Professional Documents
Culture Documents
Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: FTG-1
Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: FTG-2
v =
Punching
Vt =
v =
Punching
Vt =
v =
0.52 N/mm2
< vc =
0.61 N/mm2
Check (At Column Face): (BS8110-Cl.3.7.6.4)
754.665 kN
V-eff = 873.167 kN
0.61 N/mm2
<
v-max =
3.58 N/mm2
Check (At '1.5d') (BS8110-Cl.3.7.6.4)
531.619 kN
V-eff = 650.121 kN
0.35 N/mm2
<
vc =
0.61 N/mm2
B3
-------------------------------------------------------------------------------Columns:
1C19, 1C11, 1C12
bx =
2855.0 mm
by =
1595.0 mm
Effects:
Critical Combination = 1 (G+Q *F)
N =
-1072.775 kN
Mx =
269.48 kN.m
My =
169.38 kN.m
Footing Dimensions:
Lx =
4755.0 mm
Ly =
3095.0 mm
h =
300.0 mm
h-Tap =
0.0 mm
Soil Stresses:
S-max = 137.185 kN/m2
S-min =
46.349 kN/m2
Allowable Soil Stress will be amplified by the factor (x1.4) =
140.000 kN/m2
As-min (Both Dir's) =
600.0 mm2/m
X Dir:
Footing Design:
M =
60.52 kN.m/m
K/K' =
0.53 < 1.0
As =
983.9 mm2/m
Y16-200
Shear Check (At Column Face): (BS8110-Cl.3.4.5.2)
v =
0.68 N/mm2
< v-max =
3.58 N/mm2
Shear Check (At 'd' from Column): (BS8110-Cl.3.4.5.2)
v =
0.54 N/mm2
< vc =
0.61 N/mm2
Punching Check (At Column Face): (BS8110-Cl.3.7.6.4)
Vt = 932.625 kN
V-eff = 1120.899 kN
v =
0.68 N/mm2
<
v-max =
3.58 N/mm2
Punching Check (At '1.5d'): (BS8110-Cl.3.7.6.4)
Vt = 679.247 kN
V-eff = 867.522 kN
v =
0.42 N/mm2
<
vc =
0.61 N/mm2
Y Dir:
Footing Design:
M =
37.57 kN.m/m
K/K' =
0.39 < 1.0
As =
645.6 mm2/m
Y16-250
Shear Check (At Column Face): (BS8110-Cl.3.4.5.2)
v =
0.58 N/mm2
< v-max =
3.58 N/mm2
Shear Check (At 'd' from Column): (BS8110-Cl.3.4.5.2)
v =
0.45 N/mm2
< vc =
0.60 N/mm2
Punching Check (At Column Face): (BS8110-Cl.3.7.6.4)
Vt = 932.625 kN
V-eff = 1120.899 kN
v =
0.68 N/mm2
<
v-max =
3.58 N/mm2
Punching Check (At '1.5d') (BS8110-Cl.3.7.6.4)
Vt = 679.247 kN
V-eff = 753.820 kN
v =
0.37 N/mm2
<
vc =
0.60 N/mm2
B4
-------------------------------------------------------------------------------Columns:
1C13, 1C14, 1C15, 1C22
bx =
3085.0 mm
by =
2855.0 mm
Effects:
Critical Combination = 3 ((G+Q)P12 *F)
N =
-1129.994 kN
Mx =
0.00 kN.m
My =
221.73 kN.m
Footing Dimensions:
Lx =
3685.0 mm
Ly =
3500.0 mm
h =
400.0 mm
h-Tap =
0.0 mm
Soil Stresses:
S-max = 135.598 kN/m2
S-min =
76.653 kN/m2
Allowable Soil Stress will be amplified by the factor (x1.4) =
140.000 kN/m2
As-min (Both Dir's) =
800.0 mm2/m
X Dir:
Footing Design:
M =
6.10 kN.m/m
K/K' =
0.02 < 1.0
As =
800.0 mm2/m
Y16-175
Shear Check (At Column Face): (BS8110-Cl.3.4.5.2)
v =
0.14 N/mm2
< v-max =
3.58 N/mm2
Shear Check (At 'd' from Column): (BS8110-Cl.3.4.5.2)
v =
0.00 N/mm2
< vc =
0.50 N/mm2
Punching Check (At Column Face): (BS8110-Cl.3.7.6.4)
Vt = 434.036 kN
V-eff = 524.293 kN
v =
0.16 N/mm2
