & DRY Thick line : moves quickly Thin line : moves slowly HEATING Thick line Thin line : moves quickly : moves slowly

Air outlet Air Outlet Selection selection Both lower and upper air outlets and upper air outlet can be
selected. (SRF models only)

Positioning of installation

Positioning of Installation
You can set the left-right air ow directions when you install the air conditioner near the side wall by remote controller operation.

Convenience & Economy Functions


On Timer On Timer
This enables the operation to start a little earlier so that the room is near to the set temperature at ON time.

24-hour On/Off Programmable Timer


24h Timer
By combining a start timer with a stop timer you can register two timer operations a day. Once set timers will start or stop the system at the specified time of the day repeatedly.

Economy Economy Mode


The unit achieves effective energy saving operation while still keeping a comfortable cooling or heating operation.

OFF Timer Off Timer


The unit stops at the specified time.

Dry Operation
DRY
The unit dehumidifies the room by intermittent cooling operation.

Sleep

Sleep Mode
The room temperature is automatically controlled during the set sleep mode period ensuring that the room temperature will not get too hot or cold.

Maintenance & Prevention Functions

MC

Microcomputer-Operated Defrosting
This function automatically eliminates frost and helps minimize excessive operation in other modes.

Detachable Detachable Indoor Air Inlet Panel

The air inlet panel on the indoor unit opens and closes easily making filter cleaning simple. The suction panel can be easily removed. When removing the air inlet panel for internal cleaning or other reasons, open the grill by 65 degrees and then pull it to the side.

Self-Diagnostic Function Self Diagnostic If the air conditioner malfunctions an internal microcomputer runs a
self diagnosis. Inspection and repair should be performed by authorized dealers.

Others
Back-up Back-up Switch Switch On the indoor unit there is a back up on/off switch. The system will
operate in the previous mode.

24-hour ION
24h ION
The air conditioner body has a tourmaline coated sheet. Negative ions (2,500 -3,000/cc) are generated when the air conditioner is not running, allowing you to experience them without incurring any electrical cost.

Auto Auto Restart Function Restart Power blackout auto restart function records the operational status of
the air conditioner immediately prior to being switched off by a power supply interruption. The unit automatically resumes operations in the mode and temperature set point after the power has been restored.

Luminous

Luminous Button
With wireless Luminous remote controls that even glow in the dark, it is possible to operate all desired functions of the unit with the click of a button.

High Ef ciency.
DC PAM inverter
An inverter system has a number of advantages over a constant speed system. Its variable speed compressor outputs can ensure quick cooling or heating after start up and attains a set temperature more quickly. The air conditioner can slow down the compressor speed to save energy whilst keeping comfortable conditions. The compressor is DC motor driven so it provides superior performance.

New inverter control (Vector control)


New Inverter Control has applied the new advanced technology of Vector control enabling: Smooth operation from low to high speed Smooth Sine Voltage Wave form is achieved Energy efficiency has improved in low speed range
Time Time

DC PowerActiveModule P AM INVERTER

DC compressor motor
Magnet Motor Motor Efficiency(%)

DC PAM INVERTER

Room Temp.

CONVENTIONAL INVERTER
PWM

Room Temp.

PAM

Improving Improving
Induction Motor

Set Temp. Even Temperature

Set Temp.

DC PAM INVERTER

Rated Capacity ON Compressor (rps)

CONVENTIONAL

ON

OFF

Rated Capacity OFF

Compressor (rps)

Low

Revolution speed

High

Utmost comfort and energy efficiency achieved with large output power and control optimisation

Less advanced technology does not address the ON/OFF cycle issue.

Advanced Technology.
Silicon-coated PCB
The printed circuit board of the outdoor unit is coated by silicon. The coating ensures longevity of the board in humid conditions.

Propeller fan
The new propeller fan was carefully matched with a fan motor in order to keep the same capacity as that of previous models with less electrical consumption.

Superior corrosion resistance


The base of the outdoor unit is hot dipped to provide superior corrosion and scratch resistance.

Outdoor unit
Redesigned by changing the n con guration from at sheet to new M shape n, ef ciency has been improved. An optimum balance of heat transfer and air ow has been achieved.

MULTI series Air Conditioners 2013

-15C

Cooling
0 10 20 30 40

+46C

-20

-10

50

Advanced Technology.
Anti-microbial indoor fan

For the capacities under low temperature conditions, refer to technical manual.

Applied models
All SRK

on w Comparis
70dB

ith familiar

noises in

our everyd

ay life

n Compariso
70dB

with fam

eryday s in our ev 60dB iliar noise

nv Normal co

ersations
life

21dB
t in a Late nigh rban area bu typical su

Quiet of

ce

Normal Anti-microbial specifications and design will deliver cleanliness and safety
60dB 50dB 40dB 30dB 20dB 10dB 0dB

conv

dB tions 50 sa er 40dB 30dB 20dB

rary In the lib 21dB

Quiet of

ce In the lib

60dB

a rary Late night in ea burban ar typical su

FEATURES

50dB
30dB

40dB

10dB 60dB 50dB 0dB

30dB

21dB

40dB

21dB
SRK20ZJX-S

SRK20ZJX-S
(In the Cooling Lo mode)

(In the Cooling Lo mode)

Applied models
SRK-ZJX, SRK-ZK, SRK-ZJ, SRF-ZJX

-15C

Heating

+21C

-15C

Cooling
0 10 20 30 40

+46C

-20

-10

50

For the capacities under low temperature conditions, refer to technical manual.

Anti-microbial treatment
The indoor fan has undergone anti-microbial treatment to resist growth of mould and germs. Mould creating odours Applied models which can occur when an air conditioner is not in operation All SRK, SRF are prevented.
Co

All SRK, SRF, SRR, FDTC

All SCM-appearance may vary

SRK50/60ZJX, SRK-ZK, SRK35/50ZJ, SRK-ZJX

All SRK, SRF, SRR, FDTC

All SCM-appearance may vary

SRK50/60ZJX, SRK35/50ZJ, SRK-ZJX Comparison of growth of bacteria and SRK-ZK, mold on fan surfaces ay life our everyd r noises in (microscopic mp image) th familia 21dB arison wi
70dB

Washable filter and easy cleaning of the air inlet panel


Applied models
All SRK, SRF

Normal co

nversatio

ns

60dB 50dB 40dB

Quiet of

ce In the lib

a rary Late night in ea burban ar typical su

Removing the air lter is quite easy. Keeping the air lter clean is an effective way to save energy and keep the original powerful performance of your unit. The air inlet panel is models also removable and can be cleaned easily. Applied
SRK50/60ZJX, SRK-ZK SRF-50ZJX

without 30dB with without with Anti-microbial Anti-microbial Anti-microbial Anti-microbial 60dB 50dB 0dB 21dB 40dB
20dB

10dB 0dB

SRK20ZJX-S
(In the Cooling Lo mode)

Maximum pipe length

Three sensors
Control of room temperature and humidity is very important for Applied models people to live a comfortable life. Use of three sensors to control SRK50/60ZJX, SRK-ZK indoor temperature, indoor humidity and outdoor temperature SRF-50ZJX enable the unit to obtain optimum air-conditioning.
Applied models

30m 20m

Aspergillus niger IFO 6341

Maximum height difference

Escherichia coli IFO 3972

In tests conducted at the Mitsubishi Heavy Industries Nagoya Research Lab, 24 hrs after contact with bacteria, cultured on agar media.

