  The  document  aims  to  describe  various  timers  implemented  in  the 
GSM  network.  While  reasonable  efforts  have  been  made  to  assure  the 
accuracy  of  this  document,  PMCL  assumes  no  liability  resulting  from  any 
inaccuracies  or  omissions  in  this  document,  or  from  the  use  of  the 
information obtained herein. 
 
PMCL  reserves  the  right  to  make  changes  from  time  to  time  in  the 
content  of  this  document  and  hereof  with  no  obligation  to  notify  any 
person of revisions or changes.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2
Mobilink Confidential Property 

TABLE OF CONTENTS 
 
1.0      Introduction  5 
2.0      What does the manual cover?  5 
3.0      Why the need to study timers?  5 
4.0      Timer Categorization  6 
  4.1    Entity Based Categorization  6 
  4.2    Process Flow Based Categorization  6 
5.0      Breakdown   7 
6.0      GSM Timers  9 
  6.1    Call Setup  10 
    6.1.1  T3120  12 
    6.1.2  T3126  13 
    6.1.3  T3101  14 
  6.1.4  T3230  15 
  6.1.5  T303  16 
  6.1.6  T310  17 
  6.1.7  T11  18 
  6.1.8  T10  19 
  6.1.9  T313  20 
  6.1.10  T3107  21 
  6.1.11  T1  22 
6.2    Call Clearing  23 
  6.2.1  T13  23 
  6.2.2  T3111  24 
  6.2.3  T3109  25 
  6.2.4  T3110  26 
6.3    Handover  27 
  6.3.1  T3103  28 
  6.3.2  T8  29 
  6.3.3  T7  30 
  6.3.4  TQHO  31 
  6.3.5  T3121  32 
6.4    GPRS  32 
  6.4.1  T3182  33 
  6.4.2  T3164  34 
  6.4.3  T3198  35 
  6.4.4  T3180  36 
  6.4.5  T3190  37 
  6.4.6  T3192  38 
  6.4.7  T3200  39 

3
Mobilink Confidential Property 

  6.4.8  T3162  40 


  6.4.9  T3168  41 
  6.4.10  T3170  42 
  6.4.11  T3172  43 
  6.4.12  T3176  44 
  6.4.13  T3188  45 
  6.4.14  T3322  46 
  6.4.15  T3380  47 
  6.4.16  T3385  48 
  6.4.17  T3386  49 
  6.4.18  T3390  50 
  6.4.19  T3395  51 
  6.4.20  T3158  52 
  6.4.21  T3166  53 
  6.4.22  T3169  54 
  6.4.23  T3174  55 
  6.4.24  T3182  56 
  6.4.25  T3178  57 
  6.4.26  T3184  58 
  6.4.27  T3191  59 
  6.4.28  T3193  60 
  6.4.29  T3195  61 
  6.4.30  T3310   62 
  6.4.31  T3312  63 
  6.4.32  T3314  64 
  6.4.33  T3321  65 
6.5    Miscellaneous  66 
  6.5.1  T3210  66 
  6.5.2  T3128  67 
  6.5.3  T3211  68 
  6.5.4  T3212  69 
  6.5.5  T3220  70 
7.0      Compiled List  71 
  7.1    Motorola Timers List  71 
  7.2    Alcatel Timers List  73 
  7.3    Huawei Timers List  76 
 
 
 
 
 

4
Mobilink Confidential Property 

1.0    INTRODUCTION 
 
Like any other wireless technology with a limited  pool of  resources, 
GSM resource allocation and termination depends primarily on timers. The 
functionality  and  protocols  may  vary,  but  the  presence  of  timer  based 
signaling  and  resource  allocation  is  ubiquitous.  Timer  implementation  is 
present in each domain of the GSM system from MS to NSS end. 
 
2.0    WHAT DOES THIS MANUAL COVER? 
 
This document aims to describe all the major BSS timers involved in 
the GSM architecture. The timers are categorized into different subgroups, 
depending upon their parent entity and the process flow they are involved 
in. The document proceeds further by giving a detailed explanation of each 
timer along with its implementation in the PMCL network. 
 
3.0    WHY THE NEED TO STUDY TIMERS? 
 
As  already  highlighted,  timer  implementation  is  present  throughout 
the GSM architecture. Timers effect call setup procedures, handovers, call 
clearing,  data  usage  (GPRS),  VAS  facilities;  in  short,  everything  that  a 
customer might do to access and utilize the GSM network. Therefore, for a 
high  quality  network,  it  is  imperative  to  have  impeccable  timing.  Precise 
synchronization  and  timing  improves  call  signal  hand  over  performance 
between  base  stations;  and,  as  an  added  benefit,  reduces  customer 
complaints. GSM networks are dependent on strict synchronization of the 
base stations to facilitate call handovers. 
 
Furthermore,  the  reason  for  a  deep  understanding  of  timers  is  also 
re‐enforced by the multi vendor implementation present at all levels of the 
network.  Such  a  scenario  demands  all  database  discrepancies  to  be 
eliminated to ensure coherence and inter‐vendor compatibility. 
 
 
 
 

5
Mobilink Confidential Property 

4.0    TIMER CATEGORIZATION 
 
4.1    ENTITY BASED CATEGORIZATION
 
As  highlighted  earlier  there  are  different  ways  of  categorizing  timers.  One 
categorization  can  be  done  on  the  basis  of  entity  which  includes  the 
following categories: 

 
 
 
4.2   PROCESS FLOW BASED CATEGORIZATION
 
A  further  classification  of  GSM  timers  can  be  done  on  the  basis  of 
process  flows  involved  in  the  system.  These  include  the  following  basic 
categories: 
 
• Call Processing  
Call Setup 
Call 
Release 
• Handovers 
• GPRS 
• Miscellaneous  
 
 

6
Mobilink Confidential Property 

5.0    BREAKDOWN [PHASE 1] 
 
The  task  of  documenting  the  GSM  timers  is  not  an  easy  paced 
procedure.  The  project  is  divided  into  two  phases.  The  first  phase 
comprised of the research for all the timers involved from MS to BSS as per 
the  international  GSM  standards.  In  the  second  phase,  vendor 
implementations of these timers were taken into consideration. A complete 
overview of all the timers involved in Phase 1 is as under: 
 
Default 
Timer  Call Flow  Vendor  Timer's Name  Category  Range 
Value 
Motorola  MS Timer MS Timer ‐  ‐
Alcatel  MS Timer MS Timer ‐  ‐
T3120  Call Setup 
Min is RACH  Min is RACH 
Huawei  T3120  MS Timer 
T+2S; MAX 5  T+2S ;MAX 5 
Motorola  MS Timer MS Timer ‐  ‐
Alcatel  MS Timer MS Timer ‐  ‐
T3126  Call Setup 
Min is RACH  Min is RACH 
Huawei  T3126  MS Timer 
T+2S MAX 5  T+2S MAX 5 
Motorola  wait_indication_parameter BTS none  0 to 255 sec
T3122  Call Setup  Alcatel  T3122 MS Timer ‐  0 to 255 sec
Huawei  T3122 Cell Timer 10 sec  0‐255  sec
Motorola  rr_t3101 BTS 5 sec  0 to 1000 sec
T3101  Call Setup  Alcatel  T3101 BSC level 3 sec  0 to 25.5 sec
Huawei  T3101 Cell Timer 3 sec  0.5 to 60 sec
Motorola  MS Timer MS Timer ‐  ‐
T3230  Call Setup  Alcatel  MS Timer MS Timer ‐  ‐
Huawei  T3230 MS Timer 15 sec  15 sec
Motorola  MS Timer MS Timer ‐  ‐
T303  Call Setup  Alcatel  MS Timer MS Timer ‐  ‐
Huawei  T303 MSC Timer 20 sec  ‐
Motorola  MS Timer MS Timer ‐  ‐
T310  Call Setup  Alcatel  MS Timer MS Timer ‐  ‐
Huawei  T310 MSC Timer 20 sec  ‐
Motorola  bssmap_t11 BTS 28 sec  0 to 1000 sec
T11  Call Setup  Alcatel  T11 BSS 6 sec  0 to 19  sec
Huawei  T11 BSC Timer 8 sec  1 to 30 sec
Motorola  bssmap_t10 BTS 28 sec  0 to 1000 sec
T10  Call Setup  Alcatel  bssMapT10 BSS 14 sec   ‐
Huawei  T10 BSC Timer 7 sec  1 to 20 sec
Motorola  ‐ MSC timer ‐  ‐
T313  Call Setup  Alcatel  T313 MS Timer ‐   ‐
Huawei  T313 MSC Timer 30 sec  30 sec
Motorola  bssmap_t8 BTS 28 sec  0 to 1000 sec
T8  Handover  Alcatel  bssMapT8 BSS 14 sec  0 to 25.5 sec
Huawei  T8 Cell Timer 10 sec  0.5 to 60 sec
T3103  Handover  Motorola  rr_t3103 BTS 30 sec  0 to 1000 sec

