Quad-band Panel

Frequency Range
Dual Polarization
HPBW
Adjust. Electr. DT

R1

R2

698862

Y1

Y2

880960 16952690 16952690

65

65

65

65

212

212

2.512

2.512

set by

4XPol Panel 698862/880960/16952690/16952690 65/65/65/65 15.5/16/18/18dBi


212/212/2.512/2.512T

80010868

Type No.
Low bands
Frequency Range
(MHz)
Gain at mid Tilt
(dBi)
Gain over all Tilts
(dBi)
Horizontal Pattern:
Azimuth Beamwidth
()
Front-to-Back Ratio,
Total Power, 30
(dB)
Cross Polar Discrimination
at Boresight
(dB)
Cross Polar Discrimination
over Sector
(dB)
Azimuth Beam
Port-to-Port Tracking
(dB)
Vertical Pattern:
Elevation Beamwidth
()
Electrical Downtilt
continuously adjustable
()
Tilt Accuracy
()
First Upper Side Lobe
Suppression
(dB)
Upper Side Lobe
Suppression, 20 Sector
above Main Beam
(dB)

R1, connector 1 2

R2, connector 3 4

698 862
698 806
15.0
14.9 0.5

790 862
15.3
15.2 0.4

880 960
880 960
15.9
15.8 0.3

71 2.5

68 2.4

66 1.6

> 22

> 24

> 26

> 22

> 22

> 19

>7

>7

> 8.5

<2

< 2.5

< 2.5

10.3 0.5

9.4 0.5

11.0 0.9
2 12

2 12

< 0.5

< 0.4

< 0.3

> 16

> 18

> 18

> 16

> 18

> 18

Cross Polar Isolation


Port to Port Isolation

Max. Effective Power per Port

> 30 dB

> 30 dB

> 28 dB (R1//R2)
> 30 dB (R1//Y1,Y2)
> 30 dB (R2//Y1,Y2)
250 W (at 50 C ambient temperature)

936.4365/a ngmn 04.18.04 Subject to alteration.

Values based on ngmn-P-BASTA requirements.

www.kathrein.de

80010868 Page 1 of 4

KATHREIN-Werke KG Anton-Kathrein-Strae 1-3 P.O. Box 10 04 44 83004 ROSENHEIM GERMANY Phone +49 8031 184-0 Fax +49 8031 184-820

Quad-band Panel

Left side, high band


Frequency Range
(MHz)
Gain at mid Tilt
(dBi)
Gain over all Tilts
(dBi)
Horizontal Pattern:
Azimuth Beamwidth
()
Front-to-Back Ratio,
Total Power, 30
(dB)
Cross Polar Discrimination
at Boresight
(dB)
Cross Polar Discrimination
over Sector
(dB)
Azimuth Beam
Port-to-Port Tracking
(dB)
Vertical Pattern:
Elevation Beamwidth
()
Electrical Downtilt
continuously adjustable
()
Tilt Accuracy
()
First Upper Side Lobe
Suppression
(dB)
Upper Side Lobe
Suppression, 20 Sector
above Main Beam
(dB)

Y1, connector 5 6
1695 1880
17.4
17.3 0.5

1850 1990
17.8
17.7 0.3

1695 2690
1920 2170
17.9
17.8 0.3

2300 2400
17.6
17.5 0.4

2500 2690
18.3
18.1 0.6

64 4.2

61 3.0

60 2.5

65 5.0

61 5.6

> 26

> 26

> 26

> 24

> 24

> 16

> 21

> 25

> 18

> 15

>8

>8

> 9.5

>9

> 10

<2

<2

< 1.5

< 1.5

<2

6.3 0.4

5.9 0.2

5.6 0.4

4.9 0.2

4.4 0.3

2.5 12
< 0.2

< 0.2

< 0.2

< 0.2

< 0.2

> 19

> 19

> 18

> 17

> 18

> 15

> 15

> 14

> 14

> 15

Cross Polar Isolation


Port to Port Isolation

> 28 dB
> 30 dB (R1,R2//Y1)
> 30 dB (Y1//Y2)
200 W (at 50 C ambient temperature)

Max. Effective Power per Port


Values based on ngmn-P-BASTA requirements.