Maximum pipe length

30m 20m

Live Bacteria Count on Measured Test Pieces

SRK-ZJX, SRK-ZK, SRK-ZJ, SRF-ZJX

-15C +21C <10 <10 <10 Test piece 1 After 24 hrs Heating SRK-ZJX, SRK-ZK, IFO 3972 colicooling SRK-ZJ, SRF-ZJX 3.8 x 106 4.9 x 106 7.2 x 106 Heating and operations are possible Not treated at 35C Comparison of growth of bacteria and mold on fan surfaces
Applied models
All SRK, SRF

Immediately after contact Wide operation range Escherichia coli


Applied models

Tested Contaminant

Measurement

Test Pieces
Not treated

+21C Heating Bacteria Count Per Test Piece SRK50/60ZJX, SRK-ZK, SRK35/50ZJ, SRK-ZJX Measurement 1 Measurement 2 Measurement 3 5 1.6 x 105 1.9 x 105 -15C Cooling 1.3 x 10+46C

-15C

All SRK, SRF, SRR, FDTC

Maximum height difference

All SCM-appearance may vary

at an outdoor temperature as low as 15C Immediately after contact Not treated (microscopic 1.4 x 105 Forimage) 105 the capacities under1.6 low x temperature conditions,
Our advanced technology has improved and Test piece 1 cooling <10 After 24 hrs the heating aureus Not treated operation range. Units can be installed or cooling 8.6 x 105 at 35C when heating operation is required at low ambient conditions down to -15C. 1.5 x 104 Not treated Immediately after contact

-20

-10

10

20

30

Staphylococcus

refer to technical -15 C manual.

4.5 x 105
-20 -10
For the capacities under low temperature conditions, refer to technical manual.

<10

Cooling
20

1.3 x 105

40

50

<10 3.6 x 105


301.6 x 1040 4

+46C

Quiet operation
Applied models
SRK50/60ZJX, SRF-50ZJX

Aspergillus niger

0 x 104 10 2.2

50

After 24 hrs at 35C

Test piece 1 Not treated

<10 1.0 x 104


70dB

<10 1.2 x 104


ns

Test Pieces 1) Products with Antimicrobial and Antifungal Treatment

Silent airflow and long reach SRK-ZK

on Comparis

with fam

iliar noise

s in our ev

eryday lif

<10 2.5 x 104

Normal co

nversatio Maximum pipe length

21dB

The secret of quiet operation


The combination of the jet air ow system and serration stabilizer con guration ensures uniform breeze to every corner of the room. It also makes it possible to lower the operation noise further by minimizing the interaction between air ow and the fan.

60dB 50dB 40dB

ce Quiet of 30m

Maximum height difference


on with fa

In the lib

Comparis
30dB 70dB 20dB 60dB 10dB 50dB 0dB

ises in ou miliar no 20m

a rary Late night in ea burban ar typical su e lif r everyday

nv Normal co

60dB

ersations

21dB
21dB

Quiet of

50dBce 40dB
In the lib

a rary Late night in ea burban ar typical su


SRK20ZJX-S
(In the Cooling Lo mode)

30dB

40dB 30dB 20dB 10dB 0dB

60dB

50dB

40dB

30dB

21dB
SRK20ZJX-S

(In the Cooling Lo mode)

10

3D AUTO Vertical + Horizontal AIR SCROLL.


3 motors make 3 independent controls

3 motors make 3 independent controls

3 motors make 3 independent controls 3 motors make 3 independent controls

Programmedairdistribution

Programmedairdistribution
Applied models

3D AUTO 3D AUTO

Applied mode

SRK-ZJX, SRK-ZJ

3D AUTO is a one touch programme. Three motors (one vertical working motor + two horizontal working motors) make three independent air ow controls. The air ow is uniform, quiet and reaches at long distance from the indoor unit.
SRK63/71/80ZK, Manual Setting only

SRK-ZJX, SRK

SRK63/71/80Z Manual Setting

Programmedairdistribution Programmedairdistribution

Programmed 3D AUTO
3Dair AUTO Automatic control of ow volume and air 3D AUTO Swing
Hi-Power (Quick)
Cool Shower Floor Heating

Manual Setting
Vertical Swing Individual control

Applied mode Applied model

ow direction of right and left louver enables air 1 enables comfortable air conditioning of the entire room. ow direction from the right and the left side of the In cooling operation, cooled air ows directly to the ceiling unit, setting the most preferable air ow direction and Cool Shower Floor Heating Hi-Power (Quick) Widedirectly Swing (Every Corner) not onto the occupants of the room. The comfort determining whether direct air ow is required or not. Vertical Swing cooled air ow comes down from the ceiling like a soft Swing Swing 2 shower. 1 In heating operation, warm air ows to the oor directly Center (Long) along the oor. The concentrationHorizontal and spreads of the Air Scroll 8 Direction Swing 1 2 3 4 Wide Swing (Every warm air at oor Corner) level increases comfort. Swing
3
Swing

SRK-ZJX, SRKSRK-ZJX, SRK-Z SRK63/71/80ZK SRK63/71/80ZK Manual Setting o Manual Setting o

Hi-Power (Quick) Hi-Power (Quick)

2 Wide-Air (Equal)
4

Swing

Cool Shower Cool Shower


Swing Swing
Floor

Floor Heating 7 Floor Heating 8


Spot 1

6
Wide

5
VerticalSwing Swing Vertical

Cool Shower

Center (Long)

1 1

Horizontal Air Scroll 8 Direction Swing


Swing

Wide Swing (Every Corner) Wide Swing (Every Corner)

Swing Swing

2
Swing Swing

Wide-Air (Equal)

2 2

8
Cool Shower Floor
Swing Swing Swing Swing

7
22

6
3 3
Wide

5
4 4

Center (Long) Center (Long)

3 3
Wide-Air (Equal) Wide-Air (Equal)

11 Swing

Horizontal Air Scroll88Direction DirectionSwing Swing Horizontal Air Scroll


Spot

Cool Shower Cool Shower Floor Floor

88
Swing Swing

77
Spot Spot

6 6
Wide Wide

5 5

MULTI series Air Conditioners 2013

Jet air scroll long reach & silent air ow.


FEATURES

Aircraft technology was used in the design of the air conditioners airflow system

Fast

Slow

Colors in the gure show the air speed.

We used the same aerodynamic analysis technology as used in developing jet engines.
CFD (computational uid dynamics) is used for blade shape design and air channels for jet engines. The same technology has been used in our air conditioners. The air ow of the jets created in this system enables a large volume of air to be blown with a minimum amount of power consumption. The air ow is uniform, quiet and reaches a long distance from the indoor unit.
SRK50/60ZJX SRK71ZK
(in cooling operation) (in cooling operation)

Long Reach Air Flow


The jet technology enables powerful air ow ideal for large living areas and commercial premises, increasing your comfort.

15m

17m

powerful

Positioning of Installation
You can set the left-right air ow directions when you install the air conditioner near the side wall by remote controller operation.

New louver
The new louver has a new design and shape.It has increased in surface area by 80%. In addition to improved control of the increased air ow volume, it has improved controllability of the right to left swing function.
80% increased

80% increased

previous

New

previous

New

11

12

Clean Air.
Allergen Clear System
The Allergen Clear system suppresses the in uence of the allergen caught by the lter by controlling the temperature and humidity.

Catching Allergen on the Filter

Cooling Operation
To make condensing water.

Heating Operation
To give moisture to the Filter to inactivate allergen

AIR Purify

Self-Clean Operation
To dry up the indoor unit

Stop run Stop run


Stop run

2hrs 2hrs
2hrs

Normal Normal operation Normal operation

operation

Clean Clean operation Clean operation

operation

Shuts off automatically Shuts off automatically

After one week


First in the world
Generates the same amount of negative ions as a forest environment

Shuts off automatically

without self clean opration


mycelia Fungal Fungal mycelia mycelia Fungal

20 of Patent Pending

24-hour ION

The air in your room is kept fresh

Allergen clear system The air conditioner body has a The Allergen Clear system tourmaline coated sheet. Negative ions suppresses the in uence of the (2,500 -3,000/cc) are generated even Situation of mold allergen when the air conditioner is not running, Situation of caught mold by the lter by after week Situation ofone mold controlling the temperature and allowing you to experience them after one week humidity. after without incurring any electrical cost. one week

After one week


with self clean opration
Spore of mold Spore

Spore Spore mold ofof mold

Spore of mold

of mold Spore of mold

Situation ofof mold after one week Situation mold after one week
When dontafter execute Self Clean Operation Situation ofyou mold one week

When you dont execute Self Clean Operation

When you execute Self Clean Operation When you execute Self Clean Operation The of When you execute Self Clean Operation Thespore spore ofmold mold doesn't doesn'tgerminate. germinate.

