Professional Documents
Culture Documents
ORIGIN ≡ 1 hm ≡ 100m
1. Formula reductionala.
3
m
k := 0.28 - coeficient de transformare a intensitatii ploii din mm/ora in m/s si a suprafetei din km 2 in m 2 ;
s
I60.1% := 100 - intensitatea maxima orara a ploii cu probabilitatea de depasire de 1% exprimata in mm/ora;
Pcalcul = 5 ⋅ % Pverificare = 1⋅ %
α⋅ I60.1%⋅ FBH m
3
Q1% := k⋅ Q1% = 8.57
(FBH + 1)
n s
Debitele maxime cu diferite probabilitati p% conform distributiei Pearson III cu coeficientul de variatie Cv = 1 si
coeficientul de asimetrie Cs= 4*Cv se calculeaza cu relatia: Qp% = λ1p⋅ Q1%, unde λ1p este coeficientul de trecere
T 1 2 3 4 5 6 7 8
p = ⋅%
1 0.010 0.100 0.500 1.000 2.000 5.000 10.000 20.000
3
T 1 2 3 4 5 6 7 8 m
Qp% =
1 20.91 14.74 10.46 8.57 6.77 4.63 3.17 1.97 s
Corelatii & interpolare
Debite caracteristice
P verificare P calcul
% %
20
Debit [mc/s]
10
(
Qp interp P verificare )
(
Qp interp P calcul )
0
0.01 0.1 1 10 100
Pverificare = 1⋅ %
3 3
1 8.4 m
( )
m
pp := % Qpp% := ⋅ Qpinterp Pverificare = 8.57
5 4.8 s s
3
( )
m
Qpinterp Pcalcul = 4.628
s
% %
20
Debit [mc/s]
10
0
0.01 0.1 1 10 100
Unda de viitura
Harta cu zone caracteristice pentru parametrul lambda
aλ := 0.4
λ := 1.50
Harta cu izoliniile stratului scurs h pentru probabilitatea de depasire de 1%
h1% := 50mm
2
h 1%⋅ λ⋅ FBH⋅ km
Tc := Tc = 8.508⋅ hr −1
Q1% Tc ⋅ a λ = 21.27⋅ hr Tt
Tc 2
k := 2 k = 2 .. 2.5 Tt := Tc⋅ ( 1 + k) Tt = 25.525⋅ hr = 0.333 h 1%⋅ FBH⋅ km
Tt = 0.222 γ
Q1%⋅ Tt
Tc
se mai poate alege: Tt :=
aλ
2
h 1%⋅ FBH⋅ km
γ := γ = 0.267
Q1%⋅ Tt
Vverificare hr
Q maxv
8 3
hm
Q maxc
4
0.1
2 Qmaxc⋅ Tt⋅ γ
Cr2⋅
3
hm
0 0
0 10 20
Timp [hr]
Viitura de verificare - metoda hiperbolica (Cadariu)
Viitura de calcul - metoda hiperbolica (Cadariu)
Volumul viiturii de verificare Cr2 = 35.285⋅ %
Volumul viiturii de calcul
10
1
0.1
0.01
0 5 10 15
Debit [mc/s]
Viitura de verificare - metoda hiperbolica (Cadariu)
Viitura de calcul - metoda hiperbolica (Cadariu)
Debite caracteristice
Debite caracteristice
Calculul vanei
Dgolire := 400mm Cota coronament := 123.70mdM NNR := 119.45mdM
Dgolire
Cota golire := 117.2m −
2
Hb := Cota coronament − Cota golire
Hb = 6.7 m
ζintrare := 0.5 ζiesire := 0.50
h := 0.01mm , 1cm .. Hb
ζintrare
ζo :=
ζiesire
1
ϕgolire := ϕgolire = 0.707
1+
∑ζo
D 2
Dgolire m3
golire π⋅ Dgolire
Qg( h) := if h > , ϕgolire⋅ ⋅ 2g⋅ h − ,0
2 4 2 s
Cheia vanei
122
120
NNR
2
118
Dgolire
0
0 0.5 1 1.5
Debitul [mc/s]
Cheia golirii
Cheia calugarului
Dgolire
Cota golire := 117.2m −
2
Hb := Cota coronament − Cota golire
Hb = 6.9 m
ng := 0.014 Rugozitatea conductei golirii de fund
h := 0.01mm , 1cm .. Hb
⋅
8 g
ζintrare λ :=
ζo := 2 m
ζiesire
1
6
s
2
∑ζo = 1 λ = 0.026
1 Dgolire
⋅
