Professional Documents
Culture Documents
Product Catalogues
MANUFACTURER /
SUPPLIER
APPLICATION
Schneider Electric,
Sweden
SPU 1201
Schneider Electric,
Sweden
DS 03
SPD 310
Schneider Electric,
Sweden
DS 04
MD20B-230
Schneider Electric,
Sweden
DS 05
MD10A-24
Schneider Electric,
Sweden
DS 06
MN-S4-FCS
Schneider Electric,
USA
DS 07
EE07-PFT1
EE244-AA1
EE242-A3
E+E, Austria
DS 08
CI-24
Legrand, France
DS 09
UI-500
DS 10
EPW105
DS 11
VER-HWL2XCX
S. NO.
DS 01
DS 02
ITEM DESCRIPTION
Page 1 of 4
Sontay, UK
Schneider Electric,
USA
Veris, USA
MANUFACTURER /
SUPPLIER
APPLICATION
Veris, USA
TFEYR00
Veris, USA
DS 14
TIWB1Y0
Veris, USA
DS 15
TE500DCW12H31E2
DS 16
TWLY00
DS 17
VER-HD2XVCX
DS 18
CLRSXX
DS 19
VER-CWE
DS 20
FSR1AK1X + FST4A020
DS 21
DS 22
S. NO.
DS 12
VER-HO2XMCX
DS 13
ITEM DESCRIPTION
Greystone, Canada
Veris, USA
Schneider Electric,
USA
Veris, USA
Schneider Electric,
USA
Veris, USA
VER-U001-0022
Veris, USA
TOYR00
Veris, USA
Page 2 of 4
MANUFACTURER /
SUPPLIER
APPLICATION
Greystone, Canada
CO Sensor
VCP, Sweden
HC2-IP25
Rotronic, USA
DS 26
LOXONE
Loxone, Austria
Light Sensor
DS 27
LL15
DS 28
AFS-262-HT
DS 29
GTC116-PB
Ebtron, USA
DS 30
D6200N+SY3-24-3-T
Belimo, Switzerland
DS 31
Axio, UK
DS 32
MNB-300
Schneider Electric,
USA
DS 33
SXWAUTSVR10001
Network Controller
Schneider Electric,
Sweden
DS 34
SXWPS24VX10001
Power Supply
Schneider Electric,
Sweden
S. NO.
ITEM DESCRIPTION
DS 23
WPS-G-PS3
DS 24
CMD 050VC
DS 25
Page 3 of 4
Schneider Electric,
Sweden
SXWSWESXX00001
Schneider Electric,
Sweden
BMS Software
DS 37
HP DX2XXX Series
HP China/Taiwan
Workstation PC
DS 38
Epson China/Taiwan
Printer
DS 39
Report Printer
HP China/Taiwan
Printer
DS 40
HP Probook Series
Laptop
HP China/Taiwan
Engineering Laptop
DS 41
Kamstrup + Sitrans
Sitrans, Germany
Kamstrup, Denmark
DS 42
Kamstrup
Sitrans, Germany
Kamstrup, Denmark
BTU Meter
DS 35
SXW - SERIES
DS 36
ATT 43
ATT 44
ATT 45
ATT 46
ATT 47
Page 4 of 4
SPD910
Differential Air Pressure Switch
This range of four SPD910 differential air flow
switches are intended for use in air handling systems
for the monitoring of air ducts, filters and fans.
The enclosure is plastic with a rating of IP54.
A set-point adjustment is provided under the
clip-on clear plastic cover.
The mounting bracket and tubing is supplied.
Description
Medium
Pressure Range
Tolerable overload on one side
Repeatability
0.2 3 mbar
0.5 5 mbar
1 10 mbar
5 20 mbar
10 50 mbar
Resistive Load
0.025 mbar
0.05 mbar
0.05 mbar
0.05 mbar
0.15 mbar
Switching Load
5 A at 250 Vac
4 A at 30 Vdc
Inductive
0.8 A at 250 Vac
0.7 A at 30 Vdc
Materials in contact with the medium
Case: PC 10% GF
Cover: PC
Diaphragm: Silicone LSR
tempered 200 C, free of gas emissions
Temperature
Medium and ambiance 30 +85 C -22.. +185F
Storage
Without Cover
With Cover
IP 00
IP 54
Service life
Electrical connection
Protection standard
Pressure connections
Pipe 6.2 mm
Adapter inside thread G1/8
Tests / Admissions
ETL
CE conformity
DVGW according to DIN 1854
EU conformity:
Low voltage directive 73/23/EWG
Gas appliance directive:
90/396/EWG CE 0085 A P0918
Model Number
Description
Replaces
004701090
SPD910-2000Pa
004701080
SPD910-1000Pa
004701070
SPD910-500Pa
SPD900-600Pa
004701060
SPD910-300Pa
SPD900-200Pa
Dimensions
INSTALLATION
Fig. 1
1)
Fig. 2
Flow area
Function
The pressure switch has two separate pressure
chambers, each with its own connection. The
switch operates when the setpoint is either
exceeded or not reached.