7
Mobilink Confidential Property 

Alcatel  T3103 BSS 16.5  sec  0 to 25.5 sec


Huawei  T3103 Cell Timer 10 sec  0.5 to 60 sec
0 to 1000000 
Motorola  bssmap_t1  BSC  30 sec 
msec 
T1  GPRS 
Alcatel  bssMapT1 BSS  16 sec  10 to 25.5 sec
Huawei  T1 BSC Timer 30 sec  1 to 300  sec
Motorola  bssmap_t13 BSC 40 sec  0 to 1000 sec
T13  Call Clearing  Alcatel  bssMapT13 BSS 15 sec  0 to 6553.5 sec
Huawei  T13 BSC Timer 150 sec  1 to 300 sec
Motorola  bssmap_t7 BSC 30 sec  0 to 1000 sec
T7  Handover  Alcatel  bssMapT7 BSS 5 sec  0 to 20  sec
Huawei  T7 Cell Timer 10 sec  0.5 to 60 sec
Motorola  bssmap_tqho BSC 30 sec  0 to 1000 sec
TQHO  Handover  Alcatel  T_QHO BSS 3 sec  0 to 20 sec
Huawei  TQHO BSC Timer 8 sec  1 to 30 sec
rr_t3111_sd BTS 1.5 sec  0 to 1000 sec
Motorola 
rr_t3111_tch BTS 1.5 sec  0 to 1000 sec
T3111  Call Clearing 
Alcatel  T3111 BSS 0.5 sec  0 to 2  sec
Huawei  T3111 Cell Timer 1 sec  0.5 to 60 sec
Motorola  rr_t3109 BTS 14.4 sec  0 to 1000 sec
T3109  Call Clearing  Alcatel  T3109 BSS 12 sec  0 to 35 sec
Huawei  T3109 Cell Timer 27 sec  1‐35 sec
Motorola  ‐ MSC Timer ‐  ‐
T3121  Handover  Alcatel  T3121 BSS 14 sec  0 to 25.5 sec
Huawei  T3121 Cell Timer 10 sec  0.5 to 60
Motorola  RRSM_T10 BTS 28 sec  0 to 1000 sec
T3107  Call Setup  Alcatel  T3107 BSS 14 sec  0 to 25.5 sec
Huawei  T3107 Cell Timer 10 sec  0.5 to 60 sec
Motorola  lapd_t200_timer BTS 2.5 sec  1.4 to 5 sec
T200  Configurational  Alcatel  T200 BSS 0.3 sec  0.3 to 1 sec
Huawei  T200 (FACCH/F/H) Cell Timer 0.05 sec  1 to 0.255 sec
Motorola  ‐ ‐ ‐  ‐
T9101  Call Clearing  Alcatel  T9101 Network  10 sec  0 to 6553.5 sec
Huawei  SCCP_TREL(s) BSC Timer 15 sec  10 to 20 sec
Motorola  ‐ ‐ ‐  ‐
Alcatel  T9104 BSS 2 sec  0 to 25.5 sec
T9104  Call Clearing 
TCLEARREQ(BSC) BSC Timer 5 sec  1 to 150 sec
Huawei 
TNT3(MSC) MSC Timer 6 sec  1 to 120 sec
Motorola  ‐ ‐ ‐  ‐
T9108  Call Clearing  Alcatel  T9108 Network  3 sec  0 to 6553.5 sec
Huawei  ‐ ‐ ‐  ‐
Motorola  MS Timer MS Timer ‐  ‐
T3110  Call Clearing  Alcatel  MS Timer MS Timer ‐  ‐
Huawei  T3110 MS Timer 10 sec  0.5 to 60 sec
 
 
 
 

8
Mobilink Confidential Property 

6.0    GSM TIMERS 
The  description  of  GSM  Timers  in  isolation  can  often  lead  to 
confusion  for  the  engineer.  To  ensure  uniformity  and  ease  of 
understanding, a format has been used to describe in detail each timer. The 
format is as given below. 
 
y Timer Name 
 
This  field  will  include  the  name  of  the  Timer,  as  used  in  the 
international GSM standards.  
 
y Category  
 
This  field  will  indicate  the  placement  of  the  timers  in  the  GSM 
network. For Example either a timer is used in Call Setup procedures 
or it is used to administer a Handover.  
 
y Start Event 
 
This field will include the event which triggers the timer. 
 
y Stop Event  
 
This field will include the event upon which, the timer stops.  
 
y Expiry Event  
 
This is the event which takes place, once the timer has expired.  
 
 
Optional  field  include  the  values  used  by  the  vendors,  ranges  and 
default values.  

9
Mobilink Confidential Property 

6.1   CALL PROCESSING 
 
This  section  deals  with  timers  that  essentially  make  up  the  call 
request and call setup procedure. A skim through the call flow shown below 
will help give the reader an idea of the positioning of the timers and their 
importance. 
 
Details  for  each  of  the  mentioned  timers  will  follow  along  with 
suitable information on them. 
 
 
 

 
 
 
 
 
 
 

10
Mobilink Confidential Property 

 
Call Processing (Contd...)  
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

11
Mobilink Confidential Property 

6.1.1   T3120 
 
Category  
 
This  timer  is  included  in  the  Call  Request  procedure  which  starts  with  the 
RACH request.  
 
Start Event 
 
This timer starts when the RACH request is sent to the network.  
 
Stop Event  
 
The timer stops once the RACH acknowledgment is received.  
 
Expiry Event 
 
Once  the  timer  expires,  the  RACH  request  is  re‐Transmitted  on  the  air 
interface.  
 
 
The default value for this timer is 10 seconds.  
 
This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is  not 
applicable.  

12
Mobilink Confidential Property 

6.1.2  T3126 
 
 
Category  
 
This  timer  is  included  in  the  Call  Request  procedure  which  starts  with  the 
RACH request.  
 
Start Event 
 
This  timer  starts  when  the  maximum  amount  of  Channel  requests  have 
been sent by the MS.  
 
Stop Event  
 
The timer stops when immediate assignment message is received from the 
BSS.  
 
Expiry Event 
 
Once  the  timer  expires,  the  procedure  for  immediate  assignment  is 
aborted.   
 
The value of this timer depends on the setting of RACH re‐transmission.  
 
This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is 
unavailable.  

13
Mobilink Confidential Property 

6.1.3   T3101 
 
Category  
 
This  timer  is  included  in  the  Call  Setup  procedure  which  starts  with  the 
immediate assignment procedure.  
 
Start Event 
 
This  timer  starts  when  the  immediate  assignment  message  is  sent  to  the 
MS by the BSS entity.  
 
Stop Event  
 
The timer stops when the Establish indication message is sent by the MS to 
the BSS entity. 
 
Expiry Event 
 
Once the timer expires, the procedure for call setup is aborted. 
 
The vendor based values for this timer are given below for reference. 
 

  Motorola   Alcatel   Huawei 

T3101  2 sec  3 sec  3 sec 

14
Mobilink Confidential Property 

6.1.4  T3230 
 
Category  
 
This  timer  is  included  in  the  Call  Setup  procedure  which  starts  with  the 
immediate assignment procedure.  
 
Start Event 
 
This timer starts when the CM service request is sent by the MS to the BSS 
entity  
 
Stop Event  
 
The timer stops when the MS receives the message of CM Service request 
acknowledged. It is also stopped in case a CM service reject is received. 
 
