4033 7 Segment Common Anode Display Counter

4033 7 Segment Common Anode Display Event


Counter Circuit
This circuit can count 0 to 9 with reset and display test switches.

Fig.1.
PARTS LIST
R1 R7

1k

R8

10k

R9

10k

R10 -R16

680

R17

10k

C1

0.1F (104)

Q1 Q7

C828

IC1

4033

S1 S3

Push to ON Switch

Display 1

Common Anode 7 Segment Display

S1 = COUNT
S2 = RESET
S3 = LAMP TEST

This synchronous decade, or divide-by-10, counter


provides internal decoding to drive a 7-segment
display. It does not have internal count storage, nor
does it provide enough output current to directly
drive high-current display types. A divide-by-10
square-wave output is also available.
VDD = +3 TO +15V
4033 IC

4033 PIN Configuration

In normal operation, reset and clock enable are held at ground and the ripple blanking
input is connected to ground or a more-significant count stage. The counter advances
one count on each ground-to-positive (positive edge) transition of the clock input.
There are two types of outputs. At the 10 output, a square wave that is high for count

0 through 4 and low for counts 5 through 9 results. At the a through g outputs, a high
stage is produced if a display segment is to be lit. Segments b and c are used for the
1 output. Note that the 6 output includes segment a and the 9 output includes
segment d.
The counter is reset to zero by bringing the RST terminal high. This results in an a-b-cd-e-f low, along with a high on the 10 output. The RST input must be returned to
ground when counting is to continue. A high on the Test input puts all outputs high for
lamp or display test.
To automatically extinguish all right -hand zeros, ground the RB IN terminal of the mostsignificant stage and connect its RB OUT to the RB IN of the next most-significant stage,
and so on down the line. This zero blanking is defeated by making all RB IN terminals
positive.
The clock must be noiseless and have only one ground-to-positive transition per desired
count. Rise and fall times should be 5 microseconds or faster.
Maximum clock frequency is 5 megahertz at 10 volts and 2.5 megahertz at 5 volts.
Total package current at a 1 megahertz clock rate with unloaded outputs is 0.4 mA at 5
volts and 0.8 mA at 10 volts.

You can increase counting number by adding below circuits.

Fig.2.
You can add any number of fig.2. circuit for increase counting number.
You must connect;

All Y points and all Z points ( Fig.1. Y to Fig.2. Y and Fig.1. Z to Fig.2.
Z)

Fig.1. X to Fig.2. A
When you add 3rd display, second display circuit X point connect to third
display circuit (like fig.2. circuit) A point.