Vacuum Monitoring
Connect the pressure switch via P2. Do not
connect P1. Leave P1 open. Pake sure that dirt
can not get into P1.
www.schneider-electric.com
October 2011
SPU 1201
DS 21.602
02/03
TM
SPU
SPECIFICATION
Type:
34 bar
SPU 1201
Pressure Range:
0.2 to 4 bar
Reset Differential:
12 to 250 mbar
Reset Differential:
7 mbar approx.
5A at 250Vac (Resistive)
2A at 440Vac (Resistive)
Earth Connection Provided
10C to +80C
CONSTRUCTIONS
Diaphragm:
Beryllium Copper
Seals:
Nitrile Rubber
Pressure Chambers:
Brass
Pressure Connections:
Microswitch Housing:
Zinc Diecast
Top Cover:
Mounting Bracket:
Degree of Protection:
IP65
Terminals:
Cable Entry:
20mm conduit thread adaptor supplied. SPU thread also suitable for a cable gland nut.
Pressure Medium:
INSTALLATION
Fig.1
Dimensions in mm
WIRING
Normally Open Contact
Common Contact
Fig.2
ADJUSTMENT
INCREASE
Adjusting Nut
Operating
Pressure
Adjustment
DECREASE
Fig.3
Conduit
Thread
DIMENSION DRAWINGS
Adjusting
Nut
Low
Low
SPU1201
SPU1202
Dimensions in mm
High
High
Weight:
1.4kg (SPU 1201)
1.8kg (SPU 1202)
Type
SPU 1201
100
38
92
17.0
18.6
53.2
" BSP
77
21.4
14.5
SPU 1202
92.4
42.9
100
17.0
18.6
52.6
/8" BSP
90
16.2
12.5
TM
SPD 310
01
SPD310/SPD360
Part Number
Part Number
Product
004700320
SPD310-100/300/500/1000 Pa
004700340
SPD310-1000/1200/2500/5000
Pa
004700360
SPD360-300/500/1000/2500 Pa
Product specifications
Signal Output . . . . . . . . . . . . . . . . . . . . 0 - 10 VDC
Power.. . . . . . . . . . . . . 24 VAC 10%/15 - 32 VDC
Load Resistance. . . . . . . . . . . . . . . . . . >50 kOhm
Current Consumtion. . . . . . . . . . . . . . . . . . 10 mA
Accuracy (linear output). . . . . . . . . . . . 0.75%FS
0 - 100 Pa . . . . . . . . . . . . . . . . . . . . . . . . 1.5%FS
Linearity inc. temperature and
hysteresis . . . . . . . . . . . . . . . . . . . . . . . . . 2%FS
0 - 100 Pa.. . . . . . . . . . . . . . . . . . . . . . . . . 4%FS
Accuracy at ambient temp.
of 25 C/UG - 24V. . . . . . . . . . . . . . . . . 0.4%FS
Ambient Temperature
Materials:
Housing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PP
Duct Connections. . . . . . . . . . . . . . . . . . . . . . ABS
Tubing. . . . . . . . . . . . . . . . . . . . . . . . . . . PVC, soft
Enclosure Rating . . . . . . . . . . . . . . . . . . . . . . IP65
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 g
EMC Standards . . . . . EN 50081-1, EN 50082-12
Max. Pressure
100/300/500/1000 Pa . . . . . . . . . . . . . 10,000 Pa
1000/1200/2500/5000 Pa . . . . . . . . . . 50,000 Pa
dimensions
85
G0
1000 100Pa
1200
300Pa
2500
500Pa
5000 1000Pa
1
mbar
psi
Wiring details
30
sym.
Schneider Electric Telephone Europe: Malm, Sweden +46 40 38 68 50 Telephone Asia Pacific: Singapore +65 6776 3166 www.schneider-electric.com
03-00266-01-en
January 2012
MDB 20B-230
01
MD20B-24/-230
On/Off or 3-point 24 V AC/230 V AC
Damper Actuator 20 Nm (180 in-lb)
MD20B series damper actuators for operating air
control dampers in ventilation and air-conditioning
systems for building services installations
For air control dampers up to approx. 4 m2
(4.8 yard2 )
Torque 20 Nm (180 in-lb)
Nominal voltage AC/DC 24 V or 230 V
Control: On/Off or 3-point
Power consumption
In operation
MD20B-24. . . . . . . . . . . . . . . 2 W @ nominal torque
MD20B-230. . . . . . . . . . . . 2.5 W @ nominal torque
At rest
MD20B-24. . . . . . . . . . . . . . . . . . . . . . . . . . . 0.2 W
MD20B-230. . . . . . . . . . . . . . . . . . . . . . . . . . 0.6 W
For wire sizing
MD20B-24 . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 VA
MD20B-230. . . . . . . . . . . . . . . . . . . . . . . . . . . 6 VA
Connection cable. . . . . . . . 1 m (3.3 ft), 30.75 mm2
(AWG 18)
Angle of rotation. . . . . . . . . . . . . . . . . . . . . max. 95
(adjustable by mechanical stops)
Torque . . . min. 20 Nm (180 in-lb) @ nominal voltage
Running time . . . . . . . . . . . . . . . . . . . . . . . . . 150 s
Direction of rotation . . . . . . . . Reversible with switch
Position indication . . . . . . . . . . . . . . . . . mechanical
Standards conformity
EMC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2004/108/EC
LVD . . . . . . . . . . . . . . . . . . 2006/95/EC (230 V only)
Protection class
MD20B-24. . . . . . . . . . . III Safety extra-low voltage
MD20B-230. . . . . . . . . . . . . . . . . II Totally insulated
Weight
MD20B-24. . . . . . . . . . . . . . . . Approx 1 kg (2.2 lb.)