Expiry Event 
 
Once the timer expires, the release indication is provided to the BSS entity. 
 

The default value for this timer is 15 seconds 

This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is 
unavailable.  

 
 

15
Mobilink Confidential Property 

6.1.5   T303 
 
Category  
 
This  timer  is  included  in  the  Call  Setup  procedure  which  starts  with  the 
immediate assignment procedure.  
 
Start Event 
 
This timer starts when the UA frame for the SDCCH connection is received 
by the MS.  
 
Stop Event  
 
The timer is stopped when the CM service request is sent by the MS. 
 
Expiry Event 
 
In case of an expiry event of this timer, the Call setup procedure is aborted. 
 

The default value for this timer is 20 seconds 

This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is 
unavailable.  

 
 
 
 

16
Mobilink Confidential Property 

6.1.6   T310 
 
 
Category  
 
This  timer  is  included  in  the  Call  Setup  procedure  which  starts  with  the 
immediate assignment procedure.  
 
Start Event 
 
This Timer starts when the MS receives Call proceeding message.  
 
Stop Event  
 
The  timer  stops  once  the  Altering  procedure  begins  and  the  call  is 
established. 
 
Expiry Event 
 
In case the timer expires and the altering procedure has not begun, the call 
setup procedure is aborted and No user Responding message is sent.  
 
 
The default value for this timer is 20 seconds 

This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is 
unavailable.  
 

 
 

17
Mobilink Confidential Property 

6.1.7  T11 
 
Category  
 
This  timer  is  included  in  the  Call  Setup  procedure  which  starts  with  the 
immediate assignment procedure.  
 
Start Event 
 
This  timer  starts  when  an  assignment  resource  request  is  queued  by  the 
BSS entity.  
 
Stop Event  
 
The timer is stopped when the resource request is allocated a resource by 
the BSS entity.  
 
Expiry Event 
 
Once the timer expires, the resource request is rejected and the call setup 
procedure is aborted. 
 
The vendor based values for this timer are given below for reference. 

  Motorola   Alcatel   Huawei 

T11  10 sec  6 sec  8 sec 

 
Note: If the value of T11 timer is kept more than the value of assign_successful timer 
[Motorola], this could lead to potential masking of Call Setup Blocking. CSSR  

18
Mobilink Confidential Property 

6.1.8  T10 
 
Category  
 
This  timer  is  included  in  the  Call  Setup  procedure  which  starts  with  the 
immediate assignment procedure.  
 
Start Event 
 
This  timer  starts  when  assignment  request  is  sent  to  the  MS  by  the  BSS 
entity.  
 
Stop Event  
 
The timer is stopped when the assignment complete message is sent by the 
MS to the BSS entity.  
 
Expiry Event 
 
Once  the  timer  expires,  the  assignment  request  is  released  and  the  call 
setup procedure is aborted. 
 
The vendor based values for this timer are given below for reference 
 
  Motorola   Alcatel   Huawei 
T10  11 sec  14 sec  7 sec 
 
 
 
Note: If the value of T10 timer is kept more than the value of assign_successful timer 
[Motorola],  this  could  lead  to  potential  masking  of  RF_Losses_SD  & 
Intra_cell_HO_Losses.  
 

19
Mobilink Confidential Property 

6.1.9 T313 
 
Category  
 
This  timer  is  included  in  the  Call  Setup  procedure  which  starts  with  the 
immediate assignment procedure.  
 
Start Event 
 
This  timer  starts  when  the  call  connect  message  is  sent  to  the  call 
originating mobile. 
 
Stop Event  
 
The  timer  stops  when  connect  acknowledge  message  is  received  by  the 
network entity from the MS.  
 
Expiry Event 
 
In case of an expiry even of this timer, the call setup procedure is aborted 
and the call is released. 

20
Mobilink Confidential Property 

6.1.10  T3107 
 
Category  
 
This  timer  is  included  in  the  Call  Setup  procedure  which  starts  with  the 
immediate assignment procedure.  
 
Start Event 
 
This timer starts when the assignment command is sent by the BSS entity to 
the MS. 
 
Stop Event  
 
The  timer  is  stopped  when  the  Assignment  complete  message  is  received 
by BSS entity. 
 
Expiry Event 
 
In case of an expiry event of this timer, an assignment failure command is 
sent and the channels are released. 
 
 
The vendor based values for this timer are given below for reference 

  Motorola   Alcatel   Huawei 


T3107  11 sec  14 sec  10 sec 

21
Mobilink Confidential Property 

6.5.11 T1 
 
Category  
 
This  timer  is  included  in  the  Call  Setup  procedure  which  starts  with  the 
immediate assignment procedure.  
 
Start Event 
 
This timer starts when a blocking message is sent by the BSS entity to the 
MSC entity in case of non‐usable A interface timeslot.  
 
Stop Event  
 
The timer is stopped when a Blocking acknowledgment message is received 
by the BSS entity.  
 
Expiry Event 
 
On  first  expiry  of  the  timer,  the  BSS  entity  retransmits  the  Blocking 
message.  In  case  of  a  second  expiry,  the  channel  is  set  to  non‐usable 
without MSC acknowledgment. 
 
The vendor based values for this timer are given below for reference 

  Motorola   Alcatel   Huawei 


T1  20 sec  16 sec  30 sec 

22
Mobilink Confidential Property 

6.2   CALL CLEARING 
 
  Once  a  call  is  ended,  the  resources  that  were  dedicated  to  it  now 
need  to  be  torn  down  so  that  they  may  be  reused  by  other  users.  This 
process is called call clearing. This section describes the timers used in call 
clearing 
 
6.2.1 T13 
 
Category  
 
This timer is used in the Reset Procedure initiated by the MSC. 
 
Start Event 
 
The timer starts when a Reset message is sent by the MSC to the BSS entity. 
 
Stop Event  
 
The timer stops on when the MSC receives Reset Acknowledgement by the 
BSS entity.   
 
Expiry Event 
 
In case of expiry event, the Reset acknowledgment is sent by the BSS to the 
MSC. 
 
The vendor based values for this timer are given below for reference 

  Motorola   Alcatel   Huawei 


T13  40 sec  15 sec  150 sec 
 
 

23
Mobilink Confidential Property 

6.2.2 T3111 
 
Category  
 
This timer is included in the Call release procedure which includes releasing 
of TCH channels 
 
Start Event 
 
This timer starts with the reception of Release indication message from the 
BSS entity. 
 
Stop Event  
 
The  timer  stops  when  the  BSS  entity  sends  the  message  for  RF  channel 
release to the respective BTS.  
 
Expiry Event 
 
The  expiry  of  this  timer  causes  the  forced  channel  release  procedure  to 
start and the channel is released from all ends of the network. 
 
 
The vendor based values for this timer are given below for reference 
 

  Motorola   Alcatel   Huawei 


T3111  1.5 sec  0.5  1.5 
 
 
 
 
 
 
 

24
Mobilink Confidential Property 

6.2.3 T3109 
 
Category  
 
This timer is included in the Call release procedure which includes releasing 
of TCH channels 
 
Start Event 
 
This  timer  starts  when  the  channel  release  message  is  sent  by  the  BSS 
entity to the subsequent BTS.  
 
Stop Event  
 
The  timer  is  stopped  when  the  release  indication  message  is  received  by 
the BSS entity. 
 
Expiry Event 
 
In case of an expiry event of this timer, the channels are released and call 
procedure is aborted. 
 
 
The vendor based values for this timer are given below for reference 

  Motorola   Alcatel   Huawei 


T3109  15 sec  12 sec  15 sec 
 

 
 

25
Mobilink Confidential Property 

6.2.4 T3110 
 
Category  
 
This timer is included in the Call release procedure which includes releasing 
of TCH channels 
 
Start Event 
 
This timer starts when the MS receives the Channel release message from 
the BSS entity. 
 
Stop Event  
 
The  timer  stops  once  the  MS  receives  a  layer  ‐2‐message  from  the  BSS 
entity for channel release. 
 
Expiry Event 
 
In case the timer expires, the normal channel release continues till the call 
is released. 
 