0.014 4 ⋅ m
1
ϕgolire := ϕgolire = 0.563
Lgolire
1+
∑ζo + λ⋅ Dgolire
D π⋅ Dgolire
2
Dgolire m3
golire
Qg( h) := if h > , ϕgolire⋅ ⋅ 2g⋅ h − ,0
2 4 2 s
Dgolire
−h D D
Pc( h ) := 2 ⋅ acos ⋅ golire if h ≤ golire
2
Dgolire 2 2
2
Dgolire
− ( Dgolire − h ) D D
360deg − 2 ⋅ acos 2 ⋅ golire if h > golire ∧ h < D
D golire 2 2 golire
2
Dgolire
360 ⋅ deg otherwise
2
hx := Dgolire⋅ 100 %
2
Dgolire
2 2g ⋅ hx −
π⋅ Dgolire P ( hx) ⋅ m
∆h := ϕgolire⋅ ⋅
2 ⋅ c ⋅ Lgolire
4 1 Ac( hx)
Ac( hx) ⋅
m
6
s Ac( hx) − 1
⋅ ⋅m
ng Pc( hx)
1
m
Ac( h ) ⋅ 6
s Ac( h) − 1 Ac( h) − 1 ∆h
Qc( h) := ⋅ ⋅m ⋅ ⋅m ⋅ if h < Dgolire
ng Pc( h ) Pc( h ) Lgolire
Qg( h ) otherwise
Qg( h ) otherwise
122
120
NNR
118
Dgolire
hx
0
0 1 2 3 4
Debitul [mc/s]
Cota golire = 116.8 m
Cheia golirii
Dgolire = 800 ⋅ mm
Cheia calugarului
Cheia calugarului
Dgolire NNR−Cota golire
3 6
2 4
Debit [mc/s]
Viteza [m/s]
1 2
Qgolire( hx)
0 0
0 2 4 6 8
Sarcina [m]
Debit
Viteza
hxg := 2m
mcg := 0 Cota devg := 119.45m hxg := Cota devg − Cota golire NNR = 119.45 m Cota coronament = 123.7 m
3
m
3
Cota coronament − NNR = 4.25 m
Qdg( h ) := if h > 0 ⋅ m , mdg⋅ ( b dg + mcg⋅ h) ⋅ 2 ⋅ g⋅ h , 0
2
s
h1 := 3.42m
3
m
Qd2( h ) := 0 if h ≤ hxg
s
Qdg( h − hxg) if h < h1 ∧ h > hxg
Qgolire( h) otherwise
6
122
120
118
0
0 1 2 3
Qgolire( h) := Qd2( h )
122
Cota lac [mdM]
120
NNR
118
Cotagolire
116
0 0.05 0.1 0.15
Volum [hmc]
Domeniu de calcul
Curba de volum a laculului
Timpul de golire
L
Qm - debitul modul ce tine seama de afuerea in lac Qm := 30
s
NNR − Cotagolire
ng := trunc ig := 1 .. ng
pas
Timpul de golire al acumularii
1
119
0.5
Qm
0
118
Cotagolire+D golire
− 0.5
117
−1
−3
0 5× 10 0.01
0.5
Volume evacuate [hmc]
Q
Qm (
golire Dgolire ) 0
−4
5× 10
− 0.5
0 −1
117 118 119
Cota [mdM]
Volume evacuate
Debite defluente
Sl( hx) :=
d
dhx
Vl( hx) Slc := Sl Cota lac
il il
(
Sms := supsmooth Cota lac , Slc ) ( )
Sm := ksmooth Cota lac , Slc , 1m
md := 0.35 Cota dev := 122.2 mdM NNR = 119.45 m Cota coronament = 123.7 m
3
m
3
Cota coronament − NNR = 4.25 m
Qd ( h ) := if h > 0 ⋅ m , md ⋅ ( b d + mc⋅ h) ⋅ 2 ⋅ g⋅ h , 0
2
s
hx := 5.1m
Given
(
Qgolire( hx) − Qd hx − Cota dev − Cota golire = 0
)
hx := Minerr( hx)
hx = −4.3 m
Qd1( h ) := ( )
Qd h − Cota dev − Cota golire if h < hx
Qgolire( h) otherwise
Cheile limnimetrice ale evacuatorilor
Cotacoronament
122
Cota [mdM]
Sarcina [m]
120
NNR
118
D golire
0
0 10 20 30
Debit [mc/s]
Debitul calugarului
Debitul deversorului lateral (descarcatorul de ape mari)
Debitul descarcatorilor - cumulat
Unda de viitura
T T
3 ⌠ t 3 ⌠ t 3
Qmaxv⋅ Tt⋅ γ = 0.247⋅ hm Qc2( t) dt = 0.141⋅ hm Qv2( t) dt = 0.247⋅ hm
⌡ ⌡
0 0
T T
⌠ t ⌠ t
Qc2( t) dt Qv2( t) dt
⌡ ⌡ 3 3
0 0 m m
Qm1 := Qm2 := Qm1 = 1.632 Qm2 = 2.856
