GRUNDFOS DATA BOOKLET

PACO KP, KPV


Split case pump

60 Hz

PACO KP, KPV

Table of contents

1.
2.

3.
4.

5.

6.

Features and benefits

Nameplate

Applications

Commercial systems
Industrial systems
Water distribution
Irrigation and aquaculture

4
4
4
4

Product range

Pump configurations

Performance range

KP 2-pole
KP 4-pole
KP 6-pole

6
7
8

Construction

KP pump, construction X2
KP pump, construction X4
KP pump, construction X5 and X7
KP pump, construction XK and XV
KP pump, typical end view - Horizontal
Std. components and material specification
Mechanical construction

9
10
11
12
13
14
15

Operating conditions

18

Ambient temperature and altitude


Liquid temperatures and shaft seals
Shaft seal
Pressure
Flow
KP Impeller Max Sphere Size
KP model number and construction code

18
18
18
18
19
19
20

7.

8.

Curve charts and technical data

21

How to read the curve charts


Curve conditions
Performance tests
Witness test
KP 2095-1/2 [2-pole]
KP 3095-7/8 [2-pole]
KP 4012-1/2 [2-pole]
KP 4012-7/8 [2-pole]
KP 2095-1/2 [4-pole]
KP 2013-5/6 [4-pole]
KP 3095-7/8 [4-pole]
KP 3014-7/8 [4-pole]
KP 4012-1/2 [4-pole]
KP 4012-7/8 [4-pole]
KP 4015-9/0 [4-pole]
KP 5012-7/8 [4-pole]
KP 5015-9/0 [4-pole]
KP 6012-3/4 [4-pole]
KP 6015-3/4 [4-pole]
KP 6019-7/8 [4-pole]
KP 6020-3/4 [4-pole]
KP 8012-5/6 [4-pole]
KP 8015-3/4 [4-pole]
KP 8020-5/6 [4-pole]
KP 1012-1/2 [4-pole]
KP 1015-3/4 [4-pole]
KP 1020-3/4 [4-pole]
KP 1024-3/4 [4-pole]
KP 1415-1/2 [4-pole]
KP 6019-7/8 [6-pole]
KP 6020-3/4 [6-pole]
KP 8015-3/4 [6-pole]
KP 8020-5/6 [6-pole]
KP 1012-1/2 [6-pole]
KP 1015-3/4 [6-pole]
KP 1020-3/4 [6-pole]
KP 1024-3/4 [6-pole]
KP 1220-5/6 [6-pole]
KP 1415-1/2 [6-pole]

21
22
22
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57

Bare shaft pump

58

PACO KP, KPV

The double-suction design reduces axial forces by


directing flow into both sides of the impeller. The
double-volute design, available on most models,
reduces the radial load and minimizes noise and
vibration. Shaft sleeves are used to protect the shaft
from corrosion and wear, thus extending the overall life
of the shaft and the pump.

Fig. 1

KP pump with motor and base

Fig. 2

KP bare shaft pump with base, coupling, and


guard

Fig. 3

KP bare shaft pump

TM05 5003 2712

Ease of service and long-term reliability are two of the


selling features of the KP pumps. The split case design
enables removal and dismantling of the internal pump
parts (bearings, wear rings, impeller, and shaft seals)
without disturbing the motor or pipe work. The twobearing design means less vibration and higher
reliability. The separate bearing housings allow for
inspection of the seals, sleeves and bearings without
removing the top half of the casing.

TM04 7331 1910

The Paco KP horizontal split case pump and KPV


vertical split case pump are single stage, centrifugal
volute pumps with high energy efficiency and low lifecycle costs.

Features and benefits

1. Features and benefits

KP pumps cover this performance range:

Paco KP pumps are available in these different


options:
Pump with motor and base (see fig. 1).
Bare shaft pump, i.e. pump without motor, with base
(see fig. 2).
Bare shaft pump, i.e. pump without motor, without
base (see fig. 3).
Or any combination requested by the customer

Nameplate

TM05 7638 1313

The pumps are non-self-priming, centrifugal volute


pumps with radial suction and radial discharge ports
and horizontal shaft. Impellers are hydraulically
balanced.

TM05 5875 3912

Flow rate: 60 to 12000 gpm [10 to 2700 m3/h]


Head: 15 to 700 ft [5 to 215 m]
Motor (P2): 10 to 2000 hp

KPV pumps
Same great features of KP, but in a vertical
configuration for optimized space savings
Optional lower sleeve bearing design for easier
lower bearing maintenance.

PACO KP, KPV

Applications

2. Applications
The Paco KP pumps are used in these main fields of
application:
commercial systems
industrial systems
water distribution
irrigation.

Liquid transfer and pressure boosting in:


air conditioning, primary and secondary chilled
water systems
water condensing systems and cooling towers
boiler feed and condensate systems
district heating plants and heating systems
swimming pools
fountains.

TM05 5977 4012

Commercial systems

Fig. 4

KP pump used in commercial building applications

Fig. 5

KP pump in sprinkler irrigation

Industrial systems

Water distribution
Liquid transfer and pressure boosting in:
public waterworks
non-potable water systems.

Irrigation and aquaculture


Irrigation covers these applications:
field irrigation (flooding)
sprinkler irrigation
drip-feed irrigation
aqua farming.

GR 2910

Liquid transfer and pressure boosting in:


process cooling and chilled water systems
water condensing systems and cooling towers
boiler feed and condensate systems
industrial heating systems
wash down and cleaning systems
industrial processing systems (water, light
chemicals, oils, etc).

PACO KP, KPV

Product range

3. Product range
Pump configurations
Standard configuration

Optional configuration

Pump casing

Cast Iron

Ductile Iron

Impeller

Bronze

Cast Iron
Aluminium bronze
Stainless steel

Sleeve

Bronze

Stainless steel

Coupling

Spacer Coupling

Shaft seal

Mechanical seal:

Flange

ANSI 125

ANSI 250

Flushing line

None

Nylon
Copper
Stainless Steel

Wear rings

Bronze

Stainless Steel

Shaft

Steel

Stainless Steel

Motor efficiency class

NEMA Premium

Others on request

Pump direction of rotation

CW - clockwise

CCW - counter clockwise

Elastomeric
Grid

Soft packing

To a great extent the pumps can be adapted to the


requirements of the individual customer. For
customized solutions, contact your local Grundfos
company.

PACO KP, KPV

Performance range

4. Performance range
Paco KP pumps are available with 2-, 4- or 6-pole
motors. 8 and 10 pole are available on request.
The next three pages show the performance range
covered by these three motor types.
Knowing your required duty point, use the performance
ranges like this:

1.
2.
3.
4.

Go into the relevant performance range chart.


Find your duty point.
Note which pump type covers your duty point.
Go to section "Product range" and then to
"Performance curves and technical data" and find
more detailed information on your chosen pump.

90 100
70
60
23

TM05 5045 3812

80
25

100
30

120
40

150
50

200
60

70

80

300
90

500

400

100

H
[m]

H
[ft]

100

30

150

40

200

50

250

300

2095-1/2

80

400

500

600

3095-7/8

800

200

1000

4012-1/2

300

Q [m/h]

2000
1500

Q [US GPM]

4012-7/8

3550 rpm, 60 Hz

KP

KP 2-pole

TM05 5978 3812

10

20

30

40

50

80
70
60

100

200

H
[m]

15

20

25

40

50

60

80

100

150

200

250

400

500

600

800

H
[ft]

23

100

30

150

40

2095-1/2

2013-5/6

50 60 70 80

200 250 300

4012-1/2

100

400 500 600

3095-7/8

3014-7/8

200

800 1000

4012-7/8

4015-9/0
5015-9/0

300

6015-3/4

6020-3/4

8015-3/4

400 500 600

6000

1012-1/2

1015-3/4

8020-5/6

800 1000

3000 4000

8012-5/6

6012-3/4

1500 2000

5012-7/8

6019-7/8

1024-3/4

KP

15000

KP 4-pole

Performance range

2000 Q [m/h]

Q [US GPM]

10000

1415-1/2

1020-3/4

1780 rpm, 60 Hz

PACO KP, KPV

10

12

15

20

30

40

50

60

80

100

120

150

200

300

TM05 5047 3812

8
7
6

10

20

30

40

50

80
70
60

100

400

H
[ft]

100

400

500

600

200

800

6019-7/8

1000

1500

300

8015-3/4

400

500

2000

6020-3/4

1415-1/2

1020-3/4

5000 6000

1000

4000

600 700 800

2500 3000

1012-1/2

1015-3/4

8020-5/6

1024-3/4

2000

15000

Q [m/h]

Q [US GPM]

8000 10000

1220-5/6

1180 rpm, 60 Hz

KP

Performance range

H
[m]

4
PACO KP, KPV

KP 6-pole

PACO KP, KPV

Construction

5. Construction
Paco KP horizontal split case pumps are available in
several different construction types.

KP pump, construction X2
All four construction types are available with packing
as an option.

