You are on page 1of 8

004/2008 Hermes Business Campus

Bd Dimitrie Pompeiu, nr.5-7, Bucuresti, Romania


Specificatie tehnica Ventilatoare
05-August-2014
Rev. 00
Pag 1 of 8

Building Services Engineering


Where engineering begins to take shape

VENTILATIE INCENDIU
- SPECIFICATIE TEHNICA -

Ventilatoare presurizare:
1. Ventilator axial:
Caracteristici tehnice :
a.
b.
c.
d.
e.

Dimensiuni xL:
Debit de aer :
Presiune statica disponibila:
Tensiune electrica:
Putere electrica:

0.56 x 0.47 m
5.100 mc/h
600 Pa
400 V / 50 Hz
2.2 kW

Model de referinta S&P


Nr. Bucati
1 buc.
2. Ventilator axial:
Caracteristici tehnice :
a.
b.
c.
d.
e.

Dimensiuni xL:
Debit de aer :
Presiune statica disponibila:
Tensiune electrica:
Putere electrica:

0.56 x 0.47 m
5.100 mc/h
600 Pa
400 V / 50 Hz
2.2 kW

Model de referinta S&P


Nr. Bucati
1 buc.

3. Ventilator axial:
Caracteristici tehnice :

SC Pipe Design SRL > J40/8158/2002 > Str. Iovita nr. 11 Bucuresti > tel: +40 21 4104610 > E-mail : office@pipedesign.ro

004/2008 Hermes Business Campus


Bd Dimitrie Pompeiu, nr.5-7, Bucuresti, Romania
Specificatie tehnica Ventilatoare
05-August-2014
Rev. 00
Pag 2 of 8

a.
b.
c.
d.
e.

Dimensiuni xL:
Debit de aer :
Presiune statica disponibila:
Tensiune electrica:
Putere electrica:

Building Services Engineering


Where engineering begins to take shape

0.45 x 0.487 m
5.100 mc/h
500 Pa
400 V / 50 Hz
2.2 kW

Model de referinta S&P


Nr. Bucati
1 buc.

4. Ventilator axial:
Caracteristici tehnice :
a.
b.
c.
d.
e.

Dimensiuni xL:
Debit de aer :
Presiune statica disponibila:
Tensiune electrica:
Putere electrica:

0.45 x 0.487 m
5.100 mc/h
500 Pa
400 V / 50 Hz
2.2 kW

Model de referinta S&P


Nr. Bucati
1 buc.
5. Ventilator axial:
Caracteristici tehnice :
a.
b.
c.
d.
e.

Dimensiuni xL:
Debit de aer :
Presiune statica disponibila:
Tensiune electrica:
Putere electrica:

0.56 x 0.47 m
5.100 mc/h
650 Pa
400 V / 50 Hz
2.2 kW

Model de referinta S&P


Nr. Bucati
1 buc.

SC Pipe Design SRL > J40/8158/2002 > Str. Iovita nr. 11 Bucuresti > tel: +40 21 4104610 > E-mail : office@pipedesign.ro

004/2008 Hermes Business Campus


Bd Dimitrie Pompeiu, nr.5-7, Bucuresti, Romania
Specificatie tehnica Ventilatoare
05-August-2014
Rev. 00
Pag 3 of 8

Building Services Engineering


Where engineering begins to take shape

6. Ventilator axial:

Caracteristici tehnice :
a.
b.
c.
d.
e.

Dimensiuni xL:
Debit de aer :
Presiune statica disponibila:
Tensiune electrica:
Putere electrica:

0.56 x 0.47 m
5.100 mc/h
650 Pa
400 V / 50 Hz
2.2 kW

Model de referinta S&P


Nr. Bucati
1 buc.
7. Ventilator axial:
2 ventilatoare axiale functionand in serie cu urmatoarele caracteristici
tehnice :
a.
b.
c.
d.
e.

Dimensiuni xL:
Debit de aer :
Presiune statica disponibila:
Tensiune electrica:
Putere electrica:

0.56 x 0.47 m
10200 mc/h
1450 Pa
400 V / 50 Hz
2x4 kW

Model de referinta S&P


Nr. Bucati
1 buc.
8. Ventilator axial:
2 ventilatoare axiale functionand in serie cu urmatoarele caracteristici
tehnice :
a.
b.
c.
d.
e.