 
The default value for this timer is 10 seconds 

This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is 
unavailable.  

26
Mobilink Confidential Property 

6.3   HANDOVER 
This section deals with timers that essentially make up the handover 
procedure. Like call processing, a ladder diagram for handover is also given 
below for the ease of the reader. 
 
Details  for  each  of  the  mentioned  timers  will  follow  along  with 
suitable information on them. 

 
 
 
 
 
 
 

27
Mobilink Confidential Property 

6.3.1  T3103 
 
Category  
 
This timer is used in the Handover Procedure. 
 
Start Event 
 
The timer starts when the initiate Handover command is sent to the BTS by 
the BSC.  
 
Stop Event  
 
The Timer is stopped when handover complete message is received by the 
BSS entity.  
 
Expiry Event 
 
In  case  the  timer  expires,  the  handover  procedure  is  aborted  and  the 
Handover attempt is termed as unsuccessful. 
 
 
The vendor based values for this timer are given below for reference 

  Motorola   Alcatel   Huawei 


T3103  30 sec  16.5 sec  30 sec 
 
 
 
 
 
 

28
Mobilink Confidential Property 

6.3.2  T8 
 
Category  
 
This timer is used in the Handover Procedure. 
 
Start Event 
 
The timer starts when the Handover command is sent to the MS via the BSS 
entity. 
 
Stop Event  
 
The Timer is stopped when handover complete message is received by the 
BSS entity.  
 
Expiry Event 
 
In  case  the  timer  expires,  the  handover  procedure  is  aborted  and  the 
Handover attempt is termed as unsuccessful. 
 
 
The vendor based values for this timer are given below for reference 

  Motorola   Alcatel   Huawei 


T8  28 sec  14 sec  28 sec 

Note: If the value of T8 timer is set greater than the value of T3103, this could lead to 
potential  masking  of  Out_Intra_BSS_HO_LostMS  in  Intra  BSS  HOs  & 
Out_Inter_BSS_HO_Return, Out_Inter_BSS_Equip_Fail in Inter BSS HOs. 

29
Mobilink Confidential Property 

 
6.3.3 T7 
 
 
Category  
 
This timer is used in the Handover Procedure. 
 
Start Event 
 
The timer starts when a Handover Request message is sent to the MSC for 
an external BSC handover. 
 
Stop Event  
 
The Timer is stopped when handover response message is received by the 
BSS entity.  
 
Expiry Event 
 
In  case  the  timer  expires,  the  handover  procedure  is  aborted  and  the 
Handover attempt is termed as unsuccessful. 
 
 
The vendor based values for this timer are given below for reference 

  Motorola   Alcatel   Huawei 


T7  10 sec  5 sec  10 sec 

30
Mobilink Confidential Property 

6.3.4 TQHO 
 
Category  
 
This timer defines the maximum Queuing time for a Handover request. 
 
Start Event 
 
The  timer  starts  when  the  BSS  places  a  Handover  request  in  the  resource 
queue for allocation. 
 
Stop Event  
 
The timer is stopped when the Handover request is allocated the required 
resource by the BSS entity. 
 
Expiry Event 
 
In  case  of  an  expiry  event  of  this  timer,  the  handover  request  is  removed 
from the queue and the handover procedure is aborted. 
 
The vendor based values for this timer are given below for reference 

  Motorola   Alcatel   Huawei 


TQHO  30 sec  5 sec  8 sec 

 
 

31
Mobilink Confidential Property 

6.3.5 T3121 
 
Category  
 
This timer IS related with inter BSC and 2G/3G handovers. 
 
Start Event 
 
The  timer  is  started  when  a  request  is  sent  for  an  inter‐BSC  or  2G/3G 
handover.  
 
Stop Event  
 
The  timer  is  stopped  when  a  Handover  complete  message  is  received  by 
the BSS entity. 
 
Expiry Event 
 
In  case  of  an  expiry  event  of  this  timer,  Clear  request  is  sent  and  the 
handover procedure is aborted. 
 
The vendor based values for this timer are given below for reference 

  Motorola   Alcatel   Huawei 


TQHO  N‐A  14 sec  10 sec 

32
Mobilink Confidential Property 

6.4   GPRS TIMERS 

 
6.4.1   T3182 
 
Category  
 
This  is  an  MS  Based  Timer  and  it  is  concerned  with  the  RLC  Window  and 
stalling of TBF.   
 
Start Event 
 
If the RLC transmit window is filled with transmitted blocks and any of them 
is unacknowledged, then the TBF window stalls and no more blocks can be 
set. At this time, T3182 is started.  
 
Stop Event  
 
The  timer  stops  once  the  acknowledgment  for  all  the  transmitted  blocks 
has been received.  
 
Expiry Event 
 
If the timer expires, then another timer N3102 is decremented. The Radio 
resources  are  released  and  the  Mobile  station  tires  to  reestablish  the  TBF 
with the same cell through packet channel request.  
 

33
Mobilink Confidential Property 

6.4.2   T3164 
 
Category  
 
This is an MS based timer which is concerned the access procedures during 
GPRS connections. 
 
Start Event 
 
MS  access  the  network  for  a  GPRS  connection  through  the  Packet  data 
request. The BTS send the packet uplink assignment message through the 
USF access. The timer will start on reception of this assignment message.  
 
Stop Event  
 
The timer will stop once the USF uplink access has also been granted on the 
downlink.  
 
Expiry Event 
 
If the timer expires, and the access has not been granted on the downlink, 
then the radio resources will be released and the Mobile station will repeat 
the whole procedure from the packet data request message.  
 
 
 
 
 
 
 
 
 
 
 
 

34
Mobilink Confidential Property 

6.4.3  T3198 
 
Category  
 
This  is  an  MS  based  timer  which  is  concerned  the  acknowledgement  of 
transmitted RLC Blocks 
 
Start Event 
 
When  a  RLC  block  is  transmitted  by  the  Mobile  station,  Timer  T3198  is 
started. 
 
Stop Event  
 
The  timer  is  stopped  when  the  acknowledgment  of  the  transmitted  RLC 
block is received by the Mobile station.  
 
Expiry Event 
 
If  the  timer  expires  with  no  acknowledgment  for  the  transmitted  blocks, 
the RLC blocks is tagged as NACK in the MS.  
 

35
Mobilink Confidential Property 

6.4.4   T3180 
 
Category  
 
This timer is related with the dynamic allocation of Uplink TBF in the GPRS 
connection. 
 
Start Event 
 
This timer is started during the dynamic allocation of the Uplink TBF. When 
the last block is sent as permitted by the USF granularity, the Timer 3180 is 
started with this transmission. 
 
Stop Event  
 
When the USF is received in the downlink by the MS, this timer is stopped. 
 
Expiry Event 
 
In  case  the  timer  expires,  the  MS  abandons  the  TBF  and  the  access 
procedure is repeated with the same cell. 

36
Mobilink Confidential Property 

6.4.5   T3190 
 
Category  
 
This timer is related with the downlink assignment of Packet Data. 
 
Start Event 
 
The timer is started when the Mobile station receives the downlink packet 
data assignment from the BSS entity.  
 
Stop Event  
 
The timer is stopped when the Mobile station receives the downlink block 
containing the allocated TFI.  
 
Expiry Event 
 
In  case  the  timer  expires,  the  mobile  station  releases  the  radio  resources 
and aborts the TBF connection. In addition to this, the Mobile station starts 
monitoring the Common Control Packet channel. 

37
Mobilink Confidential Property 

6.4.6  T3192 
 
Category  
 
This timer is concerned with the release of Packet Data Channel 
 
Start Event 
 
The timer is started when the last block of downlink TBF is received.  
 
Stop Event  
 
If a message for forced release of Packet Data channel is received, the timer 
is stopped.  
 
Expiry Event 
 
When  the  timer  expires,  the  radio  resources  are  released  and  the  packet 
data session comes to an end. It is to be noted that the value of this timer is 
smaller than T3193, in order to make it sure that the TFI of this MS is not 
allocated to any other MS in the mean time. 

