You are on page 1of 4

AL-BALQA’ APPLIED UNIVERSITY ‫جامعة البلقاء التطبيقية‬

‫كلية الهندسة التكنولوجية‬


Faculty of Engineering Technology

AC Motor Drive Laboratory


Report on

Control Of DC Motor
Prepared by
Mohammed Mofleh Salem

Supervised by
Dr. Rateb Alesa`a

Date of doing the experiment: 18/10/2010


Date of submission: 25/10/2010

FET / Vice Dean for Academic Affairs 20/2/2009. 1


AL-BALQA’ APPLIED UNIVERSITY ‫جامعة البلقاء التطبيقية‬
‫كلية الهندسة التكنولوجية‬
Faculty of Engineering Technology

Objectives:
* check contactor, timer, and push button unit.
* check power supply connection.

Equipment:
1. DC machine.
2. Contactor Units
3. Timers
4. Push button station
5. AC/DC power supply
Connection leads

Assignment:
1. Starting of DC shunt motor (principle of time one step).
2. Dynamics braking of DC shunt motor.
3. Reversing of DC shunt motor.

Block Diagram:
1) Starting of DC shunt motor (time principle one step)

FET / Vice Dean for Academic Affairs 20/2/2009. 2


AL-BALQA’ APPLIED UNIVERSITY ‫جامعة البلقاء التطبيقية‬
‫كلية الهندسة التكنولوجية‬
Faculty of Engineering Technology

When we press the push button ON the power will arrive to K1


K1 will change the position of the contactors and the power will arrive to the timer KT, after a
few seconds the timer will be ON and change its contactors so the k2 will be ON and change the
position of the contactors and R will go out and the motor still running.

2) Dynamic Braking DC shunt motor

When we press the push button ON the power will arrive to K1


K1 will change the position of its contactors and motor will run. After that when pressing OFF
button the K1 will open its contactors and KT, K2 will be ON and the R will be in the circuit
after seconds the timer contactor will be activated (open) and the motor stop.

FET / Vice Dean for Academic Affairs 20/2/2009. 3


AL-BALQA’ APPLIED UNIVERSITY ‫جامعة البلقاء التطبيقية‬
‫كلية الهندسة التكنولوجية‬
Faculty of Engineering Technology

3) Reversing of DC shunt motor

When ON1 button pushed the coil K1 change


its contactors position and the motor will run at
forward direction but when OFF button pushed
the motor will stop and pushing ON2 will
apply a power at coil K2 and change contactor
position and the motor run at backward
direction and so… .

FET / Vice Dean for Academic Affairs 20/2/2009. 4