You are on page 1of 31

LY

N
O
NG
NI
AI
TR
AL
RN
TE
IN
TG
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


2

TOPICS
LY
N
O
1. HF System

NG
2. VHF System
NI
AI
3. Call System
TR
AL
4. Interphone

RN5. ACARS

TE
IN
TG
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


3

Audio Selector Panel LY


N
Radio/Inter
Radio/Inter switch
O
switch

NG
NI Mike
Mike Selector
Selector P/B
P/B

AI
Connects
Connects boom/oxygen
boom/oxygen mikemike to
to TR
the radio, selected
selector button
or
button
or connects
connects to
to the
by the

the flight
flight
mike
the radio, selected by the mike
selector

AL
interphone system
interphone system

RN •Press
•Press and
•Rotate
Reception
Reception knob
and release
CW
release for
to
knob
for reception,
adjust
reception,
volume

TE •Rotate CW to adjust volume

Allows
be
Voice/Indent
Allows voice
voice or
be heard
IN
Voice/Indent switch
switch
or identification
identification signals
signals to
to
heard

TG
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


4

1. HF System LY
N
HF antenna and two couplers
O
NG
NI
AI
•A two-way long range communication with ground
station or other A/C

TR
•Frequency 2-29.999 MHz, space 1 kHz

AL •Simultaneous operation of both receivers

RN
TE •Only one transmitter can be operated at a time and
both receivers will be mute

IN
TG
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


5

HF interconnection schematic
LY
N
HF Antenna O
NG
NI
HF Antenna
Tuner1 Interlock

AI HF Antenna
Tuner2

Flight Interphone
TR
SELCAL1 AL SELCAL2

RN
HF Transceiver 1 HF Transceiver 2

TE
IN
TG
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


6

HF Operation
LY
N
Frequency select- MHz O
Frequency select-10 kHz

NG
NI
Frequency select- 100 kHz
AI Frequency select-1 kHz

TR
AL
•Whenever the equipment has been switched off, rotating the 10 kHz
frequency selector one digit off freq. and then back to the desired freq.

RN
•Wait 3-8 secs for the antenna coupler to tune (characterized by a 1000 Hz tone)

TE
IN
•AM or SSB selection depending on ground station

G
•No Sensitivity or Squelch switch
T
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


7

HF Operation
LY
N
O
NG
NI Loudspeakers

AI
TR
AL
RN
TE
IN
TG
R Transition via Hand Mike

FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


8

LY
N
O
OR
NG
NI
AI
TR
AL
RN
TE
IN
TG
R Transition via Boom mike/Oxygen mask

FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


9

2. VHF System
LY
N
O
NG
NI
AI
TR
AL
RN
TE
•A two-way short range communication with ground station or other A/C

IN
G
•Frequency 118-135.975 MHz, space 25 kHz

T
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


10

VHF operation
LY
N
Ready Light Transfer Switch
O
NG
NI
LH freq. read out

AI RH freq. read out

TR
AL Frequency Selector L-R

RN
TE
IN
TG
Transition via Hand Mike
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


11

LY
N
O
NG
OR

NI
AI
TR
AL
RN
TE
IN
TG
R Transition via Boom mike/Oxygen mask

FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


12

3. Call System
LY
N
O
NG Cabin Call
Mechanic Call
•If pressed a horn in the nose
NI •If pressed a chime is actuated
and a light is illuminated at
wheel is actuated
•Comes on blue and buzzer
AI the selected station
•Comes on blue and buzzer
sounds if called from
ground mechanic
TR sounds if called from a cabin
attendant’s station