38
Mobilink Confidential Property 

6.4.7   T3200 
 
Category  
 
This Timer is related with the partitioned transmission of the RLC Blocks.  
 
Start Event 
 
In the partitioned transmission of RLC blocks, the RLC frames are dived into 
segments  with  each  segment  having  its  own  RTI  (Radio  Transaction 
Indicator). If the one of the segment is not received with its subsequent RTI, 
timer T3200 is started.  
 
Stop Event  
 
The  timer  is  stopped  when  the  correct  segment  with  the  following  RTI  is 
received.  
 
Expiry Event 
 
In case the time expires and the correct RTI has not been received, then the 
whole control block is rejected as a one or more segments are missing. 

39
Mobilink Confidential Property 

6.4.8  T3162 
 
Category  
 
This  timer  is  concerned  with  the  queuing  procedure  employed  during  the 
packet data access.  
 
Start Event 
 
The  timer  is  started  when  the  MS  receives  the  Packet  Queue  Notification 
from  the  BSS  entity.  This  message  is  in  response  to  the  Packet  access 
message.  
 
Stop Event  
 
The  timer  is  stopped  in  case  of  a  packet  assignment  message  or  packet 
accesses reject method.  
 
Expiry Event 
 
If  the  timer  expires  without  any  assignment  or  reject  message,  the  access 
procedure  is  aborted  and  the  mobile  monitors  the  Packet  data  common 
control channel. 

40
Mobilink Confidential Property 

6.4.9  T3168 
 
Category  
 
This  timer  is  concerned  with  acquisition  of  TBF  resources  during  a  Packet 
Data session.  
 
Start Event 
 
This timer starts when a packet data request is sent by the Mobile station 
for more data resources during a TBF session.  
 
Stop Event  
 
The Timer is stopped when the assignment message is received for the new 
uplink resource of TBF. 
 
Expiry Event 
 
In case the timer expires, the request of Packet Data resources is resent by 
the Mobile Station. 

41
Mobilink Confidential Property 

6.4.10   T3170 
 
Category  
 
This timer determines the time span for which the Mobile station will wait 
after sending the allowed number of Packet Data requests. 
 
Start Event 
 
The timer starts when the last of the allowed Packet Data Request is sent 
by the Mobile station to the BSS entity.  
 
Stop Event  
 
The timer is stopped when the Mobile station receives the uplink resources 
assignment message from the BSS entity.  
 
Expiry Event 
 
In  case  the  timer  expires,  the  access  procedure  is  aborted  and  the  upper 
layers are informed as well.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

42
Mobilink Confidential Property 

6.4.11  T3172 
 
Category  
 
This  Timer  is  concerned  with  the  wait  time  used  for  re‐transmitting  the 
access request for Packet Data.  
 
Start Event 
 
The  timer  begins  with  the  Packet  Assignment  Reject  method  and  this 
message also contains the amount of time, the timer has to remain active.  
 
Stop Event  
 
The  timer  is  stopped  when  the  Packet  Assignment  message  is  received  in 
response to the access request.  
 
Expiry Event 
 
In  case  the  timer  expires,  a  request  of  Packet  Data  resources  is  resent  by 
the Mobile Station. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

43
Mobilink Confidential Property 

6.4.12   T3176 
 
Category  
 
This  timer  is  concerned  with  the  signaling  for  cell  change  failure  during 
packet data session. 
 
Start Event 
 
The timer is started when the first message for cell change failure is sent to 
the BSS entity.  
 
Stop Event  
 
The timer is stopped if a successful cell change occurs and the confirmation 
message is sent to the Mobile station. .  
 
Expiry Event 
 
In case the timer expires, the signaling for the failed cell changes is stopped 
and the Mobile station returns to normal operation.
 
 
 
 
 
 

44
Mobilink Confidential Property 

6.4.13   T3188 
 
Category  
 
This timer is used for the fixed allocation of uplink TBF. 
 
Start Event 
 
The timer is started when the Mobile station sends a request to BSS entity 
regarding access for the fixed uplink TBF. .  
 
Stop Event  
 
The  timer  is  stopped  once  the  Mobile  station  receives  the  assignment 
message for the uplink resource.  
 
Expiry Event 
 
In case the timer expires, the request for the resources is re‐sent. 

45
Mobilink Confidential Property 

6.4.14  T3322 
 
Category  
 
This timer is involved in the Detach process in the Packet Data connection. 
 
Start Event 
 
The timer is started when the detach request is sent by the Mobile station 
to the BSS entity. 
 
Stop Event  
 
The  timer  is  stopped  when  the  Mobile  station  receives  the  Detach  accept 
message from the BSS entity.  
 
Expiry Event 
 
In  case  the  timer  expires,  the  detach  request  is  resent  by  the  Mobile 
station.  
 

46
Mobilink Confidential Property 

6.4.15   T3380 
 
Category  
 
This timer is used in the PDP Context activation procedure.  
 
Start Event 
 
The  timer  is  started  when  the  Mobile  station  sends  the  request  for  PDP 
context activation.  
 
Stop Event  
 
The timer is stopped when the BTS entity sends the confirmation message 
for the attach procedure.  
 
Expiry Event 
 
In  case  the  timer  expires,  the  request  for  PDP  context  is  resent  by  the 
Mobile station.  

47
Mobilink Confidential Property 

6.4.16   T3385 
 
Category  
 
This timer is used in the PDP Context activation procedure.  
 
Start Event 
 
The timer is started when the network sends the request for start of data 
session to the SGSN. 
 
Stop Event  
 
The timer is stopped when the SGSN entity sends the confirmation message 
for the start of data connection.  
 
Expiry Event 
 
In  case  the  timer  expires,  the  request  for  data  session  is  resent  by  the 
network.  

48
Mobilink Confidential Property 

6.4.17   T3386 
 
Category  
 
This timer is used in the PDP Context modification procedure.  
 
Start Event 
 
The timer is started when the network sends the request for modification 
of PDP context to the MS.  
 
Stop Event  
 
The  timer  is  stopped  when  the  network  receives  the  response  of  the 
modification message. 
 
Expiry Event 
 
In  case  the  timer  expires,  the  request  for  modification  for  PDP  Context  is 
resent by the network.  

49
Mobilink Confidential Property 

6.4.18   T3390 
 
Category  
 
This timer is used in the PDP Context deactivation procedure.  
 
Start Event 
 
The timer is started when the MS sends the request for deactivation of PDP 
context to the network.  
 
Stop Event  
 
The  timer  is  stopped  when  the  MS  receives  the  Deactivation  accept 
message from the network.  
 
Expiry Event 
 
In  case  the  timer  expires,  the  request  for  deactivation  for  PDP  Context  is 
resent by the MS.  

50
Mobilink Confidential Property 

6.4.19   T3395 
 
Category  
 
This timer is used in the PDP Context deactivation procedure.  
 
Start Event 
 
The  timer  is  started  when  the  GPRS  Sub  network  sends  the  request  for 
deactivation of PDP context to the network.  
 
Stop Event  
 
The timer is stopped when the GPRS Sub network receives the Deactivation 
accept message from the network.  
 
Expiry Event 
 
In  case  the  timer  expires,  the  request  for  deactivation  for  PDP  Context  is 
resent by the GPRS sub network.  

51
Mobilink Confidential Property 

6.4.20   T3158 
 
Category  
 
This timer relates to Period between measurement reports. The 
Measurement reports may be made in packet idle mode or packet transfer 
mode, the timer being set by NC_REPORTING_PERIOD_I (packet idle) or 
NC_REPORTING_PERIOD_T (transfer). 
 
 
Start Event 
 
Sending of previous measurement report. 
 
Stop Event  
 
None 
 
Expiry Event 
 
Next measurement report sent. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

52
Mobilink Confidential Property 

6.4.21   T3166 
 
Category  
 
This timer is the One‐phase access contention timer 
 
 
Start Event 
 
When the first RLC/MAC block is transmitted 
 
 
Stop Event  
 
when a packet uplink ack/nack returning TLLI is received 
 
Expiry Event 
 
On expiry, the mobile station must stop transmitting and  
disconnect from the radio resources. A contention failure or other failure 
has occurred. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

53
Mobilink Confidential Property 

6.4.22  T3169 
 
Category  
 
Response to USF tolerance timer 
 
Start Event 
 
N3101 reaches its allowed maximum count, N3101_MAX. 
 
