Date :22-03-2016

ANTI-STATIC TEST REPORT


Customer

M/s Gail India Limited

PO No.

:G

Project

AIL /

4-0 46 / 019 / 5200 00 4487 / C-15 / 07 0 D ated:Is / 70

/ 2015

Cujarat Pipeline Replacement Project

This is to certify that the following Valves have been carried out anti-static test as per API 6D and As per
Apprd. QAP

Item
No. of

Description

4ry.

Valve Sr. No.

Observation

03 Nos.

H803140 toHB03142

Satisfactory

02 Nos.

H803143 & HB031414

Satisfactory

13 Nos.

HB03145 to HB03157

Satisfactory

05 Nos.

HB03158 to HB03162

Satisfactory

02 Nos.

H803163 & HB03164

Satisfactory

MR
400 mm (16") Ball Valve 2Pc Design 600# Class
1

Reduced Bore Flange End - WCB with Gear

Operated
400 mm (16") Ball Valve 2Pc Design 600# Class
2

Reduced Bore Butt Weld End - WCB with Gear

Operated
300

mm (12") Ball Valve 2Pc Design 600# Class

Reduced Bore Butt Weld End - WCB with Gear

Operated
150 mm (6") Ball Valve 2Pc Design 300# Class
4

Reduced Bore Flange End - WCB with Gear

Operated
150 mm (6") Ball Valve 2Pc Design 300# Class
5

Reduced Bore Butt Weld End - WCB with Gear

Operated

Test Result: The electrical resistance between the obturator and the valve body and between the stem/shaft and the
valve body have been measured before pressure testing and does not found exceed 10 Q. And found Satisfactory.

o