You are on page 1of 3

Mix Design for Concrete

C1.Design stipulation: i Characteristic Compressive strength ii Maximum size of aggregate iii Degree of workability iv Degree of quality v Type of Exposure C2. Test data for materials (i) Cement used (ii) Specific gravity of Cement (iii) Specific gravity Fine Aggregate Coarse Aggregate (iv) Water absorption Fine Aggregate Coarse Aggregate (v) Free Surface Moisture Fine Aggregate Coarse Aggregate (vi) Fine Aggregate confirming the table 4, 383- Zone C3.Target mean strength = C4. Selection of Water Cement ratio Water Cement ratio = 31.60 = = = = = = = = = = = = = IS =

Grade = M 25
25 20 0.8
Good Mild PPC N/mm2 mm

3 2.8 2.61 2.1 0.78 2.1


% % % Nil % Zone

N/mm2

0.44

(From fig. 1, Is 10262)

C7. Determination of Fine & Coarse aggregate Air entrapped in concrete Actual quantity of concrete "V" = =

% (From Table 3, IS 10262) 0.98 Cum

Materials required for concrete Grade M 25 1 Concrete quantity =


Sl. No 1 Cement 2 Fine Aggregate 3 Coarse Aggregate 20mm 4 Coarse Aggregate 10mm 5 Water 6 Slump 7 W/C ratio Material name Quantity 422.73 565.72 709.71 473.14 183.63 75 - 100 0.44

Cum
Unit kg kg kg kg ltr mm

Prepared by,

Sathiyaseelan
+91 8894770272