Stop Event  
 
None 
 
Expiry Event 
 
On expiring, the USF is released (which means it can be reassigned to 
another mobile station). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

54
Mobilink Confidential Property 

6.4.23   T3174 
 
Category  
 
Handover (cell change order) failure timer 
 
Start Event 
 
When the GPRS sub‐network is in command of cell selection, it may tell the 
mobile station to change to another cell with packet cell change order. This 
command starts T3174 and the mobile station changes physical channels, 
sending a packet channel request to the new cell. 
 
Stop Event  
 
When a packet uplink assignment is received from the new cell. 
 
Expiry Event 
 
Handover or cell change has failed and T3176 starts. 

55
Mobilink Confidential Property 

6.4.24   T3182 
 
Category  
 
Window stall timeout for dynamic allocation 
 
Start Event 
 
When the RLC transmit window k is filled with transmitted RLC/MAC blocks, 
any one of which is unacknowledged, then the TBF window ‘stalls’ and no 
more blocks can be sent. T3182 is then started. 
 
Stop Event  
 
Packet uplink acknowledge reception from the GPRS sub‐network, allowing 
the window to be advanced and transmissions to be resumed. 
 
Expiry Event 
 
N3102 is decremented (by the amount PAN_DEC sent in packet system 
information), disconnects from the radio resources and attempts to re‐
establish the TBF in the same cell with packet channel request.  
 
 
 

56
Mobilink Confidential Property 

6.4.25   T3178 
 
Category  
 
Packet idle mode extended measurement report period 
 
The value of this timer is contained in the idle mode extended 
measurement reports command contained in PSI5 or PCCCH. The mobile 
station will report measurements with this periodicity. 
 
Start Event 
 
N/A 
 
Stop Event  
 
N/A 
 
Expiry Event 
 
N/A 
 
 
 

57
Mobilink Confidential Property 

6.4.26   T3184 
 
Category  
 
Fixed allocation packet uplink ack/nack tolerance timer 
 
Start Event 
 
Receipt of packet uplink ack/nack. 
 
 
Stop Event  
 
Receipt of the next packet uplink ack/nack. 
 
 
Expiry Event 
 
Mobile station releases the TBF and radio resources. 
 
 
 

58
Mobilink Confidential Property 

6.4.27   T3191 
 
Category  
 
Response to final data block tolerance timer 
 
Start Event 
 
Transmission of the final RLC data block in a downlink TBF 
 
Stop Event  
 
Receipt of packet downlink ack/nack or packet control ack 
 
Expiry Event 
 
TFI and other resources are released. 
 
 
 

59
Mobilink Confidential Property 

6.4.28   T3193 
 
Category  
 
Uplink RLC release timer. This is the network counterpart of T3192. This 
timer must be longer than T3192. 
 
 
Start Event 
 
(See T3192) 
 
Stop Event  
 
(See T3192) 
 
Expiry Event 
 
(See T3192) 
 
 

60
Mobilink Confidential Property 

6.4.29   T3195 
 
Category  
 
Linked to TBF and TFI 
 
Start Event 
 
T3195 starts when N3105 reaches to maximum value 
 
Stop Event  
 
N/A 
 
Expiry Event 
 
The network releases TFI resource 
 
 

61
Mobilink Confidential Property 

6.4.30  T3310 
 
Category  
 
Attach request timer 
 
Start Event 
 
When attach request is sent. 
 
Stop Event  
 
Attach accept is received. 
 
Expiry Event 
 
Attach request message is resent. 
 
 
 

62
Mobilink Confidential Property 

6.4.31   T3312 
 
Category  
 
Periodic routing area update 
 
Determines when the mobile station GMM function will perform an 
automatic RA update (irrespective of whether the RA has changed). 
 
 
Start Event 
 
N/A 
 
Stop Event  
 
N/A 
 
Expiry Event 
 
N/A 
 
 

63
Mobilink Confidential Property 

6.4.32   T3314 
 
Category  
 
Ready timer 
 
This timer specifies the maximum time that the mobile station is allowed to 
remain in GMM ready condition without an LLC PDU transfer with the GPRS 
sub‐network. 
 
 
Start Event 
 
Sending of an LLC PDU to the GPRS sub‐network 
 
Stop Event  
 
Sending of an LLC PDU to the GPRS sub‐network 
 
Expiry Event 
 
Mobile station is forced to GMM standby. 
 
 
 

64
Mobilink Confidential Property 

6.4.33   T3321 
 
Category  
 
GPRS sub‐network detach timer 
 
Start Event 
 
Sending of detach request 
 
Stop Event  
 
Reception of detach accept. 
 
Expiry Event 
 
Mobile station resends the detach request 

65
Mobilink Confidential Property 

6.5   MISCELLANEOUS 
 
 
6.5.1 T3128 
 
Category  
 
This  timer  is  related  with  the  access  procedure  of  Uplink  investigation 
process.  
 
Start Event 
 
The  timer  starts  when  the  uplink  busy  message  is  sent  to  the  MS  upon 
receiving access request for uplink investigation. 
 
Stop Event  
 
The timer is stopped when Uplink free message is sent to the MS. 
 
Expiry Event 
 
In case of an expiry event of this timer, the Uplink investigation process is 
aborted. 
 

The default value for this timer is 1 second.

This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is 
unavailable.  

 
 

66
Mobilink Confidential Property 

6.5.2 T3210 
 
Category  
 
This timer is related with the access procedure of Location Update. 
 
Start Event 
 
The timer starts when the MS sends the location update request to the BSS 
entity.  
 
Stop Event  
 
The timer is stopped when the Location_update_accept or reject message 
is  received  by  the  MS  entity.  This  timer  is  also  stopped  in  case  of  a  lower 
layer failure. 
 
Expiry Event 
 
In case of an expiry event of this timer, the BSS timer T3211 is started. 
 
The default value for this timer is 20 seconds.

This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is 
unavailable.  

67
Mobilink Confidential Property 

6.5.3 T3211 
 
Category  
 
This  timer  is  related  with  the  access  procedure  of  location  update 
procedure. 
 
Start Event 
 
This  timer  starts  when  location_update_reject  is  received  with  the  cause 
value indicating network failure. 
 
Stop Event  
 
The Timer is stopped when the location update takes place or cell for the 
particular MS is changed. 
 
Expiry Event 
 
In case this timer expires, the  request for location  update is  again sent to 
the BSS entity. 
 

The default value for this timer is 15 seconds.

 
 
 

68
Mobilink Confidential Property 

6.5.4 T3212 
 
Category  
 
This timer is related with the termination of MM signaling. 
 
Start Event 
 
This timer starts with the termination of MM signaling.  
 
Stop Event  
 
The timer stops when the message for the initiation of MM signaling is sent 
to the MS by the BSS entity.  
 
Expiry Event 
 
In case the timer expires, a periodic request is sent for the LU update.  

The default value for this timer is 60 seconds.

This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is 
unavailable.  

69
Mobilink Confidential Property 

6.5.5 T3220 
 
Category  
 
This timer is related with the IMSI detach procedure. 
 
Start Event 
 
The  timer  starts  when  the  MS  sends  an  IMSI  detach  message  to  the  BTS 
entity.  
 
Stop Event  
 
The timer is stopped when the MS is removed from the MM sub‐layer.  
 
Expiry Event 
 
In case the timer expires, the MS enters the Null period and request is sent 
for the status to be updated.  

The default value for this timer is 5 seconds.

This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is 
unavailable.  