Fungal mycelia When you dont execute Self Clean Operation Fungal mycelia expand. expand.

Fungal mycelia expand.

The spore of mold doesn't germinate.

Self Clean Operation


The self clean operation is operated for 2 hours after the unit has ceased normal operation. The indoor fan continues to operate on ultra low speed to dry the unit. This restricts the growth of mould. This feature can be selected on the remote control.
MULTI series Air Conditioners 2013

Rate of inactivation against allergens collected on the lter


H2N-

Urea

A molecule is decomposed
Enzyme
Reduction in a molecule 99.9%

Slack of high order structure

100

-COOH

93.6% 72.7%

99.0%

Protein structure of allergen Sterilization Mechanism

Inactivation rate(%) Inactivation rate(%)

83.5%

83.5%

Allergen clear lter


Enzyme + Urea deactivates allergens and kills bacteria

-COOH Sterilization Mechanism This is the original and only technology to control the temperature and for inactivating allergens 93.6% 100 humidity

H2N-

Sterilization Mechanism Enzyme 50 Urea Rate of inactivation against allergens collected on the lter
Slack of high order structure

A molecule is decomposed
99.9% 99.0%

Slack of high order structure Protein structure Urea of allergen

Sterilization Mechanism 83.5%


H2N-

Urea

Reduction in a molecule

Enzyme
83.5%
*2

H2N-

Inactivation rate(%)

LISA colorimetric method Test method: Independent administrative aboratory: ue 50%) ELISA colorimetric method agency national hospital dependent administrative Laboratory: mechanism Sagamihara gency national hospital azato Independent administrative Hospital, No.1536 mechanism Sagamihara agency national hospital ence Center, Test method: ospital, No.1536 mechanism Sagamihara ELISA colorimetric method est method: Hospital, No.1536 Laboratory: CID (Infection value 50%) Test method: administrative Independent aboratory: TCID (Infection 50%) agency nationalvalue hospital oundation ofSagamihara Kitazato Laboratory: mechanism nvironmental Science Center, Foundation of Kitazato Hospital, No.1536 o.15-0145 Environmental Test method: Science Center,

6 est method: Hospital, No.1536 Laboratory:

Inactivation rate(%) Inactivation Inactivation rate(%)rate(%)

Rate of inactivation against allergens collected on the lter


*1 *1 *2 *2 *3 *3

Inactivation rate(%)

The allergen clear lter deactivates pollen lice and allergens that live on cat skin etc. The deactivation secret is the Enzyme-urea compound. It deactivates not only allergens LISA colorimetric method / Test method: LISA method ELISA uorescent colorimetric method / but some bacteria, moulds and viruses. Even if allergen, c method aboratory: ELISA uorescent method dependent administrative Laboratory: mould, virus or bacteria y off the lter they are deactivated nistrative gency national hospital Independent Test method: administrative ospital mechanism Sagamihara agency national hospital ELISA colorimetric method / so the air in your room is kept fresh. mihara ospital, uorescent No.1536 mechanism Sagamihara ELISA method

c method / method

Rate of inactivation against on the lter Protein structure of allergens allergen collected Urea Enzyme 50
-COOH Slack of high order structure -COOH

A molecule decomposed House dust mite A species of mite Cedar pollen is Epithelium of cat Sterilization Mechanism Slack of high order structure Reduction in a molecule
H2N-

Urea -COOH
*1

Enzyme 72.7% Reduction in a molecule Enzyme


*2

*1

Virus i
*3

Virus p
*3

FEATURES

Reduction in a molecule

nistrative ospital mihara est method: 6

of allergen 93.6% 100 H2N-Protein structure Slack of high order Protein structure of structure allergen 83.5% -COOH 72.7%
100 100

99.9%

Rate of inactivation against allergens collected Rate of inactivation against allergens collected on the 99.9% lter on the lter Protein structure of allergen 99.0% Rate of inactivation against allergens collected the lter 99.9% on99.0% 0 100 50 93.6% 93.6%
A molecule is decomposed A molecule is decomposed 99.0% House dust mite A species of mite 83.5% Cedar pollen99.9% Epithelium of cat Virus i 93.6% 83.5% 83.5% 83.5% *1 *1 *2 *2 *3 83.5% 72.7% 83.5% 72.7% 72.7% 99.9% 99.0% 93.6% 100 50 83.5% 83.5% 5050 House dust mite A species of mite Cedar pollen Epithelium of cat Virus i Virus p 72.7%
50 0 0 House dust mite A species of mite

in a molecule 83.5% AReduction molecule is decomposed

A molecule is decomposed

99.0%

Virus p
*3

*1 *1 of mite House dust mite A species *1 *1

Cedar pollen Epithelium of cat *2 pollen Epithelium *2 of cat Cedar


*2

First in the world


Cedar pollen
*2 *2

Virus i *3 i Virus
*3

Virus p *3 p Virus
*3

No.15-0145 TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145

*1 *1 0 Conventional Filter *2 House dust mite A species of mite Cedar pollen Epithelium of cat
*1 *1 *2

House dust mite A species of mite

Epithelium of cat
*2
*3

*3 Filter*3 Enzyme Virus i Virus p


*3

Virus i

Virus p

Natural enzyme lter


(Cat hair, dust mite, pollen etc.)

First in Filter the world Helps to destroy fungi and bacteria, also effective on viruses and allergenic compounds Conventional
Conventional Filter

Analysis Zone

First in the world


Enzyme Filter

Air ow

Analysis Zone

Bacterium Conventional Filter


Analysis Zone Enzyme Analysis Zone

Airow ow Air ow Air

The enzymes used in these lters are naturally occurring lytic enzymes. Lytic enzymes attack cell walls of microorganisms trapped on the lter and destroy them. The Natural Enzyme Filter will clean and sanitize air passing through it.

Filter First inEnzyme the world


Analysis Zone Analysis Zone

Air ow

Air ow

Enzyme lter

First Firstin inthe theworld world Conventional Filter Enzyme Filter Enzyme's sterilizing mechanism Conventional Filter Enzyme Filter Analysis Zone Analysis Zone FirstZone in the world Analysis Analysis Zone
Enzyme

Enzyme Filter

Enzyme's sterilizing mechanism

Conventional Filter

Enzyme Filter
Powerful sterilizing effect

Filter ber Analysis Zone Bacterium


Bacterium

Air ow

Coupling Enzyme's Bacterium sterilizing mechanism Cell wall mechanism Enzyme Enzyme's sterilizing Enzyme
Bacterium Enzyme's sterilizing mechanism Enzyme Enzyme

Analysis Zone Analysis Zone Enzyme's sterilizing mechanism

Analysis Zone

Coupling

Enzyme

Enzyme Enzyme

Enzyme

Filter Coupling ber

Cell wall Bacterium

Enzyme's sterilizing mechanism Cell wall


Coupling

Enzyme Coupling Cell wall Coupling Cell wall Filter ber Filter ber

Filter ber

Enzyme Powerful Powerful effect sterilizing sterilizing effect Powerful sterilizing effect

Powerful sterilizing effect

Powerful sterilizing effect

Photocatalytic washable deodorizing lter


The deodorizing ability of this filter can be easily restored simply byCoupling cleaning and exposing to sunlight

Enzyme

Filter ber

Cell wall Bacterium

Enzyme

This lter will keep the air fresh by deodorizing the molecules that cause odours. The deodorizing effect can be restored by washing with water and then drying under the sun. This lter maintains its deodorizing effect even after many repeat uses.