MD20B-230. . . . . . . . . . . . . . . Approx 1 kg (2.2 lb.)
DIMENSIONS mm (in)
64
(2,5)
Power supply
MD20B-24. . . . . . . . . . . 24 V AC 20%, 5060 Hz,
24 V DC 20%
MD20B-230. . . 230 V AC 56% to +15%, 5060 Hz
Ambient temperature
Operation. . . . . . . . . 30 to +50 C (22 to +122 F)
Storage . . . . . . . . . . 40 to +80 C (40 to +176 F)
Sound power leve. . . . . . . . . . . . . . . max. 45 dB (A)
Maintenance. . . . . . . . . . . . . . . . . Maintenance-free
56
(2,2)
Part numbers
MD20B-230. . . . . . . . . . . . . . . . . . . 875-1021-000
MD20B-24. . . . . . . . . . . . . . . . . . . . 875-1025-000
Enclosure rating. . . . . . . . . . . . . . . . . . . . . . . . IP 54
Ambient humidity. . . . . . . . . . 95% r.H (EN 60730-1)
139
(5,4)
88
(3,4)
SPECIFICATIONS
30
(1,2)
109
(4,3)
41
(1,6)
Length mm (in.)
Clamp on top
min. 48 (1.89)
Clamp on bottom
min. 20 (0.78)
mm
02
WIRING
0
1
Direction of rotation
On/Off control
G0
G
Manual override
Manual operation is possible with the selfresetting pushbutton (the gearing latch remains
disengaged as long as the pushbutton is pressed
or detented).
0
1
0
1
3-point control
N
L1
On/Off control
N
L1
SAFETY NOTES
3-point control
G0
G
0
1
0
1
WIRING
MD20B-230
Caution: 230 V voltage!
MD20B-24
Connection via safety isolating
transformer.
ACCESSORIES
Please refer to data sheet G-30-90
Accessories Damper Actuators
(part. no. 0-003-2251).
On October 1st, 2009, TAC became the Buildings Business of its parent company Schneider Electric. This document reflects the visual identity of Schneider Electric,
however there remains references to TAC as a corporate brand in the body copy. As each document is updated, the body copy will be changed to reflect appropriate
corporate brand changes.
Schneider Electric Telephone Europe: Malm, Sweden +46 40 38 68 50 Telephone Asia Pacific: Singapore +65 6776 3166 www.schneider-electric.com/buildings
003-0737-6
April 2010 ao
MD10A-24
01
MD10A-24
Modulating Damper Actuator Damper
Actuator 10 Nm (90 in-lb)
MD10A-24 damper actuators for operating air
control dampers in ventilation and air-conditioning
systems for building services installations
For air control dampers up to approx. 2 m2
(2.4 yard2)
Torque 10 Nm (90 in-lb)
Nominal voltage AC/DC 24 V
Control: Modulating 0 10 V
SPECIFICATIONS
Ambient temperature
Operation. . . . . . . . . 30 to +50 C (22 to +122 F)
Storage . . . . . . . . . . 40 to +80 C (40 to +176 F)
Sound power level. . . . . . . . . . . . . . max. 35 dB (A)
Maintenance. . . . . . . . . . . . . . . . . Maintenance-free
Standards conformity
EMC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2004/108/EC
LVD . . . . . . . . . . . . . . . . . . 2006/95/EC (230 V only)
Protection class. . . . . . . III Safety extra-low voltage
Enclosure rating. . . . . . . . . . . . . . . . . . . . . . . . IP 54
62
(2.4)
52
(2.05)
DIMENSIONS mm (in)
124
(4.9)
80
(3.1)
Power consumption
In operation . . . . . . . . . . . . . . 2 W @ nominal torque
At rest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.4 W
For wire sizing. . . . . . . . . . . . . . . . . . . . . . . . . . 4 VA
Connection cable. . . . . . . . 1 m (3.3 ft), 40.75 mm2
(AWG 18)
Control signal X . . . . . . . . . . . . . . . . . . . 010 V DC
Input resistance . . . . . . . . . . . . . . . . . . . 100 k Ohm
Operating range. . . . . . . . . . . . . . . . . . . 210 V DC
(for set angle of rotation)
Synchronisation tolerance. . . . . . . . . . . . . . . . . 5%
Position feedback Y. . . . . . 210 V DC (max. 1 mA)
Direction of rotation . . . . Reversible with switch 0 / 1
at switch position 0
resp. 1
Angle of rotation. . . . . . . . . . . . . . . . . . . . . max. 95
(adjustable by mechanical stops)
Torque . . . . min. 10 Nm (90 in-lb) @ nominal voltage
Running time . . . . . . . . . . . . . . . . . . . . . . . . . 150 s
Position indication . . . . . . . . . . . . . . . . . mechanical
Manual override. . . . . . . . Gearing latch disengaged
. with pushbutton, self-resetting, manual locking
25
(1.0)
99
(3.9)
41
(1.6)
Length mm (in.)