TM03 9952 4707

Sectional view

Fig. 6

Sectional view, construction X2, with mechanical shaft seals

PACO KP, KPV

Construction

KP pump, construction X4
Sectional view

66 20e 45

11

17

49 6a

109 114

53 113e

116b

113c

195

51

113d

11a

54
114a
79

124

116a

6b
24

TM05 7482 1013

105

Fig. 7

10

Sectional view, construction X4, with mechanical shaft seals

PACO KP, KPV

Construction

KP pump, construction X5 and X7

TM03 9954 4707

Sectional view

Fig. 8

Sectional view, construction X5/X7, with mechanical shaft seals

11

PACO KP, KPV

Construction

KP pump, construction XK and XV

TM03 9955 4707

Sectional view

Fig. 9

12

Sectional view, construction XK/XV, with mechanical shaft seals

PACO KP, KPV

Construction

KP pump, typical end view - Horizontal

TM04 1864 1108

(Non-drive end)

Fig. 10 Typical end view (non-drive end)

13

PACO KP, KPV

Construction

Std. components and material specification


Pos. no. Component

ASTM standard
ASTM A48 CL35

6a

Pump casing, upper

Cast Iron

6b

Pump casing, lower

Cast iron

11

Key, impeller

Steel

C1018, cold drawn steel

11a

Key, coupling

Steel

C1018, cold drawn steel

17

Pipe plug

Steel

20

Drain plug R 1/2

Steel

20a

Plug, drain outlet

Steel

20b

Plug, inlet

Steel

20c

Plug, outlet

Steel

ASTM A48 CL35

20d

Plug, shaft seal flushing

Steel

20e

Plug, suction chamber

Steel

24

Locking pin, wear ring

Steel

ANSI/ASME B18.8

26b

Roll pin

Steel

ANSI/ASME B18.8

26c

Screw

Steel

45

Wear ring

Bronze

ASTM B148, C95200

45b

Wear ring with groove for retaining ring

Bronze

ASTM B148, C95200

49

Impeller

Silicon bronze

ASTM B584, C87600

51

Shaft

Steel

AISI 1144 Stress proof

53

Ball bearing, drive end

Steel

54

Ball bearing, non-drive end

Steel

54c

Washer

Steel

54d

Retaining ring

Carbon Spring Steel

58

Seal cover

Grey Iron

58a

Screw

Steel

65

Retaining ring

Stainless steel, series 303

66

O-ring

NBR

Impeller/shaft sleeve nut, right-hand thread

Bronze

Impeller/shaft lock nut, right-hand thread

Stainless steel

67a

Impeller/shaft sleeve nut, left-hand thread

Bronze

Impeller/shaft lock nut, left-hand thread

Stainless steel

72a

Gasket

Vegetable fiber (HYD-401)

76

Nameplate

Aluminum

79

Slinger

Neoprene

105

Shaft seal

67b

14

Material

SAE 1060-1090

lll932, C89835
lll932, C89835

109

O-ring

NBR

109a

O-ring

NBR

110

O-ring

NBR

113

Bearing housing

Cast iron

ASTM A48, CL30

113c

Bearing cover, drive end

Cast iron

ASTM A48, CL30

113d

Bearing cover, non-drive end

Cast iron

ASTM A48, CL30

113e

Gasket

Vegetable fiber

113f

Lip seal, non-drive end bearing

NBR

113g

Lip seal, drive-end bearing

NBR

114

Screw

Steel

114a

Screw

Steel

114b

Screw

Steel

116

Shaft sleeve

Bronze

III932, C89835

116a

Shaft sleeve, drive end

Bronze

I836 C89833

116b

Shaft sleeve, non-drive end

Bronze

I836 C89833

116c

Shaft sleeve, inner

Bronze

I836 C89833

116d

Shaft sleeve, outer

Bronze

I836 C89833

116e

Set screw

Steel

124

Seal housing

Cast iron

195

Lubricating nipple

Zinc coated steel

ASTM A48 CL30

PACO KP, KPV

Mechanical construction

Construction

Bearings
KP pumps are fitted with two standard single-row
deep-groove ball bearings. The bearings are of the
open type permitting the bearings to be relubricated.
The bearings are lubricated by Grundfos prior to
delivery.

Pump casing
The class 35 grey iron volute pump casing has radial
suction port and radial discharge port.
The pumps are of the inline (symmetric) design.

TM04 0476 0708

Seal housings

Fig. 11 Schematic drawing of an inline KP pump

Flange Drillings are in accordance with ANSI #125 or


#250.

All KP pumps have two seal housings (pos. 124), one


at the drive end and one at the non-drive end of the
pump shaft.
A seal housing has several functions:
Supports the pump sealing system, whether it is a
mechanical shaft seal or packing
Supports the bearing housing thus transmitting both
radial and axial forces from bearing and shaft to the
upper and lower pump casing
Has a connection for the flushing pipe.
The function of the flushing pipe is to ensure a flow
of pumped liquid for cooling and lubricating the
mechanical shaft seal or the packing
Impeller

TM03 3891 1106

TM04 0475 0708

The KP impeller (pos. 49) is a closed double-suction


impeller. The impeller has inflow of liquid from both
sides and is locked in position by a threaded sleeve
arrangement.

Fig. 12 Upper and lower pump casing of KP pump

Shaft
The shaft (pos. 51) is of the key and keyway type with
one key for the impeller (pos. 11) and one key for the
coupling (pos. 11a).
The shaft is supported by bearings at both the drive
end and the non-drive end of the pump.

Fig. 14 Double-suction impeller

All impellers are dynamically balanced in accordance


with ANSI/ISO 1940 Class G6.3 standard. Due to their
design, the impellers are inherently hydraulically
balanced and thus compensate for axial thrust.
All impellers are trimmed to the duty point required by
the customer.

TM04 0477 0708

Wear rings

Fig. 13 KP pump shaft

Shaft sleeves are attached to the pump shaft to


prevent wear of the shaft and secure the position of the
impeller.

KP pumps have wear rings (pos. 45) between impeller


and pump casing. As the name indicates, the wear
rings protect the pump casing against wear. The wear
rings act as a seal between impeller and pump casing.
When the wear rings become worn, the efficiency of
the pump will be reduced and the wear rings should be
replaced.
Coupling
As standard, KP pumps are fitted with a flexible grid
coupling or elastomeric coupling, depending or motor
size. The grid coupling consists of two steel flanges
horizontally split coupling halves.

15

PACO KP, KPV

The packing rings consist of braided material which is


effective for long service life for packing rings while
protecting the shaft sleeve.

TM04 1849 1108

TM04 0478 0708

Construction

The coupling design assists in reducing vibrations and


cushions shock loads. The design also extends the life
of the coupling itself. The flexible grid is standard for
VFD driven pumps.

Fig. 15 Flexible grid coupling

The elastomeric coupling has a flexible rubber section


to absorb vibrations and minimizes negative affects of
misalignment.
Fig. 18 Sectional view of packing with internal flushing
liquid
Pos.

TM05 5784 3812

Mechanical shaft seal


The material of the standard version is Buna Carbon/
ceramic.

Includes graphite impregnated packing rings.

16

Gland

Packing ring

Lantern ring

Drilled hole for flushing liquid (pumped liquid)

Base

Painting
Prior to delivery to the customer, pump, motor and
base are top coated with a blue paint (RAL 5015);
coating thickness is 2 to 4 mils.The inside of the pump
is primered for corrosion resistance. Standard units are
not painted internally.
TM04 0472 0708

Packing

Pump and motor are mounted on a common base


frame designed according to Hydraulic Institute
standard, ANSI/HI 1.3-2000.

Fig. 16 elastomeric coupling

Fig. 17 Rubber bellows shaft seal

Description
Shaft sleeve

PACO KP, KPV

Construction

Test pressure
Pressure testing is made with water at ambient
temperature. The standard hydrostatic test pressure is
1.5 times the flange rating pressure.

KP Case working pressure limitations at 150 F: Flat-face flanges


Chart A
Class 125 lb flange drilling (psi)

Class 250 lb flange drilling (psi)

CWP

Hydro

CWP

Hydro

175
175

265
265

250
400

375
600

Cass material
Cast iron
Ductile iron
All sizes except as Chart B indicates

Chart B
Maximum case working pressure (class 125 Flange)
Pump model number

6019

6020

8020

Cast iron

1020

1024

1220

175 psi

Ductile iron

Maximum case working pressure (class 250 Flange)


Pump model number

6019

6020

8020

1020

1024

1220

Cast iron

250 psi

250 psi

234 psi

222 psi

250 psi

211 psi

Ductile iron

375 psi

375 psi

351 psi

333 psi

375 psi

317 psi

CWP: maximum Case Working Pressure based upon flange drilling. Maximum working pressure for a given application is determined by adding the
maximum available suction pressure to the shut-off head of a given impeller diameter.
Hydro: Is the hydrostatic test pressure applied to the pump. Minimum hydrostatic test pressure is 1.5 times maximum allowable case working pressure.