Cell wall Filter ber

Powerful sterilizing effect

Used Used in models in models

UsedFilter in models Filter


Filter

Used in models

Indoor Unit Unit SRK-ZJX Indoor SRK-ZJX


Indoor Unit

Used in models Photocatalytic Deodorizing Photocatalytic Washable Washable Deodorizing FilterFilter


Filter

Allergen Clear Filter Filter NaturalNatural Enzyme Filter Filter Filter Enzyme Natural Enzyme Filter Allergen Clear Filter Photocatalytic Washable Deodorizing Photocatalytic Washable Deodorizing Filter Filter Allergen Clear Filter Photocatalytic Washable Deodorizing Filter Natural Enzyme Filter Natural Enzyme Filter

Allergen Clear in Filter Used models Allergen Clear Filter

SRK-ZK SRK-ZK SRK-ZJX SRK-ZK 1pc 1pc 1pc Indoor Unit 1pc SRK-ZJX 1pc 1pc Indoor Unit SRK-ZJX SRK-ZK 1pc1pc 1pc 1pc 1pc 1pc 1pc 1pc 1pc 1pc

SRK-ZJ 1pc 1pc SRK-ZK 1pc SRK-ZJ 1pc 1pc 1pc 1pc 1pc --

SRK-ZJ SRK-ZJ

SRF-ZJX SRF-ZJX

SRF-ZJX SRK-ZJ 1pc 1pc SRF-ZJX 1pc 1pc 1pc 1pc 1pc 1pc

SRF-ZJX

1pc 1pc SRF-ZJX

Indoor Unit

1pc 1pc SRK-ZJX

1pc 1pc SRK-ZK

1pc 1pc

13

SRK-ZJ

14

Ceiling Concealed Type.


Wired Remote Control Wireless

RC-EX1A

RC-E5

RCH-E3

RCN-TC-

SRR25~60VF

Standard Equipment

Ceiling concealed type (SRR) Models SRR25ZJ-S, 35ZJ-S, 50ZJ-S, 60ZJ-S


325.4
Control Box

Unit:mm
Symbol Model A Gas piping Liquid piping Drain piping Suspension bolts Power supply intake Content SRR25ZJ-S, 35ZJ-S 9.52 3 8" Flare 6.35 1 4" VP16 M8 35 SRR50ZJ-S, 60ZJ-S 12.7 1 2" Flare Flare

D
30

515 (Suspension bolts pitch)

E
455

B C D E

Wireless remote controller 150

Wired remote controller


Option

30

35

670 (Suspension bolts pitch) 740 90

35 105.7

253

60

17.3

120

19

105 30 19

220

220

105 11.2

Terminal block Air outlet

Note 1 The model name label is attached on the lid of the control box. 2 It takes the interface kit SC-BIKN-E to connect the wired remote controller.

B FIG.B C
Air inlet

148 170

230

52 41

30

150

100

540

100

FIG.A

8- 2.8 Holes for tapping screws

A
38 75

135 236

174.4

20
30.3

120 40
18.5 703 In case of filter guide installed (normal condition) (Air inlet from lower) 18.5

40 670 In case of filter guide installed (option) (Air inlet from rear) 35

35

FIG.A

FIG.B

15
5- 3.3( Mark only) Holes for tapping screws 4

710 168 168 168 168 24 24

15 10

11- 2.8 Holes for tapping screws

190

160

40

10

80 40 150
4

13

21
80 11.3 20 23 203.7

15

11

10 15

24 168 168 710 In case of filter guide taken off 168 168

24

10 15

9- 2.8 Holes for tapping screws

23

694 In case of rear panel taken off

MULTI series Air Conditioners 2013

177

32

6-M4 For hanger plate

82

574

84

Ceiling Cassette.
Fits into standard 600 x 600 ceiling
Fits into standard 600 x 600 ceiling

Wired Remote Control

Wired Remote Control


Wired Remote Control

RC-EX1A

Wired Remote Control RC-E5 RCH-E3


RC-EX1A RC-E5 RCH-E3

PRODUCTS

Fits into standard 600 x 600 ceiling

Wireless Remote Control RC-EX1A RC-E5 RCH-E3 Wired Remote Control


Fits into standard 600 x 600 ceiling
Fits into standard 600 x 600 ceiling

Wired Remote Wireless Control Remote Control RC-EX1A RC-E5 RCH-E3 Wireless Remote Control
RC-EX1A Remote RC-E5 Control RCH-E3 Wireless

FDTC25~60VF
FDTC25~60VF

RC-EX1A

Wireless Remote Control

RC-E5 RCH-E3 RCN-TC-24W-ER

RCN-TC-24W-ER RCN-TC-24W-ER
FDTC25~60VF

Taking outside air inside


OA Spacer TC-OAS-E (option) Joint Duct TC-OAD-E (option)

FDTC25~60VF

Quiet operation
(dB)

Wireless Remote Control RCN-TC-24W-ER RCN-TC-24W-ER

FDTC25~60VF

Utilizing OA spacer which comes as optional equipment, outside air can be taken inside.

36

Indoor Unit FDTC


Indoor Unit FDTC (dB) Indoor Unit FDTC

35 34 (dB)

36 33 35 32

Using 1 joint duct: 35 OA comes up to 1.3m3/min. OA Indoor Unit OA FDTC Spacer Spacer Using 2 joint ducts: 34 OA Ceiling OA OA comes from 1.3 to 2.6m3/min. Spacer surface

36

35dB 31 34
300mm 300mm 30 33

Indoor Unit FDTC

CLEARERair flow
OA Spacer louver

29 (dB) 32 36 28 31 33OA Panel Joint Duct Ceiling OA 35 27 30 surface 25 Panel Previous New New 26 Ceiling OA 34 Joint Duct OA 32 29 300mm (Cooling/Heating) (Cooling) (Heating) surface 25 OA 33 IndoorPanel Unit FDTC Joint Duct 28 Previous New New 31 Spacer 32 (Cooling/Heating) New (Cooling) 27 Previous New (Heating) 31 30 (Cooling) (Heating) 26 (Cooling/Heating) Ceiling OA OA 30 surface 25 Panel 29Duct Flexible hose Joint 300mm 29 300mm
300mm
OA

3dB Down 3dB 35dB 36 3dB 34 35dB Down 35 Down 33 34 32dB 33 32 32dB 3dB 35dB 32dB 32 31 Down 30dB 31 3dB 30dB 30 30 30dB 29 Down 29 5dB 5dB 28 32dB Down 28 27 5dB Down 27 26 3dB Down 35dB 30dB 25 26 Down 32dB
36 35 (dB)

(Sound Pressure level in the Lo mode) (dB)


RCN-TC-24W-ER

35dB

5dB Down 30dB

32dB

New shape & angled redirects the air current away from the ceiling, to reduce ceiling stains

28 27 26 25

Compact 5dB and 5dB convenient


Down
600mm

30dB

eiling OA
Panel

face

OAsurface

Ceiling OA

OA

Panel

Joint Duct

Joint Duct

28 Previous New New 248mm Down 600mm drain pump (Cooling/Heating) (Cooling) (Heating) 27 Drain can be discharged upward by 600 hose mm from Flexible 26 the ceiling surface close toFlexible the indoor hose unit. 25 600mm It allows a piping layout with a high degree of freedom 248mm 600mm depending on the installation location. Previous New New 248mm

wireless remote control

600 x 600 ceiling Previous New New Flexible hose Indoor unit size (W:570(Cooling) x D:570) brings easy (Cooling/Heating) (Heating) RCN-TC-24W-ER 600mm

(Cooling/Heating)

(Cooling)

(Heating)

installation for 600 x 600 ceiling and Panel size (700 x 700) is suitable248mm for 600 x 600 ceiling. Height is one of the industry's lowest level at 248mm and weight is Flexible hose 16.5kg only.
600mm 248mm

wireless wireless remote control remote control RCN-TC-24W-ER For wireless control simply insert the RCN-TC-24W-ER infrared receiver

Easy installation
kit on a corner of the panel

Flexible hose 600mm 248mm

wireless remote control RCN-TC-24W-ER


wireless remote control RCN-TC-24W-ER

15

16

Floor Standing.
Wired Remote Control

Wireles

RC-EX1A

RC-E5

RCH-E3

RCN-T

Wired Remote Control

Wireless Remote Control

RC-EX1A

RC-E5

RCH-E3

RCN-TC-24W-ER

SRF25~50ZJX

SRF25ZJX-S, SRF35ZJX-S, SRF50ZJX-S

Sophisticated design
With a classy semi flat front panel in chic white, this series fits in all kinds of rooms and creates a relaxing atmosphere. Choice of wall hanging, oor standing or behind gallery installation is available.

