Professional Documents
Culture Documents
HEAT EXCHANGERS(1)
A-1 AIR FIN COOLER
Duty: 3.919 MM BTU/hr
U = 89 (overall, bare)
Area = 594 ft2 bare, 4,772 ft2 finned
LMTD = 74.1 F
Air Side:
100 F in, 145 F out
Fluid Side:
250 F in, 475 psig
150 F out, 470 psig
MAWP:
500 psig @ 400 F
E-1, E-2, E-3 COLUMN V-1 INTERCOOLERS
Each: Double pipe multi-tube
6-5/8 OD x 15
Duty: 796,000 BTU/hr
U = 55.8
Area = 520 ft2 (bare tube)
LMTD = 27.4 F
Water in tubes: 75 F in, 95 F out
Hydrocarbons in shell: 125 F in, 100 F out
MAWP: shell and tubes 500 psig, 650 F
E-4 COLUMN V-1 REBOILER
Duty: 6.55 MM BTU/hr
U = 158
Area = 192 ft2
CMTD = 216 F
V-2 bottoms in tube, 463 F in, 398 F out
V-1 bottoms in shell, 184 F in, 213 F out, 41.4% vapor
MAWP: Shell - 275 psig, 235 F
Tubes - 270 psig, 650 F
E-5 COLUMN V-2 FEED BOTTOMS EXCHANGER
Duty: 3.45 MM BTU/hr
U = 53.7
Area = 452 ft2
CMTD = 142.2 F
Shell V-2 bottoms, 463 F to 283 F
MAWP: 220 psig, 650 F
Tubes V-2 feed, 186 F to 237 F
MAWP: 229 psig, 450 F
Page 1 of 8
Page 2 of 8
Page 3 of 8
FIRED HEATER
H-1 COLUMN V-2 REBOILER
Duty: 15 MM BTU/hr @ 84% efficiency (LHV)
Temp: 430 F in, 500 F out, (33% vapor)
Pressure: 164 psig in (before control valve), 107 psig out
MAWP: 150 psig, 600 F
Page 4 of 8
Page 7 of 8
V-13 COLUMN
Diameter 6 6
Height 115
50 Actual Trays 35 theoretical, excluding reboiler and partial condenser
MAWP: 155 psig, 480 F
V-17 COLUMN V-13 OVERHEAD ACCUMULATOR
Diameter 12
Height 20
MAWP: 155 psig, 480 F
V-18 COLUMN V-1 WATER COLLECTION KEG
Diameter 3
Height 6
MAWP: 229 psig, 235 F