70
Mobilink Confidential Property 

7.0    VENDOR BASED COMPILED LISTS 
 
7.1    MOTOROLA TIMERS
 
Timers 
T_hand_rqd   T3230 
T_HAND_RQD   T3240 
T_SDCCH_HO_ALLOWED  T4 
t_stat_info   T4 (ITU)  
T1   T4_TIMER  
T1 (ITU)  T4_TIMER (Lb interface)  
T1_TIMER   T4_TIMER_ID (Lb interface)  
T1_TIMER (Lb interface)   T5 
T1_TIMER_ID (Lb interface)   T5 (ITU)  
T12   T5_TIMER  
T12_TIMER  T5_TIMER (Lb interface)  
T12_TIMER (Lb interface)   T5_TIMER_ID (Lb interface)  
T13   T6 
T13_TIMER  T6 (ITU)  
T13_TIMER (Lb interface)   T6_TIMER_ID (Lb interface)  
T14   T7  
T14_TIMER  T7 (ITU)  
T14_TIMER (Lb interface)   T7_EXP‐MSG_TYPE  
T17   T7_TIMER_ID (Lb interface)  
T17_TIMER   TCH assignment‐successful  
T17_TIMER (Lb interface)   TCH assignment‐unsuccessful  
T2  TCONN_EST  
T2 (ITU)   Tqho 
T2_TIMER   TREL 
T2_TIMER (Lb interface)   bssgp_t1_timer  
T2_TIMER_ID (Lb interface)   bssgp_t2_timer  
T22   bssgp_t5_timer  
T22_TIMER   bssmap_t1  
T22_TIMER (Lb interface)   bssmap_t10  
T23   bssmap_t11  
T23_TIMER   bssmap_t13  
T23_TIMER (Lb interface)   bssmap_t19  
T3  bssmap_t20 
T3 (ITU)   bssmap_t4  
T3_TIMER_ID (Lb interface)   bssmap_t7  
T3101   bssmap_t8  
T3103   bssmap_tqho  
T3105   bounce_protect_cong_tmr  
T3109   bounce_protect_qual_tmr  
T3111   bts_p_con_timer 
T3122   CLM_T1  
T3210   CLM_T13  
T3212   CLM_T19  
T3220  CLM_T20  

71
Mobilink Confidential Property 

Timer 
CLM_T4   rr_t3111  
hop_count_timer  rr_t3111_sd  
lb_int_ss7_l2_t1   rr_t3111_tch  
lb_int_ss7_l2_t2   rr_t3212  
lb_int_ss7_l2_t3   RRSM_AUDIT_TIMER  
lb_int_ss7_l2_t4   RRSM_T10  
lb_int_ss7_l2_t5   RRSM_T11  
lb_int_ss7_l2_t6   RRSM_T8  
lb_int_ss7_l2_t7   ss7_l2_t1  
lb_int_ss7_l3_t1   ss7_l2_t2  
lb_int_ss7_l3_t12  ss7_l2_t3  
lb_int_ss7_l3_t13  ss7_l2_t4  
lb_int_ss7_l3_t14  ss7_l2_t5  
lb_int_ss7_l3_t17  ss7_l2_t6  
lb_int_ss7_l3_t2   ss7_l2_t7  
lb_int_ss7_l3_t22   ss7_l3_t1  
lb_int_ss7_l3_t23   ss7_l3_t12  
lb_int_ss7_l3_t4   ss7_l3_t13  
lb_int_ss7_l3_t5   ss7_l3_t14  
lb_int_ss7_slt_t1   ss7_l3_t17  
not aligned timer   ss7_l3_t2  
ns_alive_timer   ss7_l3_t22  
ns_block_timer   ss7_l3_t23  
ns_reset_period   ss7_l3_t4  
ns_reset_timer   ss7_l3_t5  
ns_test_timer   wait for clear command from the BSS‐based SMLC timer  
penalty_time   wait for SCCP release complete timer  
PENALTY_TIME   wait for SCCP released message from SMLC timer  
PERF_LOC_TIMER   wait_for_reselection  
rr_ny1_rep   wait_indication_parameters  
rr_t3101  waiting for changeback acknowledgement (rst attempt) timer  
rr_t3103   waiting for changeback acknowledgement (second attempt) timer  
rr_t3105   waiting for changeover acknowledgement timer  
rr_t3109   waiting for force uninhibit timer 
to 3‐62, 3‐210, 3‐212, 3‐214, 3‐10  waiting for inhibition acknowledgement timer  
rr_t3110  add_access_class 
rf_chan_rel_ack  sccp_tconn_est 
retry_cand_period  radiochanrel 
exrtrycandprd  sccp_released 
validcandperiod  assign_successful 
radio_link_timeout  bsc_audit 
link_fail  bsc_audit_response 
linkabouttofail  clear_command 
channel_act  clear_cmd_ext_ho 
channel_teardown  circuit_reset_ack 
cipher_comp_ms  ciphering_successful 
ho_complete  ext_ho_allocation 
mode_modify  ho_allocation 
modeRRModifyAck  ho_request 
register_exp  ho_successful 

72
Mobilink Confidential Property 

7.2    ALCATEL TIMERS 
 
Timer   Entity  Timer  Entity 
T(conn est)  BSC  T_GSL_ACK (BSC)  BSC 
T(iar)  BSC  T_HO_REQD_LOST  BSC 
T(sst)  BSC  T_INHIBIT_CPT  BSC 
T_ALLOC_BTS  BSC  T_LB_OV  BSC 
T_AVG_T (MFS)  MFS  T_LCS_RESTART (BSC)  BSC 
T_BA_CHANGE  MFS  T_Location  BSC 
T_BTS_RLS_CNF  BSC  T_MAX_FOR_MS_SYNCHRO  MFS 
T_CBC_READY  BSC  T_MAX_STREAMING_BUFFERING  MFS 
T(ias)  BSC  T_MS_CELL_REJ  BSC 
T_ACK_WAIT  MFS  T_NC_PING_PONG  MFS 
T_AUTOCLEANING_MEAS_REP  BSC  T_NC2_LOAD_RANKING  MFS 
T_AVG_W (BSC)  BSC  T_One_Block  MFS 
T_BIND_CNF  BSC  T_COUNT_I  BSC 
T_BURST  BSC  T_DELAY_GSL  BSC 
T_CFI_TR  BTS  T_DELAYED_DL_TBF_POL_INITIAL  MFS 
T(rel)  BSC  T_dl_assign_ccch  MFS 
T_ACK_WAIT_DRX_PCCCH  MFS  T_DSP_LOAD_REPORT  MFS 
T_AVG_T (BSC)  BSC  T_EXTENDED_UL_TBF_POL  MFS 
T_AVG_W(MFS)  MFS  T_flow_ctrl_cell  MFS 
T_BTS_EST_CNF  BSC  T_GCH_INACTIVITY_LAST  MFS 
T_CANDIDATE_TBF_REALLOC  MFS  T_GSL_ACK (MFS)  MFS 
T_CHANGE_RLC_MODE  MFS  T_i  BSC 
T_CONFIG_TBF  MFS  T_INITIAL_PDCH  MFS 
T_DELAY  BSC  T_LCS_Delay_Tolerant  MFS 
T_DELAY_PAGING_EXT  MFS  T_LCS_RESTART (MFS)  MFS 
T_Delayed_DL_TBF_Pol_UL  MFS  T_Location_Longer  BSC 
T_DL_EGPRS_MeasReport  MFS  T_MAX_FOR_TBF_SCHEDULING  MFS 
T_DTM_ASSIGN  MFS  T_MIN_POLL  MFS 
T_FAST_DL_margin  MFS  T_MS_CONTEXT_FLUSH_PERSISTENCE  MFS 
T_flow_ctrl_ms  MFS  T_NC_REJ_CELL  MFS 
T_GPRS_Resume  BSC  T_NETWORK_RESPONSE_TIME  MFS 
T_HCP  BSC  T_OVL_MSC  BSC 
T_IA  BSC  T_PAG_CS (BSC)  BSC 
T_INTRF_L3  BSC  T_PAG_PS (MFS)  MFS 
T_LCS_Low_Delay  MFS  T_PDA  BSC 
T_Loc_abort  BSC  T_PUA  BSC 
T_MAX_EXTENDED_UL  MFS  T_RECOVERY  BSC 
T_MAX_RETRANS_DL  MFS  T_REPETITION_UPLINK_FREE  BSC 
T_MPDCH_EST_PROC (BSC)  BSC  T_RESET_COUNTER  BTS 
T_MS_Context_Lifetime  MFS  T_RMS_BSC_RESTART  BSC 
T_NC_RXQUAL_VALID  MFS  T_RRLP_Low_Delay  MFS 
T_NOTIF_RESPONSE_DELAY  BSC  T_SHARED_DTM_INFO (BSC)  BSC 
T_CONNECT  BSC  T_SMSCB_RESP  BSC 
T_delay_gch  MFS  T_SYNC  BTS 
T_DELAYED_DL_TBF_POL  MFS  T_ta  BTS 
T_DELAYED_FINAL_PUAN  MFS  T_TFO  BSC 
T_DL_GPRS_MeasReport  MFS  T_ul_assign_pccch  MFS 
T_DYN_SDCCH_HOLD  BSC  T_WAIT_CS_PROC  MFS 