<
v-max =
3.58 N/mm2
Punching Check (At '1.5d'): (BS8110-Cl.3.7.6.4)
Vt =
0.000 kN
V-eff =
0.000 kN
v =
0.00 N/mm2
<
vc =
0.50 N/mm2
Y Dir:
Footing Design:
M =
6.96 kN.m/m
K/K' =
0.03 < 1.0
Project: NEW
Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: FTG-3
As =
800.0 mm2/m
Y16-175
Shear Check (At Column Face): (BS8110-Cl.3.4.5.2)
v =
0.16 N/mm2
< v-max =
3.58 N/mm2
Shear Check (At 'd' from Column): (BS8110-Cl.3.4.5.2)
v =
0.02 N/mm2
< vc =
0.52 N/mm2
Punching Check (At Column Face): (BS8110-Cl.3.7.6.4)
Vt = 434.036 kN
V-eff = 524.293 kN
v =
0.16 N/mm2
<
v-max =
3.58 N/mm2
Punching Check (At '1.5d') (BS8110-Cl.3.7.6.4)
Vt =
0.000 kN
V-eff =
0.000 kN
v =
0.00 N/mm2
<
vc =
0.52 N/mm2
B6
-------------------------------------------------------------------------------Columns:
1C26, 1C31
bx =
225.0 mm
by =
1585.0 mm
Effects:
Critical Combination = 1 (G+Q *F)
N =
-755.430 kN
Mx =
0.00 kN.m
My =
190.30 kN.m
Footing Dimensions:
Lx =
2100.0 mm
Ly =
4185.0 mm
h =
400.0 mm
h-Tap =
0.0 mm
Soil Stresses:
S-max = 138.983 kN/m2
S-min =
76.892 kN/m2
Allowable Soil Stress will be amplified by the factor (x1.4) =
140.000 kN/m2
As-min (Both Dir's) =
800.0 mm2/m
X Dir:
Footing Design:
M =
61.08 kN.m/m
K/K' =
0.26 < 1.0
As =
800.0 mm2/m
Y16-250
Shear Check (At Column Face): (BS8110-Cl.3.4.5.2)
v =
0.47 N/mm2
< v-max =
3.58 N/mm2
Shear Check (At 'd' from Column): (BS8110-Cl.3.4.5.2)
v =
0.33 N/mm2
< vc =
0.46 N/mm2
Punching Check (At Column Face): (BS8110-Cl.3.7.6.4)
Vt = 910.115 kN
V-eff = 1175.156 kN
v =
1.14 N/mm2
<
v-max =
3.58 N/mm2
Punching Check (At '1.5d'): (BS8110-Cl.3.7.6.4)
Vt = 665.310 kN
V-eff = 665.313 kN
v =
0.33 N/mm2
<
vc =
0.46 N/mm2
Y Dir:
Footing Design:
M =
112.01 kN.m/m
K/K' =
0.42 < 1.0
As =
1168.5 mm2/m
Y16-150
Shear Check (At Column Face): (BS8110-Cl.3.4.5.2)
v =
0.62 N/mm2
< v-max =
3.58 N/mm2
Shear Check (At 'd' from Column): (BS8110-Cl.3.4.5.2)
v =
0.48 N/mm2
< vc =
0.51 N/mm2
Punching Check (At Column Face): (BS8110-Cl.3.7.6.4)
Vt = 910.115 kN
V-eff = 1175.156 kN
v =
1.14 N/mm2
<
v-max =
3.58 N/mm2
Punching Check (At '1.5d') (BS8110-Cl.3.7.6.4)
Vt = 665.310 kN
V-eff = 930.351 kN
v =
0.47 N/mm2
<
vc =
0.51 N/mm2
B5
-------------------------------------------------------------------------------Columns:
1C23, 1C24, 1C25
bx =
5185.0 mm
by =
225.0 mm
Effects:
Critical Combination = 5 ((G+Q)P22 *F)
N =
-617.787 kN
Mx =
649.49 kN.m
My =
0.00 kN.m
Footing Dimensions:
Lx =
5585.0 mm
Ly =
2000.0 mm
h =
400.0 mm
h-Tap =
0.0 mm
Soil Stresses:
S-max = 139.411 kN/m2
S-min =
14.476 kN/m2
Allowable Soil Stress will be amplified by the factor (x1.4) =
140.000 kN/m2
As-min (Both Dir's) =
800.0 mm2/m
X Dir:
Footing Design:
M =
2.76 kN.m/m
K/K' =
0.01 < 1.0
As =
800.0 mm2/m
Y16-250
