You are on page 1of 1

PRESSURE SWITCH DATA SHEET

Sheet No

1 of 1

TAG NO.
Service

To open/close circiuit when pressure rises


/falls above /below set point.

NO:ELAC000001
Preliminary

Prepared by

SRH

For Inquiry

Approved by

MSK

For Order

Date
Revision Index

12/8/2008
0

APPLICATION DETAILS
PROCESS MEDIA

DUSTY GASES OF CEMENT / COAL ETC

FLUID

COMPRESSED AIR

SET POINT

4 KG/CM2

PRESSURE CONNECTIONS

"NPT( F) BOTTOM ENTRY.

ENCLOSURE

DIE CAST ALUMINIUM

MAKE

SWITZER

ELECTRICAL DETAILS
MODEL

GH-901-1-C-33

SWITCH DETAILS

INST. QUALITY SANP ACTION (2NO + 2NC) MICROSWITCH CONTACT

RANGE/ REPETEABILITY

0 TO 7Kg/CM / 0.5% FSR

SENSING ELEMENT /SENSOR HOUSING

PHOSPHOR BRONZE / FORGED BRASS.

MAX. OVER TEMP.

(-10 TO 60C )

MAXI. OVER PRESSURE

18 Kg/CM

ON- OFF DIFFERENTIAL

FIXED WITH IN 10 % FSR

PROTECTION CATEGORY

WEATHER PROOF IP- 66., AS PER IS- 2147.

SEETING

EXTERNAL KNOB, TAMPER PROOF

CONTACT RATING/ NO.OF SWITCHES

15A,230V AC / TWO

CABLE ENTRY THROUGH CONDUIT

" ET CABLE GLAND OF PVC FOR 8MM. OD CABLE.

MOUNTING

FIELD

INSPECTION & TESTING REQUIREMENTS


INSPECTION

BY THERMAX,CLIENT,CONSULTANT

DOCUMENTS SUBMITTED ALONG WITH SUPPLY


03 set of O & M Manual.

REV NO

REVISION DETAILS

REV BY

PART. NO. REVISED FOR ERP

SRH

NOTE :
The serial number should be mentioned on the unit and also on all inspection reports.
Thermax spcification sheet number should be mentioned on all inspection reports
Supplier to confirm specification as mentioned above devation/ discrepancy if any should be informed before suppling the material .

DATE