SELCAL AL
RN
TE
IN
TG Call Panel

R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


13

Mechanic Call
LY
N
O
NG
NI
AI
TR
AL
RN Cockpit to Nose gear

TE
IN
TG
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


14

LY
N
O
NG CALL

Cockpit Call
NI CALL

AI ON
CALL

TR VHF 1
HF 1

VHF 2
CALL

CALL

AL HF 2

VHF 3

CALL

Headset Jack

RN
TE Nose gear to Cockpit

IN
TG
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


15

Cabin Call
LY
N
O
CALL

NG
CALL

NI
ON
CALL

AI
VHF 1
HF 1
CALL

TR
VHF 2
HF 2

VHF 3
CALL

AL
CALL

RN
TE Cockpit to Cabin
AFT DOOR

IN
TG
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


16

LY
N
O
G
CALL

I N
CALL

ON

I N CALL

R
VHF 1
HF 1
A CALL

T
VHF 2
HF 2
CALL

AL VHF 3

CALL

RN
TE Cabin to Cockpit

IN
TG
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


17

SECAL
LY
N
CALL
O
ü
SELCAL Decoder
Incoming Code = A/C SELCAL Code
NG
NI CALL

I
ON
CALL

RA VHF 1
HF 1
CALL

T VHF 2
HF 2
CALL

AL VHF 3

CALL

RN
TE
IN
•Incoming message containing A/C’s correct dedicated code alerts the SELCAL system

TG
•Provides visual and intermittent buzzer sound to alert pilots

R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


18

4. Interphone
LY
N
Flight Interphone Cabin Interphone
O
Service Interphone

NG
NI
AI
TR
AL
RN
TE
IN
TG Passenger
Passenger Address
Address

R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


19

Flight Interphone
LY
N
O
NG
NI
AI
TR
AL
RN
TE •Among pilots

IN •Between pilots and ground mechanic during preflight

TG
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


20

LY
N
O
NG
NI
AI
TR
AL
RN
OR TE OR

IN
TG
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


21

Cabin Interphone
LY
N
O
NG
I
CALL

CALL

I N
ON

VHF 1
CALL

CALL

RA
HF 1

VHF 2 CALL T
HF 2

VHF 3
CALL

AL
RN
TE
IN
TG •Between cockpit crews and cabin crews

R •Among cabin crews

FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


22

Service Interphone
LY
N
O
NG
NI
AI
TR
AL
RN
TE
IN
G
•Between flight deck and 16 external A/C stations during maintenance

T
•Use PA handset only, no call signal
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


23

Passenger Address
LY
N
O
•Announcements from cockpit crew or cabin crew to

G
passengers via cabin loudspeakers

N
NI
•Priority announcements is: Cockpit> Cabin> Tape reproducer

AI
TR
CALL

AL
ON
CALL

CALL

RN
VHF 1
HF 1

VHF 2
CALL

CALL
TE OR

IN
HF 2

VHF 3
CALL

TG
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


24

5. ACARS
LY
N
O
G
•Aircraft Communications Addressing and Reporting System

N
NI
Uplink
Aircraft
Equipment Downlink
AI
•Direct exchange of data between the A/C and the airline
ground-based computer through center VHF radio (Data

R
link Service Provide-DSP)

T
AL
Uplink
DSP

R
Downlink
N
TE
IN
TG
Ground Processing System

R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


25

DSP
LY
N
O
NG
NI
AI
TR
AL
RN
TE
IN
TG
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


26

ACARS Equipment
LY
FMC1 FMC2 N
O
VHF3

NG
NI
AI
TR
A L ACARS Management Unit
(ACARS MU)

R N MIDU&Printer
Cabin
Cabin System
System

TE
I N DFDAU
DFDAU

TG
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


27

FMC1 FMC2 LY
N
VHF3
•ACAR MU: Control
O
transmission/reception of ACARS

NG message through the VHF receiver

NI
ACARS Management Unit
(ACARS MU)
AI •Control frequency base on A/C

Cabin
Cabin System
System
MIDU&Printer

TR position data

DFDAU
DFDAU

AL •Generate automatic and manual


data processing

RN •Automatically generate downlink

TE messages

IN
•FMCs: Retrieving of the flight data
•Generate ACARS alert conditions

functions
TG
•MIDU: Controlling and using of ACARS related

R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


28

Controls and Indicators


LY
N
VHF-3 control panel
O
NG
NI
Printer MIDU

AI
TR
AL
RN ACARS control panel

TE
IN
TG
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


29

Page Description
LY
N
O
NG
NI
AI
TR
AL
RN
TE
IN
TG
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


30

Page Description
LY
N
O
NG
NI
AI
TR
AL
RN
TE
IN
TG
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com


31

LY
N
O
NG
NI
AI
The AEnd… TR
L
RN
TE
IN
TG
R
FO A300-600 GROUND CONVERSION by Prapaipat T./BG

PDF created with pdfFactory Pro trial version www.pdffactory.com

You might also like