You are on page 1of 3

1 GRADES OF STEEL AND CONCRETE = 415 25 N/Sq.

mm f =
2 FACTORED LOAD AND MOMENT ON COLUMN =(Pu)= 437.669 kN Mux= -17.543
DEPTH OF FOUNDATION = 2 m 1.5432
UNIT WEIGHT OF SOIL = 18 kN/cum
UNIT WEIGHT OF CONCRETE = 25 kN/cum
WEIGHT OF FOOTING = 1.44 0.4225 8.703125 KN
WEIGHT OF PEDESTAL = 8.60625 KN
WEIGHT OF BACKFILL = 39.37725 KN
TOTAL DESIGN LOAD = 494.355625 kN
3 SAFE BEARING CAPACITY OF SOIL = (Q)= 250 kN/sq.m
4 REQUIRED SIZE OF FOOTING = Sqrt(Pu/(1.5*Q)) = 1.1806 m
5 PROVIDE A FOOTING OF SIDE = (B) 1.20 m Qnet= 156.537
Max.Base Pressure = Pmax 195.90 kN/sq.m< 250.000
Min Base Pressure = Pmin 288.08 kN/sq.m
6 PEDESTAL SIZE =(b) 450 mm 0.45
7 B.M AT FACE OF THE PEDESTAL (M)=1.5*Qnet*(2*B+b)(B-b)
2
/24 15.684 kNm 19.8116602
8 EFFECTIVE DEPTH OF FOOTING REQUIRED = deff = 100.512 mm
9 OVERALL DEPTH PROVIDED
AT FACE OF PEDESTAL= D = 300 mm 0.3
AT END OF FOOTING = d = 150 mm 0.15
10 ONE WAY SHEAR =Vo= 1.5*Qnet*(0.5*(B-b)-(D-55)) 30.525 kN/m
11 TWO WAY SHEAR = Vt = 1.5*Qnet*(B
2
-(b+D-55)
2
) 224.702 kN
12 EFFECTIVE DEPTH OF FOOTING REQUIRED FROM
ONE WAY SHEAR CONSIDERATION= Vo/(tc*b) 65.504 mm 245
13 EFFECTIVE DEPTH OF FOOTING REQUIRED FROM
FROM TWO WAY SHEAR CONSIDERATION = Vt/(4*(b+D-55)*0.25*sqrt(fck)) 64.663 mm
14 EFFECTIVE DEPTH OF FOOTING AVAILABLE AT d FROM FACE OF PEDESTAL = 147.000 mm
EFFECTIVE DEPTH OF FOOTING AVAILBLE AT d/2 FROM FACE OF PEDESTAL = 196.000 mm
SAFE IN TWOWAY SHEAR WITHOUT SHEAR REINFORCEMENT
SAFE IN ONEWAY SHEAR WITHOUT SHEAR REINFORCEMENT
15 M/bd2 0.733
16 PERCENTAGE OF STEEL 0.2105 24.8735903
17 AREA OF STEEL= 232.121953 Sq.mm
18 NO.OF #10 DIA BARS REQUIRED = 4
NO.OF #10 DIA TO BE PROVIDED = 10 785.0 0.44501134
NO OF #12 DIA BARS REQUIRED = 3
NO.OF #12 DIA BARS BE PROVIDED = 10 1130 0.64058957
DIAMETER OF BARS PROVIDED = 10
450
150 300
1200.00
ALL DIMENSIONS ARE IN MM
DESIGN OF ISOLATED SQUARE FOOTING(SLOPING) F1
1200
19 NOMINAL SHEAR STRESS DUE TO ONE WAY SHEAR = 0.208 N/Sq.mm 6.52288464
20 PERMISSIBLE SHEAR STRESS = 0.466 N/Sq.mm
SAFE IN ONE WAY SHEAR CONSIDERING THE Ast PROVIDED
21 DEVELOPMENT LENGTH REQUIRED FOR 10MM BARS = 470 mm
22 DEVELOPMENT LENGTH REQUIRED FOR 12MM BARS = 564 mm
23 DEVELOPMENT LENGTH AVAILABLE= 375 mm
UNSAFE IN DEVELOPMENT LENGTH CONSIDERATION
24 BENT LENGTH REQUIRED FOR 10mm DIA BARS= 150 mm 95
BENT LENGTH REQUIRED FOR 12mm DIA BARS= 150 mm 189
30
kN m Muz= -2.367 kN m
kN/sq.m
kN/sq.m
m
kNm
m
m
mm
SAFE
UNSAFE
DESIGN OF ISOLATED SQUARE FOOTING(SLOPING) F1