Professional Documents
Culture Documents
Issue Date
V1.5 2011-11-22
Notice
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied.
Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. Please feel free to contact our local office or company headquarters.
Page 2 of 65
CONFIDENTIAL
Summary
This GTSOFTX3000 Configuration Manual was prepared by GTSOFTX3000 team and reviewed by staff from marketing, telecom design, sales, and technical support departments. This Manual will be incorporated into configuration management and be released on the 3MS website after being approved by relevant authority. The recipients of this Manual shall not disclose the information contained in this Manual without permission. Note: This Manual is confidential information of Huwei and shall not be distributed to customers or competitors. In case of violation, the departments or personnel involved shall be held liable. The violator may receive a warning or reduction in salary, or may be fined or dismissed.
History
Date 2010-08-04 Issue 1.00 Details Initial release Author Liao Huanran (ID: 36579)
Page 3 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual 2010-8-10 1.01 Modify Product configuration list: add the following 4 items: 1, S4016497 Cabinet Installation Component 2, 02235831 Wireless Network Product Line,Network Accessories 3, 02236921 IMS 5.0,Installation Suite of N68E-22 Cabinet 4, 02237296 Installation Suite of N68E-PDF 2010-8-11 1.02 Add the item Average busy-hour traffic of CS data service subscribers to Table 2-1 Parameters of the service model Ratio of ordinary subscribers is processed by 1 2010-8-12 1.03 Modify 82200417 Configuration Algorithm: Number of data service subscribers = Total number of subscribers x Ratio of CS data service subscribers Refresh WIFM, WBFI number of configuration principle 1, the largest maximum number of lawful interception centers to 10, with reference to the public network changes 2, License configuration instructions to add a "quotations" Changing PC Server: From HP DL380G6 switch to DELLR510 and IBM3650M3 Add the principles of software configuration items Changing BOM of SMU board: From 03050599 switch to 03053985
Liao Huanran (ID: 36579) Liao Huanran (ID: 36579) Liao Huanran (ID: 36579)
2011-01-14 2011-1-28
1.1 1.2
Liao Huanran (ID: 36579) Liao Huanran (ID: 36579) Xi Hao ID:00103453
Page 4 of 65
CONFIDENTIAL
Contents
1 Overview......................................................................................................................................... 7
1.1 Objective .......................................................................................................................................................... 7 1.2 Product Features ............................................................................................................................................... 7
5 Configuration of the Materials to Be Determined on the Basis of the Site Survey ....... 36
5.1 List of the Materials to Be Determined on the Basis of the Site Survey ........................................................ 36 5.2 Description of the Materials to Be Determined on the Basis of the Site Survey ............................................ 37
Page 5 of 65
CONFIDENTIAL
6.3 Configuration List and Description of External Cables ................................................................................. 48 6.3.1 Configuration List of External Cables .................................................................................................. 48 6.3.2 Configuration Description of External Cables ...................................................................................... 52 6.4 Configuration List and Descriptoin of the Installation Suite .......................................................................... 53 6.4.1 Configuration List of the Installation Suite ........................................................................................... 53 6.4.2 Configuration Description of the Installation Suite .............................................................................. 55 6.5 Configuration List of the N68E PDF Installation Suite ................................................................................. 55 6.6 Configuration List and Description of Network Accessories ......................................................................... 56 6.6.1 Configuration List of Network Accessories .......................................................................................... 56 6.6.2 Configuration Description of Network Accessories .............................................................................. 56
8 Appendix ...................................................................................................................................... 60
8.1 Traffic Model Calculation Tool ...................................................................................................................... 60 8.2 Acronyms and Abbreviations of Board Names .............................................................................................. 60
Page 6 of 65
CONFIDENTIAL
1
1.1 Objective
Only the 750C hardware version of the GTSOFTX3000 is provided.
Overview
This document will be used in the telecom design, sales, and preparation of the commercially-delivered documentation package. It details the composition, configuration list, and configuration principles of GTSOFTX3000 V100R001. It also describes the constraints of the GTSOFTX3000. Documents related to this document include the GSM-R GTSOFTX3000 Configuration Principle, MSOFTX3000 V100R008C03 Configuration Manual, and MSOFTX3000 V100R008C03 Configuration Principle. GTSOFTX3000 V100R001 is based on the 750C hardware platform of MSOFTX3000 V100V006C05.
Using the CPCI hardware platform Supporting 150,000 GSM-R subscribers with one pair of WVDB boards Having the GSM-R software features added Supporting GSM public network services defined by 3GPP
Page 7 of 65
CONFIDENTIAL
Other MSC/VLR
Dispatch station
GTSOFTX3000 PSTN/PBX
GGSN
I n t e r n et
Internet OMC Billing center
AC Server: Acknowledgement Center Server EIR: Equipment Identification Register HLR: Home Location Register MSC: Mobile Switching Center SCP: Service Control Point IWF: InterWorking Function
VLR: Visited Location Register GCR: Group Call Register OMC: Operation and Maintenance Center GGSN: Gateway GPRS Support Node PSTN: Public Switched Telephone Network
FFN: Follow-me Function Node MS: Mobile Station PBX: Private Branch Exchange SGSN: Serving GPRS Support Node AUC: Authentication Center
Page 8 of 65
CONFIDENTIAL
A interface: The MGW connects to the GSM BSS over E1 (SS7/TDM) and acts as the SG to transfer BSSAP signaling. MTUP/MISUP interface: The VMSC server transmits MTUP/MISUP signaling over M3UA. The VMSC server connects to the MGW through the MTUP/MISUP interface. After the transfer of the signaling over the SG built in the MGW, a connection to the PSTN/VMSC/GMSC/TMSC is set up over E1/STM-1 (SS7/TDM). Gs interface: It connects to the SGSN over E1 (SS7/TDM) or IP SIGTRAN. C/D interface: It connects to the HLR over E1 (SS7/TDM) or IP SIGTRAN. E interface: It connects to the VMSC and SMC over E1 (SS7/TDM) or IP SIGTRAN. CAP interface: It connects to the SCP over E1 (SS7/TDM) or IP SIGTRAN. Mc interface: It connects to the MGW over FE (H.248/SCTP/IP). Nc interface: It connects to another VMSC server or GMSC server over E1 (SS7/TDM). PRI interface: The MGW connects to the PBX over E1 and transfers signaling to the GMSC server by using the IUA protocol.
Page 9 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual Parameter Name Handover times per subscriber during busy hours Number of short messages per subscriber during busy hours GMSC parameters Number of trunks required by the GMSC (excluding the trunks to the BSC) Average call duration of ordinary mobile subscribers served by the GMSC Ratio of IN subscribers served by the GMSC Average call duration of IN subscribers served by the GMSC TMSC parameters Number of trunks required by the TMSC (excluding the trunks to the BSC) Average call duration of ordinary mobile subscribers served by the TMSC Ratio of IN subscribers served by the TMSC Average call duration of IN subscribers served by the TMSC Public parameters Ratio of CS data service subscribers Average duration of CS data services Average busy-hour traffic of CS data service subscribers Average busy-hour traffic per trunk Ratio of MS->MS calls Ratio of MS->PSTN calls Ratio of PSTN->MS calls Ratio of toll-call traffic to mobile traffic Ratio of inbound roaming subscribers Ratio of outbound roaming subscribers Radio-channel call loss rate Multi-party service parameters Ratio of multi-party service subscribers 5% Not involved Not involved Not involved Not involved Not involved Not involved Not involved Not involved
Network dependent 60s Network dependent 0.7 Erl 30% 35% 35% 20% 10% 10% 2%
Page 10 of 65
CONFIDENTIAL
Page 11 of 65
CONFIDENTIAL
2 3 4 5 6 7 8
30010850
POC
Page 12 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual 10 11 12 13 14 15 80010052 02314229 02235831 S4016497 02236921 02237296 HUAWEI GT800&GSMR-MSC,license Package MSOFTX3000,KWAM1SERV,Server Unit,Split Wireless Network Product Line,Network Accessories Cabinet Installation Component IMS 5.0,Installation Suite of N68E-22 Cabinet Installation Suite of N68E-PDF
2.