Frequency Range
(MHz)
Gain at mid Tilt
(dBi)
Gain over all Tilts
(dBi)
Horizontal Pattern:
Azimuth Beamwidth
()
Front-to-Back Ratio,
Total Power, 30
(dB)
Cross Polar Discrimination
at Boresight
(dB)
Cross Polar Discrimination
over Sector
(dB)
Azimuth Beam
Port-to-Port Tracking
(dB)
Vertical Pattern:
Elevation Beamwidth
()
Electrical Downtilt
continuously adjustable
()
Tilt Accuracy
()
First Upper Side Lobe
Suppression
(dB)
Upper Side Lobe
Suppression, 20 Sector
above Main Beam
(dB)

Y2, connector 7 8
1695 1880
17.3
17.3 0.4

1850 1990
17.7
17.6 0.3

1695 2690
1920 2170
18.0
17.9 0.4

2300 2400
18.4
18.3 0.3

2500 2690
18.4
18.3 0.4

64 2.4

63 3.2

62 2.9

60 2.0

60 2.7

> 24

> 23

> 24

> 23

> 25

> 22

> 24

> 23

> 20

> 19

> 15.5

> 14.5

> 13

> 7.5

>9

<1

<1

<1

<2

<2

7.1 0.4

6.7 0.3

6.4 0.4

5.5 0.4

5.0 0.2

< 0.2

< 0.2

< 0.2

< 0.2

< 0.2

> 20

> 21

> 22

> 17

> 20

> 13

> 16

> 15

> 15

> 16

2.5 12

Cross Polar Isolation


Port to Port Isolation
Max. Effective Power per Port

> 28 dB
> 30 dB (R1,R2//Y2)
> 30 dB (Y1//Y2)
200 W (at 50 C ambient temperature)

Values based on ngmn-P-BASTA requirements.

Page 2 of 4 80010868

www.kathrein.de

KATHREIN-Werke KG Anton-Kathrein-Strae 1-3 P.O. Box 10 04 44 83004 ROSENHEIM GERMANY Phone +49 8031 184-0 Fax +49 8031 184-820

936.4365/a ngmn 04.18.04 Subject to alteration.

Right side, high band

Quad-band Panel

Mechanical specifications

Impedance
()
VSWR
Return Loss
(dB)
Interband Isolation
(dB)
Passive Intermodulation (dBc)
Polarization
()

Input
Connector Position
Adjustment Mechanism

50
< 1.5
> 14
> 28
< 150 (2 x 43 dBm carrier)
+45, 45

Wind load
(at Rated Wind Speed:
150 km/h)

(N)

Values based on ngmn-P-BASTA requirements.


Max. Wind Velocity
(km/h)
Height / Width / Depth (mm)
Category of
Mounting Hardware
Weight
(kg)
Packing Size
(mm)
Scope of Supply

Accessories (order separately if required)

8 x 7-16 female long neck


bottom
FlexRET,
continuously adjustable
Maximum
1210
Frontal
1160
Lateral
390
Rearside
1210
241
1921 / 377 / 169
H (Heavy)
35.0 / 37.0 (clamps incl.)
2121 / 397 / 212
Panel, FlexRET and
2 units of clamps
for 42 115 mm diameter

9

Type No.

Description

Remarks

Weight
approx.

Units per
antenna

85010002
85010003
85010008

1 clamp
1 clamp
1 downtilt kit

Mast: 110 220 mm diameter


Mast: 210 380 mm diameter
Downtilt angle: 0 11

2.7 kg
4.8 kg
6.5 kg

2
2
1

1.1 kg

2
1

72

13

Electrical specifications, all systems

Accessories (included in the scope of supply)


1 clamp
FlexRET

Mast: 42 115 mm diameter

For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit.
Wall mounting: No additional mounting kit needed.
Material:

Reflector screen: Aluminum.


Fiberglass housing: It covers totally the internal antenna components.
The special design reduces the sealing areas to a minimum and
guarantees the best weather protection. Fiberglass material guarantees
optimum performance with regards to stability, stiffness, UV resistance
and painting. The color of the radome is light grey.
All nuts and bolts: Stainless steel or hot-dip galvanized steel.

Grounding:

The metal parts of the antenna including the mounting kit and the inner
conductors are DC grounded.

www.kathrein.de

1921
1948
1988

936.4365/a ngmn 04.18.04 Subject to alteration.

738546
86010153

80010868 Page 3 of 4

KATHREIN-Werke KG Anton-Kathrein-Strae 1-3 P.O. Box 10 04 44 83004 ROSENHEIM GERMANY Phone +49 8031 184-0 Fax +49 8031 184-820

Quad-band Panel

Layout of interface:

Right

Left

R2

169*

1695

Y1

Y1

R1

Y2

Y2

54

R1

104

195*

R2

124
224.5
325
377*
Bottom view
* Dimensions refer to radome

Correlation Table
Frequency range

Array

Connector

698 862 MHz


880 960 MHz
1695 2690 MHz
1695 2690 MHz

R1
R2
Y1
Y2

12
34
56
78

1x

Y1
R1
Left

Page 4 of 4 80010868

936.4365/a ngmn 04.18.04 Subject to alteration.

R2

Y2
Right

Any previous data sheet issues have now become invalid.

www.kathrein.de

KATHREIN-Werke KG Anton-Kathrein-Strae 1-3 P.O. Box 10 04 44 83004 ROSENHEIM GERMANY Phone +49 8031 184-0 Fax +49 8031 184-820

You might also like