You are on page 1of 4

Silver Hydrogen Peroxide

Hydrogen
Peroxide
(H2O2)
.

Silver
(Ag)

A NEW GENERATION ECO-FRIENDLY DISINFECTANT FOR PHARMACEUTICAL

A New Generation
Chlorine Free
Non-Carcinogenic
Non-Mutagenic
Non-Toxic
Non-Pollutant
Non-Staning
Non-Foaming
Tasteless / Colourless / Odourless
Universal Applications
No Alteration to pH Value
Bio-Degradable

IDEAL FOR

AERIAL
DISINFECTION

SURFACE
DISINFECTION

WATER
DISINFECTION

Kamps Ecotech Pvt. Ltd.


e-mail : kampsecotech1@gmail.com / www.kampsecotech.com

INTRODUCTION :
We are one of the leading manufacturers of Silver
Silver Hydrogen Peroxide under
our flagship brand of

SureOxyl
SureOxyl

It is an EcoEco-friendly Nontoxic Biodegradable Biocide.

PRODUCT DESCRIPTION :
SureOxyl
SureOxyl

is a complex formulation of processed Silver, a noble metal and


highly concentrated Hydrogen Peroxide. The Hydrogen Peroxide component
ensures a rapid germ killing effect and the silver component ensures that the
effect is long-lasting. Silver is well known for its oligo-dynamic action (cold
sterilization). The effect of the two components is multiplied by a special

manufacturing process of

SureOxyl
SureOxyl

giving a synergistic effect.

SureOxyl
Salient Features of SureOxyl

A New Generation

Chlorine Free
Non-Carcinogenic
Non-Mutagenic
Non-Toxic
Non-Pollutant
Non-Staining
Non-Inflammable
Non-Foaming
Tasteless
Colorless
Odorless
Universal Applications
No Alteration to Ph Value
Bio-Degradable

The germ killing effect of SureOxyl


SureOxyl is rapid and thorough, even from
low to high temperatures. SureOxyl
SureOxyl generates neither smell nor taste,
has no toxic effect, does not effect the pH value and causes no corrosion.
SureOxyl
SureOxyl when used as per the guidelines causes no irritation to the
eyes, skin or mucous membranes. SureOxyl
SureOxyl is nonpolluting. Its main
component Hydrogen Peroxide does not pollute the effluent, as only
Oxygen and waterare formed. H2O2 H2O + O (nascent form).

Kamps Ecotech Pvt. Ltd.


e-mail : kampsecotech1@gmail.com / www.kampsecotech.com

Air Fumigation/ Aerial Fogging :


This potent biocide is diluted at a given concentration and fumigated using a
fogging machine to disinfect a particular area involved with the processing of drug.
Some common airborne microbes that may contaminate the products are Bacillus
sp., Varicella sp., Influenza virus, Variola virus, Rubeola virus, etc.

Areas of application :
Manufacturing area fumigation
Ingredients mixing area fumigation
Finished Goods Storage area
Fogging Bottling area fumigation
Capsule producing area fumigation
Packaging area fogging
Storage vessels/container fumigation
Clothing and shoes disinfection
Chiller HVAC fumigation
AHU disinfection

Water Disinfection :
A recommended amount of the disinfectant is added to water, making it safe for
use to be used during the preparation of medicines. Some common waterborne
microbes include Entamoeba sp., Vibrio sp., Giardia sp. etc.

Areas of application :

Reverse Osmosis (RO)


Plant sanitation
Cooling Tower Disinfection
Filtration water sanitation

Surface Sanitation :
A diluted concentration of this sanitizer can be used to spray safely on surfaces, or circulated
through pipelines or conveyers for an appropriate contact time. Surfaces are more inclined
towards the growth of variety of microorganisms.
Areas of application :
Tools and equipment sanitation
Clothing and shoes sanitation
Conveyer belt sanitation
Storage Vessels sanitation
Bottle Filling Nozzle disinfection
Filtration devices sanitation
Tables, walls and floor disinfection
Personal Protective Equipment Sanitation

Kamps Ecotech Pvt. Ltd.


e-mail : kampsecotech1@gmail.com / www.kampsecotech.com
PROCEDURE FOR AERIAL DISINFECTION WITH SUREOXYL FOR APPROX. AREA OF 1500 Cu. Ft.
CONCENTRATION : 50% H202 & Silver
DOSAGE
: 3% to 5% (3ml
D.M.Water.)

to

5ml

of

SureOxyl

in

97ml-95ml

of

Distilled

Water

or

MEDIA FOR ISOLATION:


Plate count agar for bacterial isolation.
Potato dextrose agar/ Saborauds agar for fungal isolation.
Air sampler.
PROCEDURE:
Take plate counts before and after fumigation.
Expose 4 plates in the 4 corners of the room and expose 1 plate in the centre i.e. 5 plates.Take
plate counts after 1 & 2 hours of fumigation.
Aerial disinfection is to be carried out with a ULV Sprayer only. As this machine gives a very fine
mist that even penetrates cracks of surfaces ensuring a safe and sterile environment.
SPECIFICATIONS FOR FUMIGATION :
1)

Measure the size of Room to be fumigated in cu. Ft.

2)

Do the Surface / Walls Disinfection with 3%-5% SureOxyl Solution.

3)

Turn On the Air Conditioning System and Maintain the Room Temperature in the Range of 18C to 20C
for 15 to 20 Minutes.

4)

After 20 Minutes Turn Off Air Conditioning System Completely.

5)

Take Food Grade Polythene Bag and Make Solution by Mixing 3ml to 5ml of SureOxyl with 95ml or 93m
of D.M. Water .The dilution should be strictly done with Distilled water or De-mineralized water only to
avoid any precipitation with chlorine which is usually present in raw water.

6)

Place the Food Grade Polythene Bag in to Fogger Tank and ensure that suction pipe is inserted in to
Polythene bag filled with prepared solution in step 5.

7)

Fit the Fogger Tank with Suction Unit.

8)

The angle of the motor is kept at 45 degrees. This can be adjusted with the adjustment knob.

9)

The fogging machine is mounted 2 feet from the floor in one of the Room Corners.

10) Set the timer device to run for 30 Minutes.


11) Put on Main Switch to Start Fogging, (Main Switch is Put ON only after setting time on Timer Device).
12) The flow rate is kept at minimum, varying it depends on the room size and mist required.
13) Ensure that a proper mist is created in the area so that the active ingredient of SureOxyl is suspended in
the atmosphere, thereby giving complete aerial Disinfection.
14) After 30 Minutes of fumigation the room is to be closed for 30 minutes minimum with Air Conditioning
System completely turned off and the plate counts are to be taken after 1 Hour and 2 Hours from the
starting time of Fumigation.
15) The dilution is to be made only during the time of fumigation and the remains of the solution if any
should not be reused. However the remaining solution in the tank if any can be diluted with plane water
and could be used for surface Disinfection.
16) We recommend you to insert the plastic which, is provided to you with the machine in the dilution tank
and then add the solution in it so that there is no contact of the chemical with the tank surface thereby
avoiding any chances of corrosion and further passing on those contaminations in the internal tubes. We
insist that this condition is to be followed strictly which, would enable for better efficiency of the machine
and accurate fumigation results.
17) After every successive fumigation we request you to add plane water and then start the machine for 2
min. This would enable in cleaning the inner tubes and nozzle if chocked.
18) Do not run the machine empty.