Auto air outlet selection


Heating operation:
When both lower and upper outlets operation and the Auto fan speed mode is selected, the lower outlet will be kept closed for twenty minutes after the start or until room temperature is close to reaching the set point. Then the air outlet will change to both outlets. That state will be maintained until the switch is turned off. Automatic adjustment of lower air outlet direction prevents stirring up of warm air and keeps optimum comfort at oor level.

Cooling operation:
When both lower and upper outlets operation is selected in Cooling or Dry operation, both outlets are kept open for sixty minutes after the start or until room temperature is below set point. Then the air outlet will change to the upper outlet. That state will be maintained until unit is switched off. In case both outlets operation with Auto fan speed mode is selected, the upper outlet will be kept closed for ten minutes after the start or until room temperature is close to reaching the set point. Then the air outlet will change to both outlets in order to spread comfort air to every corner.
Right Rear Downward Left rear Left

Left downward

Right Rear Downward Left rear Left

Easy installation
Piping and drain hose connection can be selected out of 6-directions.

Left downward

Convenient to use operation Rear


Left downward

Right

Right

Rear simultaneous lower and upper air outlets or Besides on/off operation, Left Left rear upper outlet can be selectedDownward by Left the air ow direction button. Further Left rear Downward Left downward control can be selected on the remote control.

MULTI series Air Conditioners 2013

RC-EX1A

RC-E5 RCH-E3

RCN-KIT3-E

Ceiling Concealed Type Medium Static.


PRODUCTS

Wired Remote Control

Wireless Remote

UM50VF
RC-EX1A RC-E5 RCH-E3

RCN-KIT3-E

Wired Remote Control

Wireless Remote Control

FDUM50VF

FDUM50VF

RC-EX1A

RC-E5

RCH-E3

RCN-KIT3-E

FDUM50VF

Low profile
The height of FDUM50 model is only 280mm.

280
280

280

Improved servicing
Fan unit (impeller and motor) can be pulled out from the right side of the unit. Maintenance is available from the right side or from beneath.

Pipe Unit Maintenance hole Service space Fan unit

Flexible hose less than 600mm

600mm drain pump


Drain can be discharged upwards by 600mm from the ceiling surface. It allows a piping layout with a high degree of freedom depending on the installation location.

Flexible hose less than 600mm

Flexible hose less than 600mm

17

18

Ceiling Suspended.

Wired remote control

RC-E5

RCH-E3

Wireless remote control

FDEN50VF

RCN-E-E

Easy installation
Increased freedom of a piping layout The refrigerant pipe from the unit can be arranged in three directions, rear, right and up. The drain pipe can be arranged in two directions, left and right. This will allow a free layout of piping for various installation conditions. The unit can only be serviced from below.

Up Right Rear

Compact and modern design


All models t compactly on the ceiling. Height is 210mm. Up Elegant, modern design featuring rounded edges gives the room a comfortable atmosphere.

Right Rear

Height 210mm

MULTI series Air Conditioners 2013

Control Options.
CnT terminal is equipped

CnT terminal is equiped


PRODUCTS
CnT
XR1 XR2 XR3 XR4 XR5 XR1~4 : DC12v XR5 : 220~240V

Remote surveillance system


common
HOTEL

XR1 XR2 XR3 XR4 XR5

output1 (run) output2 (heat)

HOTEL

Power output3 (comp on) source output4 (alarm) in put

Card key on-off


Super Link Network Interface Wired Remote Control

Wired Remote Control Model Interface Wired Remote Control

Wireless Remote Option Infrared Kit

SRK**ZJ-S SRK**ZJ-S1 SRK**ZJX-S SRK**ZJX-S1 SRK71ZK-S SRF**ZJX-S SRF**ZJX-S1 SRR**ZJ-S FDUM50VF FDTC**VF FDEN50VF Not required RCN-KIT3-E RCN-TC-24W-ER SC-ADNA-E
SCM125ZJ under 25m under m under m under m under m m

SC-BIKN-E Options RC-EX1A RC-E5 RCH-E3

Not required

SC-BIKN-E SC-ADNA-E Options RC-EX1A RC-E5 RCH-E3

RCN-E-E SCM40ZJ SCM50/60ZJ SCM71/80ZJ SCM100ZJ under 25m under 25m under 25m under 25m length for one indoor unit under 40m under 30m under m under 70m total length for all rooms under 15m under 15m under m under 20m lower installation spot of the indoor unit (A) height under 15m under 15m under m under 20m upper installation spot of the indoor unit (B) difference Limit - The maximum piping length of the refrigerant pipes for the outdoor units, and the maximum under 25m under m under 25m maximum height difference of the indoor units (C) under 25m height difference for the outdoor units are as shown below. 40m 30m m 40m precharged to refrigerant pipe length

Refrigerant Pipe Length


SCM40ZJ-S SCM50/60ZJ-S

SCM71/80ZJ-S

SCM100ZJ-S

SCM125ZJ-S

B C A C

B C

B C

B C

Maximum refrigeration pipe run metres length for one indoor unit total length for all rooms height difference lower installation spot of the indoor unit (A) upper installation spot of the indoor unit (B) maximum height difference of the indoor units (C) pre charged to refrigerant pipe length

SCM40ZJ 30 15

SCM50/60ZJ 25 40

SCM71/80ZJ 70 20 25

SCM100/125ZJ 90

30

40

50

19

20

Inverter Multi-Split System.


SCM-ZJ
The multi system allows a single outdoor unit to service up to six indoor units.

Wall mounted type SRK

Ceiling concealed type SRR

4way ceiling cassette type FDTC

Duct connected type FDUM

Individual refrigerant circuit for each indoor unit


Floor type SRF Ceiling suspended type FDEN

Outdoor Unit

SCM40ZJ-S1 / SCM50ZJ-S1 SCM60ZJ-S1

SCM71ZJ-S1 / SCM80ZJ-S1

SCM100ZJ-S1/ SCM125ZJ-S1

MULTI series Air Conditioners 2013

SCM40ZJ-S 2 Rooms 1 Phase 230V 50Hz 4.0(1.8~5.9) 4.5(1.4~6.9) 0.84 0.90 4.76 5.00 3.7 4 25A 60 62 640X850X290 47 6.35 X 2 9.52 X 2 (9.52 12.7) X 1 Flare connection 2.0 30 mtrs 2.0,2.5,3.5 2.0,2.5,3.5 5.0 2.0,2.5,3.5 2.0,2.5,3.5,5.0 2.0,2.5,3.5 5.0,6.0 40 mtrs 2.5 3.15 6 50 mtrs 2.0,2.5,3.5,5.0 2.0,2.5,3.5 5.0,6.0 7.1 2.5,3.5 5.0 2.5,3.5 2.5,3.5 2.5,3.5,5.0 5.0 5.0 2 Units 4.0kW to 6.0kW 4.0kW to 8.5kW 2 to 3 Units 4.0kW to 11.0kW 4.0kW to 12.6kW 2 to 4 Units 4.0kW to 13.5kW 4 to 5 Units 8.0 kW to 16kW 4 to 6 Units 8.0kW to 19.5kW 2.5,3.5,5.0 2.5,3.5 5.0 2.5,3.5,5.0,6.0 2.5,3.5,5.0,6.0 2.5,3.5 5.0 (9.52 12.7) X 2 (9.52 12.7) X 2 9.52 X 3 9.52 X 3 9.52 X 4 6.35 X 3 6.35 X 3 6.35 X 4 6.35 X 4 9.52 X 4 (9.52 12.7) X 2 48 49 62 6.35 X 5 9.52 X 5 (9.52 12.7) X 2 750X880X340 65 65 66 66 62 63 65 66 68 71 945X970X370 92 6.35 X 6 9.52 X 6 (9.52 12.7) X 2 69 72 5.8 6.8 8.8 10 12.8 4.7 6.5 7.6 9.4 12.4 4.58 4.50 4.30 4.12 4.1 4.63 4.20 4.08 3.70 3.5 1.31 1.51 2.00 2.26 2.93 1.08 1.43 1.74 2.16 2.86 3.9 3.25 3.21 4.15 17 14.1 6.0(1.4~7.5) 6.8(1.5~7.8) 8.6(1.5~9.4) 9.3(1.5~9.8) 12 13.5 5.0(1.8~7.1) 6.0(1.8~7.5) 7.1(1.8~8.8) 8.0(1.8~9.2) 10 12.5 2~3 Rooms 2~4 Rooms 4~5 Rooms 4~6 Rooms