17

PACO KP, KPV

Operating conditions

6. Operating conditions
Ambient temperature and altitude

Carbon/Ceramic

The ambient temperature and the installation altitude


are important factors for the motor life, as they affect
the life of the bearings and the insulation system.
Ambient temperature must not exceed 104 F [+ 40
C]. If the ambient temperature exceeds 104 F [+ 40
C] or if the motor is installed more than 3280 ft [1000
m] above sea level, the motor must not be fully loaded
due to the low density and consequently low cooling
effect of the air. In such cases, it may be necessary to
use a motor with a higher output, or use a motor that is
designed for the specified ambient conditions.
P2
[%]
110
100
90
80
70
60
20 25 30 35 40 45 50 55 60 65 70 T [C]
70

80

90 100 110 120 130 140 150 160 T [F]


3280

7382

11483

15584

[ft]

TM00 2189 1598

50

Fig. 19 Relationship between motor output (P2) and


ambient temperature

Liquid temperatures and shaft


seals
The maximum liquid temperature marked on the pump
nameplate depends on the mechanical shaft seal used:
Temperature range for Buna - standard):
32 F to 212 F [0 C to +100 C].
Temperature range for Viton
54 F to 212 F [+15 C to +100 C].
Temperature range for EPDM
54 F to 275 F [+15 C to +135 C].

Shaft seal
The materials of the shaft seal types used in KP pumps
have certain characteristics. These characteristics may
be of importance when choosing the shaft seal for the
pump.

The seal has the following features:


Brittle material requiring careful handling.
Worn by liquids containing solid particles.
Limited corrosion resistance, 5 < pH < 9, depending
on ceramic type.
The carbon of the seal offers properties very similar
to the carbon/tungsten carbide seal. However,
compared to the carbon/tungsten carbide seal, the
pressure and temperature ranges are limited.
Carbon/silicon carbide
Seals with one carbon seal face have the following
features:
Brittle material requiring careful handling
Worn by liquids containing solid particles
Good corrosion resistance
The self-lubricating properties of carbon make the
seal suitable for use even with poor lubricating
conditions (high temperatures) without generating
noise. However, such conditions will cause wear of
the carbon seal face leading to reduced seal life.
Buna
NBR (nitrile) rubber covers a wide range of liquids at
temperatures below 212 F [+100 C].
Good mechanical properties
Standard material
Viton
FKM rubber covers a very wide range of liquids and
temperatures.
Poor mechanical properties at low temperatures
Resistant to water up to 275 F [+135 C]
Resistant to mineral oils and vegetable oils
Not resistant to alkaline liquids at high
temperatures.
EPDM
EPDM Rubber covers a wider range of liquids up to a
max temperature of 275 F [135 C].
Good mechanical properties.

Pressure
Maximum inlet pressure
Inlet pressure + pump pressure must always be lower
than maximum pressure of the pump.
Minimum inlet pressure
The minimum inlet pressure must correspond to the
NPSH curve for the pump.

18

PACO KP, KPV

Operating conditions

Flow
Minimum flow rate
The pump must not run against a closed discharge
valve, as this will cause an increase in temperature/
formation of steam in the pump. This may cause shaft
damage, impeller erosion, short life of bearings, stuffing
boxes with packing rings or mechanical seals due to
stress or vibration.
The minimum, continuous flow rate must be at least
25% of the flow rate at best-efficiency point (BEP).

KP Impeller Max Sphere Size


Split Case Model

Max Sphere Size [inches]

2095-1/2

0.19

2013-5/6

0.16

3095-7/8

0.31

3014-7/8

0.31

4012-1/2

0.38

4012-7/8

0.75

4015-9/0

0.25

5012-7/8

0.63

5015-9/0

0.75

6012-3/4

1.00

6015-3/4

0.81

6019-7/8

0.75

6020-3/4

0.75

8012-5/6

0.88

8015-3/4

1.00

8020-5/6

1.03

1012-1/2

1.00

1015-3/4

1.25

1020-3/4

1.20

1024-3/4

1.17

1220-5/6

1.87

1415-1/2

1.25

19

PACO KP, KPV

KP model number and


construction code
Example

29

Materials of construction

60123

140001

1852

Product code
Model code
Materials of construction
Motor code
Production code

29

29: Split case


Model code

60

12

Pump discharge
20 = 2"
30 = 3"
40 = 4"
50 = 5"
60 = 6"
80 = 8"
10 = 10"
12 = 12"
14 = 14"
Nominal maximum impeller diameter
95 = 9.5"
12 = 12"
13 = 13"
14 = 14"
15 = 15"
19 = 19"
20 = 20"
24 = 24"
Impeller design
Clockwise rotation:
1, 3, 5, 7, 9
Counter clockwise rotation:
0, 2, 4, 6, 8
Materials of construction
Packing or seal
3 = Standard Packing
1 = Type 21, Single Seal, Ceramic Seat, Buna
2 = Type 21, Single Seal, Tung Crbd Seat, Viton
6 = Type 21, Single Seal, Ni-Resist Seat, Viton
7 = Type 21, Single Seal, Ni-Resist Seat, Buna
8 = Type 1B, Single Seal, Ni-Resist Seat, Buna
9 = Type 21, Single Seal, Ni Resist Seat, Viton
A = Type 1, Single Seal, Ceramic Seat, Buna
B = Type 1, Single Seal, Ni-Resist Seat, Viton
C = Type 1, Single Seal, Tung Cbrd Seat, Viton
D = Type 1, Singel Seal, Ni Resist Seat, Buna
E = Type 1, Single Seal, Ceramic Seat, Buna
F = Type 1, Single Seal, Si Cbrd Seat, EPDM
ID of packing or seal
2 = 1"
3 = 1-1/4"
E = 1-1/2"
4 = 1-3/4"
5 = 2-1/4"
6 = 2-3/4"
7 = 3"
K = 3-1/2"
V = 4"
General configuration (horizontal)
Code no
Item
00
Std.
01
Dbl- wear rings
02
Oil lube brgs
03
(01) + (02)
04
(01) + (05)
05
Recirc lines
20
Dbl Ext Shaft
21
Dbl Wear Rings
22
Recirc Lines

20

00

0 1

00

0 1

24
(21) + (22)
30
Dbl Ext Shaft
31
Dbl Wear Rings
General configuration (horizontal)
Code no
Item
32
Recirc Lines
34
(31) + (32)
70
250 lb. Flange
71
Dbl Wear Rings
72
(71) + (73)
73
Recirc Lines
90
250 lb. Flange
91
Dbl Wear Rings
General configuration (Vertical)
Code no
Item
50
Std
51
Dbl. Wear Rings
52
Sleeve Bearing
80
250 lb. flamge
81
Dbl. Wear Rings
82
Sleeve Bearing
92
250 lb. flamge
93
Dbl. Wear Rings
Shaft/Sleeve Metallurgy
0 = Steel/Bronze
1 = Steel/S.S.
3 = S.S.l/Bronze*
6 = S.S./S.S. or S.S./no sleeves
7 = SS/Hard. SS
A = 316 SS/Ni Al Bz
X = Special
Pump Metallurgy
1 = Brz. Fitted
2 = Std. All Bronze
5 = All Iron
8 = Ductile Iron/Brz. Fitted
X = Special
Motor code

Enclosure
1 = ODP
2 = TECF
3 = explosion proof
Voltage
1 phase
HP
115/230 V
1/3
21
1/2
29
3/4
35
1
41
1-1/2
47
2
53
3
59
5
65
7-1/2
71
10
76
15
-20
-25
-30
-40
-50
60
75
100
125
150
200
250
300
RPM
1 = 3500
2 = 1750
3 = 1150

----------

200 V
23
31
37
43
49

3 phase
230/460 V
24
32
38
44
50

55
61
67
73
77

56
62
68
74
78

81
84
01
02
03
04
05
06
07
------

82
85
87
88
89
90
91
92
93
94
95
96
97
98

78

PACO KP, KPV

Curve charts and technical data

7. Curve charts and technical data


How to read the curve charts
Size of impeller

H
[m]

H
[ft]

/9.5

420
120

Total pump
head
H = Htotal

KP 2095-1/2
60 Hz, n = 3550 rpm

400
380

110

/8.75

360

Pump type and


speed

340
100
90

320

/8.125

300

QH curve for the


individual pump.
The bold curve indicates
the recommended
performance range.

280
80

/7.5

260
240

70
60

220

/6.75

200
180

40

160
140

NPSH
[ft] [m]

120
30
20
10

100

100

80

80

60

60

40

40
NPSH

20
0

P2
[kW]
100

50

100

150

200

250

300

350

400

450

500

550

Eff
[%]

140

70

120

60
/6.75

/7.5

/8.125

/8.75

/9.5

100
80

The eta curves


show the efficiency
of the pumps shown

40

60

30

/8.75
/8.125

40
20

50

/9.5
40

10

The NPSH curve


is an average
curve for all
variants shown.

