Page 93 of 109
B
UTARA
COOLING WATER
OUTFALL CHANNEL
ASH DISPOSAL WHARF
COOLING WATER INTAKE
DE
12
RM
BARGE
12000 DWT
m)
(120x30x6.5x6.0
OPTION-2
AG
DA
I-D
3
F
AW
I
F
FL
W
TR A
EAST
E
TM W
ENAT
T ER
A
R
EA
SIL
SI
A
ST
A
H
IL
TU
N
TIO
A
IN
IN
BO
TR
LL
IS
ER
K
N
TE
TA
D
A
Pagar Yg dipotong
G
E
A
R
FF
SE
IC
SIT
L.
W
ST OR
O KS
R
ES HO
TR
IN
FL
TR UE
EA
ER
IL
BO
GA
TM
S
.
PA AN
N A
T
A PE
I S RA
L
A PIH
G
A
YETTY
ER
IL
BU
FL
TR UE
EA
GA
TM
S
.
W
PL AT
A ER
N
T TR
LO
ES
LA
TE
NE
EA
TM
TO
EM
IN
ES
LI
EN
T
TA
AS
G
E
9.000 M
A
L D
(I AY DIT
F D IO
R O N
EA W A
D N L
)
TE
EA
CONVEYOR
COAL STOCK YARD
H
TP1
PLN LINE
CONVEYOR
AI-P1
L=14.7451 Ha.
TA
AA
AL
L=2.628 Ha.
PO
AR
ND
BA
IL
KE
IC
9
A
IS
CONVEYOR
13
EX
PL
30
TI
11
ST
10
PO
S
BB
12
14
7
59
N
G
52-H
TP2
F1
K
EL
F2
52-H
TRANSMISSION LINE
BE
20kV PLN
overhead line
LA
SERIES
REACTORS
PARALLEL
REACTORS
52-11
RM
LA
52-23
52-25
52-24
52-26
SWGR
52-27
52-B2B3
VT-BUS
VT
ROOM
OVER
PRESSURE
REACTORS
di/dt
OVER
PRESSURE
SWITCHGEAR
30kV
52-31
VT-BUS
52-21
52-22
RE
SPLC
ROOM
EAR
SWITCHG
FEN
FUTU
I II
BATTER
ROOM
PLN LINE
RELAY
FENCE
52-B1B2
BUS
52-14
52-12
52-13
LA
6
P.2
MCC
VALVE
A/C
THYRISTOR
ROOM
LA
VALVE
SERIES
REACTORS
UNIT
ARC
MONITOR
VALVES
COOLING
SPLC
A/C
FAULT
DAMPERS
EARTH
DETECTION
ABB
R.C.
PARALLEL
REACTORS
LA
HATCH
ROOM
PQA
AUX
ANSI
CONTROL
DESK
A/C
A/C
LA
SWGR
SPLC
ROOM
OVER
PRESSURE
OVER
PRESSURE
REACTORS
III
di/dt
OVER
PRESSURE
FENI
MCC
VALVE
A/C
THYRISTOR
ROOM
VALVE
UNIT
ARC
MONITOR
VALVES
COOLING
SPLC
A/C
FAULT
DAMPERS
EARTH
DETECTION
R.C.
ABB
HATCH
ROOM
PQA
AUX
ANSI
KW.0214
CONTROL
DESK
A/C
LL
A/C
OVER
PRESSURE
29
6
8
9
G
N
A
G
45
26
N
TO
R
II
ES
TK
5
N
47
46
TRANSMISSION LINE
BA
28
0m
20m
40m
60m
80m
100m
ORIGINAL SCALE
JULKAISTU/ISSUED
ENNAKKOKOPIO 09.08.2011
10.08.2011
PRELIMINARY
28.11.2011
Crossing with
existing 20kV PLN
overhead line
New 30kV
transmission line
28.11.2011
/12:27:56
/let16
Q
Revision
Quant.
Description
Dsgnd/Appd
Date
This drawing is the property of PYRY FINLAND OY and may be used only for purposes agreed in writing with PYRY FINLAND OY. No part
of this drawing may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical,
photocopying, recording or otherwise, without the prior written permission of PYRY FINLAND OY.
Name and address of object
Contents of drawing
ALTERNATIVE 2
R
Document type
Scales
Page(s)
1:3000/A0
Document number
Drawn
Rev.
Date/Dsgnd
LET16
Date/Chkd
10
11
12
13
14
15
16
17
18
19
20
9H000153.10-10002
Date/Appd
21
22
23
24