You are on page 1of 26

( CONC

( type of cement )

( specific gravity )

INPUT TYPE
slump
1

Extremely

Stif

2
4
5
INPUT

TYPE

Very stif

Stif plastic
Plastic

0.00

cm.

0-2.5

cm.

0.00

2.5-7.5

cm.

7.5-12.5

Flowing (Very 12.5-19.5


5

cm.

slump

cm.
cm.

7.5-12.5

( 28 )

( maximum size )

( specific gravity )

( unit weight )

slump

( moisture content )

( absorption )

( specific gravity )

( fine modulus )
( moisture content )

( absorption )
=

175

MIX DESIGN

0.62


( )

( )

( )

( )

( )

( )

( )

( CONCRETE MIX DESIGN )

t)

ity )

3.15

250

ksc.

40

mm.

cm.

e)

ity )

( sheet 2 TABLE A2.3.5.1(a))

slump
=

ity )

/.

1600

100
2

0.5

2.64

6.00

kg/m^3

0.72

2.68

2.80
0.7

%
%

%
%

%
=

1152

kg/m^3

0.175

m^3

0.430

m^3

=
=
=

1 ( )

175

kg

1152

kg

282.258

( )

780.235

2389.493

kg

1 ( )
116.368

kg

1175.040

kg

2400.715

349.103

827.049
.
kg

0.296

m^3
m^3

780.235 kg

kg

( )

0.01

m^3

kg

282.258

0.090

5.645

282.258 kg/m^3

kg
kg
kg

1175.040 kg
827.049 kg
1.500
5.300

%
%

116.368 kg

5.645

846.774

kg

2481.147

kg

3525.120
7202.144

kg
kg

16.935

Table

A 2.3.4.3

Compressive
at

28

RELATIONSHIPS BETWEEN WATER - CEMENT

strength

days , kgf/cm^2

Water - cement

Non-air-entrained

concrete

ratio , by

concrete

0.80

0.71

170

0.76

0.67

160
180
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
350
360
370
380
390

0.78
0.74
0.70
0.68
0.67
0.65
0.64
0.62
0.61
0.59
0.58
0.56
0.55
0.54
0.52
0.51
0.49
0.48
0.47
0.46
0.45
0.44

weight

Air-entrained

150

0.69
0.65
0.61
0.59
0.58
0.56
0.55
0.53
0.52
0.50
0.49
0.47
0.46
0.45
0.44
0.42
0.41
0.40
0.39
0.38
0.36
0.35

RATIO

400

0.43

0.34

420

0.41

0.32

410
430
440
450
460
470
480
490
500

0.42
0.40
0.39
0.38
0.37
0.36
0.35
0.34
0.33

0.33
0.31
0.30
0.29
0.28
0.27
0.26
0.25
0.24

EMENT

RATIO

weight

slump

INPUT TYPE

slump (cm.)

Extremely

Stif

2
4
5
6

Very stif

dry

0.00
0.00

0-2.5

Stif plastic
Plastic

Flowing (Very Plast

10

2.5-7.5

205.00

12.5-19.5

240.00

7.5-12.5

225.00
3.00

150

0.80

170

0.76

0.70

160
180
200
210
220
230
240
250
260
270
280
290
300

0.78
0.74
0.68
0.67
0.65
0.64
0.62
0.61
0.59
0.58
0.56
0.55

INPUT TY

2
4
5
6

310

0.54

330

0.51

320
340
350
360
370
380
390
400
410
420
430
440
450
460
470
480
490
500

0.52
0.49
0.48
0.47
0.46
0.45
0.44
0.43
0.42
0.41
0.40
0.39
0.38
0.37
0.36
0.35
0.34
0.33

1 ..
1 .. (mm.)
12.5

20

50

75

185

180

160

155

145

230

210

205

185

180

170

2.5

Very stif

40

200
215

Extremely

25

200
2

slump (cm.)
dry

Stif

Stif plastic
Plastic

1.5

175
1

170
0.5

160
0.3

10.0

15.0

0.00

190

170

0-2.5

135

130

0.00

2.5-7.5

7.5-12.5

Flowing (Very Plas12.5-19.5

195

160
108
100

97

145
106
100

98

(mm.)

150

125
140
0.2

20.0

25.0

40.0

145

140

130

115

115

120

130

125

104

106

100

100

100

100

125
109
100
100

TABLE A2.3.5.1(a)

VOLUME OF

COARSE

CONCRETE (METRIC)

CONSISTENCY ( 8-13
MAXIMUM SIZE
OF AGGREGATE
10.00

MM.