Clamp on top
min. 40 (1.57)
Clamp on bottom*
min. 20 (0.78)
mm
02
WIRING
SAFETY NOTES
WIRING
ACCESSORIES
Please refer to data sheet G-30-90
On October 1st, 2009, TAC became the Buildings Business of its parent company Schneider Electric. This document reflects the visual identity of Schneider Electric,
however there remains references to TAC as a corporate brand in the body copy. As each document is updated, the body copy will be changed to reflect appropriate
corporate brand changes.
Schneider Electric Telephone Europe: Malm, Sweden +46 40 38 68 50 Telephone Asia Pacific: Singapore +65 6776 3166 www.schneider-electric.com/buildings
003-2232-5
April 2010
ao
MN-S4-FCS
MicroNet Sensors
MCS-4000
The TAC I/A Series MicroNet Sensors (MNSxxx
series) are a family of digital wall temperature
and humidity sensors for use with TAC I/A Series
MicroNet controllers. These sensors feature a Sensor
Link (S-Link) communication protocol which provides
a simple two-wire interface for power and exchange
of sensor and subbase information. Subbase
information includes selecting occupancy override,
fan speed, operating mode, or emergency heat.
Continued on next page.
SPECIFICATIONS
Temperature Sensor
Ambient Limits
Type
Precision thermistor.
Operating Temperature
32 to 122 F (0 to 50 C).
Range
32 to 122 F (0 to 50 C).
Humidity Sensor
Humidity
5 to 95% RH, non-condensing.
Element
Type: . . . . . . . Thermoset polymer capacitive sensor.
Accuracy:. . . . . . . . . . . . . . 2% RH at 77 F (25 C).
Range
5 to 95%, non-condensing.
Hysteresis
1.2% RH maximum.
Immersion
Extended exposure to equal to or greater than
90% RH causes a reversible 3% shift. Sensor will
recover from short term exposure to liquid water or
condensation. Repeated exposure will degrade the
performance of the sensor.
Dimensions
4-21/32 H x 3 W x 1 D in (118.5 x 76.2 x 24 mm).
Enclosure
Conforms to NEMA-1 requirements.
Surge Immunity Compliance
IEEE C62.41 (IEEE-587, Category A & B).
Hardware
Wiring Terminals
Four (4) screw terminals. AWG #18 to #24
(0.823 mm2 maximum) wire.
Display
Setpoints, input spans, and units vary with the
controller application.
Range
-99 to 999 or -9.9 to 99.9.
Units
F, C, or %.
Command Options (S4xx and S5xx Models)
Varies with the controller application.
System Mode
Heat/Cool/Off/Auto (except MN-S4xx-FCS).
Fan Mode
Off/On/Speed (Low, Medium, High)/Auto.
Agency Listings
Override
Occupied/Unoccupied (except MN-S4xx-FCS).
FCC
Class B.
Emergency Heat
Enable/Disable (MN-S5xx models only).
UL Listed
UL-916 (File # E71385 Category PAZX).
UL Listed to Canadian Safety Standards (CAN/CSA
C22.2).
MicroNet Sensors
FEATURES
SOFTWARE SPECIFICATIONS
Digital Display (MN-S3xx, MN-S4xx and
MN-S5xx Models only)
Custom field-configurable sensor displays.
Auto-ranging of displayed values.
Occupant command capabilities.
Adjustable minimum/maximum limit setpoint values.
Controller driven, automatically configured,
customized display/command values.
Typical MN-S3xx, -S4xx, or -S5xx Display/Change Values.
Value
Display
Change
Zone Temperature
Yes
No
S4xx, S5xx
Yes
No
S4xx, S5xx
Percent Humidity
Yes
No
Yes
Yes
S4xx, S5xx
Mode Heating/Cooling/Auto/Off
Yes
Yesb
S4xx, S5xx
Yes
Yes
Model Family
Schneider Electric
F-26290-10
1354 Clifford Avenue, P.O. Box 2940, Loves Park, IL 61132-2940, USA
1-888-444-1311
www.schneider-electric.com/buildings
November 2009
tl
MicroNet Sensors
Communications
S-Link
Sensor Link (S-Link) communications wiring provides
power and communication interface to the
TAC I/A Series MicroNet sensor (MN-Sxxx series). It
uses two-wire, unshielded cable and is not polarity
sensitive. From some sensor models, the user can
view and adjust application parameters. Maximum
wire length allowed between a controller and the
TAC I/A Series MicroNet sensor is 200 ft. (61 m).
BACnet or LonWorks Network
The BACnet or LonWorks network wiring can
be connected to the second set of terminals in
the sensor base. This optional connection allows
convenient access to the LonWorks network at the
sensor.
