You are on page 1of 2

TCR ARABIA

P.O Box 3422, Opp Gasoline Station, beside Al-kadi Tent factory, near King Abdul-aziz Sea Port - Dammam
31471, Saudi Arabia.
Tel: +966-3-8475785-231 E-Mail: sales@tcr-arabia.com www.tcr-arabia.com

ULTRASONIC TESTING REPORT


Client:
General
Electricity
Project: Dhuruma O&M STG-10
Reference Code:
Article 4

ASME V

Location: PP11 Dhuruma,


Riyadh
Test Procedure:
QCP/TCR/UT/1.0REV.1
Acceptance Standard: AS PER

Date Tested: October 16 17,


2015
Report No.:
Page:

1 of 1

PROCEDURE

INSPECTION PARAMETERS
Flaw Detector
Examination System
Scanning
+6dB
dB
Defect Report Level
Defect Reject Level
Material

Bearing
Metal

Area Scanned

MODSONIC
A Scan
Reference
54 dB
dB
As per procedure
Range
100mm
Sensitivity

80% BWE

Accessible Area

Model/SN
Calibration block

E3494-0912
Step Wedge, V2 Block

Couplant

Ultra Gel

Probe
Angle

Probe Type

TR Probe
TwinCrystal
Surface Condition
0

Crystal
Size

Frequency

10mm

4MHz

Normal

TEST RESULTS
S.I No.
Description
1
Turbine End Thrust Pad T2(Top)
2
Turbine End Thrust Pad T3 (Top)
3
Turbine End Thrust Pad T4 (Top)
4
Turbine End Thrust Pad T5 (Top)
5
Turbine End Thrust Pad T6 (Bottom)
6
Turbine End Thrust Pad T7 (Bottom)
7
Turbine End Thrust Pad T8 (Bottom)
8
Turbine End Thrust Pad T1 (Bottom)
9
Turbine Side Tilting Pad T1-B2
10
Turbine Side Tilting Pad T1-B3
11
Turbine Side Tilting Pad T1-B4
12
Turbine Side Tilting Pad T1-U1
13
Turbine Side Tilting Pad T1-U5
14
Turbine Side Tilting Pad T1-U9
15
Generator Side Tilting Pad T2-UR
16
Generator Side Tilting Pad T2-UC
17
Generator Side Tilting Pad T2-ULL
18
Generator Side Tilting Pad T2-BC
19
Generator Side Tilting Pad T2-BR
20
Generator Side Tilting Pad T2-BL
NOTE: NUA (No Unbonded Area)
Inspected by:

Observation
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA
NUA

Result
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable
Acceptable

Reviewed by:

RONEL CUSTODIO
TCR ARABIA NDT Level II
Date:

October 21, 2015

TCR ARABIA NDT Level III


Date:

TCR ARABIA
P.O Box 3422, Opp Gasoline Station, beside Al-kadi Tent factory, near King Abdul-aziz Sea Port - Dammam
31471, Saudi Arabia.
Tel: +966-3-8475785-231 E-Mail: sales@tcr-arabia.com www.tcr-arabia.com

ATTACHMENTS: Three (3) pages of photos.

Inspected by:

Reviewed by:

RONEL CUSTODIO
TCR ARABIA NDT Level II
Date:

October 21, 2015

TCR ARABIA NDT Level III


Date:

You might also like