73
Mobilink Confidential Property 

Timer   Entity  Timer  Entity 


T_FILTER  BSC  T_WAIT_PMR_MARGIN  MFS 
T_GCH_INACTIVITY  MFS  T1_0858  BSC 
T11  BSC  T3168 (BSC)  BSC 
T_PAG_CS (MFS)  MFS  T3180  MFS 
T_PAGING_EXT  MFS  T3191  MFS 
T_PSCD_SCHEDULE_ACK  MFS  T3208n  MFS 
T_qho  BSC  T391  MFS 
T_release  TC  T7  BSC 
T_REROUTING_REQUEST_GUARD  MFS  T17  BSC 
T_RMS_BSC  BSC  T19  BSC 
T_RMS_BTS  BSC  T200 (BSC)  BSC 
T_SAGI_GUARD  MFS  T200_GSL (BSC)  BSC 
T_SHARED_DTM_INFO (MFS)  MFS  T200_S3  BTS 
T_STOP_FR_EMISSION  MFS  T200_TF  BTS 
T_SYNCd  BTS  T203 (BSC)  BSC 
T_TBF_ACTIV  MFS  T203_GSL (MFS)  MFS 
T_ul_access_max  MFS  T3105_D  BSC 
T_UL_CONGESTION  MFS  T3105_F_HR  BSC 
T_WAIT_DTM  MFS  T3106_D_STOP  BSC 
T_WAIT_UPLINK_ACCESS  BSC  T3107  BSC 
T1_long  BSC  T3115  BSC 
T11_FORCED  BSC  T3148n  BSC 
T_PAG_PS (BSC)  BSC  T3168 (MFS)  MFS 
T_PAGING_REORG  MFS  T3182n  MFS 
T_PSI_PACCH  MFS  T3192 (BSC)  BSC 
T_RCR_ACK  BSC  T3212(BSC)  BSC 
T_REPETITION_CHANNEL_RELEASE  BSC  T4  BSC 
T_RESEL  MFS  T8  BSC 
T_RMS_BSC_RECONF  BSC  T18  BSC 
T_RRLP_Delay_Tolerant  MFS  T2_0858  BSC 
T_SDCCH_PC  BSC  T200_D  BTS 
T_SMSCB_READY  BTS  T200_GSL (MFS)  MFS 
T_SUP  BTS  T200_SD  BTS 
T_SYNCu  BTS  T200_TH  BTS 
T_TBF_BCK_REL  MFS  T203 (BTS)  BTS 
T_ul_assign_ccch  MFS  T3101  BSC 
T_USF_Scheduling_AGCH  MFS  T3105_D_STOP  BSC 
T_WAIT_FLUSH  MFS  T3105_F_STOP  BSC 
T_WAIT_UPLINK_REQUEST_ACK  BSC  T3106_F  BSC 
T1_short  BSC  T3109  BSC 
T13  BSC  T3121  BSC 
T14  BSC  T3166n  MFS 
T18_Overload  BSC  T3169  MFS 
T20  BSC  T3190n  MFS 
T200_D3  BTS  T3192 (MFS)  MFS 
T200_OMU  BTS  T3212 (MFS)  MFS 
T200_ST  BTS  T5_RA_CAP_UPDATE  MFS 
T200_TRE  BTS  T9101  BSC 
T203_GSL (BSC)  BSC  T9103  BSC 

74
Mobilink Confidential Property 

Timer   Entity  Timer  Entity 


T3103  BSC  T9108  BSC 
T3105_F_FR  BSC  T9113  BSC 
T3106_D  BSC  T9104  BSC 
T3106_F_STOP  BSC  T9110  BSC 
T3111  BSC  T9105  BSC 
T3122  BSC  T9112  BSC 

75
Mobilink Confidential Property 

7.3    HUAWEI TIMERS 
 
Timers 
T200 SDCCH SAPI3(5ms)  PBGT Valid Time(s) 
T200 SACCH SDCCH(10ms)  PBGT Watch Time(s) 
T200 SACCH TCH SAPI3(10ms)  Layer HO Valid Time(s) 
T200 SACCH TCH SAPI0(10ms)  Layer HO Watch Time(s) 
T200 FACCH/H(5ms)  Edge HO AdjCell Valid Time(s) 
T200 FACCH/F(5ms)  Edge HO AdjCell Watch Time(s) 
T200 SDCCH(5ms)  Edge HO Valid Time(s) 
AHR Radio Link Timeout(SACCH period (480ms))  Edge HO Watch Time(s) 
AFR Radio Link Timeout(SACCH period (480ms))  Update Period of CH Record(min) 
AHR SACCH Multi‐Frames(SACCH period (480ms))  TCH Minimum Recovery Time(s) 
AFR SACCH Multi‐Frames(SACCH period (480ms))  Release Delay of Downlink TBF(ms) 
SACCH Multi‐Frames(SACCH period (480ms))  Inactive Period of Extended Uplink TBF(ms) 
TDD 3G Better Cell HO Valid Time(s)  Release Delay of Non‐extended Uplink TBF(ms) 
TDD 3G Better Cell HO Watch Time(s)  Cell Reselect Interval(s) 
Quick Handover Punish Time(s)  Cell Penalty Last Time(s) 
Quick Handover Last Time (0.5s)  Cell Reselection Forbidden Time 
Quick Handover Static Time(0.5s)  Non‐DRX Period 
Number of Satisfactory Measurements(s)  GPRS Penalty Time 
Total Number of Measurements(s)  Extension MR Period 
Inter UL And OL Subcells HO Penalty Time(s)  Max. Duration of DRX(s) 
OL Subcell Load Diversity HO Period(s)  T3192 
Modified Step Length of UL Load HO Period(s)  T3168 
UL Subcell Load Hierarchical HO Period(s)  Cell Reselection MR Period in Packet Transfer Mode 
3G Better Cell HO Valid Time(s)  Cell Reselection MR Period in Packet Idle Mode 
3G Better Cell HO Watch Time(s)  Timer for UL Data Forward(ms) 
Penalty Time after OtoU HO Fail(s)  WaitforRelIndAMRHR 
Penalty Time after UtoO HO Fail(s)  WaitforRelIndAMRFR 
Penalty Time of UtoO HO(s)  T3103C(ms) 
Underlay HO Step Period(s)  T3122(s) 
UO HO Valid Time(s)  TREESTABLISH(ms) 
UO HO Watch Time(s)  T3111(ms) 
Penalty on MS Fast Moving HO  T3109(ms) 
CfgPenaltyTimer  T8(ms) 
UmPenaltyTimer  T3121(ms) 
RscPenaltyTimer  T3107(ms) 
Penalty Time after AMR TCHF‐H HO Fail(s)  T7(ms) 
Penalty Time after TA HO(s)  T3103A(ms) 
Penalty Time after BQ HO(s)  ImmAss A Interf Creation Timer(ms) 
Min Interval for Consecutive HOs  T3101(ms) 
Min Interval for SDCCH HOs  Aiding Delay Protect Time(min) 
Min Interval for TCH HOs  CCCH Load Indication Period(s) 
TIGHT BCCH HO Valid Time(s)  Radio Resource Report Period(s) 
TIGHT BCCH HO Watch Time(s)  Frame Start Time 
Intracell F‐H HO Last Time(s)  Interf.Calculation Period(SACCH period(480ms)) 
Intracell F‐H HO Stat Time(s)  Speed Penalty Time 
 

76

You might also like