02112622
Page 13 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual SN. 3. Part Number 02351627 Part Description MSOFTX3000, Basic Software Package, for ATO Quantity 0
CONFIDENTIAL Configuration Principle The quantity is one by default. The GTSOFTX3000 software package can be downloaded from the support website, and therefore not contained in the software delivery. Single door for the N68E cabinet; configured by default; two PCS are configured for each cabinet; not configured when a dual-door is required according to the site survey. Dual-door for the N68E cabinet; not configured by default; two PCS are configured when a dual-door is required according to the site survey. The quantity is two by default. The GTSOFTX3000 is configured with one basic subrack and one expansion subrack. The quantity is four by default. Quantity = Number of subracks x2 The GTSOFTX3000 is configured with one basic subrack and one expansion subrack.
4.
21050272
Cabinet Door, DKBA4.120.1089MX, Front/Back Door, N68E-22 Cabinet, Normal P/N: 21050272, 2075mm*594mm*25mm DKBA4.120.1239MX, Front/Back Door(Dual), N68E Cabinet, 2075*594*25
5.
21050282
6.
02300461
7.
03053985
8.
03050148
The quantity is four by default. Quantity = Number of subracks x2 The GTSOFTX3000 is configured with one basic subrack and one expansion subrack.
9.
03050145
The quantity is four by default. Quantity = Number of subracks x2 The GTSOFTX3000 is configured with one basic subrack and one expansion subrack.
Page 14 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual SN. 10. Part Number 03050151 Part Description SoftX3000, SF31WALU0, Alarm Unit Quantity 2
CONFIDENTIAL Configuration Principle The quantity is two by default. Quantity = Number of subracks The GTSOFTX3000 is configured with one basic subrack and one expansion subrack.
11.
03051104
The quantity is two by default. The GTSOFTX3000 is configured with one pair of WCDBs. The quantity is four if the number of subscribers is more than 10,000; the quantity is six if the number of subscribers is more than 50,000.
12.
03051105
The quantity is two by default. The quantity is four if the number of subscribers is more than 5,000; the quantity is six if the number of subscribers is more than 50,000.
13.
03051103
The quantity is two by default. The quantity is four if the number of subscribers is more than 5,000; the quantity is six if the number of subscribers is more than 50,000.
14.
03051106
The quantity is two by default. The GTSOFTX3000 is configured with one pair of WMGCs.
15.
03051107
The quantity depends. The quantity is two when the number of subscribers is no more than 10,000; the quantity is four when the number of subscribers is more than 10,000.
16.
03051111
The quantity depends. The quantity is two when the number of subscribers is no more than 1,000; the quantity is four when the number of subscribers is more than 1,000.
Page 15 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual SN. 17. Part Number 03051110 Part Description MSOFTX3000, SF35WCCU0, Call Control Unit Quantity 2
CONFIDENTIAL Configuration Principle The quantity is two by default. One pair is configured for the GTSOFTX3000. 20 2 2 2 Optional Optional Optional The quantity is two by default. The GTSOFTX3000 is configured with one pair of WVDBs. 6 6 Optional The quantity is six by default. Quantity = Number of subracks x3 The GTSOFTX3000 is configured with two subracks.
MSOFTX3000, SF35WSGU0, Signaling Gateway Unit MSOFTX3000, SF35WAFM0, ATM Forward Module SoftX3000, SF31WBAI0, Back Insert ATM Interface Unit MSOFTX3000, SF35WVDB0, VLR Data Base Unit
22. 23.
03050955 02312525
HLR9820, SF35WEAM0, E1 And ATM Forward Module SGSN9810, KW3M3UPWR, PSM Subrack Power Module
24.
03050932
The quantity depends. The number of WEPIs is equal to the number of WCSUs.
25.
03051558
Finished Board, MSOFTX3000, SF35WCKI0, Clock Interface Unit KVM 4 in 1,1U,17" TFT LCD,8wayKVM,3V3 Power Connector,Black,With Power Cable,Mounting Accessories,English Doc.-48VDC,With eight pieces curving USB KVM Cable,Black Power Cable,3.0m,2.5mm^2,D3F-2S, H07Z-K-2.5^2G&Y+H07Z-K2.5^2BL+H07Z-K-2.5^2B,2*T 2.5^2BL+OT2.5-6,HP Server,LSZH
26.
06040067
27. 04150202
10
When HP DL380G6 is selected for use, 10 PCS are configured for each integrated cabinet.
Page 16 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual SN. 28. Part Number Part Description Quidway S3328TP-EI,CX5Z128DM,S33 28TP-EI Mainframe(24 10/100 BASE-T ports and 2 Combo GE(10/100/1000 BASE-T+100/1000 Base-X) ports and 2 SFP GE (1000 BASE-X) ports (SFP Req.) and DC -48V) DKBA8.081.1062, 3U Dummy Panel, SoftX3000V300R001 DKBA8.081.1063, 1U Non-Standard Dummy Panel, SoftX3000V300R001 DKBA8.081.1061, 2U Dummy Panel, SoftX3000V300R001 DKBA8.081.1060, 1U Dummy Panel, SoftX3000V300R001 DKBA8.805.0475, SoftX3000 9U Subrack Front Board Name Plate, SoftX3000V3R001 DKBA8.805.0476, SoftX3000 9U Subrack Back Board Name Plate, SoftX3000V3R001 DKBA8.805.0480, Rear Board Name Plate of Expanded Subrack, For SoftX3000V300R001 Chassis DKBA4.130.0768MX, K Type, PSM Subrack Filler Panel, Extruded Aluminum Profile DKBA8.807.0277, Huawei Sign, 1U Chassis, 42*14mm, ABS DKBA8.817.2048, MSOFTX3000 Film(Subrack), MSOFTX3000, 50mmX20mm, 0.25 LEXAN 8B35/3M467 DKBA8.807.0429, MOTOROLA Sign, RNC, 42mmX14mm, ABS 1 Quantity
The quantity is four by default. 4 One pair is used for internal networking, and the other is used for MGW/MSCe signaling plane.
02351378
29. 30.
21140431 21140432
1 1
1 1 1 The quantity depends. Quantity = 2 x Number of subracks 1 The quantity depends. Quantity = 2 x Number of basic subracks The quantity depends. Quantity = 2 x [Number of subracks - 1 (basic subrack)] The quantity depends. Quantity = Number of subracks x 34 - Total number of boards 1 The quantity depends. Quantity = Number of subracks 1 The quantity depends. Quantity = Number of subracks
34.
29030287
35.
29030290
36.
21131012
37.
29020181
38.
29050400
39.
29020185
Used for the MOTO project; the quantity is optional. Quantity = Number of subracks
Page 17 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual SN. 40. Part Number 29050579 Part Description DKBA8.807.0702, MSC Server Subrack Film, MSOFTX3000(M), 50mmX20mm, 0.25 LEXAN 8B35/3M9448 DKBA8.812.0012,Blank Qualification Label, ViewPoint Production, 70*46, Fasson 72826/3M 7872 DKBA8.817.1759, Product Blank Nameplate, ViewPoint Production, 70X46, 3M7818 DKBA4.150.1053MX, MOTO Door Nameplate, HLR, 90*30, Plastic DKBA4.150.1049MX, Nameplate for MSOFTX3000(M), MSOFTX3000, 90*30, Plastic DKBA4.150.0901MX, LOGO Plate(for HUAWEI LOGO), GM_Cabinet_N66, Plastic DKBA4.150.0974MX, Nameplate for MSOFTX3000(N68E), MSOFTX3000, 90*30, Plastic 1 Quantity
CONFIDENTIAL Configuration Principle Used for the MOTO project; the quantity is optional. Quantity = Number of subracks
41.
29040013
Mandatory.
42.
29041013
43.
29042542
Two PCS are configured for each N68E cabinet. Used for the MOTO project. Two PCS are configured for each N68E cabinet.
44.
29042543
45.
29042338
Two PCS are configured for each N68E cabinet. Used for the delivery of the MSOFTX3000. Two PCS are configured for each N68E cabinet of the GTSOFTX3000.
46.
29042468
47.
29042471
DKBA4.150.0980MX, Nameplate for MCN90 MSOFTX3000(N68E), MSOFTX3000, 90*30, Plastic Sign Of Network Entry Certificate, (17-5043-060006), 50mm*80mm, 2009/01/09, Mobile Switching System, M900/1800 Sign Of Network Entry Certificate, (17-5043-080747), 50mm*80mm, 2009/03/10, TD-SCDMA Digital Cellular Mobile Telecommunication Network Core Network Subsystem, MCN90
Used for the TD delivery. Two PCS are configured for each N68E cabinet. Used for the GSM delivery in China. One PCS is configured for each cabinet.
48.
29060001
49.
29060433
Used for the TD delivery. One PCS is configured for each cabinet.
