Amana Technical Information—Refrigerator

SBIE20TPW P1190708W SBDE20TPW P1190905W


SBIE20TPSW P1190709W SBDE20S4SW P1190906W
• Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing
or repair of this refrigerator.
• Refer to Service Manual RS1000001 for installation, operating, disassembly, ice maker, testing, and
troubleshooting information.

! CAUTION
All safety information must be followed as provided in Service Manual RS1000001.

! WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to refrigerator before servicing,
unless testing requires power. Wires removed during disassembly must be replaced on proper terminals to
insure correct earthing and polarization.

SRD22S3
SRD22VP
Model SRD22VPSE
Capacity 22.1 cu ft
Electrical 115 VAC 60 Hz
Requirements 15 amps
separate circuit
Refrigerant
Type R134a
Amount 5.125 oz
Width 35.75
without side
extrusions
Depth 32.4
with handle
Height 68.4
including top
hinge cap

No Load Performance Controls in Normal Position


Refrigerator Center Freezer
Compartment Food Compartment Food
Percent Run Time Cycles/24 hr Average Average
Kw/24hr “0.4 “10% “25% Temperature “3ƒF Temperature “3ƒF
Ambient ƒF 65ƒ 90ƒ 110ƒ 65ƒ 90ƒ 110ƒ 65ƒ 90ƒ 110ƒ 65ƒ 90ƒ 110ƒ 65ƒ 90ƒ 110ƒ
1 2 4 37 50 100 37 33 0 38 40 40 1 2 2

Temperature Relationship Test Chart


Suction
T-1 Outlet T-1 Inlet T-3 Suction Line Average Total Pressure Head Pressure
“3ƒ F “3ƒ F “7ƒ F Wattage “10% “2 PSIG “5 PSIG
Ambient ƒF 65ƒ 90ƒ 65ƒ 90ƒ 65ƒ 90ƒ 65ƒ 90ƒ 65ƒ 90ƒ 65ƒ 110ƒ
-10 -11 -13 -12 67 90 161 171 1 1 85 135

December 1997 1 RT1300034 Rev. 0


Component Specifications
Part Number Component Specifications
A0282803 Bulb, refrigerator Volt 115/125 VAC
Watt 40 watts

A3079001 Bulb, freezer Volt 115/125 VAC


Watt 40 watts

M0360001 Bulb, cavity Volt 115/125 VAC


Watt 6 watts

C8931604 Capacitor, compressor run Volt 220 VAC


Capacitance 15 Mfd +10%
- 5%

C8931605 Capacitor, auger motor Volt 220 VAC


Capacitance 17 Mfd +10%
- 5%

12049703 Compressor Type Fan Cooled, R134a refrigerant


BTUH 970 BTUH
Volt 115 VAC, 60 Hz
Watt 155 watts
Current
Lock rotor 21.3 amps
Full load 1.5 amps
Resistance
Run windings 2.60 ohms
Start windings 4.35 ohms
D7832702 Control, damper Heater
Volts 20.5 VAC(min), 24 VAC(nom),
27.5 VAC(max)
Watts 2 watts(min), 2.74 watts(nom),
3.6 watts(max)

B2150504 Drier Drier must be changed every time the system is opened for testing or
compressor replacement.

Desiccant (20) 8 x 12 4AXH - 7 M>S> -Grams

10882106 Heater, cavity Volt 115 VAC


Watt 2 “7.5% watts
Resistance 6.61K “7.5% ohms

12049801 Heater, evaporator Volt 115 VAC


Wattage 450 “5% watts
Resistance 29 “5% ohms

RT1300034 Rev. 0 2 December 1997


Part Number Component Specifications
PIN NO. S1 S2 S3 S4 S5 S6 S7 S8 S9 S10
10619401 Keyboard SWITCH FUNCTIONS
1
ENABLE AMANA 25 S1

FREEZER TEMP S2 3
REFRIGERATOR TEMP S3

RAISE TEMP S4 6

LOWER TEMP S5
7
VACATION S6

MAX COOL S7
4
FAST FREEZE S8

ALARM OFF S9 8

DISPLAY OFF S10


5

PERIMETER
STATIC GUARD

SWITCH SCHEMATIC

10114804 Motor, auger Volt 115 VAC, 60 Hz


Rotation (facing shaft) Power to blue and white leads is clockwise
Power to white and orange leads is
counterclockwise
RPM 13 ² 17 RPM
Watt 165 ² 175 watts
Bimetal Cut-out
Opens 266ƒ “9ƒF
Closes 185ƒ “9ƒF
10884501 Motor, condenser Volt 115 VAC, 60 Hz
Rotation (facing end opposite shaft) Clockwise
RPM
Watt 1300 RPM
Current 10.0 watts
Resistance 0.15 amps
220 “10% ohms

