You are on page 1of 1
Rehabilitation Works — CIS Criuleni & CIS Lopatna IEB #PPS/THVAP/W/CB/02 Millennium Challenge Account ~ Moldova 3.4.13. Hydrant Hydrants shall be Installed on tertiary pipelines every 50 m. First and last hydrant shall be installed as is Indicated in drawings. The hydrant shall consists of one riser as per clause 3.4.12 of Particular Technical Specifications equipped with one special hydrant valve as per clause 3.4.13 of Particular Technical Specifications. The hydrant riser shall be connected to the tertiary pipeline by special flanged HDPE T- plece as per clause 3.4.10 of Particular Technical Specifications. All components of hydrant shall be of ‘nominal pressure 10 bar (NP 10). The height of hydrant shall be sufficient to exceed the ground elevation by 50 cm and shall be equipped with a warning rod as indicated In drawing. Method of installation, materials fittings and connecting fasteners shall be approved by the Engineer before ordering. 3.4.14 Air valves Air release shall be of automatic float type designed to release accumulated alr in the water pipeline Under pressure and to allow alr entering Into pipelines for dewatering or in case of negative pressure. The dimensions and those specified In drawir releasing the air he valve shall provide water tightness for minimum pressure of 1 bar and maximum pressure of 10 bar.. The valve will be NP 10. Method of Installation, materials, fittings and connecting fasteners shall be approved by the Engineer before ordering. 3.4.15 Washout ‘The washout shall be installed on all pipelines to allow dewatering of pipeline for repair or before cold season, The location of washouts Is Indicated in the drawings. The stee! double flanged drain pipe shall bbe of DN 80, NP 10, For dewatering the pipe a mobite diesel pumping unit of 5.5 CP/3600 rpm, suction depth of minimum 4 m, discharge pressure of min 3 bar, equipped with flexible suction hose and mobile hand moving lateral for discharge the water over the irrigation area. The flexible suction hose shall be of 80 mm in diameter and shall have enough stiffness to maintain its original shape of cross section at Negative pressure up to 0.8 bar and enough flexibility to allow connection to the drain pipe of the washout. The discharge lateral shall be equipped with 10 sprinklers of Impact type of 0.8 /s each. The length of lateral shall be at least 120 m and shall have a minimum diameter of 80 mm. The material of hhand moving lateral shall be HDPE 80 or aluminum. Two brand new mobile diesel pumping units equipped as described above shall be procured and handed to WUA management for use during ‘operation for dewatering of the Irrigation network before cold season or for dewatering of any plpeline for repairing. Equipment, materials, fitings and connecting fasteners shall be approved by the Engineer before ordering. 3.5 VALVES 3.5.1 Valves~ general. EN Standards have generally been referred to in this Specification. Any other equivalent national or International standard may be used, subject to the Engineer's approval. All valves shall be best waterworks quality and shall be suitable for use with water or waterworks sludge at temperatures of up to 45° C. Valve bodies shall give the following information: © manufacturer's name + hydraulic test pressure © size of valve _ reaton Cf flow ‘arrow’ (where flow in only one direction is permitted). “The Operating gear of valves shall be such that one person can open and close the valve against an, “oy {unbalanced ead 15% in excess of the maximum likely to be encountered in service.” ‘ ‘te valves dal be provided with renewable seats. Gates shall be capable of being removalist XOX", femfoving the valve body from the pipework. i, “gf Ly an gee ae Section IX. Specifications ~ Particular CIS Cine Amen] Y Se 13, Meal. ‘fi

You might also like