SCM50ZJ-S1

SCM60ZJ-S1

SCM71ZJ-S1

SCM80ZJ-S1

SCM100ZJ-S1

SCM125ZJ-S1

Power Supply

Outdoor

Rated Capacity

Cooling T1

kW

Heating H1

kW

Electrical Input

Cooling T1

kW

Heating H1

kW

EER

Cooling T1

COP

Heating H1

Current

Cooling T1

Heating H1

Rec Circuit Breaker

Sound Power Level (JIS C9612)

Cooling (Outdoor)

dB (A)

Heating (Outdoor)

dB (A)

External Dimensions

(HXWXD)

mm

Net weight

Outdoor

kg

Liquid Line

mm

Refrigerant Piping

Gas Line

mm

Union

mm

Connection Method

Refrigerant R410A

Volume

kg

Pre-Charged

SRK*ZJS/S1

SRK*ZJX

SRK*ZJX-S1

SRK*ZK-S

Indoor Unit Combination

SRF*ZJX

kW

SRF*ZJX-S1

SRR*ZJ

FDTC*VD

FDUM*VF

FDEN*VF

Indoor Unit Connection

Indoor Connection Capacity

kW

Notes 1 Rated data is measured using SRK*ZJX indoor units to match the outdoor unit capacity 2 Currently there is no energy labelling standard for this type of product 3 The kW output capacity, electrical input, current and recommended circuit breaker are indicated at rated kW output capacity. Electrical work must be carried out by a suitably quali ed person and comply to all electrical standards and local regulations.

PRODUCTS

21

22

Multi System Indoor Unit.

SRK-ZJX
High COP wall mount type
FUNCTION

Series
SUN
Comfortable Functions

Operation Filter Filter


Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Lateral
Auto
Swing

Self Clean Allergen

Positioning of installation

Convenient & Economy Functions Economy OFF Timer Sleep

On Timer 24h Timer

DRY

Maintenance & Prevention Functions Self Detachable Diagnostic

MC

Others Back-up Auto Switch Restart

Luminous
24h ION

SPECIFICATIONS
Item Cooling capacity Heating capacity Cooling Heating Cooling Sound pressure level * Heating Cooling Indoor Air ow Heating Exterior dimensions (H X W X D) Net weight Clean lter Sound power level * Piping Liquid line Gas line Model kW kW dB(A) dB(A) dB(A) dB(A) l/s mm kg mm mm

SRK20ZJX-S

SRK25ZJX-S

SRK35ZJX-S

SRK50ZJX-S

SRK60ZJX-S

2.0 2.5 2.5 3.1 53 55 54 58 Hi:39 Me:30 Lo:21 Hi:41 Me:31 Lo:22 Hi:38 Me:33 Lo:25 Hi:41 Me:34 Lo:27 191-133-83 208-150-83 216-166-125 200-158-116

OUTDOOR UNITS TO BE COMBINED

5.0 6.0 3.5 5.8 6.8 4.5 60 62 58 62 62 59 Hi:43 Me:33 Lo:22 Hi:47 Me:40 Lo:27 Hi:51 Me:41 Lo:29 Hi:42 Me:35 Lo:27 Hi:48 Me:40 Lo:33 Hi:48 Me:41 Lo:34 225-183-133 241-208-141 225-158-83 275-241-175 283-250-183 233-183-134 309X 890X 220 15 Allergen Clear Filter X 1, Photocatalytic Washable Deodorizing Filter X 1 6.35 12.7 9.52 SCM40~125ZJ-S1 SCM50~125ZJ-S1 SCM60~125ZJ-S1

The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.

SRR-ZJ
Ceiling concealed type
FUNCTION

Operation

Self Clean

Comfortable Functions

Convenient & Economy Functions Economy OFF Timer Sleep

On Timer 24h Timer

DRY

Maintenance & Prevention Functions Others Back-up Self Auto Luminous Diagnostic Switch Restart

MC

SPECIFICATIONS
Model Cooling capacity Heating capacity Sound power level* Sound pressure level * Air ow Qty (Hi) Exterior dimensions(H X W X D) Net weight Liquid line Piping Gas line OUTDOOR UNITS TO BE COMBINED Cooling Heating Cooling Heating Cooling Heating kW kW dB(A) dB(A) dB(A) dB(A)
l/s

SRR25ZJ-S
2.5 3.4 54 55 Hi:40 Me:35 Lo:29 Hi:41 Me:38 Lo:31 142 167 22
6.35

SRR35ZJ-S
3.5 4.5 56 57 Hi:42 Me:37 Lo:30 Hi:43 Me:40 Lo:32 150 183

SRR50ZJ-S
5.0 5.8 60 60 Hi:48 Me:42 Lo:33 Hi:48 Me:45 Lo:36 175 217 230x740x455 23
6.35 12.7

SRR60ZJ-S
6.0 6.8 63 63 Hi:51 Me:44 Lo:35 Hi:51 Me:47 Lo:38 208 250

mm kg mm mm

9.52 SCM40~125ZJ-S1

SCM50~125ZJ-S1

SCM60~125ZJ-S1

MULTI series Air Conditioners 2013

Multi System Indoor Unit.


PRODUCTS

SRF-ZJX
Floor type
FUNCTION

Operation Filter Filter

Self Clean Enzyme SUN

Comfortable Functions

Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Air outlet selection

Convenient & Economy Functions Economy OFF Timer Sleep

On Timer 24h Timer

DRY

Maintenance & Prevention Functions Self Detachable Diagnostic

MC

Others Back-up Luminous Auto Switch Restart

SPECIFICATIONS
Model Cooling capacity Heating capacity Sound power level * Sound pressure level * Air ow Exterior dimensions Net weight Clean lter Piping Indoor (H X W X D) Cooling Heating Cooling Heating Cooling Heating kW kW dB(A) dB(A) dB(A) dB(A) l/s mm kg Liquid line Gas line mm mm

SRF25ZJX-S
2.5 3.4 51 51 Hi:40 Me:32 Lo:26 Hi:40 Me:35 Lo:28 150-126-96 175-136-110 18

SRF35ZJX-S
3.5 4.5 52 52 Hi:41 Me:34 Lo:28 Hi:41 Me:36 Lo:31 153-130-106 178-138-123 600X 860X 238

SRF50ZJX-S
5.0 5.8 58 58 Hi:46 Me:42 Lo:32 Hi:47 Me:41 Lo:33 191-160-110 200-166-126 19

Natural Enzyme FilterX1 Photocatalytic Washable Deodorizing FilterX1 6.35 9.52 12.7 SCM40~125ZJ-S1 SCM50~125ZJ-S1

OUTDOOR UNITS TO BE COMBINED

The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.

SRK-ZJ-S1
Wall mount type
FUNCTION

Operation Filter Filter


Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Lateral
Auto
Swing

Self Clean Allergen

SUN

Comfortable Functions

Series
On Timer 24h Timer
Maintenance & Prevention Functions Self Detachable Diagnostic

Positioning of installation

Convenient & Economy Functions Economy OFF Timer Sleep

DRY

MC

Others Back-up Auto Luminous Switch Restart

SPECIFICATIONS
Model Cooling capacity Heating capacity Sound power level * Sound pressure level * Air ow Indoor Cooling Heating Cooling Heating Cooling Heating kW kW dB(A) dB(A) dB(A) dB(A) l/s mm kg Liquid line Gas line mm mm

SRK20ZJ-S/S1
2.0 2.7 49 52 Hi:33 Me:27 Lo:21 Hi:36 Me:31 Lo:24 130-93-80 163-105-83

SRK25ZJ-S/S1
2.5 3.2 50 55 Hi:34 Me:28 Lo:21 Hi:39 Me:31 Lo:24 131-100-83 176-108-85

SRK35ZJ-S/S1
3.5 4.0 58 59 Hi:42 Me:32 Lo:22 Hi:43 Me:37 Lo:25 168-106-83 213-156-101 294X 798X 229

SRK50ZJ-S/S1
5.0 5.8 61 61 Hi:46 Me:37 Lo:26 Hi:45 Me:37 Lo:31 188-130-88 225-170-125

Exterior dimensions (H X W X D) Net weight Clean lter Piping

9.5 Allergen Clear Filter X 1, Photocatalytic Washable Deodorizing Filter X 1


6.35 9.52 12.7 SCM50~125ZJ-S1

OUTDOOR UNITS TO BE COMBINED

SCM40~125ZJ-S1

23

24

Inverter Multi Split System.