Tt Tt s s
T T
⌠ c ⌠ c
Qc2( t) dt Qv2( t) dt
⌡ ⌡
0 0
Cr1 := Cr2 := Cr1 = 0.545 Cr2 = 0.545
T T
⌠ t ⌠ t
Q ( t ) dt Q ( t ) dt
c2 v2
⌡T ⌡T
c c
hr
Q maxv
8
0.2
Volum [hmc]
Debit [mc/s]
4
0.1
Qm2
0 0
0 10 20
Timp [hr]
Q verificare
Q calcul
Volum afluent pentru viitura de verificare
m m
3 3
Qlin( t) := if Qv2( t) > 0 , Qv2( t) , 0
s s mdM ≡ m
Q1lin( t) := Qv2( t) mdc := 0.045 bdc := 120m mcc := 80 bdc + mcc ⋅ ( 80cm) = 184 m
- lungimea coronamentului
3
( ( )) + Qgolire(if (h > Cotagolire , h − Cotagolire, 0m))⋅ kz
m
Q( h ) := if h ≤ 0⋅ m , 0 ⋅ , Qd if h > Cota dev , h − Cota dev , 0m
s
Tt
t := 0hr , p timp .. Tt itc := 2 .. tc := 0hr , ptimp .. Tt Cota dev = 122.2 m
p timp
( )
Q1lin it⋅ p timp + Q1lin( it − 1) ⋅ ptimp
V1v := ⋅ p timp ...
it
2
+ V1v
it− 1 (
− Q Cotalin lac V1v( ))
it − 1
⋅ ptimp if ( h > Cota coronament ) , mdc⋅ b dc + mcc ⋅ ( h − Cota coronament ) ⋅
Determinarea momentului de timp la care debitul defluent este maxim
Td 1 := p timp⋅ match( max( V1v) , V1v) Td 1 = 8.667⋅ hr
(
hL1 := max Cotalin lac( V1v) ) hL1 = 122.649 m hL1 − Cota coronament = −105 ⋅ cm
3
NNR = 119.45 mCota coronament = 123.7 m
( ( ))
m
Qdmax1 := Q max Cotalin lac( V1v) Qdmax1 = 5.571
s
( (
Qcc1 := Q if Cotalin lac V1v
it it − 1 ( )
> 0 , Cotalin lac V1v
it −1
,0 ( ) ))
Hidrografele pentru viitura de verificare
10
Td1
hr
8
Debit [mc/s]
0
0 10 20 30
Timp [hr]
Debit afluent
Debit defluent
hr hr
123 8
hL1
Debit [mc/s]
122 6
h [m]
121 4
120 2
119 0
0 10 20 30
Timp [hr]
Pverificare = 1⋅ %
h(t) pentru viitura de verificare
Pcalcul = 5 ⋅ %
Cota coronament
Cota deversor hL1 − Cota coronament = −105 ⋅ cm
NNR
NNR = 119.45 m
Debit afluent
Debit defluent
Q1lin( t) := Qc2( t)
3
( ( ))
m
Q( h ) := if h ≤ 0⋅ m , 0 ⋅ , Qd if h > Cota dev , h − Cota dev , 0m
s
V1v :=
( )
Q1lin it⋅ p timp + Q1lin( it − 1) ⋅ ptimp
⋅ p timp ...
it 2
+ V1v
it− 1 (
− Q Cotalin lac V1v ( ))⋅ptimp
it − 1
( ) ( (
hL1 := max Cotalin lac( V1v) hL1 = 122.636 mhL1 − Cota coronament = −106 ⋅ cmQdmax1 := Q max Cotalin lac( V1v) − Cota dev ))
3
m
Qdmax1 = 0 NNR = 119.45 mCota coronament = 123.7 m
s
( (
Qcc2 := Q if Cotalin lac V1v
it it − 1 (
> 0 , Cotalin lac V1v
it −1
,0) ( ) ))
Hidrografele pentru viitura de calcul
5
Td1
hr
4
Debit [mc/s]
0
0 10 20 30
Timp [hr]
Debit afluent
Debit defluent
Evolutia cotei apei in lac pentru debitul de calcul
124 5
Td2 Td1
hr hr
123 4
hL1
Debit [mc/s]
122 3
h [m]
121 2
120 1
119 0
0 10 20 30
Timp [hr]
Pverificare = 1⋅ %
h(t) pentru viitura de verificare
Pcalcul = 5 ⋅ %
Cota coronament
Cota deversor hL1 − Cota coronament = −106 ⋅ cm
NNR
NNR = 119.45 m
Debit afluent
Debit defluent
Cr2 = 35.285
golire
∧ h < Dgolire
2
3
3
( )
2 m
2 ⋅ g⋅ h − Cota coronament ,0
s
35.285⋅ %