MODELS
Model
Description
Keypad
Display
Temperature
Sensor
Temperature
and Humidity
Sensor
MN-S1
MN-S1HT
Sensor only
None
None
MN-S2
MN-S2HT
One button
MN-S3b
MN-S3HTb
Three button
MN-S4b
MN-S4HTb
Six-button
MN-S4-FCSb
MN-S4HTFCSb
Six button
MN-S5b
MN-S5HTb
Seven button
Schneider Electric
F-26290-10
1354 Clifford Avenue, P.O. Box 2940, Loves Park, IL 61132-2940, USA
1-888-444-1311
www.schneider-electric.com/buildings
November 2009
tl
MicroNet Sensors
Architecture
PDA
MicroNet Sensor
(MN-S5 Shown)
MN 110 or MN 130
Controller
MNL-V3RVx
or MN 50
Controller
DO5
C5
934G
E9429
DO1
24VAC
DO2
DO3
24VAC
DO4
N2223
CAUTION
This device conforms with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) This device must accept any interference received, including interference that
may cause undesired operation.
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet
appareil numerique de la classe B respecte toutes les exigences du Reglement sur le material brouilleur du Canada
T
X
M
I
J1
I/A Series
MNL-11RF2
GND
0V
24VAC
UI3
COM 0V
UI2
COM 0V
UI1
S-LK
S-LK
LON
LON
SRVC
S
R
R
E
C
V
V
C
SW
24H
SW 3
24H
2
24H
24H 1
MNL-CIM
MicroNet Controller
Interface Module
SW
24G
GN
AO
UI
K/C DI
OM
S-L
K
LON
LON
S-L
Router 6
(if required)
LONWORKS
Network
I/A
MN
MN 100, MN 150, or
MN 200 Controller
UNC Controller
MNL-V1RVx
or MNL-V2RVx
Controller
Se
rie
80
MN 800
Controller
4
MicroNet Sensor
(MN-S3 Shown)
A PC can be connected to the LONWORKS TP/FT-10 Network, either directly or through the LONWORKS network jack of a LONWORKS
controller or MN-Sxxx Wall Sensor. The PC must have an Echelon LONTALK adapter card.
Programming any of the TAC I/A Series controllers, or the TAC I/A Series MN 800 controller, requires WorkPlace Tech Tool.
This controller is not suitable for exposed mounting on a wall or panel, or in any other easily accessible place due to the possibility of
personal contact with the high-voltage terminals. It must be mounted inside a suitable grounded metal enclosure.
A PDA running the Pocket I/A interface software may be used to communicate with TAC MicroNet I/A Series controllers.
When routers are used, WorkPlace Tech is able to communicate through them to any of the TAC I/A Series devices on the network.
UNC Universal
Network Controller
or
ENC Enterprise
Network Controller
S-Link
Sensor
S-Link
Sensor
S-Link
Sensor
S-Link
Sensor
S-Link
Sensor
MicroNet BACnet
MNB-300
Unitary Controller
MicroNet BACnet
MNB-70
Zone Controller
MicroNet BACnet
MNB-V1
Cooling Controller
MicroNet BACnet
MNB-V2
Deluxe Controller
On October 1st, 2009, TAC became the Buildings Business of its parent company Schneider Electric. This document reflects the visual identity of Schneider Electric, however there
remains references to TAC as a corporate brand in the body copy. As each document is updated, the body copy will be changed to reflect appropriate corporate brand changes.
All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice.
All rights reserved.
Schneider Electric
F-26290-10
1354 Clifford Avenue, P.O. Box 2940, Loves Park, IL 61132-2940, USA
1-888-444-1311
www.schneider-electric.com/buildings
November 2009
tl
Desktop PC or Notebook PC
with WorkPlace Tech Tool Software
EE Series
EE240 Series
EE245 Transmitter
EE244 Transmitter
EE241
Base Station
EE242
Router EE244-R
v1.5
EE240
Typical Applications
Features
Pharmaceutical Industry
Warehouses
Control Rooms
Cooling Chambers
Museums
HVAC Systems
Food Industry
The integrated Webserver allows platform-independent installation, remote access and easy
maintenance with any commercially available browser (Internet Explorer, Firefox, OPERA...) on a computer
without additional software.
