You are on page 1of 1

28

29

30
10 # 7

12 # 14 @0-06 V

3-03 (LAP)

2 x 2 #7 12-06 @0-06 V 1/2 EF

2 x 2 #7 12-06 @0-06 V 1/2 EF


2 x 4 9B002 @0-06 V
2 x 4 9B001 @0-06 V

2 x 20 #7 12-06 @1-00 V IF

2 x 20 #7 12-06 @1-00 V IF

2 x 19 #7 12-06 @1-00 V OF

2 x 19 #7 12-06 @1-00 V OF

2 x 2 #7 12-06 @0-06 V 1/2 EF


2 x 4 #14 10-00 @0-06 V

LEVEL P4
EL: 100-00
2 x 20 #7 12-06 @1-00 V OF

1 # 11 DWLS.

2 x 20 #7 12-06 @1-00 V OF

1 # 11 DWLS.

5B002

1 # 11 DWLS.

1 # 11 DWLS.

4 # 14 @0-06 V

FIELD USE:

2 x 4 #14 10-00 @0-06 V

10 # 7

10 # 7

12 #14 @0-06 V
5B002

2-06
#7 LAP (TYP)

6-06 (TYP)

2 x 2 #7 12-06 @0-06 V 1/2 EF

SECTION-C

4 # 14 @0-06 V

SECTION-A

SCALE: 1'-00" = 1/2"

SCALE: 1'-00" = 1/2"

2 x 19 #7 12-06 @1-00 V IF
2 x 19 #7 12-06 @1-00 V IF

10 # 7

4 x 10 7B001 @1-00 COR.


2 x 15 5B001 @0-08 TIES
2 x 10 7B002 @1-00 COR.

2 x 10 7B002 @1-00 INT. EF


2 x 15 5B001 @0-08 TIES
2 x 15 5B001 @0-08 TIES

2 x 10 #7 30-00 @1-00 H IF
2 x 10 #7 30-00 @1-00 H OF
2 x 10 7B002 @1-00 INT. EF

2 x 10 #7 30-00 @1-00 H IF
2 x 10 #7 30-00 @1-00 H OF

42-06

1-00

2 x 10 #7 30-00 @1-00 H IF
2 x 10 #7 30-00 @1-00 H OF

2 x 10 #7 7-06 @1-00 H IF
2 x 10 #7 7-06 @1-00 H OF
4 x 10 7B001 @1-00 COR.

42-06

1-00

2 x 10 7B002 @1-00 COR.


2 x 15 5B001 @0-08 TIES

9B002

9B002

9B001

9B001

1-00

ELEVATION SW 62 & SW 63

9B002

3 x 2 #7 12-06 @0-06 V 1/2 EF

B.2

9B001

7B002

REF : S5-01,S5-02,S5-10,S2.03N THRU S2.09N (DT:11/11/14)


NO OF PLACES : 02
SCALE: 1'-00" = 1/4"

A.8

APPROVAL AUTHORITY:

12 # 14 @0-06 V

LEVEL P3
EL: 90-00

SECTION-B
SCALE: 1'-00" = 1/2"

ALL ITEMS THAT ARE CLOUDED &/OR MARKED "VERIFY"


REFER TO QUESTIONS, OMISSIONS, CONFLICTS OR ERRORS
IN THE CONTRACT DOCUMENTS. UNLESS CORRECTIVE
ACTION IS INDICATED ON THIS APPROVAL ALL ITEMS SO
MARKED WILL BE ASSUMED CORRECT AS SUBMITTED, AND
FURNISHED AS DETAILED.

2-00

6-00 (TYP)

3-03 (TYP)

4-00

10-00

B.5
3 x 2 #7 12-06 @0-06 V 1/2 EF

3 x 6 #7 12-06 @1-00 V IF

FOR:

----

DATE:

LEVEL P3
EL: 90-00

3 x 10 #7 18-07 @1-00 H IF
3 x 10 #7 18-07 @1-00 H OF

16-10

1-00

-----

3 x 15 5B003 @0-08 T9 LINKS


3 x 15 5B003 @0-08 T9 LINKS
3 x 15 5B002 @0-08 TIES

REF:

1-00

DATE:

----DATE:

3 x 15 5B002 @0-08 TIES


3 x 15 5B003 @0-08 T9 LINKS
3 x 15 5B003 @0-08 T9 LINKS

Rev DATE

LEVEL P4
EL: 100-00

Rev DATE

3 x 12 #14 10-00 @0-06 V

3 x 6 #7 12-06 @1-00 V OF

Rev DATE

3 x 12 #14 10-00 @0-06 V

FOR:

3 x 6 #7 12-06 @1-00 V IF

FOR:

SUBMITAL RECORD

3 x 6 #7 12-06 @1-00 V OF

10-00
Qty.