Q [US GPM]

P2
[hp]

80

60

20

20

0
0

30

20

/7.5
/6.75

20

10

0
0

50

100

20

150

200

250

40

60

300

350

80

400

The power curves


indicate pump input
power [P2] for the
pumps shown

450

100

500

550

120

Q [US GPM]
140

Q [m/h]

TM05 5009 3212

50

Reference the Express Suite selection tool for


selections in additional speeds.

21

PACO KP, KPV

Curve charts and technical data

Curve conditions

Performance tests

The guidelines below apply to the curves shown in the


performance charts.
Tolerances according to: Hydraulic Institute.
The curves show pump performance with different
impeller diameters at the nominal speed.
The bold part of the curves show the
recommended operating range.
Do not operate the pump along the thin parts of the
curves. If your duty point lies here, you should
select a smaller or larger pump type.
Do not use the pumps at minimum flows below 0.1 x
Qmax stated on the pump name plate because of the
risk of overheating of the pump.
The curves apply to the pumping of airless water at
a temperature of 77 F [+20 C] and a kinematic
viscosity of 1 cSt [1 mm2/s].
ETA: The lines show values of the hydraulic
efficiency of the pump for the different impeller
diameters.
NPSH: The curves show average values measured
under the same conditions as the performance
curves.
When sizing the pump, add a safety margin of at
least 1.6 ft [0.5 m].
In case of other densities than 62.3 lb/ft3 [1000 kg/
m3] the discharge pressure is proportional to the
density.
When pumping liquids with a specific gravity higher
than 1.0, motors with correspondingly higher
outputs must be used.

Requested tests are performed according to Hydraulic


Institute. Performance tests are only completed when
ordered with the pump.

Calculation of total head


The total pump head consists of the height difference
between the measuring points + the differential head +
the dynamic head.
H total

22

H geo

+ Hstat + Hdyn

Hgeo :

Height difference between measuring points.

Hstat :

Differential head between suction and the discharge side of


the pump.

Hdyn :

Calculated values based on the velocity of the pumped


liquid on the suction and the discharge side of the pump.

Witness test
When the pumps are being tested it is possible for the
customer to witness the testing procedure according to
Hydraulic Institute.
If the customer wants to witness the pump test this
request must be submitted with the order.

PACO KP, KPV

H
[m]

H
[ft]

/9.5

420
120

Curve charts and technical data

KP 2095-1/2 [2-pole]

KP 2095-1/2
60 Hz, n = 3550 rpm

400
380

110

/8.75

360
340

100
90

320

/8.125

300
280

80

/7.5

260
240

70
60

220

/6.75

200
180

50
40

160
140

NPSH
[ft] [m]

120
30
20
10

100

100

80

80

60

60

40

40
NPSH

20
0

P2
[kW]
100

50

100

150

200

250

300

350

400

450

500

550

10
0

Q [US GPM]

P2
[hp]

Eff
[%]

140

70

120

60

80

/6.75

/7.5

/8.125

/8.75

/9.5

100
60

20

20

0
0

30

50

80

40
/9.5

60
/8.125

40
20

30

/8.75

20

/7.5
/6.75

20

10

0
0

50

100

20

150

200

40

250

60

300

350

80

400

450

100

500

550

120

Q [US GPM]
140

Q [m/h]

TM05 5009 3212

40

23

PACO KP, KPV

Curve charts and technical data

KP 3095-7/8 [2-pole]

H
[m]

H
[ft]
420

120

KP 3095-7/8

/9.5

60 Hz, n = 3550 rpm

400
380

110

360

/8.75

340
100

90

320
300

/8

280
80

260
/7.25

240
70
220
60

200

/6.5

180
50

160
140

40

NPSH
[ft] [m]

120
30

20

10

100

100

80

80

60

60

40

40
NPSH

20
0

P2
[kW]

100

100

200

300

400

500

20

10

20

0
0

30

600

700

800

900

1000Q

[US GPM]

P2
[hp]

Eff
[%]

160

80

140

70
/8.75

120
80
100

/8

/7.25

/6.5

/9.5
/9.5

60
50

/8.75
60

80

40
/8

60

30
/7.25

40
20
0

20

10

0
0

24

20

/6.5

100

200

50

300

400

100

500

600

700

150

800

900

200

1000Q

[US GPM]
Q [m/h]

TM05 5010 3212

40

PACO KP, KPV

H
[m]

H
[ft]
440

130
120

Curve charts and technical data

KP 4012-1/2 [2-pole]

KP 4012-1/2

/10.3

420

60 Hz, n = 3550 rpm

400
380

110

360

/9.4

340
100
90

320
300

/8.4

280
80

260
240

70
60

/7.5

220
200
180

50
40
30
20
10

/6.5

160

NPSH
[ft] [m]

140
120

120

100

100

80

80

60

60

40

40

NPSH

20
0

0
100

200

300

400

500

600

700

800

900 1000 1100 1200 1300 1400

80

280
240

50
/10.3

160
120
/8.4

80
/6.5

40
30

/9.4

40

70
60

/7.5
/6.5

200

/10.3

/9.4

/8.4

160

40

Eff
[%]

320

80

10

Q [US GPM]

P2
P2
[kW] [hp]

120

20

20

200

30

20

/7.5
10

0
0

100

200

50

300

400

100

500

600

700

150

800

900 1000 1100 1200 1300 1400

200

250

300

Q [US GPM]
Q [m/h]

25

PACO KP, KPV

Curve charts and technical data

KP 4012-7/8 [2-pole]

H
[m]
120

H
[ft]
400

KP 4012-7/8

/9.4

60 Hz, n = 3550 rpm

380
110

360
/8.8

340
100

90

320
300

/8.2

280
80

260

/7.6

240
70
220
60

/7.0

200
180

50

40

30

20

10

160

NPSH
[ft] [m]

140
120

120

100

100

80

80

60

60

40

40

NPSH

20
0

0
200

400

600

800

1000

1200

1400

1600

1800

2000Q

[US GPM]

P2
P2
[kW] [hp]

Eff
[%]

400

80

350

70
/9.4

300
250

100

200

40

/7.6
/7.0

150

/9.4
/8.2

/7.0

50

/8.8

30
20

/7.6

10

0
0

26

50

/8.2

100
50

60

/8.8

200
150

20

10

20

250

30

200

400

100

600

800

200

1000

1200

1400

300

1600

1800

400

2000Q

[US GPM]
Q [m/h]

PACO KP, KPV

H
[m]

Curve charts and technical data

KP 2095-1/2 [4-pole]

H
[ft]

KP 2095-1/2

35
110

60 Hz, n = 1780 rpm


/9.5

30

100

90
25

/8.75

80
/8.125
70

20

/7.5
60

15

/6.75

50

40

NPSH
[ft] [m]

10
30

30
8

20

20

10

10

5
4
2

NPSH
0

0
0

P2
[kW]
10

20

40

60

80

100

120

140

160

180

200

220

240

260

P2
[hp]

Eff
[%]

14

70

12

60

/7.5

/6.75

/8.125

/8.75

10
6

/9.5
/9.5

8
/8.75

50
40
30

/8.125
4

20

/7.5

/6.75

2
0

Q [US GPM]

10

0
0

20

40

10

60

80

100

20

120

140

30

160

180

40

200

220

50

240

260

60

Q [US GPM]
Q [m/h]

TM05 5013 3912

27

PACO KP, KPV

Curve charts and technical data

KP 2013-5/6 [4-pole]

H
[m]

H
[ft]

KP 2013-5/6
60

60 Hz, n = 1780 rpm

200
/13
180

50

/12

160

140

/11

40
120

30

/10

100
/9
80

NPSH
[ft] [m]

20
60

30
8

40

20

20

10

10
4

NPSH

0
0

P2
[kW]

40

80

120

160

200

240

280

320

360

Q [US GPM]

P2
[hp]

Eff
[%]

60

60

40
50

/13

50

/12
30

40

/10

/11

40

/9
30

30
/13

20

/12

10
10
0

/9

/10

10

0
0

28

20

/11

40

80

20

120

160

200

40

240

280

60

320

360

80

Q [US GPM]
Q [m/h]

TM05 5014 3912

20

PACO KP, KPV

H
[m]

Curve charts and technical data

KP 3095-7/8 [4-pole]

H
[ft]

KP 3095-7/8

35
110

60 Hz, n = 1780 rpm


/9.5

30

100

90
25

/8.75

80
/8
70

20

15

60

/7.25

50

/6.5

40

NPSH
[ft] [m]

10
30

15
4

20

10

5
2

NPSH
10

5
1

0
0

P2
[kW]

20

50

100

150

200

250

300

350

400

450

500 Q

P2
[hp]

Eff
[%]

32

80

28

70
/9.5

24
16

/6.5

/7.25

/8.75

/8

20
12
8

60
50

16

/9.5
/8.75

12

40
30

/8

8
4

[US GPM]