Wireless Networks
EE241 (point-to-point connection)
Transmitter
(max. 500 pieces)
Transmitter
(max. 1 piece)
Router
(max. 60 pieces)
)
1
Base Station
max. 10 radio signals each node
1) Radio ranges:
- up to 60m (197 ft) indoors
2) Radio ranges:
- up to 100m (330 ft) indoors
- up to 1000m (3300 ft) in open field
Base Station
Comparison
EE241
EE242
Transmitter:
max. number of transmitters EE244 / EE245
500
Router:
maximum number of routers EE244-R
60
60
Base Station:
configuration of analogue outputs
user-configurable after delivery
digital interface
EE240
via Webserver
via Webserver
Ethernet, Modbus
133
Transmission frequency
Transmission system
Transmission power
Radio range
Approval
Electromagnetic compatibility
2.4 GHz
IEEE 802.15.4
10mW
up to 100m (330 ft) indoors, up to 1000m (3300 ft) in open field
ETSI / FCC Part 15.247 / IC
EN61326-1 Industry
FCC Part 15 Class B
EN61326-2-3 Industry
ICES-003 Class B
EE245 (Transmitter)
Power Supply
battery 4x1.5V AA
Battery lifetime
> 1 year with a measuring data transmission every 5 min. (for T / %RH)
Radio Range
up to 60m (197 ft) indoors
Antenna
internal
External supply transmitter (EE245)
DC 8-28V SELV / AC 12V (20%)
Housing material
polycarbonate (PC)
Protection class housing
IP30
Temperature ranges
working temperature range: 0...90%RH (non-condensing) / -5...+55C (23...131F)
storage temperature range: 0...90%RH (non-condensing) / -5...+55C (23...131F)
Max. numbers of measuring values
3 (T / RH / CO2**)
Accuracy
T: 0,3 C (at 20 C) / 0,4 C (20...55 C)
Rh: 3 % (30...70 %) / 5 % (70...90 %)
CO2: 2000ppm ( 50ppm +2 % of m.v.)
5000ppm ( 50ppm +3 % of m.v.)
Connection
screw terminal 1,5mm
*) with external power supply
Dimensions in mm
EE244-Ax3:
EE244-Bx2:
EE245
32
31
85
110
90
(3.5)
136
20
(0.9)
(4.3)
11,5
135
10 9
(2)
GND
VCC
depth: 50
(5.3)
134
power supply
DC 8-28V SELV
AC 12V (20%)
EE240
Supply voltage SELV
digital interface
Current consumption EE241
EE242
Analogue outputs
Number of analogue outputs
Accuracy of analogue outputs
Temperature dependence
of analogue outputs
Resolution of analogue outputs
Electrical connection
Housing material
Protection class housing
Temperature ranges
108
(4.3)
(0.2)
11
(0.4)
62
24V AC/DC
RS485
SELV
Modbus RTU
V/
mA
12
13
14
V/
mA
V/
mA
15
16
GND
11
GND
10
OUT4
GND
GND
OUT3
NC
NC
GND
OUT2
OUT1
NC
V+
90
(3.5)
11
(0.4)
GND
V/
mA
(2.4)
Accuracy
Order Code
Humidity/Temperature Probes
RH/T probe for standard applications
0...100% RH
-40...80C (-40...176F)
2% RH (0...90% RH)
EE07-PFT1
3% RH (90...100% RH)
0.1C (0.18F) at 20C (68F)
2% RH (0...90% RH)
3% RH (90...100% RH)
0.1C (0.18F) at 20C (68F)
EE07-MFT9
3% RH (10...100% RH)
at 21C (69.8F)
0.3C (0.54F) at 20C (68F)
EE03-FT9
Temperature Probes
T probe for standard applications
-40...80C (-40...176F)
-40...80C (-40...176F)
02000ppm
05000ppm
010000ppm
(50ppm+2% of m.v.)
(50ppm+3% of m.v.)
(100ppm+5% of m.v.)
CO2 Probes
CO2 probe for standard applications
EE240
EE871
135
Ordering Guide
Base station - point-to-point connection (EE241) and wireless network (EE242)
EE241-
EE242-
A
2
3
5
6
D
-
A
2
3
5
6
D
-
Hardware Configuration
Frequency
Output signal
2,4GHz (10mW)
0-5V
0-10V
0-20mA
4-20mA
with
without
Display
Software Configuration
Physical parameters of relative humidity
temperature
outputs
Unit
T-Scaling (in C or F)
Td-Scaling (in C or F)
CO2-Scaling (in ppm)
RH
T
Td
CO2
[%]
[C]
[C]
[ppm]
(A)
(B)
(C)
(R)
0...50
(T04)
furhter scalings on request
0...10.000 (C22)
output
output
output
output
1
2
3
4
output T
output Td
A
B
C
R
E01
Select Txx code
Select Tdxx code
/C/R
/C/R
/C/R
/C/R
E01
Select Txx code
Select Tdxx code
TRANSMITTER EE245
Type
CO2
Frequency
Display
A/
A/
A/
A/
B
B
B
B
EE245FTC
FTx
xTC
xTx
2
5
x
A
D
x
RH + T + CO2
RH + T
CO2 +T
T
0...2000ppm
0...5000ppm
without CO2 measurement
2,4GHz (10mW)
with
without
Software Configuration
Unit
E01
C
F
transmitter
transmitter with external supply
router
2,4GHz (10mW)
1
2
3 (not possible with type B - transmitter with external supply)
with
without
EE244A
B
A
1
2
3
D
-
EE244R
A
Temperature
probe T (polycarbonat)
probe T (metal)
CO2
probe CO2
136
EE07-PFT1
EE07-MFT9
EE03-FT9
EE07-PT1
EE07-MT
EE871
EE240
(HA010330)
(HA010333)
(V02)
Transmitter:
- Probe cable for EE07 -
2m (7ft) / 5m (16ft) / 10m (33ft)
- Connection cable for EE03, 2m (7ft)
- Connection cable for EE03, 5m (16ft)
- Antenna cable 2m (7ft)
- Bracket for rail installation
- Reference probes
- Duct mounting kit for EE07
- External power supply unit
EE244 EE245
(HA0108xx)
()
(HA010328)
(HA010329)
(HA010330)
(HA010203)
(HA010403)
(HA010209)
(V02)
()
()
()
()
()
()
()
()
Oder Example
1)
2)
Frequency: 2,4GHz
Output signal:
0-10V
Display: yes
Outputs:
RH, T, Td, CO2
Unit:
SI
Scaling:
T: 0...50; Td: -20...50
Type:
Industral transmitter with
external supply
Frequency: 2,4GHz
Probe: 1
Display: yes
Position 2 - Transmitter:
EE245-FTC5Ax
Frequency: 2,4GHz
Output signal:
0-10V
Display: yes
Outputs:
RH, T, Td, CO2
Unit:
SI
Scaling:
T: 0...50; Td: -20...50
Type:
Room transmitter for relative
Humidity, Temperature and CO2
CO2: 0...5000ppm
Frequency: 2,4GHz
Display: without
EE240
137
CI-24
NEW!
