Chute Diameter Calculation

NOTE:
The minimum free area of a chute should be calculated on the
basis of a velocity of 1 m/sec, and the chute being 25% full for
powdery material and 50% full for lumpy material:
FORMULA :

A=

Q*100
3600 * V *F

(m)

where:
Q = Volume flow rate (m/h)
v = Velocity (m/s)
A = Cross-sectional area (m)
F = Filling percent
Step 1:

Enter the values in the blank space

Enter Design capacity

300

t/h

Enter Density

1.4

t/m

Enter velocity

m/sec

Select Material

clinker

Filling percent

50

Crossectional Area

0.119
m

Step 2:

Choose the nearest standard diameter size for the corresponding c/s area from the standard table :
CHUTE DIA.
( mm.)
0.3893025624
389
0.0729

AREA
( m)
0.119

214.28571

0.1225

rea from the standard table :