SRK-ZK
Wall mounted type
FUNCTION

Series
SUN
Comfortable Functions

Operation Filter Filter


Comfortable Air Flow Functions Auto Flap Memory Air Scroll UP/DOWN Lateral
Swing

Self Clean Allergen

Convenient & Economy Functions Economy OFF Timer Sleep

On Timer 24h Timer

DRY

Maintenance & Prevention Functions Self Detachable Diagnostic

MC

Others Back-up Auto Switch Restart

Luminous
24h ION

SPECIFICATIONS
Item Model

SRK71ZK-S
7.1 8.0 60 61 Hi:49 Me:45 Lo:39 Ulo:26 Hi:46 Me:43 Lo:38 Ulo:35 Hi:19.5 Me:17.5 Lo:14.0 Ulo:8.0 Hi:21.5 Me:19.5 Lo:15.5 Ulo:14.0 318x1098x248 15 Allergen Clear Filter x 1, Photocatalytic Washable Deodorizing Filter x 1 6.35 15.88
SCM100/125ZJ-S1

Nominal cooling capacity Nominal heating capacity

Sound power level * Sound pressure level * Air ow Exterior dimensions (H X W X D) Net weight Clean lter Piping

Cooling Heating Cooling Heating Cooling Heating

kW kW dB(A) dB(A) dB(A) dB(A) CMM mm kg

Liquid line Gas line

mm mm

OUTDOOR UNITS TO BE COMBINED

The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.

FDEN-VF
Ceiling suspended
Wired Remote Control Wireless Remote Control

FUNCTION
Comfortable Functions Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Convenient & Economy Functions On Timer OFF Timer Sleep 24h Timer DRY Maintenance & Prevention Functions Self Diagnostic

MC

Others Back-up Auto Switch Restart

RCN-E-E RC-E5 RCH-E3

SPECIFICATIONS
Item Nominal cooling capacity Nominal heating capacity Sound pressure level * Air ow Exterior dimensions (H xW xD) Net weight Air lter Piping Liquid line Gas line Cooling Heating Cooling Heating Model kW kW dB(A) dB(A) CMM CMM mm kg mm mm

FDEN50VF
5.0 5.8 Hi:39 Me:38 Lo:37 Hi:39 Me:38 Lo:37 Hi:11 Me:9 Lo:7 Hi:11 Me:9 Lo:7 210x1070x690 28 Pocket Plastic net x 2 (Washable) 6.35 12.7 SCM50~125ZJ-S1

OUTDOOR UNITS TO BE COMBINED

The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions. * Indicates Powerful-Hi can be selected. Sound pressure level:Cooling dB(A):46 Heating:46, Air ow:13CMM

MULTI series Air Conditioners 2013

Inverter Multi Split System.

FDTC-VF
4way ceiling cassette type
FUNCTION
Comfortable Functions Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Convenient & Economy Functions On Timer OFF Timer Sleep 24h Timer DRY

PRODUCTS

Fits into standard 600 x 600 ceiling

Wired Remote Control

Wireless Remote Control

Maintenance & Prevention Functions Self Diagnostic

MC

Others Back-up Auto Switch Restart

RC-EX1A

RC-E5

RCH-E3

RCN-TC-24W-ER

SPECIFICATIONS
Item Nominal cooling capacity Nominal heating capacity Sound pressure level * Air ow Exterior dimensions (H X W X D) Net weight Piping Cooling Heating Cooling Heating Main unit Panel Main unit Panel Liquid line Gas line Model kW kW dB(A) dB(A) CMM CMM mm mm kg kg mm mm

FDTC25VF
2.5 3.4 Hi:36 Me:32 Lo:29 Hi:38 Me:33 Lo:29.5 Hi:9 Me:8 Lo:6.5 Hi:9.5 Me:8.5 Lo:7

FDTC35VF
3.5 4.5 Hi:40 Me:36 Hi:42 Me:35 Hi:9.5 Me:9 Hi:10 Me:9

FDTC50VF

FDTC60VF
6.0 6.8 Hi:46 Me:39 Lo:30 Hi:46 Me:39 Lo:32 Hi:13.5 Me:10 Lo:7 Hi:13.5 Me:10 Lo:8

5.0 5.8 Hi:42 Me:36 Lo:30 Lo:30 Hi:42 Me:36 Lo:32 Lo:32 Hi:11.5 Me:9 Lo:7 Lo:7 Lo:8 Hi:11.5 Me:9 Lo:8 248x570x570 35x700x700 15 3.5

6.35 9.52 SCM40~125ZJ-S1 SCM50~125ZJ-S1

6.35 12.7 SCM60~125ZJ-S1

OUTDOOR UNITS TO BE COMBINED

The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions. * Indicates Powerful-Hi can be selected. Sound level dB(A):25VF(Cooling:38 Heating:39), 35VF(Cooling:41 Heating:43), 40/50/60VF(Cooling:47 Heating:47), Air ow:25VF(Cooling:10 Heating:10.5), 35VF(Cooling:11 Heating:11.5), 50/60VF(Cooling:13.5 Heating:13.5)

FDUM-VF
Ducted connected-low/middle static pressure
Filter KIT UM-FL1EF (option)
FUNCTION
Comfortable Functions Convenient & Economy Functions On Timer OFF Timer Sleep 24h Timer DRY Maintenance & Prevention Functions Self Diagnostic

Wired Remote Control

Wireless Remote Control

MC

Others Back-up Auto Switch Restart

RC-EX1A

RC-E5

RCH-E3

RCN-KIT3-E

SPECIFICATIONS
Item Nominal cooling capacity Nominal heating capacity Sound pressure level * Air ow Exterior dimensions (H xW xD) Net weight Air lter Liquid line Gas line OUTDOOR UNITS TO BE COMBINED Piping Cooling Heating Cooling Heating Model kW kW dB(A) dB(A) CMM CMM mm kg mm mm

FDUM50VF
5.0 5.8 Hi:32 Me:29 Lo:26 Hi:32 Me:29 Lo:26 Hi:10 Me:9 Lo:8 Hi:10 Me:9 Lo:8 280x750x635 29 Procure locally 6.35 12.7 SCM50~125ZJ-S1

The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions. * Indicates Powerful-Hi can be selected. Sound pressure level dB(A):Cooling:37 Heating:37, Air ow:13CMM

25

26

Dimension Outdoor Unit.