Shear Check (At Column Face): (BS8110-Cl.3.4.5.2)
v =
0.10 N/mm2
< v-max =
3.58 N/mm2
Shear Check (At 'd' from Column): (BS8110-Cl.3.4.5.2)
v =
0.00 N/mm2
< vc =
0.44 N/mm2
Punching Check (At Column Face): (BS8110-Cl.3.7.6.4)
Vt = 769.696 kN
V-eff = 1674.284 kN
v =
0.54 N/mm2
<
v-max =
3.58 N/mm2
Punching Check (At '1.5d'): (BS8110-Cl.3.7.6.4)
Project: NEW
Y Dir:
Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: FTG-4
Vt = 396.641 kN
V-eff = 1301.229 kN
v =
0.34 N/mm2
<
vc =
0.44 N/mm2
Footing Design:
M =
54.90 kN.m/m
K/K' =
0.23 < 1.0
As =
800.0 mm2/m
Y16-175
Shear Check (At Column Face): (BS8110-Cl.3.4.5.2)
v =
0.45 N/mm2
< v-max =
3.58 N/mm2
Shear Check (At 'd' from Column): (BS8110-Cl.3.4.5.2)
v =
0.31 N/mm2
< vc =
0.52 N/mm2
Punching Check (At Column Face): (BS8110-Cl.3.7.6.4)
Vt = 769.696 kN
V-eff = 1674.284 kN
v =
0.54 N/mm2
<
v-max =
3.58 N/mm2
Punching Check (At '1.5d') (BS8110-Cl.3.7.6.4)
Vt = 396.641 kN
V-eff = 396.642 kN
v =
0.10 N/mm2
<
vc =
0.52 N/mm2
B7
-------------------------------------------------------------------------------Columns:
1C32, 1C33, 1C34
bx =
3085.0 mm
by =
225.0 mm
Effects:
Critical Combination = 4 ((G+Q)P21 *F)
N =
-960.263 kN
Mx =
183.91 kN.m
My =
0.00 kN.m
Footing Dimensions:
Lx =
5085.0 mm
Ly =
2000.0 mm
h =
400.0 mm
h-Tap =
0.0 mm
Soil Stresses:
S-max = 137.591 kN/m2
S-min =
94.915 kN/m2
Allowable Soil Stress will be amplified by the factor (x1.4) =
140.000 kN/m2
As-min (Both Dir's) =
800.0 mm2/m
X Dir:
Footing Design:
M =
67.40 kN.m/m
K/K' =
0.26 < 1.0
As =
800.0 mm2/m
Y20-250
Shear Check (At Column Face): (BS8110-Cl.3.4.5.2)
v =
0.47 N/mm2
< v-max =
3.58 N/mm2
Shear Check (At 'd' from Column): (BS8110-Cl.3.4.5.2)
v =
0.34 N/mm2
< vc =
0.52 N/mm2
Punching Check (At Column Face): (BS8110-Cl.3.7.6.4)
Vt = 1101.595 kN
V-eff = 1359.891 kN
v =
0.73 N/mm2
<
v-max =
3.58 N/mm2
Punching Check (At '1.5d'): (BS8110-Cl.3.7.6.4)
Vt = 694.597 kN
V-eff = 952.893 kN
v =
0.34 N/mm2
<
vc =
0.52 N/mm2
Y Dir:
Footing Design:
M =
54.19 kN.m/m
K/K' =
0.23 < 1.0
As =
800.0 mm2/m
Y16-150
Shear Check (At Column Face): (BS8110-Cl.3.4.5.2)
v =
0.45 N/mm2
< v-max =
3.58 N/mm2
Shear Check (At 'd' from Column): (BS8110-Cl.3.4.5.2)
v =
0.31 N/mm2
< vc =
0.55 N/mm2
Punching Check (At Column Face): (BS8110-Cl.3.7.6.4)
Vt = 1101.595 kN
V-eff = 1359.891 kN
v =
0.73 N/mm2
<
v-max =
3.58 N/mm2
Punching Check (At '1.5d') (BS8110-Cl.3.7.6.4)
Vt = 694.597 kN
V-eff = 694.598 kN
v =
0.25 N/mm2
<
vc =
0.55 N/mm2
B8
-------------------------------------------------------------------------------Columns:
1C36, 1C39, 1C42
bx =
1355.0 mm
by =
2255.0 mm
Effects:
Critical Combination = 1 (G+Q *F)
N =
-537.841 kN
Mx =
33.90 kN.m
My =
315.00 kN.m
Footing Dimensions:
Lx =
2455.0 mm
Ly =
3855.0 mm
h =
400.0 mm
h-Tap =
0.0 mm