LIGHTING CONTROLS
WattStopper Occupancy Sensor
CI-24
Description
The CI-24 is a ceiling-mount passive infrared occupancy
sensor specifically designed to interface with Building
Automation Systems through an internal isolated relay. A
user-adjustable time delay (30 seconds to 30 minutes) on
deactivation may be programmed through DIP switches to
prevent unnecessary cycling. The CI-24 includes a built-in
override switch. Two levels of sensitivity are also selectable
through DIP switches. The four-level patented Fresnel lens
allows the CI-24 to cover up to 1200 ft2 (111.48 m2).
Features
LIGHITING CONTROLS
12
CI-24
Supply Voltage
Contact Rating
Coverage Pattern
ORDERING INFORMATION
562
Wiring
Specifications
MODEL
CI-24
OPERATION
DESCRIPTION
Ceiling-mount occupancy sensor
with SPDT isolated contact
Isolated Relay
Contacts
24 VAC/VDC Supply
Cable
Wires
1-(red)
2-(green)
Common
3-(orange)
4-(yellow)
24 Return
5-(black)
LED
ON 1 2 3 4
DIP SWITCH #
TIME DELAYS
30 sec
10 min.
20 min.
} 30 min.
X
X
O
O
X
O
X
O
SENSITIVITY
} Minimum
Maximum
OVERRIDE
} Normal
Override
O
X
O
X
X=on
O=off
}= factory setting
Note: Exceeding voltage rating may damage sensor.
2012 Kele, Inc. All rights reserved. The Kele name and logo are registered trademarks of Kele, Inc.
August 2012
UI-500
UI-500
Date of Issue: 12/02/2013
Issue Number: 5.3
Page 1 of 1
UI-500
Custom Interface Options Individual Solutions
Overview
In addition to our standard range of sensors we are able to manufacture user interface equipment to your
specifications. Typically this would be a single or twin gang plate styled to match other equipment on a project.
The examples on this page are just a few of the types, designs and options we can supply.
Please contact the Customer Service Team for more information or to discuss your requirements.
Whilst every effort has been made to ensure the accuracy of this specification, Sontay cannot accept responsibility for damage, injury, loss or
expense from errors or omissions. In the interest of technical improvement, this specification may be altered without notice.
CUSTOMER DETAILS
22/07/2013
SP reference 3043
Date
Schneider Electric
Lloyed Thoppil
Customer
Contact
SUMMARY OF CUSTOMER REQUIREMENTS
1 Gang stainless steel plate fitted with a 0-10k potentiometer
0
0
0
0
DRAWING / LAYOUT DETAILS
AIRFLOW ADJUSTMENT
LESS AIR
MORE AIR
Signature:
Print Name:
Date:
In accordance with our standard terms and conditions these "special products" are non returnable unless
they are deemed by Sontay to be defective through no fault of the customer.
Telephone: +44 (0) 1732 816200
Email: sales@sontay.com
90800012 Issue 7
EPW105
Sensors
EPW Series
Differential Pressure Transducer Wet Media
Installer's Specifications
Quick Install
1. Affix the backplate to a mounting surface (wall, duct, sheet
metal, etc.).
2. Plumb the ports to "HI" and "LO" sides of the pressure
differential. Wrap the fitting with 2-3 turns of Teflon tape, hand
tighten, then use a wrench to make two more turns.
3. Wire the sensor. See the Wiring section on page 2 for details.
4. Configure the jumpers as desired. See the Configuration section
on page 3 for details.