Dimensiuni xL:
Debit de aer :
Presiune statica disponibila:
Tensiune electrica:
Putere electrica:

0.62 x 0.565 m
10200 mc/h
1650 Pa
400 V / 50 Hz
2x5.5 kW

SC Pipe Design SRL > J40/8158/2002 > Str. Iovita nr. 11 Bucuresti > tel: +40 21 4104610 > E-mail : office@pipedesign.ro

004/2008 Hermes Business Campus


Bd Dimitrie Pompeiu, nr.5-7, Bucuresti, Romania
Specificatie tehnica Ventilatoare
05-August-2014
Rev. 00
Pag 4 of 8

Building Services Engineering


Where engineering begins to take shape

Model de referinta S&P


Nr. Bucati
1 buc.
9. Ventilator axial:
2 ventilatoare axiale functionand in serie cu urmatoarele caracteristici
tehnice :
a.
b.
c.
d.
e.

Dimensiuni xL:
Debit de aer :
Presiune statica disponibila:
Tensiune electrica:
Putere electrica:

0.62 x 0.565 m
10200 mc/h
1700 Pa
400 V / 50 Hz
2x5.5 kW

Model de referinta S&P


Nr. Bucati
1 buc.
10.

Ventilator axial:

Caracteristici tehnice :
a.
b.
c.
d.
e.

Dimensiuni xL:
Debit de aer :
Presiune statica disponibila:
Tensiune electrica:
Putere electrica:

0.56 x 0.47 m
5.100 mc/h
700 Pa
400 V / 50 Hz
2.2 kW

Model de referinta S&P


Nr. Bucati
1 buc.
11.

Ventilator axial:

Caracteristici tehnice :
a. Dimensiuni xL:
b. Debit de aer :
c. Presiune statica disponibila:

0.62 x 0.56 m
5.100 mc/h
850 Pa

SC Pipe Design SRL > J40/8158/2002 > Str. Iovita nr. 11 Bucuresti > tel: +40 21 4104610 > E-mail : office@pipedesign.ro

004/2008 Hermes Business Campus


Bd Dimitrie Pompeiu, nr.5-7, Bucuresti, Romania
Specificatie tehnica Ventilatoare
05-August-2014
Rev. 00
Pag 5 of 8

d. Tensiune electrica:
e. Putere electrica:

Building Services Engineering


Where engineering begins to take shape

400 V / 50 Hz
3 kW

Model de referinta S&P


Nr. Bucati
1 buc.

Ventilatoare desfumare:
1. Ventilator axial:
Caracteristici tehnice :
a.
b.
c.
d.
e.
f.
g.

Dimensiuni xL:
Debit de aer desfumare:
Presiune statica disponibila:
Debit de aer diluare noxe:
Presiune statica disponibila:
Tensiune electrica:
Putere electrica,pornire dahlander:

0.62 x 0.56 m
15600 mc/h
150 Pa
27300 mc/h
250 Pa
400 V / 50 Hz
6/1.5 kW

Model de referinta S&P


Nr. Bucati
2 buc.
2. Ventilator axial:
Caracteristici tehnice :
a.
b.
c.
d.
e.
f.
g.

Dimensiuni xL:
Debit de aer desfumare:
Presiune statica disponibila:
Debit de aer diluare noxe:
Presiune statica disponibila:
Tensiune electrica:
Putere electrica,pornire dahlander:

0.62 x 0.56 m
15600 mc/h
150 Pa
27300 mc/h
200 Pa
400 V / 50 Hz
6/1.5 kW

Model de referinta S&P

SC Pipe Design SRL > J40/8158/2002 > Str. Iovita nr. 11 Bucuresti > tel: +40 21 4104610 > E-mail : office@pipedesign.ro

004/2008 Hermes Business Campus


Bd Dimitrie Pompeiu, nr.5-7, Bucuresti, Romania
Specificatie tehnica Ventilatoare
05-August-2014
Rev. 00
Pag 6 of 8

Building Services Engineering


Where engineering begins to take shape

Nr. Bucati
2 buc.
3. Ventilator axial:
Caracteristici tehnice :
a.
b.
c.
d.
e.
f.
g.