15.00
20.00
25.00
40.00
TABLE A2.3.5.1(b)

Extremely dry

CM

PLASTIC

SLUMP )

FINENESS MODUL

2.40

2.50

0.59

0.58

0.50

0.49

0.66

0.65

0.71

0.70

0.76
VOLUME OF

0.75
COARSE AGGREGATE PER

CONCRETE FOR

DIFFERENT

cm.

10.0

190

UN

CONSISTENCIE

Percentage

Slump

Description

OF

of

the

Very stif
Stif

Stif Plastic
Plastic

Flowing

160

2.5-7.5

108

0-2.5

135

7.5-12.5

100

12.5-19

97

Table

A 2.2.3.1 (c)

DIFFERENT

Consistency

Description
1

Extremely

Stif

2
4
5
6

Slump,

dry

Very

stif

Stif

plastic

Flowing

cm.

0-2.5

2.5-7.5

7.5-12.5

12.5-19

Approximate

amount of entrapped

Extremely

dry

Stif

in

2
4
5
6

non-air-entrained

Very

stif

Stif

plastic

concrete , %

Recommended

air

0-2.5

2.5-7.5

Plastic

Flowing

CONSISTENCIES

Plastic

7.5-12.5

average

12.5-19
total

air

APPROXIMA

content , %

ETRIC)

( 8-13

OF

CM

PLASTIC

SLUMP )

FINENESS MODULUS OF

2.60

2.70

2.80

2.90

0.57

0.56

0.55

0.54

0.48

0.47

0.64

0.67

0.73
UNIT

CONSISTENCIES

of

0.62

0.68

0.74

Percentage

0.46

0.63

0.69

GGREGATE PER

RENT

SAND

the

0.61
0.66
0.71

VOLUME OF

values

( mm.)

0.72

0.45

shown

in

table A2.3.5.1(a)

12.5

20.0

25.0

40.0

170

145

140

130

130

125

125

106

104

106

109

98

100

100

130

115

100

2.3.1 (c)

NT

145

115

100

100

APPROXIMATE MIXING WATER

CONSISTENCIES AND MAXIMUM


Relative

water

content, %

Non-air-entrained

content , %

78
83
88
92

100
106

Air-entrained
78
83
88
92

100
106

concrete

100
100

REQUIREMENTS FOR

SIZES OF

Water ,

10.0

120

kg/m^3

max. sizes

of

AGGREGATES
of

concrete

coarse

15.0

for

aggregate

indicated
in

20.0

178

169

157

199

193

178

187
208
228
243

187
199
217
228

169
187
199
214

3.0

2.5

2.0

157

148

139

178

169

157

concrete

169
187
202
217
8.0

157
175
193
208

7.0

148
166
178
193

6.0

mm.

Table

A 2.3.4.3

Compressive
at

28

0.44
0.53
0.60
0.65
0.70

strength

days , kgf/cm^2

150
160

3.00

RELATIONSHIPS

170
180
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
350
360
370

380
390
400
410
420
430
440
450
for

egate

460

indicated
in

mm.

470
25.0

40.0

148

139

169

157

157
178
193
208

148
163
178
187

1.5

1.0

133

125

148

139

139
157
178
187

5.0

133
148
157
169

4.5

480
490
500

3.4.3

RELATIONSHIPS BETWEEN WATER - CEMENT

strength

ys , kgf/cm^2

Water - cement

Non-air-entrained

concrete

ratio , by

0.71

0.76

0.67

0.78
0.74
0.70
0.68
0.67
0.65
0.64
0.62
0.61
0.59
0.58
0.56
0.55
0.54
0.52
0.51
0.49
0.48
0.47
0.46

weight

Air-entrained

0.80

0.69
0.65
0.61
0.59
0.58
0.56
0.55
0.53
0.52
0.50
0.49
0.47
0.46
0.45
0.44
0.42
0.41
0.40
0.39
0.38

RATIO

concrete

0.45

0.36

0.43

0.34

0.44
0.42
0.41
0.40
0.39
0.38
0.37
0.36
0.35
0.34
0.33

0.35
0.33
0.32
0.31
0.30
0.29
0.28
0.27
0.26
0.25
0.24

CODE

NAME

10 AA
20 BB

30 CC
40 DD

SALARY

6000
6500
7000
8000

50 EE

15000

40 DD

8000

30

You might also like