Page 18 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual SN. 50. Part Number 29041396 Part Description DKBA8.817.2792,KVM Operating Alarm Film,MSC9880,80mmX40mm, 3M7880 HUAWEI MSOFTX3000 Mobile SoftSwitch Center Quick Installation Guide HUAWEI CN, Engineering Design Document,(HW) Product label,Blank label,192 Groups,24 Row,8 Array,22mm*8mm,DKBA8818 1008,Label Content According To the BOQ of a contract Product label,Blank label,21 Groups,3 Row,7 Array,90mm*25mm,DKBA881 81509,Label Content According To the BOQ of a contract DKBA8.817.8258,Core Network Cabinet Internal Cable Suite Label Set Cable label,DKBA8.818.1040,Signal Cable Engineering label,Matte White,Not Lettering "TO",3 Array,10 Row,30 Groups,84*22mm DPD blank label-24-10X1-195X9.2(mm)-l abel content decided by configure in the cabinet Quantity 1
51.
31504361
52.
31070140
One PCS is configured for the contract that requires pre-installation. Required in large quantities; used in pre-installation for printing board tags.
53.
29100016
54.
29100017
Required in large quantities; used in pre-installation for printing cabinet row/column number tags.
55.
29080013
Required in large quantities; used in pre-installation for printing subrack/equipment tags. Required in large quantities; used in pre-installation for printing cable tags.
56.
29080019
57.
29100002
"Mandatory" means that the item is necessary for the equipment and the customer cannot make a choice. "Optional" means that the item can be configured if required. "The quantity depends." means that the item is mandatory but the quantity is decided by customer's needs.
Page 19 of 65
CONFIDENTIAL
02112626 SoftX3000,SF3B4VMNCN,Voice Module And Network Components NGN Cabinet,N68E-22: It is mandatory in Huawei delivery and MOTO project delivery. 02112622 SoftX3000,SF3B4SPCN,Service Processing New Cabinet,N68E-22: It is used in Huawei delivery and MOTO project delivery. The number of cabinets depends on the number of subracks: Number of cabinets = ROUNDUP [(Number of subracks 2)/4] 21050272 DKBA4.120.1089MX,Front/Back Door,N68E-22 Cabinet,2075*594*25 21050282 DKBA4.120.1239MX,Front/Back Door(Dual),N68E Cabinet,2075*594*25 21050272 is a single door, and 21050282 is a dual-door. The front door and back door can be exchanged. 21050272 is configured by default; two PCS are configured for each cabinet. If a dual-door is required according to the site survey, 21050282 is configured, and two PCS are configured.
02300461
02312525 SGSN9810,KW3M3UPWR,PSM Subrack Power Module: Quantity = Number of subracks x 3. Each subrack is configured with three power boards: two in the front and one at the back, which are installed next to the frame. 2114042921140432 are required in large quantities, but configured according to the needs. 29050400 DKBA8.817.2048,MSOFTX3000 Film(Subrack),MSOFTX3000,50mmX20mm,0.25 LEXAN 8B35/3M467 = Number of subracks 29020181 DKBA8.807.0277,Huawei Sign,1U Chassis,42*14mm,ABS = Number of subracks 29030286 DKBA8.805.0475,SoftX3000 9U Subrack Front Board Name Plate,SoftX3000V3R001 Quantity = 2 x Number of subracks 29030290 DKBA8.805.0480,Rear Board Name Plate of Expanded Subrack,For SoftX3000V300R001 Chassis Quantity = 2 x [Number of subracks - 1 (basic subrack)] 29030287 DKBA8.805.0476,SoftX3000 9U Subrack Back Board Name Plate,SoftX3000V3R001 Quantity = 2 x Number of basic subracks 0305XXXX boards, which are configured according to the quotation. 21131012 DKBA4.130.0768MX,K Type,PSM Subrack Filler Panel,Extruded Aluminum Profile 29041396 DKBA8.817.2792,KVM Operating Alarm Film,MSC9880,80mmX40mm,3M7880: It is mandatory; one PCS is configured. 29020185 DKBA8.807.0429,MOTOROLA Sign,RNC,42mmX14mm,ABS: It is mandatory only in MOTO project delivery; one PCS is configured for each subrack. 29050579 DKBA8.807.0702,MSC Server Subrack Film,MSOFTX3000(M),50mmX20mm,0.25 LEXAN 8B35/3M9448: It is mandatory only in MOTO project delivery; one PCS is configured for each subrack. 29060001 Sign Of Network Entry Certificate,(17-5043-060006),50mm*80mm,2009/01/09,Mobile Switching System,M900/1800 It is the certificate issued by China's Ministry of Information Quantity Quantity
Page 20 of 65
CONFIDENTIAL
Industry to allow the MSOFTX3000's entry into the GSM markets. One PCS is required for each cabinet delivered in Chinese markets.
29060433 Sign Of Network Entry Certificate,(17-5043-080747),50mm*80mm,2009/03/10,TD-SCDMA Digital Cellular Mobile Telecommunication Network Core Network Subsystem,MCN90: One PCS is required for each cabinet delivered for TD-SCDMA projects in Chinese markets. 31504361 HUAWEI MSOFTX3000 Mobile SoftSwitch Center Quick Installation Guide-(03,N68E): It is mandatory when the cabinet 02112626 is delivered; one PCS is required. 02351378 Quidway S3328TP-EI,CX5Z128DM,S3328TP-EI Mainframe(24 10/100 BASE-T ports and 2 Combo GE(10/100/1000 BASE-T+100/1000 Base-X) ports and 2 SFP GE (1000 BASE-X) ports (SFP Req.) and DC -48V): Configured according to the quotation. One pair must be configured for internal networking; the other pair is optional. To ensure the reliability of the signaling network, except for the co-installation of the MGW and MSCe, one pair of LAN switches must be configured for the signaling network.
The configuration description is as follows: 02244409 is the iGWB server software; two PCS are configured in each office, working in active/standby mode. For details on the configuration principle for the iGWB server, see the iGWB Configuration Description (for the SoftX3000, MSoftX3000, and CSoftX3000). 02313066 is the XPTU server unit. For details on the configuration principle for the XPTU server, see the MSOFTX3000 XPTU Lawful Interception Configuration Manual.
Page 21 of 65
CONFIDENTIAL
Note: The configuration 02112628 cabinet, you need to configure the corresponding server power cord, power cord for each IBM X3650M3 Code: 02239872 * 1; each DELL R510 Power Line: (04150183 +04150142 * 2 * 2) * 1; If the expansion is a server or client change (no cabinet, issued a separate server), then each DELL R510 configuration 02230EVD * 1, each IBM X3650M3 configuration 02230EVE * 1. 02245110 is the iGWB server hardware and Operating System; two PCS are configured in each office, working in active/standby mode. For details on the configuration principle for the iGWB server, see the iGWB Configuration Description (for the SoftX3000, MSoftX3000, and CSoftX3000). 02245106 is the emergency workstation and is optional.. When a BAM is configured, the emergency workstation can be configured to work as the standby BAM. 02245107 is the BAM server terminal. In each office, one BAM server and one emergency workstation are configured for the GTSOFTX3000. Either 02319776 or 02319945 is configured. The quantity is one by default. One PCS of 02319946 is configured only when the original configuration has only one GT server.
