Main duct

Support bend

Blanket insulation
with vapor seal
Stainless steel worm
drive clamp or nylon
strap (per specs)

when activated by
fire alarm system to
protect the duct
penetration.
Typical combination
fire smoke damper

150

Finished ceiling

Sponge rubber gasket all


around

Stainless steel wormdrive


clamp or nylon strap
(per specs)

Blanket insulation
with vapor seal

Scale NTS

11

3.
4.
5.

Manual volume damper


with loacking quadrant
(where required)

Bar grille or slot


diffuser

6.

7.

R = flexible diameter or use

Manual volume damper


with locking quadrant
(where required)

Slot linear
diffuser or grille

50 x 50 angle bar
plenum support

Note:
1. All dimensions are in millimeters
unless otherwise noted.

Transfer Opening at Ceiling Void Details

1.
2.

Blanket insulation
wtih vapor seal
False ceiling

Set screw

10

GENERAL NOTES

Blanket insulation
with vapor seal

Angle bar
plenum support

All threaded rod


plenum support

Exhaust or return Air


grille

Supply duct

Plenum box with


Internal duct insulation
board

Stainless steel worm


drive clamp or nylon
strap (per specs)

Varies

Above ceiling
wall

Supply duct

Acoustic flexible duct,


max.Length = 1500.

100
Min

Fusible link and


spring act to close
damper when
temperatures

All threaded rod


plenum support
Acoustic flexible duct,

This Drawing is not to be scaled.


All dimensions shown are in millimeters and do not take into
account applied finishes unless specifically indicated otherwise.
Any omissions or discrepancies found shall be reported to the
Architect / Engineer immediately.
Levels are given in meters to three decimal places above survey
datum.
This drawing is to be read in conjunction with the relevant section
of the specification and schedules.
The contractor shall submit full shop / setting out drawing for
approval (based on site dimensions) prior to commencement of
any site works, placing of orders, manufacture of fittings, fixtures
and components.
For External Finishes refer to Landscape Drawings and
Specifications.

KEY PLAN

Plenum box with 25 thk.


Internal duct insulation
board 24kg./m3

Exhaust / Return Grille Connection Detail

Side Grille / Slot Diffuser Detail

12

Scale NTS

Ceiling Slot Diffuser Detail

13

Scale NTS

Scale NTS

ZONE-A

Access panel

Sash lock

Duct

Mounting frame
Panel is duct gauge (min)
w/ screw@200 max spacing
Viewport if specified
Metal screw (typ.)

Detail "A"
Volume damper

Access door lock

Distributing grid

Duct
Insulation
Hinges
25 neoprane coated
fiberglass insulation

Access door
handle

Duct ring (typ)

Metal gage

No. Of
Locks

Frame

Rod continuous on

Door

Back

500 Pa
Static
And less

305x305
406x508
610x610

2
2
3

1-S
2-S
2-S

0.70
0.85
0.85

0.55
0.70
0.85

0.55
0.55
0.55

750 Pa.
Static

305x305
406x508
610x610

2
2
3

1-S
1-S,1-T,1-B
2-S,1-T,1-B

0.85
1.00
1.00

0.85
1.00
1.00

0.55
0.55
0.70

1000 Pa
To
2500 Pa

305x305
406x508
610x610

2
3
3

1-S,1-T,1-B
2-S,1-T,1-B
2-S,2-T,2-B

1.00
1.00
1.31

1.00
1.31
1.31

0.55
0.70
0.70

S = side opposite hinges, T = top, B = bottom


Frame 2 hinges
pos.2

Ceiling line

Plan

Ceiling diffuser

Air duct

Round damper

REVISIONS

Up to 450

3 clearance
all around

No. DATE

DESCRIPTION

C0

CONSTRUCTION ISSUE

15-06-15

BY
DA

Elevation Two blade arrangement


475 to 1200

9
quadrant

12
quadrant

Duct

22 Ga. Blade

16 Ga. Blade

Stiffen as required

Gasket

300x300 accesss
door(min.)

