To design & fabrication of a hardware which will

monitor the performance of the load sharing process


by taking power consumed by the load into
consideration.
o The transformer cannot supply load more than its
rated capacity.

o So, by introducing another transformer, reduces the
load on the transformers.

o Two transformers are used - Main transformers &
Slave transformers.

o Here 2 transformers are connected through a relay.






Load is directly connected to secondary of the main
transformer as well as slave transformer.

A sensor circuit is used to log data from the main
transformer .

If sensor found the overvoltage condition, immediately
the slave transformer will be connected in parallel to
the main transformer & the load is shared.





Regulated Power supply
Transformers
LM324 Op-amp (As a comparator)
Load Bank
Relay
Transformers


o Transformer is a static device which consist of two or more
stationary electric circuit interlinked by a common magnetic circuit
for the purpose of transferring electrical energy between them.

o The transfer of energy from one circuit to another takes place
without change in frequency.

o In this project we are using 2 transformer- main & slave
transformers.

o Rating of both the transformers- 230/12v & 3A.









o Both transformers of same rating are connected in parallel through
a relay.




Regulated power supply-

o A regulated power supply is embedded circuit, the function of
which is to supply a stable voltage.

o The output is dc(direct current). This
regulated output is supplied to comparator IC.

o To make Regulated power supply we use-

- Diodes
-Capacitors(4700F&25v)
-IC 7805 voltage regulator.





oTransformer- steps down high voltage AC mains to low voltage
AC.

oRectifier - converts AC to DC, but the DC output is varying.

oFilter- smooths the DC from varying greatly to a small ripple.

oRegulator - eliminates ripple by setting DC output to a fixed
voltage.
Comparator-

LM324 operational amplifier is used as a comparator
in this project.

It is used to compare load with the standard load
capacity of a transformer.

When the load capacity exceeds the capacity of load
it give signal to relay to switch on the slave transformer
in parallel to the main transformer.
Relay-

o A relay is an electrically operated switch.

o Relays allow one circuit to switch a second circuit
which can be completely separate from the first.

o In this project we are using electromagnetic relay
consists of a multi-turn coil, wound on an iron core, to
form electromagnet. When the coil is energised, by
passing current through it, the core becomes
temporarily magnetised. The magnetised core attracts
the iron armature.
Load Bank-



o In this project we are using set bulbs as a load,
connected at the secondary of a transformers.

Transformer rating is= 12VX 3A
= 36 VA or watt
Load capacity(rating) = >36watt ~ 3- 10watt bulbs &
1- 2 watt
1. Automated load sharing of transformers.
2. Prevent transformer and system from destroying or
malfunctioning.
5. Low cost and reliable system
3. No manual error.
4. Highly sensitive.



3. Protection from overloading of transformers.
2. Process Industry.
1. Power generation & distribution system.
4. Uninterrupted power supply.