Soil Stresses:
S-max = 137.845 kN/m2
S-min =
16.729 kN/m2
Allowable Soil Stress will be amplified by the factor (x1.4) =
140.000 kN/m2
As-min (Both Dir's) =
800.0 mm2/m
X Dir:
Footing Design:
M =
20.65 kN.m/m
K/K' =
0.09 < 1.0
As =
800.0 mm2/m
Y16-250
Shear Check (At Column Face): (BS8110-Cl.3.4.5.2)
v =
0.27 N/mm2
< v-max =
3.58 N/mm2
Shear Check (At 'd' from Column): (BS8110-Cl.3.4.5.2)
v =
0.14 N/mm2
< vc =
0.46 N/mm2
Project: NEW
Y Dir:
Welly76**********************7 (11111111)
Orion Building Design System 15.1 (01.2009) / Page: FTG-5
Punching Check (At Column Face): (BS8110-Cl.3.7.6.4)
Vt = 495.292 kN
V-eff = 709.386 kN
v =
0.35 N/mm2
<
v-max =
3.58 N/mm2
Punching Check (At '1.5d'): (BS8110-Cl.3.7.6.4)
Vt = 201.477 kN
V-eff = 217.842 kN
v =
0.07 N/mm2
<
vc =
0.46 N/mm2
Footing Design:
M =
41.82 kN.m/m
K/K' =
0.16 < 1.0
As =
800.0 mm2/m
Y16-250
Shear Check (At Column Face): (BS8110-Cl.3.4.5.2)
v =
0.38 N/mm2
< v-max =
3.58 N/mm2
Shear Check (At 'd' from Column): (BS8110-Cl.3.4.5.2)
v =
0.24 N/mm2
< vc =
0.44 N/mm2
Punching Check (At Column Face): (BS8110-Cl.3.7.6.4)
Vt = 495.292 kN
V-eff = 709.386 kN
v =
0.35 N/mm2
<
v-max =
3.58 N/mm2
Punching Check (At '1.5d') (BS8110-Cl.3.7.6.4)
Vt = 201.477 kN
V-eff = 415.571 kN
v =
0.14 N/mm2
<
vc =
0.44 N/mm2
B9
-------------------------------------------------------------------------------Columns:
1C43, 1C48
bx =
225.0 mm
by =
1805.0 mm
Effects:
Critical Combination = 1 (G+Q *F)
N =
-684.174 kN
Mx =
0.00 kN.m
My =
418.01 kN.m
Footing Dimensions:
Lx =
2200.0 mm
Ly =
4805.0 mm
h =
450.0 mm
h-Tap =
0.0 mm
Soil Stresses:
S-max = 137.247 kN/m2
S-min =
38.490 kN/m2
Allowable Soil Stress will be amplified by the factor (x1.4) =
140.000 kN/m2
As-min (Both Dir's) =
900.0 mm2/m
X Dir:
Footing Design:
M =
66.92 kN.m/m
K/K' =
0.21 < 1.0
As =
900.0 mm2/m
Y16-200
Shear Check (At Column Face): (BS8110-Cl.3.4.5.2)
v =
0.42 N/mm2
< v-max =
3.58 N/mm2
Shear Check (At 'd' from Column): (BS8110-Cl.3.4.5.2)
v =
0.28 N/mm2
< vc =
0.44 N/mm2
Punching Check (At Column Face): (BS8110-Cl.3.7.6.4)
Vt = 893.170 kN
V-eff = 1407.964 kN
v =
1.05 N/mm2
<
v-max =
3.58 N/mm2
Punching Check (At '1.5d'): (BS8110-Cl.3.7.6.4)
Vt = 629.403 kN
V-eff = 629.405 kN
v =
0.24 N/mm2
<
vc =
0.44 N/mm2
Y Dir:
Footing Design:
M =
142.84 kN.m/m
K/K' =
0.40 < 1.0
As =
1272.8 mm2/m
Y20-200
Shear Check (At Column Face): (BS8110-Cl.3.4.5.2)
v =
0.61 N/mm2
< v-max =
3.58 N/mm2
Shear Check (At 'd' from Column): (BS8110-Cl.3.4.5.2)
v =
0.47 N/mm2
< vc =
0.48 N/mm2
Punching Check (At Column Face): (BS8110-Cl.3.7.6.4)
Vt = 893.170 kN
V-eff = 1407.964 kN
v =
1.05 N/mm2
<
v-max =
3.58 N/mm2
Punching Check (At '1.5d') (BS8110-Cl.3.7.6.4)
Vt = 629.403 kN
V-eff = 1144.198 kN
v =
0.43 N/mm2
<
vc =
0.48 N/mm2
Project: NEW