10654206 Motor, ECM evaporator fan Volt 115 VAC, 60 Hz


Rotation (facing end opposite shaft) Clockwise
RPM
Watt 3000 RPM
3.4 “10% watts

10377015 Overload, 4TM Volt 115 VAC


Ult. trip amps @ 158°F (70°C) 3.51 amps
Close temperature 142°F (61°C) ± 9°
Open temperature 257°F (125°C) ± 5°
Short time trip (seconds) 10 seconds “ 5
Short time trip amps @77°F (25°C) 14 amps

10097202 Relay, ptc Resistance


3
With power off check:
Across terminals 2 & 3 3 ² 12 ohms
Shorted 0 ohms
Open Very high or infinite ohms
1 2

10166001 Switch, cavity light Type SPST


Volt 125 VAC
Current 4 amps

December 1997 3 RT1300034 Rev. 0


Component Specifications
Part Number Component Specifications
10166002 Switch, crushed/curbed ice Type SPDT
Volt 250 VAC
Current 6 amps

C3680304 Switch, refrigerator light Type DPST NC


Volt 125/250 VAC
Current 5/2.5 amps

C3680312 Switch, freezer light/auger motor interrupt Type SPDT, NO


Volt 125/250 VAC
Current 5/2.5 amps

10533001 Switch, limit, cavity light, and dispensing Type SPSP, NO


10533002 arms Volt 125/250 VAC
10533003 Current 10 amps

D7854104 Switch, photosensitive Rated Load 10 watts


Rated Voltage
Output 125 VDC
Input 125VAC
Operating Voltage Range
Min 108 VAC
Nominal 115 VAC
Max 132 VAC
Resistance 350 (x10k)
C8983701 Thermistor Check resistance across terminals
Refer to table for values. Temp Resistance Temp Resistance
°F (°C) Ohms °F (°C) Ohms
As temperature decreases, -20 (-29) 495600 36 (2) 87510
resitance increases. As
temperature increases, resistance -15 (-26) 418200 38 (3) 82740
decreases.
-9 (-23) 354000 39 (4) 78300

Shorted thermistor will run 100% of -6 (-21) 300600 43 (6) 74100


time.
-4 (-18) 256200 45 (7) 70170
Freezer temperature setting and 5 (-15) 218850 46 (8) 66450
thermistor value determine if
conpressor/condenser fan and 10 (-12) 187470 48 (9) 62970
evaporator fan switches are open
16 (-9) 161040 50 (10) 59670
or closed. Compressor dwell time is
6 minutes. 19 (-7) 138690 55 (13) 52290

Refrigerator temperature setting 25 (-4) 119760 61 (16) 45900


and refrigerator thermistor value 30 (-1) 103680 64 (18) 40410
determine if damper heater switch
is open or closed. 32 (0) 97920 70 (21) 36540

34 (1) 92550 77 (25) 30000


For more information, see Service
Manual.
12017815 Thermostat Volt 120 VAC
Watt 1000 watts
Current 10 amps
Resistance across terminals
Above 48° ± 5°F Open
Below 25° ± 7°F Closed
Between 48° ± 5°F and Will stay in current state (either open or
25° ± 7°F closed) until either 48° ± 6°F or 25° ± 8°F is
reached.

RT1300034 Rev. 0 4 December 1997


Part Number Component Specifications
12195504 Valve, water Volt 120 VAC, 60 Hz
Watt 20 watts
Water pressure (inlet)
Max 120 PSI
Min 20 PSI
Fill rate 140 ± 10 CC's at 7.5 seconds

Adaptive defrost Voltage 115 “10% VAC. 60 Hz


Defrost occurs after predetermined length of compressor run hours. Compressor run time between
defrost changes, or adapts, depending upon recent history of defrost lengths (time it takes for
defrost terminator to open after defrost heater has been turned on).

• Defrost terminator opens at 48ƒF and closes at 25ƒF.


• Compressor run time between defrost (CRTD) will be one of three values under normal operation:
CRTD 1 (8 hours)
CRTD 2 (12 hours)
CRTD 3 (16 hours)
If defrost length is low (DT-LO defined as 19 minutes) indicating small frost load, CRTD for next defrost cycle is
advanced to next level.
If defrost length is high (DT-HI defined as 21 minutes) indicating large frost load, CRTD for next defrost cycle is
lowered to next level.
If defrost length is between 19 and 21 minutes CRTD for the next defrost cycle remains the same.
Initial value at power up CRTD 0 is 4 hours.
• Vacation Mode CRTD equals 72 hours. Vacation Mode CRTD is interrupted with door openings. Defrost interval will
revert back to interval before Vacation Mode. Three things must occur to reach Vacation Mode CRTD:
1) Defrost interval must be CRTD 3 (16 hours).
2) Both refrigerator and freezer doors must have remained closed since last defrost cycle.
3) Defrost thermostat must have opened in less than 19 minutes during last defrost cycle.
• Six minute dwell time occurs after defrost terminator opens before compressor and condenser fan motor will operate.
If defrost thermostat does not open within 29 minutes from start of defrost cycle, adaptive defrost controll will terminate
defrost even though defrost thermostat had not opened.
• To force defrost cycle, with compressor running and one compartment door closed, press either door light switch 4
times within 8 seconds with at least î second between each cycle