Size

Length

Type

PHONE:

B
9B001

#9

13-11

9-00

1-00

3-11

0-03

1-00

13-11

9B002

#9

13-11

8-10

1-00

4-01

0-03

1-00

13-11

7B001

80

#7

7-07

17

3-03

4-04

7B002

80

#7

8-08

17

4-04

4-04

5B001

120

#5

4-00

T2

0-06

0-09

0-09

0-09

0-09

0-06

5B002

90

#5

8-00

T2

0-06

0-09

2-09

0-09

2-09

0-06

5B003

180

#5

1-08

T9

0-05

0-09

17
D

Qty.

Size

Length

Type

T2

10-00

10-00

#11

11-06

11-06

#11

15-06

15-06

412

#7

12-06

12-06

60

#7

18-07

18-07

120

#7

30-00

30-00

#7
#8
#9
#10
#11

3-03
4-02
5-01
6-03
7-05

2-06
3-02
3-11
4-10
5-09

LEGENDS:
H
V
EF
IF
OF
COR.
DWLS.

HORIZONTALS
VERTICALS
EACH FACE
INNER FACE
OUTERFACE
CORNERS
DOWELS

SW 62

T9

#7

7-06

7-06

G
B

COVER DETAILS
EDGE
INNER FACE
OUTER FACE

0-01 1/2
0-01 1/2
0-01 1/2
SW 63

NOTES:
1. ALL #14 REINFORCING SHOWN IN THIS SHEET IS ASTM A615-75
2. ALL OTHER REINFORCING THIS SHEET IS ASTM A615-60

TOTAL NO
OF BARS
TOTAL WT(LBS)

KEY PLAN
REF.: S2.03N; (DT:11/11/14)
SCALE: 1'-00" = 1/12"

B.5

40

-----

B.2

#14

OTHERS

C
88

TOP

1294
31452.28
JOB #:
DRAWING:

THIS DRAWING IS GENERATED FROM


RGS REBAR BIM - 3D SOFTWARE

SAMPLE

DESCRIPTION:

LAP DETAILS

LOCATION: ------

G
V1

SW 66

SW 65

H
K

BarMark

30
A.8

29

B
J

0-06

28

JOB NAME:

27

CUSTOMER -----

REINF. DETAILS OF AREA N SHEARWALL (P3-P4 LEVEL)

BarMark

EMAIL:

DETAILER: RGS

3-D VIEW FOR SW64 (MIRROR) & SW 66

BAR BENDING SCHEDULE :

JOB #:

PROJECT INFORMATION

REF : S5-01,S5-02,S5-10,S2.03N THRU S2.09N (DT:11/11/14)


NO OF PLACES : 03
SCALE: 1'-00" = 1/4"

-----

ELEVATION SW64, SW 65 & SW 66

SW 64

2-00

6-00 (TYP)

2 x 1 #11 11-06 @0-06 DWLS.


2 x 1 #11 15-06 @0-06 DWLS.

#7 LAP + 4-00 STAG (TYP)

7B002
2 x 1 #11 15-06 @0-06 DWLS.
2 x 1 #11 11-06 @0-06 DWLS.

THIS DRAWING TO BE USED IN CONJUNCTION w/ STRUCTURAL


AND ARCHITECTURAL DOCUMENTS TO FACILITATE PLACING OF
REINFORCING BARS ONLY. DO NOT USE THIS DRAWING FOR
LAYOUT OR CONSTRUCTION, ANY DIMENSIONS OF ELEVATIONS
NOTED IN THIS DOCUMENT ARE FOR REFERENCE ONLY, TO
FACILITATE APPROVAL &/OR PLACEMENT OR REBAR.
DISCREPANCIES SHOULD BE NOTED AT THE TIME OF APPROVAL

27

You might also like