STAGE-I(60 MW)
3.
4.
5.
6.
VACUUM PULLING
(MS PR 45-50 KSC.,THROTTLE STEAM TEMP AROUND 300 DEG.)
- ENSURE THAT CT FANS ARE RUNNING,THEIR WATER LINES ARE
OPENED.CONDENSER CW LINES ARE OPENED.
-
WHEN DIFF BETWEEN THROTTLE STEAM & STEAM CHEST INNER IS LESS
THAN 70 DEG,NOTE DOWN TSI PARAMETERS,MS SILICA SHOULD BE LESS
THAN 0.02 PPM (CONFIRM THROUGH CHEMISTRY)
ROLL THE M/C TO 500 RPM BY GOVERNER.CHECK FOR ANY ABNORMAL
VIBRATION & TSI PARAMETERS.
SOAK FOR 5-10 MINUTES.
THEN ROLL THE M/C TO 1200 RPM.HERE WE HAVE TO STAY FOR AROUND 1
HR.
THEN INCREASE SPEED TO 3000 RPM.NOTE TSI PARAMETERS &
VIBRATIONS.AOP SHOULD TRIP AT 2850 RPM.OTHER WISE STOP IT
MANUALLY.
SYNCHRONISE THE UNIT WITH GRID WITH SYNCHRONOUS
SCOPE(MATCHING FREQUENCY,PHASE & VOLTAGE).INCREASE LOAD TO 5-6
MW TO AVOID LOW FORWARD POWER PROTECTION.
TAKE THE GOVERNER OUT.
PUT EXHAUST HOOD SPRAY LINE IN AUTO.D/L IN LOWER SIDE.
IN BETWEEN WE CAN CHARGE GT COOLERS,H2 COOLERS AFTER
SYNCHRONISATION.