NOTE:
The minimum free area of a chute should be calculated on the
basis of a velocity of 1 m/sec, and the chute being 25% full for
powdery material and 50% full for lumpy material:
FORMULA :
A=
Q*100
3600 * V *F
(m)
where:
Q = Volume flow rate (m/h)
v = Velocity (m/s)
A = Cross-sectional area (m)
F = Filling percent
Step 1:
300
t/h
Enter Density
1.4
t/m
Enter velocity
m/sec
Select Material
clinker
Filling percent
50
Crossectional Area
0.119
m
Step 2:
Choose the nearest standard diameter size for the corresponding c/s area from the standard table :
CHUTE DIA.
( mm.)
0.3893025624
389
0.0729
AREA
( m)
0.119
214.28571
0.1225
---Select--Powdery
Lumpy
Formula
0.119048