Unit condition

Coal CV
6500
Corex Cal CV
1890
Currection fact
3.44
Unit # 2 coal dust not in service
U#2 cond. Sub cooling study
Description
Time
Unit operation
Manual
Auto
Date:13/10/07
15:02
16:15
CW I/L temp
30.1
30.781
CW O/L temp
40.8
41.687
Lpexhoust temp-1
46.45
49.2
Lpexhoust temp-2
47.48
47.8
Lpexhoust temp-3
46.94
48
Lpexhoust temp-4
47.98
47
Lpexhoust temp-5
47.76
47.88
Lpexhoust temp-6
47.89
47.34
Cond vacuum-1
-0.891
-0.885
Cond vacuum-2
-0.891
-0.885
Cond vacuum-3
-0.890
-0.884
Absalute Vacuum in Kg/cm2
0.143
0.149
Pr in Kpa
14.020
14.610
Sat temp for Cond Pr
52.600
53.45
Load
130.6
132.5
MS pr
127.2
129.6
MS temp
535
537/533
RH temp
535
533
MS flow
401.4
408.7
Feedwater flow
407.6
414.8
1st stage Pr
120.8
123.2
1nd stage Pr
121.2
122.9
LPH-3 O/L temp
123.5
122.7
Hot well temp
44.3
45.12
Hot well temp
45.26
46.09
CEP dis temp
44.98
45.88
HPCV position
99.4/98.8 79/77
IP CV position
89.4/89.8 89/89
Coal flow
44.6
44.6
corex flow
20.3
20.8
Coal equ
50.50262 50.50262

Manual
17:15
30.5
41.5
48.36
48.2
48.2
47
47.73
47.33
-0.886
-0.886
-0.885
0.148
14.510
53.31
129.1
127.5
537/533
535
401.4
409.8
121.3
120.9
122
45.96
45.96
45.66
99.4/99.1
89/90
49.5
0
49.5