VIKRAM UDYOGPURI LIMITED, UJJAIN, MADHYA PRADESH

SPML - OM METALS (JV)

9.3 Design of Footing as beam for Lifting case:

0.10

0.5125

0.25

0.5125

Precast footing at the time of lifting will behave as simply supported beam subjected to its self weight.
Concrete grade of column

Consider the age of concrete at the time of lifting as

Consider Strength of concrete at 7 Days is

12 Mpa

Reinforcing steel grade

500 Mpa

Width of Footing is

925 mm

Depth of footing is middle portion =

100 mm

Depth of footing at edge portion =

400 mm

Maximum Bending Moment =

0.82 kNm

Maximum Shear Force =

5.03 kN

Ultimate Bending Moment Mu =

1.23 kNm

Ultimate Shear Force Vu =

Depth at Maximum Bending Moment =

100 mm

Clear cover to reinforcement =

50 mm

Effective depth

45 mm

2.99 kNm

67 mm

363 mm

Udl (kN/m)

9.25

2.31

60%

20 Mpa
7 Days

9.25

1.075
Reaction (kN) 5.03

Mbal =
Ast required =

5.03

0.133*fck*b*d^2
2

0.5 fck / fy x (1-sqrt(1-(4.6 Mu/ fck b d ))) b d

Provided reinforcement is

Y 10 Dia

@ 200 in Width of 925 mm

7.545 kN

Safe
Shear stress due to shear force v =
Shear capacity of concrete

( 7.545 x 1000) / (925 x (400 - 50 - 5) )=

(Pt = 0.114%)

c =

2
0.024 N/mm

0.28 N/mm2
Safe

Sanguine Infra Tech Pvt.Ltd., Mumbai

Page | 20