You are on page 1of 1

Project 1

18.01.2010

Operator
Telephone
Fax
e-Mail

research room / Summary


14.20 m

500
500

500
700

500

700
700 500

700
700

700

500

700 600

600

700

700

700
700

500

500

500
0.00

0.00

5.97 m

Height of Room: 2.800 m, Mounting Height: 2.900 m, Light loss factor:


0.80
Surface
Workplane
Floor
Ceiling
Walls (4)

Values in Lux, Scale 1:183

r [%]

Eav [lx]

Emin [lx]

Emax [lx]

u0

/
20
80
50

586
541
108
218

302
288
76
84

763
682
121
384

0.51
0.53
0.70
/

Workplane:
UGR
LengthwaysAcross
to luminaire axis
Height:
0.760 m
Left Wall
14
15
Grid:
64 x 32 Points
Lower Wall
14
15
Boundary Zone:
0.000 m
(CIE, SHR = 0.25.)
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.362, Ceiling / Working Plane: 0.184.
Luminaire Parts List
No.

Pieces

18

Designation (Correction Factor)


Philips IMPALA TBS160 C6 4xTL-D18W/830 (1.000)
Total:

F [lm]

P [W]

5400

70.0

97200

1260.0

Specific connected load: 14.85 W/m = 2.53 W/m/100 lx (Ground area: 84.84 m)

DIALux 4.4 by DIAL GmbH