Designation

U40BS

U40BL

U40C

Mechanical failing load

kN

40

40

40

Mechanical residual strength

kN

32

32

32

Diameter of the insulating part

mm

175

175

175

Spacing

mm

100

110

146

Nominal creepage distance

mm

185

185

185

Ball and socket coupling

mm

11

11

16C

Puncture voltage in insulating medium

kV

100

100

100

50 Hz withstand voltage (dry)

kV

55

55

55

50 Hz withstand voltage (wet)

kV

33

33

33

Dry lightning impulse withstand voltage


1.2/50+/- one unit

kV

70/70

70/70

70/70

dB/kV

86/25

86/25

86/25

kg

1,7

1,7

2,0

Radio interference voltage at 0.5 MHz


Weight

Designation
Mechanical failing load
Mechanical residual strength
Diameter of the insulating part
Spacing
Nominal creepage distance
Ball and socket coupling
Puncture voltage in insulating medium
50 Hz withstand voltage (dry)
50 Hz withstand voltage (wet)
Dry lightning impulse withstand voltage
1.2/50+/- one unit
Radio interference voltage at 0.5 MHz
Weight

kN
kN
mm
mm
mm
mm
kV
kV
kV

U70BS
70
56
255
127
303
16
130
70
40

U70BL
70
56
255
146
303
16
130
70
40

kV

100/100

100/100

dB
kV
dB
kV
kg

60
20
86
25
3,4

60
20
86
25
3,4

Designation
Mechanical failing load
Mechanical residual strength
Diameter of the insulating part
Spacing
Nominal creepage distance
Ball and socket coupling
Puncture voltage in insulating medium
50 Hz withstand voltage (dry)
50 Hz withstand voltage (wet)
Dry lightning impulse withstand voltage
1.2/50+/- one unit
Radio interference voltage at 0.5 MHz
Weight

kN
kN
mm
mm
mm
mm
kV
kV
kV

U120BS
120
96
255
146
320
16
130
70
40

U120BL
120
96
255
170
320
16
130
75
40

kV

100/100

100/100

dB
kV
dB
kV
kg

60
20
86
30
3,9

60
20
86
30
3,9

Designation
Mechanical failing load
Mechanical residual strength
Diameter of the insulating part
Spacing
Nominal creepage distance
Ball and socket coupling
Puncture voltage in insulating medium
50 Hz withstand voltage (dry)
50 Hz withstand voltage (wet)
Dry lightning impulse withstand voltage
1.2/50+/- one unit
Radio interference voltage at 0.5 MHz

Weight

kN
kN
mm
mm
mm
mm
kV
kV
kV

U160BS
160
128
280
146
370
20
130
75
45

U160BL
160
128
280
170
370
20
130
75
45

kV

110/110

110/110

dB
kV
dB
kV
kg

60
20
86
35
6,2

60
20
86
35
6,2

Type

Ps-12
Ps-17,5
Ps-24
Ps-28
Ps-36
Ps-38

Leakage
Distance

230
265
360
420
540
630

Low Frequency
Withstand
Voltage kV
dry
60
70
80
90
100
110

wet
45
53
65
75
86
100

Impuls
Puncture
Withstand
Voltage
Voltage
kV
kV
100
120
140
160
180
200

120
130
150
150
160
180

Mechanical
Breaking
Load
Minimum
daN

Weight
(kg)

1.000
1.000
1.200
1.200
1.300
1.300

1,84
2,52
3,65
5,5
7,5
10,8

Type

Leakage
Distance

LSP12L
LSP17.5L
LSP 24L
LSP 24N
LSP 24L
LSP 38L
LSP 38N
LSP 38L
LSP 52L

250
350
530
400
530
720
580
720
1140

Low
Frequency
Withstand
Voltage kV
dry
wet
NA
28
NA
38
NA
50
NA
50
NA
50
NA
70
NA
70
NA
70
NA
95