20

/7.25
/6.5

10

0
0

50

100

20

150

200

40

250

60

300

350

80

400

450

100

500 Q

[US GPM]

120

Q [m/h]

TM05 5015 3912

29

PACO KP, KPV

Curve charts and technical data

KP 3014-7/8 [4-pole]
H
[m]

H
[ft]

KP 3014-7/8

70
/14.0

220

60

60 Hz, n = 1780 rpm

200
/13.0
180

50

/12.0

160

140

/11.0

40
120
/10.0
30

100

80

NPSH
[ft] [m]

20
60

60

40

40

15
10

10
20

20
NPSH

0
0

200

300

400

500

600

700

800

P2
[hp]

Eff
[%]

60
40

/12.0

/11.0

/10.0

/14.0

/13.0

/14.0

50
30

20

/13.0

40

60

40

/11.0

30

/10.0

10
10

20

10
0

30

70

50

/12.0

30
20

Q [US GPM]

100

200

50

300

400

500

100

600

700

150

800

Q [US GPM]
200

Q [m/h]

TM05 5016 3912

P2
[kW]

100

TM05 5016 3212

PACO KP, KPV

H
[m]

H
[ft]

40

130

Curve charts and technical data

KP 4012-1/2 [4-pole]

KP 4012-1/2
60 Hz, n = 1780 rpm

/11.0
120
35
110

30

100

/9.9

90
25

80
/8.7
70

20
60
/7.6
15

50

NPSH
[ft] [m]

40
10

40

/6.5

30

30

12
10
8

20

20

5
10

25

100

200

300

400

500

600

700

40

80

35

70
/8.7
/7.6

25

60

/11.0

/6.5

20

50
40

/9.9

15

30
/8.7

10
5

/11.0

/9.9

Q [US GPM]
Eff
[%]

30

10

900

P2
[hp]

20
15

800

20

/7.6
5

10

/6.5

0
0

100

200

50

300

400

500

100

600

700

150

800

900

200

Q [US GPM]
Q [m/h]

TM05 5017 3912

P2
[kW]

0
0

TM05 5017 3212

10

NPSH

31

PACO KP, KPV

Curve charts and technical data

KP 4012-7/8 [4-pole]
H
[m]

H
[ft]

KP 4012-7/8

/12.0

160

60 Hz, n = 1780 rpm


45

150
140

40

/10.8

130
120

35
110
30

/9.5

100
90

25

80
/8.3
70

20
60
/7.0

40

40

30

30

20

20

10
0

0
0

P2
[kW]

10

NPSH

100

200

300

400

500

600

700

800

900

1000

1100

P2
[hp]
/12.0

70
/9.5

80

50
/12.0

40

40
/10.8

30

30

/9.5

20

/8.3

10

10

/7.0

0
0

32

60

/7.0

20

/8.3
50

10

70

/10.8

60

20

Eff
[%]

40
30

10

Q [US GPM]

80
50

12

100

200

50

300

400

100

500

600

700

150

800

900

200

1000

1100

Q [US GPM]

250

Q [m/h]

TM05 5018 3912

10

NPSH
[ft] [m]

50

TM05 5018 3212

15

PACO KP, KPV

H
[m]
90

H
[ft]

Curve charts and technical data

KP 4015-9/0 [4-pole]

KP 4015-9/0

300

60 Hz, n = 1780 rpm

/15.25
280

80

260
/14.0

240
70
220
60

200

/12.5

180
50

160
/11.0
140

40
120
30

/9.5

100

NPSH
[ft] [m]

80
20

60

60

40

40

20

20

15
10

10
NPSH
0

0
0

100

400

600

800

1000

1200

1400

P2
[hp]

Eff
[%]

160

80

140

/9.5

/11.0

/12.5

/14.0

120

/15.25

70
60

/15.25

80
100
60
40

50
/14.0

80
60

40
30

/12.5

40
20

Q [US GPM]

20

/11.0
/9.5

20

10

0
0

200

400

100

600

800

1000

200

1200

1400

300

Q [US GPM]
Q [m/h]

TM05 5019 3912

P2
[kW]

200

TM05 5019 3212

33

PACO KP, KPV

Curve charts and technical data

KP 5012-7/8 [4-pole]
H
[m]

H
[ft]

KP 5012-7/8
60 Hz, n = 1780 rpm

180

50

/12.0
160

140
/10.75

40
120

30

/9.5

100

NPSH
[ft] [m]
80

40

/8.25

12

20
60

30

/7.0

40

20

20

10

10
4
NPSH
0

0
0

200

400

600

800

1000

1200

1400

1600

1800

P2
[kW]

Q [US GPM]

90

80

80
/9.5

/12.0

/10.75

/9.5

60

70
60

/7.0

50

/12.0

40

50
40

/10.75

30

30
/9.5

20

/9.5

10

10

/7.0

0
0

200

400

100

600

800

1000

200

1200

1400

300

1600

1800

400

Q [US GPM]
Q [m/h]

TM05 5020 3912

20

34

Eff
[%]

90

70

TM05 5020 3212

PACO KP, KPV

H
[m]

H
[ft]

KP 5015-9/0

280
80

Curve charts and technical data

KP 5015-9/0 [4-pole]

60 Hz, n = 1780 rpm

/15.0
260
240

70
220
/13.5
60

200
180

50

/12.0

160
140

40

/10.5

120
30

100

/9.0

NPSH
[ft] [m]

80
20

60

60

40

40

15
10

10
20

0
0

P2
[kW]

20

NPSH

200

400

600

800

1000

1200

1400

1600

1800

2000

Q [US GPM]

P2
[hp]

Eff
[%]

320
200

80
/12.0

280

/13.5

/15.0

/10.5
/9.0

240

70
60

160
200

120

30
/13.5

80
40

20

/12.0

40
/9.0

40

10

/10.5

0
0

200

400

100

600

800

200

1000

1200

1400

300

1600

1800

400

2000

Q [US GPM]
500

Q [m/h]

TM05 5021 3912

80

/15.0

160

TM05 5021 3212

120

50

35

PACO KP, KPV

Curve charts and technical data

KP 6012-3/4 [4-pole]
H
[m]

H
[ft]

KP 6012-3/4

170
50

45

/12.0

60 Hz, n = 1780 rpm

160
150
140

40

/10.75
130
120

35
110
30

/9.5

100
90

25

/8.25

80
70

20
60

10

NPSH
[ft] [m]

50
40

40

30

30

20

20

10
0

NPSH

0
0

P2
[kW]
200

10

400

800

1200

1600

2000

2400

2800

Eff
[%]

280

90

240

160

/8.25

120

/9.5

2
0

60
50

/7.0

/12.0
40

/10.75
/9.5

40

30

/8.25

20
0

36

70

/10.75

/7.0
0

80

80
40

/12.0
200

80

10

Q [US GPM]

P2
[hp]

160

120

12

400

800

200

1200

1600

2000

400

2400

2800

600

Q [US GPM]
Q [m/h]

TM05 5023 3212

15

/7.0

PACO KP, KPV

H
[m]

H
[ft]

80

260

Curve charts and technical data

KP 6015-3/4 [4-pole]

KP 6015-3/4
60 Hz, n = 1780 rpm

/15.0

240
70
220
/13.5
60

200
180

50

/12.0

160
140

40

/10.5
120

30

100

/9.0

80
20

NPSH
[ft] [m]

60

60

40

40

15
10

10
20
0

0
0

P2
[kW]

200

400

800

1200

1600

2000

2400

2800

3200

3600

Eff
[%]

320

90

280

80
/12.0

240

/13.5

/15.0

/10.5

/9.0

/15.0

200

80

160

70
60
50

/13.5

120

40
/12.0

80
40

Q [US GPM]

P2
[hp]

160
120

30

/10.5

40

20

/9.0

10
0

400

800

200

1200

1600

400

2000

2400

2800

600

3200

3600

800

Q [US GPM]
Q [m/h]

TM05 5024 3912

20

NPSH

37

PACO KP, KPV

Curve charts and technical data

KP 6019-7/8 [4-pole]

H
[m]

H
[ft]

KP 6019-7/8

140
440

60 Hz, n = 1780 rpm


/19.0

120

400
/18.0
360
/17.0

100

320
/16.0
280

80

/15.0
240

60

200

NPSH
[ft] [m]

160

80

120

60

40

20
15
80

40

20

10
40

20

NPSH
0

0
0

400

800

1200

1600

2000

2400

2800

Q [US GPM]

P2
P2
[kW] [hp]

Eff
[%]

400
250

80

350

/15.0 /16.0 /17.0 /18.0

300
250

100

200

50
40

/17.0
/16.0

150

30

/15.0

20

50

10

0
0

38

60

/18.0

100
50

70

/19.0

200
150

/19.0

400

800

200

1200

1600

2000

400

2400

2800

600

Q [US GPM]
Q [m/h]

PACO KP, KPV

H
[m]

H
[ft]

KP 6020-3/4

/20.0

480

Curve charts and technical data

KP 6020-3/4 [4-pole]

