ALLSAIF Online UPS

1K/2K/3K/6K VA online UPS True double-conversion online UPS LCD Display Panelrange (110-300VAC) Wide input voltage Metcom Equipos de Energa Ltda. Input power factor correction 0.98 Diagonal Oriente 1850 Comuna Providencia Ciudad Santiago, Chile Telfono: 205 2517 Output Power Factor 0.8 http://www.metcom.cl/ Generator compatible Email: info@metcom.cl/ RS-232 port or intelligent slot for remote control Smart battery charger design for optimized battery performance Optional compact isolation transformer available for 6KVA model
ALLSAIF 6K with isolation transformer ALLSAIF 3K ALLSAIF 2K ALLSAIF 1K

www.allsai.com

ALLSAIF 1K/2K/3K/6K VA Online UPS Selection Guide


MODEL CAPACITY INPUT Low Line Transfer Voltage Range Low Line Comeback High Line Transfer High Line Comeback Frequency Range Phase Power Factor OUTPUT AC Voltage Regulation (Batt. Mode) Frequency Range (Synchronized Range) Frequency Range (Batt. Mode) Current Crest Ratio Harmonic Distortion Transfer Time AC Mode to Batt. Mode Inverter to Bypass 3 % THD (Linear Load) 6 % THD (Non-linear Load) 4 % THD (Linear Load) 9 % THD (Non-linear Load) Zero 4 ms (Typical) Pure sinewave 86% 83% 12V / 7Ah or 12V / 9Ah 2 27.4 VDC 1% 2 5.0 A 27.4 VDC 1% 54.7 VDC 1% 88% 85% 12V / 7Ah or 12V / 9Ah 4 1.0 A 54.7 VDC 1% 4 5.0 A or 8.0 A 82.1 VDC 1% 82.1 VDC 1% 6 109.2 VDC 1% 8 10 A 109.2 VDC 1% 90% 87% 12V / 7Ah or 12V / 9Ah 6 90% 87% 12 V / 10Ah 8 1% 47.5 ~ 52.5 Hz or 57.5 ~ 62.5Hz 50 Hz 0.25 Hz or 60Hz 0.3 Hz 3:1 4 % THD (Linear Load) 7 % THD (Non-linear Load) 160VAC /140VAC/120VAC/110VAC 5 % or 80VAC/70VAC/60VAC/50 VAC 5 % ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0) 170VAC 5 % or 85 VAC 5 % 300 VAC 5 % or 150 VAC 5 % 290 VAC 5 % or 145 VAC 5 % 47 ~ 53 Hz or 57 ~ 63 Hz (Auto sensing) 175VAC /150VAC/130VAC/110VAC 5 % ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0) 180 VAC 5% 280 VAC 5% 270 VAC 5% ALLSAIF1K(L) 1000 VA / 800 W ALLSAIF2K(L) 2000 VA / 1600 W ALLSAIF3K(L) 3000 VA / 2400 W ALLSAIF6K(L) 6000 VA / 4200 W

Single phase with ground


0.98 (Normal input 220-230Vac @ full load condition)

Waveform (Batt. Mode) EFFICIENCY AC Mode (@1000% RCD load) Battery Mode(@1000% RCD load) BATTERY Battery Type and Numbers Standard Model Battery Numbers Charging Current (max.) Charging Voltage Battery Numbers Long-run Model INDICATORS LCD Panel ALARM Battery Mode Low Battery Overload Fault PHYSICAL Standard Model Long-run Model ENVIRONMENT Humidity Noise Level MANAGEMENT Smart RS-232 / Optional USB card
Optional SNMP

Charging Current (max.) Charging Voltage

UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

Sounding every 4 seconds Sounding every second Sounding twice every second Continously sounding Dimension, D x W x H(mm) Net Weight (kgs) Dimension, D x W x H(mm) Net Weight (kgs) 400x 146 x 205 9.5 400 x 146 x 205 5 397x 140 x 220 17.5 397x 140 x 220 9 20-90 % RH @ 0- 40C (non-condensing) Less than 45dB @ 1 Meter
Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7, Linux, Unix, and MAC Power management from SNMP manager and web browser

421x 190 x 318 29 421x 190 x 318 13 14 0-90 % RH @ 0- 45C (non-condensing) Less than 55dB @ 1 Meter 37

* Only long-run model available * Product specifications are subject to change without further notice