The principles of software configuration items is as following: Category Part Number 88030RQW Basic Software Part Description MSOFTX3000,Kernel Software(per MSC) MSOFTX3000,Basic Software V100R001(per K sub) MSOFTX3000,AC Server Basic Software-WMFD-202100(per K sub)-WMFD-202100 IP over E1 per k subs Configuration Algorithm If the number of users is not 0, the configuration is 1, otherwise, do not configure Number = the number of users
88030QBQ
Number = the number of users Select the required software Number = the number of users
88034626
Page 22 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual mSoftX3000,TDM 2M signaling link per 2M Links,VMSC MSOFTX3000,Embedded STP function per 64K links,VMSC mSoftX3000,CAMEL phase2 per k subs,VMSC mSoftX3000,CAMEL phase3 per k subs,VMSC CAMEL phase4 per k subs
CONFIDENTIAL
Number = Manual input Number = Manual input Select the required software Number = the number of users Select the required software Number = the number of users Select the required software Number = the number of users If need the software and t Lawful interception function, then: Number = 1000 * the number of users Select the required software Number = the number of users Number = Manual input Select the required software Number = the number of users Select the required software Number = the number of users Select the required software Number = the number of users Select the required software Number = the number of users Select the required software Number = the number of users Select the required software Number = the number of users Select the required software Number = the number of users Select the required software Number = the number of users Select the required software Number = the number of users
88030EKJ
Lawful interception function(per subs)-Server/UMG conbined SCTP multi-homing(per K sub)-Server/UMG conbined mSoftX3000,Multi-PLMN function per PLMN,VMSC Intra-MSC A-Flex(per K sub)-Server/UMG conbined Dual homing from MGW to MSC Server(per K sub)-Server/UMG conbined Update Network Identity and Timezone (NITZ) (per k subs) MSOFTX3000,MSC POOL(1+1 main-standby)(per k sub),WMFD-205300 MSOFTX3000,Call Area Restriction (CAR)(per k sub),WMFD-200400 MSOFTX3000,Multi-Engine Control(per k sub),WMFD-202800 MSOFTX3000,Special Functional Number(per k sub),WMFD-204500 MSOFTX3000,eLDA(Dispatcher mode)(per k sub),WMFD-205100 MSOFTX3000,Master Train List(per k sub),WMFD-205200
88030EKB
88033018
88030PYR
88030QAF
88030QAG
88030QAJ
88030QAK 88030QAM
Page 23 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual MSOFTX3000,Mobile Station Location Service (MSLS)(per k sub),WMFD-205400 MSOFTX3000,Short Message (per k sub),WMFD-010200 MSOFTX3000,Fax Operation(per k sub),WMFD-010300 MSOFTX3000,Bearer Service(per k sub),WMFD-010500 MSOFTX3000,Complementarity Operation(per k sub),WMFD-020100 MSOFTX3000,ODB Function(per k sub),WMFD-030000 MSOFTX3000,Charge Function(per k sub),WMFD-100000 MSOFTX3000,Protocol Interface Function(per k sub),WMFD-110000 MSOFTX3000,Enhanced Group Call & Group Broadcast Function(per k sub),WMFD-200000
CONFIDENTIAL
88030QAN
Select the required software Number = the number of users Select the required software Number = the number of users Select the required software Number = the number of users Select the required software Number = the number of users Select the required software Number = the number of users Select the required software Number = the number of users Select the required software Number = the number of users Select the required software Number = the number of users
88030SVV 88030SVW
88030SVX
88030SVY
88030SWA
88030SWB
88030SWC
88030SWD
Page 24 of 65
CONFIDENTIAL
The license described here is for GTSOFTX3000 V100R001C06. The licenses for different C versions vary. If the quotation is based on TRX, one TRX corresponds to ten subscribers.
Page 25 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual Table 4-2 License configuration related to the basic resource control features Part Numb er 82200 010 (Basic) Part Description Unit for License Quotation Maximum number of concurrent IN calls: 100 to 10,000,000 Configu ration Algorith m Maximu m number of concurren t IN calls = Number of subscribe rs x Ratio of IN subscribe rs x ERL/per IN subscribe rx2 Maximu m number of concurren t data service calls = Number of CS data service subscribe rs x Average Erlang per CS data service subscribe r during busy hours x 2 Quotations
CONFIDENTIAL
Remarks
Traffic
The value is controlled in the DB. When the subscriber or network initiates an IN call, the value increases. When the IN call is released, the value decreases.
Traffic
The value is controlled in the DB. When a mobile subscriber initiates a data service call, the value increases by one. When the data service call is released, the value decreases by one.
Page 26 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual Part Numb er 82200 009 (Basic) Part Description Unit for License Quotation Maximum number of subscribers: 4,000 to 10,000,000 Configu ration Algorith m Enter a specific value: Total number of subscribe rs = Number of subscribe rs specified in the contract Enter a specific value: Total number of lawful intercepti on subscribe rs = Number of lawful intercepti on subscribe rs specified in the contract Quotations
CONFIDENTIAL Remarks
Subscriber
The value is controlled in the DB. When a subscriber is inserted in the VLR, the value increases by one. When a subscriber is deleted from the VLR, the value decreases by one. If the license returns a restriction message, no new subscribers can be inserted in the VLR.
When an interception subscriber is successfully set in the LIC, the value increases by one. When an interception subscriber is deleted from the LIC, the value decreases by one.
Page 27 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual Part Numb er 82200 019 (Basic) Part Description Unit for License Quotation Maximum number of LICs: 0 to 10 Configu ration Algorith m The number of LICs is configure d in accordanc e with the customer' s requireme nt when the lawful intercepti on service is configure d. The default number is 1 if the lawful intercepti on function is required. Quotations
CONFIDENTIAL Remarks
The value increases by one when an LIC is started on the XPTU. The value decreases by one when an LIC is stopped or exits. The invalid license causes the lawful interception function to be unavailable.
Page 28 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual Table 4-3 License configuration related to the special resource control features Part Number 82200413 (Special) Part Description MSOFTX3000,LKWAM AXCONCALL01,Max concurrent calls Unit for License Quotation Maximum number of concurrent calls: 100 to 5,400,000 Configuration Algorithm
CONFIDENTIAL
Quotations Traffic
Remark
Number of concurrent calls = Number of subscribers x (Ratio of IN subscribers x Average busy-hour Erlang of IN subscribers + Average voice-call busy-hour Erlang of ordinary subscribers + Ratio of CS data service subscribers x Average data-service busy-hour Erlang of CS data service subscriber) x 2 Number of CAMEL subscribers = Total number of subscribers x Ratio of CAMEL subscribers
It is cont in the DB When a c initiated, value inc by 2. Wh call is re the value decrease
82200412 (Special)
Subscriber
It is cont in the DB When a CAMEL subscribe inserted VLR, the increases When a CAMEL subscribe deleted f VLR, the decrease If a mess indicatin number i limited, n CAMEL subscribe be insert
Page 29 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual 82200414 (Special) MSOFTX3000,LKWAM AXDATAUSR01,Max Data Service Users Maximum number of data service subscribers: 0 to 5,400,000
CONFIDENTIAL Number of data service subscribers = Total number of subscribers x Ratio of CS data service subscribers Subscriber && Traffic
It is cont in the DB When a d service subscribe inserted VLR, the increases When a d service subscribe deleted f VLR, the decrease If a mess indicatin number i limited, n data serv subscribe be insert
82200417 (Special)
Minimum number of consecutive overload days during a single traffic peak = 1 (carriers except China Mobile) = 3 (China Mobile) Default value: 0 (This item is mandatory. The value is 0 only if the version is upgraded but the license is not upgraded.)
It is cont in the DB value inc by 1 if ov continue occur on day after specified consecut overload If overlo not occu that day, value ret 0.
82200418 (Special)
Maximum number of traffic peaks within a year = 30 (carriers except China Mobile) = 10 (China Mobile)
It is cont in the DB value inc by 1 whe traffic pe occurs w year. The returns to after the passed.
Page 30 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual 82200455 (Special) MSOFTX3000,LKWAVE RLICENSE01,Version Of License File Number of version control items: 127 to 255
CONFIDENTIAL Number of version control items in the license file = 127 (if the quotation is based on the number of subscribers) = 255 (if the quotation is based on the traffic) Default value: 0 (This item is mandatory. The value is 0 only if the version is upgraded but the license is not upgraded.) Subscriber && Traffic
82200479 (special)
Traffic
The valu increases after a gr call is in The valu decrease after a gr call is re
82200480 (special)
The valu increases after a gr added. T value dec by 1 afte group is deleted.
Page 31 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual Table 4-4 License configuration related to the function authorization control features Part Number Part Description Unit for License Quotation Configur ation Corresp onding Functio n List Number WMFD-1 50100, WMFD-1 50200, WMFD-1 51200
CONFIDENTIAL
Quotatio ns
Functio n Switch
81200034 (basic)
Optional function; it must be configured when IN services are required. Optional function; it must be configured when dual-homi ng is required. Basic function, mandatory ; it must be configured when the eMLPP function is required. Optional function; it must be configured when A Flex networkin g is required. Optional function; it must be configured when dual-homi ng is required.
1: Yes 0: No
81200036 (basic)
WMFD-1 60500
1: Yes 0: No
81200039 (basic)
WMFD-2 00300
1: Yes 0: No
81200041 (basic)
WMFD-1 60300
1: Yes 0: No
81200045 (basic)
WMFD-1 60500
1: Yes 0: No
Page 32 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual Part Number Part Description Unit for License Quotation Configur ation Corresp onding Functio n List Number WMFD-2 00300
81200048 (basic)
Basic function, mandatory ; it must be configured when the eMLPP function is required. Optional function; it must be configured when the STP function is required or when 81200039 is required. Optional function; it must be configured when SMS is required. Basic function, mandatory ; it must be configured when the eMLPP function is required.