60 Hz, n = 1780 rpm

140
440
/18.5
120

400

360
100

/17.0

320
/15.5
280

80
240

60

/14.0

200

160
40

NPSH
[ft] [m]

120

60

80

40

15
20

10

NPSH
40

0
0

500

800

1200

1600

2000

2400

2800

3200

3600

P2
[hp]

Eff
[%]

800

80

700
600

/14.0

400

/15.5

/17.0

/18.5

200

300

70
60

/18.5

400

50
40
30

/17.0
/15.5

200
100

/20.0

/20.0

500
300

Q [US GPM]

20

/14.0

100

10

0
0

400

800

200

1200

1600

400

2000

2400

2800

600

3200

3600

800

Q [US GPM]
Q [m/h]

TM05 5026 3912

P2
[kW]

400

TM05 5026 3212

20

39

PACO KP, KPV

Curve charts and technical data

KP 8012-5/6 [4-pole]
H
[m]

H
[ft]

KP 8012-5/6

170
50

45

/12.0

60 Hz, n = 1780 rpm

160
150
140

40

/10.8
130
120

35
110
/9.5
30

100
90

25

/8.25

80
70

20
60
15

10

/7.0

NPSH
[ft] [m]

50
40

40

30

30

20

20
NPSH

10
0

10

0
0

P2
[kW]

P2
[hp]

120

160

500

1000

1500

2000

2500

3000

3500

4000

Q [US GPM]

12
10
8
6
4
2
0

Eff
[%]
90
80

/12.0
/10.8

140
/8.25

120

60
40

50
/10.8

80

40

60

30

/9.5

20

/8.25
/7.0

20

10

0
0

40

60

100

40
20

/12.0

/7.0

500

1000

200

1500

2000

400

2500

600

3000

3500

800

4000

Q [US GPM]
1000 Q

[m/h]

TM05 5027 3912

80

70

/9.5

TM05 5027 3212

100

PACO KP, KPV

H
[m]

H
[ft]

80

260

Curve charts and technical data

KP 8015-3/4 [4-pole]

KP 8015-3/4
/15.0

60 Hz, n = 1780 rpm

240
70
220
/13.5
60

200
180

50

/12.0

160
140

40

/10.5
120

30

100

/9.0

80
20

NPSH
[ft] [m]

60

60

40

40

15
10

10
20
0

0
0

1000

1500

2000

2500

3000

3500

4000

4500

5000

Q [US GPM]

P2
[hp]
450

300
250

150
100

400

80

350

/13.5

/12.0

/10.5

/15.0
/15.0

/9.0

250
200
150

60

40
30

/12.0

20

/10.5
/9.0

50

70

50
/13.5

100
50

Eff
[%]
90

300
200

10

0
0

500

1000

200

1500

2000

400

2500

600

3000

3500

800

4000

4500

1000

5000

1200

Q [US GPM]
Q [m/h]

TM05 5028 3912

P2
[kW]

500

TM05 5028 3212

20

NPSH

41

PACO KP, KPV

Curve charts and technical data

KP 8020-5/6 [4-pole]
H
[m]

H
[ft]
440

130
120

60 Hz, n = 1780 rpm

400
380

110

KP 8020-5/6

/19.25

420

/17.94

360
340

100
90

320

/16.62

300
280

80
70
60

/15.31

260
240
/14.0

220
200
180

50
40

160
140
120

30
20
10

NPSH
[ft] [m]

100
80

80

60

60

40

40
NPSH

20
0

0
0

P2
[kW]

500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000

Q [US GPM]

P2
[hp]
1800

1200
1000

600

15
10

20

Eff
[%]
90

1600
1400
/14.0

1200
800

20

/16.62
/15.31

/17.94

/19.25

80
70
60

1000

50

800

40
/19.25

600

/14.0

200

20
10

0
0

42

/16.62
/15.31

500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000

200

400

600

800

1000

1200

1400

1600

Q [US GPM]
Q [m/h]

TM05 5029 3912

400
200

30

/17.94

TM05 5029 3212

400

PACO KP, KPV

H
[m]

H
[ft]

KP 1012-1/2

170
50

60 Hz, n = 1780 rpm

/12.0

160
45

Curve charts and technical data

KP 1012-1/2 [4-pole]

150
140
/11.07

40

130
120

35
/10.15

110
30

100
/9.23

90
25

80
/8.3
70

20
60
15

50

NPSH
[ft] [m]

40
10

30

60

20

40

15
5

10
NPSH

10
0

0
0

P2
[kW]

500

1000 1500

2000 2500

3000

3500 4000

4500 5000

5500

6000

20

Q [US GPM]

P2
[hp]

Eff
[%]

360

90

240

320

80

200

280

/10.15
/9.23

240

/12.0

/11.07

70
60

160
200
120

50

/8.3
/12.0

160

40

/11.07
120

30
/10.15

80
40
0

20

/9.23
/8.3

40

10

0
0

500

1000 1500

200

2000 2500

400

600

3000

3500 4000

800

4500 5000

1000

5500

1200

6000

1400

Q [US GPM]
Q [m/h]

TM05 5030 3912

80

43

PACO KP, KPV

Curve charts and technical data

KP 1015-3/4 [4-pole]
H
[m]

H
[ft]

KP 1015-3/4

280
80

60 Hz, n = 1780 rpm

/15.37
260
240

70

/14.18

220

60

200
/13.0

180
50

160

/12.0

140

/11.0

40
120
30

100

NPSH
[ft] [m]

80
20

60

60

40

40

15
10

10
20
0

0
0

P2
[hp]

Q [US GPM]

900
600
500

300
200

800

80
/14.18

700
/12.0

70
60

/11.0

500

50
/15.37

400
/14.18

300
/13.0
/11.0

100

40
30
20

/12.0
10

0
0

44

/15.37

/13.0

200
100

Eff
[%]
90

600
400

500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000

200

400

600

800

1000

1200

1400

1600

Q [US GPM]
Q [m/h]

TM05 5031 3912

P2
[kW]

500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000

TM05 5031 3212

20

NPSH

PACO KP, KPV

H
[m]

H
[ft]

Curve charts and technical data

KP 1020-3/4 [4-pole]

KP 1020-3/4

480

60 Hz, n = 1780 rpm

140
/19.6

440

120

400
/18.25
360

100

/16.75

320

280

NPSH
[ft] [m]

/15.4

80
240

120
/14.0

60

40

35

200

100

30

160

80

25

120

60

80

40

20
15

20

10
NPSH

40

0
0

2000

3000

4000

5000

6000

7000

8000

9000

10000

P2
[hp]

Eff
[%]

1600
1000

90

1400
/15.4

1200

/16.75

/18.25

/19.6

800
600

60
50

/18.25

40

/16.75
/15.4

400
200

80
70

1000

400

/19.6

/14.0

800
600

Q [US GPM]

30

/14.0

200

20

10
0

1000

2000

500

3000

4000

5000

1000

6000

7000

1500

8000

9000

2000

10000

Q [US GPM]
2500

Q [m/h]

TM05 5032 3912

P2
[kW]

1000

TM05 5032 3212

20

45

PACO KP, KPV

Curve charts and technical data

KP 1024-3/4 [4-pole]
H
[m]

H
[ft]

KP 1024-3/4

/24.8

750

60 Hz, n = 1780 rpm

220
700
200

180

650

/23.0

600
550
/21.0

160
500
140

450
/19.0

120

400
350

/17.0

100
300

200

80

150

60

100

40

40

20

15
10
NPSH

50

20

0
0

P2
[kW]

1000

2000

3000

4000

5000

6000

7000

8000

P2
[hp]

Q [US GPM]

90

3200

80

2000

2800
/17.0

1200
800

/23.0

/21.0

/24.8

/24.8

1600

50

30

/21.0

20

/19.0
/17.0

400

70

40

/23.0

1200

10

0
0

1000

2000

500

3000

4000

5000

1000

6000

7000

1500

8000

60

2000

800
400

/19.0

Eff
[%]

3600

2400

46

9000 10000 11000

2400

1600

20

9000 10000 11000

2000

2500

Q [US GPM]
Q [m/h]

TM05 5033 3912

60

NPSH
[ft] [m]

250

TM05 5033 3212

80

PACO KP, KPV

H
[m]

H
[ft]

KP 1415-1/2

280

60 Hz, n = 1780 rpm

/15.6
80

Curve charts and technical data

KP 1415-1/2 [4-pole]

260
/14.75

240
70
220

/13.75
60

200
/13.0
180

50

/12.0

160
140

40
120
30

20

NPSH
[ft] [m]

100
80

80

60

60

40

40

20
15

NPSH

10

10

20
0

0
0

2000 3000

4000 5000

6000

7000 8000

9000 10000 11000 12000

P2
[hp]

Q [US GPM]

Eff
[%]

