[MANUAL_ RUGOSMETRO]
CONTENT
CONTENIDO
1. - General Introduction
.3
1. - Introduccin general
............................... 3
2.-Work Principle
.4
............................... 4
.5
.............................. 5
4.-Operational Measure
.7
4 -. Medida Operacional
............................... 7
5.1.-Measurement preparation
.7
............................... 7
.8
............................... 8
5.3-Selecting Parameters
.8
.............................. 8
5.4 Measuring
.9
5.4 Medicin
............................... 9
5.5 Calibration
.10
5.5 Calibracin
............................. 10
.11
5.6-Recarga de la batera
............................ 11
6.-Daily Maintenance
.11
6 - Mantenimiento diario
............................ 11
6.1- Maintenance
.11
6.1-Mantenimiento
............................. 11
6.2- Repair
.12
6.2-Reparacion
............................. 12
7.-Terminology Definition
.12
............................. 12
8. - User Notes
.15
............................ 15
2.-Work Principle
Supporting Plate
Calibrate Sample
Testing Area
Reset
Start
USB
Display Area
Function Key
Power Key
Sliding Key
Measuring Area
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
Placa de soporte
Calibrar Muestra
rea de pruebas
Restablecer
Empezar
USB
rea de visualizacin
Tecla de funcin
Tecla de encendido
Chaveta deslizante
rea o de medicin
4.-Technical Parameters
4 -. Parmetros tcnicos
Measurement Parameters () =
Stroke Length () = 6
Sampling Length () = 0.24 , 0.80. 2.50
Evaluation Length () = 1.25, 4.0
Measurement Range () =
, = 0.05~10.0
, = 0.1~50
The sensor touch needle static force measurement and its rate
Touch needle static force measurement 0.016
5. - Operational Measure
5.1 Measurement Preparation
5. - Medida Operacional
5.1 Preparacin de la medicin
Remove instrument, right now the sensors head protect door should be
closed. ( See Illustration below)
To the right to promote measuring head protect door switch, open the
sensors head protect door, Show the sensors head prepared
measurement
5.2
Button
a second boot, after a voice of di, going into
measurement state. Mearsuring parameters and sampling length will
keep the last time before the shutdown of the state.
Boot Condition,
Buttons a second shutdown. The instrument
will go into the low consumption status. In 3 minutes, without
buttoning, the operating instruments will be turned off.
Botn
de un segundo arranque, despus de una voz de (sonido di),
entrando en estado de medicin.
Los parmetros de medicin y longitud de muestreo se mantendrn
visibles hasta el momento de reiniciar el equipo.
Condicin de arranque,
botones una segunda parada. El
instrumento entrar en el estado de bajo consumo. En 3 minutos, sin
tocar un botn, los instrumentos operativos se desactivarn.
0.8 mm y 2.5 mm
5.4 Measuring
5.4 Medicin
When the parameters are set up and the cut-off samples length is
decided, it will come to measurement. Point the Stylus Mark to the
measured area stably and then press the Start Key on the top to start
measurement, liquid crystal display as Waiting At this time, it will be
invalid to press the start button
After the Waiting disappeared with two d.d, the measurement has
being finished, and the screen will show the measured value
Note
Nota
Before use, calibration should be done with the standard sample plate.
For example, there is a standard plate pointed to 3.14.In shutdown
condition, press the start button boots, As shown below, release the
start button. The tester will enter the status of calibration
5.5 Calibracin
Antes de su uso, la calibracin debe realizarse con la placa de muestra
estndar. Por ejemplo, hay una placa estndar sealada a 3,14. En
condicin de parada, pulse el botn de arranque, como se muestra a
continuacin, suelte el botn de arranque. El probador establecer en
el estado de la calibracin
Press the Up Key and Down Key to adjust the displaying value to the
value 3.14.
Pulse la tecla Arriba y Abajo para ajustar el valor que muestra el valor
3,14.
5.5 Calibration
Plug the charger into testers recharge socket and have the tester
recharge together with the battery symbol lighting (if no lighting, plug it
again). 3 hours recharging-time is enough.
Filled animation end. Even in shout down condition may also start
charging interface display
6.-Daily Maintenance
6.1 Maintenance
6.1 Mantenimiento
6.2 Repair
6.2 Reparacin
If any trouble occurs, user should not try to dismantle and repair it. The
device should be returned to the manufacturer for checking and repair,
together with the warranty card and the specimen provided and a
statement about the trouble .Please keep in constant touch with the
marketing department of our company or our sales agents.
7. Terminology Definition
o Surface Roughness is the microcosmic geometric form on the
work-piece surface composed by peak and valley with small
interspaces
o Sample Length is the benchmarks length used to be
distinguished its surface roughness
o Evaluation Length is the necessary length for evaluating the
roughness profile. It may include one or more sampling lengths.
o Ra Arithmetical Mean Deviation of the profile is arithmetic mean
value of the deviation of the profile within sampling length
o Rz The maximum height of Irregularities is the distance
between maximum depth of the profile peaks and maximum
depth of the profile valley within the sampling length
o Rq Root mean square Deviation of Profile Rq is the square
root of the arithmetic mean of the squares of profile
deviation(YI) from mean within sampling length
o Rt Total Peak-to-valley Height Rt is the sum of the height of the
highest peak and the depth of the deepest valley over the
evaluation length
7. Definicin de Terminologa
Rugosidad de la superficie es la forma microgeomtrica de la
superficie de la pieza de trabajo compuesta por picos y valles
con pequeos espacios intermedios
Longitud de Muestra es la longitud del ndice de referencia
utilizado para distinguirse de su rugosidad superficial
Longitud de Evaluacin es la longitud necesaria para la
evaluacin del perfil de rugosidad. Se puede incluir una o ms
longitudes de muestreo.
Desviacin Ra media aritmtica del perfil de valor es la media
aritmtica de la desviacin del perfil dentro de la longitud de
muestreo
Rz La altura mxima de las irregularidades es la distancia entre
la profundidad mxima de los picos del perfil y la profundidad
mxima del valle perfil dentro de la longitud de muestreo
Rq Root- media cuadrtica desviacin del perfil de Rq es la raz
cuadrada de la media aritmtica de los cuadrados de la
desviacin del perfil (YI) de media dentro de la longitud de
muestreo
Rt Altura total de pico a valle Rt es la suma de la altura del pico
ms alto y la profundidad del valle ms profundo sobre la
longitud de evaluacin
= =1|1 |
1
= ( 1 2 )
=1
1
2
8.-User Notes
Users buy our products. Please fill in < warranty card > and affixed to
the user unit seal. After that, Put them and invoice copy to send to the
company. You can also entrust sale machine unit with send. If the
formalities isnt full, only maintenance cannot guarantee