1: Yes 0: No
81200182 (basic)
WMFD-1 40300
1: Yes 0: No
81200112 (basic)
1: Yes 0: No
81200116 (basic)
WMFD-2 00300
Page 33 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual Part Number Part Description Unit for License Quotation Configur ation Corresp onding Functio n List Number WMFD-1 63400
81200158 (basic)
1: Yes 0: No
81200160 (basic)
MSOFTX3000,LKWASMSI ND01,Sms Indication When Call Failure Function MSOFTX3000,LKWAMSG TRC01,Message Trace Function
WMFD-1 63000
1: Yes 0: No
81200054 (Special)
Basic function; it must be configured . Optional function; it must be configured when CAMEL4 is required. Basic function; it must be configured ; otherwise, calls cannot be connected. Basic function, mandatory ; it must be configured when the MPTY function is required.
WMFD-1 20600
81200208 (Special)
WMFD-1 51200
None
WMFD-0 20500
1: Yes 0: No
81200587 (Special)
Page 34 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual Part Number Part Description Unit for License Quotation Configur ation Corresp onding Functio n List Number WMFD-2 00100, WMFD-2 00200
Basic function, mandatory ; it must be configured when VGCS and VBS are required. Basic function, mandatory ; it must be configured when the MSC call matrix function is required. Basic function; it must be configured . Optional function; it must be configured when the special function number is required.
1: Yes 0: No
WMFD-2 02200
1: Yes 0: No
81200399
None
WMFD-2 04500
Page 35 of 65
CONFIDENTIAL
Length Color (three colors by default: black, blue, and yellow-green) Material
E1 trunk cable BITS clock cable Length-fixed shielded straight-through cable Length-fixed shielded crossover cable Unshielded network cable Installation accessories kit Power cables and signal cables for equipment
Length/impedance Length/impedance Length/quantity Length/quantity Length Type of the floor for installation Stating the types, quantities and lengths
Offer a quotation Not offer a quotation Offer a quotation Offer a quotation Offer a quotation Offer a quotation Not offer a quotation
Page 36 of 65
CONFIDENTIAL
5.2 Description of the Materials to Be Determined on the Basis of the Site Survey
1. 2. 3. Power cable See the description of the external cables. E1 trunk cable See the description of external cables. BITS clock cable See the description of external cables. 4. Network cable and connector A shielded cable (its length is to be decided according to the site survey) is used to connect the GT server to the maintenance console. Two shielded cables (their lengths are to be decided according to the site survey) are used to connect the GT server to the LAN switch. A shielded cable (its length is to be decided according to the site survey) is used to connect the GT server to the external network. See the description of other network accessories. 5. 6. Installation accessories kit See the description of installation accessories kit. Power cable and signal cable See the description of auxiliary equipment.
Page 37 of 65
CONFIDENTIAL
1 1
Page 38 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual SN . 5. Part Number 25050014 Part Description Twisted-Pair Cable,100ohm,,Category 5e UTP,0.51mm,24AWG,8Cores,PANTONE 430U,Use with Plug:14080082 Quantity
CONFIDENTIAL Configuration Principle Not provided by default, but may be configured if required by the 1m site survey
6.
14080082
Network Interface Connector,8Bit 8Pin,Crystal Plug,Matching 25050014 Twisted-Pair Cable,100ohm,Category 5e,FTP,0.52mm,24AWG,8Cores,4Pairs,PA NTONE 430U,Use with Plug:14080097 Network Interface Connector,8-Bit 8PIN,Shielded,Crystal Model Connector,Matching 25050057 Connector Accessories,Shielded Moudlar 8P8C Plug Gray Protection Boot,14080097,1:1,For OEM Tool,Crimping Tool For Shielded Module Plug,Matched 14080114 Nonmetal Parts,DKBA0.480.0457-GT 100M,Wire Strip,100*2.5mm,Strenth 8.1kg Nonmetal Parts,DKBA0.480.0457-GT 150I,Wire Strip,150*3.6mm,Strenth 18.2kg Nonmetal Parts,DKBA0.480.0457-GT-300HD- Wire Clip-295*7.6mm-Strenth 54.4kg Nonmetal Parts,DKBA0.480.0457-GT-300I- Wire Clip-300*3.6mm-Strenth 18.2kg Wrist Strap Product Label,DKBA8.817.0686,Column Label For Forehead Of B-Style Cabinet,1Group Including 20 Pieces (From 00 to 19),Width 54mm&Height 23mm Per Piece Product Label,DKBA8.817.0687,Row Label For Side Door Of B-Style Cabinet,1 Group Including 16 Pieces(From A to P),Diameter 62mm Per Piece
Not provided by default, but may be configured if required by the site survey Not provided by default, but may be configured if required by the site survey Not provided by default, but may be configured if required by the site survey Not provided by default, but may be configured if required by the site survey Optional, but one PCS may be configured if the shielded cable is made on site The quantity required needs to be calculated. The quantity required needs to be calculated. The quantity required needs to be calculated. The quantity required needs to be calculated. Two PCS are configured for each cabinet by default.
7.
25050057
1m
8.
14080097
9.
14990086
10.
02210192
300 300
300
14.
21100144
300
15. 16.
28050001 29040311
17.
29040312
Page 39 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual SN . 18. Part Number 29041061 Part Description Engineering/Blank label,Engineering label,Power Cable label,60 Groups,6 Array,10 Row,Height 11.0,Width 25.0,Matte White,1Pcs/Group Quantity
CONFIDENTIAL Configuration Principle Quantity of power cable labels = ROUNDUP (quantity of power cables/30) + 1 1 The power cables refer to all the -48 V power cables, GND power cables, and PGND power cables. The number 1 refers to one spare label. Quantity of signal labels = ROUNDUP ((quantity of EPI trunk cables x (17/30)) + (quantity of other signal cables/15)) + 1 The EPI trunk cables refer to all the 75-ohm trunk cables (04040441 to 04040445) and 120-ohm trunk cables (04042277 to 04042283). An EPI trunk cable consists of eight E1 lines. Therefore, one cable needs to be configured with 17 labels. Other signal cables refer to all the cables except the power cables. The number 1 refers to one spare label.
19.
29041060
Engineering/Blank label,Engineering label,Signal Cable label,30 Groups,10 Array,3 Row,Height 22.0,Width 84.0,Matte White,1Pcs/Group
20.
21200708
12
Used to fasten the labels to the cable terminals. Quantity = (quantity of 29041060 x 30) + (quantity of 29041061 x 60) (Intermediate layer) Not provided by default, but may be configured if required by the site survey Not provided by default, but may be configured if required by the site survey
21.
02231806
22.
28010123
23.
14990111
Connector Accessories,Protection Boot That Used With D Type Shell Female D-SUB Connector,Matching With DB50/DB78,1:1 DKBA8.817.5799,GTSOFTX3000 Door Mask,GTSOFTX3000,89mm*39mm,0.25 LEXAN 8B35/3M467
24.
29050995
Not configured
Page 40 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual SN . 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 05114580 Part Number 05160127 05160217 05160202 05160233 05113637 05160251 05114286 05114287 05114268 05114269 05114320 Part Description HUAWEI MSC9880,Terminal Software Suite(M) MSoftX3000,Terminal Software Suite,V100R003 MSoftX3000,Terminal Software Suite,V100R003C02 MSoftX3000,Terminal Software Suite,V100R005 GTSOFTX3000,SF3iGWBC34,Terminal Physical Software,Program MSOFTX3000,Terminal Software Suite,V100R005C10 MSOFTX3000,MSOFTX3000 V100R006C02,Product Physical Software MSOFTX3000,MSOFTX3000 V100R006C05,Product Physical Software MSOFTX3000,MSOFTX3000 V100R007C01,Product Physical Software MSOFTX3000,MSOFTX3000 V100R007C02,Product Physical Software MSOFTX3000,MSOFTX3000 V100R008C02,Product Physical Software MSOFTX3000,MSOFTX3000 V100R007C03,Product Physical Software MSOFTX3000,Terminal Software Suite,V100R006 MSoftX3000,Terminal Software Suite,V100R007 MSoftX3000,SF3iGWBS2,Charging Gateway Physical Software Package,Program,V300R005C31,For MSOFTX3000 V100R008C02 MSoftX3000,SF3iGWBS5,Charging Gateway Physical Software Package,Program,V300R005C32,For MSOFTX3000 V100R008C03 MSOFTX3000,MSOFTX3000 V100R008C05,Product Physical Software Quantity
CONFIDENTIAL Configuration Principle Not configured for the GTSOFTX3000 Not configured for the GTSOFTX3000 Not configured for the GTSOFTX3000 Not configured for the GTSOFTX3000 Not configured for the GTSOFTX3000 Not configured for the GTSOFTX3000 Not configured for the GTSOFTX3000 Not configured for the GTSOFTX3000 Not configured for the GTSOFTX3000 Not configured for the GTSOFTX3000 Not configured for the GTSOFTX3000 Not configured for the GTSOFTX3000 Not configured for the GTSOFTX3000 Not configured for the GTSOFTX3000 Not configured for the GTSOFTX3000
1 1 1 1 1 1 1 1 1 1 1 1 1 1
40. 05114657
Not configured for the GTSOFTX3000 Not configured for the GTSOFTX3000
41.