900

90

600

800

80

500

700
/12.0

600
400
300
200

70

/14.75 /15.6
/13.0 /13.75

60

500

50

400

/15.6
/14.75
/13.75

300
200

100

/12.0

40
30

/13.0

20

100

10

0
0

1000

2000 3000

500

4000 5000

1000

6000

7000 8000

1500

9000 10000 11000 12000

2000

2500

Q [US GPM]
3000 Q

[m/h]

TM05 5034 3912

P2
[kW]

1000

TM05 5034 3212

20

47

PACO KP, KPV

Curve charts and technical data

KP 6019-7/8 [6-pole]
H
[m]

H
[ft]
190

55

45

60 Hz, n = 1180 rpm

180
170

50

KP 6019-7/8

/19.0

/18.0

160
150

/17.0

140
40

/16.0

130
120

35

/15.0

110
30

100
90

25

20

80
70
60

15

10

NPSH
[ft] [m]

50
40

40

30

30

20

20

10
0

0
0

P2
[kW]

100

10

NPSH
200

400

600

800

1000

1200

1400

1600

1800

10
8
6
4
2
0

Q [US GPM]

P2
[hp]

Eff
[%]

160

80

140

12

/18.0
/15.0 /16.0 /17.0

/19.0

70

120

60

100

50

80

/18.0

60

20

/15.0

20

10

0
0

48

30

/17.0
/16.0

40
20

40

200

400

100

600

800

1000

200

1200

1400

300

1600

1800

400

Q [US GPM]
Q [m/h]

TM05 5035 3912

40

/19.0

80

TM05 5035 3212

60

PACO KP, KPV

H
m]

H
[ft]

KP 6020-3/4

70
220

60 Hz, n = 1180 rpm

/20.0
60

200
/18.5

180
50

Curve charts and technical data

KP 6020-3/4 [6-pole]

160

/17.0

140
40

/15.5
120

30

/14.0

100

80

NPSH
[ft] [m]

20
60

30
8

40

20

10

NPSH

6
4

20

10
2

0
0

P2
kW]

00

200

400

600

800

1000

1200

1400 1600

1800 2000

2200

2400

P2
[hp]

Eff
[%]

320

80

280
240

/14.0

60

/15.5

/17.0

/18.5

/20.0

80

50

160

/20.0

120
/17.0

20

/15.5
/14.0

40

40
30

/18.5

80
40

70
60

200
20

Q [US GPM]

10

0
0

200

400

100

600

800

1000

200

1200

1400 1600

300

1800 2000

400

2200

500

2400

Q [US GPM]
600

Q [m/h]

TM05 5036 3212


TM05 5036 3912

49

PACO KP, KPV

Curve charts and technical data

KP 8015-3/4 [6-pole]
H
[m]

H
[ft]

KP 8015-3/4

120

60 Hz, n = 1180 rpm

35

/15.0
110

30

100
/13.5

90
25

80
/12.0

70
20
60

15

/10.5

50
/9.0

40
10

NPSH
[ft] [m]
20

30

15
4

20

10

0
0

400

800

1200

1600

2000

2400

2800

3200

3600

P2
[hp]

Q [US GPM]

180
120
100

60
40

160

80

140

/10.5

/12.0

/15.0

/13.5

100

50
/15.0

80
/13.5

60
/12.0

20

40
30
20

/10.5

10

/9.0

0
0

50

70
60

/9.0

40
20

Eff
[%]
90

120
80

400

800

200

1200

1600

400

2000

2400

2800

600

3200

3600

800

Q [US GPM]
Q [m/h]

TM05 5037 3912

P2
[kW]

TM05 5037 3212

NPSH

10

PACO KP, KPV

H
[m]
60

H
[ft]

Curve charts and technical data

KP 8020-5/6 [6-pole]

KP 8020-5/6
60 Hz, n = 1180 rpm

200
/19.25
180

50

/17.94

160

140

/16.62

120

/15.31

100

/14.0

40

30

80

NPSH
[ft] [m]

20
60

30
8

40

20

20

10

10
4
NPSH
0

0
0

250

800

1200

1600

2000

2400

2800

3200

3600

400

90

350
/16.62
/15.31

/19.25

80
70
60

/19.25

200
/17.94

150

/16.62
/15.31

100
50

/17.94

/14.0

250

Q [US GPM]
Eff
[%]

300

100

4400

P2
[hp]

200
150

4000

50
40
30

/14.0
50

20

10
0

400

800

200

1200

1600

400

2000

2400

2800

600

3200

3600

800

4000

4400

Q [US GPM]

1000

Q [m/h]

TM05 5038 3912

P2
[kW]

400

TM05 5038 3212

51

PACO KP, KPV

Curve charts and technical data

KP 1012-1/2 [6-pole]

H
[m]

H
[ft]

KP 1012-1/2

75
22

20

18

60 Hz, n = 1180 rpm

/12.0

70
65

/11.07

60
55

16
50
14

12

/10.15

45
/9.23

40
35

/8.3

10

NPSH
[ft] [m]

30
8

25

25

20

20

15

15

7
6

6
5
4

10

10
NPSH

3
2

P2
[kW]

400

800

1200

1600

2000

2400

2800

3200

3600

Eff
[%]

90

90

60

80

80

50

70

/10.15

20

/12.0

40
30

50
40
30

/10.15

20

/9.23
/8.3

10

70
60

/11.07

20
10

/12.0

/8.3

50
30

/11.07

/9.23

60

Q [US GPM]

P2
[hp]

40

10

0
0

52

4000

400

800

200

1200

1600

400

2000

2400

2800

600

3200

3600

800

4000

Q [US GPM]
1000

Q [m/h]

TM05 5039 3912

PACO KP, KPV

H
[m]

H
[ft]

Curve charts and technical data

KP 1015-3/4 [6-pole]

KP 1015-3/4

120

60 Hz, n = 1180 rpm

/15.37

35
110

30

100

/14.0

90
25

80

/13.0

70

/12.0

60

/11.0

20

15

50

40
10

NPSH
[ft] [m]

30

30
8

20

20

10

10

5
4

0
0

400

800

1200

1600

2000

2400

2800

3200

3600

4000

4400

Q [US GPM]

P2
[hp]
360

240
200

120
80

320

80
/14.0

280
/12.0

/15.37

/13.0

70
60

/11.0

200

50

160

40
/15.37

120
/14.0

80
40

Eff
[%]
90

240
160

40

/11.0

/12.0

/13.0

30
20
10

0
0

400

800

200

1200

1600

400

2000

2400

2800

600

3200

3600

800

4000

4400

Q [US GPM]

1000

Q [m/h]

TM05 5040 3912

P2
[kW]

TM05 5040 3212

NPSH

53

PACO KP, KPV

Curve charts and technical data

KP 1020-3/4 [6-pole]
H
[m]
60

H
[ft]

KP 1020-3/4
60 Hz, n = 1180 rpm

200
/19.6
180

50

/18.25
160

140

/16.75

120

/15.4

100

/14.0

40

30

80

NPSH
[ft] [m]

20
60

60
15

40

40

10

10
20

20
NPSH

0
0

P2
[kW]

250

500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000

Eff
[%]

400

90

/15.4

300

/18.25

/16.75

/19.6
/19.6

/14.0

200

Q [US GPM]

P2
[hp]
350

250

80
70
60

/18.25
150

200

50
/16.75

150
/14.0

100

50

20

10
0

54

30

500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000

200

400

600

800

1000

1200

1400

1600

Q [US GPM]
Q [m/h]

TM05 5041 3912

50

40

/15.4

TM05 5041 3212

100

PACO KP, KPV

H
[m]

H
[ft]

KP 1024-3/4

/24.8

340

60 Hz, n = 1180 rpm

100
320
90

300
/23.0

280
80

Curve charts and technical data

KP 1024-3/4 [6-pole]

260
240

/21.0

70
220
60

200
/19.0
180

50

160

/17.0

140
40
120
30

100

NPSH
[ft] [m]

80
20

60

30

40

20

8
10
20
0

0
0

P2
[kW]

10

NPSH

500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500

Eff
[%]

900

90

600

800

80

500

700
/17.0

600

/21.0

4
2
0

Q [US GPM]

P2
[hp]

/19.0

/24.8

/23.0

/24.8

70
60

400
500

200

400
300

30

/19.0

200
100

40

/21.0

20

/17.0
100

10

0
0

500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500

200

400

600

800

1000

1200

1400

1600

Q [US GPM]

1800

Q [m/h]

TM05 5042 3912

300

50
/23.0

55

PACO KP, KPV

Curve charts and technical data

KP 1220-5/6 [6-pole]
H
[m]

H
[ft]

KP 1220-5/6

70
220

60 Hz, n = 1180 rpm


/20.0

60

200

180
/18.25
50

160

/16.5

140
40
120

/14.75
30

100
/13.0
80

NPSH
[ft] [m]

20
60

60

40

40

15
10

10
NPSH

20

0
0

P2
[kW]

1000

2000

3000

4000

5000

6000

7000

8000

9000 10000 11000

P2
[hp]

Eff
[%]