Models SCM40ZJ-S, 45ZJ-S SCM40ZJ-S
286.4 43.5 13.5

Models SCM50ZJ-S1, 60ZJ-S1 SCM50ZJ-S1 SCM60ZJ-S1


286.4
Examples of Installation Dimensions L1 L2 L3 600 100 100

43.5

13.5

50 12

50 12

Examples of Installation Dimensions L1 L2 L3 600 100 100

103.2

312.5 340

14.6 14

385.9 476 203.1 510 850 136.9 65

Unit:mm

49.6

312.5 340

290

49.6

2-16x12 17.9 Terminal block

14

Unit:mm Terminal block Service panel

136.9

B
Service panel 640

B
640 42.7 42.7
20

C A

211

100.3

15

124.1
Intake L2 Intake Outlet L1 L3 No obstacles Service space for electrical parts

34.6
Intake L3 No obstacles Service space for electrical parts Outlet L1 L2

Symbol A B C D E

Content Service valve connection gas side Service valve connection liquid side Pipe cable draw-out hole Drain discharge hole Anchor bolt hole

9.52 3 8" 6.35 1 4" 20 x 3 places M10 x 4 places

Flare Flare

Intake

Symbol A B C D E

Content Service valve connection gas side Service valve connection liquid side Pipe cable draw-out hole Drain discharge hole Anchor bolt hole

100.3

15

42.7

C A

20
20

20
9.52 3 8" 6.35 1 4" 20 x 3 places M10 x 4 places Flare Flare

Minimum installation space

Minimum installation space

Models SCM71ZJ-S1, 80ZJ-S1 SCM71ZJ-S1 SCM80ZJ-S1


47.5
2-R7

Model SCM100ZJ-S1 SCM100ZJ-S1


15

223
.5

310

60 15

15

Symbol A B C D E

Content Service valve connection gas side Service valve connection liquid side Pipe cable draw-out hole Drain discharge hole Anchor bolt hole 20 x 3places M10 x 4places 9.52 3 8" 6.35 1 4" Flare Flare

380 418

340

Examples of Installation Dimensions L1 L2 L3 600 100 100

177

580 970

Center of gravity
73

26

61

20

61 150

Unit:mm

580 880

150 73

26

19 Terminal block

52

L2

L3

Intake No obstacles Service space for electrical parts Outlet

945

115.2 52 219.2 52 323.2 52 427.2 531.2

B
52

C A
190 20 40 60

52

Intake L1 Service space

393

Minimum installation space

750

52

110.4 52 214.4 52 318.4 422.4

76

580

200

10

Center of gravity

Terminal block

Rear panel

410 370

24

55

C A

185
Intake L2 Intake
Outlet L1

10
20 262.8
Examples of installation

40

L3

Symbol A No obstacles B Service space for electrical C parts D E

Content Service valve connection gas side Service valve connection liquid side Pipe cable draw-out hole Drain discharge hole Anchor bolt hole

325

9.52 3 8" 6.35 1 4" 20 x 3 places M10 x 4 places

Flare Flare

Dimensions

Minimum installation space

L1 L2 L3

Open 300 150

Open 5 300

500 Open 150

170

10

Model SCM125ZJ-S1 SCM125ZJ-S1


15

15

Symbol A B C D E

Content Service valve connection gas side Service valve connection liquid side Pipe cable draw-out hole Drain discharge hole Anchor bolt hole 20 x 3places M10 x 4places 9.52 3 8" 6.35 1 4" Flare Flare

177

580 970

Center of gravity
73

26

52

L3 L2

52

945

Intake No obstacles Service space for electrical parts Outlet

52

115.2 52 219.2 52 323.2 52 427.2 531.2 635.2

Intake L1 Service space

393

190 20 40 60 76

580

200

Terminal block

10

Center of gravity

Minimum installation space

Rear panel

20

40

410 370

55

C A

262.8

325

300 5 Open MULTI series Air Conditioners 2013 150 300 150
170 10

Examples of installation Dimensions L1 L2 L3

Open

Open

500

SPECIFICATIONS

27

Before starting use


Heating performance
The heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7C and indoor temperature of 20C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops, if the outdoor temperature is too low and the heating performance is insuf cient, use other heating appliances as well.

Refrigerant leakage
The refrigerant (R410A) used for Air conditioner is non-toxic and non ammable in its original state. However, in consideration of a state where the refrigerant leaks into the room, measures against refrigerant leaks must be taken in small rooms where the tolerable level could be exceeded. Take measures by installing ventilation devices, etc.

Indication of sound values


The sound values are the values (A scale) measured in a chamber such as an anechoic chamber following the ISO Standards. In the actual installation state, the value is normally larger than the values given in the catalog due to the effect of surrounding noise and echo. Take this into consideration when installing.

Use in snowy areas


Take the following measures when installing the outdoor unit in snowy areas.

Snow prevention
Install a snow-prevention hood so that the snow does not obstruct the air intake port or enter and freeze in the outdoor unit.

Use in oil atmosphere


Avoid installing this unit in as atmosphere where oil scatters or builds up, such as in a kitchen or machine factory. If the oil adheres to the heat exchanger, the heat exchanging performance will drop, mist may be generated, and the synthetic resin parts may deform and break.

Snow piling
In areas with heavy snow fall, the piled snow could block the air intake port. In this case, a frame that is 50cm or higher than the estimated snow fall must be installed underneath the outdoor unit.

Use in acidic or alkaline atmosphere


If this unit is used in acidic atmosphere such as hot spring areas having high level of sulfuric gases or in alkaline atmosphere including ammonia or calcium chloride, places where the exhaust of the heat exchanger is sucked in, or at coastal areas where the unit is subject to salt breezes, the outer plate or heat exchanger, etc., will corrode. Please ask a dealer or specialist when you use an air conditioner in places differing from a general atmosphere.

Automatic defrosting device


If the temperature is low, and the humidity is high, frost will stick to the heat exchanger of the outdoor unit. If use is continued, the heating performance will drop. The Automatic defrosting device will function to remove this frost. After heating for approx, three to ten minutes, it will stop, and the frost will be removed. After defrosting, hot air will be blown again.

Use in places with high ceilings

Servicing the air-conditioner


After the air-conditioner is used for several seasons, dirt will build up in the air-conditioner causing the performance to drop. In addition to regular servicing, we recommend the maintenance contract (charged for) by a specialist.

If the ceiling is high, install a circulator to improve the heat and air ow distribution when heating.

Safety Precautions
Air-conditioner usage target
The air-conditioner described in this catalog is a dedicated cooling/heating device for human use. Do not use it for special applications such as the storage of foodstuffs, animals or plants, computer server rooms, precision devices or valuable art, etc. This could cause the quality of the items to drop, etc. Do not use this for cooling vehicles or ships. Water leakage or current leaks could occur.

Installation
Always commission the installation to a dealer or specialist. Improper installation will lead to water leakage, electric shocks and res. Make sure that the outdoor unit is stable in installation. Fix the unit to stable base.

Usage place
Do not install in places where combustible gas could leak or where there are sparks. Installation in a place where combustible gas could be generated, ow or accumulate, or places containing carbon bers could lead to res.

Before use
Always read the User,s Manual thoroughly before starting use.

Only persons that are quali ed and licensed are permitted to install and service products that contain refrigerants in Australia, go to www.arctick.org. Suitable access for service must be provided in compliance with industry standards and local regulations.

MHIAA is proudly sponsoring Monikas Doggie Rescue

Australia:
ABN 92 133 980 275

New Zealand:
G.S.T. 105-673-620

Phone: 1300 138 007


NSW & Head Of ce
9C Commercial Road Kingsgrove NSW 2208 PO Box 318 Kingsgrove NSW 1480

Fax: 1800 644 329


Victoria
2/24 Lakeside Drive Burwood East VIC 3151

Phone: 0800 138 007 Fax: 09 442 5346


Queensland
5/26 Flinders Parade North Lakes QLD 4509

Western Australia
Unit 3A 2 Mulgul Rd Malaga WA 6090 PO Box 667 Belmont WA 6104

Auckland
Unit 2 100 Bush Road Albany 0632 PO Box 300552 Albany 0632

www.mhiaa.com.au

www.mhiaa.co.nz
www.mrespareparts.com.au Tel: +61 (0) 2 9600 7444 Fax: +61 (0) 2 9600 8044

MRE SPARE PARTS

ISO9001
Our Air Conditioning & Refrigeration Systems Headquarters is an ISO9001 approved factory for residential air conditioners and commercial-use air conditioners (including heat pumps).

ISO14001
Our Air Conditioning & Refrigeration Systems Headquarters has been assessed and found to comply with the requirements of ISO14001.
ISO 14001
Certi cate 04104 1998 0813 E5 BIWAJIMA PLANT MITSUBISHI HEAVY INDUSTRIESMAHAJAK AIR CONDITIONERS CO.,LTD.
Certi cate Number : 04104 1998 0813 E5

Certi ed ISO 9001 Certi cate Number : 04100 1998 0813

Because of our policy of continuous improvement, we reserve the right to make changes in all speci cations without notice. E&OE.