05114956
Page 41 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual SN . 42. 02230EVD 43. 02230EVE Part Number Part Description Subassembly | Accessories,DELL DCR510 Server Independent Delivery Dressing Package Subassembly | Accessories,IBM X3650M3 Server Independent Delivery Dressing Package Quantity
Page 42 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual Table 6-2 Configuration list of the auxiliary equipment SN. 1. Part Number Part Description Quantity 1
CONFIDENTIAL
Configuration Principle Optional The alarm box is provided by the M2000 if the M2000 is available. One alarm box can be configured depending on the networking or customer's requirement. Whether the alarm box is provided depending on the customer's offer.
02100060
2. 3.
04000361
Wireless,Alarm Box Cable Set China Power Cable 250V10A 6m,3PIN Straight Plug /227IEC53(RVV)3x0.75mm^2Black/3PIN Left-angled Connector External Power Cable,30.00m,0.8mm^2,Black,H4(5.08),18SJ T(2C)B,2*H1,C&C08C,DL0945 External Power Cable,40m,0.8mm^2,Black,H4(5.08),18SJT(2 C)B,2*H1,C&C08C External Power Cable,50m,0.8mm^2,Black,H4(5.08),18SJT(2 C)B,2*H1,C&C08C
1 1
Optional Optional The power cables (04040705, 04020199, 04043082, 04043081, and 04043083) are used to supply power to the alarm box. The power cables (04020199, 04043082, 04043081, and 04043083) are -48 V power cables whose lengths need to be decided by the site survey. The power cable 04040705 is a 220
04040705
4.
04020199
5.
04043082
6.
04043081
Page 43 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual SN. 7. Part Number 04043083 Part Description External Power Cable,60.00m,0.8mm^2,Black,H4(5.08),18SJ T(2C)B,2*H1,C&C08C Quantity 1
CONFIDENTIAL Configuration Principle V cable. When installing the alarm box, you must pay attention to the selection of power cables and settings of the power DIP switches. The 220 V AC power cable used is 6 meters long. The -48 V DC power cable is of various lengths: 30m, 40m, 50m, and 60m; the site survey will determine the required length. Before turning on the alarm box, you must check that the power DIP switch is in conformity with the selected power type. 1 Optional The serial cables (04060374, 04043090, and 04043091) are used to transmit signals between the system and the alarm box; the site survey corresponding to lengths of 20m, 30m, and 40m respectively; the site survey will determine the required length. The alarm box of the GTSOFTX3000 is connected to the serial port of the BAM server or the maintenance console through the serial cable. Optional; if required, one PCS is configured. It is installed on the emergency workstation (02244508) to provide a remote maintenance interface.
8.
04060374
Single Cable,GM12 Alarm Box RS232 Serial Port Cable,20.00m,MP8-I,CC4P0.5GY,D9F,GMS C Single Cable,RS232 Serial Port Cable,30m,MP8-I,CC4P0.5GY,D9F+D9(PS) Single Cable,RS232 Serial Port Cable,40m,MP8-I,CC4P0.5GY,D9F+D9(PS)
9. 10.
04043090 04043091
1 1
11.
50030082
Page 44 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual SN. 12. Part Number 02244982 Part Description PC for Core Net(Middle-grade),Chinese OS Quantity 1
CONFIDENTIAL Configuration Principle Mandatory, either one PCS of 02234982 or 02244983 Both 02244982 and 02244983 are hardware workstations of the system, comprising the desktop computer, operating system, and database software. Mandatory, either one PCS of 02234982 or 02244983 Both 02244982 and 02244983 are hardware workstations of the system, comprising the desktop computer, operating system, and database software. Optional, One PCS, if required, is used together with the modem. Optional It is the alarm box used in MOTO delivery. Optional The -48 V PDF needs to be configured if the customer cannot provide multi-port -48 V power. The installation accessories kit for the PDF is the same as that for the service cabinet.
13.
02244983
14.
04060263
Single Cable,MN straight through Conversion Cable,1.00m,D25M,CC16P0.4P430U,D25M, OptiX M900MSC,GM15ALMZ,Universal Alarm Box(M) PDF,-48VDC/1300A input,Chinese & English Document,12 circuits 100A DC output,28 circuits 63A DC output,N68E cabinet PDF
15.
02100050
16.
02400420
Page 45 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual SN. 17. Part Number 02351368 Part Description Quidway S2318TP-EI,CX4Z118AM,S2318TP-EI Mainframe(16 10/100 BASE-T ports and 2 Combo GE(10/100/1000 BASE-T+100/1000 Base-X) ports and AC 110/220V) Quantity 2
CONFIDENTIAL Configuration Principle The quantity is one by default. The matching power cable needs to be selected from 04000104 for use in a specific country. The GT server, BAM, and iGWB need to be configured with a maintenance console, thereby requiring one PCS of 02351368. A port is required for connecting the GT server to the external network. If ports are not sufficient, one more PCS of 02351368 is required.
18.
04070042
Optional with a default length of 30m It connects the host to the EMU alarm box. Customized lengths can be provided according to the site survey.
19.
25050101
Communication Cable,100ohm,UL2919,26AWG,2P,PANTON E WARM GRAY 1U,For OEM Twisted-Pair Cable,100ohm,UL2464,0.32mm,28AWG,1P,P ANTONE WARM GRAY 1U,Only For OEM Carton,DKBA8.865.0226,Carton,For Packing MA5103,610*555*345 Door Magnetic Switch,Always Open,Covert Installation Type,50.8*14.3*12.7mm Liquid Level Sensor-D18*77mm-Cable Length 2700mm Chinese Documents Temperature And Humidity Sensor,15V24VDC,-2080degC/0~100%RH, +/-0.8degC/+/-5%RH(1550degC),4~20mA,C hinese Documents
20.
25050122
1 1 1 1 Optional, sensors for 02100054 If the alarm box is provided, these four sensors must also be provided.
Page 46 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual SN. 25. Part Number 33010293 Part Description Smoke Sensor,24V,Two Line, photoelectric Smoke Sensor, Ceiling Fixed,Chinese information,Terminal Dedicated BTS3606E,QCKG1EMU,BTS Environment Monitor Unit Quantity 1
26.
02100054
27.
04040662
28.
04000279
29.
02315200
Optional One PCS may be configured according to the networking or the customer's requirement. Optional It is the power cable of the EMU alarm box. Two PCS are required. Its length is to be decided by the site survey. Optional The length and quantities will be decided by the site survey. Power cables are available in five colors: blue, black, yellow-green, red, and green. 25030191 (yellow-green cable) is used as the PGND cable. The terminal to be selected is 14170013; two PCS are required for one PGND cable. 25030191: Wire,450/750V,60227 IEC 02(RV) 6mm^2,Yellow And Green,44A 14170013: Naked Crimping Terminal,OT,6mm^2,M 8,Tin Plating,Insulated Ring Terminal,12-10AWG,y ellow It is an optical module, not configured. It is an optical module, not configured.
30.
02315204
Page 47 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual SN. 31. Part Number 02315206 Part Description Datacom Products,DP0M2ESFP,Optical Transceiver,ESFP,GE,Single-mode Module(1550nm,100km,LC) Datacom Products,DP0M8SFP,Optical Transceiver,SFP,GE,Single-mode Module(1550nm,70km,LC) Datacom Products,DP0M9SFP,Optical Transceiver,SFP,GE,Single-mode Module(1550nm,40km,LC) Datacom Products,DP0M10SFP,Optical Transceiver,SFP,GE,Single-mode Module(1310nm,40km,LC) Quantity 0
CONFIDENTIAL Configuration Principle It is an optical module, not configured. It is an optical module, not configured. It is an optical module, not configured. It is an optical module, not configured.
