Technical Specifications

Technical Specifications
Wiring Diagrams – Switches & Receptacles

Switches
Single Pole Double Pole 3-Way to 3-Way 3-Way to 4-Way to 3-Way

Pilot Light Switch & Lighted Toggle Switch


Single Pole Single Pole Double Pole 3-Way 3-Way Pilot
Pilot Light Switch Lighted Toggle Switch Pilot Light Switch Lighted Toggle Lighted Toggle
Toggle Glows when Toggle Glows when Toggle Glows when Switch Switch
Light is On Switch is Off Switch is On (Two Lighted or Pilots May Be Used)

Maintained & Momentary Contact


Maintained Contact Momentary Contact Maintained Contact
3-Position, 2-Circuit Either Direction Either Direction
Center “Off” 3-Position, Center “Off” 2-Position, No Center “Off”

Single Pole Single Pole Single Pole


Double Throw Double Throw Double Throw

Double Pole Double Pole Double Pole


Double Throw Double Throw Double Throw

1222 1256 1276


Wiring Diagrams

Receptacles
1 Circuit Split Circuit 1 Circuit

U-13
Technical Specifications
Technical Specifications

Wiring Diagrams – GFCIs

GREEN OR UNINSULATED GROUNDING WIRE

Wiring Diagram GFCI Receptacle, Feed-Thru Installation

To protect the entire branch circuit the GFCI must be the first receptacle from the fuse or circuit
breaker box. Receptacles on the circuit between the GFCI and the box will not be protected,
but receptacles downstream from the GFCI will have protection.

NON-FEED-THRU APPLICATION ON 2 WIRE CIRCUIT

Wiring Diagram GFCI Receptacle, Non-Feed-Thru Installation

Terminal, or one-outlet-only protection can be achieved on a multi-outlet circuit by connecting


the hot and neutral line conductors to the corresponding line side terminals of the GFCI. Only
the GFCI receptacle will be protected.
Wiring Diagrams

U-14
Technical Specifications

Technical Specifications
Wiring Diagrams –
2 Pole, 2 Wire Non-Grounding
3 Pole, 3 Wire Non-Grounding
2 Pole, 2 Wire Non-Grounding

125V

250V

3 Pole, 3 Wire Non-Grounding

125V/250V

Wiring Diagrams

3ø250V

U-15
Technical Specifications
Technical Specifications

Wiring Diagrams –
2 Pole, 3 Wire Grounding
2 Pole, 3 Wire Grounding

125V

250V

277VAC

480VAC
Wiring Diagrams

U-16
Technical Specifications

Technical Specifications
Wiring Diagrams –
3 Pole, 4 Wire Grounding
3 Pole, 4 Wire Grounding

125V/250V

3ø250V

3ø480V

Wiring Diagrams

3ø600V

U-17
Technical Specifications
Technical Specifications

Wiring Diagrams –
4 Pole, 4 Wire Non-Grounding
4 Pole, 4 Wire Non-Grounding

3øY120V/208V

3øY277/480V

3ø347/600V
Wiring Diagrams

U-18
Technical Specifications

Technical Specifications
Wiring Diagrams –
4 Pole, 5 Wire Grounding
4 Pole, 5 Wire Grounding

3øY120V/208V

3øY277/480V

3øY347/600V

Wiring Diagrams

U-19
Technical Specifications
Technical Specifications

Wiring Diagrams –
Dimmers & Fan Speed Controls
Single-Pole Wiring Single-Pole Wiring Using 3-Way Preset Dimmer

3-Way Wiring

Control Line Side Control Load Side

3-Way 3-Way
Preset 3-Way 3-Way Preset
Switch Switch
Dimmer Dimmer
OR

4-Way Wiring
Control Line Side

OR
Wiring Diagrams

Control Load Side

U-20