900

90

800

80

500

700

70

600

/13.0

400

/16.5

/14.75

/20.0

/18.25

60

500

200

50
/20.0

400
/18.25

300

20

/14.75
100

10

/13.0

0
0

56

40
30

/16.5

200
100

Q [US GPM]

600

300

1000

2000

500

3000

4000

5000

1000

6000

7000

1500

8000

9000 10000 11000

2000

2500

Q [US GPM]
Q [m/h]

TM05 5043 3912

20

PACO KP, KPV

H
[m]

H
[ft]

KP 1415-1/2

/15.6

120

Curve charts and technical data

KP 1415-1/2 [6-pole]

60 Hz, n = 1180 rpm

35
110

30

/14.75

100
/13.75
90

25

/13.0
80
/12.0

70
20
60

15

50

40
10

NPSH
[ft] [m]

30

60

20

40

15
5

10
10

0
0

P2
[kW]

20

NPSH

1000

2000

3000

4000

5000

6000

7000

8000

Q [US GPM]

P2
[hp]

5
0

Eff
[%]

200

90

180

80

140

/12.0

140

/13.0

70

/14.75 /15.6
/13.75

60

120
80
60
40

50
/15.6

100

40

/14.75

80

30

/13.75
/13.0

60

20

/12.0
40

20

10

20

0
0

1000

2000

500

3000

4000

1000

5000

6000

7000

1500

8000

Q [US GPM]
2000 Q

[m/h]

TM05 5044 3912

100

160

TM05 5044 3212

120

57

PACO KP, KPV

Bare shaft pump

8. Bare shaft pump


Dimensional sketch

TM04 1827 1108

DNs: Suction flange


DNd: Discharge flange

Dimensions
All dimensions are in inches.
Pump size
2095-1/2
2013-5/6
3095-7/8
3014-7/8
4012-1/2
4012-7/8
4015-9/0
5012-7/8
5015-9/0
6012-3/4
6015-3/4
6019-7/8
6020-3/4
8012-5/6
8015-3/4
8020-5/6
1012-1/2
1015-3/4
1020-3/4
1024-3/4
1220-5/6
1415-1/2

58

DNd
2
2
3
3
4
4
4
5
5
6
6
6
6
8
8
8
10
10
10
10
12
14

DNs
2-1/2
2-1/2
4
4
5
5
5
6
6
8
8
8
8
10
10
12
12
12
14
14
14
16

HZ
12-1/4
15-5/8
13
16-5/8
16-1/8
16-1/8
20
17-5/8
20-3/4
19-3/4
22-3/4
23-3/4
25-5/8
21-5/8
24-3/4
28-13/16
24-3/8
24-3/4
30-3/8
31-3/4
30-13/16
30-1/2

A
12
12
12
12
12
12
12
12
12
12
12-1/4
12
12-1/2
12
12-3/4
25-1/2
12-3/4
18
25-1/2
25-1/2
25-1/2
-

AE
10-1/4
10-1/4
10-1/4
10-1/4
10-1/4
10-1/4
10-1/4
10-1/4
10-1/4
10-1/4
10-1/4
10-1/4
10-1/4
10-1/4
10-1/4
19-3/4
10-1/4
15
19-3/4
19-3/4
19-3/4
-

D
7
8-1/2
8
10
10-1/8
10-1/8
13
14-1/2
16-1/8
16
18-1/4
17
17-3/4
17-1/4
19
20-13/16
19-13/16
20
23-1/16
25
25
-

BP
7
7
7
9-1/4
9-1/4
9-1/4
12
10-1/4
10-1/4
10-1/4
16-1/2
12
12
14
17-1/2
16
17-1/2
12
16
16
16
-

B
8-3/4
8-3/4
8-3/4
11
11-1/8
11-1/8
13-3/4
12
12
12
18
14
14
15-1/2
19-1/2
19-1/4
19-1/2
14
19-1/4
19-1/4
19-1/4
-

DH/SH
3-1/2
3-1/2
4
5
4-7/8
4-7/8
6-1/4
6-1/2
6-1/2
6-1/2
7-1/4
6-3/4
6-3/4
6-3/4
7
7-13/16
8
10
9-11/16
12
12
-

W
12
12
12
14-1/2
14-1/2
14-1/2
14-1/2
16-1/2
17
17
20
19-1/4
21-1/2
20
20-3/8
29-1/2
20-7/8
23-5/8
31-7/16
31-7/16
31-7/16
28-1/2

H
11-16
11/16
11/16
11/16
11/16
11/16
11/16
11/16
11/16
11/16
11/16
3/4
3/4
11/16
11/16
1-1/8
11/16
7/8
1-1/8
1-1/8
1-1/8
-

PACO KP, KPV

Bare shaft pump

Dimensional sketch

TM04 1827 1108

DNs: Suction flange


DNd: Discharge flange

Dimensions
All dimensions are in inches.
Pump size
2095-1/2
2013-5/6
3095-7/8
3014-7/8
4012-1/2
4012-7/8
4015-9/0
5012-7/8
5015-9/0
6012-3/4
6015-3/4
6019-7/8
6020-3/4
8012-5/6
8015-3/4
8020-5/6
1012-1/2
1015-3/4
1020-3/4
1024-3/4
1220-5/6
1415-1/2

K(WxL)

YY

1/4x1/8
8-1/2
8-1/2
1/4x1/8
10
10
1/4x1/8
11
11
3/8x3/16
12
12
3/8x3/16
12
12
3/8x3/16
12
12
3/8x3/16
14-1/16 14-1/16
3/8x3/16
13
13
3/8x3/16
15
14
3/8x3/16
16
14
3/8x3/16
16
15
(X5)3/8x3/16
17
17
(X6)1/2x1/4
1/2x1/4
19
17
3/8x3/16
17
15
3/8x3/16
19
19
5/8x5/16
22
16-5/16
3/8x3/16
19-1/2
19-1/2
1/2x1/4
23
17
3/4x3/8
26
20
3/4x3/8
28
24
5/8x5/16
28
23
25-3/5 21-13/20

G
5/8
5/8
3/4
7/8
7/8
7/8
1
1
1
1
1-1/8
1
1
1-1/8
1-1/8
1-3/8
1-1/8
1-1/8
1-3/8
1-3/8
1-3/8
-

1
2-7/8
1
2-7/8
1 XE 1-3/16
2-7/8
1-1/2
2-3/4
1-1/2
2-3/4
1-1/2
2-3/4
1-1/2
2-3/4
1-1/2
2-3/8
1-1/2
2-3/8
1-1/2
2-3/8
1-3/4
3-11/16
(X5)1-3/4 (X5)3-11/16
(X6)2
(X6)3
2-1/8
3-16/16
1-3/4
3-11/16
1-3/4
3-11/16
2-1/2
4-1/4
1-3/4
3-11/16
2-1/4
6-1/8
3-1/8
6-7/8
3-1/8
9-5/16
2-1/2
4-1/4
2-1/2
-

WS
8-1/2
8-1/2
8-1/2
9-7/8
9-7/8
9-7/8
8-1/2
11-3/8
11-7/8
11-7/8
11-3/4
13-1/4
15-1/2
13
11-5/8
21-1/2
12-1/8
17-5/8
23-3/8
23-3/8
21-1/2
-

CP
PACK
SEAL
21-1/8
19-3/4
21-1/8
19-3/4
21-1/8
19-3/4
26-1/4
24-1/2
26-1/4
24-1/2
26-1/4
24-1/2
26-1/4
24-1/2
30-1/4
30-1/4
31-1/4
31-1/4
31-1/4
31-1/4
36-5/16
36-5/16
(X5)34-11/16 (X5)34-3/16
(X6)35-1/2
(X6)35-1/2
39-1/8
39-1/8
36-5/16
36-5/16
37-1/16
37-1/16
53-11/16
53-11/16
38-1/16
38-1/16
41-1/8
41-1/8
54-11/16
54-11/16
53-1/2
53-1/2
54-3/4
54-3/4
51-7/10
51-7/10

WB
16-3/8
16-3/8
16-3/8
20
20
20
21-3/8
22-1/2
23
23
29
26-1/4
28-1/2
27-3/4
30-1/8
39-1/8
30-5/8
30-5/8
41-5/16
41-5/16
39-1/8
-

59

Copyright Grundfos Holding A/S

ECM: 1109068

GRUNDFOS Pumps Corporation


17100 West 118th Terrace
Olathe, Kansas 66061
Phone: +1-913-227-3400
Telefax: +1-913-227-3500
GRUNDFOS Canada Inc.
2941 Brighton Road
Oakville, Ontario L6H 6C9
Canada
Phone: +1-905 829 9533
Telefax: +1-905 829 9512
Bombas GRUNDFOS de Mexico S.A. de C.V.
Boulevard TLC No. 15
Parque Industrial Stiva Aeropuerto
Apodaca, N.L. Mexico 66600
Phone: +52-81-8144 4000
Telefax: +52-81-8144 4010

The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide.

98432075 0413