32.
02315468
33.
02315469
34.
02315470
Page 48 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual Table 6-3 Configuration list of external cables S N. 1. Part Number 104000336 Part Description
CONFIDENTIAL
Quantit y Optional
Configurat ion Principle It refers to the coiled power cable, which is used to route power from outside the cabinet. Four colors are available: blue, black, red, and yellow-gree n; inflammatio n-resistant wires in a size of 25mm^2 are used. The length of each cable will be determined by the site survey.
2.
04040446
Trunk Cable,BSC6800,20m,75ohm,8E1,2.2mm,D50M-II,2*SYFVZP75 -1.2/0.25*8(S),BSC6800 Trunk Cable,BSC6800,30m,75ohm,8E1,2.2mm,DB50M-II,2*SYFVZP 75-1.2/0.25*8(S),BSC6800 Trunk Cable,BSC6800,40m,75ohm,8E1,2.2mm,D50M-II,2*SYFVZP75 -1.2/0.25*8(S),BSC6800 Trunk Cable,BSC6800,50m,75ohm,8E1,2.2mm,D50M-II,2*SYFVZP75 -1.2/0.25*8(S),BSC6800 Trunk Cable,BSC6800,60m,75ohm,8E1,2.2mm,D50M-II,2*SYFVZP75 -1.2/0.25*8(S),BSC6800
Optional
3.
04040447
Optional
4.
04040448
Optional
5.
04040449
Optional
6.
04040450
Optional
Page 49 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual S N. 7. Part Number 04040582 Part Description
Single Cable, Conversion Cable,3m,2*SMB75SM-IV,120CC2P0.4P430U(S)+2*SYFVZ75 -1/0.25,MP8-II,Expert 2.0 Trunk Cable,20m,120ohm,8E1/8T1,0.5mm,D50M-II,2*120CC8P0.5P4 30U(S),CBSC Trunk Cable,30m,120ohm,8E1/8T1,0.5mm,D50M-II,2*120CC8P0.5P4 30U(S) Trunk Cable,40m,120ohm,8E1/8T1,0.5mm,D50M-II,2*120CC8P0.5P4 30U(S) Trunk Cable,50m,120ohm,8E1/8T1,0.5mm,D50M-II,2*120CC8P0.5P4 30U(S) Trunk Cable,60m,120ohm,8E1/8T1,0.5mm,D50M-II,2*120CC8P0.5P4 30U(S) Trunk Cable,10m,120ohm,8E1/8T1,0.4mm,D50M-I,2*120CC8P0.4P43 0U(S) Trunk Cable,15m,120ohm,8E1/8T1,0.4mm,D50M-I,2*120CC8P0.4P43 0U(S) Trunk Cable,20m,120ohm,8E1/8T1,0.4mm,D50M-II,2*120CC8P0.4P4 30U(S) Trunk Cable,30m,120ohm,8E1/8T1,0.4mm,D50M-I,2*120CC8P0.4P43 0U(S) Trunk Cable,40m,120ohm,8E1/8T1,0.4mm,D50M-I,2*120CC8P0.4P43 0U(S) Trunk Cable,50m,120ohm,8E1/8T1,0.4mm,D50M-I,2*120CC8P0.4P43 0U(S) Trunk Cable,60m,120ohm,8E1/8T1,0.4mm,D50M-I,2*120CC8P0.4P43 0U(S)
8.
04041486
9.
04041487
Optional
10.
04041488
Optional
11.
04041489
Optional
12.
04041490
Optional
13.
04042277
Optional
14.
04042278
Optional
15.
04042279
Optional
16.
04042280
Optional
17.
04042281
Optional
18.
04042282
Optional
19.
04042283
Optional
Page 50 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual S N. 20. Part Number 04044335 Part Description
Trunk Cable,155M/Clock/Lightning,10m,75ohm,3.9mm,SMB75SF-IV, SYV75-2/0.34(S) Trunk Cable,155M/Clock/Lightning,20m,75ohm,3.9mm,SMB75SF-IV, SYV75-2/0.34(S) Trunk Cable,155M/Clock/Lightning,30m,75ohm,3.9mm,SMB75SF-IV, SYV75-2/0.34(S) Single Cable,Clock Cable,5m,MP8-VI,CC4P0.48B(S),MP8-VI,Subtending Cable for MSOFTX3000 Single Cable,Clock Cable,10m,MP8-VI,CC4P0.48B(S),MP8-VI,Subtending Cable for MSOFTX3000 Single Cable,Clock Cable,20m,MP8-VI,CC4P0.48B(S),MP8-VI,Subtending Cable for MSOFTX3000 Trunk Cable,155M Self-Loop,5m,75ohm,4.0mm,SMB75SF-IV,SYV75-2/0.34(S),S MB75SF-IV,OptiX Trunk Cable,155M/Clock/Lightning,70m,75ohm,3.9mm,SMB75SF-IV, SYV75-2/0.34(S) Trunk Cable,155M/Clock/Lightning,50m,75ohm,3.9mm,SMB75SF-IV, SYV75-2/0.34(S) Signal Cable,Shielded Straight Through Cable,5m,MP8-II,CC4P0.5GY(S),MP8-II,FTP Signal Cable,Shielded Straight Through Cable,10m,MP8-II,CC4P0.5GY(S),MP8-II,FTP Signal Cable,Shielded Straight Through Cable,20m,MP8-II,CC4P0.5GY(S),MP8-II,FTP Signal Cable,Shielded Straight Through Cable,40m,MP8-II,CC4P0.5GY(S),MP8-II,FTP Trunk Cable,25m,75ohm,8E1,2.2mm,D50M-II,2*SYFVZP75-1.2/0.25* 8(S)
21.
04044336
Optional
22.
04044337
Optional
23.
04046698
24.
04046699
25.
04046700
26.
04060171
27.
04060321
28.
04060322
Optional
29.
04070009
30.
04070012
31.
04070013
32.
04070015
33.
04120141
Page 51 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual S N. 34. Part Number 04120142 Part Description
Trunk Cable,35m,75ohm,8E1,2.2mm,D50M-II,2*SYFVZP75-1.2/0.25* 8(S) Trunk Cable,45m,75ohm,8E1,2.2mm,D50M-II,2*SYFVZP75-1.2/0.25* 8(S) Single Cable,Clock Test Cable,1.22m,SMB75SF-IV,SYV75-2/0.34(S),SMB75SF-IV,BIT S,DL4140
35.
04120143
Optional
36.
04025303
Mandator y
Four PCS are required for the cabinet 02112626. It is used to connect the first expansion subrack to the basic subrack. Four PCS are required for each of the cabinet 02112626. It is used in the NTP network for connecting the WCKIc and WHSC. It is required if the WCKIc is provided. Quantity = Number of WCKIc boards x 2
37.
04045542
Optional
38.
Optional
04070002
39.
04070108
Optional
Page 52 of 65
CONFIDENTIAL
cable is the DB50 connector; the connector at the other end and the length of the cable need be determined on the basis of the site survey. The connector used at the other end must be made on site. The principle for configuring the trunk cable is as follows: configure one trunk cable for a pair of EPI boards and connect the cable to the active EPI board. Quantity: Number of EPI boards with the corresponding impedance/2. Note that the 75-ohm and 120-ohm cables must be calculated separately. The connector of the E1 line on the DDF side is provided by the cable rack. The 120-ohm trunk cable is delivered on the basis of the site survey. If there is no specific requirement, 0.4mm-core cables are delivered by default. These trunk cables are delivered to the markets outside china. 2. 04044335, 04044336, 04044337, 04060322, and 04060321 are trunk cables for connecting to the BITS clock device. These cables are used to obtain the clock source from the synchronization system. Quantity = Number of CKI boards x 2. The length of the cable need be determined on the basis of the site survey. Cables of 04070108, 04070009, 04070012, 04070013, or 04070015 or longer cables are used to connect the WCKIc to the NTP network. Quantity = 2 PCS 04060171 and 04040582 are 120-ohm BITS clock cables. 04060171 is mandatory for connecting to the WCKI board; four PCS are required. 04040582 is used for connecting to the BITS device; four PCS are required. For 04040582, an order is required for customized length (120-ohm twisted pair cable). 04041486, 04041487, 04041488, 04041489, and 04041490 are 120-ohm trunk cables with the 0.5 mm core, which are used for the WEPI board.
