You are on page 1of 6

Vibration

Analysis
3 April 1997

A Demo Vibration report on


Various Items

EFFTEK
Diagnostic Engineers
Business & Innovation Centre
Wearfield
SUNDERLAND
Tyne & Wear
SR5 2TA
Tel (0191) 5166378
Email
EFFTEK@BICNE.CO.UK

Vibration Analysis Report


3 April 1997
Machines Monitored List
Machine

Condition

No. 1 Paint Pump

O.K.

No. 2 Paint Pump

CAUTION

After Rinse Pump

ACTION

Boiler Forced Draft Fan.

O.K.

Remarks

See text
Defective motor de bearing

Vibration Analysis Report


3 April 1997

After Rinse Pump


Plot 1 shows the enveloped spectras from the motor bearings of this unit.
As can be seen, the spectra from point 1 shows a much higher level of activity with peaks
above the alarm limit of 0.5 G's. The spectra shows multiple harmonics of approximately 20
Hz. which is a bearing cage frequency.
The amplitude and characteristics of the spectra suggest that the bearing is in an advanced
stage of deterioration and it is recommended that the motor should be removed and
overhauled as soon as possible.

Vibration Analysis Report


3 April 1997

.Plot

Vibration Analysis Report


3 April 1997

No. 2 Paint Pump


Plot 2 shows the enveloped spectras from both motor bearings of this unit.
These are examples of healthy spectras and are included for comparison to those shown for
the After Rinse Pump. There is evidence of slight bearing activity shown by the peaks above
the 'carpet' level, however, these are at insignificant levels.
At this time no action is required, however, it is recommended that caution should be observed
until the next survey is carried out.

Vibration Analysis Report


3 April 1997

Plot 2