FINISH FLOOR LEVEL +0.480 = F.F.L. +8.40 ON SITE

Inside end
bearing

Arm

Door A

See detail "A"

25 neoprane coated
fiberglass insulation

Wing nut

3 clearance
all around

Note:
Over 150 high, use
multiple blades.

Duct

300x300 accesss
door(min.)

Bearing
option
Outside end
bearing

duct

Frame 3 hinges
pos.3
Sponge rubber
gasket all around

Duct
alldampers over

150 (max.)

Lock type 1

No. Of
Hinges

Door size

DESIGN ARCHITECTS & MEP ENGINEERS

Godwin Austen Johnson


Architects

12

300x300 access
door(Alum.)

Butt hinge 25x25 or


piano hinge

Duct depth

Duct branch

ZONE-B

Frames hinges pos.1

Set screw (typ.)

Side elevation

Lock type 2
Frame 2

STRUCTURAL ENGINEERS

Door B
Elevation

14

25wx3 thk.
Access door handle

Round Ceiling Diffuser Connection

15

Scale NTS

Duct

Square Duct Access Door

16

Scale NTS

Volume Damper Detail (Single Blade Type)


Scale NTS

OWNER

Adjustment level
Duct insulation
Min. clearance
all around
Blade lock
Stainless steel
negator closure
spring

Spring vibration isolator


(typ.)

Blade connector

400x400
Access door
Metal screw
@ 150 O.C.

Note:
1. damper to be installed with points facing
downward, and with access from above.
2. verify installation with vendor.

Supply duct

Blade connector

14 Ga. min.
duct sleeve

metal screw
(typ)

Fill with an
approved fire
rated sealant
6 | x 20 Long
bolt w/ nuts @
200 O.C.

25mm acoustic lining for min.


5 meter of duct length in all
directions

Linkage clevis

Opening indicator

attachment hole
(typ)

Fire damper w/ fusible link,


ul 555 installation in
accordance w/ NFPA 90 A

FORTES HOLDING

25mm Acoustically Lined Plenum


Duct (for duct
size see plan)

Damper

Hat channel

38x38x4 Galv.
iron angle bar

Galv. Hanger rods to


structure above (four point)

Duct insulations

Close

Open

Galvanized iron duct

Hat channel

AIR

4 | Metal screw @
250 O.C. all around

Attachment
hole (typical)

Insulation (typ)

ISSUED FOR

CONSTRUCTION
PROJECT

JVT SCHOOL
Plot No. JVT05SCP001
Jumeirah Village Triangle, Dubai, UAE
DRAWING TITLE

Flex conn. (typ)

G.I. sheet duct

MECHANICAL SERVICES
VENTILATION SYSTEM
TYPICAL DETAILS, Sheet 2 OF 3

Condensate to drain as indicated


on the drawings.
Drawn

Insulations

Elevation

G.I sheet duct

Date

RT
14.06.2015

Project No.

Section

Zone

3350
Authority Dwg. No.

17

Duct through Floor Slab with Fire Damper


Scale NTS

18

Volume damper Detail (Parallel Blade)


Scale NTS

19

Volume damper Detail (Opposed Blade)


Scale NTS

20

Fan Coil Unit Detail


Scale NTS

Checked
Scale

EL

Approved

OP

N.T.S.@A1

Drawing No.

A57-501-2

Rev.

C0
Consecutive No.

This drawing, the designs and details shown are the copyright of
GODWIN AUSTEN JOHNSON and shall not be copied or reproduced in
any form without their written consent.
T +971 4 3237555 E mail@gaj-uae.ae
F +971 4 3237717 W www.gaj-uae.ae
PO Box 7185 Dubai United Arab Emirates

A1

Original Sheet FILE PATH : F:\- PROJECTS CURRENT\3350 - Fortes School\LIVE\ACAD\MEP DEPT\Sheet Files\Mechanical\57-Ventilation\3350-A57-502_2.dwg
Size

You might also like