Dimensions
2.3"
(57 mm)
5.8"
(147 mm)
LOW
HIGH
4.1"
(102 mm)
Sensors
EPW Series
Installation/Wiring
EPW
ZERO
Note: Use of
housing grounding
lug is required for CE
applications
Analog Reverse
JP8
JP7
JP6
JP3
JP2
JP1
Range
A
B
C
D
REMOTE ZERO
(Dry Contact)
Port Swap
Bidirectional
Fast
5V
mA
POWER
SIGNAL
POWER SUPPLY
12 to 30 VDC/24 VAC
/ Normal
/ Normal
/ Normal
RANGE
COM
MODEL
EPW103
EPW104
EPW105
DIGITAL CONTROL
Analog Input
0-5V/0-10V
or 4-20mA
Optional
Digital Output
A
50
100
250
B
25
50
125
C
10
20
50
D
5
10
25
EPW2
ZERO
A-High
B-Mid High
C-Mid Low
D-Low
Pressure
Range
Note: Use of
housing grounding
lug is required for CE
applications
POWER SOURCE
12 to 24 VDC
Voltage IN
DIGITAL CONTROL
Digital Output
Schneider Electric
F-27667-1
REMOTE
4-20mA ZERO
Settings
Port Swap/Norm
Bi-Dr/Normal
Slow Avg/Fast Norm
Analog Rev/Norm
Bar/PSI
Range psi
EPW2103
EPW2104
EPW2105
A
50
100
250
B
25
50
125
C
10
20
50
D
5
10
25
Range bar
EPW2103
EPW2104
EPW2105
A
3.45
6.89
17.24
B
1.72
3.45
8.62
C
0.69
1.38
3.45
D
0.34
0.69
1.72
1-888-444-1311
Polarity Insensitive
www.schneider-electric.com
October 2009 ao
Sensors
EPW Series
Configuration
Operation
EPW
GREEN ON (solid):
Normal
GREEN (blinking):
JP3: Slow or fast mode. Slow mode provides 5-second averaging for surge
dampening; fast mode provides 1-second averaging.
RED ON (solid):
RED (blinking):
JP6: Bidirectional or Normal. Normal mode range is from zero to full scale
differential pressure. Bi-directional mode changes range from minus full scale
to plus full scale differential pressure. Output will be at one half when the
differential pressure is zero (see table below).
ZERO
Press and hold the ZERO push-button for 2 seconds or provide contact closure on
auxiliary REMOTE ZERO terminal to automatically reset output to ZERO pressure.
JP7: Port Swap or Normal. This setting is used to remedy situations when the "HI" &
To protect the unit from accidental ZERO, this feature is enabled only when detected
"LO" ports to the pressure transducer are incorrectly plumbed. Use jumper JP7 to
pressure is within 5% of factory calibration.
reverse polarity of pressure ports. This jumper makes the "HI" port "LO" and the
"LO" port "HI".
JP8: Analog Reverse or Normal. Normal mode output increases as pressure
increases. Reverse mode output is maximum when pressure differential is zero
and decreases as pressure increases.
RANGE: Use range switch to select full-scale differential pressure.
Product Identification
Range
EPW
103 = 0-50psig
Blank = No Display
104 = 0-100psig
EPW2
105 = 0-250psig
Fast or Slow: Slow mode provides 5-second averaging for surge dampening; fast
mode provides 1-second averaging.
Range
Bidirectional or Normal: Normal mode range is from zero to full scale differential
pressure. Bi-directional mode changes range from minus full scale to plus full
scale differential pressure. Output will be at one half when the differential
pressure is zero (see table below).
Local Display
Local Display
EPW2
103 = 0-50psig
Blank = No Display
104 = 0-100psig
105 = 0-250psig
Port Swap: This setting is used to remedy situations when the "HI" & "LO" ports
to the pressure transducer are incorrectly plumbed. Use jumper "Port Swap" to
reverse polarity of pressure ports. This jumper makes the "HI" port "LO" and the Select operational range according to the max. gauge pressure, NOT differential pressure.
Example: For hi-gauge pressure = 90psig, select the 100psig model.
"LO" port "HI".
Analog Reverse or Normal: Normal mode output increases as pressure increases.
Reverse mode output is maximum when pressure differential is zero and
decreases as pressure increases.
Note: The EPW Series is 3-wire. The EPW2 Series is 2-wire, loop-powered.
Range: Use range switch to select full-scale differential pressure. Select psi or bar
by positioning jumper.
InputConditions(psi)
Result
OutputsRead
Hi Port
Lo Port
DP
4-20mA
100
+100
20
100
50
+50
16
50
50
12
50
100
-50
100
-100
Schneider Electric
F-27667-1
Bi-directional Operation
1-888-444-1311
www.schneider-electric.com
October 2009 ao
Sensors
EPW Series
Available Products
Part Number
Product Description
EPW103
EPW103-LCD
EPW104
EPW104-LCD
EPW105
EPW105-LCD
EPW2103
EPW2103-LCD
EPW2104
EPW2104-LCD
EPW2105
EPW2105-LCD
Notice:
This product is not intended for life or safety applications.
Do not install this product in hazardous or classified locations.
Read and understand the instructions before installing this product.
Turn off all power supplying equipment before working on it.
Schneider Electric
F-27667-1
1-888-444-1311
www.schneider-electric.com
October 2009 ao
VER-HWL2XCX
HUMIDITY
1% & 2% NIST, or STANDARD
2%, 3%, or 5%
9EAR