3. 4.
5.
The lengths of external cables need be determined on the basis of the site survey. If, according to the site survey, the cable required is longer than the length specified in the list, select the cable with the maximum length in the list, and record the actually required length of the cable. The dispatching personnel will be responsible for arranging the trial production of the cable.
Page 53 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual SN. 2 Part Number 21150584 Part Description DKBA4.070.0722MX,N6X Cement Floor Mount Kit,For Mount in Cement Floor,Cement Floor Mount structure Q/DKBA8.088.0783,Installation Marking Template,N68-22 Cabinet(Cement Floor)
CONFIDENTIAL Quantity and Configuration Principle One PCS is required for each cabinet that stands on the cement floor. The quantity required depends on the site survey. One PCS is required for each cabinet that stands on the cement floor. The quantity required depends on the site survey. One PCS is required for each cabinet that stands on the antistatic floor. The quantity required depends on the site survey. It is used to support the cabinet that stands on the antistatic floor. It is selected depending on the height of the antistatic floor (the height refers to the distance between the antistatic floor and the ground). Two options are available. Two PCS are required for each cabinet. The quantity required depends on the site survey.
21101201
21100577
Non-metallic Component-Q/DKBA8.088.0784-Installation Marking Template -N68-22 Cabinet (Antistatic floor) DKBA4.070.0711MX,N6X Unitary Support Mount Kit I(Adjustable Height 296465mm),For mounting on antistatic floor,Support DKBA4.070.0718MX,N6X Unitary Support Mount Kit II(Specific Height H>=100mm),For mounting on antistatic floor,Support
21150568
21150569
21150572
DKBA4.070.0670MX,Top Fixing Mount Kit,For the top of cabinet fixed,Engineer Installation Structure
It is used for the connection between the equipment and the cable rack and for securing devices. It is not delivered by default. If there are N cabinets in a row, N+1 PCS are required. It is not delivered by default but can be provided depending on the site survey. The wire trough is two meters long. It must be used together with the wiring ladder. It is used for reinforcement and quake-proof purposes by connecting the top of the equipment to the ceiling or walls. It is not delivered by default. The quantity required depends on the site survey. One PCS is required for each cabinet. It is not delivered by default but can be provided depending on the site survey. The wiring ladder is 2.5 meters long. It is not delivered to the Shelter telecom room.
21150223
21150259
10
21150483
Page 54 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual SN. 11 Part Number 21150485 Part Description DKBA4.070.0490MX,Wiring ladder Indoor Accessories and Consumable Kit, Roll molding Insulation Material,Fireproof PVC Corrugated Tube,D25 DKBA8.817.2045,PDF Film(Door),RNC,89mmX39mm,0.25 LEXAN 8B35/3M467
CONFIDENTIAL Quantity and Configuration Principle It is not delivered by default but can be provided depending on the site survey. It is not delivered by default but can be provided depending on the site survey. Two PCS are required if the DC PDF is in use.
12
28010026
13
29050406
02237345
Page 55 of 65
CONFIDENTIAL
2. 3. 4. 5.
6. 7.
14990086 25050057
1PCS 1m
Optional Optional
25050014 Twisted-Pair Cable,100ohm,,Category 5e UTP,0.51mm,24AWG,8Cores,PANTONE 430U,Use with Plug:14080082 14080082 Network Interface Connector,8Bit 8Pin,Crystal Plug,Matching 25050014 25050014 and 14080082 are used to make ordinary network cables on site. They are provided according to the site survey.
02235830 02235829
02235830 and 02235829 are length-fixed network cables and are not configured by default. The length and quantity of the cable required are determined on the basis of the site survey.
Page 56 of 65
CONFIDENTIAL
14080097 Network Interface Connector,8-Bit 8PIN,Shielded,Crystal Model Connector,Matching 25050057 14990086 Connector Accessories,Shielded Moudlar 8P8C Plug Gray Protection Boot,14080097,1:1,For OEM 25050057 Twisted-Pair Cable,100ohm,Category 5e,FTP,0.52mm,24AWG,8Cores,4Pairs,PANTONE 430U,Use with Plug:14080097 25050057, 14080097, and 14990086 are used to make shielded network cables on site. They are not delivered by default but can be provided according to the site survey.
Page 57 of 65
CONFIDENTIAL
Page 58 of 65
CONFIDENTIAL
Page 59 of 65
CONFIDENTIAL
8
8.1 Traffic Model Calculation Tool
model, see
Appendix
For the method of calculating system capacity based on the number of subscribers and traffic
Page 60 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual Abbreviation WCDB WVDB WMGC UPWR Full Spelling Central Data Base unit VLR Data Base unit Media Gateway Control unit Universal Power
CONFIDENTIAL
Note that the letter W at the beginning of the board name represents wireless.
Page 61 of 65
CONFIDENTIAL
9
Abbreviation AAL AAL2 ALU AMR ARP BAIC BAM BAOC BAU BFI BIC-Roam B-ISDN BOIC BOIC-exHC BSSAP CB CCU CFNRc CFU CLIP CLIR
Table 9-1 Acronyms and abbreviations Full Spelling ATM Adaptation Layer ATM Adaptation Layer type 2 Alarm Unit Adaptive multi Rate Address Resolution Protocol Barring of All Incoming Calls Back Administration Module Barring of All Outgoing Calls Bill Administration Unit Bad Frame Indication Barring of Incoming Calls When Roaming Outside Home PLMN Country Broadband Integrated Services Digital Networks Barring of Outgoing International Calls Barring of Outgoing International Calls except those directed to the Home PLMN Country Base Station Subsystem Application Part Cell Broadcast Channel Codec Unit Call Forwarding on mobile subscriber Not Reachable Call Forwarding Unconditional Calling Line Identification Presentation Calling Line Identification Restriction
Page 62 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual Abbreviation CODEC CoLP CoLR CPC cPCI CPU CUG DDN DTMF ESP EtherNet FEP FLASH FTP GE GLONASS GMLC HLR HOLD HSC HSTP HW ICMP IDP IFM IIN IMSI IN ISDN ISS Front End Processor FLASH memory File Transfer Protocol Gigabit Ethernet GLObal NAvigation Satellite System Gateway Mobile Location Center Home Location Register Call Hold Hot Swap Controller High-level Signaling Transfer Point Highway Internet Control Message Protocol Individual Development Plan IP Forward Module Integrated Intelligent Network International Mobile Subscriber Identity Intelligent Network Integrated Services Digital Network Integrated Service Server Central Processing Unit Closed User Group Digital Data Network Dual Tone Multi Frequency Early Support Program Full Spelling Coder-decoder Connected Line Identification Presentation Connected Line Identification Restriction Central Processing Board
CONFIDENTIAL
Page 63 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual Abbreviation ITU-T IU IWF LAN LSTP MAP MML MODEM MSISDN MSRN MTP MTP2 MTP3 MTP3b RARP RDI SCTP SDF SDH SGU TCU TDMA TFO TMSI TUP UDI UDP UE UL UMTS Full Spelling
CONFIDENTIAL
International Telecommunication Union - Telecommunication Standardization Sector Iu Interface InterWorking Function Local Area Network Low-level Signaling Transfer Point Mobile Application Part Man Machine Language MOdulator-DEModulator Mobile Station International ISDN Number Mobile Station Roaming Number Message Transfer Part Message Transfer Part Layer 2 Message Transfer Part Layer 3 Message transfer part (broadband) Reverse Address Resolution Protocol Remote Defect Indication Stream Control Transmission Protocol Service Data Function Synchronous Digital Hierarchy Software fault-oriented Group Unblocking message Temperature Control Unit Time Division Multiple Access Tandem Free Operation Temporary Mobile Subscriber Identifier Telephone User Part Unrestricted Digital Information User Datagram Protocol User Equipment Uplink Universal mobile telecommunication services/Universal Mobile Telecommunications System;
Page 64 of 65
GSM-R 3.2 GTSOFTX3000 Configuration Manual Abbreviation UPWR USSD UTRAN VDB VIEU VLR VMSC VPN WAD WCDMA WIN Full Spelling UMSC PSM PoWeR module Unstructured Supplementary Service Data UMTS Terrestrial Radio Access Network VLR Database Versatile Interface Extend Unit Visitor Location Register Visited Mobile Switching Center , Visited MSC Virtual Private Network Wireless Advertisement; Wide(band) Code Division Multiple Access Wireless Intelligent Network
CONFIDENTIAL
Page 65 of 65