Impuls
Withstand
Voltage
kV
75
95
125
125
125
170
170
170
250

Mechanical
Breaking
Weight
Load
(kg)
Minimum
daN
1250
5,8
1250
6,4
800
8
1250
9,8
1250
10,5
800
11,5
1250
12
1250
13
1250
20

Type

Number
of
sheds

H (mm)

h (mm)

D (mm)

d (mm)

r1 & r2
(mm)

LSP12L
LSP17.5L
LSP 24L
LSP 24N
LSP 24L
LSP 38L
LSP 38N
LSP 38L
LSP 52L

3
4
5
5
5
6
6
6
10

190
222
305
305
305
370
370
370
510

156
188
268
270
270
333
335
335
475

150
150
150
160
170
160
170
180
200

0
100
100
116
116
100
116
116
130

25
25
25
25
25
25
25
25
25

Designation
Insulators part diameter
Spacing
Standard coupling size
Total leakage distance
Protected leakage distance
Split-pin
Impuls Voltage 1,2/50s
- 100 % Impuls Flashover Voltage - Positive
- 50% Impuls Flashover Voltage - Positive
- 0 % - Impuls Withstand Voltage - Positive
- 100 % Impuls Flashover Voltage - Negative
-50 % Impuls Flashover Voltage - Negative
-0 % Impuls Withstand Voltage - Negative
Low Frequency Flashover Voltage Dry
Low Withstand Flashover Voltage Dry
Low Frequency Flashover Voltage Wet
Low Withstand Flashover Voltage Wet
Low Frequency Puncture Voltage in Oil
Capacity
Radio influence level at 10 kV
Radio influence level at 14 kV
Radio influence level at 18 kV
Radio influence level at 22 kV
Test at 1000 kHz
Routine test Mechanical Load
Mehanical Breaking Load
Elektromehanical Breaking Load
Weight per insulator string unit

J 70 K
255
127
16 A
290

J 70KP
255
127
16 A
292

J 100 DP
280
170
16 A
300

mm

190
R 16 A

187
R 16 A

200
R 16 A

kV
kV
kV
kV
kV
kV
kV
kV
kV
kV
kV
pF
dB
dB
dB
dB

115
105
100
120
115
105
65
60
43
40
120
52
18
49
53
60

125
117
110
130
122
115
75
70
45
38
110
52
16
34
54
64

135
130
120
145
136
127
75
70
50
45
110
56
15
37
52
61

kN
kN
kN

28
NA
70

28
70
70

40
100
100

kg

3,9

5,55

6,1

mm
mm
mm
mm

LP
60/5

LP
60/7

LP
75/14

LP
85/22

75/28

75/18

75/22

60/5

60/7

75/14

85/22

mm

60

60

75

85

75

75

75

85

85

85

85

mm

5
380

7
490

14
860

22
1.270

30
1.260

18
1.240

22
1.270

14
935

18
1.275

22
1.270

24
1.330

mm

46

46

46

46

70

57

47,6

48

57

46

44,5

mm

120

120

150

160

180

170

195

210

180

205

220

mm

260

340

690

1.060

1.075

1.060

1.090

720

1.060

1.060

1.120

mm

500

700

1.500

2.300

3.300

2.200

3.300

2.250

2.200

3.350

4.000

daN

5.500

6.700

12.000

15.000

10.000

10.000

10.000

14.000

14.000

14.000

14.000

daN

3.800

4.700

8.400

10.500

7.000

7.000

7.000

12.200

12.200

12.200

12.200

kV

150

200

405

625

550

550

550

405

550

550

550

kV

70

90

185

285

230

230

230

185

230

230

230

kg

20

26

42

28

38

36

39

50

52

mm

11

16

16

20

16

16

16

20

20

20

20

Type of insulators
Core insulators
diameter
Number of sheds
Total length
Spacing between
sheds
Overall sheds
diameter
Distance between
caps
Leakage distance
Medium breking
extention Load
Routine test
extention Load
Impuls withstand
voltage
Low Frequency
withstand voltage,
wet
Weight, cca
Standard coupling
size

You might also like