Dimensiuni xL:
Debit de aer desfumare:
Presiune statica disponibila:
Debit de aer diluare noxe:
Presiune statica disponibila:
Tensiune electrica:
Putere electrica,pornire dahlander:

0.62 x 0.56 m
14400 mc/h
100 Pa
27900 mc/h
200 Pa
400 V / 50 Hz
4.4/1.1 kW

Model de referinta S&P


Nr. Bucati
2 buc.

Ventilator compensare:
1. Ventilator axial:
Caracteristici tehnice :
a.
b.
c.
d.
e.
f.
g.

Dimensiuni xL:
Debit de aer desfumare:
Presiune statica disponibila:
Debit de aer diluare noxe:
Presiune statica disponibila:
Tensiune electrica:
Putere electrica,pornire dahlander:

1.35 x 0.985 m
36480 mc/h
130 Pa
66000 mc/h
100 Pa
400 V / 50 Hz
22/4.4 kW

Model de referinta S&P


Nr. Bucati
1 buc.

SC Pipe Design SRL > J40/8158/2002 > Str. Iovita nr. 11 Bucuresti > tel: +40 21 4104610 > E-mail : office@pipedesign.ro

004/2008 Hermes Business Campus


Bd Dimitrie Pompeiu, nr.5-7, Bucuresti, Romania
Specificatie tehnica Ventilatoare
05-August-2014
Rev. 00
Pag 7 of 8

Building Services Engineering


Where engineering begins to take shape

Ventilator evacuare aer generatoare:


1. Ventilator axial:
Caracteristici tehnice :
a.
b.
c.
d.
e.

Dimensiuni xL:
Debit de aer
Presiune statica disponibila:
Tensiune electrica:
Putere electrica:

1.35 x 0.985 m
73000 mc/h
450 Pa
400 V / 50 Hz
18.5 kW

Model de referinta S&P


Nr. Bucati
3 buc.

Ventilator introducere aer trafo:


1. Ventilator centrifugal:
Caracteristici tehnice :
a.
f.
g.
h.
i.

Dimensiuni Lxlxh:
Debit de aer
Presiune statica disponibila:
Tensiune electrica:
Putere electrica,pornire dahlander:

1.25 x 1.02 x 0.9 m


11500 mc/h
200 Pa
400 V / 50 Hz
3 kW

Model de referinta S&P


Nr. Bucati
3 buc.

NOTA :
1. Toate criteriile de performanta stabilite prin prezenta specificatie
tehnica sunt obligatorii si sunt criteriu pentru acceptarea ofertelor
tehnice ;

SC Pipe Design SRL > J40/8158/2002 > Str. Iovita nr. 11 Bucuresti > tel: +40 21 4104610 > E-mail : office@pipedesign.ro

004/2008 Hermes Business Campus


Bd Dimitrie Pompeiu, nr.5-7, Bucuresti, Romania
Specificatie tehnica Ventilatoare
05-August-2014
Rev. 00
Pag 8 of 8

Building Services Engineering


Where engineering begins to take shape

2. Antreprenorul de instalatii are obligatia sa studieze atat partile


scrise cat si partile desenate. Conform unei bune practici, toate
elementele prezentate in planuri si scheme trebuie sa faca parte
integranta din oferta tehnico-economica. Partile desenate contin
informatii ce trebuie sa se regaseasca in documentatia de ofertare ;
3. Toate ofertele tehnice trebuie sa fie insotite de fise de selectie
si/sau fise tehnice din care sa rezulte clar conformitatea cu criteriile
de performanta stabilite de proiect ;
4. Orice neconformitate va aduce respingerea de catre proiectantul
general de instalatii Pipe Design a ofertei tehnice sau va transfera
integral responsabilitatea tehnico-functionala catre antreprenorul de
instalatii ;
5. Toate echipamentele prezentate trebuie sa includa in oferta tehnicofinanciara si elementele necesare pentru montaj, prinderi, sustineri,