You are on page 1of 19

ECO 112 X 2 TOP 4 and BOTTOM 5 loops SA 210 Gr C

DRUM top 1524 X 135,BOT 1509 X 150 mm SA 229 A


EVAPORATOR 4 X 172 63.5 X5.6 mm SA 210 Gr C
SH1 tube 44.5 X 5.6/4.5/7.1 -14 coils 16 tube /coil
SA 210 Gr A1/Sa 213 T-11 /SA 213 T-22
SH2 44.5 X 4.5/6.3/7.6 112 X 3 Tu SA 213 T11/T22
SH3 44.5 X 9 / 7.6- 28 Coil /16 T/ Coil SA-213 T22
RH-1 51 X 4.5 -56 coil 10 T/C SA 209 T1/Sa 213 T11
RH-2 63.5 X 4.5/5/5.6 56/5 SA 213 T22
SH DESH1- 3V + 2H,DESH2- 3 V , 2 X45 DEG 4,2 noz

Dimensions of heating surfaces


Effective heating surfaces
15034 m2
Evaporator, furnace+radiation space 689 m2
Enclosure walls
1441 m 2
Evaporator grid
769
m2
Heating surface
3999 m 2
Super heater 1
1094 m 2
Super heater 2 (suppory+grid)
3579 m2
Super heater 3
1600 m 2
Reheater 1
4358 m 2
Reheater 2
1915 m 2
ECO 1
7080 m 2
ECO 2
7954 m 2
RAPH (each one)
17430 m2

Maximum permissible steam temperature


SH 1 outlet
485 c
SH 2 inlet
430 c
SH 2 outlet
515 c
SH 3 inlet
495 c
SH 3 outlet
540 c
RH 1 inlet
360 c
RH 1 outlet
505 c
RH 2 inlet
485 c

Equipment

Opening pressure

Relieving
capacity

Safety valve 1

181.0 Kg/cm2

183.5 T/hr

Safety valve 2

183.0 Kg/cm2

187.0 T/hr

Safety valve 3

185.4 Kg/cm2

189.0 T/hr

Safety valve 4

168.4 Kg/cm2

166.5 T/hr

Safety valve 5

165.9 Kg/cm2

104.0 T/hr

Safety valve 6

50.0 Kg/cm2

200.0 T/hr

Safety valve 7

47.25 Kg/cm2

157.0 T/hr

Safety valve 8

47.72 Kg/cm2

158.7 T/hr

Safety valve 9

48.67 Kg/cm2

161.9 T/hr

You might also like