Input voltage readings and checks


L1 to L2 line voltage should be present when unit is powered.
K to L2 line voltage should be present with cold control contacts closed.
T to L2 line voltage should be present when cold control contacts are closed, defrost
terminator is closed and adaptive defrost is in defrost mode.
R to L2 line voltage should be present when refrigerator door open (door light switch is closed).
F to L2 line voltage should be present with freezer door open (door light switch is closed).

Output voltage readings and checks


C to L2 line voltage should be present when in refrigeration mode with cold control contacts closed.
D to L2 line voltage present when in defrost mode with cold control contacts closed.

December 1997 5 RT1300034 Rev. 0


Component Specifications

! WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to refrigerator before servicing,
unless testing requires it. Wires removed during disassembly must be replaced on proper terminals to insure
correct earthing and polarization.

Ground

Line Voltage (L1)

Transformer
Neutral (L2)

Freezer Door Open

9309
REF-AMP-03
100-298-03
SN. 2307

Refrigerator Door
10627301

Open

Defrost Heater

Defrost Heater Relay Capacitor


Defrost Terminator

Comp./Cond. Fan
E3 Power Switch

Comp./Cond. Fan Relay

K1

Evaporator Fan
Evaporator Fan Relay

Fresh Food Fan

12 Pin Connector

RT1300034 Rev. 0 6 December 1997


! WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to refrigerator before servicing,
unless testing requires it. Wires removed during disassembly must be replaced on proper terminals to insure
correct earthing and polarization.

Refrigeration and Defrost Component Checks Made at High Voltage Board


Low voltage board input W1 to D11 approximately -25 VDC
High voltage board input E10 to E9 (Neutral) or ground approximately 120 VAC

Compressor/condenser fan motor “ON” = E4 to E9 (Neutral) ground approximately 120 VAC


“OFF” = E4 to E9 (Neutral) or ground

Compressor/condenser fan motor “CLOSED” = R7 to ground approximately -11 VDC


relay “OPEN” = R7 to ground approximately -25 VDC

Evaporator fan motor relay “CLOSED” = R8 to ground approximately -11 VDC


“OPEN” = R8 to ground -25 VDC

Evaporator fan motor “ON” = E2 to E9 (Neutral) or ground approximately 120 VAC


“OFF” = E2 to E9 (Neutral) or ground 0 VAC

Defrost heater “ON” = E6 to E9 (Neutral) or ground approximately 120 VAC


“OFF” = E6 to E9 (Neutral) or ground 0 VAC

Defrost heater relay “CLOSED” = R9 to ground approximately -11 VDC


“OPEN” = R9 to ground approximately -25 VDC

Defrost terminator “CLOSED” = E5 to E9 (Neutral) or ground approximately 120 VAC


“OPEN” = E5 to E9 (Neutral) or ground 0 VAC

Fresh food fan output voltage “ON” = E1 to ground approximately -25 VDC
High voltage board to fresh food fan “OFF” = E1 to ground 0 VDC

Fresh food fan input voltage “ON” = R10 to ground approximately -11 VDC
Signal to high voltage board from
low voltage board “OFF” = R10 to ground approximately -25 VDC

Filament voltage at pins 11 and 12 = less than 5 VAC

December 1997 7 RT1300034 Rev. 0


Component Specifications

! WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to refrigerator before servicing,
unless testing requires it. Wires removed during disassembly must be replaced on proper terminals to insure
correct earthing and polarization.

! CAUTION
High Voltage

12354201 PRINTED IN U.S.A.

RT1300034 Rev. 0 8 December 1997


! WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to refrigerator before servicing,
unless testing requires it. Wires removed during disassembly must be replaced on proper terminals to insure
correct earthing and polarization.

! CAUTION
High Voltage

12156301 REV 00 PRINTED IN U.S.A.

December 1997 9 RT1300034 Rev. 0


0034 Rev. 0

omponent Specifications omponent Specifications


! WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to refrigerator before servicing,
unless testing requires it. Wires removed during disassembly must be replaced on proper terminals to insure
correct earthing and polarization.

12178201 REV00 PRINTED IN U.S.A.

RT1300034 Rev. 0 10 December 1997


! WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to refrigerator before servicing,
unless testing requires it. Wires removed during disassembly must be replaced on proper terminals to insure
correct earthing and polarization.

December 1997 11 RT1300034 Rev. 0